Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Willie Thompson Jr Permit Pack
d06 PV Installation Professional Cecil Lopeman #042013-75 SCOPE OF WORK INSTALLATION OF ROOFTOP MOUNTED PHOTOVOLTAIC SOLAR SYSTEM RESIDENTIAL ROOFTOP SOLAR PERMIT PACKAGE TYPICAL STRUCTURAL INFORMATION ROOF MATERIAL: Comp Shingle SHEATHING: OSB FRAMING: Manufactured Truss RACKING: UNIRAC SFM INFINITY ROOF ATTACHMENT: UNIRAC SFM BUTYL TOTAL ATTACHMENTS: 32 GENERAL NOTES Sealed For Existing Roof & Attachment Only Digitally signed by John A. Calvert Date: 2025.04.23 13:08:57-06'00' 4/23/2025 Willie Thompson Jr 15801 104th Ave SE Yelm, Washington 98597 (801) 361-2674 Tip 1041h Ave SE # t a 40.. ob 1 r 0 NEW PV SYSTEM INFORMATION DC SYSTEM SIZE: 6.9 kW DC AC SYSTEM SIZE: 5.7 kW AC MODULE TYPE: (15) REC Solar REC460AA Pure-RX INVERTER TYPE: (15) Enphase IQ8X-80-M-US AHJ City of Yelm WA UTILITY COMPANY Puget Sound Energy a Enphase Platinum Installer SHEET INDEX PV1 COVER SHEET PV2 SITE PLAN PV3 ROOF PLAN PV4 STRUCTURAL PV5 ELECTRICAL 3-LINE PV6 ELECTRICAL CALCULATIONS PV7 LABELS PV8 PLACARD SS SPEC SHEETS BLUE RAVEN )I -AR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 Blue RavenSolar.com i COQ � Q Q O LU � � E } O pof 0 O � 00 U E } CEC-AC SYSTEM SIZE: 3.388 kW AC z W o U TOTAL PV DC SYSTEM SIZE TOTAL PV AC SYSTEM SIZE U Q � 6.900 kW DC 5.700 kW AC PROJECTID: 1298879 DESIGN CRITERIA WIND SPEED: 110 mph WIND EXPOSURE FACTOR: C SEISMIC DESIGN CATEGORY: D RISK CATEGORY: II GROUND SNOW LOAD: 25 psf PV DC SYSTEM SIZE: 6.900 kW DC PV AC SYSTEM SIZE: 5.700 kW AC REVISIONS: 0 0 WEATHER STATION DATA 0 WEATHER STATION: TACOMA NARROWS HIGH TEMP 2% AVG: 28°C EXTREME MINIMUM TEMP: -4°C APPLICABLE CODES *2023 NATIONAL ELECTRIC CODE (NEC) *2021 INTERNATIONAL BUILDING CODE (IBC) *2021 INTERNATIONAL RESIDENTIAL CODE (IRC), 2021 INTERNATIONAL PLUMBING CODE (IPC), AND ALL STATE AND LOCAL BUILDING, ELECTRICAL, AND PLUMBING CODES DRAWN BY: Jacob Massey PLOT DATE: April 23, 2025 DRAWING TITLE: Cover Sheet DRAWING NUMBER: PV1 VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. SITE PLAN SCALE: 1/ 16" = 1'-0" S UTILITY METER Fm MAIN SERVICE SP PANEL [SUB] SUBPANEL UTILITY METER CT CT CABINET LEGEND FB ENCLOSURE REAKER BAT ESS - BATTERY F]HATCH FIRE BACK AC AC DISCONNECT [ESC] ESS - CONTROLLER °q MICROINVERTER PV PV PRODUCTION REMOTE POWER RPO , ROOFTOP METER OFF SWITCH JUNCTION BOX H COMBINER BOX ATS ATS GENERATOR PANEL INV INVERTER FRONT OF HOME 15801 104th Ave SE TRENCH OR OVERHEAD PROPERTY LINE ICONS WITH DOTTED OUTLINE INDICATE INTERIOR LOCATION Sealed For Existing Roof & Attachment Only PV SYSTEM SPECIFICATIONS NEW PV SYSTEM INFORMATION PV MODULE: (15) REC Solar REC460AA Pure-RX, POWER RATING: 460 W INVERTER: (15) Enphase IQ8X-80-M-US, POWER RATING: 380 W 4/23/2025 COMPASS N S BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com i o- Tftf � Q � 3 Q O LL Q} 0 p r O O 3 00 a� U E r � } Z a a Z a W O � U 2 Q PROJECTID: 1298879 PV DC SYSTEM SIZE: 6.900 kW DC PV AC SYSTEM SIZE: 5.700 kW AC 0 0 0 Jacob Massey PLOT DATE: April 23, 2025 E Site Plan DRAWING NUMBER: PV2. VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. ROOF PLAN SCALE: 1/8"= 1'-0" S UTILITY METER F MAIN SERVICE SP PANEL [SUB] SUBPANEL UTILITY METER CT CT CABINET UNDERGROUND SERVICE LINE I-3'-1 POINT OF INTERCO FBE]BREAKER ENCLOSURE AC AC DISCONNECT PV PRODUCTION PV Pv] METER H COMBINER BOX MOD( AZIML PITCH TSRF: AREA: LEGEND BAT ESS - BATTERY [ESC] ESS - CONTROLLER REMOTE POWER RPO OFF SWITCH H GENERATOR ATS PANEL FIRE SETBACK ]HATCH MA MICROINVERTER ROOFTOP JUNCTION BOX H INVERTER FRONT OF HOME Sealed For Existing Roof & Attachment Only 1� MODULE QTY: 12 AZIMUTH: 180 PITCH: 27 TS R F: 84 AREA: 503 ftz PV SYSTEM SPECIFICATIONS TRENCH OR NEW PV SYSTEM INFORMATION OVERHEAD PV MODULE: (15) REC Solar REC460AA Pure-RX, POWER RATING: 460 W INVERTER: (15) Enphase IQ8X-80-M-US, POWER RATING: 380 W PROPERTY LINE ICONS WITH DOTTED OUTLINE INDICATE INTERIOR LOCATION 4/23/2025 COMPASS N S BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com L O- O 00 Q> 0`- O Q O > w Q }E p r O O 3 a� 00 U r } � Z a a Z a W O u o U a PROJECTID: 1298879 PV DC SYSTEM SIZE: 6.900 kW DC PV AC SYSTEM SIZE: 5.700 kW AC 0 0 0 Jacob Massey PLOT DATE: April 23, 2025 E Roof Plan DRAWING NUMBER: PV3. PANEL AZIMUTH PITCH TSRF AREA FRAMING SIZE CEILING JOIST/ MAXIMUM MAXIMUM PRIMARY PV ARRAY AREA (W) 336.24 COUNT (DEG) (DEG) (%) (%) (ft') ROOF MATERIAL SHEATHING TYPE FRAMING TYPE AND SPACING PURLINS SIZE RACKING TYPE ATTACHMENT TYPE ATTACHMENT CANTILEVER PRIMARY ROOF AREA (ft') 2450.24 AND SPACING SPACING (S) (C) PRIMARY ROOF COVERAGE (%) 13.72 MPl 12 180 27 84 503 Camp Shingle OSB Manufactured Truss 2x4 (4D 24 in OC 2x4 @ 24 in OC UNIRAC SFM INFINITY UNIRAC SFM BUTYL 72" L / 48"P 24" L / 16"P SECONDARY PV ARRAY AREA [W) IF APPLICABLE SECONDARY ROOF AREA (ff') SECONDARY ROOF COVERAGE (%) BLUE RAVEN MP2 3 180 27 67 401 Comp Shingle OSB Manufactured Truss 2x4 @ 24 in OC 2x4 @ 24 in OC UNIRAC SFM INFINITY UNIRAC SFM BUTYL 721 / 48"P 24"L / 16" P MP3 0 MP4 1 0 TOTAL PV ARRAY WEIGHT (Ibs) TOTAL PV ATTACHMENTS POINT LOAD 750 32 SOLAR MPS 0 1403 N 630 E MP6 0 (Ibs/aff.) DISTRIBUTED LOAD (psf) 23.4 2.23 Orem, Utah 84097 MP7 0 MP8 0 (800) 377-4480 BlueRavenSolar.com MP9 0 MP10 0 ATTACHMENT TYPE: PV MODULES SHALL NOT EXTEND Unirac SFM Butyl ABOVE ROOF RIDGE LINE PV MODULE MAX CANTILEVER PER TABLE ABOVE PV MODULES SHALL NOT EXTEND MORE THAN fat 6 INCHES FROM THE PLANE OF THE ROOF L UNIRAC UNIRAC PV MODULE SFM INFINITY SFM INFINITY LJJ L0 i 2" MICRORAIL 6.5"SPLICE O � rF C LC Q } ROOF MATERIAL NOT EXISTING FRAMING E SHOWN FOR CLARITY — D ^�^ t O O 1 3/a' MIN. i N } (2) #14-14x3"SCREW I EMBEDMENT 0 > > 4 W/ EPDM WASHERT T 00 I 1 \J •� �% E •� Q ATTACHMENT SPACING >- PER TABLE ABOVE 31, FRAMING SPACING *THIS DETAIL IS NOT MEANT TO BE PER TABLE ABOVE FRAMING DETAIL EXTERIOR WALL AN EXACT REPRESENTATION OF ATTACHMENT DETAIL SCALE: 1 /2" = 1'-0" FRAMING OR PV MODULE LAYOUT SCALE: 1-1 /2" = 1'-0" Z a RIDGE 0 NOTES i I LANDSCAPE PORTRAIT u a Im PROJECTID: 1298879 Sealed For 1, . C" y Existing Roof & , { WAS PV DC SYSTEM SIZE: 6.900 kW DC Attachment Only ° T PV AC SYSTEM SIZE: +A 5.700 kW AC REVISIONS: I I I1 B Q 4GOS6 ' DIVAL QD DRAWN BY: Jacob Massey 4/23/2025 PLOT DATE: April 23, 2025 DRAWING TITLE: Structural FOLLOW ATTACHMENT SPACING IN TABLE ABOVE DRAWING NUMBER: SAVE *ATTACHMENT PATTERN SHOULD BE ATTACHMENT PATTERN STAGGERED UNLESS OTHERWISE PV4 SCALE: 1/4" = 1'-0" NOTED IN ENGINEERING LETTER UNDERGROUND SERVICE 120/240 VAC, 60 Hz 1 PHASE, 3 WIRE Ll (1) 10 AWG THHN/THWN-2 CU BLACK 4 L2 (1) 10 AWG THHN/THWN-2 CU RED N (1) 10 AWG THHN/THWN-2 CU WHITE G (1) 10 AWG THHN/THWN-2 CU GREEN 3/4 INCH EMT Exterior Ll (2) IOAWGTHHN/THWN-2CUBLACK 3/41NCH L2 (2) 10 AWG THHN/THWN-2 CU RED EMT* G (1) 10 AWG THHN/THWN-2CU GREEN *TYPE OF CABLE MAY BE SUBSTITUTED FOR USE IN CONDUIT WHERE ELECTRICAL CODE PERMITS 2 Ll (1) 10 AWG THHN/THWN-2 CU BLACK 3/41NCH L2 (1) 10 AWG THHN/THWN-2 CU RED G (1) 10 AWG THHN/THWN-2CU GREEN *TYPE NM (ROMEX) OR OF CABLE IS PERMITTED FOR INTERIOR OR ATTIC RUNS AND SHALL BE USED WHEN ELECTRICAL CODE PERMIT 1 Ll (1) 12 AWG THHN/THWN-2 CU BLACK L2 (1) 12 AWG THHN/THWN-2 CU RED G (1) 6 AWG BARE, CU ENPHASE Q-CABLE, 2-WIRE, FREE AIR Exterior LEGEND (E) EXISTING (PV) PV BREAKER (N) NEW (FIB) FACTORY INSTALLED BREAKER (EL) EXISTING LOADS SPD SURGE PROTECTIVE DEVICE (RL) RELOCATED LOADS MI MECHANICAL INTERLOCK OFINAL CONFIGURATION OF PV CIRCUITS TO BE DECIDED BY INSTALLER. MUST COMPLY WITH MAX MICROINVERTERS PER CIRCUIT AS LISTED ON ATTACHED SPEC SHEET. O O O OS VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 1 O' OF UTILITY METER. O 0 0 GROUNDING ELECTRODE SYSTEM SHALL BE IN ACCORDANCE WITH NEC 250.53. ADPV MODULE: REC Solar REC460AA Pure-RX, 460 W DC, UL 1703 / UL 61730 COMPLIANT D MICROINVERTER: ENPHASE IQ8X-80-M-US, 380 W AC (0.380 kW), 1 PHASE, UL 1741 COMPLIANT CD ROOFTOP JUNCTION BOX: EZ SOLAR JB-1.2 JUNCTION BOX D JUNCTION BOX: PVC 4 X 4 JUNCTION BOX D PV COMBINER BOX: ENPHASE COMBINER 5 (X-IQ-AM1-240-5) F) SQUARE-D SAFTEY SWITCH 30A, 2P, 240VAC, NON -FUSIBLE (DU221 RE) PRIMARY PV COMBINER BOX ��{LT>by�FLEry41+Y �� Vp iL Elm 'I s— OTHER NOTES ALL INTERIOR CONDUIT MUST BE SCH 80 PVC. VISIBLE, LOCKABLE, KNIFE HANDLE AC DISCONNECT TO BE LOCATED WITHIN 10' OF UTILITY METER. Y STRUCTURES Q(15) PV MODULES �B & MICROINVERTERS BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800) 377-4480 BlueRavenSolar.com L a` O Q a\ � Q O w } OO 0 0 O � 00 U E � r z a a O O } � u 2 Q J PROJECTID: 1298879 PV DC SYSTEM SIZE: 6.900 kW DC PV AC SYSTEM SIZE: 5.700 kW AC REVISIONS A Jacob Massey PLOT DATE: April 23, 2025 DRAWING TITLE: Electrical 3-Line DRAWING NUMBER: PV5 BLUE RAVEN 1403 N 630 E Orem, Utah 84097 (800)377-4480 BlueRavenSolar.com L o- O "' � Q> N > O Q} w '� >_ D O r 0 O 3 0 U a� E r •� O W � Z Z a a W O U O F t~Il � U 2 a PROJECTID: 1298879 PV DC SYSTEM SIZE: 6.900 kW DC PV AC SYSTEM SIZE: 5.700 kW AC REVISIONS: A DRAWN BY: Jacob Massey PLOT DATE: April 23, 2025 DRAWING TITLE: Electrical