Loading...
jenna fisher-naputi Permit Pack stampedRESIDENTIAL ROOFTOP SOLAR PERMIT PACKAGE d06 PV Installation Professional Cecil Lopeman #042013-75 SCOPE OF WORK INSTALLATION OF ROOFTOP MOUNTED PHOTOVOLTAIC SOLAR SYSTEM TYPICAL STRUCTURAL INFORMATION ROOF MATERIAL: Comp Shingle SHEATHING: OSB FRAMING: Manufactured Truss RACKING: UNIRAC SFM INFINITY ROOF ATTACHMENT: UNIRAC SFM BUTYL TOTAL ATTACHMENTS: 26 GENERAL NOTES jenna fisher-naputi Enphase 14918 89th ave se Platinum yelm, Washington 98597 qp Installer 3605610794 NEW PV SYSTEM INFORMATION DC SYSTEM SIZE: 4.3 kW DC AC SYSTEM SIZE: 3.25 kW AC MODULE TYPE: (10) Silfab Solar SIL-430 QD X- C4 INVERTER TYPE: (10) Enphase IQ8M-72-M-US ° WAS Y 3/G/2025 AHJ City of Yelm WA by lohn-A Calvi UTILITY COMPANY Date- 202 S 03 0( �.—.��...-ram �� Puget Sound Energy 10:15:18-07'00' SHEET INDEX PV1 COVER SHEET PV2 SITE PLAN PV3 ROOF PLAN PV4 STRUCTURAL PV5 ELECTRICAL 3-LINE PV6 ELECTRICAL CALCULATIONS PV7 LABELS PV8 PLACARD SS SPEC SHEETS CEC-AC SYSTEM SIZE: 3.388 kW AC TOTAL PV DC SYSTEM SIZE TOTAL PV AC SYSTEM SIZE 4.300 kW DC 3.250 kW AC DESIGN CRITERIA WIND SPEED: 1 10 WIND EXPOSURE FACTOR: C RISK CATEGORY: II GROUND SNOW LOAD: 25 ROOF SNOW LOAD: 25 SEISMIC DESIGN CATEGORY: D WEATHER STATION DATA WEATHER STATION: TACOMA NARROWS HIGH TEMP 2% AVG: 28°C EXTREME MINIMUM TEMP: -40C APPLICABLE CODES *2023 NATIONAL ELECTRIC CODE (NEC) *2021 INTERNATIONAL BUILDING CODE (IBC) *2021 INTERNATIONAL RESIDENTIAL CODE (IRC), 2021 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com co Q i > O Lu -C y000 � N O O CO O v) IL W � z Z a a z W O U O = U a PROJECTID: 1286739 PV DC SYSTEM SIZE: 4.300 kW DC PV AC SYSTEM SIZE: 3.250 kW AC A Jordan Davis PLOT DATE: March 6, 2025 Cover Sheet G NUMBER: PV1 VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com — F \ M C CB C O, LJ u C300 ® 0 Sealed For i > o >Q E LL ' = Existing Roof & Q� ® O Attachment Only H � N o ® I 00 a o o 3 }❑ ® ❑ I Z U 11 I I� ® C4 l � a Z } Z a a O j / 46056 Vl J fS�Tt / �ffyr,�j u 12. PROJECT ID: 1286739 IL— 3/G/2025 PV DC SYSTEM SIZE: — 4.300 kW DC PV AC SYSTEM SIZE: 3.250 kW AC REVISIONS: 14918 89th ave se 0 0 0 SITE PLAN SCALE: 1/ 16" = 1'-0" D 0 LEGEND PV SYSTEM SPECIFICATIONS COMPASS DRAWN BY: Jordan Davis r—M]UTILITY METER FBE]ENCLOSURE BREAKER BAT ESS - BATTERY FIRE SETBACK F]HATCH TRENCH OR OVERHEAD NEW PV SYSTEM INFORMATION N PLOT DATE: March 6, 2025 PV MODULE: (10) Silfab Solar SIL-430 QD, POWER RATING: 430 W DRAWING TITLE: SP MAIN SERVICE AC AC DISCONNECT [ESC] ESS - CONTROLLER °q MICROINVERTER i PROPERTY LINE F INVERTER: (10) Enphase IQ8M-72-M-US, POWER RATING: 325 W PANEL I E Site Plan SUB SUBPANEL PV PV PRODUCTION METER REMOTE POWER RPO OFF SWITCH ROOFTOP , JUNCTION BOX W DRAWING NUMBER: CTLCABINETUTIITY METERCB COMBINER BOX ATSATS PANELGENERATORINV INVERTER ICONS WITH DOTTED OUTLINE INDICATE INTERIOR LOCATION \ /^CT PVL/ S VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 UNDERGROUND SERVICE LINE BlueRavenSolar.com POINT OF INTERCONNECTION �AC IMSP 3I 0 3, 1' 6„ 3' ♦� I� MP1 I-6„ • ��" NO• Q MODULE QTY: 10 ® N 3 AZIMUTH:274 3 `w` i> O E w PITCH: 23 TSRF:83 < Sealed For o� N > AREA: 500 ft2 ® = Existing Roof & H 0D "' p o lL Attachment Only `� O _ SKYLIGHT--E] z •� OLL- OV WAS � Z a a W O O U U Q J � PR OJECT ID: 46036 '°� NAt 1286739 PV DC SYSTEM SIZE: 4.300 kW DC PV AC SYSTEM SIZE: 3/E/2025 3.250 kW AC REVISIONS: A 0 ROOF PLAN SCALE: 1/8"= 1'-0" D Q LEGEND PV SYSTEM SPECIFICATIONS COMPASS DRAWN BY: Jordan Davis r—M]UTILITY METER FBE]ENCLOSURE BREAKER BAT ESS - BATTERY F]HATCH FIRE SETBACK TRENCH OR OVERHEAD NEW PV SYSTEM INFORMATION N PLOT DATE: March 6, 2025 PV MODULE: (10) Silfab Solar SIL-430 QD, POWER RATING: 430 W DRAWING TITLE: SP MAIN SERVICE AC AC DISCONNECT [ESC] ESS - CONTROLLER °q MICROINVERTER i PROPERTY LINE F INVERTER: (10) Enphase IQ8M-72-M-US, POWER RATING: 325 W PANEL E Roof Plan SUB SUBPANEL rpV] PV PRODUCTION REMOTE POWER [R—po] , ROOFTOP W DRAWING NUMBER: METER OFF SWITCH JUNCTION BOX CT CTLUTIITY METECABINETR H COMBINER BOX HATS PANELGENERATOR H INVERTER ICONS WITH DOTTED OUTLINE INDICATE INTERIOR LOCATION PV3 S PANEL AZIMUTH PITCH TSRF AREA FRAMING SIZE CEILING JOIST/ MAXIMUM MAXIMUM PRIMARY PV ARRAY AREA (W) 209.99 COUNT (DEG) (DEG) (%) (ft') ROOF MATERIAL SHEATHING TYPE FRAMING TYPE AND SPACING PURLINS SIZE RACKING TYPE ATTACHMENT TYPE ATTACHMENT CANTILEVER PRIMARY ROOF AREA (ft') 1673.07 AND SPACING SPACING (S) (C) PRIMARY ROOF COVERAGE (%) 12.55 MPI 10 274 23 83 500 Comp Shingle OSB Manufactured Truss 2x4 @ 24 in OC 2x4 @ 24 in OC UNIRAC SFM INFINITY UNIRAC SFM BUTYL 72" L / 48" P 24" L / 16"P SECONDARY PV ARRAY AREA [W) IF APPLICABLE SECONDARY ROOF AREA (ff') SECONDARY ROOF COVERAGE BLUE RAVEN MP2 0 MP3 0 (%) MP4 1 0 TOTAL PV ARRAY WEIGHT (Ibs) TOTAL PV ATTACHMENTS POINT LOAD 463 26 SOLAR MPS 0 1403 N 630 E MP6 0 (Ibs/aff.) DISTRIBUTED LOAD (psf) 17.8 2.2 Orem, Utah 84097 MP7 0 MP8 0 (800) 377-4480 BlueRavenSolar.com MP9 0 MPIO 0 ATTACHMENT TYPE: PV MODULES SHALL NOT EXTEND Unirac SFM Butyl ABOVE ROOF RIDGE LINE PV MODULE MAX CANTILEVER PER TABLE ABOVE PV MODULES SHALL NOT EXTEND MORE THAN (C) 6 INCHES FROM THE PLANE OF THE ROOF f� UNIRAC UNIRAC PV MODULE SFM INFINITY SFM INFINITY Q Ln i` 2" MICRORAIL 6.5"SPLICE v) � >� � O W ROOF MATERIAL NOT EXISTING FRAMING /L SHOWN FOR CLARITY N y oo N O 1 Y' MIN. (2) #14-14x3"SCREW W/ EPDM WASHER T T EMBEDMENT 3 } U W ATTACHMENT SPACING i- PER TABLE ABOVE Vi FRAMING SPACING *THIS DETAIL IS NOT MEANT TO BE PER TABLE ABOVE FRAMING DETAIL EXTERIOR WALL AN EXACT REPRESENTATION OF ATTACHMENT DETAIL SCALE: 1 /2" = 1'-0" FRAMING OR PV MODULE LAYOUT SCALE: 1-1 /2" = 1'-0" Z a RIDGE i NOTES i I LANDSCAPE PORTRAIT Sealed For u a m I II0 0 0 Existing Roof & PROJECTID: Attachment Only 1286739 PV DC SYSTEM SIZE: 4.300 kW DC PV AC SYSTEM SIZE: 3.250 kW AC REVISIONS: ►• C OF WAS t{* 0 sA DRAWN BY: i1 Jordan Davis 46 56 PLOT DATE: .tfs March 6, 2025 `'IptC* DRAWING TITLE: Structural FOLLOW ATTACHMENT SPACING IN TABLE ABOVE SAVE 3/6/2025 DRAWING NUMBER: *ATTACHMENT PATTERN SHOULD BE ATTACHMENT PATTERN STAGGERED UNLESS OTHERWISE PV4 SCALE: 1/4" = 1'-0" NOTED IN ENGINEERING LETTER v Ll (1) 10 AWG THHN/THWN-2 CU BLACK 4 L2 (1) 10 AWG THHN/THWN-2 CU RED N (1) 10 AWG THHN/THWN-2 CU WHITE G (1) 10 AWG THHN/THWN-2 CU GREEN 3/4 INCH EMT Exterior Ll (1) IOAWGTHHN/THWN-2CUBLACK 3/4INCH 3 L2 (1) 10 AWG THHN/THWN-2 CU RED EMT* G (1) IO AWG THHN/THWN-2CU GREEN *TYPE OF CABLE MAY BE SUBSTITUTED FOR USE IN CONDUIT WHERE ELECTRICAL CODE PERMITS 2 Ll (1) 10 AWG THHN/THWN-2 CU BLACK 3/4INCH L2 (1) 10 AWG THHN/THWN-2 CU RED G (1) 10 AWG THHN/THWN-2CU GREEN *TYPE NM (ROMEX) OR OF CABLE IS PERMITTED FOR INTERIOR OR ATTIC RUNS AND SHALL BE USED WHEN ELECTRICAL CODE PERMIT 1 Ll (1) 12 AWG THHN/THWN-2 CU BLACK L2 (1) 12 AWG THHN/THWN-2 CU RED G (1) 6 AWG BARE, CU ENPHASE Q-CABLE, 2-WIRE, FREE AIR Exterior GROUNDING ELECTRODE SYSTEM SHALL BE IN ACCORDANCE WITH NEC 250.53. PRIMARY PV COMBINER BOX OTHER NOTES ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN IO' OF UTILITY METER. -0 :S 'ERS I BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com 00 Q 2 i > O LLJ y000 N O O CO O v) IL z Z a a z W O U O F � 2 U a PROJECTID: 1286739 PV DC SYSTEM SIZE: 4.300 kW DC PV AC SYSTEM SIZE: 3.250 kW AC A Jordan Davis PLOT DATE: March 6, 2025 Electrical 3-Line G NUMBER: PV5 BLUE RAVEN 1403 N 630 E AC SYSTEM SIZE 3.25kW AC BUSBAR RATING 200A ----A ----A WEATHER STATION TACOMA NARROWS WIRE SIZE SPECIFICATIONS MINIMUM CONDUCTOR AMPACITY 16.88A AC 16.88A AC 16.88A AC 16.88A AC --A AC --A AC A AC --A AC --A AC A AC CONDUCTOR MATERIAL CU CU CU CU ---- ---- ---- ---- ---- ---- CONDUCTOR TYPE THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 -- -- -- -- -- -- CONDUCTOR SIZE 12 AWG 10 AWG 10 AWG 10 AWG ---- CONDUCTOR AMPACITY 30A 40A 40A 40A --A --A --A --A --A --A AMBIENT TEMPERATURE ADJUSTMENT FACTOR 1 1 1 1 ---- ---- ---- ---- ---- ---- CONDUIT FILL ADJUSTMENT FACTOR 1 1 1 1 -- -- -- -- -- ADJUSTED CONDUCTOR AMPACITY 30A 40A 40A 40A ----A ----A ----A ----A ----A ----A WIRE RUN DISTANCE (FT) bb 50 20 5 -- -- -- -- -- CALCULATED VOLTAGE DROP 0.8% 0.7% 0.28% 0.07% 0% 0% 0% 0% 0% 0% PV CIRCUIT SPECIFICATIONS PRIMARY STRUCTURE DETACHED STRUCTURE CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUITS CIRCUIT 6 CIRCUIT 7 CIRCUIT 8 CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUITS NUMBER OF MODULES PER CIRCUIT 10 0 0 0 0 0 0 0 0 0 0 0 0 RATED AC OUTPUT CURRENT (lay,) 13.5A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA MINIMUM AMPACITY (lour x 125%) 16.9A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA OVERCURRENT PROTECTION RATING 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A COMBINED AC OUTPUT CURRENT (Cap.) 13.5A O.OA VOLTAGE DROP WIRE TAG #1 0.8% WIRE TAG #4 0.07% WIRE TAG #5 0% PV CIRCUIT SPECIFICATIONS PRIMARY STRUCTURE DETACHED STRUCTURE CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUITS CIRCUIT 6 CIRCUIT 7 CIRCUIT 8 CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUITS NUMBER OF MODULES PER CIRCUIT 10 0 0 0 0 0 0 0 0 0 0 0 0 RATED AC OUTPUT CURRENT (lay,) 13.5A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA MINIMUM AMPACITY (lour x 125%) 16.9A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA OVERCURRENT PROTECTION RATING 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A COMBINED AC OUTPUT CURRENT (Cap.) 13.5A O.OA VOLTAGE