PSE FINAL 105104609 TAHOMA TERRA APARTMENTS PH 2 - peer signedN Vicinity Map 46.9453, -122.6275 Owner / Developer Contact Info officeATTN: TAHOMA TERRA HOLDINGS, LLC PO BOX 73790 PUYALLUP, WA 98373 EVAN MANN 253.820.7835 THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) PSE No No No Yes Yes Yes No YesDeveloper "Flagging Required" "Outages Required" "Locates Required" ARE TO BE INSTALLED, CROSS SECTION DETAILS OF THE TYPICAL EROSION STRUCTURES, & SPECIAL REQUIREMENTS FOR WORK IN SENSITIVE AREAS.) EROSION & SEDIMENT CONTROL REQUIREMENTS NOTES DETAILING WHERE EROSION OR SEDIMENT CONTROL STRUCTURES (LOCAL JURISDICTIONS MAY HAVE ADDITIONAL REQUIREMENTS INCLUDING 0150.3200 TECHNIQUES FOR TEMPORARY EROSION & SEDIMENT CONTROL EROSION & SEDIMENT CONTROL SHALL BE PER PSE STANDARD PRACTICE & ANY ADDITIONAL LOCAL JURISDICTION REQUIREMENTS. FOREMAN (CHECK BOX WHEN COMPLETED) PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition. Grid, Cable, and Switch numbers INSTALLED & VERIFIED. Field Changes RED-LINED on As-built. Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE. Foreman's Signature _______________________________________________ Print Name ___________________________________ Date ______________ Material VERIFIED and CHANGES noted on Paperwork. Total PRIMARY Cable noted on As-built. Company ID#'s RECORDED in correct location on As-built. Deviations noted on the As-built and their reason. I certify that the work performed meets PSE's standards and procedures and that all quality requirements are met. GAS PHONE CABLE TV 514615707 105104609 N/A 101185984 N/A 108164006 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A PROJECT PHASE PWR NOTIF#ORDER# Superior Relocation Removal UG XFMR Temporary Job Order Distribution Service Stubs HP Svc/MSA 10 5 1 0 4 6 0 9 N / A DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP J. CALLAHAN 206.503.1520 . A. DUNN . 02.10.25 N/A .N/A S. LEWISON . 02.10.25 REDT # ( RW-134414 )YELM TAHOMA TERRA APARTMENTS PH 2 3Ø PRIMARY U/G LINE EXTENSION - 8 M/F BLDGS, 103 UNITS 14730 TAHOMA BLVD SE (P#78640000010), YELM, WA 98597 PUGET SOUND ENERGY N/A N/A N/A 105104609 N/A 1 OF 4 THURSTON N/A N/A QSTHLE 24SW-T17N-R01E N/A N/A 1701E095 1702E116 1701E095 YEL-25 COMCAST TED AXTELL 253.878.2794 LUMEN DEWAYNE RICHERT 253.221.0133 RIGHT OF WAY LINDA OLSON 425.786.4806 . . . E-Mail: Cell Phone: Project Manager Contact Information: Manager:JESSICA CALLAHAN 206.503.1520 jessica.callahan@pse.com x x x ... ... ... x EVAN@SOUNDBUILTHOMES.COM TYPICAL NOTCH-OUT FOR TRANSFORMER, NOT TO SCALE & SECONDARY PEDESTAL/HANDHOLE BACK OF EASEMENT STANDARD EASEMENT LINE ROW 10' PL 1' 4' - 5' Min. 1' 7'7' TRANSFORMER (WHEN PRESENT) MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE OIL-FILLED EQUIPMENT TRANSFORMER APPROVED AREA CO M B U S T I B L E B U I L D I N G W A L L S & R O O F 10' 10' 10' COOLING 5' MIN 5' MIN 10' MIN 5' MIN FINS ACCESS CONCRETE PAD MINIMUM CLEARANCES FOR PSE EQUIPMENT NOT TO SCALE CURB OR EDGE OF PAVEMENT CURB OR EDGE OF PAVEMENT 5' MIN ROAD OR PARKING AREA TYP. PAD & TRANS- FORMER 3' MIN 3' MIN DOOR ACCESS DOOR REQUIRED WORK SPACE AREA 3' MIN POWER GENERAL NOTES - MULTIFAMILY PROJECT 11. 