Calculations DRAWING NUMBER: PV6 ELECTRICAL INFORMATION UTILITY ELECTRICAL SYSTEM 1-Phase, 3-Wire, 60Hz, 120/240V NEW PV SYSTEM 1-Phase, 3-Wire, bOHz, 120/240V AC SYSTEM SIZE 5. kW AC DC SYSTEM SIZE 6.9kW DC PV MODULES QUANTITY 15 TYPE REC Solar REC460AA Pure-RX WATTAGE 460W DC INVERTERS TYPE Enphase 108X-80-M-US OUTPUT CURRENT 1.58A AC NOMINAL VOLTAGE 240V AC OUTPUT POWER 380W AC PV BREAKER BACKFEED CALCULATIONS "120% RULE" (BUSBAR RATING * 120%) - OCPD RATING =AVAILABLE BACKFEED MAIN SERVICE SUBPANEL 1 SUBPANEL 2 PANEL BUSBAR RATING 200A ----A ----A PANEL OCPD RATING 200A --A --A MAILABLE BACKFEED (120%RULE) 40A ##A ##A PV BREAKER RATING 30A 30A 30A *THESE CALCULATIONS ARE ONLY APPLICABLE IF PV INTERCONNECTION IS A LOAD SIDE BREAKER. *PV BREAKER MUST BE RATED LESS THAN OR EQUAL i0 AVAILABLE BACKFEED FOR CODE COMPLIANCE* DESIGN LOCATION AND TEMPERATURES DATA SOURCE ASHRAE Weather Station Data STATE Washington CITY Yelm WEATHER STATION TACOMA NARROWS HIGH TEMP 2% AVG 28°C EXTREME MINIMUM TEMP -4°C WIRE SIZE SPECIFICATIONS MINIMUM CONDUCTOR AMPACITY 15.8A AC 15.8A AC 15.8A AC 29.63A AC --A AC --A AC A AC --A AC --A AC --A AC CONDUCTOR MATERIAL Cu Cu Cu Cu ---- ---- ---- ---- ---- ---- CONDUCTOR TYPE THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 THHN/THWN-2 -- -- -- -- -- -- CONDUCTOR SIZE 12 AWG 10 AWG 10 AWG 10 AWG ---- CONDUCTOR AMPACITY 30A 40A 40A 40A --A --A --A --A --A --A AMBIENT TEMPERATURE ADJUSTMENT FACTOR 1 1 1 1 ---- ---- ---- ---- ---- ---- PV CIRCUIT SPECIFICATIONS PRIMARY STRUCTURE DETACHED STRUCTURE CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUIT 5 CIRCUIT 6 CIRCUIT 7 CIRCUIT 8 CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUITS NUMBER OF MODULES PER CIRCUIT 8 7 0 0 0 0 0 0 0 0 0 0 0 RATED AC OUTPUT CURRENT (lay,) 12.6A 1 1.1 A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA 0.0A O.OA MINIMUM AMPACITY (lour x 125%) 15.8A 13.8A O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA O.OA OVERCURRENT PROTECTION RATING 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A 20A COMBINED AC OUTPUT CURRENT (Cap.) 23.7A O.OA MINIMUM AMPACITY (Coy, x 125%) 29.6A O.OA COMBINED PV BREAKER RATING 30AA OAA TOTAL PV VOLTAGE DROP VOLTAGE DROP WIRE TAG #1 0.62% WIRE TAG #2 0.85% WIRE TAG #3 0.26% WIRE TAG #4 0.12% WIRE TAG #5 0% WIRE TAG #6 0% TOTAL 1.850000% WARNING LABELS UTILITY METER AWARNING DUAL POWER SUPPLY SOURCES: UTILITY GRID AND PV SOLAR ELECTRIC SYSTEM IN CASE OF EMERGENCY, PLEASE CONTACT: BLUE RAVEN SOLAR (800) 377-4480 MAIN SERVICE PANEL SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUTDOWN PV SYSTEM AND REDUCE SHOCK HAZARD LLI N THE ARRAY. A CAUTION MULTIPLE SOURCES OF POWER POWER TO THIS BUILDING IS ALSO SUPPLIED FROM A ROOF MOUNTED SOLAR ARRAY. PV DISCONNECT IS LOCATED WITHIN 10 FT AND LINE OF SIGHT OF UTILITY METER. WARNING POWER SOURCE OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE *LABEL INSTALLED NEXT TO PV BREAKER PV AC DISCONNECT PHOTOVOLTAIC DISCONNECTA AC RATED AC OUTPUT CURRENT 23.7 A NOMINAL OPERATING AC VOLTAGE 240 V OWARNING ELECTRIC SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION PV COMBINER BOX PHOTOVOLTAIC SYSTEM COMBINER PANEL WWAMM AUTHORIZED PERSONNEL ONLY DO NOT ADD LOADS NO DC WIRES PRESENT RAPID SHUTDOWN TEST NOT REQUIRED BLUE RAVEN SOLAR 1403 N 630 E Orem, Utah 84097 (800)377-4480 BlueRavenSolar.com L O- N CO Q 0. � O LLJ Q E o p r O O 3 0 a� ULo •� Lo � a z a a Z a W O U O t~Il F � U 2 a PROJECTID: 1298879 PV DC SYSTEM SIZE: 6.900 kW DC PV AC SYSTEM SIZE: 5.700 kW AC A ZL 0 Jacob Massey PLOT DATE: April 23, 2025 Warning Labels DRAWING NUMBER: PV7 SOLAR'S MOST TRUSTED . dillb, REC ALPHAO PURE-RX 5ERIE DATASHEET L *U ` ELIGIBLE +1p.,..1 L, , - '� �- �' `� � � ter•= f .fi dr r hLa_ REC GENERAL DATA Cell Type 88 half -cut bifacial REC heterojunction cells, with gapless technology Glass 3.2 mm solar glass with anti -reflective surface treatment in accordance with EN12150 Backsheet Highly resistant polymer (Black) Frame Anodized aluminum (Black) Junction Box 4-part, 4 bypass diodes, IP68 rated, in accordance with IEC 62790 Connectors Staubli MC4 PV-KBT4/KST4 (4 mmz) In accordance with IEC 62852, IP68 only when connected Cable 4 mm2 solar cable,1.7 m+1.7 m in accordance with EN50618 Dimensions 1728 x 1205 x 30 mm (2.08 mz) Weight 22.7 kg Origin Made in Singapore ELECTRICAL DATA Power Output - PMAx (Wp) Watt Class Sorting - (W) Nominal Power Voltage - VMPP(V) Nominal Power Current- IMPP(A) F Open Circuit Voltage - Voc (V) to Short Circuit Current - Isc (A) Power Density (W/m2) Panel Efficiency (%) 450 0/+10 54.3 8.29 65.1 8.81 216 21.6 Power Output - PMAX (WP) 343 Nominal Power Voltage - VMPP (V) 51.2 ZNominal Power Current - Impp (A) 6.70 Open Circuit Voltage - Voc (V) 61.3 Short Circuit Current - Isc (A) 7.11 PRODUCT CODE*: RECxxxAA Pure-RX 460 0/- .0 54.9 8.38 65.3 8.88 221 22.1 d - u W 470 0/+10 55.4 8.49 65.6 8.95 226 22.6 358 52.2 6.86 61.8 7.23 Values at standard test conditions (STC: air mass AM 1.5, irradiance 1000 W/nn , temperature 25*Q, based on a production spread with a tolerance of P_ Vor & Isr±3% within one watt class. Nominal module operating temperature (NMOT: air mass AM 1.5, irradiance 8D0 W/m', temperature 20°C, windspeed 1 m/s). 'Where xxx indicates the nominal power class (Pmea) at STC above. MAXIMUM RATINGS* Operational Temperature -40 °C -85'C System Voltage 1000 V Maximum Test Load (front) +7000 Pa (713 kg/m2) Maximum Test Load (rear) -4000 Pa (407 kg/mz) Max Series Fuse Rating 25 A Max Reverse Current 25 A *See installation manual for mounting instructions. Design load =Test load /1.5 (safety factor) TEMPERATURE RATINGS* Nominal Module Operating 44°C±2°C Temperature Temperature coefficient of PMAx -0.24%/°C Temperature coefficient of Voc -0.24%/°C Temperature coefficient of Isc 0.04%/°C *The temperature coefficients stated are linear values DELIVERY INFORMATION J& do Panels per Pallet 33 Panels per 40 ft GP/high 594 (18 Pallets) cube container Panels per 13.6 in truck 660 (20 Pallets) SOLAR'S MOST TI ry ai CERTIFICATIONS IEC 61215:2021; IEC61730:2016; U1_61730 r S011925-2 Ignitability(EN 13501-1 Class E) EC 62716 Ammonia Resistance IEC61701 SaltMist(SM6) IEC 61215:2016 Hailstone (35 mm) UL61730 Fire Type 2 w ISO 14001; IS09001; IEC45001; IEC62941 0 DBE CII► w Y u take Qvva a n In[ertek Takee-way WEEE- Lri c°mplian( hem, WARRANTY &_ Standard REC ProTrust Installed by an REC Certified No Yes Yes Professional System Size All <25 kW 25-500 kW Product Warranty 20 25 25 (yrs) Power Warranty 25 25 25 (yrs) Labor Warranty 0 25 10 (yrs) Power inYear 1 98% 98% 98% o- r" Annual Degradation 0.25% 0.25% 0.25% N Power in Year 25 92% 92% 92% v The REC ProTrust Warranty is only available on panels purchased through an REC Certified Solar Professional installer. Warranty ou conditions apply. See www.recgroup.com for more details 97 0 IOW LIGHT BEHAVIOUR o Typical low irradiance performance of module at STC: a a -__ -- -- Irradiance (W/m-) Founded in1996, REC Group is an international pioneering solar energy company dedicated to empowering consumers with clean, affordable REC Solar PTE. LTD. ��� solar power. As Solar's Most Trusted, REC is committed to high quality, innovation, and a low carbon footprint in the solar materials and solar 20 Tuas South Ave. 14 panels it manufactures. Headquartered in Norway with operational headquarters in Singapore, REC also has regional hubs in North America, Singapore 637312 Europe, and Asia -Pacific. post@recgroup.com www.recgroup.com BLUE RAVEN SOLAR DRAWING NUMBER: SS PHASE.EN PRELIMINARY DATASHEETMicroinverterBLUE RAVEN INPUT DATA (DC) UNIT IQBX-80-M-USSOLAR IQ8X Microinverter Our newest IQ8 Series Microinverters are the industry's first microgrid-forming*, software -defined microinverters with split -phase power conversion capability to convert DC power to AC power efficiently. The brain of the semiconductor -based microinverter is our proprietary application - specific integrated circuit (ASIC), which enables the microinverter to operate in grid -tied or off -grid mode. This chip is built using advanced 55-nm technology with high-speed digital logic and superfast response times to changing loads and grid events, alleviating constraints on battery sizing for home energy systems. IQ8X Microinverter is the latest addition to this family, designed to support PV modules with high input DC voltage and cell counts, such as 80-half-cut cells, 88-half-cut cells and 96-cells. Part of the Enphase Energy System, IQ8 Series Microinverters integrate with the IQ Battery, IQ Gateway, and the Enphase App monitoring and analysis software. I[* Connect PV modules quickly and easily to the IQ8 Series Microinverters with integrated MC4 connectors. *Meets UL 1741 only when installed with IQ System Controller 2 and 3. IQ8 Series Microinverters redefine reliability standards with more than one million cumulative hours of power -on testing, enabling an industry -leading limited warranty of up to 25 years. IQ8 Series Microinverters are UL Listed as PV rapid shutdown equipment