DROP WIRE TAG #1 0.8% WIRE TAG #4 0.07% WIRE TAG #5 0% VOLTAGE DROP WIRE TAG #1 0.8% WIRE TAG #4 0.07% WIRE TAG #5 0% WARNING LABELS UTILITY METER AWARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM IN CASE OF EMERGENCY, PLEASE CONTACT: BLUE RAVEN SOLAR (800) 377-4480 MAIN SERVICE PANEL SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE .OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD N THE ARRAY. A CAUTION MULTIPLE SOURCES OF POWER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY. PV DISCONNECT IS LOCATED WITHIN 10 FT AND LINE OF SIGHT OF UTILITY METER. WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE *LABEL INSTALLED NEXT TO PV BREAKER PV AC DISCONNECT PHOTOVOLTAIC DISCONNECTA AC RATED AC OUTPUT CURRENT 13.5 A NOMINAL OPERATING AC VOLTAGE 240 V OWARNING ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PV COMBINER BOX PHOTOVOLTAIC SYSTEM COMBINER PANEL WWAMM AUTHORIZED PERSONNEL ONLY DO NOT ADD LOADS NO DC WIRES PRESENT RAPID SHUTDOWN TEST NOT REQUIRED BLUE RAVEN SOLAR 1403 N'30 E Orem, Utah 84097 (800)377-4480 BlueRavenSolar.com D` V /000 ^�` O`- W 2Q i C C / E Lu H000 N O O Co O v> W � � a z a a Z a W O U O t~Il F � U 2 a PROJECTID: 1286739 PV DC SYSTEM SIZE: 4.300 kW DC PV AC SYSTEM SIZE: 3.250 kW AC A ZL 0 Jordan Davis PLOT DATE: March b, 2025 Warning Labels DRAWING NUMBER: PV7 SIL-420/430 QD •� INTRODUCING NEXT -GENERATION • N-TYPE CELL TECHNOLOGY • Improved Shade Tolerance • Enhanced Durability • Improved Low -Light Performance • Reduced Degradation Rate • Increased Performance in • Industry -Leading Warranty High Temperatures 1 � 1 SILFABSOLAR.COM I F(+ • • • 00000 SILFAB • SOLAR® a � ■ ■ ELECTRICAL SPECIFICATIONS 420 0 Test Conditions STC NOCT ' Module Power(Pmax) Wp 420 313 Maximum powervoltage (Vpmax) V 33.08 30.86 Maximum powercurrent(Ipmax) A 12.70 10.15 -- opencircuitvoltage(Voc) V 38.84 36.52 Short circuitcurrent(Isc) A 13.50 10.85 Module efficiency % 21.5% 20.1% Maximum system voltage (VDC) V 1000 Series fuse rating A 25 Power Tolerance Wp 0 to +10 Measurement conditions: STC 1000 W/m' • AM 1.5 • Temperature 25 °C • NOCT 800 W/m' • AM 1.5 • Measurement uncertainty <_ 3% Sun simulator calibration reference modules from Fraunhofer Institute. Electrical characteristics may vary by±5%and power by 0 to+10 W. MECHANICAL PROPERTIES / COMPONENTS METRIC IMPERIAL ' Moduleweight 21 kg±0.2 kg 46.3lbs ±0.4lbs Dimensions(H x L x D) 1721 mm x 1133 mm x 35 mm 67.8 in x 44.6 in x 1.37 in Maximum surface load (wind/snow)* 4000 Pa rear load / 5400 Pa front load 83.5 lb/ft2 rear load / 112.81b/ft2 front load Hail impact resistance a 25 mm at 83 km/h o 1 in at 51.6 mph Cells 108 Half cells - N-Type Silicon solar cell 108 Half cells - N-Type Silicon solar cell 182mmx91mm 7.16 in x 3.58 in Glass 3.2 mm high transmittance, tempered, 0.126 in high transmittance, tempered, antireflective coating antireflective coating Cables and connectors (refer to installation manual) 1350 mm, a 5.7 mm, MC4 from Staubli 53.1 in, a 0.22 in (12 AWG), MC4 from Staubli Backsheet High durability, superior hydrolysis and UV resistance, multi -layer dielectric film, fluorine -free PV backsheet Frame Anodized aluminum (Black) Junction Box UL 3730 Certified, IEC 62790 Certified, IP68 rated, 3 diodes TEMPERATURE RATINGS WARRANTIES Temperature Coefficient lsc 0.04%/°C Module product workmanship warranty 25 years** Temperature Coefficient Voc -0.24%/°C Linear power performance guarantee 30years Temperature Coefficient Pmax -0.29%/°C >_98%end lst yr NOCT (±2 °C) 45 °C > 94.7%end 12th yr >_ 90.8%end 25th yr Operating temperatu re -40/+85°C >_89.3%end 30thyr CERTIFICATIONS SHIPPING SPECS UL 6121�IEC6271il CSA C22.2#61730, IEC 61215, IEC 61730, IEC 61701(Salt Mist Product Corrosio(Ammonia Corrosion), CEC Listed, UL Fire Rating: Type 2 Factory IS09001:2015 * A Warning. Read the Safety and Installation Manual for mounting specifications and before handling, installing and operating modules. ** 12 year extendable to 25 years subject to registration and conditions outlined under "Warranty" at silfabsolar.com. PAN files generated from 3rd party performance data are available for download at: silfabsolar.com/downloads. r ell .9 4 0 A 0 67.8" [1721 mm] T v E � M 11.8" [300.5mm] 44.1" [1120mm] 11.8" [300.5mm] O+ ounting Hole (x4) 0.5" [12mm] 1.4" [35mm] a 1� o o tE E on on ray 11�1 tE 0 co 3 0.06" v [1.5mm] o E_ N C 53.15" m Cable Length c C7 rainage Hole (x8) 8" [200mm] I Modules Per Pallet: 26 or 26 (California) Pallets Per Truck 32 or30 (California) Modules Per Truck 832 or 780 (California) SILFAB SOLAR INC. 1770 Port Drive Burlington WA98233 USA T+1360.569.4733 info@sitfabsolar.com S I L FA B S O L A R. C OM 7149 Logistics Lane Fort Mill SC 29715 USA T +1839.400.4338 240 Courtneypark Drive East Mississauga ON L5T 2Y3 Canada T +1905.255.2501 F +1905.696.0267 Silfab - SIL-420/430-QD-20240227 No reproduction of any kind is allowed without permission. Data and information is subject to modifications without notice.© Silfab Solar Inc., 2022. Silfab Solar° is a registered trademark of Silfab Solar Inc. BLUE RAVEN SOLAR DRAWING NUMBER: SS Nome UNI RAC BLUE RAVEN April 11", 2024 SOLAR To Whom It May Concern, This letter is confirmation that the Silfab SIL-xxx QD module is compatible with Unirac's SFM racking system. The Silfab SIL-xxx QD module has been reviewed to ensure that, when installed with SFM, all structural and grounding and bonding features of the racking system mate properly with the module's frame. Silfab SIL-xxx QD is UL fire rated as a Type 2 module, for which the SFM system is UL 2703 certified. The Unirac product warranty applies to the installation of the Silfab SIL-xxx QD module with SFM. Please contact Unirac with any questions. Regards, Robert D'Anastasio Validation Engineer robert.danastasio@unirac.com Unirac, Inc. • www.unirac.com DRAWING NUMBER: 1411 Broadway Blvd. NE • Albuquerque, NM • 87102-1545 • Ph: (505) 242-6411 • Fax: (505) 242-6412 SS EN PHASE m IQ8M and IQ8A Microinverters BLUE RAVEN SOLAR IQ8M and IQ8A Microinverters Our newest IQ8 Microinverters are the industry's first microgrid-forming, software - defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application -specific integrated circuit (ASIC), which enables the microinverter to operate in grid -tied or off -grid modes. This chip is built using advanced 55-nm technology with high-speed digital logic and has superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. ItIrt Connect PV modules quickly and easily to the IQ8 Series Microinverters that have integrated MC4 connectors. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with various regulations when installed according to the manufacturer's instructions. * Meets UL 1741 only when installed with IQ System Controller 2. ** IQ8M and IQ8A support split -phase, 240 V installations only. Commonly used module pairings' W 260-460 295-500 Module compatibility To meet compatibility, PV modules must be within the following maximum input DC voltage and maximum module Ix Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator MPPT voltage range v 30-45 32-45 Operating range V 16-58 Minimum/Maximum start voltage V 22/58 Maximum input DC voltage V 60 Maximum continuous input DC current A 12 Maximum input DC short-circuit current A 25 Maximum module I A 20 Overvoltage class DC port II DC port backfeed current mA 0 PV array configuration OUTPUT DATA 1 x 1 ungrounded array; no additional DC side protection required; AC side protection requires max 20 A per branch circuit Peak output power VA Q: 3 SU 366 Maximum continuous output power VA '25 349 Nominal grid voltage (L-L) v 240, split -phase (L-L),180' Minimum and Maximum grid voltage2 v 211-264 Maximum continuous output current A 1. S�l 1.45 Easy to install Lightweight and compact with plug- Nominal frequency Hz 60 and -play connectors Extended frequency range Hz 47-68 Power line communication (PLC) between components ACshort-circuitfault current over Arms 2 three cycles • Faster installation with simple two - wire cabling Maximum units per 20 A (L-L) branch clrcult3 11 High productivity and reliability Total harmonic distortion / <5 Produce power even when the grid is down* Overvoltage class AC port III More than one million cumulative AC port backfeed current mA 30 hours of testing Class II double -insulated enclosure Power factor setting 1.0 Optimized for the latest high- Grid -tied power factor (adjustable) 0.85leading ... 