Loading...
25-052-A Customer Drawings 2025-03-033/3/2025 CHK'D: REV 1: DRAWN: REV 2: REV 4: REV 3: EEC JOB NO.: SHEET NO.: SHOP DWG NO.: PROJ. NO.: THIS CERTIFICATION OF DRAWINGS IS FOR THE ONE BUILDING ONLY AT THE SITE LISTED ABOVE. IT IS VALID ONLY IF THE MATERIALS SHOWN ON THESE DRAWINGS ARE FURNISHED BY RCP SHELTERS, INC. AND ONLY IF MATERIALS ARE PAID FOR IN FULL. IF MODIFICATION IS MADE WITHOUT EXPRESSED WRITTEN CONSENT OF RCP SHELTERS, INC., OR IF PAYMENT IS NOT MADE IN FULL, THEN CERTIFICATION BECOMES NULL & VOID. DESIGN CERTIFICATION FOR: BUILDING SIZE: BUILDING LOCATION: THIS PRINT IS THE PROPERTY OF RCP SHELTERS AND IS NOT TO BE USED, COPIED, OR REPRODUCED WITHOUT THEIR EXPRESSED WRITTEN PERMISSION. RC P S H E L T E R S , I N C . 21 0 0 S E R A Y S W A Y , S T U A R T , F L 3 4 9 9 4 E- m a i l - i n f o @ r c p s h e l t e r s . c o m Ph o n e 7 7 2 - 2 8 8 - 3 6 0 0 SH E L T E R S P A V I L I O N S CO N C E S S I O N S KI O S K S FA B R I C S H A D E RE S T R O O M S BA N D S H E L L S MI N I - S H E L T E R S DU G O U T S FA B R I C S A I L ww w . r c p s h e l t e r s . c o m Fa x 7 7 2 - 2 8 8 - 0 2 0 7 PO B O X 2 5 , S T U A R T , F L 3 4 9 9 5 - 0 0 2 5 CONTRACT NOTE: Reference accepted proposal and/or executed contract for identification of items furnished. Any item not specifically included shall be provided by owner, installer or others. Some items are specifically noted as N.I.C. (not in contract). LAMINATED WOOD SPECIFICATIONS: SPECIES -------------------------------- SOUTHERN PINE LAMINATION THICKNESS --------- 1" NOMINAL @ B-1, 2" NOMINAL @ C-1 STRESS COMBINATION ----------- SEE MEMBER DETAILS ADHESIVE ------------------------------ TWO PART STRUCTURAL URETHANE HYBRID (LAMINATOR OPTION: RESORCINOL) APPEARANCE GRADE ------------- ARCHITECTURAL FINISH ---------------------------------- SEAL & STAIN PROTECTION ------------------------ INDIVIDUAL WRAP PRESERVATIVE TREATMENT -- CCA 0.4 PCF (MIN) RETENTION @ COLUMNS, TREATED PRIOR TO GLUING HARDWARE -------------------------- PER DETAILS & LIST SOLID TIMBER SPECIFICATIONS 2 x 4 Nailer ----------- #1 SYP, S4S, KD, Seal & Stain 2 x 6 Fascia ---------- #1 AYC, S4S, KD, Seal & Stain 2 x 8 Roof Deck ----- #1 SYP, T&G, S/L, CM, EV1S, KD, Seal & Stain Deck furnished in specified lengths (S/L), not precision end trimmed (PET), field cutting required. ROOF UNDERLAYMENT SPECIFICATIONS: TWO LAYERS OF SYNTHETIC UNDERLAYMENT. SYNTHETIC UNDERLAYMENT TO CONFORM TO ASTM D226 TYPE II OR ASTM D4869 TYPE IV. ATTACH UNDERLAYMENT PER MANUFACTURER'S RECOMMENDATIONS OR BUILDING CODE REQUIREMENTS, WHICHEVER IS MORE STRINGENT. WOOD SHOP NOTES: 1. Materials, Manufacture and Quality Control of glulam shall be in conformance with, "American National Standard for Wood Products-Structural Glued Laminated Timber ANSI A190.1-2017". 