and conform with regulations when installed according to the manufacturer's instructions. © 2023 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. Easy to install Lightweight and compact with plug - and -play connectors Power line communication (PLC) between components Faster installation with simple two -wire cabling High productivity and reliability Produces power even when the grid is down* More than one million cumulative hours of testing Class II double -insulated enclosure Optimized for the latest high-powered PV modules Microgrid-forming Complies with the latest advanced grid support Remote automatic updates for the latest grid requirements Configurable to support a wide range of grid profiles Meets CA Rule 2T (UL 1741-W and IEEE 1547,2018(UL 1741-SB) NOTE: • IQ8 Series Microinverters cannot be mixed with previous generations of Enphase microinverters 0Q7 Series, IQ6 Series, and so on) in the same system. • IQ Gateway is required to change the default grid profile at the time of installation to meet local Authority Having Jurisdiction (AHJ) requirements. Commonly used module pairings' Module compatibility MPPT voltage range Operating range Minimum and maximum start voltage Maximum input DC voltage Maximum continuous operating DC current Maximum input DC short-circuit current Maximum module I Overvoltage class DC port DC port backfeed current PV array configuration Peak output power Maximum continuous output power Nominal grid voltage (L-L) Minimum and maximum grid voltage 2 Max. continuous output current Nominal frequency Extended frequency range AC short circuit fault current over three cycles Maximum units per 20 A (L-L) branch circuit a Total harmonic distortion Overvoltage class AC port AC port backfeed current Power factor setting Grid -tied power factor (adjustable) Peak efficiency CEC weighted efficiency Nighttime power consumption Ambient temperature range Relative humidity range DC connector type Dimensions (H x W • D); Weight Cooling Approved for wet locations; Pollution degree Enclosure Environmental category; UV exposure rating W 320-540 — To meet compatibility, PV modules must be within the following maximum input DC voltage and maximum module I. Module compatibility can be checked at https://enphase.com/installers/microinverters/calculator v 43-60 v 25-79.5 v 30-79.5 v 79.5 A 10 A 16 A 13 — I I mA 0 _ Ungrounded array; no additional DC side protection required; AC side protection requires maximum 20 A per branch circuit VA 384 366 VA 380 360 V 240.spat-ptwae1-0,1W 208, single-phase (L-L), 120* 4 v 21f-264 183-229 A LM 1.73 Hz 60 Hz 47-68 A_ 2.70 — 10 9 % <5 mA 18 1.0 — 0.85 leading ... 0.85 lagging % 97.3 97.0 % 9&5 96.5 m W 26 12 -40*C to 65'C (-40'F to 149°F) 4 % to 100 % (condensing) Staubli MC4 212 mm (8.3") x 175 mm (6.9") x 30.2 mm 0.2");1.1 kg (2.43 Ibs) Natural convection - no fans Yes; PD3 Class II double -insulated, corrosion -resistant polymeric enclosure NEMA Type 6; outdoor CA Rule 21(UL 1741-SA), UL 62109-1, IEEE 1547:2018 (UL 1741-SB), FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 Certifications This product is UL Listed as PV rapid shutdown equipment and conforms with NEC 2014, NEC 2017, NEC 2020, and NEC 2023 section 690.12 and C22.1-2018 Rule 64-218 rapid shutdown of PV systems for AC and DC conductors when installed according to the manufacturer's instructions. (1) No enforced DC/AC ratio. (2) Nominal voltage range can be extended beyond nominal if required by the utility. (3) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area. (4) IQ8X is not certified for use with Enphase Three Phase Network Protection Relay (NPR-3P-208-NA) and therefore designed IQ8X-MC4-DSH-00185-2.0-EN-US-2023-11-16 for single-phase operation only. Check with the local utility requirements if you wish to install single phase inverter across three phases. IQ8X-MC4-DSH-00185-2.0-EN-US-2023-11-16 DRAWING NUMBER: SS Data Sheet Enphase Q Cable Accessories REGION: Americas Enphase Q Cable Accessories To learn more about Enphase offerings, visit enphase.com The Enphase Q Cable'"' and accessories are part of the latest generation Enphase IQ System'"'. These accessories provide simplicity, reliability, and faster installation times. Enphase Q Cable • Two -wire, double -insulated Enphase Q Cable is 50% lighter than the previous generation Enphase cable • New cable numbering and plug and play connectors speed up installation and simplify wire management • Link connectors eliminate cable waste Field-Wireable Connectors • Easily connect Q cables on the roof without complex wiring • Make connections from any open connector and center feed any section of cable within branch limits Available in male and female connector types Enphase Q Cable Accessories CONDUCTOR SPECIFICATIONS Certification UL3003 (raw cable), UL 9703 (cable assemblies), DG cable Flame test rating FT4 Compliance RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada and United States Conductor type THHN/THWN-2 dry/wet Disconnecting means The AC and DC bulkhead connectors have been evaluated and approved by UL for use as the load -break disconnect required by NEC 690. Q CABLE TYPES / ORDERING OPTIONS Connectorized Models Size / Max Nominal Voltage Connector Spacing PV Module Orientation Connector Count per Box Q-12-10-240 12 AWG / 277 VAC 1.3 m (4.2 ft) Portrait 240 Q-12-17-240 12 AWG / 277 VAC 2.0 m (6.5 ft) Landscape (60-cell) 240 Q-12-20-200 12 AWG / 277 VAC 2.3 m (7.5 ft) Landscape (72-cell) 200 ENPHASE Q CABLE ACCESSORIES Name Model Number Description Raw Q Cable Q-12-RAW-300 300 meters of 12 AWG cable with no connectors Field-wireable connector (male) Q-CONN-10M Make connections from any open connector Field-wireable connector (female) Q-CONN-10F Make connections from any Q Cable open connector Cable Clip Q-CLIP-100 Used to fasten cabling to the racking or to secure looped cabling Disconnect tool Q-DISC-10 Disconnect tool for Q Cable connectors, DC connectors, and AC module mount Q Cable sealing caps (female) Q-SEAL-10 One needed to cover each unused connector on the cabling Terminator Q-TERM-10 Terminator cap for unused cable ends Enphase EN4 to MC4 adaptor' ECA-EN4-S22 Connect PV module using MC4 connectors to IQ micros with EN4 (TE PV4-S SOLARLOK). 150mm/5.9" to MC4. Enphase EN4 non -terminated adaptor' ECA-EN4-FW For field wiring of UL certified DC connectors. EN4 (TE PV4-S SOLARLOK) to non -terminated cable. 150mm/5.9" Enphase EN4 to MC4 adaptor (long)' ECA-EN4-S22-L Longer adapter cable for EN4 (TE PV4-S SOLARLOK) to MC4. Use with split cell modules or PV modules with short DC cable. 600mm/23.6" Replacement DC Adaptor (MC4) Q-DCC-2 DC adaptor to MC4 (max voltage 100 VDC) Replacement DC Adaptor (UTX) Q-DCC-5 DC adaptor to UTX (max voltage 100 VDC) 1. Qualified per UL subject 9703 TERMINATOR SEALING CAPS Terminator cap for unused cable Sealing caps for unused aggregator ends, sold in packs of ten and cable connections (Q-TERM-10) (Q-BA-CAP-10 and Q-SEAL-10) DISCONNECT TOOL Plan to use at least one per CABLE CLIP Used to fasten cabling to the racking installation, sold in packs of ten or to secure looped cabling, sold in (Q-DISC-10) packs of one hundred (Q-CLIP-100) To learn more about Enphase offerings, visit enphase.com © 2020 Enphase Energy. All rights reserved. Enphase, the Enphase logo, Enphase IQ 7A, Enphase IQ Battery, Enphase Enlighten, Enphase IQ EN P H A S E. Envoy, and other trademarks or service names are the trademarks of Enphase Energy, Inc. Data subject to change. �1 E N P H A S E 2020-06-26 BLUE RAVEN SOLAR DRAWING NUMBER: SS n ENPHASE IQ Combiner 5/5C The IQ Combiner 5/5C consolidates interconnection equipment into a single enclosure and streamlines IQ Series Microinverters and IQ Gateway installation by providing a consistent, pre -wired solution for residential applications. IQ Combiner 5/5C uses wired control communication and is compatible with IQ System Controller 3/3G and IQ Battery 5P. The IQ Combiner 5/5C, IQ Series Microinverters, IQ System Controller 3/3G, and IQ Battery 5P provide a complete grid -agnostic Enphase Energy System. IQ Series Microinverters The high-powered smart grid -ready IQ Series Microinverters (I06, IQ7, and IQ8 Series) simplify the installation process. 