0.85 lagging powered PV modules Peak efficiency / 11111i19, 97.7 Microgrid-forming CEC weighted efficiency % 97.5 97 Complies with the latest advanced Nighttime power consumption mW 21 22 grid support** MECHANICAL DATA Remote automatic updates for the latest grid requirements Ambient temperature range -40°C to 60°C (-40°F to 140T) Configurable to support a wide Relative humidity range 4% to 100% (condensing) range of grid profiles • Musts CA RuFa 2; (UL 1741-5A) and IEEE DC connector type Staubli MC4 1547,2018 (UL 1741-SB Sn Ed.) Dimensions (H • W • D) 212 mm (8.3") • 175 mm (6.9") • 30.2 mm 0.2") NOTE: Weight 1.1 kg (2.43lbs) • IQ8 Microinverters cannot be mixed together with Cooling Natural convection -no fans previous generations of Enphase microinverters 007 Series, IQ6 Series, and so on) in the same Approved for wet locations Yes system. Pollution degree PD3 • IQ Gateway is required to change the default grid profile at the time of installation to meet the local Enclosure Class II double -insulated, corrosion -resistant polymeric enclosure Authority Having Jurisdiction (AHJ) requirements. Environmental category/UV exposure rating NEMA Type 6/outdoor (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. DRAWING NUMBER: I08MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. IQ8MA-MC4-DSH-00205-2.0-EN-US-2023-11-03 SS Data Sheet Enphase Q Cable Accessories REGION: Americas Enphase Q Cable Accessories To learn more about Enphase offerings, visit enphase.com The Enphase Q Cable'"' and accessories are part of the latest generation Enphase IQ System'"'. These accessories provide simplicity, reliability, and faster installation times. Enphase Q Cable • Two -wire, double -insulated Enphase Q Cable is 50% lighter than the previous generation Enphase cable • New cable numbering and plug and play connectors speed up installation and simplify wire management • Link connectors eliminate cable waste Field-Wireable Connectors • Easily connect Q cables on the roof without complex wiring • Make connections from any open connector and center feed any section of cable within branch limits Available in male and female connector types Enphase Q Cable Accessories CONDUCTOR SPECIFICATIONS Certification UL3003 (raw cable), UL 9703 (cable assemblies), DG cable Flame test rating FT4 Compliance RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Q CABLE TYPES / ORDERING OPTIONS Connectorized Models Size / Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG / 277 VAC 1.3 m (4.2 ft) Portrait 240 Q-12-17-240 12 AWG / 277 VAC 2.0 m (6.5 ft) Landscape (60-cell) 240 Q-12-20-200 12 AWG / 277 VAC 2.3 m (7.5 ft) Landscape (72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Field-wireable connector (male) Q-CONN-10M Make connections from any open connector Field-wireable connector (female) Q-CONN-10F Make connections from any Q Cable open connector Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount Q Cable sealing caps (female) Q-SEAL-10 One needed to cover each unused connector on the cabling Terminator Q-TERM-10 Terminator cap for unused cable ends Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4 (TE PV4-S SOLARLOK). 150mm/5.9" to MC4. Enphase EN4 non -terminated adaptor' ECA-EN4-FW For field wiring of UL certified DC connectors. EN4 (TE PV4-S SOLARLOK) to non -terminated cable. 150mm/5.9" Enphase EN4 to MC4 adaptor (long)' ECA-EN4-S22-L Longer adapter cable for EN4 (TE PV4-S SOLARLOK) to MC4. Use with split cell modules or PV modules with short DC cable. 600mm/23.6" Replacement DC Adaptor (MC4) Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) Replacement DC Adaptor (UTX) Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) 1. Qualified per UL subject 9703 TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends, sold in packs of ten and cable connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL Plan to use at least one per CABLE CLIP Used to fasten cabling to the racking installation, sold in packs of ten or to secure looped cabling, sold in (Q-DISC-10) packs of one hundred (Q-CLIP-100) To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ EN P H A S E. Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. �1 E N P H A S E 2020-06-26 BLUE RAVEN SOLAR DRAWING NUMBER: SS n ENPHASE IQ Combiner 5/5C The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, pre -wired solution for residential applications. IQ Combiner 5/5C uses wired control communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. The IQ Combiner 5/5C, IQ Series Microinverters, IQ System Controller 3/3G, and IQ Battery 5P provide a complete grid -agnostic Enphase Energy System. IQ Series Microinverters The high-powered smart grid -ready IQ Series Microinverters (I06, IQ7, and IQ8 Series) simplify the installation process. 11 10 Battery 5P Fully integrated AC battery system. Includes six field -replaceable IQ8D-BAT Microinverters. C@" LISTED 5-year limited warranty IQ System Controller 3/3G Provides microgrid interconnection device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid "-wPr tc backup power. IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life. NON *For country -specific warranty information, see the https://enphase.com/installers/resources/warranty page. ® 2024 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. IQ Combiner 5/5C I BLUE RAVEN SOLAR IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue -grade PV production IQ Combiner 5 (X-IQ-AM1-240-5) metering (ANSIC12.20 ±0.5%), consumption monitoring (± 2.5%), and IQ Battery monitoring U2.5%). Includes a silver solar shield to deflect heat. IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue -grade PV production IQ Combiner 5C (X-I0-AM1-240-5C) metering (ANSI C12.20±0.5%), consumption monitoring U2.5%) and IQ Battery monitoring U2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05)'. Includes a silver solar shield to deflect heat. IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive, remote maintenance, and management of the Enphase Energy System Busbar 80 A busbar with support for 1 • IQ Gateway breaker and 4.20 A breaker for installing IQ Series Microinverters and IQ Battery 5P IQ Gateway breaker Circuit breaker, 2-pole, 10 A/15 A Production CT Pre -wired revenue -grade solid -core CT, accurate up to ±0.5% X-IQ-AM1-240-5 Consumption CT Two consumption metering clamp CTs, shipped with the box, accurate up to±2.5% X-IQ-AM1-240-5C IQ Battery CT One battery metering clamp CT, shipped with the box, accurate up to±2.5% CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P Enphase Mobile Connect (only with IQ Combiner 5C) 4G-based LTE-M1 cellular modem (CELLMODEM-MI-06-SP-05) with a 5-year T-Mobile data plan Accessories kit Spare control headers for the COMMS-KIT-02 board Smart Includes IQ Gateway for REPLACEMENT PARTS ACCESSORIES r r INCLUDED, ORDER communication and control CELLMODEM-MI-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan Includes Enphase Mobile Connect CELLMODEM-MI-06-AT-05 4G-based LTE-MI cellular modem with a 5-year AT&T data plan (CELLMODEM-M1-06-SP-05), only with IQ Combiner 5C Supports Eaton BR2XX, Siemens Q2XX and GE/ABB THQL21XX Series circuit breakers (XX represents Circuit breakers (off -the -shelf) 10,15, 20, 30, 40, 50, or 60). Also supports Eaton BR220B, BR230B, and BR240B circuit breakers Supports flexible networking: Wi-Fi, compatible with the hold-down kit. Ethernet, or cellular Provides production metering Circuit breakers (provided b Enphase) P y P BRK-10A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-B, and BRK-20A-2P- "Accessories" (revenue grade) and consumption 24OV-S (more details in the section) monitoring XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board (PCB) for IQ Combiner 5/5C Easy to install X-IQ-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers (with screws) Mounts to one stud with centered brackets XA-COMMS2-PCBA-5 Replacement COMMS-KIT-02 printed circuit board (PCB) for IQ Combiner 5/5C Supports bottom, back, and side ELECTRICAL SPECIFICATIONS conduit entries Rating 80 A Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers System voltage and frequency 120/240 VAC, 60 Hz (not included) Busbar rating 125 A 80 A total PV branch circuits Fault current rating 10 kAIC Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup Maximum continuous current rating (input from PV/storage) 64 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR, Siemens Q, or GE/ABB THQL Series distributed generation (DG) breakers Reliable only (not included) Durable NRTL-certified NEMA type 3R Maximum total branch circuit breaker rating (input) 80 A of distributed generation/95 A with IQ Gateway breaker included enclosure IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included 5-year limited warranty Production metering CT 200 A solid core pre -installed and wired to IQ Gateway 2-year labor reimbursement program coverage included for both the Consumption monitoring CT (CT-200-CLAMP) A pair of 200 A clamp -style current transformers is included with the box IQ Combiner SKUs IQ Batter metering CT y gy 200 A clamp -style current transformer for IQ Batter metering, g, included with the box UL1741 Listed 1. A plug -and -play industrial -grade cell modem for systems of up to 60 microinverters. Available in the United States, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area. DRAWING NUMBER: IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 SS Dimensions (W • H x D) 37.5 cm • 49.5 cm • 16.8 cm (14.75" • 19.5.6.63"). Height is 21.06" (53.5 cm) with mounting brackets Weight 7.5 kg (16.5 Ibs) Ambient temperature range -400C to 460C (-40°F to 115°F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Wire sizes Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing Communication (in -premise connectivity) Built-in CTRL board for wired communication with IQ Battery 5P and IQ System Controller 3/3G. Integrated power line communication for IQ Series Microinverters Altitude Up to 2,600 meters (8,530 feet) Integrated Wi-Fi 802.11b/g/n (dual band 2.4 GHz/5 GHz), for connecting the Enphase Cloud through the internet Wi-Fi range (recommended) 10 m (32.8 feet) Bluetooth BLE4.2,10 m range to configure Wi-Fi SSID Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included), for connecting to the Enphase Cloud through the internet Cellular/Mobile Connect CELLMODEM-MI-06-SP-05 or CELLMODEM-M1-06-AT-05 (included with IQ Combiner 5C) Digital I/O Digital input/output for grid operator control USE; 2.0 Mobile Connect, COMMS-KIT-01 for IQ Battery 3/3T/10/10T, COMMS-KIT-02 for IQ Battery SP Access point (AP) mode For connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs, one IQ Battery CT, and one Production CT Power line communication 90-110 kHz Web API See https://developer-v4.enphase.com Local API See guide for local API IQ Combiner with IQ Gateway PV Microinverters IQ System Controller COMMS-KIT-012 IQ System Controller 2 IQ Battery IQ System Controller 3 COMMS-KIT-02' IQ Battery UL 1741, CAN/CSA C22.2 No.107.1, Title 47 CFR, Part 15, Class B, ICES 003, NOM-208-SCFI-2016, UL 60601-1/CANCSA 22.2 No.61010-1, IEEE 1547:2018 (UL 1741-SB, 3rd Ed.), IEEE 2030.5/CSIP Compliant, Production metering: ANSI C12.20 accuracy class 0.5 (PV production) IQ6, IQ7, and IQ8 Series Microinverters EP20OG101-M24OUS00 EP20OG101-M24OUS01 ENCHARGE-3-1P-NA, ENCHARGE-10-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-iP-NA SC200D111C240US01, SC200G111C240US01 IQBATTERY-5P-IP-NA 2. For information about IQ Combiner 5/5C compatibility with the 2nd-generation batteries, refer to the compatibility matrix. 