7. 6. 5. 4. 3. 2. 1. All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy. All switching arrangements and/or outage arrangements are to be made with the Project Manager at least three (3) working days in advance. Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing work to get the underground facilities located. STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk, etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager. SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction materials which would restrict construction and/or equipment access, before work can begin. Roads shall be paved or have a compacted , crushed rock base in place. CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water, storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them. All work is to be done in accordance with local municipal and county permit requirements as applicable. Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits and crossings from the individual unit's meter base to the designated connection point. Inclement weather conditions may cause delays in construction times and dates. EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will provide any and all shoring or they will side slope the trench to 1:1. 8. 9. 10. CLEAR WORKING SPACE FOR VAULTS NOT TO SCALE FIELD SIDE (PREFERRED) ROAD SIDE (PREFERRED) 6' MIN 3' MIN 3' MIN 3' MIN J-BOX CABLE ENTRY DETAIL NOT TO SCALE 12kV CABLE ROUTING Cables should enter the vault so that all of the cables will lay in the same direction. TOP VIEW JOINT TRENCH DETAIL NOT TO SCALE ROAD SIDE MINIPAD MINIPAD FIELD SIDE VAULT 6" of crushed rock (base for vault) P/L Power Secondary Power Primary Communications 42" Min 21"1' Feeder 38" 2" 4" Sand Bedding 12" Sand Cover 36" Cover 4" Sand Bedding 42" 6" Additional depth when Feeder is required PSE 10' FRONTAGE EASEMENT 1' TRANSFORMER Final Backfill Initial Backfill Trench Depth 42" - 48" Phone & TV Primary Power Cable in PSE Provided DB120 Grade Conduit Excavated Dirt Pile Final Grade 24" Min 48" Max 18" Backfill for DB 120 Conduit/Direct Buried Cable 12" Min Separation 6" or 12" of sand, 5/8" minus 3" of sand, 5/8" minus, or clean backfill bedding JOINT TRENCH DETAIL 36" Min Cover ROADSIDE Typical To Excavated Dirt Pile (No Rocks over 10" Diameter) or clean backfill shading Primary-DB120 CONDUIT (NTS) - A 6" layer of sand, 5/8" minus, or clean shading is allowed when excavated native material contains rocks no larger than 8" in diameter. Trench and backfill requirements for primary electric line extension trenches (No PSE gas) - A 12" layer of sand, 5/8" minus, or clean shading is required when excavated native material contains rocks up to 10" in diameter. TOP VIEW Excavation - 10-1/3 cubic yards SIDE VIEW Rock Crushed 6" 4'-4" 2" 8'-0" 4'-8" 3'-6" 4'-8" 6" 20" 4'-8"5'-6" 44" 8'-0" No Secondary PSE Primary Conduit Customer's conduit/cables may enter on any vault side except the front or side where PSE's primary conduit/cable enters. Note: Customer's conduit/cables must match PSE's left/right vault entry orientation and coil in the same direction as PSE's primary conductors. VAULT DETAIL @ V01-V03 NOT TO SCALE MINIMUM CLEARANCES FROM OIL-FILLED EQUIP. TO BLDG. FEATURES NOT TO SCALE FIRE ESCAPE SERVICE GAS RELIEF DOOR, WINDOW, VENT, OR OTHER OPENING TANK FUEL VENT OIL-FILLED ELECTRICAL EQUIPMENT SPRINKLER VALVE, STANDPIPE, OR HYDRANT 20' 3' 10' 6' 10' (TRANSFORMER) Oil-Filled Equipment Clearances per PSE Std 0700.1500 If the oil-filled equipment is adjacent to… Clearance Requirement Combustible walls or roof (including stucco).10 FT Noncombustible walls, soffits, and roofs (including brick, concrete, steel and stone) providing the side of the transformer facing the wall does not have doors. Materials that pass UBC Std. 2-1 or ASTM E136-79 are considered to be noncombustible. 3 FT Fire sprinkler valves, standpipes, and fire hydrants.6 FT Doors, windows, vents, fire escapes, or other building openings.10 FT The water's edge of a swimming pool or any body of water.15 FT Individual domestic and irrigation wells. Clearance not required on pole mounted transformers (pole placement still applies as stated in 6450.3000), TUT's installed in sealed vaults, 7200V single-phase padmount transformers 50kva or less, and ones with reduced flammability oil. 100 FT Facilities used to dispense or store LP, hazardous liquids, or fuel.20 FT Gas service meter relief vent.3 FT Generators, customer-owned transformers, etc.6 FT 2" Excavation - 19-1/2 cubic yards SIDE VIEW 5'-4"Crushed 6" Rock TOP VIEW 9' 11' 7'-0" 4'-0" 1' 4'-8" VAULT DETAIL @ J01 NOT TO SCALE SITE 1 SITE 4 SITE 3 SITE 2 LO N G M I R E S T S E W Y E L M A V E TA H O M A BLV D S E 3.10.25 C C D E F H G D E K H F G J M L B E R R Y V A L L E Y R D S E TA H O M A B L V D S E BLDG H 7 UNITS 1000 SQFT (3) 300KCMIL BLDG G 12 UNITS 1000 SQFT BLDG F 12 UNITS 900 SQFT BLDG E 12 UNITS 900 SQFT BLDG D 12 UNITS 900 SQFT BLDG C 24 UNITS 900 SQFT EX: 2-4" EX: 2-4" EX: 1-4" (6) 300KCMIL (3) 300KCMIL (3) 300KCMIL (3) 300KCMIL (3) 300KCMIL EX: 1-4" 1-4" 3-6" 1-4" 3-6" 1-4" F E E D YEL 25 90' DEVELOPER RESPONSIBLE FOR CONDUIT/WIRE FROM VAULT TO METER LOCATION 24 ' 24 ' 24 ' 24' A B A B C LO N G M I R E S T S E BLDG B 12 UNITS 900 SQFT BLDG A 12 UNITS 900 SQFT (3) 300KCMIL (3) 300KCMIL 3-6" 3-6" 3-4" EX: 1-3" 56 ' 30' 14' 1-4" 1" = 50' DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP J. CALLAHAN 206.503.1520 . A. DUNN . 02.10.25 N/A .N/A S. LEWISON . 