Loading...
10732 Palisades St SE.- Construction PlanScale Date Drawn By Checked By Project Number Varies SITE PLAN No.Description Date CSL DESIGNS Csldesigns21@gmail.com CATHERINE REMODEL 10732 PALISADES ST. SE YELM, WA 98597 A001 CS GM 4/1/2025 - SITE PLAN N WHFUR W/D T KITCHEN PATIO LIVING ROOMFP DINING ROOM BEDROOM ABEDROOM B BEDROOM C BEDROOM D GARAGE PANTRY CLOSET CLOSET CLOSET CLOSET C C WALK-IN CLOSET BATH A BATH B BATH C CL O S E T SD SD SD SD EGRESS EGRESS EGRESS EG R E S S FRAMING SPECIFICATIONS FRAMING LUMBER SHALL BE S-DRY, KD, OR WC-19, AND GRADED AND MARKED IN CONFORMANCE WITH WCLIB STANDARD "GRADING RULES FOR WEST COAST LUMBER NO. 17", OR WWPA STANDARD, "WESTERN LUMBER GRADING RULES 2011". FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS AND BEAMS (2X & 3X MEMBERS) HEM-FIR NO. 2 MINIIMUM BASE VALUE, FB - 850PSI (4X MEMBERS) DOUGLAS FIR-LARCH NO. 1 MINIIMUM BASE VALUE, FB - 1000PSI STUDS & MISC. FRAMING DOUGLAS FIR-LARCH OR HEM-FIR NO. 2 PLATES DOUGLAS FIR-LARCH WOOD FASTENERS A.NAIL SIZES SPECIFIED ON DRAWINGS ARE BASED ON THE FOLLOWING SPECIFICATIONS: SIZE LENGTH DIAMETER 8D 2- 1/2" 0.131" 16D 3-1/2" 0.135" IF CONTRACTOR PROPOSES THE USE OF ALTERNATE NAILS, THEY SHALL SUBMIT NAIL SPECIFICATIONS TO THE STRUCTURAL ENGINEER (PRIOR TO CONSTRUCTION ) FOR REVIEW. NAILS - PLYWOOD (APA RATED SHEATHING) FASTENERS TO FRAMING SHALL BE DRIVEN FLUSH TO FACE OF SHEATHING WITH NO COUNTER SINKING PERMITTED. TOE-NAILS SHALL BE DRIVEN AT AN ANGLE OF 30 DEGRESS WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END. B.ALL BOLTS IN WOOD SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS AND NUTS OF ALL BOLTS AND LAG BOLTS SHALL CONFORM TO THE NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION WITH A LEAD BORE HOLE OF 60 TO 70 PERCENT OF THE SHANK DIAMETER. LEAD HOLES ARE NOT REQUIRED FOR 3/8" AND SMALLER LAG SCREWS. WOOD FRAMING NOTES--THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS: A.ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO THE MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE, THE AITC "TIMBER CONSTRUCTION MANUAL" AND THE AF&PA "NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION". MINIMUM NAILING UNLESS OTHERWISE NOTED, SHALL CONFORM TO IRC TABLE R602.3.(1). COORDINATE THE SIZE AND LOCATION OF ALL OPENINGS WITH ARCHITECTURAL DRAWINGS. B.WALL FRAMING : REFER TO ARCHITECTURAL DRAWINGS FOR THE SIZE OF ALL WALLS. ALL STUDS SHALL BE SPACED AT 16" O.C. UNO. TWO STUDS MINIMUM SHALL BE PROVIDED AT THE END OF ALL WALLS AND AT EACH SIDE OF ALL OPENINGS, AND AT BEAM OR HEADER BEARING LOCATIONS. TWO 2X8 HEADERS SHALL BE PROVIDED OVER ALL OPENINGS NOT OTHERWISE NOTED. SOLID BLOCKING FOR WOOD COLUMNS SHALL BE PROVIDED THROUGH FLOORS TO SUPPORTS BELOW. PROVIDE CONTINUOUS SOLID BLOCKING AT MID-HEIGHT OF ALL STUD WALLS OVER 10'-0" IN HEIGHT. ALL WALLS SHALL HAVE A SINGLE BOTTOM PLATE AND A DOUBLE TOP PLATE. END NAIL TOP PLATE TO EACH STUD WITH 16D NAILS. AND TOENAIL OR END NAIL EACH STUD TO BOTTOM PLATE WITH 16D NAILS. FACE NAIL DOUBLE TOP PLATE WITH 16D @12" O.C. AND LAP MINIMUM 4'-0" AT JOINTS AND PROVIDE EIGHT 16D NAILS @4" O.C. EACH SIDE JOINT. ALL STUD WALLS SHALL HAVE THEIR LOWER WOOD PLATES ATTACHED TO WOOD FRAMING BELOW WITH TWO ROWS OF 16D NAILS @ 12" ON-CENTER, OR ATTACHED TO CONCRETE BELOW WITH 5/8" DIAMETER ANCHOR BOLTS @ 4'-0" ON-CENTER EMBEDDED 7" MINIMUM, UNLESS INDICATED OTHERWISE. INDIVIDUAL MEMBERS OF BUILT-UP POSTS SHALL BE NAILED TO EACH OTHER WITH TWO ROWS OF 16D @12" ON-CENTER. UNLESS OTHERWISE NOTED, GYPSUM WALLBOARD SHALL BE FASTENED TO THE INTERIOR SURFACE OF ALL STUDS AND PLATES WITH NO. 6 X 1-1/4" TYPE S OR W SCREWS @ 8" ON-CENTER. UNLESS INDICATED OTHERWISE, 1/2" (NOMINAL) APA RATED SHEATHING (SPAN RATING 24/0) SHALL BE NAILED TO ALL EXTERIOR SURFACES WITH 8D NAILS @ 6" ON-CENTER AT PANEL EDGES AND TOP AND BOTTOM PLATES (BLOCK UN-SUPPORTED EDGES) AND TO ALL INTERMEDIATE STUDS AND BLOCKING WITH 8D NAILS @ 12" ON-CENTER ALLOW 1/8" SPACING AT ALL PANEL EDGES AND PANEL ENDS. BORED OR DRILLED HOLES: MAY NOT EXCEED 60% OF STUD WIDTH (IF DRILLED OVER 40% MUST BE DOUBLED) SHALL NOT BE CLOSER THAN 5/8" TO EDGE OF STUD SHALL NOT BE IN THE SAME SECTION AS A CUT OR NOTCH (EXCEPTIONS R602.6; DETAILS: FIGURES R602.6(1),R602.6.2(2),R602.6.1 FIREBLOCKING: IN CONCEALED SPACES OF STUD WALLS & PARTITIONS AS FOLLOWS: 1.VERTICALLY AT CEILINGS AND WALLS 2.HORIZONTALLY AT MAX. 10' INTERVALS 3.ALL INTERCONNECTIONS SUCH AS SOFFITS, DROP CEILINGS, COVE CEILINGS. 4.IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT TOP & BOTTOM OF RUN 5.OPENINGS AROUND VENTS/PIPES/DUCTS AT FLOOR AND CEILING LEVELS FIRE BLOCKING MATERIALS SHALL BE CONSISTENT WITH R302.11.1 LOOSE FILL MATERIAL IS NOT ALLOWED NOTE: ALL FIRE BLOCKS AND DRAFT BLOCKS REQUIRED TO BE INSTALLED PRIOR TO FRAMING INSPECTION. DOOR HANDLES: OPERABLE PARTS OF DOOR HANDLES, PULLS, LATCHES, LOCKS AND OTHER DEVICES INSTALLED IN ADULT FAMILY HOMES SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING OR TWISTING OF THE WRIST. POCKET DOORS SHALL HAVE GRASPABLE HARDWARE AVAILABLE WHEN IN THE CLOSED OR OPEN POSITION. LEVEL I - FLOOR PLAN - EXISTING SCALE: 1/4"=1'-0"1 N FINISHED ATTIC - FLOOR PLAN - EXISTING SCALE: 1/4"=1'-0"1 N Scale Date Drawn By Checked By Project Number Varies A002 CS - GM No.Description Date CSL DESIGNS Csldesigns21@gmail.com CATHERINE REMODEL 10732 PALISADES ST. SE YELM, WA 98597 EXISTING PLANS & SPECIFICATIONS 4/1/2025 WHFUR LAUNDRY T KITCHEN PATIO LIVING ROOMFP DINING ROOM BEDROOM ABEDROOM B BEDROOM C BEDROOM D GARAGE PANTRY CLOSET CLOSET CLOSET CLOSET C C STORAGE BATH A BATH B BATH C CL O S E T SD SD SD SD EGRESS EGRESS EGRESS EG R E S S LEVEL I - FLOOR PLAN - PROPOSED SCALE: 1/4"=1'-0"1 N BEDROOM E (E)58''x58" Egress window @37" Sill height SD 2SDCO LANDING RAMP LANDING Concrete ramp w/ broom finish for slip resistance 12x12x16 Concrete footer. install 4x4 P.T. post connected to 12x12x16 concrete footer by manufactured connectors installed in accordance with section R507.