3. IQ Combiner 5/5C comes pre -equipped with COMMS-KIT-02. IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 Accessories C Mobile Connect 4G-based LTE-M1 cellular modem with a 5-year data plan (CELLMODEM-Mi-06-SP-05 for Sprint and CELLMODEM-MI-06-AT-05 for AT&T) CT-200-SOLID 200 A revenue -grade solid core Production CT with <0.5 % error rate (replacement SKU) 40 Circuit breakers BRK-10A-2-240V Circuit breaker, 2-pole, 10 A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2-pole,15 A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 BRK-15A-2P-24OV-B Circuit breaker, 2-pole, 15 A, Eaton BR215B with hold-down kit support BRK-20A-2P-24OV-B Circuit breaker, 2-pole, 20 A, Eaton BR220B with hold-down kit support CT-200-CLAMP 200 A clamp -style consumption and battery metering CT with <2.5% error rate (replacement SKU) IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 BLUE RAVEN SOLAR DRAWING NUMBER: SS ENPHASE DATA SHEET IQ Gateway IQ Gateway IQ Gateway integrates revenue grade PV production metering (ANSI C12.20 ±0.5%), consumption ENV-IQ-AMi-240 metering (±2.5%), and battery metering (±2.5%) with IQ Battery 5P. ENV2-IQ-AM1-240 (IEEE'1547:2018) Includes one 200 A continuous rated Production Current Transformer (CT). Mobile Connect Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan COMMS-CELLMODEM-Ml-06 4G based LTE-M1 cellular modem with 5-year Sprint data plan CELLMODEM-M1-06-SP-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan CELL MODE M-M1-06-AT-05 Consumption monitoring CT and IQ Battery 5P metering CT CT-200-SPLIT Split -core and clamp style CTs with 2.5% accuracy enable whole home and IQ Battery 5P metering CT-200-CLAMP Communications Kit Installed at the IQ Gateway. For communications with IQ Battery and IQ System Controller. Includes COMMS-KIT-01 USB cable for connection to IQ Gateway or IQ Combiner and allows wireless communication with IQ COMMS-KIT-02 Battery and IQ System Controller. AC power requirements 120/240 V,120/208Y V, or 127/220Y V. Three -wire. 60 Hz. IQ Gateway breaker 2-pole and maximum 20 A overcurrent protection required QGateway Typical power consumption 5 W The IQ Gateway delivers solar production and energy consumption data to Enphase Installer Portal monitoring and analysis software for comprehensive, remote maintenance, and management of Enphase systems. With integrated production metering and optional consumption monitoring, the IQ Gateway is the platform for total energy management. It integrates with the IQ System Controller and IQ Battery. IQ Series Microinverters The high-powered smart grid -ready IQ Series Microinverters (IQ6, IQ7, and IQ8 Series) dramatically simplify the installation process. IQ System Controller Provides microgrid interconnect device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid power to backup power. IQ Battery IQ Load Controller All -in -one AC coupled storage system that is Helps prioritize essential appliances reliable, smart, simple, and safe. It provides during a grid outage to optimize backup capability and installers can quickly energy consumption and prolong design the right system size to meet the needs battery life. of both new and retrofit solar customers. I@ LISTED © 2023 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ and certain other marks listed at https://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. Smart Enables web -based monitoring and control Provides bidirectional communications for remote upgrades Supports power export limiting and zero -export applications Simple Easy system configuration using Enphase Installer App Flexible networking with Wi-Fi, Ethernet, or cellular Reliable Designed for installation indoors or outdoors in a NEMA 3R rated enclosure 5-year limited warranty ENV2-IQ-AM1-240 complies with IEEE®1547:2018 (UL 1741-SIB, 3rd Ed.) IQ-G-DS H-00111-3.0-EN-US-2023-12-20 Number of microinverters polled Up to 300 Dimensions (WxHxD) 21.3cmx12.6cmx4.5cm(8.4inx5inx1.8in) Weight 1.09 lb -40°C to 65°C (-40°F to 149°F) [ENV-IQ-AM1-240] Ambient temperature range -40°C to 50°C (-40°F to 122°F) [ENV2-IQ-AM1-240] -40°C to 46°C (-40°F to 115°F) if installed in an enclosure Environmental rating IP30. For installation indoors or in an NRTL-certified, NEMA type 3R or better -rated enclosure, if installing outdoors. Altitude Up to 2,600 meters (8,530 feet) Integrated Wi-Fi 802.11b/g/n (2.4 GHz, 5 GHz), for connecting the Enphase Cloud via the internet. Wi-Fi range (recommended) 10 m Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included), for connecting to the Enphase Cloud via the internet. Mobile Connect CELLMODEM-M1-06-SP-05, CELLMODEM-MI-06-AT-05 (to be purchased separately, mandatory for sites with IQ Battery) Digital 1/0 Digital input/output for grid operator control USB 2.0 For Mobile Connect and Communications Kit Access point (AP) mode For a connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs, one Production CT, and one battery CT (for IQ Battery 5P) Power line communication (PLC) 90 kHz-110 kHz (Class B), to microinverters. Web API Refer to https://developer-v4.enphase.com Local API Refer to guide for local API LED indicators From top to bottom: Cloud connectivity, Wi-Fi access point mode, PV production state, PLC communications state Configured via Enphase Installer App and Enphase Installer Platform IQ-G-DS H-00111-3.0-EN-US-2023-12-20 BLUE RAVEN SOLAR DRAWING NUMBER: SS Maximum relays read 4 Capabilities supported Power production limiting (Production CT/s required), power export limiting (Production CT/s required and Consumption CT/s - Load with Solar configuration) Minimum IQ Gateway version v7.3.120 Cable configurations 18 AWG, UL-Std. 62,600 V,105°C, and minimum 0.03 inches average thickness Signal voltage range 2.5 V-5 V (digital high), 0 V-1.9 V (digital low) Terminal blocks Five terminals, up to 0.002 in2 Configuration via SCOPEOF DELIVERY Enphase Installer App, Enphase Installer Platform (site settings) Package dimensions (H x W x D) 6.3 in x 10.8 in x 3.9 in Package weight 2.2 lb Aluminium DIN rail 4.9 in Current transformers (CTs) One CT-200-SOLID included CA Rule 21(UL 1741-SA), IEEE' 1547:2018 - UL 1741-SE, 3rd Ed.(ENV2-IQ-AM1-240), UL 61010-1 CAN/CSA C22.2 No. 61010-1 Compliance Title 47 CFR, Part 15, Class B, ICES 003 IEC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 Metering: ANSI C12.20 accuracy class 0.5 (PV production only) IQ System Controller SC200D111C240US01, SC200G111C240US01, EP20OG101-M24OUS01, EP200G101-M240US00 IQ Battery IQBATTERY-5P-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA Microinverter IQ6, IQ7, and IQ8 Series Microinverters 1.8 8.4 ®® All dimensions in inches Accessories Enphase Mobile Connect 4G-based LTE-Mi cellular modem with a 5-Year data plan (CELLMODEM-M1-06-SP-05 for Sprint and CELLMODEM-M1-06-AT-05 for AT&T) CT-200-SOLID 200 A revenue grade solid core Production CT y with <0.5%error rate (replacement SKU) D 8.4 -- III_III, All dimensions in inches Circuit breakers BRK-10A-2-240V Circuit breaker, 2-pole,10 A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2-pole,15 A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2-pole, 15 A, Eaton BR215B with hold-down kit support BRK-20A-2P-240V-B Circuit breaker, 2-pole, 20 A, Eaton BR220B with hold-down kit support CT-200-CLAMP 200 A clamp -style consumption and battery metering CT with <2.5% error rate (replacement SKU) Revision history DSH-00111-3.0 DSH-00111-2.0 DSH-00111-1.0 December 2023 Updated power requirement and added IG Gateway breaker values. August 2023 Updated temperature specification for ENV2-IQ-AM1-240. June 2023 Updated altitude and recommended maximum microinverters on a site. © 2023 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ, and certain other marks listed at IQ-G-DSH-00111-3.0-EN-US-2023-12-20 https://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. IQ-G-DSH-00111-3.0-EN-US-2023-12-20 BLUE RAVEN SOLAR DRAWING NUMBER: SS 1 A,B,C 6.75 [172] .28 [7] (3 HOLES) ,C )CKOUTS 7.50 [191]� n NEMA TYPE 3R ILLUSTRATED A,B,C,D KNOCKOUTS NOTES: FINISH - GRAY BAKED ENAMEL ELECTRODEPOSITIED OVER CLEANED PHOSPHATIZED STEEL. UL LISTED - FILE E-2875 ALL NEUTRALS - INSULATED GROUNDABLE SUITABLE FOR USE AS SERVICE EQUIPMENT TOP OF NEMA TYPE 3R SWITCHES HAVE PROVISIONS FOR MAXIMUM 2 1/2" BOLT -ON HUB. SHORT CIRCUIT CURRENT RATINGS: • 10,000 AMPERES. 