2. Members shall be marked (in an unseen location) with an AITC or APA/EWS Quality Mark and, in addition, an AITC or APA/EWS Certificate of Conformance shall be provided to indicate conformance with "ANSI A190.1-2017". 3. ▲ denotes edges to be chamfered for welds. STEEL & HARDWARE SHOP NOTES: 1. All steel plate to be ASTM A572 Grade 50. 2. All welding is to be done in accordance with latest AWS standards. If welds are not specified, all welds are to develop full strength of all component parts. 3. All fabricated steel to be powder coated; color selected by owner. 4. Hardware (bolts, nuts, washers, etc.) to be hot-dipped galvanized (HDG). Shop to verify hole tolerances and tolerances of threaded parts for compatibility of the galvanized parts only. ERECTION NOTES: All wood members must be properly braced until the complete structural system has been constructed. Correction of minor misfits and a reasonable amount of reaming or alignment with drift pins will be considered a legitimate expense of erection. In the event of error, defect in materials, and/or workmanship of shop work which prevents proper assembling and fitting up of parts by the moderate use of drift pins, or reaming, immediately report to the seller and obtain seller's approval of the method of correction. Predrill wood for screws and nails if necessary to avoid splitting. NOTE: This building has been designed as a free standing, open structure. If walls are to be added, or if the building is to adjoin another structure, or if other modifications are to be made, the structure must be re-engineered prior to these modifications (by others). 20 ' - 0 " O U T / O U T O F F A S C I A ROOF FRAMING PLAN SCALE: 1/2" = 1'-0" 1'-3" B-1 B-1 B-1 S- 1 S- 1 S- 1 S- 1 S- 1 S- 1 3/12 3/12 DE C K DE C K 12'-0" OUT/OUT OF ROOF LAMINATED MEMBERS ARE WRAPPED FOR PROTECTION IN TRANSIT. THE ERECTOR IS RESPONSIBLE FOR PROTECTION OF MATERIALS AT ALL TIMES AFTER ARRIVAL AT DESTINATION. IF STORED TEMPORARILY, MEMBERS SHOULD BE PLACED ON BLOCKS & LEVELED, WELL OFF OF THE GROUND & SEPARATED WITH WOOD STRIPS SO THAT AIR CAN CIRCULATE AROUND EACH MEMBER. COVER THE TOP & SIDES WITH MOISTURE RESISTANT PAPER OR OPAQUE PLASTIC. USE NON-MARRING SLINGS WHEN HANDLING. ROOF COVERING SHOULD BE APPLIED SOON AFTER ERECTION. PROTECTIVE WRAPPING SHOULD REMAIN ON THE