02.10.25 REDT # ( RW-134414 )YELM TAHOMA TERRA APARTMENTS PH 2 3Ø PRIMARY U/G LINE EXTENSION - 8 M/F BLDGS, 103 UNITS 14730 TAHOMA BLVD SE (P#78640000010), YELM, WA 98597 PUGET SOUND ENERGY N/A N/A N/A 105104609 1" = 50' 2 OF 4 THURSTON N/A N/A QSTHLE 24SW-T17N-R01E N/A N/A 1701E095 1702E116 1701E095 YEL-25 COMCAST TED AXTELL 253.878.2794 LUMEN DEWAYNE RICHERT 253.221.0133 RIGHT OF WAY LINDA OLSON 425.786.4806 . . . SITE PLAN (1) CIRCUIT LOADING TABLE AS OF EXIST. PEAK LOAD EST. NEW LOAD TOTAL CIRCUIT: A PHASE B PHASE C PHASE YEL-25 12.04.24 467 402 347 29 29 29 496 431 376 ... ... ... SCHED.SQ. FT. MAX LRC = CIRCUIT FEET ADDED: 1540' 17 1,000 75 AMPS THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) MATCHLINE A-A (SEE LEFT) MATCHLINE A-A (SEE RIGHT) Developer Note: The following Fault Current information MUST BE conveyed to the builder of the units: All units may require upgraded house electrical equipment as the fault current at the meter base may exceed 10,000 amps. FAULT CURRENT TABLE 3Ø PM TRANSFORMERS (208Y/120V) 120V WINDINGS 208V WINDINGS LOCATION SIZE R/X MIN. %Z FAULT CURRENT MIN. %Z FAULT CURRENT V01 & V03 150kVA 0.2 --2.15 29,000 AMPS V02 225kVA 0.3 --2.10 39,700 AMPS DEVELOPER TO COORDINATE WITH PSE PROJECT MANGER & SERVICE PROVIDER PRIOR TO EXCAVATING WITHIN 3' OF LOCATE MARKS OF PSE ENERGIZED FACILITIES LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #G 12 + HP 1,000 800A ELEC 51KW + 18KW 75A 4.8 @ V03 0.9 @ V03 CUSTOMER OWNED AND INSTALLED SECONDARY WIRE TABLE BLDG.# OF METERS SOURCE # OF RUNS WIRE SIZE REMARKS A 13 V01 3 300KCMIL - B 13 V01 3 300KCMIL - C 25 V02 6 300KCMIL - D 13 V02 3 300KCMIL - E 13 V02 3 300KCMIL - F 13 V03 3 300KCMIL - G 13 V03 3 300KCMIL - H 8 V03 3 300KCMIL - ALL CUSTOMER-OWNED WIRE MUST BE INSTALLED ACCORDING TO THIS TABLE COMM. DEMAND: (EV CHARGER, LIGHTS) COMM. DEMAND: (EV CHARGER, LIGHTS) COMM. DEMAND: (EV CHARGER, LIGHTS) COMM. DEMAND: (EV CHARGER, LIGHTS) LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #F 12 + HP 900 800A ELEC 51KW + 18KW 75A 4.8 @ V03 0.9 @ V03 COMM. DEMAND: (EV CHARGER, LIGHTS) LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #H 7 + HP 1,000 800A ELEC 35KW + 19KW 75A 4.8 @ V03 0.8 @ V03 COMM. DEMAND: (EV CHARGER, LIGHTS, OFFICE, RECREATION) COMM. DEMAND: (EV CHARGER, LIGHTS) COMM. DEMAND: (EV CHARGER, LIGHTS) LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #A 12 + HP 900 800A ELEC 51KW + 18KW 75A 4.0 @ V01 0.9 @ V01 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #B 12 + HP 900 800A ELEC 51KW + 18KW 75A 4.0 @ V01 0.9 @ V01 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #C 24 + HP 900 2x800A ELEC 94KW + 29KW 75A 4.7@ V02 0.6 @ V02 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #D 12 + HP 900 800A ELEC 51KW + 18KW 75A 4.7 @ V02 0.6 @ V02 LRC: % V. Drop: % Flicker: Sq. Footage: Panel Size: Heat Type: Est. Demand: Units: BUILDING #E 12 + HP 900 800A ELEC 51KW + 18KW 75A 4.7 @ V02 0.6 @ V02 3.10.25 LO N G M I R E S T Y E L M A V E W #2A C S R C B A #2A C S R C B A 3 9 7 A C S R 3 9 7 A C S R AB C AB C 601 W A S H I N G T O N C T S W # 2 A C S R A 90' 85' 5 5 ' 80' 60' 5 0 ' 5 6 ' NEW RECLOSER