Loading...
JJYelm,WA050225UNCONCENTRATED AREA: 376 S.F. / 15 STANDING AREA: 13 S.F. / 7 STORAGE AREAS: 529 S.F. / 500 KITCHEN AREAS: 668 S.F. / 100 RESTROOM AND CIRCULATION AREA: TOTAL OCCUPANCY 26 2 2 7 1 38 FE FE FE XXX XXXXXX X-X X XX X A-3 X X X X-X XX-X X XX ROOM NAME (TOP) AND ROOM NUMBER (BOTTOM) INTERIOR / EXTERIOR ELEVATION ELEVATION NO. (TOP), SHEET NO. (BOTTOM) DETAIL REFERENCE - DETAIL NO. (TOP), SHEET NO. (BOTTOM) SECTION - SECTION NO. (TOP), SHEET NO. (BOTTOM) KEYED NOTE - SEE KEYED NOTES DOOR NUMBER WALL TYPE & DECOR DETAIL NO. (TOP), SHEET NO. (BOTTOM) FLOOR FINISHES CEILING FINISHES EQUIPMENT REFERENCE - SEE EQUIPMENT COORDINATION SCHEDULE SHEET A-4 ARCHITECTURAL JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON PROJECT TEAM ABBREVIATIONS: AC. A.D.A. ANSI. ADD. A-BOLT A.B.C. A/C ADD'N A.F.C. A.F.F. A.F.G. AGG. ALT. ALUM. AMP. ARCH. ASP. AVG. BD. BLDG. BLKG. BM. B.M. B.O. BOT. CAB'T. C.B. CEM. CER. C.F. C.F.M. C.I.P. CG. CHAN. C.J. C.L. CLG. CLR. CM. C.M.U. C.O. COL. CONC. CONN. CONST. CONT. CONTR. COR'G. C.T. CTR. CTSK. C.V. C.W. C.W.P. Ø DB. DBL. D.C. ° DET. DIAG. DIM. DISP. DL. DN. D.P. D.S. DWG. DWL. E.C. E.D.F. E.F. E.I.F.S. E.J. EL. ELEV. EMP. ENG. EQ. EQUIP. EXH. EXIST. EXP. EXT. F.A. F.A.C.P. F.C.O. FT. FIN. FIXT. FL. FLR. F.D. F.F. FLUOR. FTG. FND. ACOUSTIC AMERICANS with DISABILITIES ACT AMERICAN NATIONAL STANDARDS INSTITUTE ADDENDUM ANCHOR BOLT AGGREGATE BASE COURSE AIR CONDITIONING ADDITION ABOVE FINISHED CEILING ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AGGREGATE ALTERNATE ALUMINUM AMPER, AMPS ARCHITECT ASPHALT AVERAGE BOARD BUILDING BLOCKING BEAM BENCHMARK BOTTOM OF BOTTOM CABINET CATCH BASIN CEMENT CERAMIC CUBIC FEET CUBIC FEET PER MINUTE CAST IN PLACE CORNERGUARD CHANNEL CONTROL JOINT CONSTRUCTION JOINT CENTER LINE CEILING CLEAR CENTIMETER CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CONTRACTOR CORRUGATED CERAMIC TILE COUNTER COUNTERSUNK CHECK VALVE COLD WATER COLD WATER PIPE DIAMETER DECIBEL DOUBLE DIRECT CURRENT DEGREE DETAIL DIAGONAL DIMENSION DISPENSER DEADLOAD DOWN DAMP PROOFING DOWNSPOUT DRAWING DOWEL ELECTRICAL CONTRACTOR ELECTRIC DRINKING FOUNTAIN EXHAUST FAN EXTERIOR INSULATING FINISHING SYSTEM EXPANSION JOINT ELECTRIC ELEVATION EMPLOYEE ENGINEER EQUAL EQUIPMENT EXHAUST EXISTING EXPANSION EXTERIOR FIRE ALARM FIRE ALARM CONTROL PANEL FLOOR CLEANOUT FEET FINISH FIXTURE FLASHING FLOOR FIRE DAMPER, FLOOR DRAIN FINISHED FLOOR FLUORESCENT FOOTING FOUNDATION FR. F.R.P. F.H.C. GA. GALV. G.C. GD. G.I. GL. GND. GRL. GYP. H.B. H.D.A.S. HDN. HDW. HDWD. H.M. HORIZ. H.P. H.R. HTR. HT. H.V.A.C. H.W. I.D. IN. INSUL. INT. INV. JAN. J-BOX JT. JST. k K.P. kV kVA kW kWH LAM. LAV. lb. LDG. L.F. LG. L.L. L.L.H. L.L.V. LOC. LONG. LT. LTH. LVR. L.W.C. M. MAT'L. MAX. M.C.J. MECH. MFR. M.H. MIN. M.L. MLDG. M.O. M.R. M.SW. MTD. MTL. MULL. N/A N.G. N.I.C. N.L. NOM. N.T.S. No. O.A. OBS. O.C. O.D. O.F.S. O.F.D. OSHA OPNG. FRAME FIBERGLASS REINF. PANEL FIRE HOSE CAB. GAUGE GALVANIZED GENERAL CONTRACTOR GRADE GALVANIZED IRON GLASS GROUND GRILLE GYPSUM HOSE BIB HEADED ANCHOR STUDS HARDENER HARDWARE HARDWOOD HOLLOW METAL HORIZONTAL HIGH POINT HANDRAIL HEATER HEIGHT HEATING, VENTILATING, AND AIR CONDITIONING HOT WATER INSIDE DIAMETER INCH INSULATION INTERIOR INVERT JANITOR JUNCTION BOX JOINT JOIST KIPS (1000 lbs.) KICK PLATE KILOVOLT KILOVOLT-AMPS KILOWATT KILOWATT-HOUR LAMINATED LAVATORY POUNDS LANDING LINEAR FEET LENGTH LIVE LOAD LONG LEG HORIZONTAL LONG LEG VERTICAL LOCATION LONGITUDINAL LIGHT LATH LOUVER LIGHT WEIGHT CONCRETE METER MATERIAL MAXIMUM MASONRY CONTROL JOINT MECHANICAL MANUFACTURER MAN HOLE, METAL HALIDE MINIMUM METAL LATH MOULDING MASONRY OPENING MOISTURE RESISTANT MAIN SWITCHBOARD MOUNTED METAL MULLION NOT APPLICABLE NATURAL GRADE NOT IN CONTRACT NIGHT LIGHT NOMINAL NOT TO SCALE NUMBER OVERALL OBSERVE ON CENTER OUTSIDE DIAMETER OVERFLOW SCUPPER OVERFLOW DRAIN OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION OPENING d PERP. Ø P.C. PG. P.I.V. P.L. PL. PLBG. PLYWD. PNL. P.R. P.S.I. P.S.F. PTD. PTN. PT. P.V.C. QTY. r. R.A. R.C.P. RD. R.D. REG. REINF. REQ'D. REV. RFG. RGH. RM. R.T.U. S.C. S.C.J. SCR. SECT. SEL. S.F. SHT. SDG. SIM. SLDG. SM. S.O.V. SPEC. SPL. SQ. S.S. S.T.C. STD. STL. STRUC. SUSP. SW.BD. SYM. T.C. T.G. THRU T.O. T.S.D. TSTAT. TYP. U.L. U.N.O. U.P.S. V. VA. VERT. V.G. VEST. V.C.T. V.C.P. V.T.R. W.B. W.C. W.C.O. WD. WDW. W.F. W.H. W/ W/O W.O. W.P. W.W. W.W.F. W.W.M. W.L. XFMR. PENNY PERPENDICULAR PHASE PRECAST PAGE POST INDICATOR VALVE PROPERTY LINE PLATE PLUMBING PLYWOOD PANEL PAIR POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT PAINTED PARTITION POINT POLY VINYL CHLORIDE QUANTITY RADIUS RETURN AIR REFLECTED CEILING PLAN ROUND ROOF DRAIN REGISTER REINFORCED, REINFORCING REQUIRED REVISION ROOFING ROUGH ROOM ROOF TOP UNIT SITE CONTRACTOR STUCCO CONTROL JOINT SCREW SECTION SELECT SQUARE FEET SHEET SIDING SIMILAR SLIDING SMOOTH SHUT OFF VALVE SPECIFICATION SPLASH SQUARE STAINLESS STEEL SOUND TRANSMISSION CLASS STANDARD STEEL STRUCTURE SUSPENDED SWITCHBOARD SYMETRICAL TOP OF CURB TEMPERED GLASS THROUGH TOP OF TOP OF STEEL DECK THERMOSTAT TYPICAL UNDERWRITERS LABORATORIES UNLESS NOTED OTHERWISE UNINTERRUPTIBLE POWER SUPPLY VENT VOLT-AMPERE VERTICAL VERTICAL GRAIN VESTIBULE VINYL COMP. TILE VITREOUS CLAY PIPE VENT THROUGH ROOF WATER BASE WATER CLOSET WALL CLEANOUT WOOD WINDOW WIDE FLANGE WATER HATER WITH WITHOUT WALL OPENING WEATHER PROOF WINDOW WALL WELDED WIRE FABRIC WELDED WIRE MESH WIND LOAD TRANSFORMER VICINITY MAP: CORPORATE: JIMMY JOHN'S 2202 FOX DRIVE CHAMPAIGN, ILLINOIS 61820 PHONE FAX EMAIL CONTACT 217.356.9900 217.359.2956 construction@jimmyjohns.com - FRANCHISEE: SHEET INDEX: MECHANICAL: PRECISION ENGINEERING GROUP, LLC 5800 E. SKELLY DRIVE, SUITE 1100 TULSA, OK 74135 PHONE FAX EMAIL CONTACT 918.749.3000 918.749.3003 - - ELECTRICAL: PRECISION ENGINEERING GROUP, LLC 5800 E. SKELLY DRIVE, SUITE 1100 TULSA, OK 74135 PHONE FAX EMAIL CONTACT 918.749.3000 918.749.3003 - - PROJECT INFORMATION: CONTRACTOR: - TBD - - PHONE FAX EMAIL CONTACT - - - - ARCHITECT: BAYUS DESIGN WORKS 1901 COMMONWEALTH COURT, SUITE A LOUISVILLE, KY 40299 PHONE FAX EMAIL CONTACT 502.426.8020 502.426.0527 sean@bayusdesign.com Sean McDonnell SYMBOL LEGEND: PROJECT ADDRESS PROJECT DESCRIPTION INTERIOR FIT-UP ( SPRINKLED) OCCUPANCY TYPE OCCUPANT LOAD 38 OCCUPANCY CALCULATIONSOCCUPANCY LOAD PLAN EXITS CONSTRUCTION TYPE V-B (SHELL) REQUIRED: 1 / PROVIDED: 1 DESIGN CODES TENANT LEASABLE SQ. FOOTAGE 1,844 SQ. FT. TENANT USABLE SQ. FOOTAGE 1,726 SQ. FT. B BUILDING / STRUCTURAL PLUMBING ELECTRICAL MECHANICAL FIRE/LIFE SAFETY FUEL/GAS ENERGY ACCESSIBILITY 1010 EAST YELM AVE. SUITE H YELM, WA 98957 T-1 TITLE SHEET TENANT IMPROVEMENT / YELM, WA 98957 03-25-25 TITLE SHEET SPECIFICATIONS FLOOR PLAN AND DETAILS FRAMING PLAN AND DETAILS REFLECTED CEILING PLAN AND DETAILS FLOOR FINISH PLAN AND SCHEDULE EQUIPMENT PLAN AND EQUIPMENT SCHEDULE INTERIOR ELEVATIONS INTERIOR ELEVATIONS CABINET DETAILS T-1 SP-1 A-1 A-1.1 A-2 A-3 A-4 A-6 A-7 A-8 A-9 A-10 A-5 MECHANICAL MECHANICAL PLAN MECHANICAL NOTES AND SCHEDULE PLUMBING PLUMBING PLANS PLUMBING DETAILS AND SCHEDULES PLUMBING ISONOMETRICS MECH, ELEC, PLUMB GENERAL NOTES ELECTRICAL ELECTRICAL POWER PLAN ELECTRICAL LIGHTING PLAN ELECTRICAL PANELS SCHEDULES COMMUNICATIONS / DATA COMMUNICATIONS / DATA PLAN M-1 M-2 P-1.1 P-2 P-3 MEP-1 E-1 E-2 E-3 COM-1 HEAT LOAD CALCULATIONSM-3 MECH, ELEC, PLUMB SPECIFICATIONSMEP-2 (NOT USED) ENERGY CALCULATIONS ENERGY CALCULATIONSEC-1 RESTROOM PLAN AND ELEVATIONS 217.493.9499 - adam@evergreensubs.com Adam Teske ADAM TESKE 1010 E. YELM AVE. YELM, WA 98597 PHONE FAX EMAIL CONTACT ENERGY CALCULATIONSEC-2 ALT. WALK-IN SPECIFICATIONSMEP-3 GAS PLUMBING PLANSP-1.2 2021 INTERNATIONAL BUILDING CODE 2021 UNIFORM PLUMBING CODE 2021 NATIONAL ELECTRICAL CODE 2021 MECHANICAL CODE 2021 INTERNATIONAL FIRE CODE 2021 FUEL GAS CODE 2021 WASHINGTON ENERGY CODE ACCESSIBILITY CODE, (2009 A117.1) EXTERIOR ELEVATIONS DRIVE THRU DETAILSA-11 DRIVE THRU PLANA-12 JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON SP-1 SPECIFICATIONS S P E C I F I C A T I O N S JJ PROTOTYPE 11.04.19 PROVIDE WRITTEN GUARANTEES FOR A PERIOD OF ONE (1) YEAR FROM THE DATE OF INSTRUCTIONS AND GUARANTEES FOR ALL EQUIPMENT AND MATERIALS INSTALLED. INSPECTION. UPON INSPECTION, PROVIDE WRITTEN OPERATION AND MAINTENANCE 26. OF THE WORK OR DAMAGE TO THE ITEMS. REPLACE DAMAGED OR UNFIT MATERIALS, STORED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS TO AVOID DISRUPTION 25. ACCORDANCE WITH THE MOST CURRENT WRITTEN MANUFACTURER'S INSTRUCTIONS. COMPLY WITH MANUFACTURER'S INSTRUCTIONS, PERFORM THE WORK IN STRICT 24. THROUGHOUT THE PROJECT OR THEY SHALL BE REJECTED. THAT ARE SIMILAR SHALL BE THE SAME TYPE, MODEL AND STYLE FOR THE SAME USE IT IS SPECIFICALLY DESIGNED OR SPECIFIED. ALL MATERIALS AND EQUIPMENT 23. 22. UNAUTHORIZED PERSONNEL UNTIL ACCEPTANCE BY OWNER. PROPERTY FROM THEFT AND VANDALISM AND THE PREMISES FROM ENTRY BY PROTECT THE WORK, STORED PRODUCTS, CONSTRUCTION EQUIPMENT AND OWNER'S 21. CONTRACTOR HAS USED PRODUCTS INCORRECTLY LABELED BY THE MANUFACTURER OR OWNER AND REIMBURSE ALL THE COSTS OF THE TESTING TO THE OWNER, UNLESS THE CONTRACTOR SHALL CORRECT THE DEFICIENCY AT NO ADDITIONAL COST TO THE GENERALLY ACCEPTED TRADE STANDARDS OR THE PROJECT REQUIREMENTS, THE AT THE OWNER'S COST. IF THE REQUESTED TEST SHOW NON-CONFORMANCE TO THE PROJECT REQUIREMENTS, THE CONTRACTOR SHALL ENLIST A TESTING LABORATORY 20. REPLACE DAMAGED SURFACE AND MATERIALS OF THE PREVIOUSLY INSTALLED WORK BY 19. ACCESSORIES, EQUIPMENT AND FIXTURES INSTALL REQUIRED BLOCKING AT NO 18. ALL WORK BY SKILLED MECHANICS IN ACCORDANCE WITH ESTABLISHED STANDARDS OF THE HIGHEST QUALITY FINISHED PRODUCT, EXPRESSED OR IMPLIED. PERFORM 17. CONDITIONS, THE ONE HAVING THE MOST STRINGENT REQUIREMENTS SHALL GOVERN, CASE OF CONFLICT BETWEEN THE PROJECT REQUIREMENTS AND/OR EXISTING EXISTING CONDITIONS PRIOR TO CONSTRUCTION, FABRICATION, OR PURCHASING. IN 16. OWNER TO MINIMIZE CONFLICT AND FACILITATE THE OWNER'S OPERATION. DURING THE FINAL STAGE OF CONSTRUCTION. COORDINATE AND COOPERATE WITH THE 15. MATERIALS SHALL BE LEFT IN ONE LOCATION UPON OWNER'S REPRESENTATIVE'S B. ONE FULL BOX OF EACH CERAMIC FLOOR TILE FREE FROM NICKS, SCRATCHES OR CRACKS. A. ONE FULL GALLON OF EACH PAINT COLOR IN A CLEAN, TIGHTLY CLOSED CAN, FROM THE SAME MATERIAL, LOT OR RUN USED TO CONSTRUCT AND FINISH THE 14. ITEMS SHALL OPERATE SMOOTHLY WITHOUT STICKING OR BINDING AND WITHOUT F. ALL JOINTS SHALL BE TIGHT, STRAIGHT, EVEN AND SMOOTH. ALL OPERABLE FINAL ACCEPTANCE OF THE WORK. AT NO COST TO THE OWNER. HAS MADE PREVIOUSLY APPROVED CHANGES. OTHER TRADES, INSTALLERS AND SUBCONTRACTORS. ADDITIONAL COST TO THE CONTRACT. WORKMANSHIP IN EACH OF THE VARIOUS TRADES. AS APPROVED BY JIMMY JOHN'S. DIRECTION AND APPROVAL. C. ONE-HALF BAG OF TILE GROUT. AND CLEARLY MARKED. EXCESSIVE "PLAY" OR LOOSENESS. PROJECT: CHROMATE PRIMER IN MANNER TO OBTAIN NOT LESS THAN 1.0 MIL DRY FILM MATERIALS, PROVIDE CONTACT SURFACES WITH COATING OF AN IMPROVED ZINC 16. WHERE ALUMINUM ITEMS ARE TO BE ERECTED AND IN CONTACT WITH DISSIMILAR THICKNESS. E. ALL CORNERS AND EDGES SHALL BE STRAIGHT AND TRUE WITHOUT DENTS, D. WALL AND SOFFIT INTERSECTIONS SHALL BE 90° OR THE EXACT ANGLE C. ALL HORIZONTAL SURFACES SHALL BE LEVEL OR CONSTRUCTED TO THE EXACT MEASURED BY A STRAIGHT EDGE PLACED ANYWHERE ON THE SURFACE HORIZONTAL SURFACES SHALL NOT BE GREATER THAN 1/8" IN 10'-0" AS B. THE MAXIMUM DEVIATION FROM THE TRUE PLANE FOR VERTICAL AND A. ALL VERTICAL SURFACES SHALL BE PLUMB OR CONSTRUCTED TO THE EXACT 13. WAVES OR BULGES OR OTHER BLEMISHES. INDICATED OR INTENDED. ANGLE INDICATED OR INTENDED. SLOPES OR ANGLES INDICATED. FOLLOWING TOLERANCES SHALL APPLY TO ALL WORK: B. REPAIR OR REPLACEMENT OF PROPERTY DAMAGED DURING FINAL COMPLETION OF A. POWER VACUUMING THE ENTIRE SPACE. MATERIALS, UNLESS REQUESTED BY THE OWNER. CLEAN-UP SHALL BE INCLUDED AND NOT THE PREMISES NEAT, CLEAN AND CLEAR OF TOOLS, EQUIPMENT AND SURPLUS 27. THE PROJECT. BE LIMITED TO: THAT DOORS OPEN FREELY WITHOUT BINDING, AND WHEN CLOSED, WILL LATCH OF DOORS AS SPECIFIED WITH 3/32" CLEARANCE AT MEETING EDGES. DEMONSTRATE FOR CARPETING AND MAKE NO JOBSITE FIT IN CUTS UNLESS APPROVED. HANG PAIRS FOR "UNDERCUTS" OR OTHER DEVIATIONS IN FIT. VERIFY CLEARANCES REQUIRED CLEARANCE AT TOPS AND 3/8" CLEARANCE AT BOTTOM, UNLESS SPECIFICALLY NOTED 11. MANUFACTURER AND CONFIRM TYPE, LOCATION, AND SPECIAL REQUIREMENTS OF HARDWARE FOR EACH DOOR PRIOR TO CUTTING. PROPERLY. 10. 9. SHIMS BEFORE FASTENING. LEAVE READY TO RECEIVE SEALANT WHERE INDICATED ON CONSTRUCTION OF ADJACENT WALLS. ADJUST FRAME LOCATIONS AS NECESSARY USING FASTENINGS: ANCHOR TO ADJOINING WALLS WITH SPECIFIED ANCHORS. BRACE FLOOR ANCHORS TO FLOOR CONSTRUCTION WITH APPROVED TYPE MECHANICAL RIGID, PLUMB, LEVEL AND TRUE. ALIGN WITH ADJACENT CONSTRUCTION. SECURE 8. COAT TO ALL EXPOSED SURFACES. LEAVE READY TO RECEIVE FINISH PAINTING. AND IMPERFECTIONS. APPLY UNIFORM COAT OF MANUFACTURER'S STANDARD PRIME 7. REQUIRED FOR A SECURE INSTALLATION AND SHALL BE IN ACCORDANCE WITH TRADE 6. INDICATED ON DRAWINGS; FABRICATE UNITS SQUARE, TRUE AND FREE FROM DEFECTS. 5. PRACTICE AND MANUFACTURER'S WRITTEN RECOMMENDATIONS FOR THE USE INTENDED. QUALITY WORKMANSHIP AND MATERIALS. PROVIDE IN ACCORDANCE WITH BEST TRADE 4. SEAMLESS CONSTRUCTION WITH NO VISIBLE SEAMS OR JOINTS ON FACES OR VERTICAL 3. 2. FREE FROM SCALE AND PITTING AND OTHER SURFACE DEFECTS, UNLESS OTHERWISE 1. 3. JOINTS AND VOIDS SOLID. SUPERFICIAL POINTING WITH THE SKIM BEAD WILL NOT SEALANT OVER BACKING TO UNIFORM THICKNESS IN CONTINUOUS BEADS FILLING ALL FRAMES TO RETAIN POSITION AND CONTINUOUSLY CHECK ALIGNMENT DURING REQUIREMENTS FOR THE SPECIFIED HARDWARE AND INTENDED USE. THE DRAWINGS. DRAWINGS. EDGES; THICKNESSES AS SCHEDULED ON DRAWINGS. D. MINIMUM 16. GA. FOR INTERIOR FRAMES. C. MINIMUM 22 GA. FOR FACE STIFFENERS. B. 16 GA. FOR EDGE CHANNELS. A. MINIMUM 18. GA. FOR FACE SHEETS OF INTERIOR DOORS. DIVISION 8 - WOOD AND HOLLOW METAL DOORS AND FRAMES MANUFACTURER'S WRITTEN INSTRUCTIONS PRIOR TO INSTALLATION. FOLLOWING MATERIAL BE ACCEPTED. NOTED. AND CURTAIN WALLS. 9. ADJUST SUPPORTS, SPANS OR OTHERWISE FOR INSTALLATION WITHIN SPECIFIED APPLICABLE ASTM STANDARDS AS REFERENCED ABOVE, USING A LASER LEVEL. AS INDICATED. TRUE TO LINE, LEVEL AND PLUM, AND IN ACCORDANCE WITH 8. BLOCKING, BRACING, AND ANCHOR STRIPS. LEAVE READY TO RECEIVE FINISH SECURE TO TRACK. INSTALL HEAD TRACK IN ACCORDANCE WITH DETAILS. INSTALL WITH ASTM STANDARDS. ERECT STUDS ON 16" CENTERS AND 7. 6. BETWEEN LINTELS AND HEADERS IN TOP TRACKS. 5. 4. HEMMED EDGES. HOT DIPPED FINISH WHERE NOTED. 3. 2. 20 GAUGE PROVIDE 16 GAUGE AT DOOR JAMBS AND AT STOREFRONT. ASTM C645-00, HOT DIPPED FINISH WHERE EXPOSED TO MOISTURE NOT LESS THAN 1. 2. PROVIDE PRIMER AS RECOMMENDED BY SEALANT MANUFACTURER FOR THE SPECIFIC JOINTS AT INTERSECTIONS BETWEEN PLANES. AROUND DOOR AND WINDOW FRAMES RUBBER SEALING COMPOUND WITH MINIMUM 90% SOLIDS. USE AT ALL INTERIOR ACOUSTICAL SEALANT WHICH SHALL BE NON-HARDENING, NON-DRYING SYNTHETIC CONDITIONS AND SUBSTRATES. SPECIFICATIONS TTS-1543 OR FS TT-S 230 TYPE "II", CLASS "A". PROVIDE 1. DIVISION 7 - SEALANTS AND CAULKING/ ROOF PATCHING MATERIALS. TOLERANCES. EQUIPMENT, INCLUDING DOOR STOPS. METAL SUPPORT SYSTEM (WALL STUDS) DIVISION 9 - FINISHES 4. 2. PROVIDE TYPE "X" FIRE RETARDANT GYPSUM WALL BOARD PANELS 5/8" THICK, TESTED IN LOCATIONS AS RECOMMENDED BY INDUSTRY STANDARDS AND IN COMPLIANCE WITH 5. FOR CONTROL JOINTS, PROVIDE U.S. GYPSUM #093 OR APPROVED EQUAL. INSTALL RATING, TAPERED AND ROUNDED EDGES AND BE INSTALLED IN ALL WET AREAS AS 4. WATER RESISTANT GYPSUM WALL BOARD SHALL BE 5/8" THICK, QUALIFIED FOR 1- HOUR 3. PROVIDE METAL EDGE AND CORNER BEADS AT ENDS, EDGES AND CORNERS. AND QUALIFIED FOR 1-HOUR RATING, TAPERED AND ROUNDED AT EDGES AS INDICATED 1. PROVIDE GYPSUM WALL PANELS MANUFACTURED IN ACCORDANCE WITH REQUIREMENTS OF EGGSHELL FOR ALL INTERIOR FINISHES. SUPPLEMENTED HEREINAFTER AND UPON WRITTEN OWNER APPROVAL. IN GENERAL, USE 13. FINISH INTERIOR SURFACES, AS SCHEDULED ON DRAWINGS, EXCEPT AS MODIFIED AND 12. OTHER PAINT MANUFACTURER'S MAY NOT BE SUBSTITUTED WITHOUT APPROVAL OF SURFACES IN GOOD AND CLEAN CONDITION. PROVIDE FOR MULTIPLE SITE VISITS AS 11. AT COMPLETION, TOUCH-UP AND RESTORE FINISH WHERE DAMAGED AND LEAVE ALL HOLES, CRACKS AND OTHER IMPERFECTIONS WITH PUTTY AND SAND SMOOTH. OF TRIM, PRIME BARE WOOD SCHEDULED TO RECEIVE PAINT FINISH; FINISH NAIL OR PUTTY. IF STAIN HAS BEEN USED, TINT CRACK FILLER TO MATCH; PRIME BACKS AFTER STAIN COAT HAS BEEN APPLIED, FILL CRACKS AND HOLES WITH PLASTIC WOOD READY FOR APPLICATION. SANDPAPER SURFACES OF TRIM SMOOTH AND WIPE CLEAN. THOROUGHLY CLEAN SURFACES AND APPLY NO FINISH UNLESS SURFACES ARE DRY AND 10. BACK PRIME ALL EXTERIOR AND INTERIOR WOOD AND TRIM PRIOR TO INSTALLATION. COLOR. SAND ALL WOODWORK BETWEEN COATS TO A SMOOTH SURFACE. SURFACE IMPERFECTIONS WITH PUTTY TINTED WITH PRIMER OR STAIN TO MATCH WOOD PRIMING COAT HAS BEEN APPLIED, THOROUGHLY FILL ALL NAIL HOLES AND OTHER 9. SANDPAPER ALL NEW WOOD TO SMOOTH AND EVEN SURFACE AND DUST OFF. AFTER PAINTING PRIOR TO APPLICATION OF PAINT. PROVIDE VENTILATORS AS REQUIRED TO 8. ALL SURFACES TO BE PAINTED SHALL BE THOROUGHLY CLEANED AND PREPARED FOR CONTRACTOR SHALL FOLLOW MANUFACTURER'S INSTRUCTIONS FOR PROPER APPLICATION MANUFACTURER FOR THE MATERIAL TO WHICH THEY WILL BE APPLIED. PAINTING 7. PAINT TYPES USED SHALL BE THOSE SPECIFICALLY RECOMMENDED BY THE GYPSUM WALL BOARD INDICATED ON DRAWINGS. REQUIRED FOR TOUCH-UP AND REFINISHING. U.S. GYPSUM STANDARDS. ON DRAWINGS. ARCHITECT. ASTM C36/C36M-01. PREVENT BUILD-UP OF FUMES. OF THE PAINT. ALIGN ALL JOINTS AND CORNERS. REPLACE DAMAGED TILE AT NO ADDITIONAL COST TO OWNER. AREA CLOSED UNTIL TILE IS FIRMLY SET. PROTECT FLOORING FROM DAMAGE. 9. CLOSE AREAS IN WHICH TILE IS BEING PLACED TO TRAFFIC AND OTHER WORK. KEEP APPLICABLE. VARY MORTAR THICKNESS, AS NECESSARY, TO ACCOMMODATE VARIATION OF WORK. CUT TILE AT WALL INTERSECTIONS FOR CONCEALMENT BY BASE WHERE BY OWNER. VERIFY LAYOUT AND CUTS WITH PROJECT MANAGER PRIOR TO COMMENCEMENT BUTTED JOINTS, TO PATTERN INDICATED IN THE DRAWINGS, OR AS SPECIFIED 8. INSTALL TILE TO CONCRETE SUBSTRATE PER TCA STANDARD F113-89 WITH TIGHTLY OLD SEALANTS OR GLAZING COMPOUNDS AND PROTECTIVE COATINGS. METAL SHALL BE MATTER AND CONTAMINANTS SUCH AS GREASE, OIL, DUST, WATER, SURFACE DIRT, 7. CLEAN METAL AND WOOD SURFACES AND CONCRETE FLOORS, REMOVING ALL FOREIGN 4. STOREFRONT GLASS SHALL BE AS REQUIRED FOR THE SIZES AND CONDITIONS 3. GENERAL GLASS SHALL BE q3 IN ACCORDANCE WITH FEDERAL SPECIFICATIONS DD-G- 2. ALL GLASS EDGES SHALL BE GROUND SMOOTH AND POLISHED. THICK, UNLESS OTHERWISE NOTED. ALL GLASS TO BE CLEAR GLASS. 1. PROVIDE TEMPERED GLASS, GRAD "B", STYLE #1, TYPE "1", QUALITY 03, 1/2" USING MATERIALS RECOMMENDED FOR THAT PURPOSE BY THE MANUFACTURER. SURFACES, IN ACCORDANCE WITH THE TIMING RECOMMENDED BY THE MANUFACTURER, 5. UPON COMPLETION, IMMEDIATELY REMOVE ALL SURPLUS ADHESIVE FROM ADJACENT 4. CAREFULLY INSPECT ALL SURFACES TO RECEIVE BASE PRIOR TO INSTALLATION. 3. USE ADHESIVES ONLY AS RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL TO CONDITIONS. 2. PROVIDE JOB MITERED INSIDE AND OUTSIDE CORNERS PER DRAWING DETAILS FOR ALL 1. INSTALL TILE BASE IN TOILETS AS SCHEDULED. VERIFY WITH HEALTH CODE REQUIREMENTS. 12. DAMP CURE PER MORTAR AND GROUT MANUFACTURER'S RECOMMENDATIONS. 11. GROUT FLUSH WITH TILE EDGES. WIPE TILES WITH CHEESE CLOTH INSTEAD OF WITH DOW CORNING 795 SILICONE BUILDING SEALANT. BEADS AT 6" ON CENTER 10. INSTALL TILE TO WOOD SURFACES AND ALUMINUM GLAZING CHANNEL AND METAL BASE 15. UPON COMPLETION, REMOVE ALL EXCESS SEALANT AND MATERIALS FROM SURFACES; SHALL BE LEVEL, FLUSH SQUARE PLUMB AND IN ALIGNMENT WITH OTHER WORK. 14. SET ALL EXTRUSIONS IN CORRECT LOCATIONS AS SHOWN IN THE DETAILS. THEY REQUIRED TO POSITION AGAINST FIXED STOPS AND FRAME BARS. SIDES, INDOORS AND OUT, IN ACCORDANCE WITH FGMA RECOMMENDATIONS. SHIM AS 13. CENTER GLASS IN RABBETS AND POSITION SO AS TO MAINTAIN CLEARANCES ON ALL ARE CLEAN, DRY AND READY TO RECEIVE GLAZING MATERIALS. REMOVE ALL CLEARANCES ARE SUFFICIENT TO PREVENT "POINT LOADING", AND THAT SURFACES 12. VERIFY THAT FRAMES TO RECEIVE GLAZING ARE SQUARE AND TRUE, THAT PERIMETER 11. INSTALL IN ACCORDANCE WITH FGMA RECOMMENDATIONS UNLESS NOTED OTHERWISE. 10. ALL EDGES, DRILLED HOLES AND NOTCHES SHALL BE FACTORY CUT AND/OR FACTORY GLASS SHALL HAVE A 1/4" VERTICAL CLEAR SPACE BETWEEN GLASS PANELS. USE ONLY IF REQUIRED BY LOCAL BUILDING CODES, OTHERWISE ALL STOREFRONT 9. USE SILICONE SEALANT DOW #795 OR GE SILPRUF, CLEAR, OR APPROVED EQUAL. 8. PROVIDE NON-SHRINKING ELASTROMERIC TAPER WHERE REQUIRED. 7. PROVIDE STANDARD PREFORMED GLAZING TAPE, STANLOCKE 400, TRIMCO 440, OR 6. PROVIDE CLIPS ON NON-CORROSIVE METAL WITH ROUNDED EDGES DESIGNED FOR RESILIENT ACCESSORIES DESIGNED FOR POSITIONING GLASS IN RABBETS. 5. PROVIDE RESILIENT NEOPRENE BLOCKS 70 TO 90 SHORE A DUROMETER HARDNESS AND SHALL BE FACTORY MILL FINISH. REFER TO ELEVATION PLAN FOR TYPE OF FINISH DETAILED FRAME SECTION SHALL BE EXPOSED WHERE INDICATED. FRAME FINISH CONTACT BLOCKS, NOT GLASS. WASH AND CLEAN ALL GLASS FRAMING MEMBERS. PROTECTIVE COATING FROM FRAMING SURFACES. FORMED, TOUCH-UP "RAW" EDGES TO MATCH FRAME. APPROVED. COLOR. CLEANED BY MECHANICAL OR SOLVENT PROCEDURES. 451 AND FGMA GLAZING MANUAL. REPAIR DAMAGED SURFACES PRIOR TO INSTALLATION. GLASS AND GLAZING WHICH IT IS APPLIED. BASE IN THE TILE THICKNESS. MAXIMUM. SPONGE. 