11 10 Battery 5P Fully integrated AC battery system. Includes six field -replaceable IQ8D-BAT Microinverters. C@" LISTED 5-year limited warranty IQ System Controller 3/3G Provides microgrid interconnection device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid "-wPr tc backup power. IQ Load Controller Helps prioritize essential appliances during a grid outage to optimize energy consumption and prolong battery life. NON *For country -specific warranty information, see the https://enphase.com/installers/resources/warranty page. ® 2024 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ, and certain other marks listed at https://enphase.com/trademark-usage-guidelines are trademarks of Enphase Energy, Inc. in the U.S. and other countries. Data subject to change. IQ Combiner 5/5C I BLUE RAVEN SOLAR IQ Combiner 5 with IQ Gateway printed circuit board for integrated revenue -grade PV production IQ Combiner 5 (X-IQ-AM1-240-5) metering (ANSIC12.20 ±0.5%), consumption monitoring (± 2.5%), and IQ Battery monitoring U2.5%). Includes a silver solar shield to deflect heat. IQ Combiner 5C with IQ Gateway printed circuit board for integrated revenue -grade PV production IQ Combiner 5C (X-I0-AM1-240-5C) metering (ANSI C12.20±0.5%), consumption monitoring U2.5%) and IQ Battery monitoring U2.5%). Includes Enphase Mobile Connect cellular modem (CELLMODEM-M1-06-SP-05)'. Includes a silver solar shield to deflect heat. IQ Gateway printed circuit board IQ Gateway is the platform for total energy management for comprehensive, remote maintenance, and management of the Enphase Energy System Busbar 80 A busbar with support for 1 • IQ Gateway breaker and 4.20 A breaker for installing IQ Series Microinverters and IQ Battery 5P IQ Gateway breaker Circuit breaker, 2-pole, 10 A/15 A Production CT Pre -wired revenue -grade solid -core CT, accurate up to ±0.5% X-IQ-AM1-240-5 Consumption CT Two consumption metering clamp CTs, shipped with the box, accurate up to±2.5% X-IQ-AM1-240-5C IQ Battery CT One battery metering clamp CT, shipped with the box, accurate up to±2.5% CTRL board Control board for wired communication with IQ System Controller 3/3G and the IQ Battery 5P Enphase Mobile Connect (only with IQ Combiner 5C) 4G-based LTE-M1 cellular modem (CELLMODEM-MI-06-SP-05) with a 5-year T-Mobile data plan Accessories kit Spare control headers for the COMMS-KIT-02 board Smart Includes IQ Gateway for REPLACEMENT PARTS ACCESSORIES r r INCLUDED, ORDER communication and control CELLMODEM-MI-06-SP-05 4G-based LTE-M1 cellular modem with a 5-year T-Mobile data plan Includes Enphase Mobile Connect CELLMODEM-MI-06-AT-05 4G-based LTE-MI cellular modem with a 5-year AT&T data plan (CELLMODEM-M1-06-SP-05), only with IQ Combiner 5C Supports Eaton BR2XX, Siemens Q2XX and GE/ABB THQL21XX Series circuit breakers (XX represents Circuit breakers (off -the -shelf) 10,15, 20, 30, 40, 50, or 60). Also supports Eaton BR220B, BR230B, and BR240B circuit breakers Supports flexible networking: Wi-Fi, compatible with the hold-down kit. Ethernet, or cellular Provides production metering Circuit breakers (provided b Enphase) P y P BRK-10A-2-240V, BRK-15A-2-240V, BRK-20A-2P-240V, BRK-15A-2P-240V-B, and BRK-20A-2P- "Accessories" (revenue grade) and consumption 24OV-S (more details in the section) monitoring XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner 5/5C XA-ENV2-PCBA-5 IQ Gateway replacement printed circuit board (PCB) for IQ Combiner 5/5C Easy to install X-IQ-NA-HD-125A Hold-down kit compatible with Eaton BR-B Series circuit breakers (with screws) Mounts to one stud with centered brackets XA-COMMS2-PCBA-5 Replacement COMMS-KIT-02 printed circuit board (PCB) for IQ Combiner 5/5C Supports bottom, back, and side ELECTRICAL SPECIFICATIONS conduit entries Rating 80 A Supports up to four 2-pole branch circuits for 240 VAC plug-in breakers System voltage and frequency 120/240 VAC, 60 Hz (not included) Busbar rating 125 A 80 A total PV branch circuits Fault current rating 10 kAIC Bluetooth-based Wi-Fi provisioning for easy Wi-Fi setup Maximum continuous current rating (input from PV/storage) 64 A Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR, Siemens Q, or GE/ABB THQL Series distributed generation (DG) breakers Reliable only (not included) Durable NRTL-certified NEMA type 3R Maximum total branch circuit breaker rating (input) 80 A of distributed generation/95 A with IQ Gateway breaker included enclosure IQ Gateway breaker 10 A or 15 A rating GE/Siemens/Eaton included 5-year limited warranty Production metering CT 200 A solid core pre -installed and wired to IQ Gateway 2-year labor reimbursement program coverage included for both the Consumption monitoring CT (CT-200-CLAMP) A pair of 200 A clamp -style current transformers is included with the box IQ Combiner SKUs IQ Batter metering CT y gy 200 A clamp -style current transformer for IQ Batter metering, g, included with the box UL1741 Listed 1. A plug -and -play industrial -grade cell modem for systems of up to 60 microinverters. Available in the United States, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area. DRAWING NUMBER: IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 SS Dimensions (W • H x D) 37.5 cm • 49.5 cm • 16.8 cm (14.75" • 19.5.6.63"). Height is 21.06" (53.5 cm) with mounting brackets Weight 7.5 kg (16.5 Ibs) Ambient temperature range -400C to 460C (-40°F to 115°F) Cooling Natural convection, plus heat shield Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction 20 A to 50 A breaker inputs:14 to 4 AWG copper conductors 60 A breaker branch input: 4 to 1/0 AWG copper conductors Wire sizes Main lug combined output:10 to 2/0 AWG copper conductors Neutral and ground: 14 to 1/0 copper conductors Always follow local code requirements for conductor sizing Communication (in -premise connectivity) Built-in CTRL board for wired communication with IQ Battery 5P and IQ System Controller 3/3G. Integrated power line communication for IQ Series Microinverters Altitude Up to 2,600 meters (8,530 feet) Integrated Wi-Fi 802.11b/g/n (dual band 2.4 GHz/5 GHz), for connecting the Enphase Cloud through the internet Wi-Fi range (recommended) 10 m (32.8 feet) Bluetooth BLE4.2,10 m range to configure Wi-Fi SSID Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included), for connecting to the Enphase Cloud through the internet Cellular/Mobile Connect CELLMODEM-MI-06-SP-05 or CELLMODEM-M1-06-AT-05 (included with IQ Combiner 5C) Digital I/O Digital input/output for grid operator control USE; 2.0 Mobile Connect, COMMS-KIT-01 for IQ Battery 3/3T/10/10T, COMMS-KIT-02 for IQ Battery SP Access point (AP) mode For connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs, one IQ Battery CT, and one Production CT Power line communication 90-110 kHz Web API See https://developer-v4.enphase.com Local API See guide for local API IQ Combiner with IQ Gateway PV Microinverters IQ System Controller COMMS-KIT-012 IQ System Controller 2 IQ Battery IQ System Controller 3 COMMS-KIT-02' IQ Battery UL 1741, CAN/CSA C22.2 No.107.1, Title 47 CFR, Part 15, Class B, ICES 003, NOM-208-SCFI-2016, UL 60601-1/CANCSA 22.2 No.61010-1, IEEE 1547:2018 (UL 1741-SB, 3rd Ed.), IEEE 2030.5/CSIP Compliant, Production metering: ANSI C12.20 accuracy class 0.5 (PV production) IQ6, IQ7, and IQ8 Series Microinverters EP20OG101-M24OUS00 EP20OG101-M24OUS01 ENCHARGE-3-1P-NA, ENCHARGE-10-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-iP-NA SC200D111C240US01, SC200G111C240US01 IQBATTERY-5P-IP-NA 2. For information about IQ Combiner 5/5C compatibility with the 2nd-generation batteries, refer to the compatibility matrix. 3. IQ Combiner 5/5C comes pre -equipped with COMMS-KIT-02. IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 Accessories C Mobile Connect 4G-based LTE-M1 cellular modem with a 5-year data plan (CELLMODEM-Mi-06-SP-05 for Sprint and CELLMODEM-MI-06-AT-05 for AT&T) CT-200-SOLID 200 A revenue -grade solid core Production CT with <0.5 % error rate (replacement SKU) 40 Circuit breakers BRK-10A-2-240V Circuit breaker, 2-pole, 10 A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2-pole,15 A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 BRK-15A-2P-24OV-B Circuit breaker, 2-pole, 15 A, Eaton BR215B with hold-down kit support BRK-20A-2P-24OV-B Circuit breaker, 2-pole, 20 A, Eaton BR220B with hold-down kit support CT-200-CLAMP 200 A clamp -style consumption and battery metering CT with <2.5% error rate (replacement SKU) IQC-5-5C-DSH-00007-3.0-EN-US-2024-03-01 BLUE RAVEN SOLAR DRAWING NUMBER: SS ENPHASE DATA SHEET IQ Gateway IQ Gateway IQ Gateway integrates revenue grade PV production metering (ANSI C12.20 ±0.5%), consumption ENV-IQ-AMi-240 metering (±2.5%), and battery metering (±2.5%) with IQ Battery 5P. ENV2-IQ-AM1-240 (IEEE'1547:2018) Includes one 200 A continuous rated Production Current Transformer (CT). Mobile Connect Includes COMMS-KIT-01 and CELLMODEM-M1-06-SP-05 with 5-year Sprint data plan COMMS-CELLMODEM-Ml-06 4G based LTE-M1 cellular modem with 5-year Sprint data plan CELLMODEM-M1-06-SP-05 4G based LTE-M1 cellular modem with 5-year AT&T data plan CELL MODE M-M1-06-AT-05 Consumption monitoring CT and IQ Battery 5P metering CT CT-200-SPLIT Split -core and clamp style CTs with 2.5% accuracy enable whole home and IQ Battery 5P metering CT-200-CLAMP Communications Kit Installed at the IQ Gateway. For communications with IQ Battery and IQ System Controller. Includes COMMS-KIT-01 USB cable for connection to IQ Gateway or IQ Combiner and allows wireless communication with IQ COMMS-KIT-02 Battery and IQ System Controller. AC power requirements 120/240 V,120/208Y V, or 127/220Y V. Three -wire. 60 Hz. IQ Gateway breaker 2-pole and maximum 20 A overcurrent protection required QGateway Typical power consumption 5 W The IQ Gateway delivers solar production and energy consumption data to