MEMBERS UNTIL DECK HAS BEEN INSTALLED & ROOFING APPLIED. HOWEVER, IF THE PAPER HAS BEEN TORN OR PARTIALLY REMOVED DURING STORAGE OR ERECTION, IT SHOULD BE REPLACED OR ENTIRELY REMOVED TO PREVENT DISCOLORATION OF LAM MEMBERS BY SUNLIGHT. LAMINATED MEMBERS RECEIVE ONE FACTORY APPLIED COAT OF CLEAR WOOD SEALER. (FACTORY STAIN IS OPTIONAL AT EXTRA COST). IF THEY SHOULD BECOME WET DURING SHIPMENT OR INSTALLATION, OR IF THEY ARE CLEANED IN ANY WAY, THESE LAMINATED MEMBERS SHOULD BE UNIFORMLY RESEALED BEFORE ADDITIONAL STAINING OR FINISHING IS DONE IN THE FIELD. DECKING WILL BE DELIVERED IN BANDED BUNDLES, WEIGHING APPROXIMATELY TWO TONS. BUNDLES SHOULD REMAIN BANDED UNTIL DECK IS TO BE INSTALLED. A FORKLIFT OR SMALL CRANE WILL BE REQUIRED FOR UNLOADING. BE SURE TO USE NON-MARRING SLINGS. IT IS THE ERECTORS RESPONSIBILITY TO TALLY THE DECKING UPON ARRIVAL. NOTIFY "MANUFACTURER" AT ONCE OF ANY SHORTAGES. UNLOADING, HANDLING, & STORAGE OF GLU-LAM & DECKING 2' - 0 " DESIGN CRITERIA: WA State Building Code w/ 2021 IBC Type of Construction: Type V-B Occupancy Classification: Assembly A-3 Building Risk Category II Mean Roof Height = 9’-0” Building Area = 240 ft2 Building Volume = 2,160 ft3 No. of Occupants = 16 (15 ft2 per person) ROOF DL Metal Roofing 0.9 psf Underlayment 0.2 psf 2” Nom. T&G Deck 4.4 psf Misc.1.5 psf Total = 7.0 psf + weight of framing FLOOR LL L = 100 psf ROOF LL Lr = 20 psf ROOF SL Pg = 20 psf (Ground Snow) Pf = 0.7*Pg*Ce*Ct*IS Ce = 1.0, Ct = 1.2, IS = 1.0 Pf = 16.8 psf Ps = Pf *Cs 3:12 pitch: Cs = 1.0, Ps = 16.8 psf + unbalanced Pm = 25.0 psf on roof WIND LOAD Vult = 97 mph, Vasd = 75 mph Exposure 'C', Open Building w/ GCpi = 0 Component & Cladding Ultimate Wind Pressures: Pressure = 32.5 psf, Suction = -35.2 psf SEISMIC IE = 1.0 SS = 1.287, S1 = 0.464 Site Class D (assumed) SDS = 1.030, SD1 = 0.568 Seismic Design Category D Equivalent Lateral Force Procedure Cantilevered Column Systems - Timber Frames R = 1.5, CS = 0.687, ρ = 1.3, V = 1,600# CLEAR PROTECTIVE FILM MUST BE REMOVED FROM ALL METAL PRIOR TO INSTALLATION. METAL ROOFING SHOULD BE STORED INDOORS OR WHEN STORED OUTSIDE IT SHOULD BE STORED UP ON BLOCKS WITH FINISHED FACE UP AND SLOPED TO DRAIN. DURING INSTALLATION, ALL METAL SHAVINGS MUST BE REMOVED IMMEDIATELY TO AVOID RUSTING OF PANELS. METAL ROOFING NOTES: 3 A 1'-3"9'-6" CTR./CTR. OF COLUMNS 2' - 0 " 8' - 0 " 8' - 0 " OF 25-052-A 15471 R SH E L M M E A D O W S YE L M , W A 25-052-A LW - G 1 2 2 0 - 0 3 TJE 3-3-25 1 5 12' x 20' YELM, WA 3/3/2025 CHK'D: REV 1: DRAWN: REV 2: REV 4: REV 3: EEC JOB NO.: SHEET NO.: SHOP DWG NO.: PROJ. NO.: THIS PRINT IS THE PROPERTY OF RCP SHELTERS AND IS NOT TO BE USED, COPIED, OR REPRODUCED WITHOUT THEIR EXPRESSED WRITTEN PERMISSION. RC P S H E L T E R S , I N C . 