10. PROVIDE FINAL FINISH THAT IS SMOOTH, WITHOUT DIVOTS, BUMPS, BOWS OR ANY ANGLES. FIRE TAPE PENETRATIONS AT DEMISING WALLS, CORRIDOR ENVELOPE AND FILLING AND TAPER FLUSH WITH SURFACE; NO SECOND COAT REQUIRED AT INTERIOR COAT. AFTER TAPING AND EMBEDDING COMPOUND IS DRY, APPLY SECOND COAT APPLY EMBEDDING COMPOUND REINFORCING TAPE CENTERED OVER JOINT; APPLY SKIM 9. APPLY PRE-FILL COMPOUND TO JOINT IN ACCORDANCE WITH INDUSTRY STANDARDS. SULFIDE SEALANT; WHERE UNEXPOSED, PROVIDE ACOUSTIC SEALANT. PROTRUSIONS THROUGH WALL BOARD. WHERE SEALANT IS EXPOSED, PROVIDE POLY- ADJACENT CONSTRUCTION, INCLUDING AROUND FRAMED OPENINGS AND OTHER 8. APPLY CONTINUOUS BEAD OF SEALANT AT ALL JOINTS OF WALL BOARD ABUTTING CONSTRUCTION INCLUDING ACCESS DOORS AND PANELS. METHODS REQUIRED FOR SATISFACTORY COMPLETION OF GYPSUM WALL BOARD 7. PROVIDE ALL INCIDENTAL AND ACCESSORY MATERIALS, TOOLS, EQUIPMENT, AND BOARD TO METAL FRAMING, AND TYPE 'S' PAN HEAD SCREWS FOR ATTACHMENT OF INDICATED, PROVIDE TYPE 'S' BUGLE HEAD SCREWS FOR ATTACHMENT OF WALL 6. PROVIDE FASTENERS IN ACCORDANCE WITH ASTM C1002-01; UNLESS OTHERWISE NOTED OR 6. SET AND GROUT TILE WHEN AMBIENT TEMPERATURE IS AT LEAST 50 AND RISING. TO DETERMINE THE REQUIRED EXTENT OF SUBFLOOR PREPARATION. 4. DO NOT COMMENCE INSTALLATION UNTIL SUBSTRATE HAS BEEN MADE SUITABLE FOR 3. ALL INSTALLATION SHALL CONFORM TO THE LATEST APPLICABLE TILE COUNCIL OF 2. INSTALLERS MUST BE SPECIALISTS WITH A MINIMUM OF TWO (2) YEARS EXPERIENCE. BY MANUFACTURER AND IN ACCORDANCE WITH INDUSTRY STANDARDS. FRAMING TO DOOR FRAMES. OTHER RATED ASSEMBLIES. OTHER SURFACE BLEMISH, READY TO RECEIVE PAINT. AMERICA AND ANSI STANDARDS. 1. INSTALL TILE IN AREAS INDICATED . USE ADHESIVES AND APPLY ONLY AS RECOMMENDED TILE INSTALLATION. TILE 5. PROVIDE "OWENS CORNING" SOUND ATTENUATION BATT INSULATION AT ALL PERIMETER WALLS OR TOILET ROOMS FULL HEIGHT OF WALLS. INSULATION SHALL BE 3 1/2" THICK FRICTION FIT INSTALLATION FOR 16" STUD SPACING. CUT AS REQUIRED FOR UTILITIES IN WALLS. 11. IN ADDTION TO OTHER STIPULATED REQUIREMENTS FOR CLEANING, COMPLETELY REMOVE FINGER PRINTS AND TRACES OF SOIL FROM THE SURFACES OF EXPOSED PORTIONS, USING ONLY THOSE CLEANING MATERIALS RECOMMENDED FOR THE PURPOSE BY THE MANUFACTURER OF THE MATERIAL BEING CLEANED. TOLERANCE OF 1 IN 1000. SUSPENDED CEILING SYSTEM 1. PROVIDE HOLD DOWN CLIPS WITH UL CLASSIFICATION LABEL. 2. WORK INCLUDED: PROVIDE SUSPENDED CEILING SYSTEM WHERE SHOWN ON THE DRAWINGS. 3. USE ADEQUATE NUMBERS OF SKILLED WORKMEN WHO ARE THOROUGHLY TRAINED AND 4. DO NOT BEGIN INSTALLATION IN ANY AREA UNTIL SUFFICIENT MATERIALS ARE ON THE 5. PROVIDE THE MANUFACTURER'S HEAVY DUTY SUSPENSION SYSTEM, COMPLYING WITH 6. PROVIDE OTHER MATERIALS, NOT SPECIFICALLY DESCRIBED BUT REQUIRED FOR A COMPLETE 7. EXAMINE THE AREA AND CONDITIONS UNDER WHICH WORK OF THIS SECTION WILL BE 8. EXCEPT AS MODIFIED BY REQUIREMENTS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION, 9. PROVIDE LATERAL BRACING AS REQUIRED BY PERTINENT CODES AND REGULATIONS. SECURE 10. MAKE ALL FINISHED SURFACES LEVEL, OR TRUE TO PLANE WHERE PLANE IS DESIGNED TO REQUIREMENTS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION, AND AS APPROVED AND PROPER INSTALLATION, AS SELECTED BY THE CONTRACTOR SUBJECT TO THE APPROVAL PERFORMED CORRECT CONDITIONS ARE DETRIMENTAL TO TIMELY AND PROPER COMPLETION OF THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED. INSTALLATION RECOMMENDATIONS AS APPROVED BY THE ARCHITECT. INSTALL THE WORK OF THIS SECTION IN STRICT ACCORDANCE WITH THE MANUFACTURER'S LATERAL BRACING TO STRUCTURAL MEMBERS. SECURE AT RIGHT ANGLES TO THE DIRECTION OF THE PARTITION AND FOUR-WAYS IN LARGE CEILING AREAS. BE OTHER THAN LEVEL, WITHIN A TOLERANNCE OF 1 IN 1000, AND STRAIGHT WITHIN A INSTALLATION, AS SELECTED OF THE ARCHITECT. BY THE ARCHITECT. AS SPECIFIED HEREIN, AND AS NEEDED FOR A COMPLETE AND PROPER INSTALLATION. EXPERIENCED IN THE NECESSARY CRAFTS AND WHO ARE COMPLETELY FAMILIAR WITH THE SPECIFIED REQUIREMENTS AND THE METHODS NEEDED FOR PROPER PERFORMANCE JOBSITE TO COMPLETE THE WORK OF THIS SECTION IN THAT AREA. OF THE WORK OF THIS SECTION. SUSPENSION SYSTEM - AS REQUIRED TO SUPPORT GYPSUM BOARD PANELS, FIXTURES AND 12. MATERIALS OTHER COMPONENTS AS INDICATED, INCLUDING ANCHORAGES, HANGERS, RUNNERS, CROSS RUNNERS, SPLINES, CLIPS, MOLDING, FASTENERS AND OTHER MEMBERS, DEVICES AND ACCESSORIES. COMPLY WITH ASTM C635. 2' X 4' GRID/2'X2' GRID. ENAMEL EDGE MOLDING - METAL CHANNEL TYPE WITH SINGLE FLANGE EXPOSED. HUNG OR INDIRECT FROM DUCTS, PIPES OR CONDUIT. EXPOSED FINISH - WHITE BAKED HANGER WIRE - NOT LESS THAN 12 GAUGE (0.106") GALVANIZED STEEL. TYPE - DIRECT GRID SYSTEM "USG" TYPE DX 15/16" EDGE. CEILING PANELS - 2' x 4' VINYL CLAD GYPSUM CEILING TILE(PREP AND RESTROOMS) 1. FIBER REINFORCED PANELS (FRP) CORRODE. PROVIDE ALL TRIM AND ACCESSORIES AS REQUIRED FOR A COMPLETE THAN 25. ALL PANELS SHALL BE MOISTURE RESISTANT AND SHALL NOT RUST OR INSTALLATION AS INDICATED AND SPECIFIED HEREIN. COLOR OF PANELS, TRIM AND ACCESSORIES SHALL BE WHITE. 2. PREFINISHED PANEL AS SCHEDULED. 3. 4. WITH V-NOTCH SPREADER. MITER CUT MOLDINGS AND TRIM PIECES AT CORNERS AND INTERSECTIONS AS REQUIRED TO PROVIDE SMOOTH TRANSITION. 5. IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS AND LEFT FREE FROM DEFECTS, COMPONENTS THAT ARE DAMAGED OR IMPROPERLY INSTALLED SHALL BE REMOVED AND REPLACED WITHOUT ADDITIONAL COST TO THE OWNER. 2. UPON COMPLETION OF PAINT APPLICATION CAREFULLY REMOVE STENCIL FROM 1. OWNER TO SUPPLY STENCIL FOR SUPER SEAL LOGO. CONTRACTOR TO COORDINATE EXACT PLACEMENT OF LOGO WITH DRAWINGS AND JIMMY JOHN'S CONSTRUCTION MANAGER PRIOR TO APPLICATION. CONTRACTOR TO APPLY STENCIL TO BRICK SURFACE TAKING CARE TO PRESS FIRMLY INTO ANY JOINTS OR TEXTURE SO AS NOT TO ALLOW FOR ANY OVERSPRAY BEHIND STENCIL DURING PAINT APPLICATION. ONCE STENCIL HAS BEEN PLACED CONTRACTOR SHALL APPLY PAINT TO EXTENT INDICATED ON DRAWINGS, 3. IN AN EFFORT TO PROVIDE AN AGED APPEARANCE, CONTRACTOR SHALL WIRE BRUSH ENTIRE SUPER SEAL LOGO BEING CAREFUL NOT TO COMPLETELY REMOVE NEWLY PAINTED FINISH. CONTRACTOR MUST NOTIFY JIMMY JOHN'S CONSTRUCTION MANAGER ONE WEEK PRIOR TO THIS FINAL STEP TO INSURE PROPER APPEARANCE. PAINTING - SPECIALTY (EXTERIOR SUPER SEAL) USING SPRAY EQUIPMENT. THE FOLLOWING MATERIALS SHALL BE LEFT AT JOBSITE. THEY SHALL BE TAKEN THE OWNER OR THE OWNER'S SUBCONTRACTORS MAY OCCUPY PORTIONS OF THE PROJECT ALL DIMENSIONS AND FINISHES SHALL BE VERIFIED AND COORDINATED WITH ALLOWABLE TOLERANCES - UNLESS OTHERWISE NOTED OR INDICATED. THE PERFORM ALL WORK IN ACCORDANCE WITH ACCEPTABLE TRADE PRACTICE TO INSURE COORDINATE BLOCKING REQUIREMENTS WITH ADJACENT OR RELATED TRADES, REPAIR PROPERTY DAMAGE BY THE INSTALLERS TO A LIKE NEW CONDITION OR WHERE REQUESTED BY THE OWNER TO CERTIFY CONFORMANCE TO TRADE STANDARDS OR PROVIDE SECURITY OF THE WORK, INCLUDING TOOLS AND UNINSTALLED MATERIALS. MAINTAIN AN ACTIVE FIRE EXTINGUISHER AT THE PROJECT. DO NOT USE MATERIAL OR EQUIPMENT FOR ANY PURPOSE OTHER THAN THAT FOR WHICH WHEN THE PROJECT REQUIREMENTS REQUIRE THAT THE INSTALLATION OF WORK SHALL ALL PRODUCTS AND EQUIPMENT SHALL BE DELIVERED IN UNDAMAGED CONDITION AND NOTIFY THE OWNER WHEN THE WORK IS SUBSTANTIALLY COMPLETE AND READY FOR PROVIDE FINAL CLEAN-UP AND DAMAGE REPAIR AT THE PROJECT CONCLUSION. LEAVE PROVIDE NON-SAG SEALANT COMPLYING WITH REQUIREMENTS OF FEDERAL AND SOUND ATTENUATION BATT INSULATION SOUND ATTENUATION BATT INSULATION: ALL SURFACES SHALL BE ADEQUATELY CLEANED AND PREPARED IN ACCORDANCE WITH PROVIDE BACKING MATERIAL BY DOW "ETHAFOAM" OR APPROVED EQUAL. APPLY PROVIDE HOLLOW METAL DOOR AS REQUIRED ON PLANS CONSTRUCTED WITH THE PROVIDE WELDED METAL DOOR FRAMES AT ALL DOORS, AS DETAILED PROVIDE CUSTOM MADE WELDED UNITS WITH INTEGRAL TRIM; SIZES AND SHAPES AS FACE STIFFENERS, EDGES AND HARDWARE REINFORCEMENT SHALL BE THE HIGHEST PROVIDE DOORS OF SIZES AND TYPES INDICATED ON DRAWINGS, FULLY WELDED INSTALL FRAMES IN ACCURATE LOCATIONS AS INDICATED ON DRAWINGS. INSTALL AFTER FABRICATION, DRESS, FILL AND SAND EXPOSED SURFACES, BODY-PUTTY HOLES HARDWARE REINFORCEMENT AND ANCHORS (ERECTION, FLOOR AND JAMB) SHALL BE AS PREPARE DOORS FOR FINISH HARDWARE. OBTAIN TEMPLATES FROM HARDWARE INSTALL WOOD DOORS, FRAMES, AND TRIM. SIZES AND THICKNESS AS SCHEDULED ON HANG DOORS AS SCHEDULED ON DRAWINGS, IN ACCURATE LOCATIONS WITH 1/8" PROVIDE CHANNEL-SHAPED ROLL FORMED SHEET STEEL MEMBERS CONFORMING WITH PROVIDE BLOCKING AND FRAMING FOR ALL WALL MOUNTED FINISH HARDWARE AND PROVIDE JACK STUDS BETWEEN BOTTOM TRACK AND WINDOW AND/OR RELIEF SILLS INTERIOR WALL CONNECTIONS TO EXIST. STRUCTURE ABOVE REFER TO DRAWINGS. PROVIDE ROLL HAT-SHAPED CHANNELS MINIMUM 20 GAUGE, 7/8" DEEP WITH 1/2" PROVIDE COLD, ROLLED STEEL CHANNELS NOT LESS THAN 16 GAUGE. PROVIDE KICK AS SHOWN FOR WALL STUDS,CEILING MEMBER, DRAFT OR SMOKE STOPS ERECT ALL COMPONENTS FOR CEILING AND SOFFIT FRAMING IN ACCURATE LOCATIONS SET FLOOR TRACKS IN ACCURATE LOCATIONS AND SECURELY ANCHOR IN ACCORDANCE ALL PANELS SHALL HAVE A CLASS 1 FLAME - SPREAD CLASSIFICATION INDEX OF LESS FOLLOW MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES FOR ALL PANELS SHALL BE INSTALLED IN A VERTICAL POSITION IN FULL LENGTH UNITS. APPLY RECOMMENDED ADHESIVE TO BACK OF PANEL TO PROVIDE 100% COVERAGE UPON COMPLETION OF WORK, SURFACES OF PANELS AND COMPONENTS SHALL BE CLEANED 1. SQUARE FOOT CALCULATIONS AS NOTED ON THE TITLE SHEET. CONTRACT WILL INCLUDE CONSTRUCTING WALLS AND CEILINGS FINISHES, DETAILS & SPECIFICATIONS. SECURE AND PAY FOR GOVERNMENT FEES, LICENSES AND PERMITS. FOOTAGES. NOTIFY THE OWNER AND ARCHITECT OF COMPLIANCE OR DISCREPANCIES, COMPARING THOSE DISCREPANCIES TO THE NUMBERS ON THE TITLE SHEET. DAMAGE DURING THE CONSTRUCTION PROCESS, AND SHALL CLEAN UP AFTER THEMSELVES AT THE END OF EACH WORKING DAY. DISPOSED OF EACH DAY. NO RUBBISH SHALL BE LEFT IN THE PREMISES AFTER WORK RESPONSIBLE FOR REVIEWING THEIR RESPECTIVE REQUIREMENTS AND COORDINAT- ING THEIR HIDDEN OR EXPOSED WORK WITH OTHER RELATED TRADES. ASSURE EFFICIENT AND ORDERLY INSTALLATION. PROVIDE ACCOMMODATION FOR ITEMS INSTALLED AT A LATER DATE. VERIFY THAT CHARACTERISTICS OF ELEMENTS OF INTERRELATED OPERATING EQUIPMENT ARE COMPATIBLE; COORDINATE WORK OF VARIOUS SECTIONS WHICH HAVE INTERDEPENDENT RESPONSIBILITIES FOR INSTALL- ING, CONNECTING TO, AND PLACING IN SERVICE, SUCH EQUIPMENT.COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK AND FIRE SPRINKLER SYSTEM WHICH ARE INDICATED, DETAILED, OR IMPLIED EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT AND MACHINERY, AND OTHER FACILITIES AND SERVICES NECESSARY FOR PROPER EXECUTION AND COMPLETION OF WORK, INCLUDING PERMITS. UTILITIES SHALL BE PROVIDED BY OWNER. ACCORDANCE WITH THE REQUIREMENTS OF THE LANDLORD AND THE TENANT. VERIFY AND COORDINATE WITH THE TENANT FOR ANY ADDITIONAL REQUIREMENTS. IMMEDIATELY AFTER RECEIPT OF NOTICE TO PROCEED FOR USE IN CONVENIENCE OF ALL THOSE ENGAGED IN THE PROJECT WORK. SUCH AREAS CLEAN AND FREE OF CONSTRUCTION MATERIALS AND DEBRIS. FAILURE TO MAINTAIN CLEAN STOREFRONT WILL RESULT IN BUILDING MANAGEMENT HAVING SUCH MATERIALS AND DEBRIS REMOVED AND ALL CHARGES FOR MAINTENANCE WILL JOHN'S REVIEWING ALL SCHEDULED ACTIVITIES AT OUTSET OF CONSTRUCTION. THE WORK INCLUDES NEW TENANT IMPROVEMENTS IN AN EXISTING SPACE, PER 2. PRIOR TO BEGINNING THE WORK, VERIFY ALL EXISTING DIMENSIONS AND SQUARE3. CONTRACTORS SHALL TAKE CARE TO PROTECT ADJACENT AREAS FROM DUST AND ALL RUBBISH AND TRASH SHALL BE REMOVED FROM THE PREMISES AND PROPERLY 4. 5. IS COMPLETED EACH DAY. ALL DRAWINGS HEREIN CREATE AN ENTIRE PACKAGE. ALL TRADES SHALL BE6. COORDINATE ALL WORK OF THE VARIOUS TRADES AND SUBCONTRACTORS TO7. UNLESS SPECIFICALLY NOTED, PROVIDE AND PAY FOR LABOR, MATERIALS AND8. DIAGRAMMATICALLY ON DRAWINGS. GENERAL CONTRACTOR SHALL PURCHASE AND MAINTAIN INSURANCE COVERAGE IN9. FURNISH ALL REQUIRED TEMPORARY FACILITIES AND ALL TEMPORARY UTILITIES10. ALL CONTRACTORS MUST STAY BEHIND THE BARRIERS AND MAINTAIN ACCESS TO11. BE BILLED TO GENERAL CONTRACTOR. COORDINATE ALL CONSTRUCTION AND SCHEDULING WITH THE LANDLORD/JIMMY12. DIVISION 1 - GENERAL REQUIREMENTS ALL FIXTURES RECESSED IN THE CONCRETE FLOOR (I.E. GREASE TRAP, FLOOR DRAINS, FLOOR SINKS, ETC.) ARE TO HAVE THEIR FINISHED TOP LEVEL WITH THE TOP OF THE FINISHED FLOORING (I.E. TILE) AND NOT THE CONCRETE SLAB UNLESS OTHERWISE NOTED. ALL CLEANOUTS, WATER LINES, PIPES THRU WALLS, ETC. ARE TO BE A MINIMUM OF 10" TO BOTTOM AFF AND CONSISTENT THROUGHOUT ENTIRE SPACE. ALL GRILLE COLLARS SHALL BE ATTACHED TO DUCTWORK WITH POP RIVETS WITH A FINISHED THE SUPPORTS FROM THE STRUCTURE ARE TO BE A MINIMUM OF 3/8" THREADED ROD ALL THREADED ROD USED TO SUPPORT THE HOOD IS TO BE COVERED WITH PVC (SUPPLIED AND INSTALLED BY SUBCONTRACTOR) TO CREATE A WASHABLE SURFACE ALL DUCT JOINTS SHALL BE SEALED USING DUCT SEAL AS MANUFACTURED BY UNITED SHEET METAL, OR EQUAL. RED DUCT TAPE SHALL NO BE ACCEPTED. ALL EXPOSED SPIRAL DUCT SHALL BE SINGLE WALL UNINSULATED, WITH DUCT BOOTS ATTACHED COVERS ON THE THERMOSTAT ARE TO BE EQUIPPED WITH AND ABLE TO BE LOCKABLE SUBCONTRACTOR IS TO SUPPLY AND INSTALL ALL BLOCKING REQUIRED TO HANG/MOUNT LIGHTS (INCLUDING RESTROOM FIXTURES). BLOCKING IS TO BE FIRE RATED IF REQUIRED THERE WILL BE NO MC RUNNING HORIZONTALLY OVER 12" IN LENGTH IN ANY EXPOSED AREA OR AREAS VISIBLE TO THE CUSTOMER. ANY HORIZONTAL CONDUIT MUST BE LEVEL. THE OUTLET MOUNTED BELOW THE SLICER TABLE MUST BE A LEVITON MODEL BY LOCAL CODES DETAILED SPEC FOUND ON E-3 SHEET - - ELECTRIC: - FILLET OF ELASTOMER SEAL AT JUNCTION AT A 45 DEGREE ANGLE DOWNWARD OFF OF DUCT. - - - - HVAC: - - REPRESENTATIVE OF GC. - - ALL FLOOR DRAINS, FUNNEL DRAINS, CLEAN OUTS, FLOOR SINKS ETC ARE TO BE CAST IRON PROVIDE & INSTALL ALL BLOCKING REQUIRED TO MOUNT SINKS, FAUCETS, ETC. ALL BLOCKING IS TO BE FIRE RATED IF REQUIRED BY LOCAL CODES. BRASS OR PLASTIC AS SPECIFIED WITHIN THE CONTRACT DOCUMENTS. - PLUMBING: - 4. FINISH WORK SHALL BE UNIFORM, OF APPROVED COLOR, SMOOTH AND FREE FROM CLEAN. WHERE HIGH GLOSS ENAMEL IS USED, LIGHTLY SAND UNDERCOAT TO OBTAIN RUNS. MAKE ENDS OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND APPLY NO FINISH MATERIAL UNTIL THE UNSUITABLE SURFACES HAVE BEEN MADE PAINTED OR STAINED IS FOUND TO BE UNSUITABLE TO PRODUCE PROPER FINISH. 3. PAINT CONTRACTOR SHALL NOTIFY THE GENERAL CONTRACTOR IF ANY SURFACE TO BE COMMENCING THE WORK. STORE, CLEAN, AND REPLACE UPON COMPLETION. ESCUTCHEONS, REGISTERS, SURFACE HARDWARE, FITTING, AND FASTENINGS PRIOR TO ELECTRICAL OUTLET AND SWITCH PLATES, MECHANICAL DIFFUSSERS, GRILLES, WORK. REPAIR ANY DAMAGE CAUSED BY THE WORK OF THIS SECTION. REMOVE 2. PROTECT WORK OF OTHER TRADES FROM DAMAGE AND DEFACEMENT CAUSED BY THIS FINISH, NON-MECHANICAL ROOM SPACES. NO PAINTING IS REQUIRED FOR INSULATED PIPING, EXCEPT WHERE EXPOSED IN ALTERATIONS OCCUR OR WHERE SCHEDULED. PAINT GRILLES AND DIFFUSSERS. STAINLESS STEEL; INTERIOR OR EXTERIOR OF EXISTING BUILDING, EXCEPT WHERE NON-FERROUS METAL UNLESS SPECIFICALLY MENTIONED IN THE FINISH SCHEDULE; AS MAY BE SPECIFIED HEREINAFTER; PUTTY AND/OR SEALANT AT ALUMINUM WINDOWS; DRAWINGS OR AS SPECIFIED HEREINAFTER INCLUDING SEALING OF CONCRETE FLOOR 1. PROVIDE PAINT FINISHES FOR BUILDING AND OTHER SURFACES AS SCHEDULED ON PAINTING NO PAINT FINISH IS REQUIRED ON ITEMS HAVING COMPLETE FACTORY FINISH, EXCEPT A SMOOTH FINISH COAT. SATISFACTORY. MANUFACTURER'S LABEL AND SHOWING PAINT TYPE, SHEEN AND COLOR. 6. DELIVER ALL PAINT TO JOBSITE IN UNOPENED CONTAINERS BEARING THE COATS FINAL COLOR COAT TO ACHIEVE UNIFORM FINISH. 5. PROVIDE ALL NEWLY PAINTED SURFACES WITH (1) COAT TINTED PRIMER AND (2) 1. CONCRETE: - ALL CONCRETE IS TO BE CUT AND REMOVED, AS OPPOSED TO THE USE OF JACKHAMMERS. - ALL REMOVED CONCRETE IS TO HAVE A 10 MIL VAPOR BARRIER PLACED ON TOP OF BACKFILL AREAS PRIOR TO REPLACING OF THE CONCRETE. - ALL CUT AREAS OF CONCRETE ARE TO BE DRILLED AND PINNED USING ½" REBAR AND TO BE SPACED AT A MAXIMUM OF 16" APART. PINS ARE TO BE DRILLED AND EPOXY GROUTED INTO THE EXISTING CONCRETE AT LEAST 6" AND HAVE AT LEAST 6" EXPOSED. - CONCRETE IS TO BE PLACED TO ENSURE THAT A FLUSH AND SMOOTH TRANSITION EXISTS WITH THE EXISTING CONCRETE. ANY RAISED OR LOWERED AREAS WILL HAVE TO BE CORRECTED BY THE CONTRACTOR RESPONSIBLE FOR THE PLACEMENT OF THE CONCRETE. - NEW SLAB ON GRADE CONCRETE TO BE 4" CONCRETE SLAB ON GRADE WITH FIBERMESH REINF. OR 4" CONCRETE SLAB ON GRADE WITH 6x6-W1.4xW1.4 WWF ON 10 MIL VAPOR BARRIER OVER 4" DGA OR GRAVEL FILL. 2. FRAMING, DRYWALL, ACOUSTICS & FRP: - ALL OUTSIDE CORNERS ARE TO HAVE CORNER BEAD SECURELY CLENCHED ON AND TAPED -EXCEPT AT TILED AREAS. - DRYWALL TO BE SCREWED 12" OC IN THE FIELD, AND EVERY 6" ON THE EDGES OR AS REQUIRED BY CODE AND/OR RATED WALL REQUIREMENTS. - ALL DRYWALL IS TO BE FINISHED TO AT LEAST A LEVEL 4 FINISH, ENSURING THAT ALL DRYWALL IS STRAIGHT, TRUE AND BLEMISH FREE, READY TO ACCEPT FINISHES. THIS MEANS ALL DRYWALL, ALBEIT AT DECK HEIGHT OR BEHIND ANY TILE. - ACOUSTICAL CEILING IS TO HAVE HANGERS LOCATED AT 4' INTERVALS THROUGHOUT THE FIELD. ADDITIONAL HANGERS MAY BE REQUIRED TO ENSURE THAT A MAXIMUM DISTANCE OF 8" FROM THE WALL IS MAINTAINED. THIS INCLUDES ALL MAINS AND CROSS RUNNERS - ALL METAL STUDS, ANGLED SUPPORTS, ETC ARE TO BE A MINIMUM OF 20 GAUGE. IF CONSTRUCTION DOCUMENTS LIST A HEAVIER GAUGE FOR PARTICULAR FRAMING MEMBERS (I.E. PLATFORMS, ETC) THEN THE GAUGE LISTED WITHIN THE DOCUMENTS IS TO BE USED, AT A MINIMUM. - ALL WALLS ARE TO BE WIPED FREE OF ALL DUST FROM SANDING, ETC BY THE DRYWALL CONTRACTOR. - ALL UNI-STRUT, THREADED RODS, WOOD BLOCKING AND FIRE STOPPING REQUIRED TO SUPPORT OR STIFFEN ANY OF THE FRAMING IS TO BE SUPPLIED AND INSTALLED BY THE SUBCONTRACTOR - TOP OF THE SHELVING AT THE FRONT SOFFIT IS TO BE 3/4" PLYWOOD - ALL WOOD FOR BLOCKING, SUPPORTS, ETC IS TO BE FIRE RATED IF REQUIRED BY LOCAL CODES - ALL THREADED ROD LEFT EXPOSED IN THE PREP AREA IS TO BE COVERED WITH PVC (SUPPLIED AND INSTALLED BY SUBCONTRACTOR) TO CREATE A WASHABLE SURFACE - FRP IS TO BE SMOOTH FINISH, NOT PEBBLED. ALL TRIMS AND MOLDINGS ARE TO BE MITERED, FIT PROPERLY AND TIGHT AT ALL JOINTS. UNDER NO CIRCUMSTANCE IS CAULKING TO BE USED AT JOINTS OR MOLDINGS TO FILL ANY GAPS OR IMPERFECTIONS IN THE INSTALLATION. -A SHEET OF 5/8" PLYWOOD IS TO BE INSTALLED AS BLOCKING BEHIND THE DESK AREA - ALL FRAMING MUST EXTEND TO DECK(UNLESS NOTED OR APPROVED OTHERWISE). 3. TILE: - SUBCONTRACTOR IS TO SUPPLY THE LABOR REQUIRED TO RECEIVE THE MATERIALS AT THE JOB SITE. COORDINATE TIME WITH THE GENERAL CONTRACTOR - ALL GROUT IS TO BE SMOOTH AND FREE OF ALL HOLES, DIVOTS, BLEMISHES, ETC. ANY DEFECTS WILL BE REPAIRED BY THE SUBCONTRACTOR - GROUT RELEASE IS TO BE USED ON ALL AREAS CONTAINING THE QUARRY TILE - ALL TILE SURFACES ARE TO BE WIPED COMPLETELY CLEAN BY THE SUBCONTRACTOR AND LEFT FREE OF ANY HAZING, GROUT RESIDUE, FILMS, ETC. 4. PAINTING: - ALL LINES AND TRANSITIONS BETWEEN DIFFERENT COLORS ARE TO BE CRISP, STRAIGHT AND LEVEL - A TINTED GRIPPING PRIMER IS TO BE USED ON THE DOOR FRAMES - ALL SURFACES ARE TO RECEIVE (1) COAT OF PRIMER - THE TOP EDGE OF THE TILE IS TO BE CAULKED TIGHT WITH A CONTINUOUS BEAD BEFORE PAINTING - TOPS OF THE DOOR JAMBS / FRAMES MUST BE FINISHED - BOTH THE TOPS AND BOTTOMS OF THE DOORS ARE TO BE FINISHED - THE TOP SURFACE OF EVERYTHING (I.E. SHELF AT BULKHEAD) IS TO BE FINISHED. THE JIMMY JOHN'S BUILD OUT MANUAL IS TO BE USED IN CONJUNCTION WITH BLUEPRINT DRAWINGS. ANY DISCREPANCIES MUST BE BROUGHT UP TO THE JIMMY JOHNS CONSTRUCTION DEPARTMENT. JIMMY JOHN'S CORPORATE NOTES: ALL SUPPLY LINES AND DRAINS MUST BE SECURED AND FREE FROM MOVEMENT AT PENETRATIONS - 5. REVIEW ALL AREAS TO RECEIVE TILE FLOORING (PRIOR TO SUBMITTING BID) APPROXIMATELY, 1/2" ABOVE CONCRETE. IF THE FLOOR IS NOT CONCRETE, VERIFY WITH ONSITE C.COORDINATE THIS WORK WITH OTHER TRADES INVOLVED TO AVOID DELAYS AND TO INSURE A SATISFACTORY AND WATERTIGHT INSTALLATION. INSTALL ALL REQUIRED MATERIALS IN A PROPER MANNER TO INSURE AN AIRTIGHT, WATERTIGHT, AND WEATHERPROOF INSTALLATION. CONTRACTORS SHALL REVIEW PLANS FOR DISCREPANCIES AND VISIT THE PREMISES DURING THE BID PROCESS AND SHALL FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND THE REQUIREMENTS OF THE PROJECT PRIOR TO DEVELOPING THEIR BID. A SUBMISSION OF BID SHALL IMPLY THAT THE CONTRACTOR HAS ACCEPTED THE DRAWINGS, EXISTING CONDITIONS, AND REVIEWED THE PLANS FOR ANY DISCREPANCIES. MATERIAL QUANTITIES SHALL BE BASED ON ACTUAL FIELD CONDITIONS AND MEASUREMENTS. DO NOT RELY ON SCALING PLANS FOR ACCURATE DIMENSIONING. 28.THE CONTRACTOR SHALL OBTAIN ALL BUILDING PERMITS, APPROVALS, CALLS FOR INSPECTIONS, ETC. THE OWNER SHALL REIMBURSE THE CONTRACTOR FOR THE AMOUNT OF FEES PAID FOR THIS. 29.TEMPORARY SERVICES: ANY REQUIRED TEMPORARY ELECTRICAL POWER AND LIGHTING SYSTEMS SHALL BE FURNISHED, INSTALLED AND REMOVED BY THE CONTRACTOR. 30.CONTRACTOR SHALL NOT UNDER ANY CIRCUMSTANCES, ALTER THE CONSTRUCTION DOCUMENTS. IF SITE CONDITIONS REQUIRE MODIFICATIONS TO THE PLANS, ALL MODIFICATIONS SHALL BE SUBMITTED TO THE ARCHITECT AND APPROVED PRIOR TO PROCEEDING WITH THOSE MODIFICATIONS. CONTRACTOR SHALL ASSUME LIABILITY FOR ANY MODIFICATIONS TO PLANS WHICH ARE NOT APPROVED IN WRITTING BY THE ARCHITECT. CONTRACTOR SHALL REPLACE, AT HIS OWN EXPENSE, ANY ITEMS NECESSARY TO BRING THE STORE INTO COMPLICANCE WITH THE DRAWINGS. DIRECTIONS. OF PATCH. INSTALL PER MANUFACTURER'S LATEST WRITTEN AND RECOMMENDED 2. ANY HOLES GREATER THAN 1/2". AND LEVELING JOINTS AND CRACKS; AND FILLING ABANDONED ELECTRICAL BOXES AND 1. DIVISION 3 - CONCRETE REPAIR AND REPLACEMENT ENCOUNTERED; DISPOSE OF BY SAFE MEANS TO PROTECT HEALTH OF WORKERS AND 10. 9. 8. OF THE BUILDING, IN ACCORDANCE WITH GUIDELINES AND STIPULATIONS OF LOCAL PREVENT WEATHER DAMAGE OR SPREAD OF DUST, FUMES AND SMOKE TO OTHER PARTS 7. ERECT AND MAINTAIN WEATHERPROOF AND DUSTPROOF CLOSURES AND PARTITIONS TO DEMOLISHED IMMEDIATELY FROM THE SITE. STORE IN A SECURE LOCATION. REMOVE DEBRIS, REFUSE AND MATERIALS BEING 6. VALVE AND SMOKE ALARM PRIOR TO COMMENCING WORK; COORDINATE REQUIRED OF DISCONNECTED SERVICES. WHERE APPLICABLE, LOCATE SPRINKLER SHUT-OFF WITHIN AREAS AFFECTED BY DEMOLITION. PLACE MARKERS TO INDICATE LOCATION 5. SUCH MOVEMENT, SETTLEMENT DAMAGE OR INJURY. DETERMINED BY G.C. ENLISTED STRUCTURAL ENGINEER. ASSUME LIABILITY FOR AND SHORING AND BE RESPONSIBLE FOR SAFETY AND SUPPORT OF STRUCTURE, AS 4. 2. PUBLIC. JURISDICTION. 1. DIVISION 2 - DEMOLITION / BUILDING ALTERATIONS C. ALL RUNNING TRIM ONE (1) PIECE UP TO 10' - 0". MATCH GRAIN AND B. MITER CASINGS, MOLDING, BASE AND STOREFRONT LAMINATED OR PAINTED MDF PANELS. 