Enphase Installer Portal monitoring and analysis software for comprehensive, remote maintenance, and management of Enphase systems. With integrated production metering and optional consumption monitoring, the IQ Gateway is the platform for total energy management. It integrates with the IQ System Controller and IQ Battery. IQ Series Microinverters The high-powered smart grid -ready IQ Series Microinverters (IQ6, IQ7, and IQ8 Series) dramatically simplify the installation process. IQ System Controller Provides microgrid interconnect device (MID) functionality by automatically detecting grid failures and seamlessly transitioning the home energy system from grid power to backup power. IQ Battery IQ Load Controller All -in -one AC coupled storage system that is Helps prioritize essential appliances reliable, smart, simple, and safe. It provides during a grid outage to optimize backup capability and installers can quickly energy consumption and prolong design the right system size to meet the needs battery life. of both new and retrofit solar customers. I@ LISTED © 2023 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ and certain other marks listed at https://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. Smart Enables web -based monitoring and control Provides bidirectional communications for remote upgrades Supports power export limiting and zero -export applications Simple Easy system configuration using Enphase Installer App Flexible networking with Wi-Fi, Ethernet, or cellular Reliable Designed for installation indoors or outdoors in a NEMA 3R rated enclosure 5-year limited warranty ENV2-IQ-AM1-240 complies with IEEE®1547:2018 (UL 1741-SIB, 3rd Ed.) IQ-G-DS H-00111-3.0-EN-US-2023-12-20 Number of microinverters polled Up to 300 Dimensions (WxHxD) 21.3cmx12.6cmx4.5cm(8.4inx5inx1.8in) Weight 1.09 lb -40°C to 65°C (-40°F to 149°F) [ENV-IQ-AM1-240] Ambient temperature range -40°C to 50°C (-40°F to 122°F) [ENV2-IQ-AM1-240] -40°C to 46°C (-40°F to 115°F) if installed in an enclosure Environmental rating IP30. For installation indoors or in an NRTL-certified, NEMA type 3R or better -rated enclosure, if installing outdoors. Altitude Up to 2,600 meters (8,530 feet) Integrated Wi-Fi 802.11b/g/n (2.4 GHz, 5 GHz), for connecting the Enphase Cloud via the internet. Wi-Fi range (recommended) 10 m Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included), for connecting to the Enphase Cloud via the internet. Mobile Connect CELLMODEM-M1-06-SP-05, CELLMODEM-MI-06-AT-05 (to be purchased separately, mandatory for sites with IQ Battery) Digital 1/0 Digital input/output for grid operator control USB 2.0 For Mobile Connect and Communications Kit Access point (AP) mode For a connection between the IQ Gateway and a mobile device running the Enphase Installer App Metering ports Up to two Consumption CTs, one Production CT, and one battery CT (for IQ Battery 5P) Power line communication (PLC) 90 kHz-110 kHz (Class B), to microinverters. Web API Refer to https://developer-v4.enphase.com Local API Refer to guide for local API LED indicators From top to bottom: Cloud connectivity, Wi-Fi access point mode, PV production state, PLC communications state Configured via Enphase Installer App and Enphase Installer Platform IQ-G-DS H-00111-3.0-EN-US-2023-12-20 BLUE RAVEN SOLAR DRAWING NUMBER: SS Maximum relays read 4 Capabilities supported Power production limiting (Production CT/s required), power export limiting (Production CT/s required and Consumption CT/s - Load with Solar configuration) Minimum IQ Gateway version v7.3.120 Cable configurations 18 AWG, UL-Std. 62,600 V,105°C, and minimum 0.03 inches average thickness Signal voltage range 2.5 V-5 V (digital high), 0 V-1.9 V (digital low) Terminal blocks Five terminals, up to 0.002 in2 Configuration via SCOPEOF DELIVERY Enphase Installer App, Enphase Installer Platform (site settings) Package dimensions (H x W x D) 6.3 in x 10.8 in x 3.9 in Package weight 2.2 lb Aluminium DIN rail 4.9 in Current transformers (CTs) One CT-200-SOLID included CA Rule 21(UL 1741-SA), IEEE' 1547:2018 - UL 1741-SE, 3rd Ed.(ENV2-IQ-AM1-240), UL 61010-1 CAN/CSA C22.2 No. 61010-1 Compliance Title 47 CFR, Part 15, Class B, ICES 003 IEC/EN 61010-1:2010, EN50065-1, EN61000-4-5, EN61000-6-1, EN61000-6-2 Metering: ANSI C12.20 accuracy class 0.5 (PV production only) IQ System Controller SC200D111C240US01, SC200G111C240US01, EP20OG101-M24OUS01, EP200G101-M240US00 IQ Battery IQBATTERY-5P-1P-NA, ENCHARGE-3T-1P-NA, ENCHARGE-10T-1P-NA Microinverter IQ6, IQ7, and IQ8 Series Microinverters 1.8 8.4 ®® All dimensions in inches Accessories Enphase Mobile Connect 4G-based LTE-Mi cellular modem with a 5-Year data plan (CELLMODEM-M1-06-SP-05 for Sprint and CELLMODEM-M1-06-AT-05 for AT&T) CT-200-SOLID 200 A revenue grade solid core Production CT y with <0.5%error rate (replacement SKU) D 8.4 -- III_III, All dimensions in inches Circuit breakers BRK-10A-2-240V Circuit breaker, 2-pole,10 A, Eaton BR210 BRK-15A-2-240V Circuit breaker, 2-pole,15 A, Eaton BR215 BRK-20A-2P-240V Circuit breaker, 2-pole, 20 A, Eaton BR220 BRK-15A-2P-240V-B Circuit breaker, 2-pole, 15 A, Eaton BR215B with hold-down kit support BRK-20A-2P-240V-B Circuit breaker, 2-pole, 20 A, Eaton BR220B with hold-down kit support CT-200-CLAMP 200 A clamp -style consumption and battery metering CT with <2.5% error rate (replacement SKU) Revision history DSH-00111-3.0 DSH-00111-2.0 DSH-00111-1.0 December 2023 Updated power requirement and added IG Gateway breaker values. August 2023 Updated temperature specification for ENV2-IQ-AM1-240. June 2023 Updated altitude and recommended maximum microinverters on a site. © 2023 Enphase Energy. All rights reserved. Enphase, the a and CC logos, IQ, and certain other marks listed at IQ-G-DSH-00111-3.0-EN-US-2023-12-20 https://enphase.com/trademark-usage-quidelines are trademarks of Enphase Energy, Inc. in the US and other countries. Data subject to change. IQ-G-DSH-00111-3.0-EN-US-2023-12-20 BLUE RAVEN SOLAR DRAWING NUMBER: SS 1 A,B,C 6.75 [172] .28 [7] (3 HOLES) ,C )CKOUTS 7.50 [191]� n NEMA TYPE 3R ILLUSTRATED A,B,C,D KNOCKOUTS NOTES: FINISH - GRAY BAKED ENAMEL ELECTRODEPOSITIED OVER CLEANED PHOSPHATIZED STEEL. UL LISTED - FILE E-2875 ALL NEUTRALS - INSULATED GROUNDABLE SUITABLE FOR USE AS SERVICE EQUIPMENT TOP OF NEMA TYPE 3R SWITCHES HAVE PROVISIONS FOR MAXIMUM 2 1/2" BOLT -ON HUB. SHORT CIRCUIT CURRENT RATINGS: • 10,000 AMPERES. 10,000 AMPERES WHEN USED WITH OR PROTECTED BY CLASS H OR K FUSES. 100,000 AMPERES WITH CLASS R FUSES. * FOR CORNER GROUNDED DELTA SYSTEMS. ■ PLUG FUSES $ LUGS SUITABLE FOR 60'C OR 75' CONDUCTORS. FEBRUARY 2014 A,B,C KNOCKOUTS WIRING DIAGRAMS FUSIBLE NOT FUSIBLE I I A C S N I I I p p p B D 0 f 0 b SN TERMINAL LUGS $ AMPERES MAX. WIRE MIN. WIRE TYPE 30 # 6 AWG # 12 AWG AL # 6 AWG # 14 AWG CU KNOCKOUTS SYMBOL A B C D CONDUIT SIZE .50 775 1 1.25 DUAL DIMENSIONS: INCHES MILLIMETERS HORSEPOWER RATINGS CATALOG VOTAGE WIRING 120VAC 240VAC NUMBER RATINGS DIAG. STD. MAX. STD. MAX. 10 10 10 30 10 30 D211NRB9 ■ 240VAC A 1/2 2 1 1/2 - 3 - D221NRB 240VAC A - - 1 1/2 3* 3 7 1/2* D321NRB 240VAC B - - 1 1/2 3 3 7 1/2 DU221RB 240VAC C - - - - 3 - DU321RB 240VAC D - - - - 3 7 1/2 REF DWG #1852 BLUE RAVEN SOLAR DRAWING NUMBER: ss EZf SOLAR making solar simple, A. System Specifications and Ratings JB-1.2, JB-1.XL Specification Sheet PV Junction Box for Composition/Asphalt Shingle Roofs • Maximum Voltage: 1,000 Volts • Maximum Current: JB-1.2: 80 Amps; JB-1.XL: 120 Amps • Allowable Wire: 14 AWG — 6 AWG • Spacing: Please maintain a spacing of at least'/2" between uninsulated live parts and fittings for conduit, armored cable, and uninsulated live parts of opposite polarity. • Enclosure Rating: Type 3R • Roof Slope Range: 2.5 — 12:12 • Max Side Wall Fitting Size: 1" • Max Floor Pass -Through Fitting Size: 1" • Ambient Operating Conditions: (-35°C) - (+75°C) • Compliance: - JB-1.2: UL1741, CSA C22.2 No. 290; JB-1.XL: UL1741, CSA C22.2 No. 290 - Approved wire connectors: must conform to UL1741, CSA C22.2 No. 290 ` �IrtRrtRlS • System Marking: Interek Symbol and File #5019942 5019942 • Periodic Re -inspections: If re -inspections yield loose components, loose fasteners, or any corrosion between components, components that are found to be affected are to be replaced immediately. EZ*SOLAR Table 1: Typical Wire Size, Torque Loads and Ratings 1 Conductor 2 Conductor Torque Type NM I Inch Lbs Voltage Current ABB ZS6 terminal block 10-24 awg 16-24 awg Sol/Str 0.5-0.7 6.2-8.85 600V 30 amp ABB ZS10 terminal block 6-24 awg 12-20 awg Sol/Str 1.0-1.6 8.85-14.16 600V 40 am ABB ZS16 terminal block 4-24 awg 10-20 awg Sol/Str 1.6-2.4 14.6-21.24 600V 60 amp ABB M6/8 terminal block 8-22 awg Sol/Str .08-1 8.85 600V 50 amp Ideal 452 Red w,e o tea, 8 18 awg Sol/Str Self -Torque Self -Torque 600V Ideal 451 Yellow wre�o ate, 10-18 awg Sol/Str Self -Torque Self -Torque 600V Ideal, In -Sure pu=m`G0n ` 10-14 awg Sol/Str Self -Torque Self -Torque 600V WAGO, 2204-1201 10-20 awg 16-24 awg Sol/Str Self -Torque Self -Torque 600V 30 amp WAGO, 221-612 10-20 awg 10-24 awg Sol/Str Self -Torque Self -Torque 600V 30 amp Dottie DRC75 6-12 awg Sol/Str Snap -In Snap -In ESP NG-53 4-6 awg Sol/Str 45 2000V 10-14 awg Sol/Str 35 ESP NG-717 4-6 awg Sol/Str 45 2000V 10-14 awg Sol/Str 35 Brumall 4-5,3 4-6 awg Sol/Str 45 2000V 10-14 awg Sol/Str 1 5 Table 2: Minimum wire -bending space for conductors through a wall opposite terminals in mm (inches) Wire size, AWG or kcmil (mm2) Wires per terminal (pole) 1 2 3 4 or More mm (inch) mm (inch) mm (inch) mm (inch) 14-10 (2.1-5.3) Not Specified - - 8 (8.4) 38.1 (1-1/2) 6 (13.3) 50.8 (2) PHONE:385-202-4150 1 WWW.EZSOLARPRODUCTS.COM EZf SOLAR making solar simple. ITEM NO. PART NUMBER DESCRIPTION OTY 1 JB-1.2 BODY POLYCARBONATE 1 WITH UV INHIBITORS 2 POLYCARBONATE 1 JB-1.2 LID WITH UV INHIBITORS 3 #10 X 1-1/4" PHILLIPS 6 PAN HEAD SCREW 4 #8 X 3/4" PHILLIPS PAN HEAD SCREW 6 [27?.68mm] _276.301Tim] 11,01 irr to-0n, 4-- wl 4 1 II SOLAR II i J&1 2 I i Patents:a 1,,protlu .c /patents i 1 [ 183.06mm] 7.21 in [265.18mm] 10.441n PHONE:385-202-4150 WWW.EZSOLARPRODUCTS.COM SIZE B DWG. N0, JB-112 REV SCALE:1:2 WEIGHT:1.45 LBS SHEET 10F 3 TORQUE SPECIFICATION: 15-20 LBS UL 1741, NEMA 31R CERTIFICATION: CSA C22.2 NO.290 WEIGHT: 1.45 LBS PROPRIETARY AND CONFIDENTIAL:THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF EZ SOLAR. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUTTHE WRITTEN PERMISSION OF EZ SOLAR IS PROHIBITED. BLUE RAVEN SOLAR DRAWING NUMBER: SS RIGID PVC CONDUIT FITTINGS JB444 JUNCTION BOXES ISSUE DATE: DATE D'EMISSION: 2009 04 30 RIGID PVC CONDUIT FITTINGS SUPERCEDES: REMPLACE: 2004 07 15 JB444 JUNCTION BOXES 5 4.010 (102mi C 31--I B IIF D --30H PRODUCT CODE PART NUMBER I NOMINAL SIZE I A I B C (in) (mm) I (in) I (mm) I (in) I (mm) I (in) I (mm) 076668 J444 STAHLIN 4 103 3.675 93 4.000 102 3.450 88 076259 AMJB444 ALLIED 4 103 3.675 93 4.000 102 3.450 88 077643* 2037-424T CANLET 4 103 3.675 93 4.000 102 3.450 88 077696 JB 444 4 103 4.000 101 4.395 112 3.950 101 PRODUCT CODE PART NUMBER I NOMINAL SIZE I D I E VOLUME (in) (mm) I (in) I (mm) (in) I (mm) (cu. In) (cu. Cm) 076668 J444 STAHLIN 4 103 4.180 106. 3.850 98 51.5 844.6 076259 AMJB444 ALLIED 4 103 4.180 106 3.850 98 51.5 844.6 077643* 2037-424T CANLET 4 103 4.180 106 3.850 98 51.5 844.6 077696 JB 444 4 103 4.170 106 3.930 100 51.5 844.6 PRODUCT CODE PART NUMBER NOMINAL SIZE GASKET CODE INSERT I CODE SCREW I CODE MYEET CODE (in) (mm) 076668 J444 STAHLIN 4 103 072538 (4) 076259 AMJB444 ALLIED 4 103 072538 (4) 077643* 2037-424T CANLET 4 103 072538(4) 077696 JB 444 4 103 097731 072538(4) 072539 (2) 072522(4) 097747 072513 (2) BOX WITH MOLDED MOUNTING FEET, INSERT ONLY; NO COVER, OR GASKET, UL LISTED 576J Page: CONDUIT — 41.1 COVER DIMENSIONS 4.010" ISSUE DATE: I - 0 BLUE RAVEN DATE D'EMISSION: 2009 04 3 SOLAR SUPERCEDES: I I REMPLACE: 2004 07 15 0.245" y (6 mm) 190" D IA 511 na II Mounting Feet oduct Code 097747 DRAWING NUMBER: Page: CONDUIT — 41. Heyco®-Tite Liquid Tight Cordgrips for Enphase Q Cables Straight-Thru, NPT Hubs with Integral Sealing Ring ALL NEW The Ultimate in Liquid Tight Strain Relief Protection `�PR000CT! GLAND PART NO. DESCRIPTION PART DIMENSIONS CONFIGURATION Q/SP A B C D E Conductors or Clearance Max. O.A. Thread Wrenching Nut Type Size No. Black 911�s Hole Die. Length Length Thickness Flat Size mm. in. Immin. Imm. in.1mm in.lmm. in.1mm. Oval Gland Q Cable I6,1 x 9,7I 1 IM3231GCZ I LTCG 1/2 6.1x9.7MM Q/snl .875I22,2I1.70I43,2I.61 115,51 .21 15,3I .98I24,9 Break•Thru Sldnnpd Owtr Gland ° Craven 5,1 xg Tl $ I IeiOA sMi SMOG +s 2.6., .rMkt 3.9 &VIJIwaiE6A.11 j00,ei,62I,s.7 25 6-4 r 34 33.0 Graur.l , 1�.31AIA Metal Locknuts INCLUDED. SEALING NUT INTEGRAL SEALING RING SUGGESTED CLEARANCE HOLE FOR NONTHREADED MOUNTING Material Nylon 6/6 with TPE Sealing Gland Certifications © Listed under Underwriters' Laboratories File E504900 &P CSA Certified by the Canadian Standards Association File 93876 Flammability Rating 94V-2 Temperature Range Static -40oF (-40oC) to 239°F (115°C) Dynamic -4°F (-20oC) to 212°F (100°C) IP Rating IP 68 ALL NEW PRODUCT! Heyco° Helios UVX Clip - Blind Mount PANEL THICKNESS RANGE WIRE DIAMETER PART NO. DESCRIPTION MOUNTING OVERALL RANGE HOLE DIA. HEIGHT Minimum Maximum 1-2 Wires A C in. i n in. I mm. in. mm. in. mm. 1-2 Wires 028 0,7 .250 6,4 23 (5,8 mm) - .32 (8,0 mm) S6520 Helios UVX Clip 100 Pack 260 6,6 .96 24,4 each cable S6560 Helios UVX Clip Bulk A MOUNTING HOLE Material Nylon 6/6 with extended UV Capabilities Flammability Rating 94V-2 Temperature Range Dynamic -4°F (-20°C) to 185°F (85°C) 1-800-526-4182 • 732-286-1800 (NJ) • FAX: 732-244-8843 • www.hoyco.com • Two new cordgrips now accommodate the Enphase 0 Cable - M3231 GCZ (1/2-NPT) and M3234GDA-SM (3/4- N PT). • The 1/2-version provides liquid tight entry for one Enphase 0 Cable - .24 x .38-(6,1 x 9,7 mm). • The 314-version provides liquid tight entry for up to two Enphase 0 Cables - , 4 x ,38' (6.1 x 9,7 mm) and an additional -130" (3,3 mm) dia. hole far a 08 solld grounding cable- • The 314-version utillZes our skinned - over technology so any unused holes will retain a liquld tight seal, • Rated for use with DG Cable. • The jersey pine tree mounting style installs easily with superior holding power. • UVX nylon protects from corrosion due to outdoor exposure. • Installs into .260-(6,6 mm) mounting hole. • Holds up to 2 cables between .230 - .315-(5,8 - 8,0 mm) each. • Cables install with fingertip pressure. • Molded from our robust UVX nylon 6/6 with extended UV capabilities for our Solar 20 Year Warranty. 1-4b BLUE RAVEN SOLAR DRAWING NUMBER: SS SFM II T— I L 1 1 —r I I 1,§i *&* 4 2 INSTALLS PER DAY Make two installs per day your new standard. SFM INFINITY has fewer roof attachments, one tool installation, and pre -assembled components to get you off the roof 40% faster. BETTER AESTHETICS Install the system with the aesthetics preferred by homeowners, with integrated front trim, trim end caps, dark components, and recessed hardware. MAXIMUM POWER DENSITY Easily mix module orientations to achieve optimal power density without incurring the increased bill of materials, labor, and attachments required by rail. SYSTEM OVERVIEW NAME TRIMRAIL DESCRIPTIONPART Structural front trim provides aesthetic and aligns modules. TRIMRAIL SPLICE Connects and electrically bonds sections of TRIMRAIL. TRIMRAIL FLASHKIT Attaches TRIMRAIL to roof. Available for comp shingle or tile. MODULE CLIPS Secure modules to TRIMRAIL. MICRORAIL Connects modules to SLIDERS. Provides post -install array leveling. SPLICE Connects and supports modules. Provides east -west bonding. ATTACHED SPLICE also available. SLIDER FLASHKIT Roof attachment and flashing. Available for comp shingle and tile. BONDING AND ACCESSORIES IKAL LAR STARTS HERE L.270 ��.. 20% FEWER ATTACHMENTS Save time and money on every project: SFM INFINITY requires fewer attachments than rail systems. SFM INFINITY 15 Attachments RAIL 20 Attachments 30% LOGISTICS SAVINGS With fewer SKUs and compact components, SFM INFINITY is easier to stock, easier to transport, and easier to lift to the roof. Plus, make more efficient use of your vehicle fleet. TRIMRAIL ENDCAPS Covers ends of TRIMRAIL for refined aesthetic. TRIMRAIL BONDING CLAMP Electrically bonds TRIMRAIL and modules N/S BONDING CLAMP Electrically bonds rows of modules Ono • • BLUE RAVEN SOLAR DRAWING NUMBER: SS mr----- SFM FRAME SYSTEM BONDING& GROUNDING 22 ------------- MICRORAILTM me ----------------------------------------------------------- INSTALLATION -GUIDE-'- PAGE Star Washer is Single Use Only TERMINAL TORQUE, Install Conductor and torque to the followir 4-6 AWG: 35in-lbs 8 AWG: 25 in-lbs 10-14 AWG: 20 in-lbs LUG DETAIL & TORQUE INFO Rsco Lay -In Lug (GBL-4DBT) • 10-32 mounting hardware • Torque = 5 ft-lb • AWG 4-14-Solid or Stranded TERMINALTORQUE, Install Conductor and torque to the following: 4-14 AWG: 35in-lbs LUG DETAIL & TORQUE INFO Ilsco Flange Lug (SGB-4) • 1/4" mounting hardware • Torque = 75 in -lb • AWG 4-14-Solid or Stranded WEEBLUG Single Use Only *4144 TERMINALTORQUE, Install Conductor and torque to the following: 6-14 AWG: 7ft-lbs LUG DETAIL & TORQUE INFO Wiley WEEBLug (6.7) • 1/4" mounting hardware • Torque = 10 ft-lb • AWG 6-14-Solid or Stranded NOTE: ISOLATE COPPER FROM ALUMINUM CONTACT TO PREVENT CORROSION System bonding is accomplished through modules. System grounding accomplished by attaching a ground lug to any module at a location on the module specified by the module manufacturer. E-W BONDING PATH: E-W module to module bonding is accomplished with 2 pre -installed bonding pins which engage on the secure side of the MicrorailTM and splice. N-S BONDING PATH: N-S module to module bonding is accomplished with bonding clamp with 2 integral bonding pins. (refer also to alternate method) 000 Alternate method Z_77_� TRIMRAIL BONDING PATH: Trimrail to module bonding is accomplished with bonding clamp with integral bonding pin and bonding T-bolt. (refer also to alternate method) BLUE RAVEN SOLAR DRAWING NUMBER: SS No=----- 