21 0 0 S E R A Y S W A Y , S T U A R T , F L 3 4 9 9 4 E- m a i l - i n f o @ r c p s h e l t e r s . c o m Ph o n e 7 7 2 - 2 8 8 - 3 6 0 0 SH E L T E R S P A V I L I O N S CO N C E S S I O N S KI O S K S FA B R I C S H A D E RE S T R O O M S BA N D S H E L L S MI N I - S H E L T E R S DU G O U T S FA B R I C S A I L ww w . r c p s h e l t e r s . c o m Fa x 7 7 2 - 2 8 8 - 0 2 0 7 PO B O X 2 5 , S T U A R T , F L 3 4 9 9 5 - 0 0 2 5 9'-6" CTR./CTR. OF PIERS1'-8" 20 ' - 0 " O U T / O U T O F S L A B 2' - 0 " 1'-8" FOUNDATION PLAN SCALE: 1/2" = 1'-0" C- 1 C- 1 C-1 C- 1 C-1 C-1 8' - 0 " CT R . / C T R . O F P I E R S 8' - 0 " CT R . / C T R . O F P I E R S 12'-10" OUT/OUT OF SLAB 2' - 0 " SEE COLUMN FOUNDATION DETAIL ON THIS SHEET. ALL DIMENSIONS SHOWN SPRINGING OFF OF THE SLAB EDGE ARE MINIMUMS. OWNER TO DETERMINE SLAB SIZE PRIOR TO CONSTRUCTION. CONCRETE NOTES: 1. Remove all organic material and topsoil from slab area. Verify suitability of subgrade. Footings are to bear on undisturbed, natural soil or engineered fill. Both are to be compacted to 95% Proctor density. 2. Prepare slab with min. 8" compacted sand, gravel, or crushed rock. 3. Concrete slab to be 4" thick. Reinforce slab with 6x6-w1.4xw1.4 welded wire fabric at mid-depth. Lap splices 8". Alt.: Fiber mesh admixture (min. 1.5#/c.y., fibrillated polypropylene). 4. Edge of slab to be thickened to min. 8" deep x 8" wide reinforced with 2-#4 continuous rebars. Lap splices min. 24". 5. In locations subject to frost, install isolation joint, max. 1/8" wide, around column piers using diamond or circular layout. Wire mesh shall be interrupted at isolation joints. 6. Install crack control joints (3/16" wide x 1" deep) at 8' to 12' o.c. 7. Concrete slab shall be sloped for drainage from center to edge and away from columns. Surface is to be lightly broomed or have a wood troweled finish. 8. Concrete slab, foundation, re-bar, wire mesh, leveling nuts, grout & anchor bolts (if required) are N.I.C. 9. All concrete reinforcing steel to be grade 60, deformed bars. 10.F'c of concrete to be 3000 psi @ 28 days for foundation. F'c of concrete to be 3500 psi @ 28 days for slab, air-entrained (F'c of concrete = 2500 psi for design). 