10. 9. 8. 7. A. INSTALL ALL MATERIAL WITH TIGHT JOINTS. CONSIDERATIONS AND REQUIREMENTS: SOLVENT AND CLEANING PROCEDURES. COLOR PIECE-TO PIECE. REPLACE DAMAGED SURFACES. APPLICATION: INSTALL IN ACCORDANCE WITH MANUFACTURER'S MOST CURRENT 5. 4. 3. 2. PRINTED APPLICATION INSTRUCTIONS. 6. NOMINAL THICKNESS; EASE ALL EXTERNAL CORNERS. FOR ATTACHMENT OF WOOD TRIM TO METAL STUDS, RUNNERS OR FURRING. LOCAL CODE OR APPROVED BY ARCHITECT. CONDITI0N FOR INSTALLATION. DIVISION 6 - WOOD AND PLASTICS DIVISION 4 - UNIT MASONRY AUTHORITIES & LANDLORD. MODIFICATION WITH LANDLORD. 1. MILL NUMBER OR NAME, GRADE OR LUMBER SPECIES OR SPECIES GROUPING B. ALL LUMBER IS TO BE GRADE STAMPED AND IS TO CONTAIN GRADING AGENCY, COMBINATION DESIGNATION, RULES UNDER WHICH GRADED, WHERE APPLICABLE. WITHOUT SPLITTING WOOD, FASTEN PANEL PRODUCTS TO ALLOW FOR EXPANSION SIDE WILL BE EXPOSED TO VIEW OR RECEIVE FINISH MATERIALS. INSTALL FASTENERS USING FASTENERS OF SIZE THAT WILL NOT PENETRATE MEMBERS WHERE OPPOSITE E. SECURELY ATTACH CARPENTRY WORK TO SUBSTRATES AND SUPPORTING MEMBERS AT JOINTS UNLESS OTHERWISE INDICATED. ACCESSORIES, AND ELSEWHERE AS REQUIRED. MEMBERS. PROVIDE BLOCKING WHERE REQUIRED FOR ANCHORAGE OF CASE WORK, WOOD BLOCKING NOT LESS THAN 2" THICK, IF NOT BLOCKED BY OTHER FRAMING STRUCTURAL MEMBERS BETWEEN SUPPORTS. FIRESTOP CONCEALED SPACES WITH F. PROVIDE WOOD FRAMING MEMBERS OF SIZE AND SPACING INDICATED. DO NOT SPLICE PREVENT MOVEMENT OR SETTLEMENT OF STRUCTURE. PROVIDE AND PLACE BRACING ARRANGE AND PAY FOR DISCONNECTING, REMOVING AND CAPPING UTILITY SERVICES CAREFULLY REMOVE MATERIALS AND EQUIPMENT WHICH ARE INTENDED TO BE REUSED. PERFORM DEMOLITION IN ACCORDANCE WITH APPLICABLE AUTHORITIES HAVING REMOVE FROM SITE CONTAMINATED, VERMIN INFESTED OR DANGEROUS MATERIALS REPAIR ALL DEMOLITION IN EXCESS OF THAT REQUIRED AT NO COST TO THE OWNER. WORK INCLUDES PATCHED, DEMOLISHED SLAB AND CERAMIC TILE, IF ANY; FILLING USE SLIPRO, RAECO-LITH "R-50" OR "R-100", AS APPROPRIATE, DEPENDING ON THICKNESS ROUGH CARPENTRY USE FINISH OR CASING NAILS FOR EXPOSED WORK; USE TYPE "S" TRIM HEAD SCREWS PROVIDE ALL NECESSARY ROUGH HARDWARE IN SIZES AND QUANTITIES REQUIRED BY INSTALL LAMINATES ONLY WHEN RECEIVING SURFACES ARE IN A SATISFACTORY RELIEVE BACKS OF WOOD TRIM; KERF BACKS OF MEMBERS MORE THAN 5" WIDE AND 1" USE ADHESIVES RECOMMENDED BY THE MANUFACTURER FOR THE PARTICULAR INSTALL WOODS AND PLASTICS IN CONFORMANCE WITH DETAILS, WITH THE FOLLOWING FILL IN ALL SEAMS WITH MANUFACTURER'S APPROPRIATE COLOR SEAM COMPOUND. REMOVE EXCESS ADHESIVE AND CLEAN SURFACES USING MANUFACTURER'S RECOMMENDED PROTECT FROM DAMAGE BY OTHER TRADES WORKING ADJACENT TO THE INSTALLATION. DRAWINGS AND SPECIFICATIONS APPLY TO THIS WORK. 1. RELATED DOCUMENTS PROTECT WOOD FLOOR FROM MOISTURE. 2. JOB CONDITIONS ALL MASONRY UNITS SHALL BE REPAIRED, REPOINTED AND CLEANED BEFORE 3. REPAIR, POINTING AND CLEANING ACCEPTANCE. USE COMMERCIAL CLEANING MATERIAL PROSOCO "SURE KLEAN 600" DETERGENT GENERAL-PURPOSE CLEANER FOR BRICK, APPLY PER MANUFACTURERS PRINTED SPECIFICATIONS. DRY BRUSH AT END OF EACH DAYS WORK. EXISTING BRICK (NOT USED) FINISHES TO BE FIRE RETARDANT TREATED UNLESS NOTED OTHERWISE. L. K. I. H. F. D. BE USED FOR ALL WOOD FRAMING MEMBERS AND BLOCKING. EXPOSED WOOD FIRE PROTECTION ASSOCIATION (NFPA) RECOMMENDATIONS. J. G. SINK AND PUTTY IN FINISH WOOD SURFACES. E. WHERE SCREWS DO NOT SHOW. NON-COMB. FIRE TREATED WOOD BEARING FACTORY IMPREGNATED STAMP SHALL INSTALL FIRE RATED DOORS IN ACCORDANCE WITH REQUIREMENTS OF NATIONAL FINISH EXPOSED SURFACES SMOOTH, FREE FROM TOOL AND MACHINE MARKS. SELECT AND CUT MATERIAL TO EXCLUDE DAMAGED, MARKED, OR DEFECTIVE AREAS. USE FINISH NAILS EXCEPT WHERE SCREWS ARE SPECIFICALLY CALLED FOR OR EASE ALL EXPOSED WOOD EDGES 1/8" MINIMUM RADIUS. ALL MEMBERS AND LINES LEVEL AND PLUMB. SET FASTENERS FOR PUTTYING. WHERE SCREW ATTACHMENT REQUIRED, SPACE SCREWS AT EQUAL INTERVALS; THE WORK MAY INCLUDE DEMOLITION OF EXISTING CONSTRUCTION, REMOVAL OF VARIOUS ITEMS OF EQUIPMENT AND CONSTRUCTION, AND THE CUTTING OR ALTERATION OF EXISTING CONSTRUCTION AS SHOWN. NOTED OR IMPLIED ON THE DRAWINGS. CONTRACTOR SHALL DETERMINE AND INVENTORY ALL NECESSARY DEMOLITION AND ALTERATION OF ITEMS TO PROVIDE FOR A COMPLETE INSTALLATION OF NEW WORK. ALL COSTS OF REMOVAL REPAIR OR REPLACEMENT SHALL BE INCLUDED IN THE BID. ADDITIONAL COSTS FOR DEMOLITION OF ITEMS HIDDEN OR INACCESSIBLE DURING THE BIDDING PHASE, SHALL BE SUBMITTED FOR APPROVAL PRIOR TO BEGINNING THE WORK. AT ALTERED CONSTRUCTION REPAIR CUT EDGES, REPLACE CONSTRUCTION. AND FIT NEW TO EXISTING CONSTRUCTION TO MATCH EXISTING WORK, MAKE JOINTS OF NEW AND EXISTING PATCHES VERY SMOOTH, EVEN AND PRACTICALLY INVISIBLE. COORDINATE ALL REPLACEMENT AND REPAIR REQUIREMENTS WITH LANDLORD'S CONSTRUCTION CRITERIA AND TENANTS COORDINATOR. SAW-CUT CONCRETE ON GRADE WITH DIAMOND SAW; JACKHAMMERING WILL NOT BE PERMITTED EXCEPT WITH THE EXPRESSED WRITTEN APPROVAL OF THE LANDLORD AND JJ. CUT IN ACCURATELY LOCATED STRAIGHT LINES AND BREAK OUT SECTIONS. FLOOR 3.DOORS AND FRAMES: IF DOORS AND FRAMES ARE TO BE REUSED ON THE WORK, CAREFULLY REMOVE DOOR FROM FRAMES AND REMOVE FRAMES FROM OPENING, TAKING CARE TO AVOID DAMAGE. REMOVE HARDWARE, CLEAN REFURBISH, AND STORE FOR REINSTALLATION. D. INSTALL ROUGH CARPENTRY WORK TO COMPLY WITH APPLICABLE CODE STANDARDS UNLESS OTHERWISE INDICATED. FOR SHEATHING UNDERLAYMENT AND OTHER PRODUCTS NOT COVERED IN ABOVE STANDARDS, COMPLY WITH RECOMMENDATIONS OF MANUFACTURER OF PRODUCT INVOLVED FOR USE INTENDED. SET CARPENTRY WORK TO REQUIRED LEVELS AND LINES, WITH MEMBERS PLUMB AND TRUE AND CUT TO FIT. C. LUMBER SHALL BE PROTECTED FROM THE ELEMENTS UNTIL SUCH TIME IT IS USED IN CONSTRUCTION. A. PROVIDE ROUGH LUMBER AND PLYWOOD IN STANDARD DIMENSIONS. MOISTURE CONTENT NOT MORE THAN 19%, WITH THE INDICATION OF "S-DRY" ON THE GRADE STAMP. MAY BE CORE DRILLED WHERE APPROPRIATE FOR INSTALLATION OF PIPES AND SIMILAR ITEMS. COORDINATE ALL CORE LOCATIONS AND SLAB MODIFICATIONS WITH LANDLORD'S STRUCTURAL ENGINEER. WHERE EXISTING PIPING AND OTHER SIMILAR ITEMS ARE UNDER EXISTING SLABS, EXERCISE CARE TO PROTECT FROM DAMAGE EXERCISE CARE WHEN CUTTING ADJACENT TO EXISTING WALLS TO AVOID DAMAGE TO WALLS IF DAMAGED, REPAIR AS REQUIRED TO ORIGINAL CONDITION. DO NOT CUT SUSPENDED SLAB EXCEPT AS NOTED ON DRAWINGS. CEILING PANELS - 2' x 2' USG ASTRO CLIMA PLUS #8221 CEILING TILE(DINING) E. MINIMUM 14. GA. FOR WATER HEATER PLATFORM FRAMING. C. ONE BOX OF EACH CEILING TILE FREE OF DAMAGE. B.ALL MATERIALS INCLUDING FELTS, COMPOSITION FLASHING, BITUMEN, ROOF INSULATION, VAPOR RETARDER, (IF ANY), AGGREGATE SURFACING OR OTHER COATING, ETC. IS TO BE COMPATIBLE W/EXIST. ROOFING SYSTEM TO COMPLETE THE PATCHING OF THE EXIST. ROOF A.FURNISH ALL LABOR, MATERIALS, TOOLS, EQUIPMENT AND SCAFFOLDING REQUIRED FOR COMPLETING ROOFING WORK, FLASHING AND ASSOCIATED SHEET METAL WORK AND RELATED ITEMS INDICATED ON THE DRAWINGS AND SPECIFIED HEREIN. (NOTE: REFER TO DRAWINGS FOR ITEMS APPLICABLE TO THE PROJECT) ROOF PATCHING: FE FE FE A A-5 103 UNISEX 10 TYP. 3 33 3 3 33 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 1 1 22 2 2 2 2 2 2 2 2 2 2 2 2 2 1 2 3 TYP. 10 100 DINING TYP. 10 101 PREP 102 BACKROOM 10 TYP. 4 14 14 14 6 6 2 9 5 7 8 B A-10 C A-10 A A-10 22 22 22 22 22 22 22 2222 21 13 12 20 5 A-1 1 A-1 SIM D A-10 5 A-1 72" POLISHED S.S. CORNER GUARD FROM TOP OF BASE TO 78" A.F.F. - APPLY CONT. BEAD OF SILICONE - INSTALL AFTER FINAL WALL FINISH SUBWAY TILE ON GYP. BOARD OVER METAL STUDS - SEE ELEVATIONS FOR FINISHES FRONT PREP BACK-OF-HOUSE FRP 1-1/2" x 1-1/2" NON INTEGRATED OUTSIDE CORNERS DOOR NUMBER HDWR GROUPJAMB DETAILS HEAD SILL REMARKS FINISHFINISHMATERIAL DOOR MATERIALTYPEDOOR SIZE FRAME TYPE 1 D O O R S C H E D U L E D O O R H A R D W A R ED O O R N O T E S FACTORY ALUM./GLASS1 01 DOOR TYPES NOTE: PRIVACY LOCK (US26D) (1 1/2) PAIR HAGER HINGES BB1279, 4 1/2 x 4 1/2 (US26D FIN.) (1) LCN SUPER SMOOTHEE DOOR CLOSER SERIES #4041 (HINGE SIDE MOUNT) (US26D FIN.) (1) LOCKSET- SINGLE CYCLINDER DEAD BOLT SECURITY LOCK BY U-CHANGE INDUSTRIES DOOR (1) CLOSER- AUTOMATIC CORBIN-RUSSWIN DC2200 SERIES (US26D) HINGES- TOP, BOTTOM & STANDARD INTERMEDIATE OFFSET PIVOTS (EXISTING) (1) PULL- STYLE G2 BLACK FOR KAWNEER DOORS OR SIMILAR (DOOR 1) ALL DOOR HARDWARE FINISH TO BE US26D (TYP.). ALL DOOR HARDWARE FINISH TO BE US26D (TYP.). (2) 6"x34"- BALDWIN BRUSHED S/S KICKPLATES (BOTH SIDES) HARDWARE SET NO. 1: (CONTRACTOR TO V.I.F.) HARDWARE SET NO. 2: (1) AUGUSTA LEVER HANDLE HARDWARE SET NO. 3: HARDWARE SET NO. 2: EGRESS DOORS SHALL BE READILY OPENABLE FROM THE EGRESS SIDE W/O THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT. (1 1/2) PAIR HAGER HINGES BB1279, 4 1/2 x 4 1/2 (US26D FIN.) (1) LCN SUPER SMOOTHEE DOOR CLOSER SERIES #4041 (US26D FIN.) (1) DELTANA DEL-WBC250US26 2 1/2" WALL BUMPER ALL DOOR HARDWARE FINISH TO BE US26D (TYP.). (1) AUGUSTA LEVER HANDLE (1) 6"x34"- BALDWIN BRUSHED S/S KICKPLATES INTERIOR SIDE ONLY) 1.EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. EXCEPTIONS : 1. IN GROUP M OCCUPANCIES, KEY-LOCKING HARDWARE MAY BE USED ON THE MAIN EXIT WHEN THE MAIN EXIT CONSISTS OF A SINGLE DOOR OR PAIR OF DOORS IF THERE IS A READILY VISIBLE, DURABLE SIGN ON OR ADJACENT TO THE DOOR STATING "THIS DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED". THE SIGN SHALL BE IN LETTERS NOT LESS THAN 1 INCH HIGH ON A CONTRASTING BACKGROUND. WHEN UNLOCKED, THE SINGLE DOOR OR BOTH LEAVES OF A PAIR OF DOORS MUST BE FREE TO SWING WITHOUT OPERATION OF ANY LATCHING DEVICE. 2.ALL FIRE RATED DOORS AND ALL EXTERIOR SWINGING DOORS SHALL HAVE CLOSURES. 3.ALL INTERIOR DOORS TO BE SOLID WOOD CORE, WITH BIRCH VENEER - PAINTED. 4.ALL NEW/REPLACED DOOR HARDWARE SHALL BE BRUSHED ALUMINUM/SATIN CHROME (US 26D FINISH). 5. ENTRY/EXIT DOORS TO HAVE SIGN - " THIS DOOR TO REMAIN UNLOCKED WHILE BUILDING IS OCCUPIED" POSTED. 6.DOOR OPENING FORCE SHALL NOT EXCEED 5 LBS. 7.ALL DOOR OPERATING HARDWARE SHALL BE MOUNTED AT 38" A.F.F. 8. DOOR HARDWARE MUST BE OPERABLE BY A SINGLE HAND WITHOUT TIGHT GRASPING, TIGHT PINCHING OR TWISTING. 9. "T" INDICATES TEMPERED GLASS. 10. HOLLOW METAL FRAMES MUST BE 2" WELDED FRAMES. 11. ALL INTERIOR DOOR CLOSURES MUST NOT BE SEEN FROM DINING SIDE 12. SILENCERS REQUIRED FOR ALL DOORS (1) DELTANA DEL-WBC250US26 2 1/2" WALL BUMPER (1) YALE AU4602LN 626 AUGUSTA LEVER HANDLED REMARKS 1. PROVIDE WOOD BLOCKING FOR DOOR STOPS. 2. CLOSER TO BE MOUNTED ON DOOR, NOT FRAME. CLOSER TYPE TO BE 90° OPENING. 3. PAINT DOORS AND FRAMES BOTH SIDES PT-6. 4. CONTRACTOR TO CONFIRM EXISTING DOOR AND DOOR FRAME ARE IN GREAT CONDITION. REPLACE TO MATCH JIMMY JOHN'S SPECIFICATIONS IF NOT. 5. EXTERIOR SIDE OF DOOR TO BE PAINTED TO MATCH EXISTING ADJACENT SURFACE. 6. PAINT DOOR AND FRAME PT-3 (ALABASTER) WHEN IN BACK OF HOUSE. 7. PROVIDE H.C. ACCESSIBLE MEN'S/WOMEN'S SIGNAGE AT WALL OUTSIDE OF DOOR AS REQUIRED BY GOVERNING AUTHORITIES. 8. RE-KEY EXISTING DOOR PER OWNER'S REQUIREMENTS. 9. REFURBISH WEATHERSTRIPPING, DOOR BOTTOM, ETC. TO LIKE NEW CONDITION 10. PROVIDE PANIC HARDWARE. EX3'-0" x 7'-0" (V.I.F.) FACTORY FINISH FINISHALUMINUM 2,4,8,9,10EXIST. 2 --- FRAME TYPES A SEE SCHEDULE SE E S C H E D U L E 2"2" PANIC HARDWARE ON INSIDE BY T.I. CONTRACTOR 5' - 0 " ST E N C I L SEE SCHEDULE SE E S C H E D U L E 1 SEE SCHEDULE 2 SE E S C H E D U L E 3 HANDICAP TOILET RM SIGNAGE SEE DETAIL N/A5 FOR SIGNAGE NOTES 3 HOLLOW METAL 1,2,3,7 HOLLOW MTL 02A2EX3'-0" x 7'-0"3/A-1 4/A-1 -PT-6PAINT PT-6 SEE SCHEDULE SE E S C H E D U L E 3 PANIC HARDWARE ON INSIDE BY T.I. CONTRACTOR PT-3 PAINT 2,4,5,6,8,9,10HOLLOW MTL EXPT-3 HOLLOW METAL -EX 3'-0" x 7'-0" (V.I.F.) EXIST.-- 2" MTL STUD BOXED HEADER, (2) METAL STUDS, W/ (2) RUNNERS (COORD W/ PARTITION TYPE) 1/2" COORD W/ JAMB SEE PARTITION TYPE FOR GYP BD THK, LAYERS & MTL STUD SIZE EXISTING WALL TO REMAIN. PATCH AND REPAIR AS REQ'D. GWB TO EXTEND TO UNDERSIDE OF DECK AT DINING ROOM. MAINTAIN EXISTING RATING. INFILL OPENING. DOOR TO BE FIXED IN CLOSED POSITION AND EDGES SEALED AGAINST AIR INFILTRATION. CONTRACTOR TO INSTALL MTL STUDS AND BATT INSULATION (R-19) AS NEEDED TO ENSURE FLUSH INTERIIOR FINISH. WALL 6" 20 ga. METAL STUDS AT 16"o.c.w/ 5/8" GWB ON EXPOSED SIDE(S). SOFFIT ABOVE COUNTER UNLESS OTHERWISE NOTED. WALL 35 8" 20 ga. METAL STUD AT 16"o.c w/ 5 8 " GWB ON EXPOSED SIDE(S). USE W.R. DRYWALL IN WET AREAS. FURRING WALL, 3 5/8" METAL STUDS ON EDGE AT 16"o.c. w/ 5 8" GWB ON EXPOSED SIDE(S). 42" HALF WALL, 35 8" 20 ga. METAL STUD AT 24"o.c. w/ 5 8" GWB ON BOTH SIDES TOPPED w/ 7" COUNTER TOP. 35 8" 20 ga. METAL STUD AT 16" o.c. w/ 5 8" GWB ON EACH SIDE. REF TO DETAIL 5/A-1.1. SEE INTERIOR ELEVATIONS FOR HEIGHT. FINISH EDGE OF WALL W A L L L E G E N D GENERAL WALL NOTES: 1.MIN 20 ga. METAL STUDS REQUIRED (MUST PROVIDE DIAGONAL CROSS BRACING FOR WALLS OVER 16'-0" @ 4'-0" O.C. SECURED TO STRUCTURE ABOVE ON DROP CEILING SIDE) 2.ALL FRAMING TO CONTINUE TO BOTTOM OF ROOF/DECK. MUST BE BRACED TO THE STRUCTURE ABOVE AS REQUIRED BY CODE. 3.USE MOLD RESISTANT GYP. BOARD FOR ALL RESTROOM, KITCHEN/BOH, & MOP SINK WALLS. 4.REFER TO SHEET A-3 FOR SCHEDULED FINISHES: 3 16" SUBWAY TILE AND 1 2" COVE BASE. 5.ALL FRAMING AND GYP. BOARD MUST EXTEND TO ROOF/DECK ON EXTERIOR & DEMISING WALLS. OPENING INFILL. WALL MATERIALS TO MATCH ADJACENT WALLS. CONTRACTOR TO INSTALL MTL. STUDS AND BATT. INSULATION AS NEEDED TO ENSURE FLUSH INTERIOR FINISH. EXISTING SEPARATION WALL. G.C. TO CONFIRM CONSTRUCTION AND MAINTAIN ANY EXISTING FIRE SEPARATION. #4 X 24" AT 16" O.C. DOWELS (TYP.) LINE OF NEW CONC SLAB TO EXISTING CONC SLAB NEW CONCRETE SLAB TO MATCH EXISTING FILL JOINT WITH EXPANSIVE MATERIAL EXISTING CONCRETE SLAB THK + 1" PARTITION 1/2" 2" SEE PARTITION TYPE FOR GYP BD THK, LAYERS & MTL STUD SIZE DOUBLE MTL STUDS HM DOOR FRAME w/ 3 JAMB ANCHORS PER SIDE 1 15/16" DOOR SIDE 19 SEE SHEET A-11 AND A-12 FOR ACTUAL LOCATION OF DRIVE THRU MENU/ ORDER BOX 18 15 17 17 17 17 19 3 5 8" MTL. STUDS @ 16" O.C. w/ 5 8" GWB ON ONE SIDE -REFER TO WALL LEGEND 6" EXISTING EXTERIOR WALL CONSTRUCTION -TO REMAIN NEW BLACK SPANDREL GLASS IN EXISTING STOREFRONT SYSTEM. COORDINATE w/ LANDLORD, OWNER, AND FRANCHISEE PRIOR TO DEMO, ORDERING AND INSTALLATION VENTILATION T/O EXIST. WINDOW NOTE: VERIFY CONDITIONS IN FIELD FOR PROPER INSTALLATION. SUSPENDED ACT CEILING JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON A-1 FLOOR PLAN AND DETAILS F L O O R P L A N K E Y E D N O T E S 1 2 3 4 5 6 7 8 9 10 12 13 EXISTING SHELL BUILDING. EXISTING WINDOWS & DOORS. EXISTING 5 8 GYP . BD. ON WALL - CONTRACTOR TO PATCH/REPAIR/EXTEND TO DECK.TAPED AND SAND SMOOTH READY FOR FINISH. SKIM COAT AS NEEDED TO RECEIVE NEW FINISH. APPLY NEW 5 8" GYP. BD. ON STUDS IF NOT EXISTING. LINE OF SOFFIT ABOVE. ELECTRICAL PANEL(S) WALK-IN COOLER/FREEZER. MOP SINK - SEE 5/A-1.1 AND PLUMBING. WATER HEATER. MANAGER DESK - SEE 4/A-1.1. CLEAN/SCRAPE/INFILL EXISTING FLOOR AND PREP AS REQUIRED FOR NEW FINISHES. FAUX COLUMN ALIGN FRAMING OF SOFFIT AND FRAMING OF FULL HEIGHT PARTITION. FRAMING OF SOFFIT WALL MUST ALIGN VERTICALLY WITH CASH COUNTER AND KNEEWALL BELOW SEE A-1.1 FINISH THIS SIDE BY OTHERS CONTRACTOR TO COORDINATE ALL REMOVAL AND PATCH BACK OF ASPHALT AND CONCRETE AS REQUIRED FOR INSTALLATION OF DRIVE THRU ORDER BOX/MENU BOARD/MAGNETIC LOOP - COORDINATE WITH EXISTING FIELD CONDITIONS. DRIVE THRU WINDOW READY ACCESS 131, SEE SHEET A-11. PATCH/PAINT WALL AS REQUIRED TO MATCH ADJACENT SURFACES. TAPED AND SAND SMOOTH READY INTERIOR FOR FINISH. SKIM COAT AS NEEDED TO RECEIVE NEW FINISH. NEW PIPE BOLLARD - SEE F/A-11. MAGNETIC LOOP FOR DRIVE THRU COMMUNICATION PANEL - SEE A-11. DRIVE THRU MENU BOARD/ORDER BOX - SEE SHEET A-11 LOCATION OF BROOM ORGANIZER AND MOP HOLDER. LOCATION OF COAT HOOKS. INSTALL BLACK SPANDREL GLASS ON EXISITING WINDOWS AND DOORS. SEE DETAIL 5/A-1. DIMENSION OF SLAB LEAVE OUT V.I.F. LINE OF STRUCTURE ABOVE. WRAP IN 5/8" GWB. AND PAINT PT-2 IF EXPOSED. G E N E R A L N O T E S 1.CONTRACTOR TO PROVIDE CIRCUITS FOR STOREFRONT SIGNS - COORDINATE WITH SIGNAGE SHOP DRAWINGS. 2.ALL MODULAR MILLWORK COMPONENTS ARE CONSTRUCTED OFF SITE BY AN APPROVED VENDOR AND ARE INSTALLED BY G.C. SEE MILLWORK SHEETS A-9 & A-10 FOR DETAILS - LOCATE AS INDICATED. 3.SEE SHEET A-1 FOR WALL LEGEND AND INFORMATION. 4. SPRINKLER DESIGN / F.A. DESIGN SHALL BE REVIEWED AND APPROVED UNDER SEPARATE PERMIT. 5. ALL SIGNAGE SHALL BE REVIEWED AND APPROVED UNDER SEPARATE PERMIT. S Y M B O L S L E G E N D X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X X DOORS X CEILING FINISHES SEE SHEET A-6 THRU A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X ARCHITECTURAL FLOOR PLAN 1/4" = 1'-0"A NORTH S.S. CORNER GUARD 3" = 1'-0"1 NOT USED11 JOINT DETAIL 1" = 1'-0"2 14 15 16 17 18 19 HEAD DETAIL 3" = 1'-0"3 JAMB DETAIL 3" = 1'-0"4 20 21 NOT USED NOT USED NOT USED 22 BLACK SPANDREL GLASS DETAIL 1" = 1'-0"5 NOT USED 101 PREP 100 DINING 103 UNISEX 102 BACKROOM 6" 4' - 1 1 / 4 " 3 5 / 8 " 2' - 5 " 3 5/8"4 1/2" 3 5 / 8 " 2' - 5 " 3 5/8"4 1/2" 3'-7 1/8" 3 5/8" 6'-7 1/4" 3 5/8" 7'-5 3/8" 22 ' - 2 3 / 8 " 17 ' - 0 3 / 4 " 30 ' - 3 1 / 2 " 3 5 / 8 " 7'-11 5/8"3 5/8"11 3/8"3 5/8" 4'-11 7/8" 10 7/8" 3' - 4 " 2' - 4 1 / 2 " 3 5 / 8 " 5' - 9 7 / 8 " 3 5 / 8 " 2 7 ' - 2 1 / 4 " 10'-0"VIF V I F 2' - 7 " 1A A-1.1 SIM. 14 ' - 1 5 / 8 " 10'-10 1/4"2'-8 5/8"10'-2 7/8" 9'-7 3/4" KNEEWALL FRAMING 8'-3 1/4" 1' - 2 1 / 2 " 5' - 4 1 / 2 " 1' - 8 " 2' - 6 " PROVIDE 5/8" PLYWOOD OVER STUDS FOR POS BRACKET 1 1 4" 1/2" = 1'-0"2 2'-6" PROVIDE SOLID 2X FIRE-RATED WOOD BLOCKING AT SHELVES IN STUD CAVITY - SEE SHEET A4 FOR LOCATIONS 2' - 1 1 " PROVIDE 5 8" FRT PLYWOOD BLOCKING BEHIND MANAGER'S DESK 3/4" = 1'-0"4 B.O. CEILING EXISTING SEPARATION WALL. G.C. TO CONFIRM CONSTRUCTION AND MAINTAIN ANY EXISTING FIRE SEPARATION. WALL 6" 20 ga. METAL STUDS AT 16"o.c.w/ 5/8" GWB ON EXPOSED SIDE(S). SOFFIT ABOVE COUNTER UNLESS OTHERWISE NOTED. WALL 35 8" 20 ga. METAL STUD AT 16"o.c w/ 5 8 " GWB ON EXPOSED SIDE(S). USE W.R. DRYWALL IN WET AREAS. FURRING WALL, 3 5/8" METAL STUDS ON EDGE AT 16"o.c. w/ 5 8" GWB ON EXPOSED SIDE(S). 42" HALF WALL, 35 8" 20 ga. METAL STUD AT 24"o.c. w/ 5 8" GWB ON BOTH SIDES TOPPED w/ 7" COUNTER TOP. 35 8" 20 ga. METAL STUD AT 16" o.c. w/ 5 8" GWB ON EACH SIDE. REF TO DETAIL 5/A-1.1. SEE INTERIOR ELEVATIONS FOR HEIGHT. FINISH EDGE OF WALL W A L L L E G E N D GENERAL WALL NOTES: 1.MIN 20 ga. METAL STUDS REQUIRED (MUST PROVIDE DIAGONAL CROSS BRACING FOR WALLS OVER 16'-0" @ 4'-0" O.C. SECURED TO STRUCTURE ABOVE ON DROP CEILING SIDE) 2.ALL FRAMING TO CONTINUE TO BOTTOM OF ROOF/DECK. MUST BE BRACED TO THE STRUCTURE ABOVE AS REQUIRED BY CODE. 3.USE MOLD RESISTANT GYP. BOARD FOR ALL RESTROOM, KITCHEN/BOH, & MOP SINK WALLS. 4.REFER TO SHEET A-3 FOR SCHEDULED FINISHES: 3 16" SUBWAY TILE AND 1 2" COVE BASE. 5.ALL FRAMING AND GYP. BOARD MUST EXTEND TO ROOF/DECK ON EXTERIOR & DEMISING WALLS. EXISTING WALL TO REMAIN. PATCH AND REPAIR AS REQ'D. GWB TO EXTEND TO UNDERSIDE OF DECK AT DINING ROOM. MAINTAIN ANY EXISTING RATINGS. OPENING INFILL. WALL MATERIALS TO MATCH ADJACENT WALLS. CONTRACTOR TO INSTALL MTL. STUDS AND BATT. INSULATION AS NEEDED TO ENSURE FLUSH INTERIOR FINISH. 12'-5" 3 4" FRT PLYWOOD BLOCKING (CONT. WITHIN STUDS) B.O. SOFFIT 3' - 0 " B.O. CEILING PROVIDE 5/8" PLYWOOD BLOCKING OVER STUDS 7' - 2 " 6' - 9 " 10 1 / 2 " 5' - 0 " SE E A - 2 6" SE E A - 2 4'-0" SHELVES PROVIDED BY BEVERAGE COMPANY WATER LINE - SEE P-1 DUPLEX OUTLET SEE E-1 1/2" = 1'-0"68 3' - 7 " 2' - 0 " 9" 4'-0" 7' - 1 0 " 9" 9" 1/2" = 1'-0"5 B.O. CEILING PROVIDE SOLID 2X WOOD BLOCKING @ 9" O.C. FOR WIRE GRIDS PROVIDE SOLID 2X WOOD BLOCKING IN STUD CAVITY FOR ALL WALL MOUNTED SHELVING (2) #12 TEK SCREWS @ EA. STUD 35 8" 20 GA. MTL STUD DIAG. BRACING @ 48" o.c. SECURED TO STRUCTURE ABOVE EXISTING ROOF SYSTEM TO REMAIN NOTE TO CONTRACTOR: VERIFY CONSTRUCTION TYPE PRIOR TO START OF NEW WORK. CONTACT ARCHITECT/ENGINEER FOR APPROPRIATE CONSTRUCTION IF EXISTING STRUCTURE DIFFERS FROM THAT SHOWN. 3/4" = 1'-0"1A 6" 2'-7" 5" 1'-3 1/2" DINING PREP 5/8" GYP. BD. (JOINTS ORIENTED VERTICALLY AND STAGGERED FROM OPPOSITE FACE) (1) 1/2" FLAT WASHERS AND (2) 1/2" NUTS. 4x4 WOOD FRAMING AT SOFFIT DOWNRODS AT 48" O.C. 35 8" 20 GA. METAL STUDS AT 16" O.C. - BETWEEN DOWNROD FRAMING 3/4" PLYWOOD - TOP OF SHELF 5/8" GYP. BD. (JOINTS ORIENTED VERTICALLY AND STAGGERED FROM OPPOSITE FACE). A.C.T. CEILING PROVIDE 12" I.D. PVC PIPE (WHITE) AT THREADED ROD (TYP.) 3 5/8" METAL STUDS AT 16" O.C. 1-1/2" x 2" CONT. STAINLESS STEEL ANGLE CORNER GUARD BY K.E.C. ELEV. 7'-6" RODS MUST NOT BE PAINTED AND STRIPPED OF PVC LETTERING AND CAULKED. METAL STUD TRACKS 5 8" GYP. BD. PAINTED PT-3 3x3x 14" STEEL ANGLE CONT. BETWEEN JOISTS RUNNER TRACK TO BE SECURED WITH TYPE S SELF TAPPING STEEL SCREWS @ 8" O.C. EDGES TAPE AND COMPOUND OVER JOINTS AND SCREW HEADS FINISH AS SCHEDULED DOWNLIGHTING ELEV. 10'-4" ELEV. 10'-6"6" MENU BOARD - G.C. TO INSTALL 3 4" PLYWOOD BLOCKING WITHIN STUDS ACROSS ENTIRE ANGLED MENU SECTION - SEE DETAIL 3/A-1.1 3" (2) 12" FLAT WASHERS (2) 12" NUTS P3008 CHANNEL NUT P1000 UNISTRUT CONT. BETWEEN JOIST AS REQ'D A-1.1 FRAMING PLAN AND DETAILS FRAMING PLAN 1/4" = 1'-0"A 1.CONTRACTOR TO SITE VERIFY ALL EXISTING CONDITIONS, CLEAR HEIGHTS, REQUIRED DEMOLITION, AND CONCRETE SLAB PRIOR TO BID. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR FAILURE TO PROPERLY INCLUDE ALL COSTS / PRICING FOR T.I. SCOPE OF WORK. 2.VERIFY LAYOUT OF ALL INTERIOR PARTITIONS PRIOR TO FRAMING. NOTIFY ARCHITECT IMMEDIATELY FOR ALL DISCREPANCIES. 3.SEE DETAIL 5/A-2 FOR CEILING BRACING AT ALL WALL TYPES. 4.SEE SHEET A-1 FOR WALL LEGEND AND INFORMATION. 5.CONTRACTOR TO SITE VERIFY EXACT FIELD CONDITIONS. PROVIDE DEMISING WALL/FULL HEIGHT GYP. BD. AS REQUIRED TO COMPLETE TENANT IMPROVEMENT SCOPE OF WORK. 6.CONTRACTOR TO INCLUDE/COORDINATE ALL REQUIRED CONCRETE FLOOR CORING IF REQUIRED FOR NEW EQUIPMENT/PLUMBING INSTALLATIONS - ALL NEW CONCRETE SHALL MATCH EXISTING SLAB/FRAMING, SEE 4/A1. 