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES. 100,000 AMPERES WITH CLASS R FUSES. * FOR CORNER GROUNDED DELTA SYSTEMS. ■ PLUG FUSES $ LUGS SUITABLE FOR 60'C OR 75' CONDUCTORS. FEBRUARY 2014 A,B,C KNOCKOUTS WIRING DIAGRAMS FUSIBLE NOT FUSIBLE I I A C S N I I I p p p B D 0 f 0 b SN TERMINAL LUGS $ AMPERES MAX. WIRE MIN. WIRE TYPE 30 # 6 AWG # 12 AWG AL # 6 AWG # 14 AWG CU KNOCKOUTS SYMBOL A B C D CONDUIT SIZE .50 775 1 1.25 DUAL DIMENSIONS: INCHES MILLIMETERS HORSEPOWER RATINGS CATALOG VOTAGE WIRING 120VAC 240VAC NUMBER RATINGS DIAG. STD. MAX. STD. MAX. 10 10 10 30 10 30 D211NRB9 ■ 240VAC A 1/2 2 1 1/2 - 3 - D221NRB 240VAC A - - 1 1/2 3* 3 7 1/2* D321NRB 240VAC B - - 1 1/2 3 3 7 1/2 DU221RB 240VAC C - - - - 3 - DU321RB 240VAC D - - - - 3 7 1/2 REF DWG #1852 BLUE RAVEN SOLAR DRAWING NUMBER: ss EZf SOLAR making solar simple, A. System Specifications and Ratings JB-1.2, JB-1.XL Specification Sheet PV Junction Box for Composition/Asphalt Shingle Roofs • Maximum Voltage: 1,000 Volts • Maximum Current: JB-1.2: 80 Amps; JB-1.XL: 120 Amps • Allowable Wire: 14 AWG — 6 AWG • Spacing: Please maintain a spacing of at least'/2" between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. • Enclosure Rating: Type 3R • Roof Slope Range: 2.5 — 12:12 • Max Side Wall Fitting Size: 1" • Max Floor Pass -Through Fitting Size: 1" • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: - JB-1.2: UL1741, CSA C22.2 No. 290; JB-1.XL: UL1741, CSA C22.2 No. 290 - Approved wire connectors: must conform to UL1741, CSA C22.2 No. 290 ` �IrtRrtRlS • System Marking: Interek Symbol and File #5019942 5019942 • Periodic Re -inspections: If re -inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. EZ*SOLAR Table 1: Typical Wire Size, Torque Loads and Ratings 1 Conductor 2 Conductor Torque Type NM I Inch Lbs Voltage Current ABB ZS6 terminal block 10-24 awg 16-24 awg Sol/Str 0.5-0.7 6.2-8.85 600V 30 amp ABB ZS10 terminal block 6-24 awg 12-20 awg Sol/Str 1.0-1.6 8.85-14.16 600V 40 am ABB ZS16 terminal block 4-24 awg 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 amp ABB M6/8 terminal block 8-22 awg Sol/Str .08-1 8.85 600V 50 amp Ideal 452 Red w,e o tea, 8 18 awg Sol/Str Self -Torque Self -Torque 600V Ideal 451 Yellow wre�o ate, 10-18 awg Sol/Str Self -Torque Self -Torque 600V Ideal, In -Sure pu=m`G0n ` 10-14 awg Sol/Str Self -Torque Self -Torque 600V WAGO, 2204-1201 10-20 awg 16-24 awg Sol/Str Self -Torque Self -Torque 600V 30 amp WAGO, 221-612 10-20 awg 10-24 awg Sol/Str Self -Torque Self -Torque 600V 30 amp Dottie DRC75 6-12 awg Sol/Str Snap -In Snap -In ESP NG-53 4-6 awg Sol/Str 45 2000V 10-14 awg Sol/Str 35 ESP NG-717 4-6 awg Sol/Str 45 2000V 10-14 awg Sol/Str 35 Brumall 4-5,3 4-6 awg Sol/Str 45 2000V 10-14 awg Sol/Str 1 5 Table 2: Minimum wire -bending space for conductors through a wall opposite terminals in mm (inches) Wire size, AWG or kcmil (mm2) Wires per terminal (pole) 1 2 3 4 or More mm (inch) mm (inch) mm (inch) mm (inch) 14-10 (2.1-5.3) Not Specified - - 8 (8.4) 38.1 (1-1/2) 6 (13.3) 50.8 (2) PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COM EZf SOLAR making solar simple. ITEM NO. PART NUMBER DESCRIPTION OTY 1 JB-1.2 BODY POLYCARBONATE 1 WITH UV INHIBITORS 2 POLYCARBONATE 1 JB-1.2 LID WITH UV INHIBITORS 3 #10 X 1-1/4" PHILLIPS 6 PAN HEAD SCREW 4 #8 X 3/4" PHILLIPS PAN HEAD SCREW 6 [27?.68mm] _276.301Tim] 11,01 irr to-0n, 4-- wl 4 1 II SOLAR II i J&1 2 I i Patents:a 1,,protlu .c /patents i 1 [ 183.06mm] 7.21 in [265.18mm] 10.441n PHONE:385-202-4150 WWW.EZSOLARPRODUCTS.COM SIZE B DWG. N0, JB-112 REV SCALE:1:2 WEIGHT:1.45 LBS SHEET 10F 3 TORQUE SPECIFICATION: 15-20 LBS UL 1741, NEMA 31R CERTIFICATION: CSA C22.2 NO.290 WEIGHT: 1.45 LBS PROPRIETARY AND CONFIDENTIAL:THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUTTHE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. BLUE RAVEN SOLAR DRAWING NUMBER: SS RIGID PVC CONDUIT FITTINGS JB444 JUNCTION BOXES ISSUE DATE: DATE D'EMISSION: 2009 04 30 RIGID PVC CONDUIT FITTINGS SUPERCEDES: REMPLACE: 2004 07 15 JB444 JUNCTION BOXES 5 4.010 (102mi C 31--I B IIF D --30H PRODUCT CODE PART NUMBER I NOMINAL SIZE I A I B C (in) (mm) I (in) I (mm) I (in) I (mm) I (in) I (mm) 076668 J444 STAHLIN 4 103 3.675 93 4.000 102 3.450 88 076259 AMJB444 ALLIED 4 103 3.675 93 4.000 102 3.450 88 077643* 2037-424T CANLET 4 103 3.675 93 4.000 102 3.450 88 077696 JB 444 4 103 4.000 101 4.395 112 3.950 101 PRODUCT CODE PART NUMBER I NOMINAL SIZE I D I E VOLUME (in) (mm) I (in) I (mm) (in) I (mm) (cu. In) (cu. Cm) 076668 J444 STAHLIN 4 103 4.180 106. 3.850 98 51.5 844.6 076259 AMJB444 ALLIED 4 103 4.180 106 3.850 98 51.5 844.6 077643* 2037-424T CANLET 4 103 4.180 106 3.850 98 51.5 844.6 077696 JB 444 4 103 4.170 106 3.930 100 51.5 844.6 PRODUCT CODE PART NUMBER NOMINAL SIZE GASKET CODE INSERT I CODE SCREW I CODE MYEET CODE (in) (mm) 076668 J444 STAHLIN 4 103 072538 (4) 076259 AMJB444 ALLIED 4 103 072538 (4) 077643* 2037-424T CANLET 4 103 072538(4) 077696 JB 444 4 103 097731 072538(4) 072539 (2) 072522(4) 097747 072513 (2) BOX WITH MOLDED MOUNTING FEET, INSERT ONLY; NO COVER, OR GASKET, UL LISTED 576J Page: CONDUIT — 41.1 COVER DIMENSIONS 4.010" ISSUE DATE: I - 0 BLUE RAVEN DATE D'EMISSION: 2009 04 3 SOLAR SUPERCEDES: I I REMPLACE: 2004 07 15 0.245" y (6 mm) 190" D IA 511 na II Mounting Feet oduct Code 097747 DRAWING NUMBER: Page: CONDUIT — 41. Heyco®-Tite Liquid Tight Cordgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW The Ultimate in Liquid Tight Strain Relief Protection `�PR000CT! GLAND PART NO. DESCRIPTION PART DIMENSIONS CONFIGURATION Q/SP A B C D E Conductors or Clearance Max. O.A. Thread Wrenching Nut Type Size No. Black 911�s Hole Die. Length Length Thickness Flat Size mm. in. Immin. Imm. in.1mm in.lmm. in.1mm. Oval Gland Q Cable I6,1 x 9,7I 1 IM3231GCZ I LTCG 1/2 6.1x9.7MM Q/snl .875I22,2I1.70I43,2I.61 115,51 .21 15,3I .98I24,9 Break•Thru Sldnnpd Owtr Gland ° Craven 5,1 xg Tl $ I IeiOA sMi SMOG +s 2.6., .rMkt 3.9 &VIJIwaiE6A.11 j00,ei,62I,s.7 25 6-4 r 34 33.0 Graur.l , 1�.31AIA Metal Locknuts INCLUDED. SEALING NUT INTEGRAL SEALING RING SUGGESTED CLEARANCE HOLE FOR NONTHREADED MOUNTING Material Nylon 6/6 with TPE Sealing Gland Certifications © Listed under Underwriters' Laboratories File E504900 &P CSA Certified by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40oF (-40oC) to 239°F (115°C) Dynamic -4°F (-20oC) to 212°F (100°C) IP Rating IP 68 ALL NEW PRODUCT! Heyco° Helios UVX Clip - Blind Mount PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOUNTING OVERALL RANGE HOLE DIA. HEIGHT Minimum Maximum 1-2 Wires A C in. i n in. I mm. in. mm. in. mm. 1-2 Wires 028 0,7 .250 6,4 23 (5,8 mm) - .32 (8,0 mm) S6520 Helios UVX Clip 100 Pack 260 6,6 .96 24,4 each cable S6560 Helios UVX Clip Bulk A MOUNTING HOLE Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4°F (-20°C) to 185°F (85°C) 1-800-526-4182 • 732-286-1800 (NJ) • FAX: 732-244-8843 • www.hoyco.com • Two new cordgrips now accommodate the Enphase 0 Cable - M3231 GCZ (1/2-NPT) and M3234GDA-SM (3/4- N PT). • The 1/2-version provides liquid tight entry for one Enphase 0 Cable - .24 x .38-(6,1 x 9,7 mm). • The 314-version provides liquid tight entry for up to two Enphase 0 Cables - , 4 x ,38' (6.1 x 9,7 mm) and an additional -130" (3,3 mm) dia. hole far a 08 solld grounding cable- • The 314-version utillZes our skinned - over technology so any unused holes will retain a liquld tight seal, • Rated for use with DG Cable. • The jersey pine tree mounting style installs easily with superior holding power. • UVX nylon protects from corrosion due to outdoor exposure. • Installs into .260-(6,6 mm) mounting hole. • Holds up to 2 cables between .230 - .315-(5,8 - 8,0 mm) each. • Cables install with fingertip pressure. • Molded from our robust UVX nylon 6/6 with extended UV capabilities for our Solar 20 Year Warranty. 1-4b BLUE RAVEN SOLAR DRAWING NUMBER: SS SFM II T— I L 1 1 —r I I 1,§i *&* 4 2 INSTALLS PER DAY Make two installs per day your new standard. SFM INFINITY has fewer roof attachments, one tool installation, and pre -assembled components to get you off the roof 40% faster. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, with integrated front trim, trim end caps, dark components, and recessed hardware. MAXIMUM POWER DENSITY Easily mix module orientations to achieve optimal power density without incurring the increased bill of materials, labor, and attachments required by rail. SYSTEM OVERVIEW NAME TRIMRAIL DESCRIPTIONPART Structural front trim provides aesthetic and aligns modules. TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof. Available for comp shingle or tile. MODULE CLIPS Secure modules to TRIMRAIL. MICRORAIL Connects modules to SLIDERS. Provides post -install array leveling. SPLICE Connects and supports modules. Provides east -west bonding. ATTACHED SPLICE also available. SLIDER FLASHKIT Roof attachment and flashing. Available for comp shingle and tile. BONDING AND ACCESSORIES IKAL LAR STARTS HERE L.270 ��.. 