11.All concrete work to be in accordance w/ latest ACI code. 12.Assumed allowable soil bearing pressures: 1500 psf vertical bearing, 100 pcf passive lateral bearing. It is the Owner's responsibility to verify that the allowable soil bearing values at the site meet or exceed these assumed values. If the actual values are lower than the assumed values, the foundations must be redesigned (N.I.C.). 13.Reinforcement shall be securely held in place while placing concrete. If required, additional bars, stirrups or chairs shall be provided to furnish support for bars. COLUMN FOOTING DETAIL FTG. & COL. FT G . , C O L . & B E A M A B O V E PLAN #3 HORIZONTAL TIES @ 10" O.C. MAX. (8) - #5 VERTICAL REBAR 2'-0"Ø 3' - 1 0 " 2" C L E A R 0'-0" TOP OF SLAB AT COL. C.L. 4" 4" MA X . 3" C L E A R 3" CLEAR COLUMN BASE REACTIONS: VDL+SL = 1,650# V0.6*DL+0.6*WL = -150# HDL+0.7*E = 290# MO.T. DL+0.7E = 2,150#-ft 51 2" 5" 3' - 0 " C O L U M N E M B E D M E N T (6)-0.20"Ø x 8" ANNULAR RING NAILS w/ 4" PENETRATION 4" 2" 2" 2" 2" 2" OF 25-052-A 15471 R SH E L M M E A D O W S YE L M , W A 25-052-A LW - G 1 2 2 0 - 0 3 TJE 3-3-25 2 5 THICKENED SLAB EDGE DETAIL SEE THICKENED SLAB EDGE DETAIL ON THIS SHEET 8" 8"4" 4" 5" T Y P . HORIZONTAL TIE ENDS SHALL OVERLAP TO THE ADJANCENT VERTICAL BAR AND SHALL TERMINATE WITH A STANDARD 90° HOOK. OVERLAPS AT ENDS OF ADJACENT TIES SHALL BE STAGGERED AROUND THE PERIMETER ENCLOSING THE VERTCAL BARS. 3/3/2025 CHK'D: REV 1: DRAWN: REV 2: REV 4: REV 3: EEC JOB NO.: SHEET NO.: SHOP DWG NO.: PROJ. NO.: THIS PRINT IS THE PROPERTY OF RCP SHELTERS AND IS NOT TO BE USED, COPIED, OR REPRODUCED WITHOUT THEIR EXPRESSED WRITTEN PERMISSION. RC P S H E L T E R S , I N C . 21 0 0 S E R A Y S W A Y , S T U A R T , F L 3 4 9 9 4 E- m a i l - i n f o @ r c p s h e l t e r s . c o m Ph o n e 7 7 2 - 2 8 8 - 3 6 0 0 SH E L T E R S P A V I L I O N S CO N C E S S I O N S KI O S K S FA B R I C S H A D E RE S T R O O M S BA N D S H E L L S MI N I - S H E L T E R S DU G O U T S FA B R I C S A I L ww w . r c p s h e l t e r s . c o m Fa x 7 7 2 - 2 8 8 - 0 2 0 7 PO B O X 2 5 , S T U A R T , F L 3 4 9 9 5 - 0 0 2 5 4'-61 4" 7 ' - 0 " R A D . 338 " 5 1/2" FLAT 478" 9" 12'-0" OUT/OUT OF FASCIA 12 3 14.0362 4 ° 6'-0" S-1 51 2" 7' - 8 9 16 " 8' - 0 " C. BEAM B-1 (CB-12-03-059-A) 5" WIDTH 3-REQ'D. SOUTHERN PINE 24F-V3 BUILDING AND BEAM A 3 SECTION SCALE: 1"=1'-0" TOP OF CONCRETE SLAB SEE COLUMN FOOTING DETAIL FOR ADDITIONAL INFORMATION. 