593263846_1702E120 YEL-2616315
1630816302
16309 16323
16320
16319
16314
16236
16235
1622916223
16303
16228
10728
10732
10804
10808
16219
16215
VANCIL CT SE
VA
N
C
I
L
R
D
S
E
PALOUSE AVE SE
558969-147677
15 kVA (C)
Y705 (25T)
558959-147729
25 kVA (C)
558970-147676
558959-147704
25 kVA (C)
558939-147676
Y1807 (40T)
558908-147675
25 kVA (B)
558945-147664
37.5 kVA (B)
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
59
3
2
6
3
8
4
6
Owner / Developer Contact Info
officeATTN:
PSE
2711 Pacific Ave SE
Olympia WA, 98503
Vincent Messina 360-480-4706
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
JOB SITE
PROJECT
LOCATION
OVERHEAD CIRCUIT MAP
SCALE: 6"= 1 MILE
Vicinity Map
HP Svc/MSA
HP Main
Distribution
Job Order
Temporary
Removal
Relocation
Perm. Service
Superior
ORDER#NOTIF#
PWR
PROJECT PHASE
N/AN/A
N/AN/A
N/AN/A
N/AN/A
N/AN/A
N/A
N/AN/A
N/AN/A
59326384612069857
CABLE TV
PHONE
GAS
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
REV#DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
04/17/25
04/17/25
D.Shamp 253-904-7409 04/17/25
N/A YELM
1702E120 YEL-26
AVIAN PROTECTION AND RMV OH XF
16215 PALOUSE AVE SE, YELM WA, 98597
PSE
593263846
AS NOTED 01/01
THURSTON QSTHLE
SE 30-17N-02E
1702E120 N/A 1702E120 YEL-26
N
PSE Locates Req'd
Developer Locates Req'd No
No
Yes
YesFlagging Req'd
Outages Req'd
AU
D
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:
V.Messina 360-480-4706
V.Messina 360-480-4706
Vincent.Messina@pse.com
360-480-4706
Vincent MessinaRemoved at site:
Grid Number:
kVA Rating:
Foreman to redline the following information
TRANSFORMER REMOVAL
Company ID#:
Primary phase connected to:
Tested Secondary Voltage
P03
558908-147675
25kVA
SITE PLAN
SCALE: 1" = 100'
POWER GENERAL NOTES
1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation
from this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foreman's
Copy.
2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to
commencing work to get the underground facilities located.
4.All work is to be done in accordance with local municipal and county permit requirements as applicable.
5.Inclement weather conditions may cause delays in construction times and dates.
#4
A
C
S
R
(
B
Ø
)
26
YE
L
SITE SPECIFIC NOTES
P01 GRID# 558969-147677
-EX 45' POLE TO REMIAN
-REPLACE (2) LB C/O's FOR SWITCH FUSED AT 25T (9999108, 3412400)
-REPLACE (1) LB C/O FOR XF FUSED AT 6T (9999108, 3412100)
-INST BUSHING COVER (9996101)
-INST (3) LB C/O COVER (9999530)
-INST (6) COVERED JUMPERS (9998076)
P02 GRID# 558939-147676
-EX 45' POLE TO REMIAN
-REPLACE LB C/O FOR SWITCH FUSED AT 40T (9999108, 3412500)
-INST LB C/O COVER (9999530)
-INST (2) COVERED JUMPERS (9998076)
-WRAP EXPOSED GROUND WIRE ON TERM ARM
P03 GRID# 558908-147675
-EX 45' POLE TO REMIAN
-RMV 25kVA 120/240V OH XF
-RMV LB C/O AND BRACKET
UNITS OF PROPERTY -
INSTALL ONLY
MATERIAL QTY
DIST. ARRESTERS
DIST. CUTOUTS 4
DIST. INSULATORS
TRANS. ARRESTERS
TRANS. INSULATORS
UNITS OF PROPERTY -
REMOVAL ONLY
MATERIAL QTY
DIST. ARRESTERS
DIST. CUTOUTS 5
DIST. INSULATORS
TRANS. ARRESTERS
TRANS. INSULATORS
CROSSARMS