20% FEWER ATTACHMENTS Save time and money on every project: SFM INFINITY requires fewer attachments than rail systems. SFM INFINITY 15 Attachments RAIL 20 Attachments 30% LOGISTICS SAVINGS With fewer SKUs and compact components, SFM INFINITY is easier to stock, easier to transport, and easier to lift to the roof. Plus, make more efficient use of your vehicle fleet. TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules N/S BONDING CLAMP Electrically bonds rows of modules Ono • • BLUE RAVEN SOLAR DRAWING NUMBER: SS mr ----- SFM FRAME SYSTEM BONDING& GROUNDING 19 me M1CR0RA1LTM ----------------------------------------------------------- INSTALLATION GUIDE � PAGE Star Washer is Single Use Only TERMINAL TORQUE, Install Conductor and torque to the followir 4-6 AWG: 35in-lbs 8 AWG: 25 in-lbs 10-14 AWG: 20 in-lbs LUG DETAIL & TORQUE INFO Rsco Lay -In Lug (GBL-4DBT) • 10-32 mounting hardware • Torque = 5 ft-lb • AWG 4-14-Solid or Stranded TERMINALTORQUE, Install Conductor and torque to the following: 4-14 AWG: 35in-lbs LUG DETAIL & TORQUE INFO Ilsco Flange Lug (SGB-4) • 1/4" mounting hardware • Torque = 75 in -lb • AWG 4-14-Solid or Stranded WEEBLUG Single Use Only *4144 TERMINALTORQUE, Install Conductor and torque to the following: 6-14 AWG: 7ft-lbs LUG DETAIL & TORQUE INFO Wiley WEEBLug (6.7) • 1/4" mounting hardware • Torque = 10 ft-lb • AWG 6-14-Solid or Stranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION System bonding is accomplished through modules. System grounding accomplished by attaching a ground lug to any module at a location on the module specified by the module manufacturer. E-W BONDING PATH: E-W module to module bonding is accomplished with 2 pre -installed bonding pins which engage on the secure side of the MicrorailTM and splice. N-S BONDING PATH: N-S module to module bonding is accomplished with bonding clamp with 2 integral bonding pins. (refer also to alternate method) 000 Alternate method Z_77_� TRIMRAIL BONDING PATH: Trimrail to module bonding is accomplished with bonding clamp with integral bonding pin and bonding T-bolt. (refer also to alternate method) BLUE RAVEN SOLAR DRAWING NUMBER: SS " SFM FRAME UL CODE COMPLIANCE NOTES'20 ------------- MICRORAILTM ME----- ----------------------------------------------------------- INSTALLATION -GUIDE-'- PAGE SYSTEM LEVEL FIRE CLASSIFICATION The system fire class rating requires installation in the manner specified in the SUNFRAME MICRORAIL (SFM) Installation Guide. SFM has been classified to the system level fire portion of UL 1703. This UL 1703 classification has been incorporated into the UL 2703 product certification. SFM has achieved Class A, B & C system level performance for low slope & steep sloped roofs when used in conjunction with type 1 and type 2 modules. Class A, B & C system level fire performance is inherent in the SFM design, and no additional mitigation measures are required. The fire classification rating is valid for any roof pitch. There is no required minimum or maximum height limitation above the roof deck to maintain the Class A, B & C fire rating for SFM. SUNFRAME MICRORAILTM components shall be mounted over a fire resistant roof covering rated for the application. Module Type I Roof Slope i System Level Fire Rating Microrail Direction Module Orientation Mitigation Required Type 1 and Type 2 Steep Slope & Low Slope Class A, B & C East-West Landscape OR Portrait None Required UL2703 TEST MODULES See pages 22 and 23 for a list of modules that were electrically and mechanically tested or qualified with the SUNFRAME MICRORAIL (SFM) components outlined within this Installation Guide. • Maximum Area of Module = 27.76 sqft • UL2703 Design Load Ratings: a) Downward Pressure - 113 PSF / 5400 Pa b) Upward Pressure - 50 PSF / 2400 Pa c) Down -Slope Load - 21.6 PSF / 1034 Pa • Tested Loads: a) Downward Pressure - 170 PSF / 8000 Pa b) Upward Pressure - 75 PSF / 3500 Pa c) Down -Slope Load - 32.4 PSF / 1550 Pa • Maximum Span = 6ft • Use with a maximum over current protection device OCPD of 30A • System conforms to UL Std 2703, certified to LTR AE-001-2012 • Rated for a design load of 2400 Pa / 5400 Pa with 24 inch span • PV modules may have a reduced load rating, independent of the SFM load rating. Please consult the PV module manufacturer's installation guide for more information • Down -Slope design load rating of 30 PSF/ 1400 Pa for module areas of 22.3 sq ft or less BLUE RAVEN SOLAR DRAWING NUMBER: SS No=----- 'SFMFRAME COMPATIBLE MODULES; 28 on ------------- MICRORAIL------------------------------------------------------- TM SYSTEM- CERTI-FICATION-'- PAGE Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SFM system. Manufacture Module Model / Series P-Series ALeo DNA-120-(BF/MF)26, DNA-144-(BF/MF)26 Aptos DNA-120-(BF/MF)10-440W, DNA-108-(B F/M F)10-400W CHSM6612P, CHSM6612P/HV, CHSM6612M, Astronergy CHSM6612M/HV, CHSM6610M (BL)(BF)/(HF), I CHSM72M-HC AXN6M610T,AXN6P610T Auxin AXN6M612T & AXN6P612T AXlblackpremium 60 (35mm), AXlpower 60 (35mm), Axitec AXlpower 72 (40mm), AXlpremium 60 (35mm), AXlpremium 72 (40mm). BVM6610, Boviet BVM6612 BYD P6K & MHK-36 Series CS1(H/K/U/Y)-MS CS3(K/L/U), CS3K-MB-AG, CS3K-(MS/P) CS3N-MS, CS3U-MB-AG, CS3U-(MS/P), CS3W Canadian Solar CS5A-M, CS6(K/U), CS6K-(M/P), CS6K-MS CS6P-(M/P), CS6U-(M/P), CS6V-M, CS6X-P Centrosolar America C-Series & E-Series CT2xxMxx-01, CT2xxPxx-01, CertainTeed CTxxxMxx-02, CTxxxM-03, CTxxxMxx-04, CTxxxHC11-04 Dehui DH-60M Eco Solargy Orion 1000 & Apollo 1000 Manufacture Module Model / Series ET-M672BHxxxTW Manufacture Module Model / Series ET Solar LGxxxN2T-A4 FF-MP-BBB-370 Freedom Forever FF-MPI-BBB-xxx, FF-MP-BBB-xxx, A1C E1C E1K LGxxx ( / / /N1C/N1K/N2T/N2W/ Q1C/Q1K/S1C/S2W)-A5 FreeVolt Mono PERC LGxxxN2T-B5 GCL GCL-P6 & GCL-M6 Series LGxxxN1K-B6 LGxxx(A1 C/M 1 C/M 1 K/N 1 C/N 1 K/Q1 C/01 K/ TD-AN 3, TD-AN4, Hansol UB-AN1, UD-AN1 LG Electronics QAC/QAK)-A6 LGxxx(N1C/N1K/N2T/N2W)-E6 36M, 60M, 60P, 72M & 72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 Heliene 144HC M6 Monofacial/Bifacial Series, LGxxxN2T-J5 144HC M10 SL Bifacial LGxxx(N1K/N1W/N2T/N2W)-L5 HT60-156(M) (NDV) (-F), LGxxx(N1C/Q1C/Q1K)-N5 HT Solar HT 72-156(M/P) LGxxx (N1C/N1K/N2W/Q1C/Q1K)-V5 Hyundai KG, MG,TG, RI, RG,TI, MI, HI & KI Series H iA-SxxxHG LR4-60(H I B/H I H/H PB/H PH)-xxxM ITEK iT iT-HE & iT-SE Series LR4-72(HIH/HPH)-xxxM Japan Solar JPS-60 & JPS-72 Series_ LR6-60(BP/HBD/HIBD)-xxxM (30mm) LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35mm) LONG LR6-60(BK)(PE)(PB)(PH)-xxxM (40mm) JAP6 60-xxx,JAM6-60-xxx/SI,JAM6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM (30mm) xxx, JAP6(k)-72-xxx/4BB, JAP72SYY-xxx/ZZ, LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM JAP6(k)-60-xxx/4BB, JAP60SYY-xxx/ZZ, (35mm) JASoLar JAM6(k)-72-xxx/ZZ,JAM72SYY-xxx/ZZ, LR6-72(BK)(HV)(PE)(PB)(PH)-xxxM (40mm) JAM 6(k) -60-xxx/ZZ, JAM 60SYY-xxx/ZZ. i. YY: 01, 02, 03, 09,10 Meyer Burger Meyer Burger Black Meyer Burger White ii. ZZ: SC, PR, BP, HiT, IB, MW, MR Mission Solar Energy MSE Series Mitsubishi MJE & MLE Series JKM & JKMS Series Jinko Eagle JKMxxxM JKMxxxM-72HL-V Neo Solar Power Co. D6M & D6P Series Kyocera I KU Series • Unless otherwise noted, all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 15 for further information BLUE RAVEN SOLAR DRAWING NUMBER: SS No=----- 'SFMFRAME COMPATIBLE MODULES; 29 on ------------- MICRORAIL------------------------------------------------------- TM SYSTEM- CERTI-FICATION-'- PAGE Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SFM system. Manufacture Module Model / Series EVPVxxx (H/K/PK), VBHNxxxSA15 & SA16, VBHNxxxSA17 & SA18, Panasonic VBHNxxxSA17(E/G) & SA18E, VBHNxxxKA01 & KA03 & KA04, VBHNxxxZA01, V13HNxxxZA02, VBHNxxxZA03,VBHNxxxZA04 Peimar SGxxxM (FB/BF) Phono Solar PS-60, PS-72 Prism Solar P72 Series Plus, Pro, Peak, G3, G4, G5, G6(+), G7, G8(+) Pro, Peak L-G2, L-G4, L-G5, L-G6, L-G7 OYEAK DUO BLK-G6+ Q.PEAK DUO BLK-G6+/TS Q.PEAK DUO (BLK)-G8(+) OYEAK DUO L-G8.3/BFF O.Cells OYEAK DUO (BLK) ML-G9(+) Q.PEAK DUO XL-G9/G9.2/G9.3 Q.PEAK DUO (BLK) ML-G10(+) OYEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Q.PEAK DUO BLK ML-G10+ / t Q.TRON BLK M-G2+ SERIES Alpha (72) (Black) (Pure) RECxxxAA (PURE-R) (Pure-RX) RECxxxNP3 Black N-Peak (Black) REC N-Peak 2 (Black) PEAK Energy Series PEAK Energy BLK2 Series PEAK Energy 72 Series Manufacture Module Model / Series TwinPeak Series TwinPeak 2 Series TwinPeak 2 BLK2 Series REC (cont.) TwinPeak 2S(M)72(XV) TwinPeak 3 Series (38mm) TP4 (Black) Renesola Vitrus2 Series & 156 Series Risen RSM72-6 (MDG) (M), RSM60-6 SEG-xxx-BMD-HV SEG Solar SEG-xxx-BMD-TB S-Energy SN72 & SN60 Series (40mm) Seraphim SEG-6 & SRP-6 Series Sharp NU -SA & NU -SC Series SLA, SLG, BC Series & SlLxxx(BL/NL/NT/HL/ Silfab M L/B K/N X/N U/H C/Q M) SE-166*83-xxxM-120N PowerXT-xxx R-(AC/P D/B D) Solarever USA Solaria PowerXT-xxxC-PD PowerXT-xxxR-PM (AC) Sunmodule Protect, SOLarWorLd Sunmodule Plus SS-M-360 to 390 Series, SS-M-390 to 400 Series, Sonali SS-M-440 to 460 Series, SS-M-430 to 460 BiFacial Series, SS 230 - 265 SunEdison F-Series, R-Series & FLEX FXS Series Suniva MV Series & Optimus Series Manufacture Module Model / Series A -Series A400-BLK , SPR-MAX3-XXX-R, X-Series, E-Series & P-Series, SunPower Axxx-BLK-G-AC, SPR-Mxxx-H-AC SPR-Mxxx-BLK-H-AC Suntech STP, STPXXXS - B60/Wnhb TP572, TP596, TP654, TP660, Talesun TP672, Hipor M, Smart SC, SC B, SC 131, SC B2 Tesla TxxxH,TxxxS PA05, PD05, DD05, DE06, DD06, PE06, Trina PD14, PE14, DD14, DE09.05, DE14, DE15, PE15H UNlxxx-120M-1313, UN1xxx-120MH, Universal Solar UNlxxx-108M-1313, U P-M xxx P(- B), Upsolar UP-MxxxM(-B) D7MxxxH7A, D7(M/K)xxxH8A United Renewable Energy FAKxxx(C8G/E8G), FAMxxxE7G-BB (URE) FAMxxxE8G(-BB), FBMxxxMFG-BB URECO F6MxxxE7G-BB Eldora, Vikram Solivo, Somera VSUNxxx-(108/120)M-BB VSUN VSUNxxx-108BMH Waaree AC & Adiya Series Winaico WST & WSP Series YingLi YGE & YLM Series ZN Shine ZXM6-72, ZXM6-NH144-166_2094 • Unless otherwise noted, all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 15 for further information BLUE RAVEN SOLAR DRAWING NUMBER: SS Lntertek Total QuahLy. Assured. AUTHORIZATION TO MARK This authorizes the application of the Certification Mark(s) shown below to the rnodets described in the Product(s) Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified on the aarrelalion page of the Listing Reporl, This documenl is the property of Intertek Testing Services and is not transferable- The certification mark(s) may be applied only at the location of the Party Authorized To Apply Mark. Applicarst: Unirac, Inc Manufacturer. 