Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
25-005 YCS Transportation TI Equipment Submittal 3-21
KNIGHT FIRE PROTECTION, INC. 9702 LATHROP INDUSTRIAL DR. SW OLYMPIA, WA 98512-9188 (360) 786-8606 FAX 786-8722 LICENSE NO. KNIGHFP044LK Fire Sprinkler System Equipment Submittal Yelm Community Schools Transportation TI 202 NW Stevens Ave. Yelm, WA 98597 KFP Job #25-005 KFP Job #12-113 Page 1 of 8 JANUARY 2024 TFP151 Worldwide Contacts www.tyco-fire.com IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the QR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfp151 Series TY-B – 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprin- klers described herein are standard response, standard coverage, decora- tive 5 mm glass bulb-type spray sprin- klers. They are designed for use in light, ordinary, or extra-hazard commercial occupancies such as banks, hotels, shopping malls, factories, refineries, and chemical plants. The TY-B Recessed Pendent Sprinkler, where applicable, is intended for use in areas with a finished ceiling. It uses a two-piece Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) Recessed Escutcheon. The Recessed Escutcheon provides 1/2 in. (12,7 mm) of recessed adjust- ment or up to 3/4 in. (19,1 mm) of total adjustment from the flush pendent position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe drops to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond what would be obtained when exposed to corrosive atmo- spheres. Although corrosion-resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible corrosive atmospheres. Consequently, it is recommended that the end-user be consulted about the suitability of these coatings for any given corrosive envi- ronment. The effects of ambient tem- perature, concentration of chemicals, and gas/chemical velocity, should be considered as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. An intermediate level version of the Series TY-B Pendent Sprinkler can be obtained by utilizing the Series TY-B Pendent Sprinkler in combination with the Model S2 Shield. NOTICE The Series TY-B 2.8, 5.6, and 8.0 K-fac- tor, Upright, Pendent, and Recessed Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applicable standards of the National Fire Protection Association (NFPA), in addition to the standards of any other authorities having jurisdiction. Failure to do so may impair the perfor- mance of these devices. The owner is responsible for maintain- ing their fire protection system and devices in proper operating condi- tion. Contract the installing contrac- tor or product manufacturer with any questions. NFPA 13 prohibits installation of 1/2 in. NPT sprinklers with K-factors greater than 5.6 in new construction. They are intended for retrofit in existing sprinkler systems only. Sprinkler Identification Numbers (SIN) TY1151 ...Upright 2.8K, 1/2 in. NPT TY1251 ...Pendent 2.8K, 1/2 in. NPT TY3151 ...Upright 5.6K, 1/2 in. NPT TY3251 ...Pendent 5.6K, 1/2 in. NPT TY4151 ...Upright 8.0K, 3/4 in. NPT TY4251 ...Pendent 8.0K, 3/4 in. NPT TY4851 ...Upright 8.0K, 1/2 in. NPT TY4951 ...Pendent 8.0K, 1/2 in. NPT TFP151 Page 2 of 8 * ** ** * * PENDENTUPRIGHT CROSS SECTION 2-3/16" (55,6 mm) WRENCH FLATS Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. CEILING PLATE SEATING SURFACE 7/16" (11,1 mm) NOMINAL MAKE-IN 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) 2 4 5 6 7 3 1 1 2 Sealing Assembly Button Frame - - Bulb Bushing-7 3 - 4 - 6 - 1/2" NPT Deector Compression Screw 5 - *** ** * * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT 7/16" (11,1 mm) NOMINAL MAKE-IN ESCUTCHEON PLATE SEATING SURFACE STYLE 10 RECESSED ESCUTCHEON Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. 2-7/8" (73,0 mm) DIA.1/2" NPT 1 2 Button Frame - - Bulb4-6 -Deector 5 6 4 2 3 1 3 -5 - WRENCH FLATS 2-3/16" (55,6 mm) 2-3/16" (55,6 mm) 1-1/2" (38,1 mm) Sealing Assembly Compression Screw *** ** * * UPRIGHT PENDENT CROSS SECTIONRECESSED PENDENT ESCUTCHEON PLATE SEATING SURFACE Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. 1 2 Button Frame - - Bulb4-6 -Deector 3 -5 -Sealing Assembly Compression Screw 2-7/8" (73,0 mm) DIA.3/4" NPT 5 6 4 2 3 1 STYLE 40 RECESSED ESCUTCHEON WRENCH FLATS 1/2" (12,7 mm) NOMINAL MAKE-IN 2-1/4" (57,2 mm) 2-5/16" (58,7 mm) 1-9/16" (39,7 mm) FIGURE 1 SERIES TY-B UPRIGHT (TY1151) AND PENDENT (TY1251) SPRINKLERS 2.8 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE FIGURE 2 SERIES TY-B UPRIGHT (TY3151) AND PENDENT (TY3251) SPRINKLERS 5.6 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE FIGURE 3 SERIES TY-B UPRIGHT (TY4151) AND PENDENT (TY4251) SPRINKLERS 8.0 K-FACTOR, 3/4 IN. NPT, STANDARD RESPONSE TFP151 Page 3 of 8 Technical Data Approvals UL and C-UL Listed FM, LPCB, and VdS Approved EAC Approved Note: For complete approval infor- mation, including corrosion-resistant status, see Tables A, B, and C. Maximum Working Pressure See Table D Discharge Coefficient K=2.8 gpm/psi½ (40,3 Lpm/bar½) K=5.6 gpm/psi½ (80,6 Lpm/bar½) K=8.0 gpm/psi½ (115,2 Lpm/bar ½) Temperature Ratings See Tables A, B and C Finishes Sprinkler: See Table E Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Button . . . . . . . . . . . . . . . . . . . . . .Brass/Copper Sealing Assembly ..Beryllium Nickel w/TEFLON Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw . . . . . . . . . . . . . . . . .Bronze Deflector . . . . . . . . . . . . . . . . . . . . . . . . . Copper Bushing (K=2.8) . . . . . . . . . . . . . . . . . . . . .Bronze Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers are intended for fire protection systems designed in accordance with the stan- dard installation rules recognized by the applicable Listing or Approval agency, such as UL Listing based on the requirements of NFPA 13 and FM Approval based on the requirements of the FM Global Loss Prevention Data Sheets. Use only the Style 10 or 40 Recessed Escutcheon, as applicable, for recessed pendent installations. * ** ** * * PENDENTUPRIGHT CROSS SECTION 2-1/4" (57,2 mm) 1-9/16" (39,7 mm) 2-3/16" (55,6 mm) 1 2 Sealing Assembly Button Frame - - Bulb 3 - 4 - 6 - 1/2" NPT WRENCH FLATS Deector Compression Screw 5 - 5 6 4 2 3 1 Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. CEILING PLATE SEATING SURFACE 7/16" (11,1 mm) NOMINAL MAKE-IN 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SURFACE FACE OF SPRINKLER FITTING 5/8±1/4" (15,9±6,4 mm) MOUNTING PLATE 1/8" (3,2 mm) SERIES TY-BCLOSURE 3/4" (19,1 mm) 1-1/4" (31,8 mm) 1/4" (6,4 mm) 3/4" (19,1 mm) 2-7/8" DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) MOUNTING SURFACE CLOSURE FACE OF SPRINKLER FITTING 5/8±1/4" (15,9±6,4 mm) MOUNTING PLATE 1-5/16" (33,3 mm) 13/16" (20,6 mm) 1/8" (3,2 mm) 3/4" (19,1 mm) 1/4" (6,4 mm) SERIES TY-B FIGURE 4 SERIES TY-B UPRIGHT (TY4851) AND PENDENT (TY4951) SPRINKLERS 8.0 K-FACTOR, 1/2 IN. NPT, STANDARD RESPONSE FIGURE 5 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 IN. TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON 5.6 K-FACTOR, 1/2 IN. NPT FIGURE 6 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 IN. TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON 8.0 K-FACTOR, 3/4 IN. NPT TFP151 Page 4 of 8 Installation The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) to 3/32 in. (2,4 mm) for the 360°F (182°C) temperature ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N·m). Obtain a leak-tight 3/4 in. NPT sprinkler joint by applying a minimum to maximum torque of 10 to 20 lb-ft (13,4 to 26,8 N·m). Higher levels of torque may distort the sprinkler inlet and cause leakage or impairment of the sprinkler. Do not attempt to compensate for insufficient adjustment in the escutch- eon plate by under- or over-tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Series TY-B Upright and Pendent Sprinklers Installation The Series TY-B Upright and Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. Install pendent sprinklers in the pendent position. Install upright sprin- klers in the upright position. Step 2. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 3. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench, see Figure 7. For wax-coated sprinklers, use an 8 or 10 in. adjustable wrench. With reference to Figure 1 to 4, apply the W-Type 6 Recessed Sprinkler Wrench or an adjustable wrench, as applicable, to the sprinkler wrench flats. Wax Coated Sprinklers When installing wax-coated sprinklers with an adjustable wrench, take care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corrosive environment: • Open the jaws of the wrench suffi- ciently wide to pass over the wrench flats without damaging the wax coating. • Before wrench tightening the sprin- kler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. • After wrench tightening the sprin- kler, loosen the wrench jaws before removing the wrench. After Installation After installation, complete the following: • Inspect the sprinkler wrench flats and frame arms and retouch (repair) the wax coating whenever the coat- ing has been damaged and bare metal is exposed. • Retouch the wax coating on the wrench flats by gently applying a heated 1/8 in. diameter steel rod to the damaged areas of wax, to smooth it back over areas where bare metal is exposed. NOTICE Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point it can begin to melt the wax, and appropriate precautions need to be taken when handling the heated rod in order to prevent the installer from being burned. Series TY-B Recessed Pendent Sprinklers The Series TY-B Recessed Pendent Sprinklers must be installed in accor- dance with the following instructions: Step 1. After installing the Style 10 or 40 Mounting Plate, as applicable, over the sprinkler threads and with pipe thread sealant applied to the pipe threads, hand-tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench, see Figure 8. With reference to Figure 3 or 4, apply the W-Type 7 Recessed Sprinkler wrench to the sprinkler wrench flats. Step 3. After the ceiling is installed or the finish coat is applied, slide on the Style 10 or 40 Closure over the Series TY-B Recessed Pendent Sprinkler and push the Closure over the Mount- ing Plate until its flange contacts the ceiling. Care and Maintenance The TYCO Series TY-B 2.8, 5.6, and 8.0 K-factor, Upright, Pendent, and Recessed Pendent Sprinklers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS (END "B" USED FOR 3/4" NPT MODELS) FIGURE 7 W-TYPE 6 SPRINKLER WRENCH FIGURE 8 W-TYPE 7 RECESSED SPRINKLER WRENCH TFP151 Page 5 of 8 K-Factor Sprinkler Type Temperature Rating Bulb Liquid Color Sprinkler Finish4 Natural Brass Chrome Plated Polyesterc Lead Coated Wax Coated Wax-Over-Lead Coated 2.8 1/2 in. NPT Upright (TY1151) and Pendent (TY1251) Figure 1 135°F (57°C)Orange 1, 2, 3 N/Ad 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve 1, 2 NOTES 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) 3. Approved by FM Global (FM Approvals) 4. Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers; Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable b. 150°F (66°C) maximum ceiling temperature c. Frame and deflector only d. Not Applicable (N/A) K-Factor Sprinkler Type Temperature Rating Bulb Liquid Color Sprinkler Finish5 Natural Brass Chrome Plated Polyesterc Lead Coated Wax Coated Wax-Over-Lead Coated 5.6 1/2 in. NPT Upright (TY3151) Figure 2 135°F (57°C)Orange 1, 2, 3, 4 N/Ad 1, 2, 3, 4 1, 2, 3, 4 1, 2, 3, 4 N/Ad 155°F (68°C)Red 1, 2, 3, 4 1, 2, 3, 4175°F (79°C)Yellow N/Ad 200°F (93°C)Green 1, 2, 3, 4286°F (141°C)Blue 1b, 2b, 3b, 4b 1b, 2b, 3b, 4b 360°F (182°C)Mauve N/Ad Pendent (TY3251) Figure 2 135°F (57°C)Orange 1, 2, 3, 4 1, 2, 3, 4, 5 1, 2, 3, 4 N/Ad 155°F (68°C)Red 1, 2, 3, 4175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 1b, 2b, 3b, 4b 1b, 2b, 3b, 4b 360°F (182°C)Mauve N/Ad Recessed Pendent (TY3251)a Figure 5 135°F (57°C)Orange 1, 2, 3, 4 N/A d 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 1, 2, 4 NOTES 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) 3. Approved by FM Global (FM Approvals) 4. EAC Approved 5. Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers; Where Lead Coated, Wax Coated, and Wax-over- Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable b. 150°F (66°C) maximum ceiling temperature c. Frame and deflector only d. Not Applicable (N/A) TABLE A SERIES TY-B 2.8 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TABLE B SERIES TY-B 5.6 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 6 of 8 K-Factor Sprinkler Type Temperature Rating Bulb Liquid Color Sprinkler Finish9 Natural Brass Chrome Plated Polyesterc Lead Coated Wax Coated Wax-Over-Lead Coated 8.0 3/4 in. NPT Upright (TY4151) Figure 3 135°F (57°C)Orange 1, 2, 3, 4, 6, 7, 8 1, 2, 5, 8 1, 2, 3, 8 1, 2, 8155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 1b, 2b, 3b, 8b 1b, 2b, 3b, 8b 360°F (182°C)Mauve N/A d Pendent (TY4251) Figure 3 135°F (57°C)Orange 1, 2, 3, 4, 6, 7, 8 1, 2, 5, 8 1, 2, 3, 8 1, 2, 8155°F (68°C)Red 175°F (79°C)Yellow 1, 2, 4, 6, 7, 8 1, 2, 8 200°F (93°C)Green 1, 2, 3, 4, 6, 7, 8 1, 2, 3, 8 286°F (141°C)Blue 1b, 2b, 3b, 8b 1b, 2b, 3b, 8b 360°F (182°C)Mauve N/A d Recessed Pendent (TY4251)a Figure 6 135°F (57°C)Orange 1, 2, 3, 4, 8 N/Ad 155°F (68°C)Red 175°F (79°C)Yellow 1, 2, 4, 8 200°F (93°C)Green 1, 2, 3, 4, 8 286°F (141°C)Blue 1, 2, 8 8.0 1/2 in. NPT Upright (TY4851) ) Figure 4 135°F (57°C)Orange 1, 2, 3, 4, 6 1, 2, 3, 4, 6 1, 2, 3, 4, 6 N/Ad 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve N/A d Pendent (TY4951) Figure 4 135°F (57°C)Orange 1, 2, 3, 4, 6 N/Ad 155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 360°F (182°C)Mauve NOTES 1. Listed by Underwriters Laboratories, Inc. (UL) 2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) 3. Approved by FM Global (FM Approvals) 4. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/03) 5. Note not used 6. VdS Approved. (For details, contact Johnson Controls, Enschede, Netherlands, Tel. 31-53-428-4444 / Fax 31-53-428-3377) 7. Approved by the Loss Prevention Certification Board (LPCB Ref. No. 094a/05) 8. EAC Approved 9. Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion-Resistant Sprinklers; Where Lead Coated, Wax Coated, and Wax-over- Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as Corrosion-Resistant Sprinklers a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable b. 150°F (66°C) maximum ceiling temperature c. Frame and deflector only d. Not Applicable (N/A) TABLE C SERIES TY-B 8.0 K-FACTOR UPRIGHT AND PENDENT SPRINKLERS LABORATORY LISTINGS AND APPROVALS TFP151 Page 7 of 8 K-Factor Type Sprinkler Finish Natural Brass Chrome Plated Polyester1 Lead Coated Wax Coated Wax-Over-Lead Coated 2.8 1/2 in. NPT Upright (TY1151) and Pendent (TY1251) 175 psi (12,1 bar)N/A 3 5.6 1/2 in. NPT Upright (TY3151) and Pendent (TY3251) 250 psi (17,2 bar)2 or175 psi (12,1 bar)Recessed Pendent (TY3251) 8.0 3/4 in. NPT Upright (TY4151) and Pendent (TY4251) 175 psi (12,1 bar) Recessed Pendent (TY4251)175 psi (12,1 bar)N/A 3 8.0 1/2 in. NPT Upright (TY4851) and Pendent (TY4951)175 psi (12,1 bar) NOTES 1. Frame and deflector only 2. The maximum working pressure of 250 psi (17,2 bar) only applies to the Listing by Underwriters Laboratories, Inc. (UL) and the Listing by Underwriters Laboratories, Inc. for use in Canada (C-UL). 3. Not Applicable (N/A) P/N 57 – XXX – X – XXX TEMPERATURE RATING 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) 360 360°F (182°C) 000 OPEN3 SPRINKLER FINISH 1 NATURAL BRASS 3 PURE WHITE (RAL9010)1 POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 5 JET BLACK (RAL9005)2 POLYESTER 6 WAX COATED 286°F (141°C) MAX 7 LEAD COATED 8 WAX-OVER-LEAD 286°F (141°C) MAX4 9 CHROME PLATED5 SIN 530 2.8K UPRIGHT (1/2 in. NPT)TY1151 531 2.8K PENDENT (1/2 in. NPT)TY1251 570 5.6K UPRIGHT (1/2 in. NPT)TY3151 571 5.6K PENDENT (1/2 in. NPT)TY3251 590 8.0K UPRIGHT (3/4 in. NPT)TY4151 591 8.0K PENDENT (3/4 in. NPT)TY42516 560 8.0K UPRIGHT (1/2 in. NPT)TY4851 561 8.0K PENDENT (1/2 in. NPT)TY4951 NOTES 1. Eastern Hemisphere sales only 2. Available in only 8.0 K-factor, 155°F (68°C) or 200°F (93°C); requires lead time to manufacture 3. Available only for 8.0 K-factor TY4151 and TY4251 for use in deluge systems (“OPEN” indicates sprinkler assembly without glass bulb, button, and sealing assembly) 4. Wax-Over-Lead finish not available for TY3151 Upright or TY3251 Pendent 5.6K 1/2 in. NPT 135°F (57°C) 5. Chrome Plated finish not available for TY3151 Upright 5.6K 1/2 in. NPT 135°F (57°C) and 175°F (79°C) or for TY4851 Upright 8.0K 1/2 in. NPT 360°F (182°C) 6. TY4251 in 175°F (79°C) temperature