7.DIMENSIONS TO FRAMING. FRAMING PLAN ONLY. 8.REFER TO JJ's BLOCKING CHECKLIST IN BUILD-OUT MANUAL FOR ADDITIONAL MEASUREMENTS AND DETAILS. G E N E R A L N O T E S SOFFIT MENU ELEVATION NTS3 JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON NORTH NOT USED NOT USED NOT USED NOTE: ALL MEASUREMENT ARE TAKEN FROM CENTERS OF LIGHT FIXTURES. 6 8'-0" A.F.F. C-1 103 UNISEX 102 BACKROOM C-1 101 PREP 100 DINING TYP. 1 4'-0" 8' - 0 " 4' - 0 " 8'-0"3'-0"8'-0" 1' - 0 1 / 4 " 2' - 9 3 / 4 " 4'-9" 4'-7 3/8" 3' - 8 3 / 8 " 3' - 5 3 / 8 " 9'-10 1/4" 3'-0 1/8"3'-0 1/8"3'-0 1/8"1'-3 3/8" 2 2 3 A-2 10'-4" A.F.F. C-1 1 TYP. 10'-4" A.F.F. C-1 1 TYP. 6 6 3 5 4 4'-1 3/8" 10'-6" A.F.F. C-3 6 A-2 EQ . EQ . 6 2'-0" 4'-0 " 1. METAL SUSPENSION SYSTEM FOR ACOUSTICAL TILE AND LAY-IN PANEL CEILINGS SHALL CONFORM TO THE REQUIREMENTS OF ASTM C635-00 FOR HEAVY DUTY SYSTEMS. 2. INSTALLATION OF METAL CEILING SUSPENSION SYSTEM FOR ACOUSTICAL TILE AND LAY-IN PANELS SHALL CONFORM TO THE REQUIREMENT OF ASTM C636-00. 3. MAIN RUNNERS AT 4'-0" O.C. CROSS RUNNERS AT 2'-0" O.C. 4. VERTICAL HANGERS TO BE MAX. 8" FROM WALLS. NO. 12 ga VERTICAL HANGERS MAIN RUNNER MIN. OF THREE TURNS CROSS RUNNERS 1 1 CONT. 362S162-33 SECURED WITH (2) #10 TEK SCREWS AT EACH STUD MA X . S T U D C L E A R H E I G H T .4 ' - 0 " M A X CONT. 20GA. STUD BRACE AT WALL AND AT 4'-0" O.C. WITH (2) SCREWS EACH CROSSING 362S162-33 MTL. STUD BRACE AT 48" O.C. WITH (2) #10 SCREWS EACH END A-2 5 ONLY APPROVED ABOVE DROP CEILINGS EXISTING ROOF SYSTEM TO REMAIN SEE 1-1A/A-1.1 FOR CONNECTION DEFLECTION GAP #8 WAFERHEAD FRAMING SCREWS (TYP.) SLIPTRACK SYSTEMS 5 8" GWB OVER METAL STUDS, REF. TO WALL LEGEND ON FLOOR PLAN NOTE: 1. REF. TO ELEVATIONS FOR WALL FINISHES 2. G.C. TO VERIFY CONSTRUCTION TYPE PRIOR TO START OF NEW WORK. CONTACT ARCHITECT/ENGINEER FOR APPROPRIATE CONSTRUCTION IF EXISTING STRUCTURE DIFFERS FROM THAT SHOWN. 3. REFER TO WALL LEGEND ON FLOOR PLANS FOR INFORMATION ON STUDS AND DRYWALL CONDITIONS. WALL PARALLEL TO DECKWALL PERPENDICULAR / DIAGONAL TO DECK SLIPTRACK SYSTEMSLONG LEG RUNNER 5 8" GWB OVER METAL STUDS, REF. TO WALL LEGEND ON FLOOR PLAN METHOD B.O. OF CEILING EL: AS SCHEDULED COOLER AND FREEZER NOTES: NO CEILING TILE ABOVE WALK-IN FREEZER AND COOLER CONFIRM CEILING HEIGHT FOR DIRECT MOUNTED COMPRESSORS TO BE A MINIMUM OF 3'-0" ABOVE WALKINS. (CLEAR SPACE) . CONFIRM CEILING HEIGHT FOR REMOTE MOUNTED COMPRESSORS TO BE A MINIMUM OF 6" ABOVE WALKINS. (CLEAR SPACE). RETURN GRID TO TOP OF BOXES & INSTALL GRID WITH TILES FOR ENCLOSURE PANELS, PROVIDE CLIPS TO HOLD IN PLACE. CAULK BOTTOM EDGE TO FREEZER AT COOLER. INSTALL SUGGESTED MANUFACTURER CLIPS. PROVIDE EGG-CRATE GRILLS OR EQUAL FOR ADEQUATE VENTILATION PER MANUFACTURER SUGGESTED SPECIFICATION. CEILING AS SCHEDULED VERTICAL ATC, PROVIDE HOLD DOWN CLIPS AS REQUIRED COOLER/FREEZER THREADED ROD LATERAL BRACES AS NEEDED TIE CONDUIT TO THREADED ROD SET HEIGHT AT PAINT LINE SEE INTERIOR ELEVATIONS UNISTRUT, SIZE AS NEEDED FOR SPAN- CONNECT TO BAR JOISTS TRACK LIGHTS SECURED TO UNISTRUTS 5/8" GYP. BD. FINISHED W/ WT-1 TILES 3 5/8" METAL STUD FRAMING AT 16" O.C. FASTENED TO EXISTING STRUCTURE ABOVE 6" 6" ELE SEE RCP SEE RCP B.O. BULKHEAD ELE SEE RCP A-2 REFLECTED CEILING PLAN AND DETAILSREFLECTED CEILING PLAN 1/4" = 1'-0"A SUSPENDED CEILING N.T.S.1 STUD WALL BRACING 1" = 1'-0"2 SLIP TRACK AT DECK 1" = 1'-0"4 C E I L I N G P L A N K E Y E D N O T E S G E N E R A L N O T E S 1.CONTRACTOR TO PROVIDE CIRCUITS FOR STOREFRONT SIGNS - COORDINATE WITH SIGNAGE SHOP DRAWINGS. 2.ALL LIGHTS IN FOOD PREPARATION AREAS, COOLERS, FREEZERS, STORAGE AND BACK ROOMS ARE TO BE SHIELDED. 3.RETURN GRID TO TOP OF BOXES & INSTALL GRID WITH TILES FOR ENCLOSURE PANELS, PROVIDE CLIPS TO HOLD IN PLACE. CAULK BOTTOM EDGE TO FREEZER AND COOLER. INSTALL SUGGESTED MANUFACTURER CLIPS. PROVIDE EGG-CRATE GRILLS OR EQUAL FOR ADEQUATE VENTILATION PER MANUFACTURER SUGGESTED SPECIFICATION. 4.SEE SHEET A-1 FOR WALL LEGEND AND INFORMATION. 5. DIMENSIONS ARE FROM INTERIOR FACE OF EXISTING FINISHES AT EXISTING WALLS AND FACE OF FINISH MATERIAL AT NEW STUD WALLS. 6. REFERENCE SHEET E-2 FOR REQUIRED LIGHTING FIXTURE SPECS & HEIGHTS. 7. CEILING GRID MUST ATTACH TO WALL TILE AT SPECIFIED HEIGHT PER A-2. 8. SCRIM CEILING (SWA)/EXPOSED INSULATION IS NOT APPROVED ACT CEILING - COORDINATE WITH LIGHTING AND MECHANICAL ITEMS. ANY EXPOSED STRUCTURE AND OVERHEAD ITEMS NOT PAINTED. NO CEILING / TILE ABOVE COOLER / FREEZER- OPEN TO DECK. SUSPENDED CEILING GRID ABOVE SOFFIT - SEE 2/A-2. ALIGN FACE OF SOFFIT AND FACE OF FULL HEIGHT PARTITION. SOFFIT WALL FRAMING MUST ALIGN VERTICALLY WITH THE FRAMING OF CASH COUNTER AND KNEEWALL BELOW. ADD HEADER FROM ABOVE STOREFRONT WINDOW IF BOXES AND CONDUITS CAN'T BE RECESSED IN THE EXISTING WALL. ALL JUNCTION BOXES AND CONDUITS MUST BE WITHIN WALL SO A FLUSH AND SMOOTH DRYWALL FINISH CAN BE ACHIEVED. IF HEADER IS REQUIRED THEN FURR WALL ABOVE EVERY STOREFRONT WINDOW WITH 5/8" GYP. BD. ON 3 5/8" METAL STUDS. BULKHEAD STARTS AT TOP OF WINDOW OPENING. CONTRACTOR TO ADJUST CEILING HEIGHT ABOVE W/H IN ORDER TO PROPERLY COORDINATE REQUIRED PIPING CONNECTIONS - SEE 4/A-2. ACT CEILING TO BE HELD AS TIGHT TO BOTTOM OF RAFTERS AS POSSIBLE. COORDINATE WITH LIGHTING AND MECHANICAL ITEMS. ALL EXPOSED STRUCTURE AND OVERHEAD ITEMS TO BE PAINT PT-2. HVAC UNIT PLATFORM ABOVE- SEE 6/A-1 AND ELEC. DRAWINGS. 1 2 3 4 5 6 S Y M B O L S L E G E N D X X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X X DOORS X CEILING FINISHES SEE SHEET A-6 THRU A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON G.C. TO ENCASE EXISTING BEAM EXPOSED BELOW CEILING WITH 5/8" GWB PAINTED PT-3 CEILING AT TRANSITION 1/4" = 1'-0"3 TRACK LIGHT SUPPORT DETAIL 1" = 1'-0"5 BULKHEAD DETAIL 1 1/2" = 1'-0"6 NORTH PA I N T PL A S T I C L A M I N A T E GLOSS WHITECERAMIC TILE 3x6 PREP, DINING ROOM - BUTTED TIGHT & GROUTED - DALTILE FL O O R F I N I S H MARK COLOR FINISH SCHEDULE MODEL NO.MATERIAL MANUFACTURER STYLE DESCRIPTION BA S E CE I L I N G FF-3 PL-1 WT-1 FF-5 WT-7 5038 AVALANCHEWALL GROUT KITCHEN & BATHROOMS - USE WITH WT-1, WT-2, & WT-3UNSANDED GROUT ARCTIC WHITE A P P R O V E D V E N D O R L I S T VENDOR RESPONSIBILITY FLOORING AND WALL TILE THERE WILL BE ABSOLUTELY NO ACCEPTED SUBSTITUTIONS, COLOR MATCHES OR ALTERNATIVES TO THESE PAINT AND FINISH MATERIAL SPECIFICATIONS. ALL PAINT MUST BE PER MANUFACTURER, COLOR, FINISH/SHEEN AS INDICATED IN THESE CONSTRUCTION DOCUMENTS. PLASTIC LAMINATE NERO INGOJ0720FENIX-CUSTOMER COUNTER AS NOTED. PROVIDE 6"-8" LARGER CUT IN FIELD QUARRY TILE 6" X 6" FLOOR TILE WITH 3/16" JOINTS ASHEN GRAY0T03QUARRY COVE BASE DALTILE 6" X 8" BULLNOSE INTEGRAL COVE BASE ATWB-1 ALL WALLS & MILLWORK IN PREP - BACKROOM ALABASTER7008SATIN PREP DOORS AND FRAMES, PREP SIDE OF SOFFITPT-3 AGGER GREYQUARTZ SURFACE CAESARSTONE CUSTOMER ORDER COUNTERTOPQZ-J-2 FLOORING SURFACES, INC. (NO SUBSTITUTION) CONTACT: ROB CLAPPER 401 EAST MERCURY CHAMPAIGN, IL 61822 PHONE: 217.398.1990 FAX: 217.398.9007 E-MAIL: rob@fsi-1.com DRAS CASES CONTACT: JOSH FLATTUM 880 NORTH LAKE STREET LAKE MILLS, IA 50450 PHONE: 507.402.4812 E-MAIL: josh@drascases.com COUNTERS / MILLWORK TRICORN BLACKSW6258SHERWIN WILLIAMS SEMI-GLOSSPT-7 PT-8 REALIST BEIGESW6078SHERWIN WILLIAMS SEMI-GLOSS EXTERIOR - CORNICE E.I.F.S. PT-2 DINING RM CEILINGS - OVERHEAD ITEMS 1006 SEE DESCR.FF-1 CONSOLIDECK SEE DESCR.CLEAR ASHEN GRAYQUARRY WB-2 - DALTILE 0T03 KEC DESIGN (NO SUBSTITUTION) 301 MERCURY DR. SUITE 1 CHAMPAIGN, IL 61822 PHONE: 217.356.1640 FAX: 217.356.1661 E-MAIL: projects@kecdesign.com WA L L T I L E PAINT PAINT PAINT PAINT 3/16" GROUT JOINTS - PREP FLOOR/BASE - DINING FLOOR WHEN USING FF-5 GRIND/SCRAPE FLOOR CLEAN. APPLY CONSOLIDECK LS DENSIFIER. C-1 VENDOR RESPONSIBILITY CEILING TILE --PREP & DINING - 2'x4' GYPSUM BOARD, 1/2" THICK - WHITE - VINYL SURFACE- GLOSS BLACKCERAMIC TILE 3x6 DINING ROOM - BUTTED TIGHT & GROUTEDDALTILEWT-3 BLACK BRIGHT CONCRETE FF-4 EXTERIOR - CORNICE E.I.F.S. FF-2 METROPOLITANPANARIA CERAMICA 23 3/4 x 23 3/4 INFUSED FLOOR GROUT PORCELAIN TILE DINING & RESTROOMS WHEN CONCRETE SLAB IS NOT USABLE 3/16" JOINTS MAPEI GROUT SANDED GROUT CHARCOAL- 3/16" GROUT JOINTS - DINING & RR WALL BASE TILE WB-3 TILE INTEGRAL COVE BASE DALTILE DL28 BLACK 3/16" GROUT JOINTS THROUGHOUT RESTROOMS WHEN FF-5 IS USED - SP E C I A L FI N I S H - 6 x 12 COVED BASE WT-6 GLOSS WHITECERAMIC TILE 6x6DALTILEARCTIC WHITE RESTROOM - BUTTED TIGHT & GROUTED POLISH CONCRETE TO 800 GRIT LEVEL. APPLY 2 COATS CONSOLIDECK POLISHGUARD. FINAL POLISH W/ 800 GRIT. FILL ALL EXPANSION JOINTS FLOOR GROUT BOSTIK SANDED GROUT BLACK MAPEI GROUT COUNTERS / MILLWORK MIDWEST CABINET CO., INC. CONTACT: SCOTT TETER 1674 INDUSTRIAL AVENUE OTTAWA, KS 66067 PHONE: 785.242.8181 EXT. 17 FAX: 785.242.8183 EMAIL: steter@midwestcabinet.com TRICORN BLACKSW6258SHERWIN WILLIAMS EGGSHELLPT-6 PAINT BEHIND MENU BOARD ON SOFFIT (MUST BE SATIN AND NON-LOW VOC) WT-6A 3x6ARCTIC WHITE MEN'S RESTROOM - BUTTED TIGHT & GROUTED - CUSTOM PRINTCERAMIC TILE DALTILE GLOSS WHITE WITH A POLYUREA, SEMI-RIGID JOINT FILLING COMPOUND. FOLLOW ALL MFR. GUIDELINES WESTCHESTER GRAYSHERWIN WILLIAMS EGGSHELL2849 REAL RED6868SHERWIN WILLIAMS EGGSHELLPT-5 PAINT DINNING SIDE OF SOFFIT, EXTERIOR- BOLLARDS & D-T CURB GRAY MATTERS7066SHERWIN WILLIAMSPT-4 PAINT DINNING WALLSEGGSHELL SHERWIN WILLIAMS RESTROOM DOOR FRAMES AND OTHER DOOR FRAMES WHEN IN DINNING. WC-1 "JJ" WALLPAPER WALL COVERING PROVIDED BY ARTWORK VENDOR. INSTALLED BY G.C. C-2 EXPOSED DINING ROOM PT-2WESTCHESTER GRAYSHERWIN WILLIAMS EGGSHELL2849 EQUIPMENT, FURNITURE, PLUMBING FIXTURES, AND LIGHTING DEANS GRAPHICS CONTACT: BRANDON CHRISTIE 3103 RESEARCH RD. CHAMPAIGN, IL 61822 PHONE: 217.363.1390 E-MAIL: brandonc@deans-graphics.com VENDOR ARTWORK / WALL GRAPHICS RESPONSIBILITY C-3 DINING ROOM- 2'X2' UNPERFORATED TILE - SQUARE EDGE- 5/8"NON- PAINTEDUSGCLIMA-PLUS/ #8221ASTROCEILING TILE C-4 DINING ROOM PT-2WESTCHESTER GRAY SHERWIN WILLIAMS EGGSHELL28495/8" GYPSUM BOARD TILE BASE 6X24X5/16 DL28 BLACKDALTILE DELEGATE USE AT POLISHED CONC FLOOR-3/16 GROUT JOINTS THROUGHOUT DINING AND RESTROOMS-G-1. WHEN FF-5 IS USED- USE WB-3 COVE BASE WITH TRIMBLACK WB-4 COVE FILLET STRIP #44ROPPE BLACK-USED AT RESTROOM WHEN POLISHED CONCRETE FLOOR (FF.J.1)&(WB.J-2) PL-2 PLASTIC LAMINATE 845-90 SPECTRUM REDFA C-CORE2FORMICA GLOSS CUSTOMER COUNTER AS NOTED. PROVIDE 6"-8" LARGER CUT IN FIELD PL-3 PLASTIC LAMINATE FA 949-58 -WHITE USED AT MILLWORK AND WHERE INDICATED ON PLANS EDGE-1 1MMEDGEBAND MATCH PL-1 EDGE-2 EDGE-3 P-LAM SELF EDGE 0.5MM VENEER EDGEBAND CHARTER CHARTER CHARTER 1MM PVC C-CORE2 0.5MM - - - PLANKED URBAN OAK MATCH NERO INGO BIRCH VENEER FENIX EDGES CUSTOMER ORDER COUNTERTOP EDGE CUSTOMER ORDER COUNTER ARTWORK OR APPROVED INSTALLER FF-6 DELEGATE BLACKDALTILETILE MATTE FINISH 12X24, 6X24 DL28 BLACK3X24 BULLNOSE USED AT PLATFORM FLOOR UNDER DISPLAY COOLER IN MILLWORK BY GC BULLNOSE AT EXPOSED EDGE BRICK BR-1 BRICK ROSEWOOD BLENDBELDEN BRICK (IF APPLICABLE TO EXTERIOR SCOPE)MORTAR TO BE STANDARD GREYJUMBOA-06-14 E.I.F.S EIFS-1 E.I.F.S --(IF APPLICABLE TO EXTERIOR SCOPE)EXTERIOR CORNICEFINE FINISH- WOOD WD-2 3/4" VENEER PANEL BIRCH VENEERMILLWORK VENDOR PICKUP SHELVESMDF CORESHOP STANDARD FRP-1 FIBERGLASS S-100 - S/2/S SMOOTH FINISH WHITEMARLITE REINFORCED PLASTIC BACK-OF-HOUSE WALLS - PREP SIDE OF MILLWORK WHEN SITE BUILT OUTSIDE CORNER TRIM MUST BE 1-1/2" X 1-1/2" NON-INTEGRATED FRP-2 DECORATIVE FRP SYMMETRIX SUBWAY GLOSS WHITE BRICKMARLITEBRICK PANEL SYSTEM WALL FINISH OPTION(IF APPLICABLE) SMARTSEAM PATTERNWHITE W/GREY GROUT LINES FRP-3 DECORATIVE FRP SYMMETRIX SUBWAY GLOSS BLACK BRICKMARLITEBRICK PANEL SYSTEM WALL FINISH OPTION(IF APPLICABLE) SMARTSEAM PATTERNBLACK BRIGHTW/GREY GROUT LINES SAFETY RED-PITTSBURGH SEMI-GLOSS EXTERIOR - BOLLARDS & D-T CURBPT-9 PAINT FI B E R G L A S S PA N E L S REAL RED DELEGATE BLACK D A-3 D A-3 D A-3 D A-3D A-3 D3 A-3 E A-3 E A-3FF-1 103 UNISEX 6 FF-1 100 DINING 6 C A-3 C A-3 C A-3 C A-3 C A-3 C A-3 C A-3 C A-3 C A-3 C A-3 C A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3 G A-3G A-3 G A-3 G A-3 G A-3 101 PREP FF-4 FF-3 102 BACKROOM FF-4 FF-3 4 COUNTERS TO BE INSTALLED ON THE SUBSURFACE PRIOR TO THE TILE INSTALLATION, SEAL CONCRETE BELOW CABINETS.1 7 9 1 A-6 2 A-6 3 A-6 4 A-6 5 A-6 6 A-6 1 A-7 2 A-7 3 A-7 4 A-7 5 A-7 6 A-7 7 A-7 8 A-7 9 A-7 10 A-7 11 A-7 12 A-7 13 A-7 16 A-7 18 A-7 14 A-7 17 A-7 19 A-7 20 A-7 A A-3 15 A-7 18 1010 13 3 3 19 5/8" MOLD RESISTANT GYP. BD., ASTM C36 OR C630 IN DINING RM. AND CEMENT BACKER BD. UP 12" IN WORK AREAS AND RESTROOMS. FRP-1 COVE BASE- INTEGRAL TO FLOOR TILE TYP WITH BULLNOSE AT TOP WB-1 RESTROOM BASE & WALL TILE BACKROOM BASE & FRP G 112" = 1'-0" FF-4 SEALANT SEE CEILING PLAN CERAMIC COVE BASE (WB-1, PURITAN GRAY) INSTALLED ON TOP OF WALL TILE (INTEGRAL COVE BASE BULLNOSE) 5/8" MOLD RESISTANT GYP. BD., ASTM C36 OR C630 IN DINING RM. AND CEMENT BACKER BD. UP 12" IN WORK AREAS. CERAMIC TILE - SEE ELEVATIONS FOR COLORS TI L E T O E X T E N D T O C E I L I N G WB-1 WALL TILE EXTENDS TO CEILING KITCHEN BASE & WALL TILE C 112" = 1'-0" FF-4 SE E E L E V A T I O N S F O R T I L E H E I G H T 6"x24"X5/16" TILE BASE POLISHED SEALED CONCRETE CERAMIC TILE - SEE ELEVATIONS WB-2 SE E E L E V A T I O N S F O R T I L E H E I G H T 5/8" GYP. B.D. (PRIME) BULLNOSE TILE AT TOP ROW 5/8" GYP. B.D. DINING RM WALL TILE D3 112" = 1'-0" FF-1 SEALANT AT FLOOR TOP OF TILE SEE ELEVATIONS RESTROOM BASE & WALL TILE PORCELAIN TILE - BULLNOSE - INSTALLED ON TOP OF WALL TILE POLISHED SEALED CONCRETE CERAMIC TILE - SEE ELEVATIONS WB-2 SE E E L E V A T I O N S F O R T I L E H E I G H T 5/8" GYP. B.D. (PAINT AS REQUIRED) BULLNOSE TILE AT TOP ROW 5/8" GYP. B.D. DINING RM WALL TILE D2 112" = 1'-0" BASE TILE CUT TO 1" BEHIND SODA CABINET TI L E S T O T H E C E I L I N G I N R E S T R O O M S POLISHED SEALED CONCRETE RESTROOM BASE & WALL TILE E 5/8" MOLD RESISTANT GYP. BD., ASTM C36 OR C630 IN DINING RM. AND CEMENT BACKER BD. UP 12" IN WORK AREAS AND RESTROOMS. WT-6 WB-2 COVE BASE - ROPPE - #44 FILLET STRIP - COLOR: BLACK 112" = 1'-0" BULLNOSE - INSTALLED WB-4 FF-1FULL BED OF SEALANT SEE CEILING PLAN COVE BASE- INTEGRAL TO FLOOR 6"x24"X5/16" TILE BASE POLISHED SEALED CONCRETE CERAMIC TILE - SEE ELEVATIONS WB-2 SE E E L E V A T I O N S F O R T I L E H E I G H T 5/8" GYP. B.D. (PAINT PER ELEVATIONS) BULLNOSE TILE AT TOP ROW 5/8" GYP. B.D. DINING RM WALL TILE D 112" = 1'-0" FF-1 SEALANT AT FLOOR TOP OF TILE PAINT TRANSITION LINE SEE ELEVATIONS SEE ELEVATIONS 5/8" GYP. B.D. (PT-2) 7 3/8" 7 3/8" 1 1 / 4 " 3' - 6 " 1/2" x2" HORZ BATTEN QZ.J-2 FRP-1 ON 3/4" SUBSTRATE SENT LOOSE- MY MW VENDOR BASE BY MW VENDOR DINING RM / PREP - HALF WALL A 112" = 1'-0" PREP SIDE DINING SIDE FF-4 FF-1 WB-1 BY MW VENDOR DIE WALL FURNISHED BY MW VENDOR INSTALLED BY GC 1/2" x 2" HORIZONTAL BATTEN 4" P-LAM P PANEL PT BASE BY MW VENDOR SECURE TO SLAB BY GCSHIM AS NEEDED 1 7/8"3 7/8"1 5/8" 5 1/4" A-3 FLOOR FINISH PLAN AND SCHEDULE FLOOR FINISH PLAN 1/4" = 1'-0"1 S Y M B O L S L E G E N D X X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X X DOORS X CEILING FINISHES SEE SHEET A-6 THRU A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X K E Y E D N O T E S 15 1 2 3 4 6 7 START BULLNOSE QUARRY BASE TILE ON BOTH SIDES OF PREP OPENING. CUT FIRST ROW OF QUARRY FLOOR TILE TO WIDTH OF BULLNOSE BASE TILE. NO FLOOR TILE UNDER MOP SINK. PROVIDE (2) COATS SEALER AT ALL EXPOSED CONCRETE. NO FLOOR TILE UNDER COOLER/ FREEZER. PROVIDE (2) COATS SEALER. OUTLINE OF MILLWORK. (NO FLOOR TILE). GROUT IN ALL PREP FLOOR TILE AREAS SHALL BE FF-3 (TYP.) GRIND/SCRAPE FLOOR CLEAN. APPLY CONSOLIDECK LS DENSIFIER. POLISH CONCRETE TO 800 GRIT LEVEL. APPLY 2 COATS CONSOLIDECK POLISHGUARD. FINAL POLISH W/ 800 GRIT. FILL ALL EXPANSION JOINTS WITH A POLYUREA, SEMI-RIGID JOINT FILLING COMPOUND. FOLLOW ALL MFR GUIDELINES. PROVIDE FLOOR TRANSITION - INSTALL SCHLUTER RENO-RAMP - ALIGN LOW END OF RAMP TO BE FLUSH WITH MILLWORK - FLOAT AS REQUIRED. CUT WALL BASE TILE (BEHIND SODA CAB'T ONLY) TO 1" TALL TO ALLOW SODA CAB'T TO SIT FLUSH AGAINST WALL TILE. OUTLINE OF THE SODA CABINET. DO NOT INSTALL BASE TILE ON SODA CABINET. FLOOR TRANSITION LINE - INSTALL SCHLUTER SCHIENE TO CAP END OF QUARRY TILE. SEE SHEET A-3.1 FOR CORE DRILL LOCATIONS. BASE TILE IS TO BE CUT TIGHT TO FIT AROUND BASE OF WALL HUNG TOILETS. DO NOT INSTALL TOILETS ON TOP OF BASE TILE. SEE SHEET A-10 FOR CORE DRILL LOCATION. . BASE TILE MUST NOT BE INSTALLED BETWEEN SS SODA CABINET AND WALL. EXTEND SUBWAY TILE TO FLOOR. TILE (WT-4) ON END OF MILLWORK TO BE INSTALLED AFTER CASH COUNTER (ABOVE) AND/OR SODA CABINET(ABOVE AND BELOW, IF APPLICABLE) SUBWAY TILE TO BE INSTALLED ABOVE COUNTER ONLY EXTEND SUBWAY TILE TO 7'-6" BEHIND SODA CABINET - SEE ELEVATIONS FOR FULL EXTENT HALFWALL MILLWORK BY MILLWORK VENDOR PROVIDE FLUSH TRANSITION - FLOAT AS REQUIRED FLOOR TILE TO EXTEND BENEATH MILLWORK TO WALL FRAMING ADD BASE TILE. NO WB-3 INSTALLED ON TOP OF PLATFORM. 9 10 11 13 14 JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON NOT USED NORTH 5 8 12 16 17 G E N E R A L N O T E S 1.ALL WALLS BEHIND MILLWORK SHALL HAVE FINAL WALL FINISH PRIOR TO INSTALLATION. ALL FLOORING FINISH MATERIAL SHALL BE INSTALLED AFTER MILLWORK INSTALLATION. 2.COORDINATE WITH PLUMBING DRAWINGS FOR ALL FLOOR DRAINS AND CLEAN OUT LOCATIONS. 3.ALL FLOOR JOINTS AND QUARRY TILE JOINTS SHALL BE 3/16". 4.ALL CABINETS (EXCEPT STAINLESS STEEL SODA CABINET) MUST BE INSTALLED ON SUBSURFACE PRIOR TO TILE. 5. WHEN FLOOR TILE MUST BE INSTALLED ON WOOD SUBSTRATE, INSTALL 1/2" DUROCK IF NOT PRESENT. IF EXISTING ENSURE IN LIKE NEW CONDITION OTHERWISE REPLACE APPLICABLE SHEETS. NOT USED NOT USED NOT USED NOT USED NOT USED NOT USED 18 NOT USED NOT USED NOT USED NOT USED 19 101 PREP 100 DINING 13 131212 22 75 16D 16 39 39 2919 2833 15A 29 19 28 33 14A 8 3 2A 2 14F 14F 71 8A 14.5 27 71 39 8 18 50 49 5B 911 3 35 310 3 3 14K 33 30.2 33 33 33 33 30.3 33 33 33 40 58 16A 102 43 14A 50 107A 108A 76 77 7879 78 72A 73 72A 73 24H 24E 24H 24H 24G 84 83 85 86 82 87 81 97 91 92 87 96 88 89 90 99 42 1 93 23 23C 454 23C 23C 23C 23C 23C 23C 23A 23D 23D 23D 23D 24M 24M 41 41 41 16B 53 53 53 53 FE 7 FE 7 41 6 54 55 24N 5 11B 38A 38 32A 32A 32A 36 36F 68 2 6 FE 7 4 34 102 BACKROOM 103 UNISEX FIXTURE & EQUIPMENT PLAN NOTES:JJ EQ U I P . N O QU A N T I T Y EQUIPMENT NAME FR A N C H I S E E AVAYA 2554 FEATURE PHONE DRIVER SHELF ICE/BEVERAGE UNIT SNEEZE GUARD CUP DISPENSERS SIDE LOADING BREAD RACK 91" REFRIG. PREP TABLE AND COUNTERTOP STYLE DESK AND SHELVES 34" HIGH CASH MILLWORK & COUNTER 12"x 91" S.S. OVERSHELF BAG-N-BOX CARBONATE STOR. BULK C02 SYSTEM SURFACE MOUNT FILL BOX EL E C . R E Q . ME C H . R E Q . PL U M B . R E Q . METRO SEAL RACKS FOR COOLER DUNNAGE RACKS FOR FREEZER STANDING COUNTER POST CUNO #15 WATER FILTER SOFFIT MOUNTED MENU BOARD (30" X 120") REFER TO ELECTRICAL DRAWINGS 120V (INSTALL DATA/POWER OUTLETS INSIDE CABINET) REFER TO CABINET DRAWINGS PROVIDED BY KEC EQUIPMENT - SEE 4/A-1.1 120V - CORD AND PLUG (C&P) (INSTALL OUTLET IN CABINET) PROVIDE SOLID BLOCKING- SEE ELEVATIONS & DETAIL B/A-10 REFER TO PLUMBING DRAWINGS 31"-24"-31" CONFIGURATION 1/2" C.W. 120V - 1/2 HP - CORD & PLUG PROVIDE IN WALL BLOCKING TRASH RECEPTACLE BATHROOM ACCESSORIES - NEW REFER TO PLUMBING DRAWINGS AND SHEET A-5 120 VAC, 60 HZ, 2 AMPS - VERIFY EXACT LOCATION. MANUFACTURER CO N T R A C T O R LA N D L O R D AVAYA MILLWORK VENDOR CUSTOM KEC KAIRAK - QUANTUM - - - NEXEL NEXEL UNIVERSAL CUNO - BOBRICK - ZURN 2 2A 3 4 5 5B6 8 9 10 11 12 13 14A 16 16A 16B 18 19 22 23C 23D 27 29 33 34 35 36F 39 40 41 42 43 44 45 3/8" COND. DRAIN - 1" BIN DRAIN PROVIDE IN WALL BLOCKINGSAN JAMAR28 F I X T U R E A N D E Q U I P M E N T S C H E D U L E SEE SHEET A-9.1 VERIFY EXACT LOCATION IN FIELD ENSURE EASY ACCESS TO THIS FILTER CARTRIDGE MOUNT TO WALL- TOP @ 8'-0" A.F.F..- SEE PLUMBING SHEETS HOSHIZAKI1 DOOR REACH - IN REFRIGERATOR W/ 10 PANS 115V (RECEPT. @ 72" A.F.F.) 120V - CORD AND PLUG (C&P)-(INSTALL OUTLET ON WALL NEAR MACHINE. SEE SHEET E-1) COKE TO PROVIDE S/S STAND 8' x 7' x 8'-6" TALL WALK-IN FREEZER W/ ELECTRIC DOOR 14' x 7' x 8'-6" TALL WALK-IN COOLER W/ ELECTRIC DOOR 23 23A ICED TEA BREWER SEAMLESS STAINLESS STEEL ICED TEA DISPENSER 120V - CORD AND PLUG (C&P)-(INSTALL OUTLET IN CABINET) 1800 WATTS, 15 AMPS, 5-15 RECEPTACLE49 50 POS TERMINAL STAINLESS 60"X30" S.S. TABLE STAINLESS STEEL BOX CONSTRUCTIONPART # 9722279 BRASS FILL FITTING. STAINLESS HAND SINK w/ FAUCET - UPDATE 38 HCS-2 COAT RACK GAMCO OUTDOOR DRIVE-THROUGH MENU BOARD OUTDOOR DRIVE-THROUGH SPEAKER POST AND MIC 120 VAC, 60 HZ, 2 AMPS - VERIFY EXACT LOCATION. SEE D/A11 SEE B/A11 ADA ACCESSIBLE CHAIRS MOP RACKS STAINLESS STEEL CORNER GUARDS KEC ON OUTSIDE CORNERS OF TILE IN PREP AREA BIZERBA#GSP-HD ELECTRIC SLICER BUNN-O-MATIC BUNN-O-MATIC UNDER COUNTER TRASH RECEPTACLE DELFIELD SS SODA CABINET - 59" FINISHED DELFIELD 1475723 CORE DRILLED - SEE SHEET A-10 32A BARSTOOLS (MOVABLE) 208/220V/1PH HP-WIRE TO J-BOX 208/220V/1PH HP-WIRE TO J-BOXKOLPAK KOLPAK SPEAKER53 VOLUME CONTROL54 2 4 3 1 7 1 3 2 1 1 8 3 2 2 1 4 7 1 1 1 2 1 1 2 2 2 1 1 1 1 1 1 6 1 2 55 RECEIVER 1 1 1 2 1 4 1 1 MUST BE MOUNTED AT +10'-0" AFF. SEE COM-1. MUST BE AT MANAGER'S DESK. SEE COM-1. MUST BE AT MANAGER'S DESK. SEE COM-1. 