'SFMFRAME COMPATIBLE MODULES; 28 on ------------- MICRORAIL------------------------------------------------------- TM SYSTEM- CERTI-FICATION-'- PAGE Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SFM system. Manufacture Module Model / Series P-Series ALeo DNA-120-(BF/MF)26, DNA-144-(BF/MF)26 Aptos DNA-120-(BF/MF)10-440W, DNA-108-(B F/M F)10-400W CHSM6612P, CHSM6612P/HV, CHSM6612M, Astronergy CHSM6612M/HV, CHSM6610M (BL)(BF)/(HF), CHSM72M-HC AXN6M610T,AXN6P610T Auxin AXN6M612T & AXN6P612T AXlblackpremium 60 (35mm), AXlpower 60 (35mm), Axitec AXlpower 72 (40mm), AXlpremium 60 (35mm), AXlpremium 72 (40mm). Boviet BVM6610, BVM6612 BYD P6K & MHK-36 Series CS1(H/K/U/Y)-MS CS3(K/L/U), CS3K-MB-AG, CS3K-(MS/P) Canadian Solar CS3N-MS, CS3U-MB-AG, CS3U-(MS/P), CS3W CS5A-M, CS6(K/U), CS6K-(M/P), CS6K-MS CS6P-(M/P), CS6U-(M/P), CS6V-M, CS6X-P Centrosolar America C-Series & E-Series CT2xxMxx-01, CT2xxPxx-01, CertainTeed CTxxxMxx-02, CTxxxM-03, CTxxxMxx-04, CTxxxHC11-04 Dehui DH-60M Eco Solargy Orion 1000 & Apollo 1000 Manufacture Module Model / Series ET-M672BHxxxTW Manufacture Module Model / Series LGxxxN2T-A4 ET Solar FF-MP-BBB-370 Freedom Forever FF-MPI-BBB-xxx, FF-MP-BBB-xxx, LGxxx(A1C/E1C/E1K/N1C/N1K/N2T/N2W/ 01C/01K/S1C/S2W)-A5 FreeVolt Mono PERC LGxxxN2T-B5 GCL GCL-P6 & GCL-M6 Series LGxxxN1K-B6 LGxxx(A1 C/M 1 C/M 1 K/N 1 C/N 1 K/01 C/01 K/ TD-AN 3, TD-AN4, Hansol UB-AN1, UD-AN1 LG Electronics OAC/OAK ) -A6 LGxxx(N1C/N1K/N2T/N2W)-E6 36M, 60M, 60P, 72M & 72P Series, LGxxx(N1C/N1K/N2W/S1C/S2W)-G4 Heliene 144HC M6 Monofacial/Bifacial Series, LGxxxN2T-J5 144HC M10 SL Bifacial LGxxx(N1K/N1W/N2T/N2W)-L5 HT60-156(M) (NDV) (-F), LGxxx(N1C/01C/01K)-N5 HT Solar HT 72-156(M/P) LGxxx (N1C/N1K/N2W/O1C/O1K)-V5 Hyundai KG, MG,TG, RI, RG,TI, MI, HI & KI Series LR4-60(H I B/H I H/H PB/H PH)-xxxM H iA-SxxxHG ITEK iT iT-HE & iT-SE Series LR4-72(HIH/HPH)-xxxM - LR6-60(BP/HBD/HIBD)-xxxM (30mm) Japan Solar JPS-60 & JPS-72 Series _ LR6-60(BK)(PE)(HPB)(HPH)-xxxM (35mm) LONGLR6-60(BK)(PE)(PB)(PH)-xxxM (40mm) JAPE 60-xxx,JAM6-60-xxx/SI,JAM6(K)-60/ LR6-72(BP)(HBD)(HIBD)-xxxM (30mm) xxx, JAP6(k)-72-xxx/4BB, JAP72SYY-xxx/ZZ, LR6-72(HV)(BK)(PE)(PH)(PB)(HPH)-xxxM JAP6(k)-60-xxx/4BB, JAP60SYY-xxx/ZZ, (35mm) JAM6(k)-72-xxx/ZZ,JAM72SYY-xxx/ZZ, JASoLar LR6-72(BK)( HV)( PE)( PB)( PH) (40mm) 40mm) JAM 6(k) -60-xxx/ZZ, JAM 60SYY-xxx/ZZ. i. YY: 01, 02, 03, 09,10 Meyer Burger Meyer Burger Black ii. ZZ: SC, PR, BP, HiT, IB, MW, MR Meyer Burger White Mission Solar Energy JAM54S31 xxx/MR MSE Series JKM & JKMS Series Mitsubishi I MJE & MLE Series Jinko Eagle JKMxxxM JKMxxxM-72HL-V Neo Solar Power Co. D6M & D6P Series Kyocera KU Series • Unless otherwise noted, all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes 7" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 15 for further information BLUE RAVEN SOLAR DRAWING NUMBER: SS No=----- 'SFMFRAME COMPATIBLE MODULES; 29 on ------------- MICRORAIL------------------------------------------------------- TM SYSTEM- CERTI-FICATION-'- PAGE Electrical Bonding and Grounding Test Modules The list below is not exhaustive of compliant modules but shows those that have been evaluated and found to be electrically compatible with the SFM system. Manufacture Module Model / Series EVPVxxx (H/K/PK), VBHNxxxSA15 & SA16, VBHNxxxSA17 & SA18, Panasonic VBHNxxxSA17(E/G) & SA18E, VBHNxxxKA01 & KA03 & KA04, VBHNxxxZA01, V13HNxxxZA02, VBHNxxxZA03,VBHNxxxZA04 Peimar SGxxxM (FB/BF) Phono Solar PS-60, PS-72 Prism Solar P72 Series Plus, Pro, Peak, G3, G4, G5, G6(+), G7, G8(+) Pro, Peak L-G2, L-G4, L-G5, L-G6, L-G7 OYEAK DUO BLK-G6+ Q.PEAK DUO BLK-G6+/TS Q.PEAK DUO (BLK)-G8(+) OYEAK DUO L-G8.3/BFF O.Cells OYEAK DUO (BLK) ML-G9(+) Q.PEAK DUO XL-G9/G9.2/G9.3 Q.PEAK DUO (BLK) ML-G10(+) OYEAK DUO XL-G(10/10.2/10.3/10.c/10.d) Q.PEAK DUO BLK ML-G10+ / t Q.TRON BLK M-G2+ SERIES Alpha (72) (Black) (Pure) RECxxxAA (PURE-R) (Pure-RX) RECxxxNP3 Black N-Peak (Black) REC N-Peak 2 (Black) PEAK Energy Series PEAK Energy BLK2 Series PEAK Energy 72 Series Manufacture Module Model / Series TwinPeak Series TwinPeak 2 Series TwinPeak 2 BLK2 Series REC (cont.) TwinPeak 2S(M)72(XV) TwinPeak 3 Series (38mm) TP4 (Black) Renesola Vitrus2 Series & 156 Series Risen RSM72-6 (MDG) (M), RSM60-6 SEG-xxx-BMD-HV SEG Solar SEG-xxx-BMD-TB S-Energy SN72 & SN60 Series (40mm) Seraphim SEG-6 & SRP-6 Series Sharp NU -SA & NU -SC Series SLA, SLG, BC Series & SlLxxx(BL/NL/NT/HL/ Silfab M L/B K/N X/N U/H C/Q M) SE-166*83-xxxM-120N PowerXT-xxx R-(AC/P D/B D) Solarever USA Solaria PowerXT-xxxC-PD PowerXT-xxxR-PM (AC) Sunmodule Protect, SOLarWorLd Sunmodule Plus SS-M-360 to 390 Series, SS-M-390 to 400 Series, Sonali SS-M-440 to 460 Series, SS-M-430 to 460 BiFacial Series, SS 230 - 265 SunEdison F-Series, R-Series & FLEX FXS Series Suniva MV Series & Optimus Series Manufacture Module Model / Series A -Series A400-BLK , SPR-MAX3-XXX-R, X-Series, E-Series & P-Series, SunPower Axxx-BLK-G-AC, SPR-Mxxx-H-AC SPR-Mxxx-BLK-H-AC Suntech STP, STPXXXS - B60/Wnhb TP572, TP596, TP654, TP660, Talesun TP672, Hipor M, Smart SC, SC B, SC 131, SC B2 Tesla TxxxH,TxxxS PA05, PD05, DD05, DE06, DD06, PE06, Trina PD14, PE14, DD14, DE09.05, DE14, DE15, PE15H UNlxxx-120M-1313, UN1xxx-120MH, Universal Solar UNlxxx-108M-1313, U P-M xxx P(- B), Upsolar UP-MxxxM(-B) D7MxxxH7A, D7(M/K)xxxH8A United Renewable Energy FAKxxx(C8G/E8G), FAMxxxE7G-BB (URE) FAMxxxE8G(-BB), FBMxxxMFG-BB URECO F6MxxxE7G-BB Eldora, Vikram Solivo, Somera VSUNxxx-(108/120)M-BB VSUN VSUNxxx-108BMH Waaree AC & Adiya Series Winaico WST & WSP Series YingLi YGE & YLM Series ZN Shine ZXM6-72, ZXM6-NH144-166_2094 • Unless otherwise noted, all modules listed above include all wattages and specific models within that series. Variable wattages are represented as "xxx" • Items in parenthesis are those that may or may not be present in a compatible module's model ID • Slashes "/" between one or more items indicates that either of those items may be the one that is present in a module's model ID • Please see the SFM UL2703 Construction Data Report at unirac.com to ensure the exact solar module selected is approved for use with SFM • SFM Infinity is not compatible with module frame height of less than 30mm and more than 40mm. See Module Mounting section, page 15 for further information BLUE RAVEN SOLAR DRAWING NUMBER: SS er ek AUTHORIZATION TO MARK 7a[al Qualtiy- Assured. This aulhonzes the application of the Certification Mark(s) shown below to the models described in the f foduct(s) Covered section when made in accordance wilh the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple listee model(s) identified an the correlation page of the Listing Report This document is the property of Intertek TeslirQ Services and is not transferat�ie. The certification mark(s) may be applied only at the IOCalion of the Parly Authorized) To Apply Mark. er ek AUTHORIZATION TO MARS( Taal Qual4y- Assumd. This authorizes the application of the Certification Mark(s) shown below to the models du5critied in the ffoduct(s) Covered section when made in accordance v ilh the conditions set forth in the Certification Agreement and Listing Report. This authorization also applies to multiple ki a model(s) Identified on the correlation page of the Listing Report. This document is the property of Intertek Testing Services and is not transferat�ie. The certification mark(s) may be applied only at the IOCalion of the Party ,authorized To Apply Mark. Applicant: Unirac, Inc Manufacturer; Cixi Emeka Aluminum Co. Ltd Applicant: Unirac, Inc Manufacturer. Global Aluminium Pvt Ltd Broadway Blvd t No. 688 ChaoSheng Road Broadway 1�1+vd NE SY NO.157. 158- 151& 162, KallakaI Address: lbu 0 Albuquerque, fVful $71D2 Address. Cixi City Address: lbu Albuquerque, fVful 87107 Address. Village, Manohaiabad Mndl Zhejiang Provinoe 31533 Meilak Dist 502336 Country: USA Country: Cflina Country: USA Country: India Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Inlertek Testing Services NA, Inc., Lake Forest, CA Control Number: 150037051 Authorized by: for L.L. at����..�,, Snyder, Certification Manager G us Intertek This document supersedes all previous Aulhorizations to Meru for the noted Report Number- thm,41w¢ahon io M mk IL ON ti�la r� W ai Indedir'i C.6mi ands pooddod puiY l Io Rm Cwbhubon aWarnunt hs#. Inlawak rid ds UWQ lyarlary raapan466ty a1FM'iaWity ra kTdad is 0t farms rod aordxns al IPe agrc r& Vd~aaumngz m 6at iq In an f Pit. odor than la In& Ch mi in acaordance *Lth 2w agnpwr ik Ior orrV bmw ppwi a ar damape aocar.orxd bythau ar the Aidh: mhw to RlarL Cnig the CUmM a nnnutnraw! to porn mpynq a ds7twbw or Orr Auidnoraaicn to Mork and firm arlr n dh may-kleaof bftr 's Cbfbnulmn ku rarndnd b Ore cs dbom Ia.o mi in H rt agraaer,r AM m Sis Autna aa%a Ia (dark Arvr njibar n d the "wek name ba Cie mole r aambsanad d h IaefYd nmb nW. pia d or serape rnaal brat l+appro &.n wiling ti, Rilanak Imliol Padrpy AWLaoWnarnts rod polo ,V 5nraan ma foe Uw purpo Dr arsnranq apprMiur swap a OW QWb&C rn inrt M VWWdrmc#y.