1' - 6 " 1'-01 4" FASCIA 3 4" x 26ga. x 50ksi MAX-RIB PREFINISHED ROOF PANELS (3'-0" COVERAGE PER SHEET) SEE DECK DETAILS FOR ATTACHMENT. OVER ROOF UNDERLAYMENT OVER 2x8 DECKING. x -req'd.COLUMN C-1 5" 5 1/2"6 TREATED 5"51 2" S-1 11 ' - 0 " CONN S-1 6-req'd. -2 MK-1 PLATE -32 4 GA. x 2 1/2" ANNULAR RING NAIL, GALV. ERECTOR NOTE: DRILL 5/32"Ø PILOT HOLES IN WOOD MEMBERS FOR NAILS. (SP000005x08A00.2500) 51 2" 7 8"7 8" 5" 212" 1" #50(1:12) FINISH 4 SIDES OF 25-052-A 15471 R SH E L M M E A D O W S YE L M , W A 25-052-A LW - G 1 2 2 0 - 0 3 TJE 3-3-25 3 5 3/3/2025 CHK'D: REV 1: DRAWN: REV 2: REV 4: REV 3: EEC JOB NO.: SHEET NO.: SHOP DWG NO.: PROJ. NO.: THIS PRINT IS THE PROPERTY OF RCP SHELTERS AND IS NOT TO BE USED, COPIED, OR REPRODUCED WITHOUT THEIR EXPRESSED WRITTEN PERMISSION. RC P S H E L T E R S , I N C . 21 0 0 S E R A Y S W A Y , S T U A R T , F L 3 4 9 9 4 E- m a i l - i n f o @ r c p s h e l t e r s . c o m Ph o n e 7 7 2 - 2 8 8 - 3 6 0 0 SH E L T E R S P A V I L I O N S CO N C E S S I O N S KI O S K S FA B R I C S H A D E RE S T R O O M S BA N D S H E L L S MI N I - S H E L T E R S DU G O U T S FA B R I C S A I L ww w . r c p s h e l t e r s . c o m Fa x 7 7 2 - 2 8 8 - 0 2 0 7 PO B O X 2 5 , S T U A R T , F L 3 4 9 9 5 - 0 0 2 5 12 3 14.0362 4 ° SIDE ELEVATIONEND ELEVATION SCALE: 1/2" = 1'-0"SCALE: 1/2" = 1'-0" DECK PLAN AT CORNERS BB CC 1. START LAYING DECK AT EAVE W/ TONGUES UP. 2. DRIVE COURSES TIGHT W/ BLOCKING. 3. TOE NAIL & FACE NAIL AT EACH SUPPORT (BEAMS) USING 16d COMMON NAILS. 4. SNAP CHALK LINE AT BUILDING RAKE & CUT DECKING STRAIGHT AND SQUARE. 5. DECKING IS FURNISHED IN SPECIFIED LENGTHS, 10'/10' TYPICAL DECK LAY-UP FASCIA NOTES: 1. ALL FASCIA CORNERS AND SPLICES ARE TO BE MITERED. 2. SEE DETAILS A & B FOR SPLICE DETAILS. 3. ATTACH FASCIA WITH 10d HDG CASING NAILS: a. TO 2x4 NAILER - 24" O.C. b. TO BEAM ENDS - 3 NAILS PER FASCIA c. TO ENDS OF ROOF DECKING - 1 NAIL PER DECK BOARD d. AT CORNERS - 2 NAILS EACH DIRECTION e. OTHER LOCATIONS - 24" O.C. TO ROOF DECKING 2 x 4 NAILER A. MITER ALL SPLICES B. NAIL SPLICES TOGETHER WITH (2) 10d HDG CASING NAILS, DRIVE NAILS AT AN ANGLE TO AVOID PUNCHING THRU FASCIA. AA AASECTION BBSECTION NAILER (2)-16d SINKERS PER DECK BOARD CCSECTION DETAIL B FASCIA DECKING DETAIL A NAILER DECKING FASCIA SPLICE NAILER SPLICE FASCIA SPLICE FASCIA ONLY AT BEAM ENDS. PREDRILL IF NECESSARY TO AVOID SPLITTING. FASCIA FASCIA WOOD DECK WOOD DECK METAL DECK NOT SHOWN METAL DECK NOT SHOWN 1'-101 2" (FIELD TRIM DECK) B- 1 6 3 4 " 1 71 6 " 2' - 0 " M I N . FASCIA LAY-UP AT EAVE 12'/12'. AT RAKE 8'. OF 25-052-A 15471 R SH E L M M E A D O W S YE L M , W A 25-052-A LW - G 1 2 2 0 - 0 3 TJE 3-3-25 4 5 3/3/2025 CHK'D: REV 1: DRAWN: REV 2: REV 4: REV 3: EEC JOB NO.: SHEET NO.: SHOP DWG NO.: PROJ. NO.: THIS PRINT IS THE PROPERTY OF RCP SHELTERS AND IS NOT TO BE USED, COPIED, OR REPRODUCED WITHOUT THEIR EXPRESSED WRITTEN PERMISSION. RC P S H E L T E R S , I N C . 