8A 1 FREESTANDING ICE/BEVERAGE UNIT LANCER 2300 SAN JAMAR 14F 2 STAINLESS 24"x30" S.S. TABLE 120V-1/2 HP 15A 1 4 DECK OVEN/PROOFER COMBINATION 2 24E 18"x48" WIRE SHELVING UNITS1 24G 18"x60" WIRE SHELVING UNITS1 24H 18"x72" WIRE SHELVING UNITS3 36 1 1'-6" X 6'-0" X 42" H COMMUNITY TABLE REFER TO CABINET DRAWINGS AND SHEET A-10 1'-6" X 4'-0" X 42" H COMMUNITY TABLE REFER TO CABINET DRAWINGS AND SHEET A-10 PIPER PRODUCTS 208V - 3 PH - LOCK OUT BREAKER ELKAY ADA STANDING COUNTER POST 38A 2 CORE DRILLED - SEE SHEET A-10 14.5 1 STAINLESS 96"x30" SLICER TABLE KEC RUBBERMAID - - - - - S3ET CLASSICS - OPEN TOP - 94L/25G KEC KEC KEC KEC 14K 1 STAINLESS 24"x60" S.S. DELIVERY TABLE JOHN BOOS 30.2 LOW TABLE FOR 4 (42" x 24")2 KEC QUANTUM QUANTUM QUANTUM JOHN BOOS JOHN BOOS JOHN BOOS KEC KEC KEC KEC KEC 42" HIGH HALF WALL MILLWORK REFER TO CABINET DRAWINGS5B1 16D CARBONATOR COKE2 SEE DETAILS ON A-1.1 AND P-1 120V-1P - WIRE TO J-BOX 120V-1P - WIRE TO J-BOX SOAP DISPENSER- INTERNATIONAL 32 PAPER TOWEL DISPENSER -T1755TBK 58 PICKUP SHELF 36" x 12"1 KEC 11B TABLE MOUNTED CUP DISPENSERS2 SAN JAMAR IDW WATER COOLER BELOW FRONT COUNTER - 115VIDW PROVIDE BLOCKING FOR SHELVING BRACKETS AND WIRE GRID BRACKETS, SEE ELEVATIONS METRO685'-0"x14" METRO WIRE SHELVING WITH 33PDF POST & BRACKET ASSEMBLY1 MILLWORK VENDOR MILLWORK VENDOR N12DIPHSVE-R45-751 BR MOMENTS MIRROR FINISH. REQUIRES BASE BY G.C. NELSON72ADIPPING CABINET 67"W x 30"D 12 FACINGS2 90022732BUILD-ITDIPPER WELL FOR DIPPING CABINET T30HSP(LEFT HAND HINGE) 1 SECTION, 1 DOOR, PERF. VALID.75 1 GLOBALHARDENING CABINET 72"W x 31"D BR000452761STAINLESS STEEL CAKE PREP TABLE MIDDLEBY FABRICATION 20030771TUB CUTTER KIT BUILD-IT 78 2 36" W FLAT SOLID SHELVING METRO 1436FS 79 1 STAND MIXER KITCHEN AID KSM8990WH 8 QUART 81 1 BANANA TREE BUILD-IT 20045 82 1 SCALE DETECTO DM15 83 2 WARMER SERVER 82155 CUSTOM PUMP FOR HOT FUDGE AND CARAMEL PRALINE PRODUCTS 84 1 WAFFLE MERCHANDISER LD 130-204 W/ DOOR AND REMOVABLE SHELVES PLASTICS 85 1 WAFFLE CONE BAKER KIT COBATCO MD-10INC 86 1 SINGLE DIPPING CHOCOLATE WARMER 92000SERVER PRODUCTS 87 4 COUNTERTOP LID DISPENSER CTLD-22 STAINLESS STEELDISPENSE- RITE 88 1 DAIRY AND SYRUP DISPENSER AC220-FP-8 SURE SHOT REFRIGERATEDAC DISPENSING 89 1 CUP RACK 6019277WASSERSTROM 90 1 ICE CADDY ICS100L191 GRANITE GREYCAMBRO 91 1 WIRE LID HOLDER WR-4DISPENSE- RITE 92 1 VERTICAL WIRE RACK CUP ORGANIZER WR-CT-4DISPENSE- RITE 93 1 SUNDAE CENTER MST-28 27 1/2"W x30"D x 37"H, WITH CASTERSTURBO AIR 96 1 UNDER COUNTER REFRIGERATOR MUR-28-N-1CTURBO AIR 97 1 60" WORK TABLE DB306034WT WITH CASTERS AND SHELVINGMETRO 99 1 DUMP SINK W/ DRAIN SHELF FRANKE LEFT HAND 18019858 102 TWO GLASS DOOR MERCHANDISER1 TURBO AIR TGF-49-B-N 107A STAINLESS LEG 28"D4 STAINLESS LEG-S-28 108A ICE MACHINE1 METRO D-970 71 MERRYCHEF CONNEX 12 WELBILT2 24M 24"x60" WIRE SHELVING UNITS3 QUANTUM 24N 24"x36" WIRE SHELVING UNITS3 QUANTUM 5' - 0 " M A X . 44 45 44 SEE SHEET A-11 AND A-12 FOR ACTUAL LOCATION OF DRIVE THRU MENU/ ORDER BOX A-4 EQUIPMENT PLAN AND SCHEDULE K E Y E D N O T E S 1 2 3 4 5 6 7 ELECTRICAL PANELS. A.D.A. ACCESSIBLE SEATING. HAND SINK WITH SOAP AND PAPER TOWEL DISPENSER WITH 6" S/S SPLASHGUARDS EACH SIDE. CONTRACTOR TO PROVIDE S/S CLOSURE PIECES TO SEAL AIR SPACE BETWEEN WALL AND COOLER/FREEZER. PROVIDE CONTINUOUS CLEAR SEALANT. WALK-IN COOLER/FREEZER NOTES: -SEE EQUIPMENT SCHEDULE FOR WALK-IN BOX HEIGHT. -ALL WALK-IN DOORS WILL HAVE INTERIOR/EXTERIOR 36" HIGH DIAMOND TREAD KICK PLATES. -ALL WALK-INS WITH FLOORS WILL HAVE INTERIOR DOOR RAMPS AT ANY DOORS (OTHER THAN THE FREEZER DOOR IN A SHOTGUN APPLICATION). -THE STAINLESS STEEL FINISH OPTIONAL TO BE DETERMINED BY FRANCHISEE. -ALL LIGHT FIXTURES WILL BE L.E.D. WHEN A SEPARATE CEILING MOUNTED FIXTURE IS REQUIRED, IT TOO WILL BE L.E.D. HANG LADDER - VERIFY WITH FRANCHISEE. FIRE EXTINGUISHER SEE 1/A-4. (2) P.O.S. TERMINALS AT THE DRIVER'S SHELF. DRIVE THROUGH CANOPY PROVIDED BY OWNER, GC TO INSTALL G E N E R A L N O T E S 1.PORTABLE FIRE EXTINGUISHERS SHALL BEAR THE LABEL OF AN APPROVED AGENCY, BE AN APPROVED TYPE, AND BE INSTALLED IN A LOCATION VISIBLE AND ACCESSIBLE TO THE OCCUPANTS. FINAL LOCATION BY FIRE PREVENTION BUREAU. PER I.F.C. 906.1 2.PORTABLE FIRE EXTINGUISHERS HAVING A GROSS WEIGHT NOT EXCEEDING 40 LBS. SHALL BE INSTALLED SO THAT ITS TOP IS NOT MORE THAN 5' ABOVE THE FLOOR. PORTABLE FIRE EXTINGUISHERS HAVING A GROSS WEIGHT EXCEEDING 40 LBS. SHALL BE INSTALLED SO THAT ITS TOP IS NOT MORE THAN 3.5' ABOVE THE FLOOR. THE CLEARANCE BETWEEN THE FLOOR AND THE BOTTOM OF INSTALLED HAND-HELD EXTINGUISHERS SHALL NOT BE LESS THAN 5". 3.PROVIDE MIN. (2) TYPE 2A 10BC FIRE EXTINGUISHERS WITH MAX TRAVEL DISTANCES OF 75' (150' O.C.) MOUNTED BETWEEN 5" AND 5' AND NOT PROTRUDE MORE THAN 4" INTO A CIRCULATION PATH WHEN LEADING EDGE BETWEEN 27" AND 80" A.F.F. HARDWARE TO F.E.C. SHALL BE AT ACCESSIBLE HEIGHTS / LOCATIONS. 4.THE MODULAR MILLWORK COMPONENTS ARE CONSTRUCTED OFF SITE BY AN APPROVED VENDOR AND ARE INSTALLED BY THE G.C. LOCATE MODULAR COMPONENTS AS INDICATED. 5.TOILETS, URINALS, HAND SINKS, 3-COMPARTMENT & PREP SINKS, MOP BASIN AND PERMENANT COUNTERS AND CABINETS MUST BE SEALED TO FLOORS/ WALLS WITH A SILICONE CAULK SEAL. 6.PROVIDE VAPOR PROOF FLUORESCENT LIGHTING IN COOLER & FREEZER MAINTAIN AIR SPACE PER MFR.'S RECOMMENDATION. 7.IF HAND SINKS HAVE SPRING-LOADED FAUCETS, THEY WILL RUN FOR A MINIMUM OF 15 SECONDS 8.GENERAL CONTRACTOR TO ENSURE THAT ALL CO2 LINES ARE CONCEALED WITHIN WALLS AT TIME OF IN WALL ROUGH-INS. CONFIRM W/ CO2 COMPANY IF LINES RECESSED IN WALLS MUST BE RUN THROUGH CONDUIT. CONTRACTOR SHALL FIELD VERIFY EXACT ROUTING PRIOR TO BID. 9.ALL OUTSIDE TILE CORNERS IN PREP ARE TO HAVE SS CORNER GUARDS INSTALLED. 10.HOT WATER AND DRAIN PIPES EXPOSED UNDER SINK MUST BE INSULATED TO PROTECT AGAINST CONTACT. S Y M B O L S L E G E N D X X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X X DOORS X CEILING FINISHES SEE SHEET A-6 THRU A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X EQUIPMENT PLAN 1/4" = 1'-0"A FIRE EXTINGUISHER 1/2" = 1'-0"1 8 JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON NOTE: LOCATION OF C02 FILL BOX TO BE COORDINATED IN FIELD. VERIFY WITH OWNER, G.C., AND LANDLORD NORTH 103 UNISEX A-5 1 HANDICAP SIGNAGE, REF. TO N/A-5 7 6 9 2 4 1 3 8 5 5 12 3 NOTES: 1. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND 2. RAISED CHARACTERS SHALL BE 48" MIN. ABOVE THE FLOOR MEASURED TO THE BASELINE OF THE LOWEST RAISED CHARACTER AND 60" MAXIMUM ABOVE THE FLOOR, MEASURED TO THE BASELINE OF THE HIGHEST RAISED CHARACTER. 3. SYMBOLS ARE TO BE DISTINCTLY DIFFERENT FROM THE DOOR IN COLOR AND CONTRAST 4. PROVIDE ROOM IDENTIFICATION SIGN ON LATCH SIDE OF DOOR LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32" MIN. AND SHALL BE A MIN. OF 5/8" TALL. LETTERS SHALL BE SANS-SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE 5. LOCATE RAISED AND BRAILLE CHARACTERS, SIGNS ON THE WALL NEAREST TO THE LATCH SIDE OF THE DOOR CL ADA SIGN ADA ROOM IDENTIFICATION SIGN LATCH SIDE OF DOOR GRADE 2 BRAILLE1/4" THICK SIGNS 6" WT-6 WT-7 TOILET INTERIOR ELEVATION E 8'-0" A.F.F. CEILING HT. TYP. WB-2 FF-2 6X6 WHITE WALL TILE THROUGHOUT THE ENTIRE RR WALLS AND DOWN BEHIND THE BASE TILE, TYPICAL 1/2" = 1' 2740 TOILET PAPER DISPENSER BOBRICK COLOR/STYLE T O I L E T A C C E S S O R Y S C H E D U L E MODEL NO.ACCESSORY MANUFACTURER SIZE/REMARKS INTERNATIONAL 32SOAP DISPENSER UPDATE MIRROR AT TOILET LAVATORIES BOBRICK ACCESSIBLE GRAB BARS LAVATORY WALL HUNG INSULATION TRUEBRO WHITE WHITEHANDI LAV-GUARD SEAT NOTE: ALL TOILET ACCESSORIES SHALL MEET ALL REQUIREMENTS OF THE ANSI 117 ACCESSIBILITY GUIDELINES AND ALL LOCAL CODE REQUIREMENTS. (800) 340-5969 WHITE 1 1/2"Ø x 42" LONG & 1 1/2"Ø x 36" LONG & LOCATED 35" TO TOP OF GRAB BAR AFF w/ NON-SLIP SURFACE. INSTALL PER PLAN ELEVATIONS. PROVIDE WALL SUPPORT BLOCKING TO ALLOW BARS TO SUPPORT 250 POUNDS OF FORCE APPLIED IN ANY DIRECTION. GRAB BAR MUST BE 1 1/2" CLEAR, FROM FINISHED FLOOR. INSULATE THE P-TRAP AND ANGLE VALVES w/FULLY MOLDED INSULATION KIT PER A.D.A.A.G. REQ'TS 1 2 3 4 5 6 7 9 150 SERIESVERTICAL GRAB BAR GAMCO NO SUBSTITUTIONS ON ANY FIXTURES #B-165 1830 18" x 30"- SHIM AS REQUIRED - PROVIDE FULL PERIMETER CAULKING ----SEE PLUMBING SHEETS 18" VERTICAL - PROVIDE BLOCKING AS REQ'D PROVIDE BLOCKING AS REQ'D SEE PLUMBING SHEETSWHITE----WATER CLOSET FLOOR MOUNTED 8 ----SEE PLUMBING SHEETS 150 SERIESGAMCO WALL MOUNT BK W/ PUSH BUTTON CHROME TRIM PROVIDE BLOCKING AS REQ'D T1755TBKPAPER TOWEL DISPENSER SAN JAMAR PROVIDE BLOCKING AS REQUIREDBK WALL MOUNT CLG. HEIGHT 8'-0" A.F.F. SEE TEMPLATE "E" FOR WALL FINISH 34 " M A X . 15" MIN. 29 " M I N . 27 " C L R . 6 4 7 40 " M A X . TO R E F L E C T I V E SU R F A C E 2 1 5 3 CL 16"-18" 35 " T O T O P OF G R A B B A R 2'-0"1'-0" 4' - 1 0 " 1' - 5 " 8 CLG. HEIGHT 8'-0" A.F.F. SEE TEMPLATE "E" FOR WALL FINISH CLG. HEIGHT 8'-0" A.F.F. SEE TEMPLATE "E" FOR WALL FINISH 3'-6" 5 33'-4" 3' - 4 " 1' - 6 " 35 " T O T O P OF G R A B B A R 1'-0" 7"-9"2'-7" 1' - 5 " 1 19 " M A X . 8 CLG. HEIGHT 8'-0" A.F.F. SEE TEMPLATE "E" FOR WALL FINISH 9 48 " SI D E A P P R O A C H 6 7 4 2 1. SEE SHEET A-6 TO A-8 FOR ALL WALL FINISHES. 2. SEE SHEET A-1 FOR WALL LEGEND & NOTES. 3. LAVATORY MIRRORS TO BE MOUNTED SO THAT REFLECTING SURFACE IS 40" MAX. ABOVE THE FLOOR. 4. RESTROOMS SHALL HAVE PERMANENT ROOM IDENTIFICATION ADJACENT TO PULL SIDE OF DOOR 60" A.F.F. TO CENTER OF SIGN. PER A.D.A. REQUIREMENTS. SEE SHEET A-5. 5. PROVIDE FIRE TREATED WOOD BLOCKING AT ALL GRAB BAR AND ACCESSORIES LOCATIONS. 6. WALL TILE TO BE BUTTED TIGHT, THEN GROUTED. 7. REFERENCE THE INSTRUCTIONS GIVEN IN THE JIMMY JOHN'S BUILD OUT MANUAL WHEN LAYING OUT WALL TILE 8.WALL BASE TO BE CUT TO FIT TIGHT AROUND TOILET. TOILET IS NOT TO BE INSTALLED ON TOP OF BASE TILE FF-2. 9.REFER TO JJ's BLOCKING CHECKLIST IN BUILD-OUT MANUAL FOR ADDITIONAL MEASUREMENTS AND DETAILS 8.SILICONE TOILET TO FLOOR USING CLEAR SILICONE. A-5 RESTROOM PLAN AND ELEVATIONS K E Y E D N O T E S G E N E R A L N O T E S S Y M B O L S L E G E N D 1 2 3 5'-0" REQUIRED A.D.A. TURNING RADIUS. 30"x48" REQUIRED A.D.A. CLEAR ACCESS. 56"x60" REQUIRED A.D.A. CLEAR ACCESS. X X X KEY NOTES WALL DECORS- FINISHES FLOOR FINISHES EQUIPMENT - X X DOORS X CEILING FINISHES SEE SHEET A-8 NOTE: SEE SHEET A-3 FOR ALL FINISHES SEE SHEET A-4X ADA SIGNAGE DETAIL 1/4" = 1'-0"N ENLARGED PLAN 3/8" = 1'-0"A JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON UNISEX TOILET 3/8" = 1'-0"1 27" DRY DOOR 27" DRY DOOR PROVIDE REMOVABLE SHELF TO BE MOUNTED ON LEFT OR RIGHT OF INTERIOR SIDE S/S END FRONT ELEVATION S/S TOP 1" CL E A R S/S END 3 1/2" MULLION NOTCH AS REQUIRED TO HOLD 27" DOOR1' - 2 1 / 2 " S/S FRONT 2' - 9 " FLANGED FEET MOUNTED FLUSH WITH END OF UNIT- SECURED TO FLOOR 52 1/2"3 1/4"3 1/4" 15 3 / 4 " 12 3 / 4 " 7 3/4" PROVIDE S/S INTERIOR ON 3-SIDES WITH OPEN BASE TO FLOOR PROVIDE TOP BRACING FOR BEVERAGE DISPENSER BY OTHERS REMOVABLE SHEVES PROVIDE S/S INTERIOR ON 3-SIDES WITH OPEN BASE TO FLOOR 31 1 / 2 " 7 3/4" S/S ENDS/S END 59" TOP VIEW CONTRACTOR MUST FASTEN SODA CABINET LEGS TO FLOOR USING HOLES IN LEGS 1' - 2 1 / 2 " 4" TOP BRACING SIDE 1' - 2 1 / 2 " 1" CL E A R TOP BRACING SIDE 2' - 9 " 2' - 9 " 1" CL E A R S/S ENDS/S END 6"1'-8 1/4"6"1'-8 1/4" 4" FLANGED FEET SECURED TO FLOOR S/S BACK EXTENDED 1" FROM FLOOR S/S TOP REAR ELEVATION S/S ENDS/S END 1" CL E A R PROVIDE REMOVABLE SHELF TO BE MOUNTED ON LEFT OR RIGHT OF INTERIOR SIDE 1' - 2 1 / 2 " 2' - 9 " FLANGED FEET MOUNTED FLUSH WITH END OF UNIT- SECURED TO FLOOR (3) J-BOXES WITH BLANK COVERS FOR RECEPTACLES BY OTHERS. FIELD CONNECTION BY OTHERS S/S WAINSCOT S.S. END S/S ENDS AND BACK TO BE ONE PIECE WITH TOP PLACED ON AND WELDED TO MINIMIZE VISIBILITY OF WELDS 42" X 24" REMOVABLE PANEL SUPPORT CLIPS FOR REMOVABLE PANEL S/S EXTERIOR BACK WELDED IN PLACE WITH ADDTIONAL SUPPORT BRACE ADHERED TO SS BACK (2) 6" DIA. HOLES WITH (2) STAINLESS STEEL GROMMET INSTALLED BY DELFIELD DO NOT CUT INTO TOP OF STAINLESS STEEL SODA CAB'T TO ROUTE SYRUP OR WATER LINES 1 1 / 4 " 4" 1'-1" 1 1 / 4 " SF-1 FRONT ELEVATION B1 SECTION B2 B2 A-10 4" SF-1 5"5" 10 " 10 " "THE ORIGINAL GRANITE BRACKET" (https://originalgranitebracket.com) - 12"x10"(10" LEG VERTICAL) INSTALL BLOCKING AT BRACKETS 3' - 5 1 / 2 " 1 1 / 4 " 2'-6" 6"6" 4' - 3 " 4' - 1 0 1 / 2 " 5' - 3 1 / 2 " 1'-3"1'-3" (2) PHONE (2) DATA (4) IG POWER 10 1 / 4 " 1' - 6 " 1' - 6 " 1' - 6 " IF C E I L I N G M O U N T E D - F I E L D V E R I F Y E X A C T H E I G H T 8" 6" 6" 2" 2'-10" 2" 2" 7' - 0 " 1' - 7 3 / 4 " R4" 8" 2"1'-0" 9' - 0 " C O O R D I N A T E H E I G H T A N D P L A C E M E N T BLACK IRON FLANGE SEALED SEE SIGN PACKAGE 3/4" BLACK PIPE SEALED WALL OR FACE OF SF SYSTEM FIELD VERIFY EXIST CONDITIONS 4) 1x WOOD SHELVES CUSTOM BIRCH STAIN SEALED SECURE TO SLAB W/ BLACK CONCRETE ANCHORS AT WALL MOUNTED OPTION, PROVIDE 2x SOLID WOOD BLOCKING SECURED TO FRAMING CEILING MOUNT ELEVATION VIEW NOTES: ·WOOD BLOCKING TO BE FRT LUMBER IN TYPE II CONSTRUCTION. ·SHELF BY OWNERS MILLWORK VENDER, BLOCKING AND INSTALL BY GC WALL MOUNT SELECTION OPTION CEILING MOUNT SELECTION OPTION PLAN VIEW WALL MOUNTED OPTION SECTION AT WALL COUNTER 1 1 / 4 " 1" SF-1SF-1 1 1 / 4 " 1" SF-1 SUPPORT POSTS WITH TOP AND BOTTOM PLATES, EQUAL SPACED - FINISH POWDER COAT (FLAT BLACK), POSTS ARE PROVIDED BY K.E.C. CORE DRILL TO SLAB BY G.C. 3' - 6 " G A-10 TABLE / STOOL POST 3/16" THICK, 4 1/2" DIA. STEEL COVER PLATE, WELDED TO COLUMN FOR FLOOR FINISHES SEE SHEET A-3 ANCHORING CEMENT CONCRETE SLAB 1' - 0 " 4' - 0 " 1' - 0 " 6' - 0 " 4" 3' - 4 " 4" 4' - 0 " 8 1/2"8 1/2" 1'-5" 1" 2' - 6 1 5 / 1 6 " SF-1 SF-1 F A-10 E A-10 SECTION AT WALL COUNTER (ADA ACCESSIBLE) 1 1 / 4 " 1" SEE PLAN SF-1SF-1 1 1 / 4 " 1" SF-1 SUPPORT POSTS WITH TOP AND BOTTOM PLATES, EQUAL SPACED - FINISH POWDER COAT (FLAT BLACK), POSTS ARE PROVIDED BY K.E.C. CORE DRILL TO SLAB BY G.C. 2' - 6 " D2 G A-10 JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H NOTE: INFORMATION THIS SHEET PROVIDED FOR REFERENCE ONLY 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com A-10 CABINET DETAIL DRINK STATION COUNTER 3/4" = 1'-0"A DRIVER'S BOX DETAIL 1 1/2" = 1'-0"B 3/4" = 1'-0"C WINDOW/WALL COUNTER 3/4" = 1'-0"F 1/4" = 1'-0"G WALL/WINDOW COUNTER SECTION 3/4" = 1'-0"D WALL/WINDOW COUNTER SECTION 3/4" = 1'-0"E 5" 3" 5'-2" 5"4'-4"5" 1' - 2 " 4' - 7 " 10 " 5' - 5 " TOP OF CURB 3/4" CONDUIT FOR 120 VAC POWER PREFABRICATED ANCHOR BOLT CAGE PROVIDED BY G.C. 6" STUB-UP FOR CONDUITS 1'-6"1'-6" 3' - 0 " CONCRETE FOOTING BY G.C. VERIFY FROST DEPTH PER LOCAL CODE/ADJUST DRIVE THRU MENU BOARD 1/2" = 1'-0"D 1'-3" 5'-0" MICROPHONE: 22 GA RED & BLACK 2 CONDUCTOR- AUDIO CABLE-OUTDOOR WIRE GROUND WIRE (BLUE OR BLACK) SPEAKER: 22 GA WIRE, COLOR IS GREEN & WHITE 3/4" COMMUNICATION CONDUIT TO RUN TO COMMUNICATION PANEL NOTE: SOLDER & INSULATE BOTH MAGNETIC LOOP CONNECTION FOR DUPLEX OPERATION IMPORTANT: AUDIO CABLE MUST BE SHIELDED, TWISTED PAIR AND THE CABLE FOR THE MICROPHONE MUST IN A SEPARATE CABLE. IF THE MICROPHONE WIRING IS IN A CABLE WITH OTHER PAIRS (BEING USED ELECTRICALLY IN THE SYSTEM), COMMUNICATION PROBLEMS WILL OCCUR. MAGNETIC LOOP (COORDINATE REQ'TS WITH J.J.'S CONSTRUCTION MANAGER) DETECTION/SPEAKER ISOMETERIC N.T.S.C CUT CONDUIT 2" ABOVE CONCRETE FOR MIC/SPEAKER G.C. TO COORDINATE INSTALLATION OF EQUIPMENT PER THE MAIN STREET MENU SYSTEMS REQUIREMENTS (A PRODUCT OF THE HOWARD COMPANY, INC.) 10 1/2" LOOP SUPPORT CONC. BASE-1'-6" X 1'-6" X 1'-6" FLUSH W/ TOP OF CONCRETE 3/4" COMMUNICATION CONDUIT FROM COMMUNICATION PANEL 1'-6" 1' - 6 " MAGNETIC LOOP CONCRETE SPEAKER STAND 3' - 4 " VERIFY FROST DEPTH PER LOCAL CODE/ADJUST SPEAKER POST DETAIL 1/2" = 1'-0"B SMOOTH SLOPED MORTAR CAP PAINTED 6" ø STANDARD STL.PIPE FILLED WITH CONCRETE AND PAINTED PT-9 (2 COATS MIN.) EXISTING PAVEMENT 18" ø CONCRETE FOOTING (2) NO. 6 BARS 12" LONG EACH WAY, WELD TO PIPE 1 1 / 2 " 9"9" 3" M I N . 3' - 0 " M I N I M U M 4' - 0 " PIPE BOLLARD DETAIL 3/4" = 1'-0"E PIPE BOLLARD - SEE: E/ A-11 CUT CONCRETE AS REQUIRED - PATCH W/ NEW TO MATCH SPEAKER POST SEE B/A-11 3/4" COMMUNICATION CONDUIT TO COMMUNICATION PANEL 3/4" CONDUIT FOR POWER TO ELECTRICAL PANEL MENU BOARD - SEE:D/A-11 PIPE BOLLARD - SEE: F/ A-11 (TO BUILDING CORNER) MAGNETIC LOOP BELOW CONCRETE DRIVE - CUT/REPLACE ASPHALT AS REQUIRED (REF TO MEP DRAWINGS) (T O B U I L D I N G ) 69 ' - 1 " 30'-2" 1'-8"5"4'-0 1/2" 1' - 2 " 3' - 0 " 1' - 8 " MENU BOARD - SEE:D/A-11 3/4" CONDUIT FOR POWER TO ELECTRICAL PANEL 2'-10" 2' - 6 " 2' - 6 " 1' - 1 0 " JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON A-11 DRIVE THRU DETAILS DRIVE THRU EQUIPMENT PLAN 1/2" = 1'-0"A JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON 5 FE FE FE A-11 A EXISTING PARKING TO REMAIN PROVIDE 10'X20' CONCRETE PAD AT DT WINDOW AND ORDER POINT WITH LOOP DETECTOR 10 7 8 " 4 ' - 9 1 2 " EXISTING DRIVE THRU WINDOW MAGNETIC LOOP TO TIE INTO COMMUNICATION PANEL AT DRIVE THRU WINDOW - REF. COM-1 SHEET FOR TIMER DETAIL NEW PIPE BOLLARDS NOTES: 1.DRIVE THRU LANES, CURBS, PARKING SPACES, SIDEWALKS, AND RAMPS ARE ALL EXISTING UNLESS OTHERWISED NOTED. G.C. TO VERIFY THAT DRIVE THRU LANES, CURBS, PARKING SPACES, SIDEWALKS, RAMPS, AND STRIPPING TO CONFORMS TO ALL STATE AND LOCAL CODES. 2.DAMAGE CAUSED BY NEW CONSTRUCTION SHALL BE PATCHED AND REPAIRED BACK TO NEW CONDITION 3.DRIVE THRU LAYOUT AND APPROVALS TO BE COMPLETED BY LANDLORD UNDER SEPARATE CONTRACT 4.G.C. TO COORDINATE MENU BOARD AND SPEAKER POST LOCATION WITH DRIVE THRU LANE. ADD CLEARANCE BAR N E P L A Z A D R I V E S E EXISTING BUILDING E X I S T I N G D R I V E T O R E M A I N E X I S T I N G D R I V E T O R E M A I N EXISTING DRIVE TO REMAIN EXISTING DRIVE TO REMAIN EXISTING SIDEWALK TO REMAIN JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON A-12 DRIVE THRU PLAN DRIVE THRU PLAN 3/32" = 1'-0"A G E N E R A L N O T E S 1.G.C. TO COORDINATE INSTALLATION OF EQUIPMENT PER THE MAIN STREET MENU SYSTEMS REQUIREMENTS (A PRODUCT OF THE HOWARD COMPANY, INC.) 2.RECESS OR CONCEAL ALL EXPOSED OR SURFACE MOUNTED CONDUIT TO THE BEST OF ABILITY. 3.REPLACE ANY DAMAGED GUTTERS AND DOWNSPOTS WITH NEW; PAINT ALL SW TRICORN BLACK, USE REAL RED AT PRIMARY GABLE PER CORPORATE PROVIDED RENDERING. 4.BUILD NEW DUMPSTER ENCLOSURE CONSISTING OF: CORRUGATED METAL DECKING WITH STEEL POSTS ON ALL CORNERS AND SEAMS. STEEL FRAMED METAL GRATE. PAINT TO MATCH THE BUILDING. JI M M Y J O H N ' S 25-892-812 03-25-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E . , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 25006961 REGISTERED ARCHITECT JENNIFER NIX STATE OF WASHINGTON NORTH FE FE FE FE FE FE S1 50 S1 300 S1 300 S1 250 S1 250 S1 250 S1 300 S1 275 S1 300 6" 10" 10" 14X12 10X12 10" 10" 14 X 1 4 10 X 1 4 18 X 1 8 S1 275 S1 275 S1 250 S1 250 S1 275 S1 150 14 X 1 4 12 " 1 2 X 1 0 10" 10"DN 10" 10" 10" 10" 12 R1 835 EF 13 T (RTU-2) 1 T (RTU-1) 1 RTU 1-EX 5 11 RTU 2 5 4 7 10 " 10 " 10" 14X14 DN R1 840 12 18 X 1 8 18X18 10"DN 6 8 9 14 13 WH EX WH EX10 10 12 R1 710 R1 715 12 14X14 14X14 DN 18X18 7 18X18 DN FROM RTU (TYP) (TYP) (TYP) 3 WAY DIFFUSER. SHADED PORTION TO BE BLOCKED OFF. M-1 PLAN MECHANICAL MECHANICAL PLAN 1/4" = 1'-0"A RESTROOM EXHAUST N.T.S.1 ~~ BRANCH DUCT MAIN DUCT ROUND BRANCH DUCT DUCT UNDER BEAM OR CROSSOVER RECTANGULAR MAIN / ROUND BRANCH DUCT RECTANGULAR BRANCH DUCT "B" 45°FL O W FL O W 45° (TYPICAL) IN FIELD) (VERIFY ROUTING EXHAUST(RESTROOM) RUBBER-IN-SHEAR VIBRATION ISOLATORS EXHAUST FAN DISCHARGE CAP W/ BIRD SCREEN METAL ROOF CURB EXHAUST DUCT BY MECH. CONTR. FLEX. CONN. ROOFLINE TYPICAL CEILING DIFUSER N.T.S.3 2'-0" 6" 2" EXISTING GIRDER OR BEAM RUN EXPOSE DUCT TIGHT TO DECK/UNDER GIRDER DUCT CONNECTION DETAILS N.T.S.2 DAMPER R-1 S-1 FLEXIBLE DUCT SYMBOL DESCRIPTION RETURN AIR GRILLE 24x24 SUPPLY AIR DIFFUSER DUCT SMOKE DETECTOR EXHAUST AIR GRILLE TEMPERATURE SENSORT 1.HVAC CONTRACTOR TO COORDINATE INSTALLATION WITH ALL TRADES. 2.CONTRACTOR TO COORDINATE WITH ARCHITECT FOR EXACT LOCATION OF RTU AND ALL REQUIREMENTS. 3.ALL THREAD FOR DUCT WORK SUPPORTS ARE TO BE FASTENED TO SOLID BLOCKING ABOVE DRYWALL. 4.ALL EXPOSED DINING DUCTWORK TO BE SPIRAL DUCT. SD G E N E R A L N O T E S H V A C L E G E N D MANUAL AIR VOLUME DAMPER NEAR MAIN DUCT, TYPICAL DAMPER ARM CONTINUOUS ROD ON ALL DAMPERS OVER 12" DIA. MOUNT BOTTOM OF DUCT AT 10'-14' AFFATTACH RIGID DUCT TO FLEX DUCT WITH STRAP, TYP. BRANCH DUCT FLEXIBLE DUCT, MAX LENGTH 5'-0" TO BE USED IN VERTICAL DROP ONLY 90° BEND MUST BE RIGID ROUND DUCT. SECURE WITH (4) #10 SCREWSDIFFUSER T-RUNNER, TYPICAL ACOUSTIC CEILING TILE/ GRIDFIELD FABRICATED 6" SQUARE TO ROUND ADAPTOR. MANUAL VOLUME DAMPER ON FITTING, TYPICAL SADDLE TAP OR SPIN-IN FITTING ROUND BRANCH MANUAL VOLUME DAMPER RECTANGULAR MAIN DUCT MAIN DUCT BRANCH DUCT 1/4 OF "B" R O U N D D U C T S P E C I F I C A T I ON JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com ALL EXPOSED DUCTWORK IN DINING AREA MUST BE ROUND SPIRAL DUCTWORK. SQUARE OR RECTANGULAR DUCTWORK IS NOT PERMITTED. ROUND SPIRAL DUCTWORK MUST BE MIN. 24 GAUGE, SINGLE WALL, GALVANIZED STEEL WITH SPIRAL LOCK SEAM OR SOLID WELDED CONSTRUCTION. ELBOWS SHALL BE STANDING SEAM, GORED ELBOWS. SUPPLY GRILLES SHALL BE MOUNTED ON GRILLE COLLARS TO BE ATTACHED TO DUCTWORK WITH POP RIVETS WITH A FINISHING FILLET OF ELASTOMER SEAL AT THE JUNCTION OF THE COLLAR TO THE DUCT. DUCT TO DUCT JOINTS SHALL BE MADE WITH THE SPIRAL SEAM ROTATED SO THAT THE STANDING SEAM FORMS A CONTINUOUS HELICAL PATTERN ACROSS THE JOINT. ALL DUCTWORK AND FITTINGS SHALL BE MANUFACTURED IN ACCORDANCE WITH LATEST SMACNA HVAC DUCT CONSTRUCTION STANDARDS. ALL EXPOSED ROUND DUCTWORK AND FITTINGS IN THE DINING AREA SHALL BE CLEANED OF ALL OILS AND COATINGS PRIOR TO INSTALLATION. PROVIDE WITH A MILL PHOSPHITIZED FINISHING ("PAINT GRIP" OR SIMILAR ETCH TREATMENT) TO ALLOW THE DUCTWORK TO BE PAINTED. REFER TO ARCHITECTURAL DRAWINGS FOR COLOR. NORTH NOTE: CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECTED MOUNTED. REFERENCE SHEET MEP-3 FOR ALTERNATE COMPRESSOR INSTALLATION. FIELD VERIFY ALL EXISTING CONDITIONS AND UTILITIES LOCATIONS PRIOR TO BID. CONTRACTOR TO COORDINATE NECESSARY REQUIREMENTS WITH ALL OTHER TRADES. NOTIFY ENGINEER OF RECORD OF ANY DISCREPANCIES BETWEEN SITE CONDITIONS AND PLANS. * KEYED NOTES PROGRAMMABLE THERMOSTAT FOR RTU WITH CLEAR LOCK BOX COVER AT +48" A.F.F. - COORDINATE RECESSED "J" BOX WITH ALL FINISH WALL MATERIALS/DEVICES. RELOCATE THERMOSTAT SERVING EXISTING RTU TO SHOWN LOCATION. FULL SIZE RETURN DUCT DOWN TO RA GRILL. RELOCATE EXISTING EXHAUST FAN IF CONDITION GOOD. ROUTE 6"Ø RESTROOM EXHAUST TO ATMOSPHERE A MINIMUM OF 10'-0" FROM ANY FRESH AIR INTAKE- SEE 1/M-1. PROVIDE ROOF CAP. NEW DUCTWORK SHALL BE INSULATED WITH MINIMUM INSTALLED VALUE R-6 INSULATION. ALTERNATE BID: SEE SHEET M2 FOR NEW EXHAUST FAN MODEL IF REPLACEMENT NEEDED. NEW PACKAGE ROOFTOP UNIT. COORDINATE EXACT LOCATION AND STRUCTURAL REQUIREMENTS WITH STRUCTURAL ENGINEER. PROVIDE ADDITIONAL BRACING AS REQUIRED. UNIT SHALL BE INSTALLED PER MANUFACTURE'S INSTRUCTIONS AND RECOMMENDED CLEARANCES MAINTAINED. CONDENSATE FROM RTU TO BE ROUTED TO CONCRETE SPLASH BLOCK ON ROOF, OR PER AHJ STANDARD. EXISTING CONDENSATE SERVING EXISTING RTU TO REMAIN AS IS. MECHANICAL CONTRACTOR TO COORDINATE INSTALLATION OF DUCTWORK AND DIFFUSERS WITH LIGHT FIXTURES. TYPICAL. COORDINATE ANY NEW ROOF PENETRATIONS WITH LANDLORD ROOFING CONTRACTOR AND STRUCTURAL ENGINEER / TRUSS MANUFACTURER. PROVIDE EXTERNAL MINERAL FIBER INSULATION TO ACHIEVE A MINIMUM R VALUE AS REQUIRED BY CODE AND TO PREVENT CONDENSATION ABOVE CEILING ONLY. TYPICAL. SECTORIZED DAMPER FOR DIFFUSER- SEE 2/M-1 AND 3/M-1. TAP BOTTOM OF DUCT FOR CONNECTION. PROVIDE PLASTER FRAME WHERE REQUIRED. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPE. TYPICAL. EXISTING WATER HEATER VENT(S) TO REMAIN. ANY REQUIRED MODIFICATIONS OR REPLACEMENT TO BE BY PLUMBER. PLUMBER SHALL OFFSET AS REQUIRED TO MAINTAIN 10FT FROM ANY OUTDOOR AIR INTAKE. EXISTING RTU TO REMAIN. REPLACE ALL FILTERS AND BELTS. VERIFY REFRIGERANT CHARGE AND ADD AS REQUIRED. CONTRACTOR SHALL FIELD VERIFY OPERATION AND PROVIDE WRITTEN ESTIMATE TO OWNER IF ADDITIONAL REPAIRS ARE REQUIRED. R.A. GRILLE FLUSH IN CEILING OR WALL. - PAINT TO MATCH PER ARCHITECTURAL DRAWINGS. DUCT TO BE RUN AS HIGH AS POSSIBLE AND AS TIGHT TO BOTTOM CHORD OF JOISTS AS POSSIBLE WHEN REQUIRED. TYPICAL. CONTRACTOR TO PROVIDE CYL-TEK MK90 CO2 DETECTOR STAND-ALONE SYSTEM. MOUNT WITHIN 12" OF FINISH FLOOR. NOTE: DUCTWORK DESIGNED FOR COOLING SUPPLY TEMPERATURE OF 58°F. DUCTWORK DESIGNED FOR HEATING SUPPLY TEMPERATURE OF 100°F. NOTE: CONTRACTOR(S) SHALL PROVIDE OWNER, ARCHITECT AND ENGINEER WITH ALL RECORD DOCUMENTS WITHIN 90 DAYS OF CERTIFICATE OF OCCUPANCY. FOR LIST OF DOCUMENTS REQUIRED REFER TO WSEC C103.6. NOTE: DUCTWORK DESIGNED FOR COOLING SUPPLY TEMPERATURE OF 58 FAHRENHEIT. DUCTWORK DESIGNED FOR HEATING SUPPLY TEMPERATURE OF 100 FAHRENHEIT. M-2 AND SCHEDULES MECHANICAL NOTES 1.AIR BALANCING A.CONTRACTOR SHALL PROCURE THE SERVICES OF AN INDEPENDENT NEBB OR AABC CERTIFIED AIR BALANCE AND TESTING AGENCY TO BALANCE, ADJUST & TEST EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE/TEST AGENCIES REPORT TO P.S.S. PROJECT MANAGER AND LANDLORD OPERATIONS DIRECTOR FOR REVIEW. MIN. OUTDOOR C.F.M. AND INDOOR FAN C.F.M. SHALL BE PROVIDED AS SHOWN ON RTU SCHEDULE. 2.DUCTWORK A.INSTALL ALL DUCTWORK IN COMPLETE CONFORMANCE WITH RECOMMENDED CONSTRUCTION STANDARDS FOR RECTANGULAR AND ROUND SHEET METAL AND FLEXIBLE DUCTS IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS AND ALL OTHER AUTHORITIES HAVING JURISDICTION. FLEXIBLE DUCT SHALL NOT EXCEED 5'-0" IN LENGTH. MINIMUM SHEETMETAL THICKNESS SHALL BE 26 GA. B.ALL DUCT JOINTS LONGITUDINAL AND TRANSVERSE ARE TO BE SEALED USING 181A OR 181B LISTED TAPES AND MASTICS. MECHANICAL FASTENERS MUST BE USED TO FASTEN DUCTS. C.STRAP HANGERS SHALL NOT BE LESS THAN 1" BY 1/8" THICK ON SIX (6) FOOT CENTERS AND ATTACHED TO SIDE OF DUCT WITH SHEET METAL SCREWS. INSULATED FLEXIBLE DUCT MAY BE USED FOR LOW PRESSURE RUNOUTS TO INDIVIDUAL DIFFUSERS IN LENGTHS NOT TO EXCEED FIVE (5) FEET FOR EACH DIFFUSER. SEAL ALL SHEETMETAL SCREW PENETRATIONS. D.ROUND DUCT (IF REQUIRED) SHALL BE EXTERNALLY INSULATED WITH 1-1/2" THICK FLEXIBLE BLANKET WITH AN INTEGRAL VAPOR BARRIER. E.ALL RECTANGULAR SUPPLY DUCTWORK SHALL BE INTERNALLY INSULATED WITH A MINIMUM THICKNESS THAT CONFORMS TO THE STANDARD CODE AND SHALL IN NO CASE BE LESS THAN 2" AND SHALL HAVE A CONTINUOUS VAPOR BARRIER JACKET W/ALL JOINTS TAPED AND SEALED. F.FRESH AIR DUCT SHALL HAVE 2" INTERNAL DUCT LINER FROM POINT OF OUTSIDE AIR CONNECTION TO POINT OF CONNECTION AT PLENUM BOX OR MIXING BOX. G.ALL EXPOSED SPIRAL DUCT (IF REQUIRED) SHALL HAVE SPIRACOUSTIC INTERNAL DUCT LINER, OR TOUGHGARD ULTRA ROUND BY CERTAINTEED. H.PROVIDE FLEXIBLE CONNECTION BETWEEN ALL FAN POWERED EQUIPMENT AND CONNECTING DUCTWORK. I.ALL INSULATION, JOINING MATERIALS, SEALER, ETC.. SHALL HAVE A U.L. FLAME SPREAD CLASSIFICATION OF NO MORE THAN 25 AND A SMOKE DEVELOPMENT RATING NOT MORE THAN 50. J.ALL DUCTWORK SHALL BE CONSTRUCTED AND SEALED IN COMPLIANCE WITH WSEC C403.10.1.1 AND C403.10.2. ALL OUTDOOR AIR DUCTWORK SHALL BE SEALED IN ACCORDANCE WITH WSEC C402.5 WITH VAPOR RETARDER AND MEET AIR LEAKAGE REQUIREMENTS. 3.AIR DEVICES A.SUPPLY DIFFUSERS: (TITUS AS STANDARD) SHALL BE FURNISHED WITH BAKED WHITE ENAMEL FINISH, AND SHALL BE SELECTED FOR NECK VELOCITIES NOT EXCEEDING 800 FPM AND NOISE LEVEL OF NC-35 OR LESS. B.SUPPLY DIFFUSERS SHALL BE ROUND NECK, STEEL, MODEL TMSAA, SIZED USING CRITERIA INDICATED ABOVE FOR LAY-IN CEILING GRID TYPE CONSTRUCTION OR DRYWALL CEILING AS INDICATED ON DWG. DIFFUSERS SHALL BE COMPLETE WITH ADJUSTABLE AIR PATTERNS AND VOLUME CONTROL DAMPERS. C.RETURNS SHALL BE SQUARE NECK ALUM. MODEL 50F AND/OR AS NOTED ON PLANS AND AIR DEVICE SCHEDULE. FACE VELOCITY OF RETURN REGISTERS SHALL NOT EXCEED 500 FPM. VOLUME CONTROL DAMPER NOT REQUIRED FOR RETURN INSTALLATION EXCEPT WHERE NOTED. D.COORDINATE LOCATION OF AIR DEVICES WITH LIGHTS, SPRINKLERS, SPEAKER, SMOKE DETECTORS, ETC. 4.EQUIPMENT A.REFER TO MECHANICAL PLANS FOR SPECIFICATIONS OF HVAC EQUIPMENT. B.ALL NEW EQUIPMENT SHALL BE EQUIVALENT TO THE SPECIFIED ITEM. ANY ACCOMMODATIONS FOR ALTERNATE MANUFACTURERS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. C.NEW PLATFORM EQUIPMENT SHALL HAVE VIBRATION ISOLATION MOST SUITABLE FOR THE APPLICATION. D.ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURERS INSTRUCTIONS. E.COORDINATE UNIT LOCATION WITH LANDLORD AND SITE CONDITIONS. F.GAS PIPING SHALL BE SCHEDULE 40 (ASTM-A120) BLACK STEEL WITH 300 lb. MALLEABLE IRON BANDED SCREWED OR WELD PATTERN FITTINGS AS APPLICABLE. G.ALL PIPING AND FITTINGS LOCATED OUTDOORS AND ABOVE GRADE SHALL BE CLEANED FREE OF RUST AND PAINTED. ALL FITTINGS TO BE MADE WITH PIPE JOINT COMPOUND. TEFLON TAPE NOT ALLOWED. H.ROOF CURBS BY CONTRACTOR. 5.CONTROLS A.PROVIDE CONTROLS AS SPECIFIED. SPECIAL CONTROL METHODS WILL BE ADDRESSED ON AN INDIVIDUAL BASIS. B.THE CONTRACTOR SHALL PROVIDE ALL 24V WIRING INCLUDING CONNECTIONS, CHECK, TEST AND START-UP. C.CONTRACTOR SHALL SUPPLY AND PROGRAM CONTROLS TO SATISFY THE ENERGY CODE REQUIRED BY THE LOACAL ENERGY CODE. A 5°F DEADBAND SHALL BE PROGRAMMED WITH CAPABILITY OF 55°F HEATING AND 85° COOLING SETBACK TEMPERATURE. CONTROLS SHALL ALSO HAVE AN ACCESSIBLE 2 HOUR OCCUPANT OVERRIDE. D.SCOPE OF WORK A. FURNISH AND INSTALL A COMPLETE BAS FOR ALL HEATING, VENTILATING, AND AIR CONDITIONING SYSTEMS AND OTHER FACILITY SYSTEMS AS HEREIN DESCRIBED. THE BAS SHALL UTILIZE DIRECT DIGITAL CONTROL (DDC) AND ELECTRONIC ACTUATION. DDC SYSTEM SHALL PERFORM THE SEQUENCES OF OPERATION AND BE PROVIDED WITH THE CONTROL POINTS AS LISTED IN THIS SECTION. THE BASE SYSTEM DESIGN OF THE BAS SHALL INCLUDE THE FOLLOWING: 1. HEATING/COOLING RTU WITH DEMAND CONTROLLED VENTILATION. E.SYSTEM DESIGN A. IT IS THE DESIGN INTENT TO HAVE ONE DIGITAL CONTROLLER FOR EACH SPECIFIED CONTROL SYSTEM. SPLITTING THE CONTROL POINTS ASSOCIATED WITH A PARTICULAR SYSTEM BETWEEN DIGITAL CONTROLLERS SHALL NOT BE ALLOWED, EXCEPT FOR COMMON DATA POINTS SUCH AS OUTDOOR AIR TEMPERATURE. B. ALL DDC CONTROLLERS SHALL BE NETWORKED TOGETHER. ALL DDC SYSTEM POINTS SHALL BE ACCESSIBLE THROUGH THE BAS USER INTERFACE. C. ALL ROOFTOP UNITS WITH DDC CONTROLLERS TO BE NETWORKED TOGETHER ON A COMMON COMMUNICATION BUS AND SHARE A GLOBAL SCHEDULE. D. DDC CONTROLLER SHALL BE CAPABLE OF RECEIVING UTILITY SIGNAL TO ADJUST TEMPERATURE SET POINT UP TO 3 DEGREES OVER 3HRS DURING TIMES OF PEAK ENERGY USAGE. F.USER INTERFACE A. PROVIDE A MAIN LCD USER INTERFACE NETWORKED AND CAPABLE OF VIEWING ALL DDC CONTROLLERS. INTERFACE TO HAVE CAPABILITIES OF CHANGING SETPOINTS, VIEWING CONTROLLER ALARMS, AND SCHEDULING OCCUPANCY. G.RTU WITH DEMAND CONTROLLED VENTILATION A. SYSTEM DESCRIPTION 1. CONSTANT VOLUME ROOFTOP WITH DDC CONTROLLER 2. WALL-MOUNTED TEMPERATURE SENSOR IN THE SPACE 3. COMBINATION CO2 AND TEMPERATURE SENSOR MOUNTED NEAR THE RTU RETURN AND WIRED TO THE RTU CONTROLLER IAQ INPUT FOR DEMAND CONTROLLED VENTILATION OPERATION. B. SEQUENCE OF OPERATION 1. THE RTU CONTROLLER SHALL INCLUDE AN OCCUPANCY SCHEDULE ADJUSTABLE VIA THE WALL-MOUNTED LCD INTERFACE. 2. DEMAND CONTROLLED VENTILATION A. THE SPACE CO2 LEVEL SHALL BE COMPARED TO THE CO2 SETPOINT IN THE RTU CONTROLLER. IF THE READING IS BELOW THE CO2 SETPOINT, THE RTU SHALL MAINTAIN THE BASE VENTILATION RATE. IF THE READING IS AT/ABOVE SETPOINT, THE RTU CONTROLLER SHALL MODULATE THE OUTSIDE AIR DAMPER OPEN TO REDUCE THE CO2 READING IN THE SPACE. B. THE RTU SHALL MODULATE THE PREHEAT CONTROL TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. C. THE RTU'S ECONOMISER CONTROL DETERMINES IF IT IS BENEFICIAL TO USE OUTSIDE AIR FOR FREE COOLING. THE ECONOMIZER SHALL OVERRIDE THE DEMAND CONTROLLED VENTILATION ALGORITHM TO MODULATE THE DAMPERS TO THEIR MAXIMUM POSITION. 1. ECONOMIZER SHALL COMPLY WITH 2021 WSEC C403.5.1 INTEGRATED ECONOMIZER CONTROL. 2. ECONOMIZER SHALL BE UTILIZED AS STAGE-1 OF COOLING WHEN AMBIENT TEMPERATURES WILL PROVIDE COOLING TO SPACE. 3. ECONOMIZER SHALL INCLUDE HIGH-LIMIT SHUT OFF TO REDUCE OUTDOOR AIR WHEN AMBIENT TEMPERATURES NO LONGER REDUCE COOLING ENERGY USAGE AS DESIGNATED BY 2021 WSEC TABLE 403.5.3.3. 1.THE GENERAL AND SPECIAL CONDITIONS OF THE ARCHITECTURAL SPECIFICATIONS SHALL BE INCLUDED AS PART OF THESE DOCUMENTS. 2.ALL MATERIALS SHALL BE NEW, UNUSED, AND THE BEST OF THEIR RESPECTIVE KINDS AND FREE FROM DEFECTS. 3.THE CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE AIR DISTRIBUTION SYSTEM WITHIN THE TENANT SPACE TO INCLUDE, BUT NOT LIMITED TO ALL DUCTWORK, HANGERS, INSULATION, VAPOR BARRIER, SUPPLY DIFFUSERS, RETURN GRILLES, FLEXIBLE CONNECTIONS, AND CONTROL INSTALLATION AS REQUIRED FOR A COMPLETE AND WORKING SYSTEM. THE CONTRACTOR SHALL PAY ALL FEES, GIVE ALL NOTICES, FILE ALL NECESSARY DRAWINGS AND OBTAIN ALL PERMITS AND CERTIFICATES OF APPROVAL REQUIRED IN CONNECTION WITH ALL WORK UNDER THIS CONTRACT. ALL WORK SHALL BE FURNISHED AND INSTALLED IN FULL ACCORDANCE WITH ALL LAWS, ORDINANCES, RULES AND REGULATIONS. 4.DRAWINGS ARE DIAGRAMMATIC ONLY, INTENDING TO SHOW GENERAL RUNS AND LOCATIONS OF THE WORK AND ARE NOT INTENDED TO BE RIGID IN SPECIFIC DETAIL. 5.THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE SITE FOR HIS WORK BEFORE HAVING SUBMITTED HIS PROPOSAL. NO ADDITIONAL COMPENSATION WILL BE ALLOWED FOR CONDITIONS FOUND DURING THE COURSE OF THE CONTRACT. 6.THE CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AT THE SITE AND BE RESPONSIBLE FOR THE CORRECTNESS OF THE SAME. 7.THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF HIS WORK WITH LIGHTING PLANS, REFLECTED CEILING PLANS, LANDLORD'S SPRINKLER PLANS AND ALL OTHER TRADES. 8.THE INSTALLATION OF ALL EQUIPMENT AND MATERIALS REQUIRING ACCESS SHALL BE MADE IN SUCH MANNER AS TO MAKE THE EQUIPMENT AND MATERIALS READILY ACCESSIBLE FOR OPERATION, MAINTENANCE AND REPAIRS. 9.STORAGE OF CONSTRUCTION EQUIPMENT AND MATERIALS SHALL BE ONLY IN SPACES AS DESIGNATED BY THE ARCHITECT/OWNER. 10.CONSTRUCTION DEBRIS AND RUBBISH GENERATED BY THE CONTRACTOR SHALL BE REMOVED FROM PREMISES AS OFTEN AS NECESSARY OR AS DIRECTED TO MAINTAIN A CLEAN AND WORKABLE AREA. 11.ALL WORK AND EQUIPMENT SHALL BE FULLY GUARANTEED FOR ONE (1) YEAR FROM THE DATE OF FINAL PAYMENT AND ACCEPTANCE. 12.ALL WORK, INCLUDING INSIDE OF SUPPLY AIR DUCTS, AND EQUIPMENT WITHIN THE CONTRACT AREA FURNISHED AND INSTALLED UNDER THIS CONTRACT SHALL BE CLEANED TO THE SATISFACTION OF THE OWNER BEFORE TURNING SAME OVER TO THE OWNER. 13.CONNECT NEW WORK TO EXISTING IN A NEAT AND APPROVED MANNER. 14.INTERRUPTION OF HEATING, POWER AND AUXILIARY SYSTEMS WHERE AND IF REQUIRED SHALL BE COORDINATED AND SHALL OCCUR ONLY DURING PREARRANGED ACCEPTABLE TIMES. 15.ALL DESIGN SHALL INCORPORATE CURRENT ASHRAE METHODS. 16.WHEN EXISTING DUCTWORK IS UTILIZED, SIZES SHALL BE AS SHOWN ON DWGS. AS MINIMUM REQUIREMENT. A.DUCT SIZES SHOWN ARE SHEET METAL DIMENSIONS. NOT DUCT LINER. REFER TO MECHANICAL SPECIFICATIONS FOR DUCT INSULATION REQUIREMENTS. B.PROVIDE SINGLE WALL TURNING VANES @ ALL ELBOWS AND TEES PER SMACNA STANDARDS. C.DO NOT PROVIDE AIR EXTRACTORS OR SPLITTER DAMPERS WHICH PROTRUDE INTO RECTANGULAR TRUNK DUCTS. PROVIDE ROUND SPIN-IN FITTINGS FOR ROUND BRANCH DUCTS. D.ROUND BRANCH DUCTS ARE SAME SIZE AS DIFFUSER WHICH THEY SERVE. E.CONTRACTOR SHALL FIELD VERIFY THE EXACT SIZE, LOCATION, AND CONDITION OF ALL EXISTING EQUIPMENT, PIPING, DUCTWORK, ETC. TO BE REUSED, RETAINED OR CONNECTED TO. F.CONTRACTOR SHALL COMPLY WITH ALL LANDLORD'S TENANT CRITERIA. COORDINATE AND SCHEDULE ALL WORK WITH LANDLORD'S FIELD REPRESENTATIVE. G.MAXIMUM FLEXIBLE DUCT LENGTH SHALL NOT EXCEED 5'-0". REFER TO MECHANICAL SPECIFICATIONS ON SHEET M-2. H.CONTRACTOR SHALL PROCURE THE SERVICES OF A APPROVED NEBB OR AABC CERTIFIED AIR BALANCE & TESTING AGENCY TO BALANCE, ADJUST & TEST EQUIPMENT. CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING 3 COPIES OF BALANCE/TEST AGENCIES REPORT TO TENANT PROJECT MANAGER AND/OR LANDLORD'S REPRESENTATIVE FOR REVIEW. I.BALANCING OF AIR DEVICES SHALL BE ACCOMPLISHED BY ADJUSTING BRANCH TAKEOFF DAMPER AT MAIN TRUNK DUCT. DAMPERS IN THE NECKS OF AIR DEVICES SHALL BE USED FOR FINAL TRIM ONLY, AND IN NO CASE FOR GREATER THAN 10% IF THE INDICATED VOLUME FOR THE INDIVIDUAL AIR DEVICE. J.DO NOT ATTACH ANYTHING TO THE UNDERSIDE OF THE ROOF DECK. ALL LOADS AND BRACING MUST BE ADEQUATELY SUPPORTED FROM THE BUILDING ROOF STRUCTURE. K.GAS PIPING SHOWN IS FOR LOW PRESSURE GAS IN THE THE BUILDING. CONTRACTOR SHALL VERIFY GAS PRESSURE PRIOR TO CONSTRUCTION. 2 PSIG MAY BE USED IF APPROVED BY AUTHORITIES. AND AS APPROVED BY JIMMY JOHNS. PROVIDE PRESSURE REDUCING VALVES AT EACH APPLIANCE AND VENT AS RECOMMENDED BY MFG. EXTEND NEW GAS LINE BACK TO EXISTING METER. VERIFY METER SIZE WITH UTILITY COMPANY. CONNECT NEW GAS LINE TO EXISTING MANIFOLD. L.ALL ROOF PENETRATIONS SHALL BE APPROVED BY LANDLORD AND DONE IN ACCORDANCE WITH ROOF MANUFACTURERS RECOMMENDATIONS SO AS NOT TO VOID THE WARRANTY. 1.PROVIDE TESTING AND BALANCING FOR ALL AIR SYSTEMS. SUBMIT REPORTS TO ARCHITECT. 2.SUBMIT SHOP DRAWINGS TO ARCHITECT FOR APPROVAL OF MAJOR MECHANICAL EQUIPMENT PRIOR TO ORDERING. 3.SEE ALL OTHER DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL WORK AND CLARIFICATIONS OR WORK TO BE PERFORMED. 4.CONDENSATE FROM ROOFTOP EQUIPMENT SHALL DISCHARGE ONTO ROOF VERIFY WITH CITY CODE OFFICIALS. IF OBJECTIONABLE, EXTEND CONDENSATE PIPE TO APPROVED FLOOR RECEPTOR, OR EXTEND TO APPROVED EXTERIOR LOCATION. SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS OF DIFFUSERS, REGISTERS, GRILLES LOCATED IN THE CEILING GRID. 5.SEE ARCHITECTURAL ROOF PLAN AND DETAILS FOR LOCATION OF NEW ROOFTOP EQUIPMENT. 6.INSULATE LAST 5 FEET OF DUCT FROM TOILET ROOM EXHAUST DUCT WITH 1" THICK FIBERGLASS DUCT WRAP. PROVIDE VAPOR BARRIER. 7.DUCTWORK LAYOUT SHOWN IS RECOMMENDED. ADJUST TO COMPLY WITH CITY CODE REQUIREMENTS AND AS BUILT CONDITIONS. G E N E R A L N O T E S H V A C N O T E S G E N E R A L M E C H A N I C A L C O N D I T I O N SM E C H A N I C A L S P E C I F I C A T I O N S JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com DIFFUSER & GRILL SCHEDULE EXHAUST FAN SCHEDULE (EXISTING-RELOCATED) OUTSIDE AIR CALCULATIONS 2021 WASHINGTON STATE MECHANICAL CODE AIR BALANCE SCHEDULE ROOF TOP UNIT SCHEDULE (NATURAL GAS) EXHAUST FAN SCHEDULE - ALTERNATE BID ROOFTOP UNIT SCHEDULE (HEAT PUMP) HOURS OF OPERATION 11AM TO 9PM OCCUPIED COOLING TEMPERATURE SET POINT: 75 FAHRENHEIT OCCUPIED HEATING TEMPERATURE SET POINT: 70 FAHRENHEIT UNOCCUPIED COOLING TEMPERATURE SET POINT: 80 FAHRENHEIT UNOCCUPIED HEATING TEMPERATURE SET POINT: 65 FAHRENHEIT M-3 CALCULATIONS HEAT LOAD JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com FE FE FE FE FE FE 8A FD 2RD 7 8AFD 2SQ7 19 FS 1 FS 1 CO EX CO EX 19 EX 20 EX 21D EX 21 EX 73 FD 1SQ 11 73 FD 1SQ 11 FD 1SQ WC 1 LAV 1 FD 1RD PVC PVC PVC PV C FS 1 GT 1 4 3 FCO - WCO -8 PV C 3"SS(EX) 3"SS(EX) 3"SS DEMOLISH CLEANOUT AND EXTEND LINE TO SERVE NEW FIXTURES 9 3" S S ( E X ) 3" S S ( E X ) WH EX WH EX 3 " G W 3 " G W FCO -9 3"SS 3" S S 3" S S 3"S S 3"G W 3" S S 3" G W 10 (TYP) 2 16 2 6 6 12 12 FCO -9 1 2 599 FD 1SQ FS 1 13 13 13 13 13 13 DISCHARGE TO NEW FLOOR SINK. DISCHARGE TO NEW FLOOR SINK. 3 " G W 5 JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com G E N E R A L N O T E S 1.ALL FLOOR SINKS, FLOOR DRAINS, FLOOR CLEANOUTS, AND GREASE TRAP SHALL BE INSTALLED SO THAT TOPS ARE FLUSH WITH FINISH FLOOR. 2.CONTRACTOR TO COORDINATE / VERIFY EXACT LOCATIONS FOR ALL FLOOR FIXTURES PRIOR TO SAW-CUTTING. 3.COORDINATE WATER LINES WITH ELECTRICAL CONTRACTOR PIPING SHALL NOT BE ROUTED OVER ELECTRICAL PANEL OR EQUIPMENT. 4.ALL BACKFLOW PREVENTERS SHOULD BE INSTALLED ABOVE THE KITCHEN OR RESTROOM DROP CEILING. IF BFP CANNOT BE INSTALLED ABOVE CEILING, IT MUST BE INSTALLED ABOVE THE MOP SINK, UNDER THE WATER HEATER PLATFORM. BFP SHOULD NOT INTERFERE IN ANY WAY WITH THE OPERATION OF THE KITCHEN. IF AN EXISTING BACKFLOW PREVENTER IS IN A LOCATION OTHER THAN WHAT IS SHOWN ON THESE DRAWINGS, CONTACT THE JIMMY JOHN'S CONSTRUCTION DEPARTMENT IMMEDIATELY FOR DIRECTION ON HOW TO PROCEED 5.ALL PLUMBING AND GAS LINES MUST BE RECESSED WITHIN WALL CAVITIES, UNLESS SPECIFICALLY NOTED OTHERWISE IN THE BLUEPRINTS. NO WATER LINES MAY RUN ALONG WALL. ALL EXISTING MUST BE MOVED 12" OFF OF WALL. IF CANNOT BE MOVED, LINE MUST BE FRAMED AROUND AND FINISHED PER WALL STYLE. ANY APPROVED EXPOSED DRAIN LINES MUST BE COPPER. 6. WALL HUNG TOILETS REQUIRE A MIN. OF A 1 1 2" MAIN WATER SERVICE. 7. GC TO CONFIRM FLOOR DRAIN AND PVC CHASE INSIDE SODA CABINET ARE UNDER COKE MACHINE. 8. IF REQUIRED, GREASE TRAP RELIEF VALVE ACCESS MUST BE SQUARE SHAPED DIAMOND METAL PLATED LID PAINTED - TGIC POWDER COAT - COLOR: ANSI 61 GREY. 9. IF A FLOW CONTROL DEVICE IS REQUIRED AT GREASE TRAP, IT MUST BE INSTALLED UNDERGROUND WITH AN ACCESS PANEL FLUSH WITH FINISHED FLOOR. LID MUST BE A METAL DIAMOND TREAD PLATE PAINTED (TGIC POWDER COAT- ANSI 61 GREY) TO MATCH GREASE TRAP. NOTE: REFER TO PLUMBING RISERS SHEET P-3 FOR PIPE SIZING NOTE: CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECTED MOUNTED. REFERENCE SHEET MEP-3 FOR ALTERNATE COMPRESSOR INSTALLATION. FIELD VERIFY ALL EXISTING CONDITIONS AND UTILITIES LOCATIONS PRIOR TO BID. CONTRACTOR TO COORDINATE NECESSARY REQUIREMENTS WITH ALL OTHER TRADES. NOTIFY ENGINEER OF RECORD OF ANY DISCREPANCIES BETWEEN SITE CONDITIONS AND PLANS. NORTH KEYED NOTES RE-USE EXISTING SEWER AS SHOWN ON PLAN. FIELD VERIFY EXACT LOCATIONS, DIRECTION OF FLOW, INVERT AND SIZE. EXISTING SIZES AND EXISTING FIXTURE LOCATIONS PROVIDED TO ENGINEERS FROM A SITE VISIT. PROVIDE 6" PVC UNDER THE SLAB FOR SODA DISPENSER FROM BAG-N-BOX. VERIFY LOCATION IN ORDER FOR THE SODA LINES TO RUN TO DESIGNATED LOCATION WITHIN SODA CABINET AND BAG-N-BOX. COORDINATE WITH SODA VENDOR AND ALL WASTE LINES. SEE 1/P-1 FOR TERMINATION DETAIL. NEW 50 GPM HYDROMECHANICAL GREASE INTERCEPTOR. NEW GREASE TRAP PROVIDED BY EQUIPMENT VENDOR AND INSTALLED BY CONTRACTOR. COORDINATE CONNECTIONS WITH INSTALLING PIPING. PROVIDE WITH EXTENSION, FIELD VERIFY IF ADDITIONAL EXTENSIONS ARE NECESSARY. ACCESSIBLE FLOW CONTROL DEVICE. PROVIDE ACCESS COVER AND UTILITY BOX. PROVIDE 3/4" HORIZONTAL VENT LINE FROM FLOW CONTROL DEVICE - REVERSE GRADE FROM FIXTURE SERVED. PROVIDE DRAINAGE PATTERN FITTINGS AT HORIZONTAL VENTS AS REQUIRED. ROUTE 3" VENT THROUGH THE ROOF. VERIFY IN FIELD A MIN OF 10'-0" FROM ANY OUTDOOR AIR INTAKE. SEE 4/P1.1 AND SANITARY WASTE ISOMETRIC. WHEN TWO OR MORE VENT PIPES CONVERGE, EVERY DRY VENT SHALL RISE VERTICALLY TO A MINIMUM OF 6 INCHES ABOVE THE FLOOD LEVEL RIM OF THE HIGHEST TRAP OR TRAPPED FIXTURE BEING VENTED. FREEZER/REFRIGERATOR EQUIPMENT IS FURNISHED WITH DEFROST VAPORIZER. NO CONDENSATE LINES FROM EVAPORATORS ARE REQUIRED. DRAIN MUST BE TIGHT TO ONE SIDE OF CABINET TO ALLOW FOR A BAG-N-BOX IF NEEDED. INSTALL WALL CLEAN-OUT 12" A.F.F. CENTERED. F.C.O. - COORDINATE WITH NEW FLOOR FINISHES. CONTRACTOR TO FIELD VERIFY CORRECT CONNECTION (3" OR 4") AND ORDER APPROPRIATE MODEL. DEMOLISH AND CAP ANY EXISTING UNUSED SEWER LINES AND CLEANOUTS. (TYPICAL) INSTALL FLOOR DRAIN AGAINST REAR OF MERCHANDISER, WITH FUNNEL. ROUTE INDIRECT DRAIN FROM #73 TO FLOOR DRAIN. REMOVE EXISTING ABOVE GROUND GREASE TRAP SERVING THE 3 COMP SINK. DISCHARGE 3-COMP SINK INDIRECT INTO NEW FLOOR SINK. SEE DETAIL 3/P1.1 EXISTING FIXTURE TO REMAIN. MODIFY SEWER CONNECTIONS AS NECESSARY TO MEET NEW DESIGN. P-1.1 PLANS PLUMBING 1/4" = 1'-0"A SANITARY WASTE PLAN N.T.S.3 3-COMP SINK DETAIL VENT PITCH AT 1/8"/FT FLOOR DRAIN 4" TRAP SEDIMENT BUCKET FLOOR DRAIN DETAIL N.T.S.2 CONNECT TO TRAP PRIMER ROOFING FLASHING ROOFING 5'-0" MIN. FROM INSIDE WALL TYPICAL VENT THRU ROOF N.T.S.4 FLOOR DRAIN WITH FUNNEL 4" HIGH 18" RUBBER MEMBRANE NICKEL BRONZE GRATE AIR GAP 1" MIN. FLOOR DRAIN WITH FUNNEL DETAIL N.T.S.5 CONNECT TO TRAP PRIMER (CONDENSATE DRAIN LINE ONLY) NOTE: SLOPE ALL PIPING WITH 1/8" MINIMUM PITCH. 18 8 16 1" CONC. SLAB SEE FIGURE 1.0 FIGURE 1.0 FILL IN HOLE WITH FOAM & WHITE SILICONE AROUND SYRUP LINES SYRUP LINES CONC. SLAB 6" PVC CHASE 6" PVC CAP 90° ANGLE 3" HOLE N.T.S. SODA CHASE TERMINATION DETAIL 1 FINISHED FLOOR 2" FLOOR SINK TO GREASE WASTE MIN. 2" AIR GAP RIGID CONNECTION FE FE FE FE FE FE WH EX WH EX 5 20 EX CP 1 19 EX WC 1 3 LAV 1 TP 1 4 73 12 99 19 73 849 2 8A49 2 16 1 21D EX 21 EX EXISTING 1-1/2" CW INTO SPACE WITH EXISTING SHUT-OFF. FIELD VERIFY EXACT LOCATION. 34 C W H W H W H W FW CW CW CW ( E X ) C W CW CW C W HWR F W C W C W H W H W CWHW HW CWHW HW HW HW CW HWHW CW 107 8 9 5 13 13 13 13 13 13 7 6 10 11 HW R H W H W H W TP 14 TP 1 4 (TYP) 12 JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com G E N E R A L N O T E S 1.COORDINATE WATER LINES WITH ELECTRICAL CONTRACTOR PIPING SHALL NOT BE ROUTED OVER ELECTRICAL PANEL OR EQUIPMENT. 