rating not FM Approved, see Table C for all applicable Listings and Approvals TABLE D SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS MAXIMUM WORKING PRESSURE TABLE E SERIES TY-B UPRIGHT AND PENDENT SPRINKLERS PART NUMBER SELECTION TFP151 Page 8 of 8 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON is a trademark of The Chemours Company FC, LLC 1467 Elmwood Avenue, Cranston, RI 02910 | Telephone +1-401-781-8220 © 2024 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, strik- ing, wrench twist/slippage, or the like, must be replaced. Replace any sprin- kler that has a cracked bulb or that has lost liquid from its bulb. See the Instal- lation Section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associ- ation such as NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinkler are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (specify SIN), (specify K-factor), (specify Upright or Pendent) Sprinkler with (specify) temperature rating, (specify) finish or coating, P/N (See Table E) Recessed Escutcheon Specify: Style (10 or 40) Recessed Escutcheon with (specify*) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrenches Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench- damaged wax coating) Specify: (specify color, below) Color- coded Wax Sticks for retouching (specify temperature rating) tempera- ture-rated Series TY-B Sprinklers, P/N (specify) Black for 135°F (57°C) ......P/N 56-065-1-135 Red for 155°F (68°C) .......P/N 56-065-1-155 Yellow for 175°F (79°C) .....P/N 56-065-1-175 Blue for 200°F (93°C) and 286°F (141°C) .........P/N 56-065-1-286 Note: Each wax stick is suitable for retouching up to 25 sprinklers. The wax used for 286°F (141°C) sprinklers is the same as for 200°F (93°C) sprinklers. Therefore, the 286°F (141°C) sprinkler is limited to the same maximum ceiling temperature as the 200°F (93°C) sprinkler which is 150°F (66°C). Page 1 of 6 SEPTEMBER 2022 TFP161 Worldwide Contacts www.tyco-fire.com IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Scan the QR code or enter the URL in a web browser to access the most up-to-date electronic version of this document. Data rates may apply. docs.jci.com/tycofire/tfp161 Series TY-B – 5.6 K-factor Horizontal and Vertical Sidewall Sprinklers Standard Response, Standard Coverage to aesthetics or building construction considerations, where piping across the ceiling is not desirable. The recessed version of the Series TY-B Horizontal Sidewall Sprinkler is intended for use in areas with a fin- ished wall. It uses a two-piece Style 10 Recessed Escutcheon. The Recessed Escutcheon provides 1/2 in. (12,7 mm) of recessed adjustment or up to 3/4 in. (19,1 mm) of total adjustment from the flush sidewall position. The adjustment provided by the Recessed Escutcheon reduces the accuracy to which the fixed pipe nipples to the sprinklers must be cut. Corrosion-resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmo- spheres. Although corrosion resistant coated sprinklers have passed the standard corrosion tests of the appli- cable approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suit- ability of these coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. NOTICE The Series TY-B Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the stan- dards of any other authorities having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Sprinkler Identification Numbers TY3351. . . . . . . . Horizontal Sidewall TY3451. . . . . . . . . . .Vertical Sidewall Technical Data Approvals UL and C-UL Listed FM Approved LPCB Certified NYC Approved EAC Approved Note: For complete approval infor- mation, including corrosion-resistant status, see Table A. Maximum Working Pressure See Table B General Description The TYCO Series TY-B, 5.6 K-factor, Horizontal and Vertical Sidewall Sprin- klers described in this technical data sheet are standard response, standard coverage decorative 5 mm glass bulb type spray sprinklers designed for use in light and ordinary hazard, commer- cial occupancies such as banks, hotels, and shopping malls. They are designed for installation along a wall or the side of a beam and just beneath a smooth ceiling. Sidewall sprinklers are commonly used instead of pendent or upright sprinklers due TFP161 Page 2 of 6 Discharge Coefficient K=5.6 gpm/psi1/2 (80,6 Lpm/bar1/2) Temperature Ratings See Table A Finishes Sprinkler: See Table C Recessed Escutcheon: Signal or Pure White, Grey Aluminum, Jet Black, Chrome Plated, or Natural Brass Physical Characteristics Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . .Bronze Button . . . . . . . . . . . . . . . . . . . . . .Brass/Copper Sealing Assembly ..Beryllium Nickel w/TEFLON Bulb . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Glass Compression Screw . . . . . . . . . . . . . . . . .Bronze HSW Deflector . . . . . . . . . . . . . . . . . . . . .Bronze VSW Deflector . . . . . . . . . . . . . . . . . . . . . Copper Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, allowing the sprinkler to activate and water to flow. Design Criteria The TYCO Series TY-B, 5.6 K-fac- tor, Horizontal and Vertical Side- wall Sprinklers are intended for fire protection systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (for example, UL Listing is based on the requirements of NFPA 13, and FM Approval is based on the requirements of the FM Loss Preven- tion Data Sheets). Only the Style 10 Recessed Escutcheon, as applicable, is to be used for recessed horizontal installations. Installation The TYCO Series TY-B, 5.6 K-factor, Horizontal and Vertical Sidewall Sprin- klers must be installed in accordance with this section. General Instructions Do not install any bulb type sprinkler if the bulb is cracked or there is a loss of liquid from the bulb. With the sprin- kler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1/16 in. (1,6 mm) for the 135°F (57°C) to 3/32 in. (2,4 mm) for the 360°F (182°C) tempera- ture ratings. A leak-tight 1/2 in. NPT sprinkler joint should be obtained by apply- ing a minimum-to-maximum torque of 7 to 14 lb-ft (9,5 to 19,0 N·m). Higher levels of torque may distort the sprin- kler inlet and cause leakage or impair- ment of the sprinkler. Do not attempt to make-up for insufficient adjustment in the escutcheon plate by under- or over- tightening the sprinkler. Readjust the position of the sprinkler fitting to suit. Horizontal Sidewall Sprinkler Installation The TYCO Series TY-B Recessed Hor- izontal Sidewall Sprinklers must be installed in accordance with the fol- lowing instructions. Install recessed horizontal sidewall sprinklers in the horizontal position with the centerline of waterway perpendicular to the back wall and parallel to the ceiling. The word “TOP” on the Deflector is to face towards the ceiling. Step A. After installing the Style 10 Mounting Plate over the sprinkler threads, hand-tighten the sprinkler into the sprinkler fitting. Step B. Tighten the sprinkler into the sprinkler fitting using only the W-Type 7 Recessed Sprinkler Wrench, see Figure 5. Apply the W-Type 7 Recessed Sprin- kler Wrench to the sprinkler wrench flats, see Figure 1. Step C. After the ceiling is installed or the finish coat is applied, slide on the Style 10 Closure over the Series TY-B Sprinkler and push the Closure over the Mounting Plate until its flange comes in contact with the ceiling. 1 2 3 4 6 5 ** * * ** * Button Frame Bulb Deector Temperature rating is indicated on Deector Sealing Assembly Compression Screw Pipe thread connections per ISO 7-1 can be provided on special request ESCUTCHEON PLATE SEATING SURFACE 1-13/16" (46,0 mm) CENTERLINE OF SPRINKLER WATERWAY 2-7/8" DIA. (73,0 mm) STYLE 10 RECESSED ESCUTCHEON 2-3/16" (55,6 mm) DEFLECTOR HAT 9/16" (14,3 mm) WRENCH FLATS 1-1/2" (38,1 mm) 7/16" (11,1 mm) NOMINAL MAKE-IN 1/2" NPT - - - - - - 6 4 2 5 3 1 FIGURE 1 SERIES TY-B TY3351 HORIZONTAL SIDEWALL SPRINKLER 5.6 K-FACTOR STANDARD RESPONSE TFP161 Page 3 of 6 Vertical Sidewall Sprinkler Installation The Series TY-B Vertical Sidewall Sprinklers must be installed in accor- dance with the following instructions. Install vertical sidewall sprinklers in the pendent or upright position with the arrow on the Deflector pointing away from the wall. Step 1. With pipe thread sealant applied to the pipe threads, hand- tighten the sprinkler into the sprinkler fitting. Step 2. Tighten the sprinkler into the sprinkler fitting using only the W-Type 6 Sprinkler Wrench, see Figure 4. For wax-coated sprinklers, use an 8 or 10 in. adjustable Crescent wrench. Apply the W-Type 6 Sprinkler Wrench or the Crescent wrench, as applicable, to the wrench flats, see Figure 2. When installing wax-coated sprinklers with the adjustable Crescent wrench, exercise care to prevent damage to the wax coating on the sprinkler wrench flats or frame arms and, consequently, exposure of bare metal to the corro- sive environment. Open the jaws of the wrench sufficiently wide to pass over the wrench flats without damaging the wax coating. Before wrench-tighten- ing the sprinkler, adjust the jaws of the wrench to contact only the sprinkler wrench flats. After wrench tightening the sprinkler, loosen the wrench jaws before removing the wrench. ** *** * * PENDENT UPRIGHT SECTION CROSSSHOWNSHOWN 1-1/2" (38,1 mm) ESCUTCHEON PLATE SEATING SURFACE 2-3/16" (55,6 mm) WRENCH FLATS 1/2" NPT 7/16" (11,1 mm) NOMINAL MAKE-IN ARROW MUST POINT AWAY FROM AND BE PERPENDICULAR TO THE BACK WALL SURFACE 7 2-3/16" (55,6 mm) 3 1 6 5 2 4 Pipe thread connections per ISO 7-1 can be provided on special request. Temperature rating is indicated on Deector. 1 2 Sealing Assembly Button Frame - -Bulb 3 - 4 - 6 -Deector Compression Screw 5 - FLOW Ejection Spring 7 - WRENCH RECESS (END "A" USED FOR 1/2" NPT MODELS) WRENCH RECESS PUSH WRENCH IN TO ENSURE ENGAGEMENT WITH SPRINKLER WRENCHING AREA 2-7/8" DIA. (73,0 mm) MOUNTING SURFACE CLOSURE 1-1/4" (31,8 mm) 3/4" (19,1 mm) SERIES TY-B MOUNTING PLATE 3/4" (19,1 mm) 1/8" (3,2 mm) 1/4" (6,4 mm) FACE OF SPRINKLER FITTING 5/8±1/4" (15,9±6,4 mm) 2-1/4" DIA. (57,2 mm) FIGURE 2 SERIES TY-B VERTICAL SIDEWALL (TY3451) SPRINKLER 5.6 K-FACTOR, STANDARD RESPONSE FIGURE 4 W-TYPE 6 SPRINKLER WRENCH FIGURE 5 W-TYPE 7 RECESSED SPRINKLER WRENCH FIGURE 3 SERIES TY-B RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3/4 IN. TOTAL ADJUSTMENT STYLE 10 RECESSED ESCUTCHEON, 5.6 K-FACTOR, 1/2 IN. NPT TFP161 Page 4 of 6 After installation, inspect the sprin- kler wrench flats and frame arms and retouch (repair) the wax coating when- ever the coating has been damaged and bare metal is exposed. Retouch the wax coating on the wrench flats by gently applying a heated 1/8 in. diam- eter steel rod to the damaged areas of wax to smooth it back over areas where bare metal is exposed. NOTICE Only retouching of the wax coating applied to the wrench flats and frame arms is permitted, and the retouching is to be performed only at the time of the initial sprinkler installation. The steel rod should be heated only to the point at which it can begin to melt the wax, and appropriate precau- tions need to be taken when handling the heated rod in order to prevent the installer from being burned. Care and Maintenance The TYCO Series TY-B, 5.6 K-factor, Horizontal and Vertical Sidewall Sprin- klers must be maintained and serviced in accordance with this section. Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, obtain permission to shut down the affected fire protection system from the proper authorities and notify all personnel who may be affected by this action. The owner must assure that the sprin- klers are not used for hanging any objects and that the sprinklers are only cleaned by means of gently dusting with a feather duster; otherwise, non- operation in the event of a fire or inad- vertent operation may result. Absence of an escutcheon, which is used to cover a clearance, may delay the time to sprinkler operation in a fire situation. Sprinklers which are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or other- wise altered after leaving the factory. Modified sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth or by brushing it with a soft bristle brush. Care must be exercised to avoid damage to the sprinklers before, during, and after installation. Sprin- klers damaged by dropping, strik- ing, wrench twist/slippage, or the like, must be replaced. Sprinklers that have a cracked bulb or that have lost liquid from its bulb must be replaced, see Installation Section. The owner is responsible for the inspection, testing, and maintenance of their fire protection system and devices in compliance with this document, as well as with the applicable standards of the National Fire Protection Associa- tion, such as, NFPA 25, in addition to the standards of any other authorities having jurisdiction. Contact the install- ing contractor or product manufacturer with any questions. Automatic sprinklers are recommended to be inspected, tested, and maintained by a qualified Inspection Service in accordance with local requirements and/or national codes. TFP161 Page 5 of 6 K-Factor Sprinkler Type Temperature Rating Bulb Liquid Color Sprinkler Finish (11) Natural Brass Chrome Plated Polyesterc Lead Coated Wax Coated Wax-Over-Lead Coated 5.6 1/2 in. NPT Horizontal Sidewall (TY3351) Figure 1 135°F (57°C)Orange 1, 2, 3, 4, 9, 10 1, 2, 3, 9, 10 1, 2, 3, 9, 10 1, 2, 3, 9, 10155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 1b, 2b, 3b, 9b, 10 b 360°F (182°C)Mauve 1, 2, 4, 9, 10 1, 2, 9, 10 N/A Recessed Horizontal Sidewall (TY3351)a Figure 3 135°F (57°C)Orange 1, 2, 3, 9, 10 N/A155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 5.6 1/2 in. NPT Vertical Sidewall (TY3451) Pendent or Upright Figure 2 135°F (57°C)Orange 5, 6, 7, 9 5, 6, 7, 9 5, 6, 7, 9155°F (68°C)Red 175°F (79°C)Yellow 200°F (93°C)Green 286°F (141°C)Blue 5b, 6b, 7b, 9b 360°F (182°C)Mauve 5, 6, 9 N/A NOTES: 1. UL Listed for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in. (100 to 300 mm) top of deflector-to-ceiling distance 2. C-UL Listed for use in Light and Ordinary Hazard Occupancies at a 4 to 12 in. (100 to 300 mm) top of deflector-to-ceiling distance 3. FM Approved for use in Light Hazard Occupancies at a 4 to 12 IN. (100 to 300 mm) top of deflector-to-ceiling distance 4. LPCB Approved (Ref. No. 094a & 007k) at a 4 to 6 in. (100 to 150 mm) deflector-to-ceiling distance 5. UL Listed for use in Light and Ordinary Hazard Occupancies 6. C-UL Listed for use in Light and Ordinary Hazard Occupancies 7. FM Approved for use in Light Hazard Occupancies 8. LPCB Approved (Ref. No. 094a & 007k) 9. Approved by the City of New York under MEA 354-01-E 10. EAC Approved 11. Where Polyester Coated, Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as corrosion-resistant sprinklers. Where Lead Coated, Wax Coated, and Wax-over-Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as corrosion-resistant sprinklers. a. Installed with Style 10 (1/2 in. NPT) or Style 40 (3/4 in. NPT) 3/4 in. Total Adjustment Recessed Escutcheon, as applicable b. 150°F (66°C) maximum ceiling temperature c. Frame and deflector only N/A – Not Applicable TABLE A SERIES TY-B 5.6 K-FACTOR HORIZONTAL AND VERTICAL SPRINKLERS LABORATORY LISTINGS AND APPROVALS K-Factor Sprinkler Type Sprinkler Finish Natural Brass Chrome Plated Polyester1 Lead Coated Wax Coated Wax-Over-Lead Coated 5.6 1/2 in. NPT Horizontal Sidewall (TY3351)250 psi (17,2 bar)2 OR 175 psi (12,1 bar)Recessed Horizontal Sidewall (TY3351) Vertical Sidewall (TY3451)175 psi (12,1 bar) Notes: 1. Frame and deflector only 2. The maximum working pressure of 250 psi (17,2 bar) only applies to UL Listing, C-UL Listing and Approval by the City of New York TABLE B SERIES TY-B 5.6 K-FACTOR HORIZONTAL AND VERTICAL SPRINKLERS MAXIMUM WORKING PRESSURE TFP161 Page 6 of 6 NATIONAL FIRE PROTECTION ASSOCIATION and NFPA are registered trademarks of National Fire Protection Association; TEFLON is a trademark of The Chemours Company FC, LLC 1467 Elmwood Avenue, Cranston, RI 02910 | Telephone +1-401-781-8220 © 2022 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Limited Warranty For warranty terms and conditions, visit www.tyco-fire.com. Ordering Procedure Contact your local distributor for avail- ability. When placing an order, indicate the full product name and Part Number (P/N). Sprinkler Assemblies with NPT Thread Connections Specify: Series TY-B (specify SIN), (specify K-factor), (specify Horizontal or Vertical Sidewall) Sprinklers with (specify) temperature rating, (specify) finish or coating, P/N (See Table C) Recessed Escutcheon Specify: Style 10 Recessed Escutch- eon with (specify) finish, P/N (specify*) * Refer to Technical Data Sheet TFP770 Sprinkler Wrench Specify: W-Type 6 Sprinkler Wrench, P/N 56-000-6-387 Specify: W-Type 7 Sprinkler Wrench, P/N 56-850-4-001 Wax Sticks (for retouching wrench-damaged wax coating) Specify: (specify color, below) Colored Coded Wax Stick for retouching (specify temperature rating) tempera- ture-rated Series TY-B Sprinklers, P/N (specify) Note: Each wax stick is suitable for retouching up to 25 sprinklers. Note: The wax used for 286°F (141°C) sprinklers is the same as for 200°F (93°C) sprinklers, and therefore the 286°F (141°C) sprinkler is limited to the same maximum ceiling temperature as the 200°F (93°C) sprinkler, that is 150°F (66°C). Notes: 1. Eastern Hemisphere sales only 2. Available only for 155 °F (68 °C) or 200 °F (93 °C) temperature rated sprinklers 3. Available only for horizontal sidewall TY3351 for use in Deluge Systems (“OPEN” indicates sprinkler assembly without glass bulb, button, and sealing assembly) P/N 57 – XXX – X – XXX Color Sprinkler Temperature Rating Part Number Black 135°F (57°C)56-065-1-135 Red 155°F (68°C)56-065-1-155 Yellow 175°F (79°C 56-065-1-175 Blue 200°F (93°C) 286°F (141°C)56-065-1-286 SIN 578 HORIZONTAL SIDEWALL TY3351 575 VERTICAL SIDEWALL TY3451 TEMPERATURE RATING 135 135°F (57°C) 155 155°F (68°C) 175 175°F (79°C) 200 200°F (93°C) 286 286°F (141°C) 360 360°F (182°C) 000 OPEN3 SPRINKLER FINISH 1 NATURAL BRASS 3 PURE WHITE (RAL9010)1 POLYESTER 4 SIGNAL WHITE (RAL9003) POLYESTER 5 JET BLACK (RAL9005)2 POLYESTER 6 WAX COATED 286 °F (141 °C) MAX 7 LEAD COATED 8 WAX-OVER-LEAD 286 °F (141 °C) MAX 9 CHROME PLATED TABLE C SERIES TY-B HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS PART NUMBER SELECTION TABLE D SERIES TY-B HORIZONTAL AND VERTICAL SIDEWALL SPRINKLERS WAX RETOUCHING STICK PART NUMBER SELECTION Model F1FR56 UprightModel F1FR56 Pendent Model F1FR56 Horizontal Sidewall Model F1FR56 Vertical Sidewall Note: Not all versions of the product are shown. F1FR Series Sprinklers Summary Sprinkler Model K-Factor gpm/psi1/2 (lpm/bar1/2)Orientation Listings & Approvals Max. Working Pressure psi (bar) Sprinkler Identification Number (SIN) F1FR56 5.6 (80) Upright Intermediate Upright cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1425 Pendent cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Concealed Pendent cULus, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Horizontal Sidewall cULus, FM 175 (12) 250 (17) (cULus only)RA1435 Vertical Sidewall cULus, FM, LPCB, UKCA 175 (12)RA1485 Table A Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- tification Number (SIN), application, performance, and listings/ approval are not otherwise affected. Sprinklers with New frames will include the suffix “N” in the order. Features • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Reliable Model F1FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1FR series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. www.reliablesprinkler.com K-factor 5.6 (80) F1FR56 Series Quick Response Sprinklers Bulletin 074 January 2023 Model F1FR56 Upright Sprinkler SIN RA1425 Technical Specifications Style: Upright, Intermediate Upright Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) Factory Water Shield (cULus, FM) F-1 Guard (cULus, FM) F-3 Guard with Shield (cULus, FM) Guards and Shields (Legacy Frames) Factory Water Shield C-1 Guard (FM) C-3 Guard with Shield (cULus, FM) D-1 Guard (cULus) D-3 Guard with Shield (cULus) Sprinkler Wrench Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045 Model F1FR56 Upright Sprinkler Components and Dimensions Figure 1 Deflector Glass Bulb (3 mm) Wrench Flat Threads 1 3/8" [33mm] 3 1/4" [83mm] Cap/Seal Assembly Load Screw 2 1/4" [58mm] F1FR_HALF_UPR_INT Shown with Optional Factory Installed Water Shield ( Intermediate Upright) Bulletin 074 January 2023 Page 2 of 9 www.reliablesprinkler.com Model F1FR56 Pendent Sprinkler SIN RA1414 Technical Specifications Style: Pendent Recessed Pendent Concealed Pendent Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings(1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons Model F1 (cULus, LPCB, VdS, CE, WM) Model F2 (cULus, FM, LPCB, VdS, CE, WM) Model FP (cULus, VdS, CE, WM) Cover Plate Model CCP (cULus, VdS(2), CE(2)) Guards & Shields (New Frames)(3) F-1 Guard (FM) F-5 Guard/Shield Kit (FM) F-7 Guard (cULus) F-8 Guard/Shield Kit (cULus) S-1 Shield (cULus, FM) Guards & Shields (Legacy Frames)(3) C-1 Guard (FM) C-5 Guard/Shield Kit (FM) D-1 Guard (cULus, FM) D-4 Guard/Shield Kit (FM) D-5 Guard/Shield Kit (cULus, FM) S-1 Shield (cULus, FM) Sprinkler Wrenches Model W2 (pendent) Model W4 (recessed or concealed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(4) cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045, 0831-UKCA-CPR-5072 (CCP) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1FR56 Pendent Sprinkler Components and Dimensions Figure 2 F1FR_HALF_PEND_INT Deflector Glass Bulb (3 mm) Wrench Flat Threads 3 1/4" [83mm] 2 1/4" [57mm] 1" [25mm]Load Screw Cap/Seal Assembly Shown with Optional S-1 Water Shield (Ordered Separately) Note: Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 January 2023 Page 3 of 9 www.reliablesprinkler.com Model F1FR56 Horizontal Sidewall Sprinkler SIN RA1435 Technical Specifications Style: Horizontal Sidewall Recessed Horizontal Sidewall Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons(2) Model F1 (cULus) Model