21 0 0 S E R A Y S W A Y , S T U A R T , F L 3 4 9 9 4 E- m a i l - i n f o @ r c p s h e l t e r s . c o m Ph o n e 7 7 2 - 2 8 8 - 3 6 0 0 SH E L T E R S P A V I L I O N S CO N C E S S I O N S KI O S K S FA B R I C S H A D E RE S T R O O M S BA N D S H E L L S MI N I - S H E L T E R S DU G O U T S FA B R I C S A I L ww w . r c p s h e l t e r s . c o m Fa x 7 7 2 - 2 8 8 - 0 2 0 7 PO B O X 2 5 , S T U A R T , F L 3 4 9 9 5 - 0 0 2 5 THE ACTUAL ROOF PITCH MAY VARY FROM THESE GENERAL DETAILS. SECTION THRU ROOFING PANEL @ RAKE DECK DETAIL @ RIDGE RAKE TRIM ROOF DECK 36" COVERAGE ROOF DECK 9" RIDGE CAP 22 LN. FT. REQUIRED MAX-RIB PREFINISHED ROOF PANELS TAPE SEALANT MAX-RIB PREFINISHED ROOF PANELS OVER ROOF UNDERLAYMENT. FASCIA NAILER EAVE DETAIL OUTSIDE CLOSURE WITH TAPE SEALANT TOP & BOTTOM. ROOF UNDERLAYMENT INSTALLATION: FASTEN RIDGE CAP TO EACH ROOFING PANEL AT HIGH RIB. (1) LAP SCREW PER RIB, PER SIDE. ROOF RIDGE CAPDECK SCREWS, 1 EACH SIDE OF MAJOR RIBS. DECK SCREWS @ 12" O.C. DECK SCREWS @ 12" O.C. SELF-DRILLING SCREW SPECIFICATIONS: DECK SCREW = 9-15x1 WOODGRIP HWH SHARP POINT LAP SCREW = 1/4-14x7/8 IMPAX LAP, 5/16" HEX HEAD ROOF DECK (METAL DECK ATTACHMENT ALONG RIDGE IS SAME AS AT THIS SECTION) SECTION THRU ROOFING PANEL @ EAVE 36" COVERAGE SECTION THRU ROOFING PANEL @ INTERIOR 36" COVERAGE LAP SCREWS @ 20" O.C MAXIMUM. MASTIC TAPE BETWEEN PANELS. MAX-RIB PREFINISHED ROOF PANELS OVER ROOF UNDERLAYMENT DECK SCREWS, 1 3/4" ON EACH SIDE OF MAJOR RIBS ROOF DECK ROOF DECK DECK SCREWS, 1 3/4" ON EACH SIDE OF RIBS @ SPLICES. 1 3/4" ON ONE SIDE OF INTERMEDIATE RIBS, LINES OF SCREWS TO BE 24" O.C. 13 4"13 4" DECK SCREW DECK SCREWS @ 12" O.C. EAVE TRIM MAX-RIB PREFINISHED ROOF PANELS 1" ROOF UNDERLAYMENT INSIDE CLOSURE WITH TAPE SEALANT TOP & BOTTOM. FASCIA ROO F D E C K MAX-RIB PREFINISHED ROOF PANELS OVER ROOF UNDERLAYMENT EAVE TRIM 44 LN. FT. REQUIRED RAKE TRIM 32 LN. FT. REQUIRED 3" 312" 1 2" 414" 90 ° 90 ° 1 2 " 3 4" 31 2" 1" 28 . 0 7 2 5 ° 6' - 3 3 16 " D E C K L E N G T H 20'-0" TRUE PLAN AT ROOF PLANE 2-REQ'D SCALE: 1/2" = 1'-0" CLEAR PROTECTIVE FILM MUST BE REMOVED FROM ALL METAL PRIOR TO INSTALLATION. METAL ROOFING SHOULD BE STORED INDOORS OR WHEN STORED OUTSIDE IT SHOULD BE STORED UP ON BLOCKS WITH FINISHED FACE UP AND SLOPED TO DRAIN. DURING INSTALLATION, ALL METAL SHAVINGS MUST BE REMOVED IMMEDIATELY TO AVOID RUSTING OF PANELS. METAL ROOFING NOTES: OF 25-052-A 15471 R SH E L M M E A D O W S YE L M , W A 25-052-A LW - G 1 2 2 0 - 0 3 TJE 3-3-25 5 5