(TYP.) spacing less than 4" SECTION SIDE VIEW LANDING 36" MIN H Railing Simpson ABA44Z post base (TYP.) drill 4" into conc. w/(1) 1 2" conc. anchor 4x4 P.T. Post 2x4 P.T. Stringer 12x12x16" Footer (TYP. ALL) LANDING B NTS RAMP SLOPE TO MAINTAIN 8.3% GRADIENT OR LOWER. RAMP VERTICAL HEIGHT=24" HORIZONTAL LENGTH = 35'-0" ALL RAILING MATERIALS SHALL BE PRESSURE TREATED WOOD Ramp require continuous handrails on both sides SCOPE OF WORK: ENCLOSE EXISTING DINING ROOM FOR USE AS A BEDROOM. CONSTRUCT RAMP. RAMP IS LESS THAN 30" ABOVE GROUND. REMOVE BATHROOM B BATHTUB AND INSTALL A WALK IN SHOWER. 1. 2. APPLICABLE CODES: 2021 INTERNATIONAL BUILDING CODE - WA STATE AMENDMENT 2021 INTERNATIONAL RESIDENTIAL CODE RCW 19.27 STATE BUILDING CODE CONSTRUCTION NOTES: EXISTING DUCTWORK AND GRILLE TO REMAIN TO PROVIDE HEATING TO BEDROOM. INSTALL NEW SMOKE DETECTORS. PROVIDE COMBINED FIRE AND SMOKE DETECTOR. INSTALL A MINIMUM OF 3 FEET AWAY FROM BATHROOM DOOR. 1. 2. 3. 1. 2. 3. 4. GENERAL NOTES: ALL SMOKE ALARMS TO BE INTERCONNECTED, HARDWIRED WITH A BATTERY BACK-UP. ALL CARBON MONOXIDE ALARMS TO BE INTERCONNECTED, HARDWIRED WITH A BATTERY BACK-UP. ALARMS SHALL BE INSTALLED IN SUCH A MANNER SO THAT THE DETECTION DEVICE WARNING IS AUDIBLE FROM ALL AREAS OF THE DWELLING UPON ACTIVATION OF A SINGLE ALARM. PER IRC R330.5, R314 and R315. INTERIOR NON-LOAD BEARING WALLS DO NOT REQUIRE STRUCTURAL HEADER. PROVIDE INSULATION FOR ALL HOT WATER PIPING WITH A MINIMUM THERMAL RESISTANCE (R-VALUE) OF R-3. REFERENCE BORED OR DRILLED HOLES & FIRE BLOCKING NOTATIONS ON SHEET A002. FIRE BLOCKING IS REQUIRED FOR ALL OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES TO RESIST PASSAGE OF FLAMES AND COMBUSTION. FRAME WALLS, INSTALL DOORS, WINDOWS PER ELEVATION DETAILS ON SHEET A001, A004 AND PER FRAMING SPECIFICATIONS ON SHEET A002. EXPOSED WALL CAVITIES SHALL BE INSULATED TO R-15 FOR 2x4 AND R-21 FOR 2x6. 5. 6. 7. T NOT IN SCOPE (E)PROGRAMMABLE THERMOSTAT (E) WALLS (N) WALLS LEGEND: WH (E)WATER HEATER FUR (E) FURNACE C CLOSET CO CARBON MONOXIDE SENSOR SD SMOKE DETECTOR E EXISTING N NEW W/D WASHER/DRYER 3. A B 1 INTERIOR WALL ASSEMBLY DETAIL 1/2" Gypsum wall board 2x4 STUD @ 16" O.C. 1/2" Gypsum wall board D1 3'x6'-8", INTERIOR GRADE DOOR DOOR SCHEDULE D1 Scale Date Drawn By Checked By Project Number Varies A003 PROPOSED PLAN CS - 4/1/2025 GM No.Description Date CSL DESIGNS Csldesigns21@gmail.com CATHERINE REMODEL 10732 PALISADES ST. SE YELM, WA 98597