F2 (cULus, FM) Model FP (cULus) Guards & Shields (New Frames)(3) F-4 Guard (FM) F-7 Guard (cULus) Guards & Shields (Legacy Frames)(3) C1 Guard (FM) D1 Guard (cULus) Sprinkler Wrenches Model W2 (non-recessed) Model W4 (recessed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed(4) FM Approved(5) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1FR56 Horizontal Sidewall Sprinkler Components and Dimensions Figure 3 Bulletin 074 January 2023 Page 4 of 9 www.reliablesprinkler.com F1FR_HALF_HSW 2 3/4" [70mm] 1 1/8" [28mm] Threads Cap/Seal Assembly Load ScrewDeflector Glass Bulb (3 mm) Wrench Flat Frame Note: Please refer to Figure 9 for recessed installation. Model F1FR56 Vertical Sidewall Sprinkler SIN RA1485 Technical Specifications Style: Upright Vertical Sidewall Pendent Vertical Sidewall Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) F-2 Guard (FM) Guards & Shields (Legacy Frames) C1 Guard (FM) Sprinkler Wrenches Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(1) cULus Listed FM Approved LPCB(2) UKCA: 0832-UKCA-CPR-S5045 Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1FR56 Vertical Sprinkler Components and Dimensions Figure 4 Bulletin 074 January 2023 Page 5 of 9 www.reliablesprinkler.com F1FR_HALF_VSW 2 1/4" [57mm] 1 1/2" [38mm] Threads Cap/Seal Assembly Load ScrewDeflector Glass Bulb (3 mm) Wrench Flat Frame Models F1 & F1FR Pendent Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 2-7/8" (72 mm) Dia. 1-3/4" (44 mm) 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. Minimum Recess Maximum Recess 1" (25 mm) Face of Fitting to Face of Ceiling 1-1/8" (29 mm) at Max. Recess 3/8" (10 mm) at Min. Recess Models F1 & F1FR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1" (25 mm) 2-5/16" (59 mm) Dia. Minimum Recess Maximum Recess 1/2" (12 mm) 3-3/16" (78 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 2-7/8" (72 mm) Dia. 1-3/4" (44 mm) Minimum Recess Maximum Recess 1-1/4" (32 mm) Face of Fitting to Face of Ceiling 7/8" (22 mm) at Max. Recess 3/8" (10 mm) at Min. Recess 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. 2-1/2" (64 mm) Dia. Hole in Ceiling Models F1 & F1FR Pendent Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Reducing Fitting Reducing Fitting Reducing Fitting Note: Model FP recessed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Vented Cup Model F1FR56 CCP Conical Concealed Sprinkler 1/2" (13mm) Nominal Adjustment (Nominal Cover Plate Projection is 1" (25 mm)) 1" (25 mm) 2-5/16" (59 mm) Dia. Minimum Recess Maximum Recess 1/2" (12 mm) 3-5/16" (84 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 2-1/2" (64 mm) Dia. Hole in Ceiling F1_REC_PEND_CCP Reducing Fitting Note: Model CCP concealed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. Vented Cup Recessed and Concealed Installation: Pendent Sprinklers Figure 5 FP EscutcheonF1 Escutcheon (F2 Similar) CCP Cover Plate Bulletin 074 January 2023 Page 6 of 9 www.reliablesprinkler.com 2-1/4" (57 mm) Dia. Hole 1-15/16" (49 mm) Dia. 2-1/4" (57 mm) Dia. Hole 1-15/16" (49 mm) DIA. 2-7/8" (73 mm) Dia. 2-7/8" (73 mm) Dia. 2-1/8" (54 mm) Minimum Recess 1-5/8" (42 mm) Maximum Recess 2 1/8" (54 mm) Minimum Recess 1-3/8" (35 mm) Maximum Recess 2-5/8" (67 mm) Dia Hole. 2-5/16" (58 mm) Dia. 3-1/4" (83 mm) Dia. 1-1/4" (32 mm) +/-1/4" (6 mm) Face of fitting to face of wall 1-3/8" (35 mm) Minimum Recess 7/8" (22 mm) Maximum Recess 3/8" (16 mm) +/-1/4" (6 mm) Face of fitting to face of wall 1/2" (12 mm) +/- 3/8" (10 mm) Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling F1FR_REC_HSW Reducing Fitting Reducing Fitting Reducing Fitting 9/16" [14mm] Model F1FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Model F1FR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Model F1FR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment F2 Recessed escutcheon 1/2" (13 mm) Adjustment F1 Recessed escutcheon 3/4" (19 mm) Adjustment 4" - 12" (102 mm - 305 mm) Deflector to ceiling 9/16" [14mm] 4" - 12" (102 mm - 305 mm) Deflector to ceiling 9/16" [14mm] Note: Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Vented Cup Recessed Installation: Horizontal Sidewall Sprinklers Figure 6 Bulletin 074 January 2023 Page 7 of 9 www.reliablesprinkler.com Installation Model F1FR Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats of the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N.m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Standard Finishes Special Application Finishes Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2)Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2) Bronze Brass Chrome Electroless Nickel PTFE(3)(4)Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5)Satin Chrome Satin Chrome White Polyester(3)White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F (93°C) maximum temperature rated sprinklers only. Finishes(1)Table B Maintenance Reliable Model F1FR series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Wrenches Model W2 (upright, pendent) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed, similar but with zinc finish)Model W4 (recessed, concealed pendent) Bulletin 074 January 2023 Page 8 of 9 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 6 2 3 Bulletin 074 January 2023 Page 9 of 9 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(1)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model J (New frame with guard installed) • Model JD (Legacy frame with guard installed) Notes: 1. 286°F (141°C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon.