10732 Palisades St SE.- Construction PlanScale
Date
Drawn By
Checked By
Project Number
Varies
SITE PLAN
No.Description Date
CSL DESIGNS
Csldesigns21@gmail.com
CATHERINE
REMODEL
10732 PALISADES ST. SE
YELM, WA 98597
A001
CS
GM
4/1/2025
-
SITE PLAN N
WHFUR
W/D
T
KITCHEN
PATIO
LIVING
ROOMFP
DINING
ROOM
BEDROOM
ABEDROOM
B
BEDROOM
C
BEDROOM
D
GARAGE
PANTRY
CLOSET
CLOSET CLOSET
CLOSET
C
C
WALK-IN
CLOSET
BATH
A
BATH
B
BATH
C
CL
O
S
E
T
SD
SD
SD
SD
EGRESS
EGRESS
EGRESS
EG
R
E
S
S
FRAMING SPECIFICATIONS
FRAMING LUMBER SHALL BE S-DRY, KD, OR WC-19, AND GRADED AND MARKED IN
CONFORMANCE WITH WCLIB STANDARD "GRADING RULES FOR WEST COAST LUMBER NO.
17", OR WWPA STANDARD, "WESTERN LUMBER GRADING RULES 2011". FURNISH TO THE
FOLLOWING MINIMUM STANDARDS:
JOISTS AND BEAMS (2X & 3X MEMBERS) HEM-FIR NO. 2
MINIIMUM BASE VALUE, FB - 850PSI
(4X MEMBERS) DOUGLAS FIR-LARCH NO. 1
MINIIMUM BASE VALUE, FB - 1000PSI
STUDS & MISC. FRAMING DOUGLAS FIR-LARCH OR HEM-FIR
NO. 2
PLATES DOUGLAS FIR-LARCH
WOOD FASTENERS
A.NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING
SPECIFICATIONS:
SIZE LENGTH DIAMETER
8D 2- 1/2" 0.131"
16D 3-1/2" 0.135"
IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT
NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION )
FOR REVIEW.
NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE
DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTER SINKING PERMITTED.
TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGRESS WITH THE MEMBER AND
STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END.
B.ALL BOLTS IN WOOD SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE
HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS SHALL CONFORM TO THE NATIONAL
DESIGN SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60
TO 70 PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8"
AND SMALLER LAG SCREWS.
WOOD FRAMING NOTES--THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE
PLANS:
A.ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO
THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC
"TIMBER CONSTRUCTION MANUAL" AND THE AF&PA "NATIONAL DESIGN
SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING UNLESS OTHERWISE
NOTED, SHALL CONFORM TO IRC TABLE R602.3.(1). COORDINATE THE SIZE AND
LOCATION OF ALL OPENINGS WITH ARCHITECTURAL DRAWINGS.
B.WALL FRAMING : REFER TO ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL
WALLS. ALL STUDS SHALL BE SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHALL
BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND
AT BEAM OR HEADER BEARING LOCATIONS. TWO 2X8 HEADERS SHALL BE PROVIDED
OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD
COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE
CONTINUOUS SOLID BLOCKING AT MID-HEIGHT OF ALL STUD WALLS OVER 10'-0" IN
HEIGHT.
ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END
NAIL TOP PLATE TO EACH STUD WITH 16D NAILS. AND TOENAIL OR END NAIL EACH
STUD TO BOTTOM PLATE WITH 16D NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16D
@12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16D NAILS @4" O.C.
EACH SIDE JOINT.
ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD
FRAMING BELOW WITH TWO ROWS OF 16D NAILS @ 12" ON-CENTER, OR ATTACHED
TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR BOLTS @ 4'-0" ON-CENTER
EMBEDDED 7" MINIMUM, UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF
BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16D @12"
ON-CENTER. UNLESS OTHERWISE NOTED, GYPSUM WALLBOARD SHALL BE FASTENED
TO THE INTERIOR SURFACE OF ALL STUDS AND PLATES WITH NO. 6 X 1-1/4" TYPE S OR
W SCREWS @ 8" ON-CENTER. UNLESS INDICATED OTHERWISE, 1/2" (NOMINAL) APA
RATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO ALL EXTERIOR
SURFACES WITH 8D NAILS @ 6" ON-CENTER AT PANEL EDGES AND TOP AND BOTTOM
PLATES (BLOCK UN-SUPPORTED EDGES) AND TO ALL INTERMEDIATE STUDS AND
BLOCKING WITH 8D NAILS @ 12" ON-CENTER ALLOW 1/8" SPACING AT ALL PANEL
EDGES AND PANEL ENDS.
BORED OR DRILLED HOLES:
MAY NOT EXCEED 60% OF STUD WIDTH (IF DRILLED OVER 40% MUST
BE DOUBLED)
SHALL NOT BE CLOSER THAN 5/8" TO EDGE OF STUD
SHALL NOT BE IN THE SAME SECTION AS A CUT OR NOTCH
(EXCEPTIONS R602.6; DETAILS: FIGURES R602.6(1),R602.6.2(2),R602.6.1
FIREBLOCKING:
IN CONCEALED SPACES OF STUD WALLS & PARTITIONS AS FOLLOWS:
1.VERTICALLY AT CEILINGS AND WALLS
2.HORIZONTALLY AT MAX. 10' INTERVALS
3.ALL INTERCONNECTIONS SUCH AS SOFFITS, DROP CEILINGS,
COVE CEILINGS.
4.IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT TOP &
BOTTOM OF RUN
5.OPENINGS AROUND VENTS/PIPES/DUCTS AT FLOOR AND
CEILING LEVELS
FIRE BLOCKING MATERIALS SHALL BE CONSISTENT WITH R302.11.1
LOOSE FILL MATERIAL IS NOT ALLOWED
NOTE: ALL FIRE BLOCKS AND DRAFT BLOCKS REQUIRED TO BE
INSTALLED PRIOR TO FRAMING INSPECTION.
DOOR HANDLES:
OPERABLE PARTS OF DOOR HANDLES, PULLS, LATCHES, LOCKS AND
OTHER DEVICES INSTALLED IN ADULT FAMILY HOMES SHALL BE
OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT
GRASPING, PINCHING OR TWISTING OF THE WRIST. POCKET DOORS
SHALL HAVE GRASPABLE HARDWARE AVAILABLE WHEN IN THE
CLOSED OR OPEN POSITION.
LEVEL I - FLOOR PLAN - EXISTING
SCALE: 1/4"=1'-0"1 N
FINISHED ATTIC - FLOOR PLAN - EXISTING
SCALE: 1/4"=1'-0"1 N
Scale
Date
Drawn By
Checked By
Project Number
Varies
A002
CS
-
GM
No.Description Date
CSL DESIGNS
Csldesigns21@gmail.com
CATHERINE
REMODEL
10732 PALISADES ST. SE
YELM, WA 98597
EXISTING PLANS &
SPECIFICATIONS
4/1/2025
WHFUR
LAUNDRY
T
KITCHEN
PATIO
LIVING
ROOMFP DINING
ROOM
BEDROOM
ABEDROOM
B
BEDROOM
C
BEDROOM
D
GARAGE
PANTRY
CLOSET
CLOSET CLOSET
CLOSET
C
C
STORAGE
BATH
A
BATH
B
BATH
C
CL
O
S
E
T
SD
SD
SD
SD
EGRESS
EGRESS
EGRESS
EG
R
E
S
S
LEVEL I - FLOOR PLAN - PROPOSED
SCALE: 1/4"=1'-0"1 N
BEDROOM
E
(E)58''x58" Egress
window
@37" Sill height
SD 2SDCO
LANDING RAMP LANDING
Concrete ramp w/ broom
finish for slip resistance
12x12x16 Concrete footer. install 4x4
P.T. post connected to 12x12x16
concrete footer by manufactured
connectors installed in accordance with
section R507.(TYP.)
spacing less
than 4"
SECTION SIDE VIEW
LANDING
36" MIN H Railing
Simpson ABA44Z post base
(TYP.) drill 4" into conc. w/(1) 1
2"
conc. anchor
4x4 P.T. Post
2x4 P.T. Stringer
12x12x16" Footer
(TYP. ALL)
LANDING
B NTS
RAMP SLOPE TO MAINTAIN 8.3%
GRADIENT OR LOWER. RAMP
VERTICAL HEIGHT=24"
HORIZONTAL LENGTH = 35'-0"
ALL RAILING MATERIALS SHALL BE
PRESSURE TREATED WOOD Ramp require continuous
handrails on both sides
SCOPE OF WORK:
ENCLOSE EXISTING DINING ROOM FOR USE AS A BEDROOM.
CONSTRUCT RAMP. RAMP IS LESS THAN 30" ABOVE GROUND.
REMOVE BATHROOM B BATHTUB AND INSTALL A WALK IN SHOWER.
1.
2.
APPLICABLE CODES:
2021 INTERNATIONAL BUILDING CODE - WA STATE
AMENDMENT
2021 INTERNATIONAL RESIDENTIAL CODE
RCW 19.27 STATE BUILDING CODE
CONSTRUCTION NOTES:
EXISTING DUCTWORK AND GRILLE TO REMAIN TO PROVIDE
HEATING TO BEDROOM.
INSTALL NEW SMOKE DETECTORS.
PROVIDE COMBINED FIRE AND SMOKE DETECTOR. INSTALL A
MINIMUM OF 3 FEET AWAY FROM BATHROOM DOOR.
1.
2.
3.
1.
2.
3.
4.
GENERAL NOTES:
ALL SMOKE ALARMS TO BE INTERCONNECTED,
HARDWIRED WITH A BATTERY BACK-UP. ALL CARBON
MONOXIDE ALARMS TO BE INTERCONNECTED,
HARDWIRED WITH A BATTERY BACK-UP. ALARMS SHALL
BE INSTALLED IN SUCH A MANNER SO THAT THE
DETECTION DEVICE WARNING IS AUDIBLE FROM ALL
AREAS OF THE DWELLING UPON ACTIVATION OF A
SINGLE ALARM. PER IRC R330.5, R314 and R315.
INTERIOR NON-LOAD BEARING WALLS DO NOT REQUIRE
STRUCTURAL HEADER.
PROVIDE INSULATION FOR ALL HOT WATER PIPING WITH
A MINIMUM THERMAL RESISTANCE (R-VALUE) OF R-3.
REFERENCE BORED OR DRILLED HOLES & FIRE
BLOCKING NOTATIONS ON SHEET A002.
FIRE BLOCKING IS REQUIRED FOR ALL OPENINGS
AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES TO
RESIST PASSAGE OF FLAMES AND COMBUSTION.
FRAME WALLS, INSTALL DOORS, WINDOWS PER
ELEVATION DETAILS ON SHEET A001, A004 AND PER
FRAMING SPECIFICATIONS ON SHEET A002.
EXPOSED WALL CAVITIES SHALL BE INSULATED TO R-15
FOR 2x4 AND R-21 FOR 2x6.
5.
6.
7.
T
NOT IN SCOPE
(E)PROGRAMMABLE THERMOSTAT
(E) WALLS
(N) WALLS
LEGEND:
WH (E)WATER HEATER
FUR (E) FURNACE
C CLOSET
CO CARBON MONOXIDE SENSOR
SD SMOKE DETECTOR
E EXISTING
N NEW
W/D WASHER/DRYER
3.
A
B
1
INTERIOR WALL ASSEMBLY DETAIL
1/2" Gypsum
wall board
2x4 STUD @ 16" O.C.
1/2" Gypsum
wall board
D1 3'x6'-8", INTERIOR GRADE DOOR
DOOR SCHEDULE
D1
Scale
Date
Drawn By
Checked By
Project Number
Varies
A003
PROPOSED PLAN
CS
-
4/1/2025
GM
No.Description Date
CSL DESIGNS
Csldesigns21@gmail.com
CATHERINE
REMODEL
10732 PALISADES ST. SE
YELM, WA 98597