2.ALL BACKFLOW PREVENTERS SHOULD BE INSTALLED ABOVE THE KITCHEN OR RESTROOM DROP CEILING. IF BFP CANNOT BE INSTALLED ABOVE CEILING, IT MUST BE INSTALLED ABOVE THE MOP SINK, UNDER THE WATER HEATER PLATFORM. BFP SHOULD NOT INTERFERE IN ANY WAY WITH THE OPERATION OF THE KITCHEN. IF AN EXISTING BACKFLOW PREVENTER IS IN A LOCATION OTHER THAN WHAT IS SHOWN ON THESE DRAWINGS, CONTACT THE JIMMY JOHN'S CONSTRUCTION DEPARTMENT IMMEDIATELY FOR DIRECTION ON HOW TO PROCEED 3.ALL PLUMBING AND GAS LINES MUST BE RECESSED WITHIN WALL CAVITIES, UNLESS SPECIFICALLY NOTED OTHERWISE IN THE BLUEPRINTS. NO WATER LINES MAY RUN ALONG WALL. ALL EXISTING MUST BE MOVED 12" OFF OF WALL. IF CANNOT BE MOVED, LINE MUST BE FRAMED AROUND AND FINISHED PER WALL STYLE. ANY APPROVED EXPOSED DRAIN LINES MUST BE COPPER. NOTE: REFER TO PLUMBING RISERS SHEET P-3 FOR PIPE SIZING NOTE: CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECTED MOUNTED. REFERENCE SHEET MEP-3 FOR ALTERNATE COMPRESSOR INSTALLATION. FIELD VERIFY ALL EXISTING CONDITIONS AND UTILITIES LOCATIONS PRIOR TO BID. CONTRACTOR TO COORDINATE NECESSARY REQUIREMENTS WITH ALL OTHER TRADES. NOTIFY ENGINEER OF RECORD OF ANY DISCREPANCIES BETWEEN SITE CONDITIONS AND PLANS. KEYED NOTES PROVIDE 1/2" CW LINE WITH SHUT-OFF VALVE AT + 81" A.F.F. THRU WALL TO BE CARBONATOR (MOUNTED ABOVE BAG AND BOX). CONNECTIONS TO CARBONATOR TO BE PROVIDED BY BEVERAGE COMPANY. COCA-COLA TO PROVIDE 3/8" SHUTOFF TEE ON NON-CARBONATED WATER LINE WITHIN SODA CABINET. PLUMBER TO CONNECT TEA BREWER TO 3/8" SHUTOFF USING BRAIDED METAL HOSE. PROVIDE 1/2" WATER LINE STUB OUT AT 12 " A.F.F. FOR WATER CLOSET FLUSH TANK. 1/2" SOFT ANNEALED COPPER FROM TRAP PRIMER ABOVE CEILING DOWN IN WALL U/G TO F.D. EXISTING WATER HEATER TO BE RE-USED. EXISTING 1-1/2" WATER SERVICE. INSTALL SHUT-OFF VALVE, STRAINER, PRESSURE REDUCING VALVE (IF STATIC PRESSURE IS OVER 70PSI) AND BACKFLOW PREVENTER AS REQUIRED BY AHJ. FIELD VERIFY ALL EXISTING CONDITIONS AND ADJUST AS NECESSARY TO MEET DESIGN CRITERIA. ROUTING OF WATER LINES TO BE COORDINATED WITH MECHANICAL. TYPICAL. 1/2" CW DOWN AND THRU WALL TO ICE MAKER COMPRESSOR AT 67" AFF. RUN CW SUPPLY WITHIN WALL AND STUB OUT DIRECTLY BEHIND ICE MACHINE TO SHUT-OFF VALVE AND RUN 1/2" METAL BRAIDED HOSE FROM SHUT-OFF VALVE TO ICE MACHINE COMPRESSOR. FILTERED WATER LINE TO BE STUBBED OUT AT 67" A.F.F. TO SHUT OFF VALVE AND CONNECTED WITH A BRAIDED METAL HOSE, RUN WATER LINE IN WALL. WATER FILTER TO BE MOUNTED ON WALL AT 8'-0" A.F.F. PROVIDE SHUT OFF VALVE AT EACH SIDE OF FILTER. RECESS ALL SUPPLY LINES. REFER TO DETAIL SHEET P-2 FOR MORE INFORMATION. WATER LINES SHALL NOT BE ROUTED OVER ELECTRICAL PANELS. ROUTE 1/2" CW LINE BELOW SLAB AND STUB UP UNDER EQUIPMENT #73 FOR DIPPER WELL CONNECTION (EQUIPMENT #73). COORDINATE EXACT LOCATION WITH EQUIPMENT. PROVIDE SHUT-OFF VALVE AT STUB-UP. EXISTING FIXTURE TO REMAIN. MODIFY WATER CONNECTIONS AS NECESSARY TO MEET NEW DESIGN CRITERIA. P-1.2 PLANS PLUMBING DOMESTIC WATER PLAN 1/4" = 1'-0"A NORTH EX GAS METER 1 EXISTING 1-1/2" GAS INTO SPACE. FIELD VERIFY EXACT LOCATION AS NEC. EXISTING GAS LINE SERVING WATER HEATERS TO REMAIN. WH EX WH EX 3 2 2 4 JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com G E N E R A L N O T E S 1.ALL PLUMBING AND GAS LINES MUST BE RECESSED WITHIN WALL CAVITIES, UNLESS SPECIFICALLY NOTED OTHERWISE IN THE BLUEPRINTS. NOTE: REFER TO PLUMBING RISERS SHEET P-3 FOR PIPE SIZING NOTE: CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECTED MOUNTED. REFERENCE SHEET MEP-3 FOR ALTERNATE COMPRESSOR INSTALLATION. FIELD VERIFY ALL EXISTING CONDITIONS AND UTILITIES LOCATIONS PRIOR TO BID. CONTRACTOR TO COORDINATE NECESSARY REQUIREMENTS WITH ALL OTHER TRADES. NOTIFY ENGINEER OF RECORD OF ANY DISCREPANCIES BETWEEN SITE CONDITIONS AND PLANS. KEYED NOTES EXISTING GAS SERVICE TO REMAIN. MODIFY ENTRY POINT TO SPACE IF RUNNING OVERHEAD OF ELECTRICAL PANELS; MAINTAIN 1'-0" CLEARANCE. EXISTING GAS CONNECTION TO WATER HEATERS TO REMAIN AS IS. EXISTING GAS CONNECTION TO ROOFTOP UNIT TO REMAIN AS IS. P-1.3 PLAN GAS PLUMBING NORTH GAS PLAN 1/4" = 1'-0"A NOTE: ALL PIPES FULL SIZE OF UNIT OUTLET TO APPROVED RECEPTACLE PIPE SIZE SAME AS UNIT CONDENSATE DRAIN OPEN PIPE TO ATMOSPHERE B. 0.5 X STATIC PRESSURE IN PAN (INCHES). A. STATIC PRESSURE IN PAN (INCHES) UNIT AC CONDENSATE DRAIN ROOFING FLASHING ROOFING 5'-0" MIN. FROM INSIDE WALL 1. SPACE BLOCKING STANDS AT 6'-0" INTERVALS ON ROOF. 2. FOLD UP END OF SLIP SHEET AND NAIL TO BLOCK CONDENSATE PIPE NOTE: 4x6 "WOLMANIZED" BLOCKING - MASTIC TO ADDITIONAL ROOFING SHEET METAL STRAP WITH 1/4" DIA. x 2" LAG EACH SIDE, ALLOW FOR MOVEMENT B A 6" P-2 AND SCHEDULES PLUMBING DETAILS P L U M B I N G L E G E N D 1.ALL PLUMBING FIXTURES TO BE FULLY ACCESSIBLE TO INDIVIDUALS WITH DISABILITIES ACT OF 1990. FIXTURES AND THEIR INSTALLATION SHALL ALSO COMPLY WITH AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) PUBLICATION A117.1 - PROVIDING ACCESSIBILITY AND USABILITY FOR PHYSICALLY HANDICAPPED PEOPLE AND/OR GOVERNING CODES. - ALL PLUMBING FIXTURES EQUIPMENT, TRIM, & FITTINGS SHALL COMPLY WITH CITY REQUIREMENTS, AND FEDERAL REGULATIONS AND CODES, INCLUDING, BUT NOT LIMITED TO, WATER AND ENERGY CONSERVATION CODES. THE SCHEDULED AND/OR SPECIFIED PLUMBING FIXTURES AND EQUIPMENT REPRESENT THE MINIMUM CRITERIA AND SHALL BE THE BASIS FOR THE CONTRACTOR'S BASE BID. IF THE SCHEDULED OR SPECIFIED FIXTURES OR EQUIPMENT DO NOT COMPLY WITH GOVERNING CODES OR REGULATIONS IN ALL RESPECTS, THE CONTRACTOR SHALL PROVIDE AN ALTERNATE BID FOR COMPLYING FIXTURES, EQUIPMENT, TRIM, OR FITTINGS. THE ABSENCE OF AN ALTERNATE BID SHALL BE CONSTRUED TO MEAN THAT THE CONTRACTOR'S BID INCLUDES ALL COSTS NECESSARY TO MEET ALL REGULATIONS & CODES. 2.PROVIDE THERMOSTATIC MIXING VALVE AT ALL LAVATORIES AND HAND SINKS. PROVIDE ZURN TMV-1, 1 TO 15 GPM, NOT TO EXCEED 3 PSI, W/ UNION STOP CHECK INLETS, AND REMOVABLE STAINLESS STEEL STRAINERS, DIAL THERMOMETER AND DISCHARGE VALVE. SUPPLIES 110^F. 3. ALL ROOF PENETRATIONS SHALL BE APPROVED BY LANDLORD AND DONE IN ACCORDANCE WITH ROOF MANUFACTURERS RECOMMENDATIONS SO AS NOT TO VOID THE WARRANTY. NOTES: FLOOR CLEANOUT WALL CLEANOUT FLOOR SINK FLOOR DRAIN KITCHEN WASTE BELOW FLOOR SANITARY BELOW FLOOR FILTERED WATER HOT WATER VENT ABOVE FLOOR COLD WATER VENT BELOW FLOOR KW KW HUB DRAIN BALL VALVE TEMPERING VALVE BACKFLOW PREVENTOR FW FW V RESTROOM LAV HAND SINKWALL HUNG LAV [110° F] TEMPERED 1/2" THERMOSTATIC TEMPERING VALVE SEE SPECIFICATIONS 1/2" HW [140° F] FINISHED FLOOR [110° F] TEMPERED 1/2" THERMOSTATIC TEMPERING VALVE SEE SPECIFICATIONS 1/2" HW [140° F] SUPPLY FINISHED FLOOR 1 1/4" O.D. TAILPIECE 1 1/4" O.D. WASTE 1/2" CW SUPPLY 1 1/4" O.D. TAILPIECE 1 1/4" O.D. WASTE 1/2" CW SUPPLY NOTE: APPLICABLE TO ALL LAVS/HAND SINKS EXISTING WATER HEATER DETAIL N.T.S.6 TYPICAL VENT THRU ROOF N.T.S.4 TYPICAL UNIT CONDENSATE PIPING N.T.S.1 ICE MAKER DRAINAGE PIPING DETAIL N.T.S.5 8' - 0 " A . F . F . FILTERED WATER-OUTLET WATER SUPPLY-INLET CONDENSATE SUPPORT SIMILAR N.T.S.2 LOCAL MIXING VALVE DETAIL N.T.S.3 JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com PLUMBING FIXTURE SUPPLIER KEC DESIGN 301 MERCURY DRIVE SUITE 1 CHAMPAIGN, IL 61822 PHONE: 217.356.1640 FAX: 217.356.1661 EMAIL: projects@kecdesign.com PLUMBING FIXTURE SCHEDULE NOTE: THERE WILL BE ABSOLUTELY NO SUBSTITUTIONS ALLOWED FOR ANY PLUMBING PRODUCTS AS SPECIFIED. THIS INCLUDES ALL ZURN PRODUCTS. WATER FILTER DETAIL N.T.S.7 HOT WATER CIRCULATING PUMP NOTE: COORDINATE RINNAI HOT WATER HEATER INSTALLATION W/ ALL LOCAL HEALTH CODE AND OTHER CODE REQUIREMENTS. RINNAI PURCHASE CONTACT INFO: RICO VIGLIETTI, CORPORATE ACCOUNTS MANAGER - FOOD SERVICE EMAIL: jviglietti@rinnai.us OFFICE: 901-440-7389 PARTIAL WALL TO ENCLOSE MOP SINK FULL HEIGHT WALLS ON ONE SIDE OF MOP ENCLOSURE DROP CEILING AT 10' 4" AFF CONNECTION DETAIL Cold Water Supply Gas Supply Hot Water Supply Condensate Drain Line Recessed Back Into Wall And Stubs Out To Drain Into Mop Sink Below FIXTURE UNIT COUNT VENT TO SAN. WASTE MAIN 1" MIN AIR GAP OR AIR BREAK ICE MAKER DEEP SEAL TRAP DRAIN FROM COOLING UNIT FLOOR DRAIN FOR ICE BIN EXISTING WATER HEATER SCHEDULE (GAS) 1 INSTANT GAS WATER HEATER 2 INSTANT GAS WATER HEATER EXISTING GAS METER WH EX WH EX (199MBH) (199MBH) RTU 2 (HEAT PUMP) RTU 1-EX (108MBH) 19 EX 21D EX 21D EX 21 EX 19 20 EX WH EX WH EX TP 1 16 99 LAV 1 WC 1 TP 1 TP 1 107 CW( E X ) F W C W C W H W C W CW C W CW CW CWHW HW H W H W R HWR H W F W F W HW H W HW 73 73 FCO SQ 19 LAV 1 WCO - WC 1 FD 1SQ FD 1SQ73 73 FS 1 FS 1 99 FCO SQ 19 EX GT 1 FD 1SQ FS 1 FD 2SQ 21 EX 21D EX 20 EX CO EX FS 1107 FD 2RD EXISTING GAS TO WH'S FD 1RD 3"VTR DISCHARGE TO NEW FLOOR SINK. DISCHARGE TO NEW FLOOR SINK. 3"VTR 3"S S 3"SS 3"SS 3" G W 3" G W 3" S S ( E X ) 3" S S ( E X ) 3"S S 3"S S 3 " S S 3"G W 3"G W 3"GW 3"GW 2"V 2"V 2 " V 2 " V 2"V 3"S S ( E X ) 3"S S ( E X ) 3 " S S FCO SQ 2"V 3" S S 2 " V 2 " V 2"V 2"V 2"V 2 " V EXISTING CAPPED GAS LINE. 1-1/2" EXIST. GAS S A N I T A R Y W A S T E I S O M E T R I C N.T.S.B D O M E S T I C W A T E R I S O M E T R I C N.T.S.A P-3 ISOMETRICS PLUMBING JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com 1.SEE RESTAURANT EQUIPMENT SCHEDULE ON THE ARCHITECTURAL PLANS FOR EQUIPMENT PROVIDED BY OTHERS. THIS CONTRACTOR SHALL CONNECT WASTE, VENT, AND WATER TO EQUIPMENT FURNISHED BY OTHERS AND THIS CONTRACTOR SHALL INSTALL FAUCETS AND MISC. FITTINGS FOR A COMPLETE INSTALLATION. 2.ALL PLUMBING LINES MUST BE RECESSED WITHIN WALL CAVITIES UNLESS SPECIFICALLY NOTED OTHERWISE IN THE BLUEPRINTS. 3.CONNECT NEW DOMESTIC WATER TO EXISTING LINE. INSTALL BALL VALVE AS SHOWN. 4.EXTEND PLUMBING VENT UP THRU ROOF TO APPROVED VENT TERMINATION. LOCATE MINIMUM OF 10 FEET FROM ANY O.A. INTAKE AT THE CONDENSER UNITS. OFFSET AS NEEDED. 5.ALL EXPOSED PIPING TO PLUMBING FIXTURES SHALL BE CHROME PLATED. STOPS SHALL BE PROVIDED WITH REMOVABLE TYPE HANDLES. G E N E R A L N O T E S NOTE: A.THE PLUMBING CONTRACTOR SHALL SEE THAT THE PROPER GAS METER AND REGULATOR ARE INSTALLED BY THE UTILITY CO. AND PAY FOR ANY FEES CHARGED FOR THE INSTALLATION OF THE METER AND SERVICE LINES. GAS LINES SHALL EXTEND FROM THE METER TO ALL EQUIPMENT REQUIRING GAS. B.GAS PIPING: SCREWED STANDARD WEIGHT SCHEDULE 40 GALVANIZED STEEL CONFORMING TO ASTM A53 SPECIFICATIONS FOR GAS PIPING. C.GAS PIPE SHALL BE PROVIDED WITH SUITABLE DRIP LEGS ON ALL MAINS AND RISERS AT EQUIPMENT CONNECTIONS. ALL EQUIPMENT CONNECTIONS WILL BE PROVIDED WITH AN AGA APPROVED BUTTERFLY VALVE. CAP WHERE REQUIRED. NOTE: CONTRACTOR TO VERIFY EXACT GAS DELIVERY PRESSURE AT THE CUSTOMER SIDE OF METER IMMEDIATELY AFTER AWARD OF BID AND PRIOR TO COMMENCEMENT OF WORK. CONTRACTOR SHALL APPLY FOR GAS SERVICE IN A TIMELY MANNER. IF PRESSURE IS HIGHER THAN THE GAS PRESSURE USED TO SIZE THE GAS PIPING, CONTRACTOR SHALL PROVIDE A PRESSURE REGULATOR, IF LOWER, CONTACT THE PROFESSIONAL OF RECORD IMMEDIATELY FOR DIRECTION. IF THE PROFESSIONAL OF RECORD IS NOT CONTACTED, IT IS ASSUMED GAS PRESSURE IS VERIFIED AND ADEQUATE FOR THE SYSTEM DESIGNED ON THE DRAWINGS. NOTE: PIPING SIZED PER 2021 IFGC, TABLE 402.4(2), LOW PRESSURE GAS, TOTAL GAS DEMAND = 729,000 BTU/H DEVELOPED LENGTH = ±100'-0" TO METER (V.I.F.). ALL PIPING TO BE SCREWED STANDARD WEIGHT SCHEDULE 40 GALVANIZED STEEL PIPE UNLESS NOTED OTHERWISE. GAS I S O M E T R I C N.T.S.C MEP-1 GENERAL NOTES MECH./ELEC./PLUMB. 1.THE M/E/P CONTRACTORS SHALL REVIEW ENTIRE SET OF CONTRACT DOCUMENTS: INCLUDING BUT NOT NECESSARILY LIMITED TO ALL ARCHITECTURAL, ALL STRUCTURAL, ALL MECHANICAL, ALL ELECTRICAL, ALL PLUMBING, AND ENTIRE PROJECT MANUAL. ELECTRICAL CONTRACTOR SHALL ACKNOWLEDGE AND INCLUDE IN THE SCOPE OF WORK (CONTRACT) ALL CONDITIONS PERTINENT TO THE COMPLETION OF THE ELECTRICAL WORK. ELECTRICAL CONTRACTOR SHALL FULLY COORDINATE ELECTRICAL WORK WITH THE INSTALLATION OF WORK BY ALL OTHER TRADES AND MAKE NECESSARY FIELD ADJUSTMENTS AS REQUIRED TO ACCOMMODATE THE ELECTRICAL INSTALLATION. ALL OF THE ABOVE SHALL BE INCLUDED IN THE SCOPE OF WORK AT NO ADDITIONAL COST TO THE OWNER. 2.THE M/E/P CONTRACTORS SHALL CAREFULLY EXAMINE THE DRAWINGS AND SPECIFICATIONS, VISIT THE SITE OF THE WORK, AND FULLY INFORM HIMSELF AS TO ALL CONDITIONS AND MATTERS THAT CAN, IN ANY WAY, AFFECT THE WORK OR THE COST THEREOF, SHOULD THIS CONTRACTOR FIND DISCREPANCIES IN, OR OMISSIONS FROM, THE DRAWINGS, SPECIFICATIONS OR OTHER DOCUMENTS OR BE IN DOUBT AS TO THEIR MEANING, NOTIFY THE ARCHITECT/ENGINEER AT ONCE, IN WRITING, OF ANY DISCREPANCIES BETWEEN EXISTING CONDITIONS AND NEW WORK, OR BETWEEN ELECTRICAL WORK AND THE WORK OF OTHER TRADES PRIOR AND OBTAIN CLARIFICATION PRIOR TO SUBMITTING ANY BID. LACK OF SUCH NOTIFICATION SHALL BE CONSTRUED TO INDICATE NO DISCREPANCIES OR CONFLICTING EXIST. ADDITIONAL COMPENSATION WILL NOT BE GRANTED AFTER AWARD OF CONTRACT FOR ANY WORK REQUIRED TO COMPLY WITH THESE REQUIREMENTS. 3.THE DRAWINGS INDICATE THE DIAGRAMMATIC INTENT, GENERAL CHARACTER, REQUIREMENTS AND LOCATION OF THE WORK SHOWN AND INCLUDED. THE WORK INDICATED BUT HAVING MINOR DETAILS OBVIOUSLY OMITTED SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER. 4.THE CONTRACTOR IS REQUIRED TO BID, AS SPECIFIED, ON THE DRAWINGS WITHOUT DEVIATION. THIS CONTRACTOR IS INVITED TO SUBMIT SUBSTITUTIONS FROM THE BASE BID, ONLY IF THE SUBSTITUTIONS ARE APPROVED BY THE OWNER AND ENGINEER/ARCHITECT PRIOR TO SUBMITTING THE BID. 5.IT IS THE INTENT OF THESE DOCUMENTS THAT THE M/E/P CONTRACTOR PROVIDE ALL LABOR, MATERIAL, EQUIPMENT AND TOOLS FOR THE COMPLETE INSTALLATION OF ALL WORK SHOWN ON THE PLANS AND/OR DESCRIBED HEREIN, INCLUDING ALL DEVICES, CONTROLS AND APPURTENANCES REQUIRED TO SET NEW SYSTEMS INTO OPERATION. 6.THE CONTRACTOR SHALL VERIFY ALL MOUNTING, ALL ARRANGEMENTS, HEIGHTS AND LOCATIONS PRIOR TO ROUGH-IN. ANY MENTION OF A SPECIFIC MOUNTING ARRANGEMENT, HEIGHT OR LOCATION SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO VERIFY THE SPECIFIC REQUIREMENT FURNISHED OR THE OTHER TRADES WORKING IN THE SAME AREA. NO ADDITIONS TO THE CONTRACT SUM WILL BE PERMITTED FOR ITEMS INSTALLED IN WRONG LOCATIONS, IN CONFLICT WITH OTHER WORK, ETC. 7.SHOULD CONDITIONS NECESSITATE ANY REARRANGEMENTS, OR IF DUCTWORK CAN BE RUN TO BETTER ADVANTAGE, PREPARE AND SUBMIT SHOP DRAWINGS SHOWING THE CHANGES BEFORE PROCEEDING WITH THE WORK. IF SUCH CHANGES ARE APPROVED BY ARCHITECT/ENGINEER, THEY SHALL BECOME A PART OF THE CONTRACT AFTER THEIR APPROVAL. 8.UPON COMPLETION OF THE WORK, THE CONTRACTORS SHALL REVIEW AND CHECK THE ENTIRE PORTION OF WORK, CLEAN EQUIPMENT AND DEVICES, REMOVE SURPLUS MATERIALS AND RUBBISH FROM THE OWNER'S PROPERTY, LEAVING THE WORK IN NEAT AND CLEAN ORDER AND IN COMPLETE WORKING CONDITION. THE CONTRACTORS SHALL BE RESPONSIBLE FOR REMOVAL OF ANY CARTON, DEBRIS, ETC. FOR EQUIPMENT INSTALLED BY THE CONTRACTOR INCLUDING EQUIPMENT FURNISHED BY THE OWNER. THE ABOVE SHALL ALSO APPLY TO ALL EQUIPMENT FURNISHED BY OTHERS AND UNPACKED OR REMOVED FROM CARTON, BY THE CONTRACTORS. 9.THE M.E.P. CONTRACTORS IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, UNPACKING STORING SETTING IN PLACE, AND PROTECTING FROM DAMAGE, VANDALISM, THEFT OR WEATHER DURING CONSTRUCTION FOR ALL NEW EQUIPMENT FURNISHED BY THE ELECTRICAL CONTRACTOR. 10.THE M.E.P. CONTRACTORS SHALL PAY ALL PERMIT FEES, PLAN REVIEW FEES, LICENSE FEES, INSPECTIONS AND TAXES APPLICABLE TO THIS DIVISION AND SHALL BE INCLUDED IN THE BASE BID AS PART OF THIS CONTRACT. 11.THE M.E.P. CONTRACTORS SHALL GUARANTEE ALL WORK AND MATERIALS FOR A PERIOD OF ONE FULL YEAR AFTER FINAL ACCEPTANCE BY THE ARCHITECT/ENGINEER AND OWNER. 12.M.E.P. CONTRACTORS SHALL FURNISH CONTRACT RECORD DOCUMENTS TO THE ARCHITECT/ ENGINEER BEFORE FINAL PAYMENT WILL BE ISSUED. THE CONTRACT RECORD DOCUMENTS SHALL INDICATE THE DIAGRAMMATIC INSTALLED CONDITION AND BE IN REPRODUCIBLE DRAWING FORM. 13.THE WORK INSTALLED SHALL BE IN ACCORDANCE WITH ALL CITY CODES AND THE LOCAL UTILITY COMPANY'S REQUIREMENTS. 14.ALL EQUIPMENT/DEVICES SHALL BE NEW AND/OR FIRST QUALITY AND IS TO BEAR THE APPROPRIATE UL OR CSA APPROVED LABELS FOR SPECIFIC PURPOSE. 15.MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE TEMPERATURE CONTROL SYSTEM AS REQUIRED. 16.ALL THERMOSTATS SHALL BE MOUNTED AT +60" ABOVE FINISHED FLOOR (UNLESS OTHERWISE SPECIFIED). THERMOSTATS SHALL NOT INTERFERE WITH SHELVING, VENDING MACHINES, OTHER FIXTURES OR CONTROLS. 17.THE CONTRACTOR SHALL BE LICENSED, BONDED, INSURED AND CAPABLE OF PERFORMING QUALITY WORKMANSHIP. THIS CONTRACTOR GUARANTEES ALL OF HIS WORK AND MATERIALS FOR A PERIOD OF ONE (1) FULL YEAR AND FINAL ACCEPTANCE BY THE OWNER AND ENGINEER. 18.THE MECH & PLMG CONTRS SHALL SUBMIT SHOP DRAWINGS PRIOR TO THE START OF INSTALLATION FOR OWNER/ARCHITECT/ENGINEER APPROVAL. 19. THE M/E/P CONTRACTORS SHALL FURNISH AS-BUILT DRAWINGS TO THE OWNER/ENGINEER BEFORE FINAL PAYMENT WILL BE ISSUED. THE AS-BUILT DRAWINGS SHALL BE SUBMITTED IN REPRODUCIBLE FORM. 20.THE M/E/P CONTRACTORS SHALL BE RESPONSIBLE FOR THE STARTUP OF ALL HEATING, VENTING, AND AIR-CONDITIONING EQUIPMENT. 21. THE M/E/P CONTRACTORS SHALL PROVIDE A COMPETENT OPERATING TECHNICIAN TO INSTRUCT THE OWNER IN THE OPERATION AND MAINTENANCE OF THE NEW EQUIPMENT. 22. DO ALL CUTTING AND PATCHING (TO ORIGINAL STATE) OF BUILDING MATERIALS AS REQUIRED FOR INSTALLATION OF A COMPLETE WORKABLE SYSTEM. 23. THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS. 24. PLUMBING CONTRACTOR SHALL VERIFY EXACT LOCATION OF ALL EXISTING SANITARY, STORM AND WATER SUPPLY ON THE SITE PRIOR TO THE PERFORMANCE OF ANY WORK. 25. PLUMBER SHALL PROVIDE SERVICE VALVES AT ALL BRANCH SUPPLY PIPING. SUCH SERVICE VALVES SHALL BE LOCATED ACCESSIBLY ABOVE THE CEILING. 26.PLUMBER SHALL BEFORE PLACING WATER SYSTEM IN OPERATION, CHLORINATE ENTIRE SYSTEM IN ACCORDANCE WITH THE REQUIREMENTS OF THE CITY PLUMBING CODES SUPPLY CERTIFICATE OF COMPLIANCE. 27.ALL NEW SANITARY PIPING SHALL BE GIVEN A FULL STATIC PRESSURE TEST. METHOD OF TEST AND REQUIREMENTS TO BE MET SHALL BE AS PER THE CITY. 28. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR THE PUMPING AND DRAINING OF TRENCHES OR PITS NECESSARY FOR THE INSTALLATION OF HIS WORK. 29.THE GENERAL CONDITIONS AND SUPPLEMENTARY GENERAL CONDITIONS SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. 30.ALL WORK TO BE IN ACCORDANCE WITH THE RULES AND REGULATION OF THE CITY AUTHORITIES AND THE MOST RECENT EDITION OF NATIONAL ELECTRIC CODE. 31.CONTRACTOR SHALL FILE PLANS WITH AND OBTAIN APPROVALS FROM MUNICIPAL AGENCIES. ALL PERMITS AND CERTIFICATES OF INSPECTION SHALL BE OBTAINED AND PAID FOR BY THE CONTRACTOR. PERTINENT CERTIFICATES SHALL BE DELIVERED TO THE OWNER'S REPRESENTATIVE, PRIOR TO FINAL BILLING. 32.ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES; AN ACCURATE RECORD OF ALL WORK AS ACTUALLY INSTALLED. UPON COMPLETION OF THE WORK AND BEFORE FINAL PAYMENT IS AUTHORIZED, SHALL TURN OVER TO THE OWNER'S REPRESENTATIVE A RECORD SET OF PRINTS SHOWING THESE CHANGES. 33.SUBMIT MATERIAL LISTS AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE OWNER'S REPRESENTATIVE FOR REVIEW. SUBMITTALS SHALL BE IN ACCORDANCE WITH GENERAL CONDITIONS AND SHALL BEAR THE STAMP OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED AND APPROVED THEM. LACK OF SUCH CONTRACTOR'S APPROVAL WILL BE CAUSE FOR REJECTION WITHOUT REVIEW BY THE OWNER. 34.THIS CONTRACTOR SHALL DO ALL CUTTING, CHASING, OR CHANNELING AND PATCHING REQUIRED FOR ANY WORK HEREIN SPECIFIED. ALL OPENINGS THROUGH STRUCTURALLY SUPPORTED SLABS MUST BE CORE-BORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND AT LEAST 2" AFF. ALL SLEEVES, OPENINGS, ETC. THROUGH FIRE RATED WALLS AND FLOORS SHALL BE SEALED AFTER CONDUIT INSTALLATION TO RETAIN FIRE RATING. 35.ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIR. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL, SUCH AS CHANNELS, RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK AND SHALL BE SECURED TO THE BUILDING STRUCTURE, NOT TO PIPING OR DUCTWORK. ALL CONDUIT SHALL BE CONCEALED WHERE POSSIBLE. EXPOSED CONDUIT SHALL BE RUN IN STRAIGHT LINES PARALLEL WITH OR AT RIGHT ANGLES TO COLUMN LINES AND SEPARATED AT LEAST 3" FROM WATER LINES WHEREVER THEY RUN ALONG SIDE OR ACROSS SUCH LINES. 36.EVERY PART OF THE INSTALLATION SHALL BE TESTED, OPERATED AND LEFT IN PERFECT WORKING ORDER. SHOULD TESTING REVEAL ANY OTHER DEFECTS, PROMPTLY CORRECT SUCH DEFECTS AND RERUN TESTS UNTIL THE ENTIRE INSTALLATION IS SATISFACTORY IN ALL RESPECTS. 37.GUARANTEE CONTRACTOR IS TO GUARANTEE ALL WORK FOR A PERIOD OF ONE YEAR AFTER THE DATE OF ACCEPTANCE OF THE PROJECT BY THE OWNER. IT IS UNDERSTOOD BY HIS ACCEPTANCE OF THE CONTRACT THAT THIS CONTRACTOR WILL MAKE GOOD ANY AND ALL WORK WHICH IN ANY WAY HAS BECOME DEFECTIVE AS TO THE QUALITY OF MATERIALS AND WORKMANSHIP FOR ANY CAUSE OTHER THAN ORDINARY WEAR AND TEAR. FOR THE SAME PERIOD, ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO THE PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM. 38.THE CONTRACTOR, BEFORE FINAL ACCEPTANCE BY THE OWNER WILL BE GRANTED, SHALL CLEAN ALL LIGHTING FIXTURES, DEVICE PLATES, SERVICE FITTINGS AND OTHER ITEMS FURNISHED UNDER THIS CONTRACT. HE SHALL INSURE THAT ALL DIRECTORIES ARE IN PLACE WITH COMPLETED OR REVISED SCHEDULES AND ALL IDENTIFICATIONS AND MARKINGS OF EQUIPMENT, CABLES AND OTHER ITEMS ARE COMPLETED. 39.THIS CONTRACTOR SHALL COORDINATE SEQUENCE OF WORK WITH ALL OTHER TRADES. CONTRACTOR SHALL VERIFY VOLTAGE OF MECHANICAL EQUIPMENT AND FLUORESCENT FIXTURE BALLASTS, PRIOR COMMENCING ANY WORK. NO REMOVALS SHALL BE MADE WITHOUT OWNER'S APPROVAL. ALL EXISTING EQUIPMENT, MATERIALS, ETC. THAT ARE NOT TO BE REUSED SHALL BE REMOVED COMPLETELY AND DISPOSED OF BY THIS CONTRACT0R. 40.THIS CONTRACTOR SHALL MAKE ARRANGEMENTS FOR TEMPORARY POWER AND SHALL PAY THE COST FOR THE UTILITY CONNECTION AND SHALL BE RESPONSIBLE FOR THE PROPER MAINTENANCE OF THE TEMPORARY WORK AND FOR THE REMOVAL OF SAME. CONTRACTOR SHALL PAY ALL UTILITY CHARGES IN CONNECTION WITH THE TEMPORARY POWER. CONTRACTOR SHALL PROVIDE GROUND FAULT PROTECTION FOR ALL POWER EQUIPMENT USED ON THE PREMISES DURING CONSTRUCTION. 