+ri ltr aprnemenr dwyrenoAIDrIMp.rrparacalprodn hanquayaonborand dDnotrela In&0: 1ofVim ahlynbonsinItworerpod Intertek TDsiing Sarvtces NA Inv-. 545 Easl Algonquin Road, Ailington Heights, IL 60005 Telephone 800-I4S-3861 or 817-439-6667 Fax 312-283-1672 Mounting Systems. Mounling Devices, OlampinglReterilion devices, and Gfound Lugs for Use vrith Flat- Plate Photovoltaic Modules and Panels JtaL 2703:2015 Ed- 1+R:11JLr12024] St'anrlarci(s); PV Module and Panel (tacking Mounting System and Accessories [CSA T.1.L. A-40:20201 Product, Pholovoltaic Mounting Syslcem, Sun frame Microrail Installation Guide, PI-15213251MAR27 Brand Name: Unirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page t of 4 ATM Issued' 11-Apr-2025 EP 115 3 IS MonLms rf Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office: Inlertek Testing Services NA. Inc., Lake Forest, CA Control Number: 51—M989 Authorized by: for L. Mattfi w Snyder, Certification Manager us Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number - Thy AaAboneaaon to M mk Ia+a dw o-,roa.ww � d lnNrtek's Clan) and Y pomWod paiY l Io hryn Ca bhubun aqK nt be-. a Inlarlrk and rLL Cb ml Imnm[ek's d&spsni.WAty wd .aWy nua Imtod lo"farms rod aord_cns al lhr rprownarnt Inl*MA ass.rra no 6atNidy io a ,party, Udnar thanu lhr CAl in iwwrdarre wrh IN agManyrq lar any lard ppr ar danige accas.orxd by lbe t ar the Aura xahm 0 RlarL CW V Wm Clin N n arHwLad W pa nl oap+inp a OMAArbw or fiw MWhmzal- n to Mwk and than anik n dh mntiaky Uca Df WkHkik s Cerbhul6 �k u rEsDulod bgo m-dbf lac aW in the agreennrrt and.n ih.s+ w. zasa La Mark Any hillyn dthe "ofrt name krh de r admi-himrnart DI One Wak drrrmrW. pia d a serape n 1 bist be opprDmd.n miting bF inlanak Imliol F Ddory Aavnsrrrnlsand%dla ,V 5Drlfair nw Ace Hw purpr Dr assuxnp apprppn*y Luapf gito;irrLmYDn Hurt in ngn,pW}u w,h lha apue r Ihay wa noA IDr In* p.rrp+ al prgdn ban gaaldk radrol and dD not relb,a In* Ckant of Our ab pabws in Ibr■ rengod Intertek Testing Sarvims NA 1 nc. 545 Easl Algonquin Road, Arlington Heights, IL 60005 Telephone 800-3146-3851 or 817-439-6667 Fax 312-283-1672 Mounting Systems. Mounling Devices, Clam pinglRetenlion devices, and Gfound Lugs for Use with Rat- Plate Photovoltaic Modules and Panels (UL 2703:2015 Ed-1+R:11JLF120241 Standard(s); PV Module and Panel Racking Mounting System and Accessories [GSA T.1.L. A-40:2020] Product: Pholavoltaic Mounting System- Sun frame Micro -rail Installation Guide, P1J132425MAR27 Brand Name: Urlirac Models: Unirac SFM ATM for Report 102393982LAX-002 Page 2 of 4 ATM Issued' 11-Apr-2025 ED 76 3 i5 4'-.kd•9t 'D Uw4m try BLUE RAVEN SOLAR DRAWING NUMBER: SS Lntertek AUTHORIZATION IZATION TO MARS 'Focal Quality. Asmrpd. This authorizes the application of the Certification Mark(s) shown below to the models describ d in the Produd(s) Covered section When made in aoenrdance with the conditions set forth in the Certificafion Agreement and Listing Report_ This authorization also applies to rnuttiple ki a model(s) Identi9ed on the corrdatlon page of the LLsting Report. This document is the properly of Intertek Tesling Services and is not transferable_ The certification marks) may be applied only at the location of the Party Authorized To Apply Mark. tintertek AUTHORIZATION IZATION TO MARS 'Fatal Quality. Amured. This authorizes the application of the Certiftatiion Marks) shown below to the models described in the Product(s) Covered section when node in aoeardarwe with the conditions set forth in the Certifcaton Agreement and Listing Report. This authorization also applies to rrltllOpte Ilistee model(s) Identlfe on the clon'elatlon page of the Listing Report. This document is the property of Intertek Tesling Services and is not transferable. The certification marks) may be applied only at the location of the Party Authorized To Apply Mark. Applicant, Unirac, Inc Manufacturer; Nipunam Technologies Private Limited Applivant: Unirac, Inc Manufaraurer; Fujiyarna Technologies 1411 Broadway 13Ivd NE Plot No. 2. TSIIC Industrial Park Address: Atbuquerque, NM 87102 Address. Kucharam Village, Manaharabad Mandal, NlOak Distdct, Tetangana State; 502336 Country: USA Country: India Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office; Intertek Testing Services NA, Inc., Lake Forest, CA Control Number: 150195511 Authorized by: , i&ng -r• for 1- ew Snyder, Certification Manager C US wrR Intertek This document supersedes all previous Aukhofizations to Mark for the noted Report Number_ Thy hAwuwr la Mkrk is 41A r. r�ca.ww sae ai lnrarlak'i Chem and A psowdad pursuant In ha C�bhubm aqa nt hytaxan lnlerl& aetl As CWrl DArhW& daapv WWity u`tl Lah7"A IwThW1o"1prT and�_Cosal Dha iQMwmM Inlxlar asaanaa mIlobddito an/p". aM Mm ID try ChImIm Y wMa vththe Ygrmummit for my b3pk pplllM ar aYnS�ji [IOmlma� bytha use ar tt.s ALTr Rhm?s RIaM CnIK Wm ChwAy ajMDnrod is penal mpyxrpu dstn AAA Dr En ALPMarwA&L to Mrk WA then aMf n dh urdalf ow of bftrb 's Cabhubm n,•k hi ra&rdeC b Ore candba lea aul In Itw ugreennM ".n t-1.%Aumonmam b Mat Any haNfr r rA tho btwi&L name fu Ora ram a atl}i moNNad d he w8dYd nobnal. pmdud a aaneu mot Orat paappro�.�d n wllhng hF;nlanak ImbW Fatlmy Aavrsurrnla W FOW Lp Sa an ke br prxpora of asmrng appnppna141Lapf or" OFMO Mcrypt In VnWdan.M wdr Me pgnb*rrrrre bry re ml for pry P xp+ al prodLebm "INV radrei and do ent ralaw thf Clad of Ear abkpbo n bx■ nnpod Intertak Ta&fing al *Ac NA Inc. 5451`ad Algonquln Road. Arlington Heights, IL ti DCG Telephone800-345-3e51or847-439-5T Fax312-28&i672 Mounting Systems. Mounting Oevices. Clam pinglRetenlion Devices, and Mound Lugs for Use with Flat- Pin to Photovoltaic Modules and Panels [UL 2703.2015 Ed_I+R:11JUI2024] 5t2lildar#(S); PV Module and Panel lacking Mounting System a1id Accessories [GSA T.I.L. A-40:2020] Product: Photovoltaic Mounting System, Sun Frame Micrcrail Installation Guide, PUS2D25MAR27 Branca Name. Urweic Models; Unbar, 5FM ATM for Report 102393982LAX-002 Page 3 of 4 ATM Issued' 11-Apr-2025 ED 10 9 1511-.w =27 W. udDr'f 1411 Broadway elvd NE Plot No 97c. ALEAP Industrial Estate, Address: Albuquerque, NM 87102 Address. Pragslhi Nagar Hyderabad. Telangana, 500085 Country: USA Country: India Party Authorized To Apply Mark: Same as Manufacturer Report Issuing Office; Intertek Tesling Services NA, Inc., Lake Forest, CA Control Number. 02786$ Authorized by: for L. tlhew Snyder, Certification AIMan$gel• C u �,tn Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number_ hhm Auftvaiftw is Mrk IN for Ee eaa.rsrw raa or UOKt % CbW and A psowwlod purauanl bo 11eCVbhL0bM aEKrrment t'n#axan lnlerlak and ns Cle.I hnmhWN rrs}• shft pr W4 Bob"an mnrrd 16 Via to sae ambbYrr al ma aprwrb" In WLH azraraa m ILWA.V 1a "W paatf, darer man m IIro 01 w a wrda wnh the agrce-rwrl 'CW My MIR aalvhsa M dIrruP 000aawned by Vr use ar titre ADIT� xehon h Mart Grtf pre Cbaor a Motw umd io peernl mp+Inp m dsV, AAW oc th.r IMWh &!3 to Mrk and than only.n ^L enl+IaYf. OW of kNarhek s CdVb ldma RW k IL resbxAW b Ow cackAt"n lad aW In Um agreewmM W n Rim Audwnzalan IC Mark AM hzftw roe a the'► ofWk nam 1c+'he yak m adherbse'rrnl N Ef WoYd m>iarul prmdud m sarnoa mat OLt ka apprm�d n wnbng by Nrlarink WOW Fadury A4rasrrrnla W fello- ,V Sarxra an ke 11t pwpora Dr a .np apprc%ml uLW a thr Cxn'ca rrWk n arapeda %+h bu agraenarm Ihay re ral Im brr p.xp+ al prm&cbm q INV aorrbd and do ent relel Ihr Ckwd of Ear abkp bona m bx■ romAd Intertak Ta&fing Salvioas NA Inc. 545 East Algonquln Road. Arlington Heights, It_ t DCG Tekephone 800-345-3851 or 847-439-S ST Fax 312-28&i 672 Mounting Systems, Mounting Oevices, Clam pinglRetention Devices. and Ground Lugs for Use with Flat- Pin to Photovoltaic Modules and Panels [UL 2703.2015 Ed- 1+R--I1Ju12024] $tanddrcr(S); PV Module and Panel Racking Mounting System and Accessories [GSA T.I.L. A-40,20201 Product: Photovoltaic Mounting System_ Sun Frame Microrail Installation Guide, PUS2D25MAR27 Brand Name: UniraC Models; unlrac srm ATM for Report 102393982LAX-002 Page 4 of 4 ATM Issued, I I -Apr-2025 ED 10�151 I,7xF3CQZi f•1M�44 BLUE RAVEN SOLAR DRAWING NUMBER: SS PART # TABLE P/N DESCRIPTION SFMBTLMI SFM DTD BUTYL ATT, MILL 2X #14-14 SCREW, HWH, SS, SELF -DR W/ #14 EPDM WASHER DTD ATTACHMENT O O? 3/4" O O: O O no I V 1411 BROADWAY BLVD. NE ALBUQUERQUE, NM 87102 USA PHONE: 505.242.6411 WWW.UNIRAC.COM BUTYI 1/8" BUTYL 11, - 2 1/2" PRODUCT LINE: SFM INFINITY DRAWING TYPE: PARTS ASSEMBLY DESCRIPTION: SFM DTD BUTYL ATTACHMENT REVISION DATE: 3/1/2023 PART TABLE P/N DESCRIPTION 004095D FLASHLOC SFM TRIM KIT w/ CAP, 20 PACK 3 3/4" DRAWING NOT TO SCALE ALL DIMENSIONS ARE Q mom U N I RAL NOMINAL , 1411 BROADWAY BLVD. NE PRODUCT PROTECTED BY U- ALBUQUERQUE, NM 87102 USA ONE OR MORE US PATENTS PHONE: 505.242.6411 WWW,UNIRAC,COM LEGAL NOTICE SHEET PRODUCT LINE: SFM DRAWING TYPE: ASSEMBLY DETAIL DESCRIPTION: FLASHLOC SFM TRIM KIT REVISION DATE: 2/2/2021 3/8" x 7/8" HHCS BOLT 3/8 TRI DRIVE NUT O TRIM CAP (2V") DRAWING NOT TO SCALE ALL DIMENSIONS ARE Mo NOMINAL Q PRODUCT PROTECTED BY U- ONE OR MORE US PATENTS LEGAL NOTICE SHEET BLUE RAVEN SOLAR DRAWING NUMBER: ss