Loading...
AQUATIC BATH MAIN BLDG AES“” OWNER / TENANT FIRE ALARM CONTRACTOR 1 Manual Fire Alarm Pull-Station 2 Smoke Detectors 3 4 5 6 7 8 9 Fire Alarm AC Power Failure Fire Alarm System Low Battery Open Circuit Ground Fault A B C D E F G H I Control Unit Annunciation Required Fire Safety Control SYSTEM OUTPUTS 10 AL R M SU P TR B L Sprinkler Tamper Unused Central Supervising Station 1 2 3 4 5 6 7 8 9 A Ac t u a t e A u d i b l e A l a r m S i g n a l B Ac t u a t e A u d i b l e S u p e r v i s o r y S i g n a l C Ac t u a t e A u d i b l e C o m m o n T r o u b l e S i g n a l D E F Tr a n s m i t F i r e A l a r m S i g n a l t o S u p e r v i s i n g S t a t i o n G Tr a n s m i t S u p e r v i s o r y S i g n a l t o t h e S u p e r v i s i n g S t a t i o n H Tr a n s m i t T r o u b l e S i g n a l t o t h e S u p e r v i s i n g S t a t i o n I Tr a n s m i t W a t e r f l o w A l a r m t o t h e S u p e r v i s i n g S t a t i o n SYSTEM INPUTS Ac t i v a t e B u i l d i n g ' s O c c u p a n t N o t i f i c a t i o n D e v i c e s Ac t i v a t e E x t e r i o r S t r o b e f o r A p p r o a c h i n g E m e r g e n c y V e h i c l e s 10 N Not to Scale FACP on SUPPLY RM MEZZANINE EXISTING FIRELITE MS-5024UD FIRE ALARM CONTROL PANEL TYPICAL WIRING AND INSTALLATION DETAILS RELAY 1RELAY 2 NO COM NC NO COM NC ALARMTROUBLE WIRING TO BE INSTALLED IN A METAL RACEWAY RELAY 3RELAY 4 NO COM NC NO COM NC SUP STATUS INDICATORSRESET J1 T R T R T R T R ZONES 1-8 INPUT TRIGGERS 1 C C C C234567 8 J2 J6 J5 AES-7707-88-ULP RADIO COMMUNICATOR BAT +- TR A N S C E I V E R ANTENNA CUT RELAY TELCO IN TELCO IN X-FORMER IN NEMA BOX WIRING TO BE INSTALLED IN A METAL RACEWAY RECEPTACLE FOR THE AES X-FORMER MUST BE ON A DEDICATED 120VAC CIRCUIT OUTDOOR BELL Dry Waterflow Wet Waterflow NW R H O T O N R D NOR T H E R N P A C I F I C R D S E OUTDOOR BELL DR A W N B Y : N I C K C H A N D L E R , A E T N I C E T I I I - # 1 4 8 1 2 1 RE V I E W E D B Y D A V I D M O W , S E T N I C E T I V - # 1 2 0 9 0 4 SE A T T L E F I R E D E P T . # S C P - C 9 9 5 5 L & I # C A T S * R L 0 2 2 C G PR O P E R T Y O F / A L L R I G H T S R E S E R V E D F . P . I . DA V I D M O W : DATE / DESCRIPTION SHEET NUMBER SHEET TITLE PROJECT NAME DATE:03/04/2025 REVISION RECORD AQ U A T I C B A T H MA I N B U I L D I N G 80 1 N O R T H E R N P A C I F I C R D S E YE L M , W A 9 8 5 9 7 FIRE PROTECTION INC. 17410 Ash Way, Ste 8 Lynnwood, WA 98037 425-290-9600 FPISEATTLE.COM FIRE ALARM PROJECT DETAILS FA 0.0 SHEET INDEX PROJECT DETAILS PROJECT CONTACT INFO CODE INFO REPORTING ZONE FROM RADIO SEQUENCE OF OPERATIONSSITE PLAN INSTALLATION NOTES DEVICE INSTALLATION REQUIREMENTS TYPICAL INSTALLATION DETAIL VICINITY MAP