1411 Broadway Blvd NE Address'. Albuquerque, NM 87102 Address: Country: USA Country: Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: lnlertek Testing Services NA, Inc_, Lake Forest, CA Control Number; $003705 Authorized by: far L Matthew Snyder, Certifleation Manager CO3jus T Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number_ T" AWWWLMbCn la uWk rF kd IM 4WS"wi Wse 9r WNFW►ti CA" Oft hh W994 /G PtrtwM % OW r� n.�w{.. t+rF+yin 111*tW Intl 11r W Ilrrt UW W "i FWP°�*"I04 OM UW�Jdy inLW IC Ihn kreei" 4Yd W* W MO WWWA. IM t* ptyrni} ►* LWfit Ip any Put'. OVW 11W5 #t 0449la i MWXnra Wdh IM #pr4PrrMM W XTF k 4s. r4or4i or dWnsp oorswr and OV 11r4 use of Vw+rwl *wjiiM b ChM% 011r 11Fh Caww h #LMe4ziW hp pwm cmffg or *W&Aix N WO Ault oibm b Mm'i irk Pan mug+a J%&"Wg Lin of inmebA'■ C#n� nark o 'wr*W to" oM aoftt IM are w IM w{ "Kwrt wW In 11W ALAForWLlkn b WrA Aft T~ wo of1M hn9Nrlpk it m ke •w ;alp a' pdr}'Lat nar 4 U Rw IiWod ffivW&M Fdo l-A w bwr -ft urL,hd , 7 be &DWoriW in x+ififg by i'da* k lmiUdt Ftehxji A7 auffwnEi eed FOYnn up Sbrvieei am fix th6 purpam ai aivrlho aDWoWwm umge or Me G@ W_ri7n nnxk Ln awYdmm* "M i M R,rr They oro rm for ih* phrp� or prodrkiin qmkty mrWd wd da not rmb s ■re Ord of 4reu abWohon in Uh r %Md lnterte6L Testing Services NA Inc. 545 Easi Algonquirh Road, Arlington Helghis. IL 60006 Telephore $00-345-3851 at $47-439-5667 Fax 312-283-1672 Mountirg Systems, Mounting Devices, Ciampi ngiRetenbon devices, and Ground Lugs for Use with Flat- Standard(s): Plate Photovoltaic Modules and Panels [UL 2703.2016 Ed- t+R:24Mar2021] PV Module and Pane] Racking Mounting System and Accessories (CSA TIL No. A-40,20201 Product: Phutovoltair, Mounting System, Sun Frame Micro r;�it InsWIllation Guido. PUB2023MAY1 Q Brand flame: Unlrac Models: Unirac SFIV ATM for Report 102393982LAX-002 Page 1 of 4 tneek Total Quallryr. ASYLIM& AUTHORIZATION TO MARK This authorizes the application of the Certification h+Mark{s) shown below to the models described In the Pfoducl(s) Covered section whin made in accordance with the conditions set forltl in the Certification Agreement and Listing Report. This authorization also applies to multiple listee modef(si identified on the correlation page of the Listing Report, This document is that property of Interlek Testing Services and is net transferable- The certift alion mark(s) may be applied only at the location of the Party Authorized To Apply Mark, Applicant: Unirac, Inc Manufacturer. 1411 Broadway Slvd NE Address: Albuquerque, NM 87102 Address: Country: USA Country: Party Authorized To Apply Mark: Some as Manuracturer Rupert Issuing Office: Intertek Testing Services NA, Inc., Lake Forest. CA Control Number. 5074989 Authorized by: for L. Watihew Snyder Certification Manager C US Intenek This document supersedes all previous Authorizations to Mark for the noted Report Numl*er. Th* AMPOKcM M is Wt o W W& uW ar IMyM M CUM aria 4 Pn~ P+Y4Y4+M 10" r-W%-0l-`n #Wffff r 4 04tnora Y WdA SW Its U*% pY "'o r4lfpaaitAtyWW y"kdr rs hdAntl io Me imrLi • id aX46DO if an aLpnan*M- IM PHA OPKA 1M nb ILLLh+W b WW PtMR WW *M b 1I4 CMW Lit trxwgruy W nh 7n %, rV FW ". VVWW a dMMP QMXPaW N V* Use or M A47erri ftM k Ilrrk. Orrr/ p1t CUM it IIWt4dM hu 1M" cc 40r16U w U fki AuftwMbm b M06 mW Ow wPf In 14 dnh'ily. L%P of IrftMk a r,*MrcgbWh MM h rL04W b will OW"W trL LF14ot Id ft jVYrYhl+d W4In r i AmWollrnrar la AMF* Any 1W'MYf ut! W MLt M mh nimin W 1tLrr belt or idN+q wd Vr ay Wed miL6rjl. "ICI Qe m rAm mirk ArLL be apPlmaA hh y/Ili69 by iMerlek IrWig Fad wp Ammft,.m end Follew rp Smiicw w by 9rt p opm of Y6rrhq Appnp6j" ue Me Vr ft C401ina riina mri h} rrnarmy" wM Lhe rrrowri. the} err"for the purpo & p'odumon VurFLy Dw&cA oral da not pzm� tie Cbm ar ■" o e<In win rww�rt Intertak Testing Services NA Inc. 545 Easl Algoriqulri Road, Arlington Hatghis, IL 60005 Telephone 800 345-3851 or $47439-5657 Fax 312-283-1672 Mounting Systems, Mounting Devices, Clam pinglRetention Devices, and; Ground Lugs for Use %vil3r F;al- 5tandard(s): Plate Photovoltaic Modules and Panels [UL 2703.2015 Ed.i+R;24Mar202Ij PV Module and Panel Racking Mounting System and Accessories (CSA T1L No_ A-40:20201 Product: Photovoltaic Mounling Sy5;lurn, Sun Frame tblF.Forail Installation Guide. PUB2023MAYID _Brand Name- Unirac Models; Unirac SFM ATM Issued: 17-May-2023 ATM fof Report 102393982LA]t-002 ED 15 3 13 L1 JtJ-A22i Mw dak" Page 2 of 4 ATM Iss t&d: 17-May- 0 3 E4iL3.F5it,Ak2m?UaN* hr BLUE RAVEN SOLAR DRAWING NUMBER: SS tne ek AUTHORIZATION TO MAR total Quality_ Assured. This authorizes the application of the Certification Mark(s) shown below to the models described en the Product(s) C*varod section whin made in accprdan( l3 with the cClndltions set. Forth in the Certification Agreement and Listing Report_ This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing Report. This document is the property of Inlertek Testing Sarwces and is not transferable. The carlOication ma1-k(s) may be applies{ only at the location of the Party Authorized To Apply MarR, Applicant: Unirac, Inc Manufacturer: 1411 Broadway Blvd NE Address: Albuquerque. NM 8710.2 Address: Country: USA Country: Party Authorized To Ap•pfy Mari[: Same as Manufacturer Report Issuing Office: Intertek Testing Services NA, Inc_, Lake Forest. CA Control Number. $019 .51 Authorized by: For L. Matthew Snyder, Certification Manager C us e:MIT 1 Intertek This document supemedes all previous Authorizations to Mark for the noteli Report Number, Th.% A.ulhcnza•,an to mirk is for I" dxdk LWV M4 al 1rbk1Dk'& rbwl erd a pra,dW pu uwh 1p Uw Q4rW z0pn rRawoft DWWAMn bo~ and ils CWnt Isly{leky ht*W"thy w.6 L6b4ft an Iinrletl to me bean and auwh rw0 Me49np~ InlprL" ar$wurw4 np hpJX1q da Pn9 p". oUW rrru hp go CIWJ in aeeorOrus %M ftr7lKn�. la eTY lter. BzMex e+ tlrembope oeeepyyy by uw usy rk era ALWMnrAHtl do 1firk C�1?y VW Cb e w arMtrenred in purrM cnpyep w 4"Idbcn Cr Me AWWWlxraen is Abbe W4 Parr"yr he anhmty. Ube of 10sei4a'F CWlinnaw ftwk rt resLrcL d 4p the eordg : sad W l In the aV*~ eao n N4e Ar$wur0j0M $9 rLur .Any tdrpwr v W 41 PW W*614 t FA M fir Me ee4 Cr QOMMWpntt'a of the Iealed r' W~ [. dua IW S*N?f b fr o One fr appowr d in wnbng by Lrderiek. Inihol Foebrie AswLso card arm Fotlow by Hardon are for the rMwp:Pn orwr" appeoprWr lemon or the C&brrwubn rtmk m womnmw* draIM agrwrrml, they m no1 for the purposes a1 pro&x m quWrly [enact raid do not retie tr aw rbwd al Prey DbligaWtm n thk r=pW& lntertsk Testing Services NA Ina 645 East Algonquin Road. Arlingion Heights, IL 60005 Telephone 800-345-3851 or 847-499-5667 Fax 312-283-1672 Mounting Sys#ems, Mounting DeviCes, ClampinglRetentian Devices, and Ground Lugs for Use with Flat- taridard(a), Plate Photovoltaic Modules and Panels [UL 2703,2015 Ed. 1+R_24Mar2021] PV Module and Panel Lacking Mounting System and Accessories [CSA TIL No_ A-40.2020] Product.: Photovoltaic Mounling System, Sun Frame Microrail installation Guide. PU52023MAY10 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LA -002 Page 3 or 4 ATM Issued- 17-May-2023 ED 16 j 15 11-Jid-79771 RLVA,1t.