SW#X94392 SOLID BLADE #6CU CB A #6CU #2 A C S R C C #6 C U C TE R R A G L E N S T S E LONGMIRE ST 50 ' 50 ' 6 0 ' 40' 45' SW#T94394 DU R A N T S T S #2ACSR CB A LONGMIRE ST #6C U C B A #2A C S R RE-FUSE @ 100T 15425 SW#X94393 D E - E N E R G I Z E D 1 0 0 T H A V E S E 50 ' 55' N.O. DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP J. CALLAHAN 206.503.1520 . A. DUNN .02.10.25 N/A .N/A S. LEWISON .02.10.25 REDT # ( RW-134414 )YELM TAHOMA TERRA APARTMENTS PH 2 3Ø PRIMARY U/G LINE EXTENSION - 8 M/F BLDGS, 103 UNITS 14730 TAHOMA BLVD SE (P#78640000010), YELM, WA 98597 PUGET SOUND ENERGY N/A N/A N/A 105104609 AS SHOWN 3 OF 4 THURSTON N/A N/A QSTHLE 24SW-T17N-R01E N/A N/A 1701E095 1702E116 1701E095 YEL-25 COMCAST TED AXTELL 253.878.2794 LUMEN DEWAYNE RICHERT 253.221.0133 RIGHT OF WAY LINDA OLSON 425.786.4806 . . . ... ... ... EX OVERHEAD CIRCUIT MAP 1702E116 SCALE: 6" = 1 MILE EX UNDERGROUND CIRCUIT MAP 1701E095 NOT TO SCALE THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) 1" = 50' SITE PLAN (2) 1" = 50' SITE PLAN (4) 1" = 50' SITE PLAN (3) Site: Grid #: Recloser Company ID#: Controller Company ID#: RECLOSER Action:Installed Removed Recloser Material ID#: Controller Material ID#: Recloser Type: Foreman to redline the following information G&W Viper 15.5kV w/ VS 9999668 9999667 X 559497-147251 P1A SITE 1 SITE SITE SPECIFIC NOTES AT P01 (559497-147251) 45' CLASS 1, 2005 -POLE TO BE REPLACED -REMOVE POLE AND ALL PSE EQUIPMENT AT NEW P1A -POLE TO BE SET 5' N OF EX P01 -INSTALL NEW 45' CLASS 1 POLE (PD451) 6010.1000 -INSTALL 11' DOUBLE WOOD DISTRIBUTION ARMS (ARD2S11) 6011.1010 -INSTALL 12kV 600A G&W VOLTAGE SENSOR INLINE RECLOSER W/CPT (REC15VGWTS) 6023.1021 -INSTALL SW#X94392 -INSTALL EX. GRID #559497-147251 AT P02 (559361-147132) 45' CLASS 1, 2005 POLE TO REMAIN -RE-FUSE @ 100T (3412700); TAP 3Ø -INSTALL SW#X94393 AT P03 (559368-147022) 45' CLASS 2, 2005 POLE TO REMAIN -REMOVE (3) 100T FUSES -INSTALL (3) SOLID BLADES (9995608) -INSTALL SW#T94394 SITE 2 SITE 3SITE 4 NEW @ P1A: %V DROP: 4.8 % FLICKER: 5.6 EXISTING @ P01: % V. DROP: 4.9 % FLICKER: 5.6 Other sites not shown due to OH nature of work. 3.10.25 F E E D YEL 25 NEW 1/O AL EKB109-AØ EKB110-BØ EKB111-CØ AØAEN979 BØAEN980 CØAEN981 AØAEN000 BØAEN001 CØAEN002 AØAFA000 BØAFA001 CØAFA002 NEW 1/O AL EKB100-AØ EKB101-BØ EKB102-CØ NEW 1/O AL EKB106-AØ EKB107-BØ EKB108-CØ NEW 1/O AL EKB103-AØ EKB104-BØ EKB105-CØ AØAEN991 AØAEN985 BØAEN986 CØAEN987 AØAEN982 BØAEN983 CØAEN984 AØAEN988 BØAEN989 CØAEN990 BØAEN997 BØEJL548 (3) 300KCMIL (3) 300KCMIL (3) 300KCMIL (6) 300KCMIL (3) 300KCMIL (3) 300KCMIL (3) 300KCMIL (3) 300KCMIL DEVELOPER RESPONSIBLE FOR CONDUIT/WIRE FROM VAULT TO METER LOCATION BLDG H 7 UNITS 1000 SQFT BLDG G 12 UNITS 1000 SQFT BLDG F 12 UNITS 900 SQFT BLDG E 12 UNITS 900 SQFT BLDG D 12 UNITS 900 SQFT BLDG C 24 UNITS 900 SQFT BLDG B 12 UNITS 900 SQFT BLDG A 12 UNITS 900 SQFT DESIGNED BY UTILITIES CONTACT PHONE# COUNTY 1/4 SEC U-MAP NO (POWER) OP MAP Emer Sect Gas Wk Ctr POWER WK CTR PLAT MAP JOINT FACILITIES ARRANGEMENTS DRAWN BY CHECKED BY APPROVED BY FOREMAN #1 FOREMAN #2 MAPPING INCIDENT MAOP Gas Order Elect Order SCALE PAGE ENGR - POWER ENGR - GAS FUNCTION PROJECT MGR PERMITREAL ESTATE/EASEMENT 2 1 REV# 3 DATE DESCRIPTIONBY CONTACT PHONE NO DATE OH CKT MAP CIRCUIT NOUG CKT MAP J. CALLAHAN 206.503.1520 . A. DUNN . 