Tahoma Terra 2 Apts Bld C LayoutSITE NITS CPVC HANGER CHART I&k�-11.1&=R f_1..I1.� AZf_lI— 0 5 20 SCALE IN FEET 13 T. SYSTEM FDC PIPING TO FDC IN YARD AT SIDEWALK v; 1.25" 1.25" / SPARE HEAD BOX N \CHECK VALVE WATER FLOW INDICATOR N DRAIN VALVE N Ut N PRESSURE GAUGE iv 14 N DRAIN PIPED TO EXTERIOR 1.25" AMES 2000B-FP BACKFLOW ---PREVENTER 15 I 2 N SPRINKLER RISER General Notes 16 8" WATER MAIN 1. OWNER TO PROVIDE ADEQUATE HEAT (407. MIN) TO PREVENT SPRINKLER PIPES FROM FREEZING. 2. CPVC PIPE SHALL HAVE HANGERS 6'-0" c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD. 3. ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING. GARAGE LEVEL PIPING TO BE REVERSE TENTED TO PREVENT FREEZING. 4. ALL PIPING TO BE 1" C.P.V.C. U.N.O. 5. FLOW SWITCH TO BE MONITORED BY OTHERS 6. A 8" BELL TO BE LOCATED ON THE FRONT APPROACH TO BUILDING. Sprinkler Symbol Legend both sheets total SYM SPRINKLER ORIFICE SIZE, TYPE & FINISH RELIABLE F1 RES 49 16'x16' RELIABLE F1 RES 49 16'x16' Reliable F 3 QR DRY Sidewall Reliable DH 56 DRY Sidewall 28'x10' QUAN TEMP IK FA( 195 155° 4.9 24 175' 4.9 24 155- 5.6 6 155- 5.6 TOTAL 1 249 1.25" 1.257' TO 3RD FLOOR/ 2N D FLOOR TO 3RD FLOOR/ FROM 1 st FLOOR FROM 1 st FLOOR SCALE 1/e•— 10-0" EVERGREEN RE PROTECTION INC. PO BOX 998 Puyallup, WA 98371 EVERGFP967LZ Phone: (253) 252-7942 Stamp WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE SPRINKLER SYSTEMS n Michael 0. Hutchinson E 1166-0599-BG Level Evergreen Fire Protection, Inc. EVERGFP fi7LZ Signature p re dx,rs eararef ra feemu miu fars.f �...-------, Sheet Title NFPA 13R FIRE PLAN Tchomc Terra 2 Apts. Ed C itle 143 01 TAHOMA BLVD SIE YELM9 WA 98597 DATE: 2/27/2025 REV: DRAWN: MH SHEET: 1 OF 2 S 1 TE NTS General Notes 1. OWNER TO PROVIDE ADEQUATE HEAT (40°F. MIN) TO PREVENT SPRINKLER PIPES FROM FREEZING. 2. CPVC PIPE SHALL HAVE HANGERS 6'-0" c\c AND NOT MORE THAN 6" FROM ANY SPRINKLER HEAD. 3. ALL ATTIC PIPING TO BE TENTED WITH BATT INSULATION TO PREVENT FREEZING. GARAGE LEVEL PIPING TO BE REVERSE TENTED TO PREVENT FREEZING. 4. ALL PIPING TO BE 1" C.P.V.C. U.N.O. 5. FLOW SWITCH TO BE MONITORED BY OTHERS 6. A 8" BELL TO BE LOCATED ON THE FRONT APPROACH TO BUILDING. 0 0 Sprinkler Symbol Legend both sheets total SYM SPRINKLER ORIFICE SIZE, TYPE & FINISH RELIABLE F1 RES 49 16'x16' RELIABLE F1 RES 49 16'x16' Reliable F 3 QR DRY Sidewall CPVC HANGER CHART 11V ULVVn nP111VL1[ VLIPIIL ALL PIPE TO BE 1"CPVC UNLESS OTHERWISE NOTED PIPE A%N� INSULATION TENTING DETAIL 0 0 1.25" 3RD FLOOR 1.25" TO 3RD FLOOR SCALE 1/8._ 10-00 TO 3RD FLOOR FROM 1 st FLOOR FROM 1 st FLOOR Sheet Title Stamp EXPt7C5 WASHINGTON STATE OEC 31.25 CERTIFICATE OF COMPETENCY FIRE SPRINKLER SYSTEMS 1 Michael 0. Hutchinson 1 1166-0599-BG Level i Evergreen Fire Protection, Inc. EVERGFP 67LZ Signature Date m ixmeimawmaremYmmaucmsmmemmw ��.� QUAN TEMP KFACTOR EVERGREEN SIRE PROTECTION INCY NFPA 13R FIRE PLAN 245 155* 49 POyalOp,9WA 98371 Tchomc Terra 2 Apts. Ed C EVERGFP967LZ .1 / Zq 15 ' 1 5.6 Phone: (253) 252-7942 Job Title 14301 TA HOMA BL VD r//Al rEl SE Reliable DH 56 DRY Sidewall 28'x10' 6 155° 5.6 YELM, WA 98597 TOTAL 249 DATE: 2/27/2025 REV: DRAWN: MH SHEET: 2 0F 2 :]� I