-, tner ek AUTHORIZATION TO MARK 7ataJQualitV.P cared_ This authorizes the application of the Celiticatlon Mark(s) shown below to the models described in the f rnduct(s) Covered 52Ction when made in accordance with trio condltians set #odor in the Certification Agreement and Listing Deport This authorization also applies to multiple listee mndel(s) identified on the correlation page of the Listing Report. This document is the property of Intertek Testing ;services and is nut transferable. The certificalion mark(s) may be applied only at lire location of the Party Aulhorized To Apply Mark. Applicant: Unirac, Inc Manufacturer: 1411 l3roadway Blvd NE Address. Alhuquarque. t�M 87102 Address: Country: LISA Country: Party Authorized To Apply Mark: Same as Manufacturer Report Issuing OffirNe: Intertek Testing Services NA, InC_. Lake Fart, CA Control Number: 5021866 Authorized by: For L. Matthew Snyder, CerlifiWion Mariager CO(Tus r4m Intertek This document Supersedes all previous Au thonza tFDn s to Mark for the noted Report Number, the AuftA^WMMhp#irkA WpW4nrluar.r Nye ar IrmAnk's EhwO and is Ixpndad p.r nl tpthe rmrnn Um a"nmteKo- Inlartuk dry#Ck+rq. InWtek's rMpyry¢hly" Wkky Yfa 1M14d 44 Ubp bras W4 VW4MaM cr Pm QWWM*M. Ingrpk PSWnPA M 6a tB La arty GWW. ourdr Ilren 10 Iha ChORL in..r., 1a Y eh In* J904 rynl, f r any kkW. ■aamge & &Mdoo Dmwo w.' ty flit 4eM 01 tlYa A•rrtERNOM I* blrrr4 Only Uq OWN h ruMrt+4rbN b permt eQp 4V Or tSQenLulrort ed V" ALtlhonx "i Ia Msrh and Ihdn only d ds errurety use or wwwva CnAaoeam ftdo ir, rFle'4 W 10 ft WOWN WW INA kf the Pffmwo rr rnC i•I Oft A V"'4ff kW to 14VK AJV k9jhW kdla Or P* ktlarwk r for Urn iota a ortvaysrrrml M c Iaalod ardor;I. ged'du[I Ce mr"7. mum ►rrt he Appra`*d En mWq by Wiv%L 11 r1 Fedwy Aaahmwrmok wd Felon Lp 9aurorl o for 1w prrpow of mnh ring arKr Kam usage of um ComhcoLrrn maul in onax wrxr wmi me eprerrrrq PMS' era not for h prrpa•a d papd�r quirgr aaMe1 er.] do r+cA rWlra Pw CYerrt d 7Mrr a In 1[n rarpo�7 Intertek Telling Services NA Inc. W East Algonquin Road, ArIIn$ton Heights, IL 60005 Telephone $00-345-3851 or 847-439-5667 Fax 312-283-1872 Mounting Syslerns, Mounting DaviceF, ClampinglRetention Devises. and Ground Lugs for Use with Rat, Standard{s}: Plate Pholovollaic Modules and Panels [UL 2703,2015 Ed.1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No_ A-40:2020) Product: Photovoltaic Mounting System, Sun Frames Microrail Instalialion Guide. PUB2023MAY10 Brand fume. Unirac Models: Unirac SrM ATM for Deport 102393982LAX-00 Page 4 of 4 ATM Issued: 17-May-20 3 FP 15.1 I $ tt-Akk2M: r.Uiid.i'.,.. BLUE RAVEN SOLAR DRAWING NUMBER: SS i to tek Total Quality, Assured, Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 102393982LAX-002 Oriainal 11-Apr-2016 Revised: 5-Oct-2022 Standard(s) Applicant Address Country Contact Phone FAX Email Manufacturer 3 Address Country Contact Phone FAX Email Manufacturer 5 Address Country Contact Phone FAX Mounting Systems, Mounting Devices, Clamping/Retention Devices, and Ground Lugs for Use with Flat -Plate Photovoltaic Modules and Panels [UL 2703:2015 Ed. 1+R:24Mar2021] PV Module and Panel Racking Mounting System and Accessories [CSA TIL No. A-40:2020] Unirac, Inc 1411 Broadway Blvd NE Albuquerque, NM 87102 USA Klaus Nicolaedis Todd Ganshaw 505-462-2190 505-843-1418 NA klaus.nicolaedis@unirac.com toddg@unirac.com Manufacturer 2 Address Country Contact Phone FAX Email Manufacturer 4 Address Country Contact Phone FAX Email Page 1_of 138 This reporl is for the NXLluiii+e use of Jniertek's Client and a provided pursuant rcK io the agreem `-e - Inlerkk and its Client Interwk'S pon ress944y ana 14*drty ar$ IlrAed tb iI'tb 6Mm& and 04ndgpnS Of the agrim nevi JMer6Ek a". rlo Iiabdf�f to any part'. aRrer tlian W Rye Gam' in ar;4 X nG* wf h tb6 agreement. Ear any loss, expense or nemage cceintonad by me use cd this report Only the Client s aulhonxed to permA mptmg or distnbuLon or tits reaped and then only in ils endresy Any use of the hmertek name or one cd its marks for the sale or adNerlisernent of the iesled malarial. prodtru or service must Iirsl be aplprwed in wnr rg by finertek. The obsetvaboris and test results in 11101 report are relevant Only tO the sample tested ibis report by rl9e4d aces not tmnty that the material, product. of servg4n is Or hen ever been under an Inlertek eeAW--bon program. tntertek Total Quality, Assured. Listing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 102393982LAX-002 Oriainal 11-A r-2016 Revised: 5-Oct-2022 Email Page 2_of 138 This report is for the ew:lu9u a use of Irderte" Client and a prprided pursuant to the agreemem lnetr ee.^. Interlxk and its Client Intertek's respons*41iily ar4 kabaty Ora limited to 1he berms and oandnW& or the agreeniM Jnler6ek assumes no Iiabdrly to any party. shyer thbn to Rye GiE.4 in atpbnS&" with t66 agreembM, kr any kiss, expense or clwnage ccrasNywd by the use ci this report Only the Client s sulhonred to permit copyng or distribution of Ctrs repast and then only in itf OnWety Any use -of 1he tmerlek name or one cd its marks for the sale or a*verlisement or the iesled malarial. product or service must lirsl be aranwaa in wriwq by rmertek. The obsetvanarts and test results in INS report are relevant Only to the sample "tea Skis report b1' neetd aces not inpry Mint the matPnal peadu4y. pr seance a Or bee ever been under an Inlerbek cenit"bon program. BLUE RAVEN SOLAR DRAWING NUMBER: SS Report No. 102393982LAX-002 Unirac, Inc Page 3 of 138 Issued: 11-Apr-2016 Revised: 5-Oct-2022 2.0 Product Description Product Photovoltaic Mounting System, Sun Frame Microrail Installation Guide, PUB2022SEP28 Brand name Unirac The product covered by this report is the Sun Frame Micro Rail roof mounted Photovoltaic Rack Mounting System. This system is designed to provide bonding and grounding to photovoltaic modules. The mounting system employs anodized or mill finish aluminum brackets that are roof mounted using the slider, outlined in section 4 of this report. There are no rails within this product, whereas the 3" Micro Rail, Floating Splice, and 9" Attached Splice electrically bond the modules together forming the path to ground. The Micro Rails are installed onto the module frame by using a stainless steel bolt anodized with black oxide with a stainless type 300 bonding pin, torqued to 20 ft-lbs, retaining the modules to the bracket. The bonding pin of the Micro Rail when bolted and torqued, penetrate the anodized coating of the photovoltaic module frame (at bottom flange) to contact the metal, Description creating a bonded connection from module to module. The grounding of the entire system is intended to be in accordance with the latest edition of the National Electrical Code, including NEC 250: Grounding and Bonding, and NEC 690: Solar Photovoltaic Systems or the Canadian Electrical Code, CSA C22.1 Part 1 in accordance to the revision in effect in the jurisdiction in which the project resides. Any local electrical codes must be adhered in addition to the national electrical codes. The Grounding Lug is secured to the photovoltaic module, torqued in accordance with the installation manual provided in this document. Other optional grounding includes the use of the Enphase UL2703 certified grounding system, which requires a minimum of 2 micro -inverters mounted to the same rail, and using the same engage cable. ED 16.3.15 (1-Jul-2022) Mandatory Report No. 102393982LAX-002 Unirac, Inc Page 4 of 138 Issued: 11-Apr-2016 Revised: 5-Oct-2022 2.0 Product Description Models Unirac SFM Model Similarity NA Fuse Rating: 30A Module Orientation: Portrait or Landscape Maximum Module Size: 17.98 ft2 UL2703 Design Load Rating: 33 PSF Downward, 33 PSF Upward, 10 PSF Down -Slope Tested Loads - 50 psf/2400Pa Downward, 50psf/2400Pa Uplift, 15psf/720Pa Down Slope Trina TSM-255PD05.08 and Sunpower SPR-E20-327 used for Mechanical Loading Increased size ML test: Maximum Module Size: 22.3 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 30 PSF Down -Slope LG355S2W-A5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" UL2703 Design Load Rating: 46.9 PSF Downward, 40 PSF Upward, 10 PSF Down -Slope LG395N2W-A5, LG360S2W-A5 and LG355S2W-A5 used for used for Mechanical Loading test. Mounting configuration: Six mountings for two modules used with the maximum span of 74.5" IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 50psf/2400Pa Uplift Ratings Mechanical Load test to add FlashLoc Slider and Trim Assemblies to UL2703 and IEC 61646 Certifications, & Increase SFM System UL2703 Module Size: Maximum Module Size: 27.76 ft2 UL2703 Design Load Rating: 113 PSF Downward, 50 PSF Upward, 21.6 PSF Down -Slope Jinko Eagle 72HM G5 used for Mechanical Loading test. Mounting configuration: Four mountings on each long side of panel with the longest span of 24" Mamzimum module size: 21.86 ft2 IEC 61646 Test Loads - 112.78 psf/5400Pa Downward, 75psf/3600Pa Uplift SunPower model SPR-A430-COM-MLSD used for Mechanical Loading Fire Class Resistance Rating: - Class A for Steep Slope Applications when using Type 1 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A for Steep Slope Applications when using Type 2 Modules. Can be installed at any interstitial gap. Installations must include Trim Rail. - Class A Fire Rated for Low Slope applications with Type 1 or 2 listed photovoltaic modules. This system was evaluated with a 5" gap between the bottom of the module and the roof's surface See section 7.0 illustractions # 1, 1 a and 1 b for a complete list of PV modules evaluated with these racking systems Other Ratings NA ED 16.3.15 (1-Jul-2022) Mandatory BLUE RAVEN SOLAR DRAWING NUMBER: SS PART # TABLE P/N DESCRIPTION SFMBTLMI SFM DTD BUTYL ATT, MILL 2X #14-14 SCREW, HWH, SS, SELF -DR W/ #14 EPDM WASHER DTD ATTACHMENT O O? 3/4" O O: O O no I V 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM BUTYI 1/8" BUTYL 11, - 2 1/2" PRODUCT LINE: SFM INFINITY DRAWING TYPE: PARTS ASSEMBLY DESCRIPTION: SFM DTD BUTYL ATTACHMENT REVISION DATE: 3/1/2023 PART TABLE P/N DESCRIPTION 004095D FLASHLOC SFM TRIM KIT w/ CAP, 20 PACK 3 3/4" DRAWING NOT TO SCALE ALL DIMENSIONS ARE Q mom U N I RAL NOMINAL , 1411 BROADWAY BLVD. NE PRODUCT PROTECTED BY U- ALBUQUERQUE, NM 87102 USA ONE OR MORE US PATENTS PHONE: 505.242.6411 WWW,UNIRAC,COM LEGAL NOTICE SHEET PRODUCT LINE: SFM DRAWING TYPE: ASSEMBLY DETAIL DESCRIPTION: FLASHLOC SFM TRIM KIT REVISION DATE: 2/2/2021 3/8" x 7/8" HHCS BOLT 3/8 TRI DRIVE NUT O TRIM CAP (2V") DRAWING NOT TO SCALE ALL DIMENSIONS ARE Mo NOMINAL Q PRODUCT PROTECTED BY U- ONE OR MORE US PATENTS LEGAL NOTICE SHEET BLUE RAVEN SOLAR DRAWING NUMBER: ss