02.10.25 N/A .N/A S. LEWISON . 02.10.25 REDT # ( RW-134414 )YELM TAHOMA TERRA APARTMENTS PH 2 3Ø PRIMARY U/G LINE EXTENSION - 8 M/F BLDGS, 103 UNITS 14730 TAHOMA BLVD SE (P#78640000010), YELM, WA 98597 PUGET SOUND ENERGY N/A N/A N/A 105104609 N/A 4 OF 4 THURSTON N/A N/A QSTHLE 24SW-T17N-R01E N/A N/A 1701E095 1702E116 1701E095 YEL-25 COMCAST TED AXTELL 253.878.2794 LUMEN DEWAYNE RICHERT 253.221.0133 RIGHT OF WAY LINDA OLSON 425.786.4806 . . . ... ... ... NEW PRIMARY UNDERGROUND CIRCUIT ONE-LINE DIAGRAM NOT TO SCALE THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES CALL (800) 424-5555 2 BUSINESS DAYS BEFORE YOU DIG For contacts below dial 1-888-CALL PSE (225-5773) VAULT & EQUIPMENT TABLE SITE # GRID # VAULT SIZE & COVER TYPE & SIZE EQUIPMENT IN VAULT PRIMARY BUSHINGS TRANSFORMER ID NUMBERS (COMPANY ID) AS-BUILT INFORMATION LB DC FOREMAN: INCLUDE PHASE TAPPED V01 559398 146893 4'8"x4'8"x4' w/20"x44" Hole Matid: 7663900 Cover: 7655200 150KVA PM TRF 120/208 Matid: 6258100 3 - PM3P15S 6045.5000 3Ø CONNECTOR (7651002) MOUNTING KIT (7651008)X3 V02 559440 146897 4'8"x4'8"x4' w/20"x44" Hole Matid: 7663900 Cover: 7655200 225KVA PM TRF 120/208 Matid: 6258150 3 - PM3P15S 6045.5000 3Ø CONNECTORS (7651002), (7651000) X2 MOUNTING (7651008)x5 V03 559496 146889 4'8"x4'8"x4' w/20"x44" Hole Matid: 7663900 Cover: 7655200 150KVA PM TRF 120/208 Matid: 6258100 3 - PM3P15S 6045.5000 3Ø CONNECTORS (7651002), (7651000) MOUNTING (7651008)x4 J01 559473 146906 4'8"x7'x5' w/2-3' Sq Doors Matid: 7663200 J-Box Below Grade w/4-Pos J-Bus x3 Matid: 7625900 12 -JBOX15L 6055.1030 3Ø ELB10J 6041.1000 Existing J02 559477 146894 4'8"x7'x5' w/2-3' Sq Doors Matid: Existing J-Box Below Grade w/4-Pos J-Bus x3 Matid: Existing 3 - ELB10J 6041.1000 TAP 3Ø PRIMARY CABLE & CONDUIT TABLE LOCATION CONDUIT CABLE ASBUILT INFORMATION - FOREMAN COMPLETE FROM TO SIZE (IN)QTY. DESIGN LENGTH (FT) BENDS PULL (LBS) PULL REV (LBS) CABLE SIZE DESIGN LENGTH (FT) PHASE - ID TAG RECORD RECORD PHASE TAPPED & ACTUAL FOOTAGE INSTALLED LUBRICANT (Gal.) 90° 45°22° 11°A B C MANUFACTURER COMPOUND YEAR NOTES CONDUIT CABLE EST. ACTUAL J02 J01 4 1 90 - 1 - -176 174 3Ø 1/0 AL JKT 100 EKB100 EKB101 EKB102 -0.7 J01 V01 4 1 785 - - - -466 466 3Ø 1/0 AL JKT 795 EKB103 EKB104 EKB105 -5.5 J01 V02 4 1 345 - - - -265 265 3Ø 1/0 AL JKT 355 EKB106 EKB107 EKB108 -2.5 J01 V03 4 1 325 1 3 - -475 466 3Ø 1/0 AL JKT 335 EKB109 EKB110 EKB111 -2.3 4" PVC (FT) & BENDS =1545 1 4 0 0 3Ø 1/0 AL JKT TOTAL (FT) =1585 TTL (Gal.)11.0 NOT TO SCALE NEW CONDUIT DIAGRAM CUST. OWNED PRIMARY 4" CONDUIT LEGEND 3.10.25