41.SCOPE OF WORK CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT AND FEES REQUIRED TO COMPLETELY INSTALL, TEST AND PLACE THE HEREIN SPECIFIED EQUIPMENT, COMPONENTS, CONTROLS, AND SYSTEMS IN SERVICE. COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM COMPLETE UTILITY MOTOR WIRING SYSTEMS (EXCEPT AS NOTED) COMPLETE LIGHTING FIXTURE INSTALLATION COMPLETE TELEPHONE CONDUIT SYSTEM. CONDUIT FROM POINT OF CONNECTION TO LANDLORD'S SYSTEM AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS, FURNISHED BY THE OWNER PROVISIONS FOR FIRE ALARM/SMOKE EVACUATION SYSTEM AND EXTENSION TO LANDLORD'S SYSTEM TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION TESTING OF ALL ELECTRICAL EQUIPMENT WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATED OF PROJECT CLOSE-OUT 42.ELECTRICAL SERVICE PROVIDE ELECTRICAL AS INDICATED ON THE DRAWING. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR THE POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE ENTIRE INSTALLATION WITH THE POWER COMPANY. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL UTILITY FOR INSTALLATION OF METERING. 43.CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE UTILITY FOR TELEPHONE SERVICE TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR UTILITY COMPANY WIRES. COORDINATE INSTALLATION OF TELEPHONE WORK AND INSTALL ALL CONDUIT FOR TELEPHONE SYSTEM. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. PROVIDE INTERIOR TYPE 4-D PLYWOOD O SERVE AS TELEPHONE TERMINAL BOARD - VERIFY EXACT LOCATION WITH JIMMY JOHN'S. 44.FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. 44.1 THE WORD "PROVIDE" AS USED HEREIN MEANS TO FURNISH AND INSTALL COMPLETE. 44.2 MATERIALS, PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. 44.3 EQUIPMENT SHALL BE SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE AND THE CITY CODES. 45.CONDUIT SHALL BE STANDARD STEEL, RIGID, IMC OR EMT (THIN WALL) ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS, EXCEPT AS OTHERWISE APPROVED BY OWNER'S REPRESENTATIVE. 46.RACEWAYS SHALL BE SURFACE METAL TYPE OF THE SIZE AND CHANNEL REQUIRED FOR SERVICE, CONSTRUCTED OF GALVANIZED STEEL WITH SNAP-ON COVERS, WITH 1/8" MOUNTING SCREW KNOCKOUTS IN BASE APPROXIMATELY 8" O.C. PROVIDE FITTINGS INDICATED WHICH MATCH AND MATE WITH RACEWAY. FINISH WITH MANUFACTURER'S STANDARD PRIME COATING SUITABLE FOR PAINTING. 47.ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600V INSULATION: 47.1 #10 AND SMALLER - SOLID WITH SINGLE BRAID OR STRANDED # 8 AND LARGER - STRANDED WITH AT LEAST DOUBLE BRAID. MINIMUM WIRE SIZE SHALL BE #12, EXCEPT #14 MAY BE USED FOR CONTROL APPLICATIONS. 47.2 ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UNBROKEN PACKAGES. 47.3 GENERAL WIRING SHALL HAVE THW, THHN OR THWN INSULATION. 47.4 ALUMINUM CONDUCTORS ARE NOT PERMITTED FOR BRANCH CIRCUIT WIRING. 47.5 WIRES SHALL BE COLOR CODED IN KEEPING WITH NEC STANDARDS 48.OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR SHERARDIZED STEEL, KNOCK-OUT TYPE W/FIXTURE STUDS AS REQ. JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE AND SIZE. 49.WIRING DEVICES WALL SWITCHES, SINGLE POLE, DOUBLE POLE, AND THREE WAY SHALL BE GENERAL DUTY, FLUSH, TOGGLE SWITCHES; SPECIFICATION GRADE, 20A, 120/277V, WITH SCREW TERMINALS: MANUFACTURES SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. GENERAL DUTY DUPLEX RECEPTACLES SHALL BE 2-POLE, 3-WIRE GROUNDING TYPE, SPECIFICATION GRADE, 20A, 125V, NEMA 5-20R UNLESS OTHERWISE INDICATED. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. GROUND FAULT INTERRUPTER RECEPTACLE SHALL BE GENERAL DUTY, DUPLEX RECEPTACLES, GROUND FAULT CIRCUIT INTERRUPTER, FEED-THROUGH TYPE, CAPABLE OF PROTECTING CONNECTED DOWNSTREAM RECEPTACLES ON A SINGLE CIRCUIT, GROUNDING TYPE UL-RATED CLASS A, GROUP 1, 20A, 120V, 60 HZ; WITH SOLID-STATE GROUND FAULT SENSING AND SIGNALING; WITH 5 MILLIAMPERES GROUND-FAULT TRIP LEVEL; IN NEMA 5-15R CONFIGURATION. MANUFACTURERS SHALL BE HUBBELL, BRYANT, PASS AND SEYMORE, OR LEVITRON. DUPLEX ISOLATED GROUND TYPE RECEPTACLE SHALL BE 2-POLE, 4-WIRE, 15A STRAIGHT BLADE DEVICE WITH SEPARATE ISOLATED GROUND AND BUILDING GROUND CONNECTIONS, IN NEMA 5-15R CONFIGURATION, AS MANUFACTURED BY HUBBELL IG-5362. ANY RECEPTACLE THAT IS INSTALLED AT OR BELOW 37 INCHES SHALL BE INSTALLED GROUND UP AND ANY RECEPTACLE THAT IS INSTALLED AT OR ABOVE 38 INCHES SHALL BE INSTALLED GROUND DOWN. 50.THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTORS. ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL THE REQUIRED CITY CODES, NEC CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE A PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL CITY CODES. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH SECTION 250, TABLE 250-66 OF THE NATIONAL ELECTRICAL CODE. PROVIDE CONDUIT TO GROUND WIRE FROM DAMAGE TO AN AREA 6 FT. ABOVE FLOOR. PROTECT MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO MAINTAIN CONTINUITY OF MECHANICAL AND ELECTRICAL GROUND THROUGHOUT ENTIRE SYSTEM. GROUND ALL 3 WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND NEUTRAL FROM THE TRANSFORMER CONNECTED TO WATER LINE. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON-METALLIC CONDUIT. 51.LIGHTING PANEL BOARD SHALL BE 3-PHASE, 4-WIRE DISTRIBUTED PHASE TYPE WITH SOLID NEUTRAL GROUND LUG, GROUND BUS AND NUMBER OF CIRCUIT BREAKERS AS SHOWN ON THE PANEL SCHEDULE. BUSWAYS SHALL BE HARD DRAWN COPPER. CABINET SHALL BE CONSTRUCTED OF CODE GAUGE STEEL WITH HINGED DOOR HAVING DIRECTORY CARD, NEATLY AND PROPERLY INSCRIBED AND SET IN FRAME WITH TRANSPARENT COVER. ALL BREAKERS SHALL BE BOLTED TYPE, THERMAL MAGNETIC WITH ALL TWO OR THREE POLE BREAKERS HAVING COMMON TRIP. CIRCUIT BREAKERS SHALL BE RATED FOR MINIMUM 10,000 AMP SYMMETRICAL SHORT CIRCUIT CURRENT AT 120/208V. CIRCUIT BREAKERS SERVING LIGHTING CIRCUITS SHALL BE RATED FOR SWITCH SERVICE. PANELBOARDS AND BREAKERS SHALL BE AS MANUFACTURED BY SQUARE-D OR EQUAL. PANEL SHALL BE CIRCUITED SO THAT THE LOAD IS DISTRIBUTED EVENLY ACROSS ALL THREE PHASES. 52.PROVIDE SAFETY AND DISCONNECT SWITCHES, FUSED OR NON-FUSED, AS CALLED FOR ON DRAWING AND AS REQUIRED BY THE CITY. SWITCHES SHALL BE HEAVY DUTY, LOAD AND HORSEPOWER RATED AS MANUFACTURED BY SQUARE-D, GENERAL ELECTRIC, OR EQUAL. SWITCH ENCLOSURE TO BE SUITABLE FOR APPLICATION. FURNISH AND INSTALL DUAL ELEMENT CURRENT LIMITING FUSES OF TYPE AND AMPACITY DESIGNED TO PROTECT SYSTEM AGAINST AVAILABLE SHORT CIRCUIT FAULT CURRENT. 53.IF REQUIRED: PROVIDE DRY-TYPE TRANSFORMER WHICH SHALL BE COMPLETELY ENCLOSED EXCEPT FOR VENTILATING OPENINGS WITH KVA AND VOLTAGE RATINGS AS CALLED FOR ON THE DRAWING AS MANUFACTURED BY SQUARE-D. TRANSFORMER SHALL HAVE A MINIMUM OF CLASS 155 INSULATION SYSTEM, AND A MINIMUM OF (4) 2-1/2 % TAPS BELOW AND (2) 2-1/2 % TAPS ABOVE RATED PRIMARY VOLTAGE. SOUND LEVEL SHALL BE LOW AND INSTALLATION SHALL INCLUDE VIBRATION DAMPENING MOUNTS AND FLEXIBLE STEEL CONDUIT FOR PRIMARY AND SECONDARY. 54.LIGHTING FIXTURES THE CONTRACTOR SHALL PROVIDE A NEW LIGHTING FIXTURE OF THE TYPE SPECIFIED FOR EACH LIGHTING OUTLET SHOWN WITH COMPLETE LAMPS OR TUBES. ALL FIXTURES SHALL BE HUNG AND MOUNTED IN PLACE, PROPERLY WIRED, TESTED AND LEFT READY FOR OPERATION. 55.PAINTING OF ELECTRICAL CONDUITS, ETC. IF REQUIRED, WILL BE BY GENERAL CONTRACTOR. 56.RECEPTACLES, SWITCHES, AND COVER PLATES IN CUSTOMER AREAS ARE TO MATCH THE SURROUNDING WALL COLOR. ALL RECEPTACLES AND SWITCHES IN PREP AREA AND RESTROOMS ARE TO BE WHITE. ALL COVER PLATES IN THE PREP AREA AND RESTROOMS NEED TO BE STAINLESS STEEL. 57.FINALLY IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETE IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS, BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING IS APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLES OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ADDITIONAL COST. 58.NO ROMEX OR BX WILL BE PERMITTED. 59.ALL WIRE SHALL BE INSTALLED IN THIN WALL (E.M.T.) CONDUIT UNLESS OTHERWISE NOTED. MINIMUM SIZE SHALL BE 3/4" EXCEPT FOR DROPS FOR DEVICES, SWITCH LEGS, TEMPERATURE CONTROL CONDUITS, WHERE INDICATED OR AS CALLED FOR ON DRAWINGS. 60.ALL THIN WALL FITTINGS SHALL BE OF THE STEEL COMPRESSION GLAND TYPE. 61.ALL UNDER FLOOR, UNDERGROUND OR EXPOSED-TO-WEATHER CONDUIT SHALL BE HEAVY WALL GALVANIZED RIGID STEEL. (G.R.S.), MINIMUM 3/4". 62.ALL CONDUITS 2" OR LARGER SHALL BE GALVANIZED RIGID STEEL OR INTERMEDIATE METAL CONDUIT (I.M.C.). 63.ELECTRICAL CONTRACTOR SHALL INSTALL SIZE OF CONDUIT SHOWN AND AS SCHEDULED ABOVE AND SHALL NOT REDUCE SIZING OF CONDUITS TO SUIT WIRE FILL CAPACITY. 64.ALL CONDUIT FASTENERS, STRAPS, SUPPORTS ETC. MUST BE "BOLT-ON" GALVANIZED STEEL ON EXPOSED CONSTRUCTION AND IN WET AREAS. ABOVE SUSPENDED CEILINGS WILL BE PERMITTED. ALL FASTENERS, SNAP-ON BLACK METAL "CADDY" CLIPS IN METAL PARTITION WALLS AND STRAPS, CLIPS, ETC. SHALL BE UL LISTED FOR THEIR USE. 65.NO CONDUITS SHALL BE ROUTED THROUGH HVAC AIR DUCTS. 66.ALL CONDUIT RACEWAYS SHALL BE CONCEALED IN OR WITHIN: WALLS, CEILING CAVITY, ROOF CONSTRUCTION (WHERE APPROVED), SLAB, GRADE, ETC. UNLESS OTHERWISE NOTED. ANY RACEWAY THAT IS TO BE ROUTED EXPOSED SHALL BE APPROVED BY THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. ALL CONDUIT SHALL BE ROUTED PARALLEL OR PERPENDICULAR TO WALLS AND STRUCTURAL MEMBERS WITH 90° F BENDS WHERE REQUIRED AND SHALL BE RACKED. PULL AND JUNCTION BOXES SHALL BE HELD TO A MINIMUM. 67.NO WIREWAY, THROUGH OR JUNCTION SHALL BE UTILIZED WHERE MORE THAN 8 CONDUITS ARE ENTERING OR LEAVING. MULTIPLE WIREWAYS, TROUGHS OR JUNCTIONS SHALL BE UTILIZED. IN NO CASE SHALL FEED OR CONDUIT OR CABLING BE MIXED WITH BRANCH CONDUIT. 68.NO CONDUITS SHALL BE ROUTED ON ROOF. ELECTRICAL CONTRACTOR SHALL COORDINATE ROOF PENETRATIONS WITH MECHANICAL PIPE CURBS. WHERE CONDUIT MUST BE RUN ON ROOF, IT SHALL BE RACKED WITH OTHER TRADES WHERE POSSIBLE OR PROVIDED WITH ITS OWN ROOF RACK SUPPORT SYSTEM WITH PROPER ROOF PLATE SO AS NOT TO CAUSE DAMAGE TO ROOF COVERING. 69.ELECTRICAL CONTRACTOR SHALL FIREPROOF ALL CONDUIT OPENINGS BETWEEN FLOORS AND ANY INTERSPACE FIRE SEPARATION BLOCK WALLS WITH AN ENGINEER APPROVED UL LISTED FIRE RETARDANT MATERIAL. 70.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL SLEEVES THRU WALLS AND CORING THRU FLOORS. ELECTRICAL CONTRACTOR SHALL WEATHERPROOF ALL PENETRATIONS THRU FOUNDATION AND EXTERIOR WALLS. 71.FINAL EQUIPMENT CONNECTION TO PILOT CONTROL DEVICES SHALL BE MADE WITH 1'-0" MINIMUM LENGTH OF FLEXIBLE CONDUIT CONNECTION (IE. SOLENOID VALVES, MOTORIZED DAMPERS, ETC.). 72.ELECTRICAL CONTRACTOR SHALL PROVIDE LOCAL LOW VOLTAGE SWITCHING IN LIEU OF LINE VOLTAGE SWITCHING FOR 277 CIRCUITS IF REQUIRED BY LOCAL CODE. ELECTRICAL CONTRACTOR SHALL PROVIDE BARRIERS TO SEPARATE DIFFERENT PHASES IN 277 VOLT GANGED SWITCH BOXES. M E C H A N I C A L , E L E C T R I C A L , P L U M B I N G G E N E R A L N O T E S JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com MEP-2 SPECIFICATIONS MECH./ELEC./PLUMB. DUPLEX RECEPTACLE, 208V, 20 AMP RATED 18" A.F.F. UNLESS OTHERWISE NOTED. MOUNTED IN COMMON JUNCTION BOX. DESCRIPTIONSYMBOL J J T SYMBOL DESCRIPTIONMATERIALS: 1.ALL MATERIALS SHALL BE NEW, OF FIRST QUALITY AND UL LISTED FOR THE SPECIFIC DESIGN PURPOSE. 2.SANITARY, VENT AND STORM LINES SHALL BE CAST IRON AND AS PERMITTED BY THE CITY AUTHORITIES. PVC NOT PERMITTED WHERE DISCHARGE EXCEEDS 90°F 3.ALL WATER AND WASTE PIPING TO BE RUN ON WARM SIDE OF INSULATION. 4.DOMESTIC SUPPLY PIPING LOCATED ABOVE THE FINISHED FLOOR SHALL BE TYPE "L" COPPER. UNDERGROUND DOMESTIC SUPPLY PIPING SHALL BE TYPE "K" COPPER. 5.THREADED FITTINGS ON GALVANIZED STEEL PIPING SHALL BE 150# CLASS GALVANIZED MALLEABLE IRON FITTING CONFORMING TO ASTM A-197 SPECIFICATION. 6.FURNISH AND INSTALL UNIONS WHERE INDICATED OR NECESSARY FOR REPAIR OR SERVICE. UNIONS 2" AND SMALLER SHALL BE STANDARD GROUND JOINT BRASS TO IRON SEAT, MALLEABLE IRON, SCREWED. UNIONS 2-1/2" AND LARGER SHALL BE STANDARD CAST IRON FLANGED UNIONS 125# CLASS. 7.VALVES SHALL BE MANUFACTURED BY CRANE, STOCKHAM. 8.DOMESTIC HOT WATER SUPPLY PIPING SHALL BE INSULATED WITH ONE OF THE FOLLOWING: (INSTALL AS RECOMMENDED BY MANUFACTURER). A.1" THICK PREFORMED FIBERGLASS WITH "K" FACTOR OF 0.23 MAXIMUM AT 75°F. MEAN TEMPERATURE. JACKET TO BE FACTORY APPLIED KRAFT PAPER WITH VAPOR BARRIER. B.1" THICK MOLDED RIGID PHENOLIC FOAM WITH "K" FACTOR OF 0.23 MAXIMUM AT 78°F MEAN TEMPERATURE WITH FACTORY APPLIED LAMINATED ALUMINUM FOIL AND WHITE KRAFT PAPER VAPOR BARRIER JACKET. 9.DOMESTIC COLD WATER PIPING AND SUSPENDED HORIZONTAL STORM SEWERS AND ALL FITTINGS SHALL BE INSULATED WITH: (INSTALL AS RECOMMENDED BY MANUFACTURER). A. 1/2" THICK INSULATION W/ FRK WRAP FOR PIPING UP TO 1-1/4" DIAMETER. B. 1" THICK AT STORM C. SEAL BUTT & LONGITUDIAL JOINTS W/ WATERPROOF SEALANT. 10.PIPE INSULATION AT ALL PIPE HANGERS SHALL CONSIST OF INSUL-SHIELD FIBERGLASS PIPE SUPPORTS AS MANUFACTURED BY INSUL-COUSTIC OR ARCHITECT/ENGINEER APPROVED EQUAL. 11.HANGERS SHALL BE OF STANDARD WEIGHT STEEL OR IRON ROD AND RING OR CLEVIS TYPE. PROCEDURES: 1.ALL SUSPENDED HORIZONTAL PIPING SHALL BE SUPPORTED BY HANGERS SPACED NO FURTHER THAN 8' - 0" APART (4' -0" APART FOR PVC PIPING). NO PIPING SHALL BE SELF-SUPPORTING NOR BE SUPPORTED FROM EQUIPMENT CONNECTIONS AND PER U.P.C. TABLE 3-2. 2.ALL PARALLEL PIPES [TWO (2) OR MORE] SHALL BE SUPPORTED ON A CHANNEL TYPE TRAPEZE HANGER. 3.SUPPORTS AND HANGERS SHALL BE INSTALLED TO PERMIT FREE EXPANSION AND CONTRACTION IN PIPING SYSTEMS UNLESS PIPE REQUIRES FIRM ANCHOR CONTROL. 4.HORIZONTAL SOIL OR WASTE LINES SHALL BE AT A SLOPE OF NOT LESS THAN AS NOTED IN NOTE #(17) BELOW AND SHALL BE HELD CLOSE TO THE CONSTRUCTION TO MAINTAIN A MAXIMUM OF HEAD ROOM. ALL CHANGES OF DIRECTION AND JUNCTIONS SHALL BE MADE WITH "Y" FITTINGS AND 1/8" BENDS. NO LINES OF ANY KIND SHALL BE LOCATED BELOW FREEZERS. ALL DRAIN LINES SHALL BE PROTECTED FROM FREEZING. 5.HOT AND COLD WATER PIPING SHALL BE PROPERLY PITCHED TO LOW POINTS IN THE SYSTEM WHERE DRAINS SHALL BE INSTALLED. 6.CLEANOUTS SHALL BE PLACED AT ALL DEAD ENDS, AT CHANGES OF DIRECTION, AT 50'-0" INTERVALS ON HORIZONTAL RUNS, OUT OF HIGH TRAFFIC AREAS, (NOT UNDER CASES) ETC. WHERE CLEANOUTS OCCUR IN CONCEALED SPACES, THEY SHALL BE PROVIDED WITH EXTENSIONS TO FLOOR ABOVE OR TO WALLS. A HAND-HOLE TEST TEE SHALL BE PLACED AT THE BASE OF EACH STACK. 7.VENT STACKS EXTENDING UP THROUGH THE ROOF SHALL BE FLASHED WITH SIX POUND SHEET LEAD. FLASHING SHALL EXTEND 12" IN ALL DIRECTIONS FROM THE VENT, CARRIED OVER AND TURNED DOWN THE INSIDE OF THE VENT. ALL SEAMS AND JOINTS OF FLASHING SHALL BE SOLDERED AND PROVEN WEATHERTIGHT. EXTEND VENTS A MIN. OF 12" ABOVE ROOF, AND 30" AWAY FROM PARAPET. 8.ALL SUPPLY PIPING TO BE RUN OVERHEAD, UNLESS NOTED OTHERWISE. 9.ALL SUPPLY PIPING TO BE A MINIMUM OF 1/2" DIA. 10.EACH FIXTURE WILL HAVE A 3/4" X 12" AIR CHAMBER. 11.PROVIDE SERVICE VALVE AT BRANCHES AND AT ALL APPLIANCES. 12.ALL FIXTURES WILL BE FURNISHED WITH INTEGRAL STOPS. 13.BURIED SANITARY AND WASTE LINES WILL BE AS NOTED ON PLUMBING PLAN.. 14.ALL FLOOR DRAINS AND FIXTURES TO BE VENTED IN ACCORDANCE WITH LOCAL CODES. 15.ALL HORIZONTAL VENT PIPING SHALL BE RUN ABOVE FINISHED CEILINGS AND SLOPED UP TOWARD MAIN STACK. 16.THE PLUMBING CONTRACTOR WILL NOT INSTALL COMBUSTIBLE PIPING MATERIAL IN OR THROUGH FIRE RATED ASSEMBLIES. 17.HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS THAN 1/4" PER FOOT FOR PIPING 3" DIA. AND UNDER. 18.HORIZONTAL DRAINAGE PIPING SHALL BE PITCHED NOT LESS THEN 1/4" PER FOOT FOR PIPING 4" DIA. AND OVER. 19.ALL EQUIPMENT DEVICES SHALL BE INSTALLED WITH UNIONS IN SUCH A MANNER TO FACILITATE EASY REMOVAL AND MAINTENANCE OF EQUIPMENT WITHOUT DISRUPTING SERVICE AND CAUSING MAJOR PIPING REVISIONS. 20.ALL CONNECTIONS BETWEEN DISSIMILAR METALS SHALL BE MADE WITH DIELECTRIC UNIONS OR COUPLINGS. 21.JOINTS IN COPPER TIUBING SHALL BE MADE BY THE APPROPRIATE USE OF APPROVED COPPER OR COPPER ALLOYFITTINGS. SURFACES TO BE JOINED BY SOLDERING SHALL BE CLEANED BRIGHT BY MANUAL OR MECHANICAL MEANS. THE JOINTS SHALL BE PROPERLY FLUXED WITH AN APPROVED TYPE-FLUXAND MADE UP WITH APPROVED SOLDE. SOLDER AND FLUXES SHALL BE MANUFACTURED TO APPROVED STANDARDS. SOLDER AND FLUXES WITH A LEAD CONTENT THAT EXCEEDS TWO-TENTHS (.20) OF 1 PERCENT SHALL BE PROHIBITED IN PIPING SYSTEMS USED TO CONVET POTABLE WATER. NOTE: 1.RECEPTACLES, SWITCHES, AND COVER PLATES IN DINING ROOM ARE TO MATCH THE SURROUNDING WALL FINISHES. 2.ALL RECEPTACLES AND SWITCHES IN PREP AREA AND RESTROOMS NEED TO BE WHITE. 3.ALL COVER PLATES IN THE PREP AREA AND RESTROOMS NEED TO BE STAINLESS STEEL. 4.ON ALL CONDUIT RUNS: A.ARROW INDICATE HOME RUN TO PANEL. B.SLASHES INDICATE QUANTITY OF WIRES. 1. SHORT SLASHES INDICATE PHASE AND SWITCH LEGS. 2. LONG SLASHES INDICATE NEUTRAL CONDUCTORS. 3. LONG SLASHES WITH DOT INDICATE GREEN GROUND CONDUCTORS. 5. DOTTED SYMBOL ON PLAN INDICATES EXISTING FIXTURE, DEVICE OR EQUIPMENT. REFER TO DEMOLITION NOTES AND SYMBOLS FOR FIXTURE INFORMATION. GROUND INDICATES GREEN GROUND CONDUCTOR CONNECTED TO EQUIPMENT AND PANEL GROUND FAULT INTERRUPTER FURNISHED AND INSTALLED FURNISHED BY OTHERS INDICATES FIXTURE CONNECTED TO EMERGENCY SERVICE ELECTRICAL CONTRACTOR ABOVE FINISHED FLOORA.F.F. E.C. EM F.B.O. F & I GFI GRND NL WP NIGHT LIGHT, 24 HOUR OPERATION SINGLE GANG OUTLET, STUB EMPTY CONDUIT 6" INTO ACCESSIBLE CEILING SPACE FOR CRT CABLES. CABLES F.B.O. UNLESS NOTED OTHERWISE. MECHANICAL EQUIPMENT TAG-SEE MECHANICAL EQUIPMENT SCHEDULE NON-FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWING FUSED DISCONNECT SWITCH, SIZE AND RATING AS NOTED ON DRAWINGS ELECTRICAL PANEL MOTOR CONNECTION SINGLE GANG TELEPHONE OUTLET, STUB "EMPTY CONDUIT 6" INTO ACCESSIBLE CEILING SPACE UNLESS NOTED OTHERWISE JUNCTION BOX WALL MOUNTED JUNCTION BOX CEILING MOUNTED DOUBLE DUPLEX RECEPTACLE, 120V, 20 AMP RATED 18" A.F.F. UNLESS OTHERWISE NOTED. MOUNTED IN COMMON JUNCTION BOX. DUPLEX RECEPTACLE, 120 VOLT, 20 AMPERE RATED. UNLESS NOTED OTHERWISE. HUBBELL OR LEVITON #5362-I. SUBSCRIPT: "GFI" - DENOTES GROUND FAULT INTERRUPTER TYPE RECEPTACLE "IG" - DENOTES ISOLATED GROUND TYPE RECEPTACLE HUBBELL OR LEVITON #IG-5362 INDICATES "GREEN" GROUND CONDUCTOR, SIZED AS NOTED ON DRAWINGS CONDUIT RUN ROUTED CONCEALED IN/BELOW CONCRETE SLAB OR BELOW GRADE. CONDUIT RUN ROUTED CONCEALED IN WALLS OR ABOVE CEILING IN FINISHED AREAS. CONDUIT EXPOSED IN UNFINISHED AREAS THERMAL OVERLOAD TOGGLE SWITCH WITH PROPERLY SIZED HEATER ELEMENTS, 48" A.F.F. UNLESS EQUIPMENT MOUNTED SINGLE POLE TOGGLE SWITCH, 20 AMPERE RATED, MOUNTED 48" A.F.F. UNLESS NOTED OTHERWISE. SUBSCRIPT: "a" - LOWER CASE LETTER INDICATES SWITCH CONTROL "3" - DENOTES THREE WAY TOGGLE SWITCH "2P"- DENOTES TWO POLE TOGGLE SWITCH "P"- DENOTES LIGHTED HANDLE TOGGLE SWITCH, LIGHT IN SWITCH SHALL LIGHT WHEN EQUIPMENT IS OPERATING "4" - DENOTES FOUR WAY TOGGLE SWITCH WEATHERPROOF RETURN DUCT UP THRU FLOOR/ ROOF MANUAL VOLUME DAMPER THERMOSTAT EQUIPMENT TAG GAS PIPING GAS COCK REDUCER SUPPLY DUCT UP THRU FLOOR/ ROOF UNDERCUT DOOR ROOFTOP UNIT OUTSIDE AIR INTAKE NECK MANUAL VOLUME DAMPER GRILLE FURNISHED BY OTHERS EXTERNAL STATIC PRESSURE EXHAUST FAN EACH DIFFUSER CUBIC FEET OF AIR PER MINUTECFM DIFF EA EF-# ESP FBO GR MVD NK OAI RTU-# U-CUT 1.ELECTRICAL CONTRACTOR SHALL REVIEW THE ARCHITECTURAL DRAWINGS TO VERIFY THE EXTENT OF THE DEMOLITION AND REMODELING WORK. ELECTRICAL CONTRACTOR SHALL SURVEY EXISTING SITE AND DETERMINE EXTENT OF NECESSARY REALLOCATIONS. REMOVALS AND REPAIRS TO EXISTING ELECTRICAL WORK REQUIRED TO AVOID CONFLICTS WITH NEW CONSTRUCTION TO MEET MINIMUM CITY AND STATE CODE REQUIREMENTS. ALL ELECTRICAL OUTLETS, FIXTURES RECEPTACLES, DEVICES, ETC. NOT BEING REUSED SHALL BE REMOVED AND OUTLETS ARE TO BE CAPPED ACCORDING TO NOTE #7: CONDUIT TO BE ABANDONED IN PLACE: AND ALL WIRING SHALL BE DISCONNECTED AT SOURCE AND REMOVED COMPLETELY. NO EXISTING JUNCTIONS OR CONDUIT COVERS SHALL BE BURIED IN NEW WALLS. ELECTRICAL CONTRACTOR TO RELOCATE SAME AS REQUIRED. A FIELD SURVEY VERIFICATION IS MANDATORY IN ORDER TO SUBMIT AN ELECTRICAL BID, FAILURE TO DO SO SHALL NOT RELIEVE THIS CONTRACTOR FROM PERFORMING THE WORK OF THIS CONTRACT. 2.EXISTING CONDUIT CAN BE REUSED PROVIDING IT IS CHECKED FOR CONTINUITY OF GROUND, BLOWN FREE OF DEBRIS, AND DOES NOT INTERFERE WITH NEW CONSTRUCTION. 3.ALL CUTTING AND PATCHING OF EXISTING PLASTER, DRYWALL, WOOD, CONCRETE ETC., FOR THE ELECTRICAL INSTALLATION IS BY THE ELECTRICAL CONTRACTOR. BEFORE ANY CUTTING, APPROVAL FROM THE ARCHITECT IS NECESSARY. CARE IS TO BE TAKEN AND ALL CUTS OR CORING ARE TO BE SQUARE - NO CHOPPING! 4.ALL EXISTING EQUIPMENT IS TO REMAIN OPERATIONAL DURING THE CONSTRUCTION PERIOD. ANY TEMPORARY WIRING OR REROUTING OF CIRCUITRY TO ACHIEVE THIS IS BY THE ELECTRICAL CONTRACTOR. SHUTDOWN OF EXISTING SERVICES SHALL ONLY BE PERMITTED UPON WRITTEN APPROVAL FROM THE OWNER AND THEN ONLY FOR THE DATE AND DURATION AGREED UPON. INCLUDE ALL PREMIUM TIME CHARGES IN THE BASE BID. 5.UNLESS INDICATED OTHERWISE, ALL LIGHTING FIXTURES, ELECTRICAL DEVICES AND ALL ITEMS OF THE EXISTING HVAC SYSTEM SHALL REMAIN UNLESS IN CONFLICT WITH REMODELING. 6.ALL LIGHTING FIXTURES REMOVED AND NOT REUSED SHALL BECOME THE PROPERTY OF THE OWNER. IF THE OWNER ELECTS NOT TO RETAIN FIXTURES, ELECTRICAL CONTRACTOR SHALL REMOVE FIXTURES FROM JOB SITE AND DISPOSE OF PROPERLY. 7.ELECTRICAL CONTRACTOR SHALL BLANK WITH PROPER FINISH PLATE IF FLUSH OUTLET EXISTS FOR ITEMS TO BE REMOVED. ANY INTERRUPTION OF CIRCUITING TO AREAS NOT BEING REMODELED SHALL BE INTERCEPTED AT A LOCATION THAT DOES NOT INTERFERE WITH NEW CONSTRUCTION. HOMERUN CIRCUITING FOR THESE INTERRUPTED CIRCUITS IS TO BE NEW WIRING. AFTER REMOVAL, ALL CONTINUITY IS TO BE CHECKED FOR ALL OUTLETS IN THE AREAS NOT BEING REMODELED TO INSURE PROPER FUNCTIONING. 8.ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR FOR REMOVAL OR RELOCATION OF EXISTING ELECTRICAL EQUIPMENT (FOR EXAMPLE: LIGHTING FIXTURES, RECEPTACLES, DEVICES, CONDUIT AND WIRING) THAT WILL BE ABANDONED OR IN CONFLICT WITH NEW CONSTRUCTION. NO ADDITIONAL COST WILL BE PERMITTED. REFER TO ARCHITECTURAL DRAWINGS FOR EXTENT OF REMODELING. 9.ALL CONDUIT, DEVICES, FIXTURES, ETC. SHOWN IN THE DEMOLITION DRAWINGS TO BE REMOVED OR RELOCATED ARE ONLY FOR THE CONVENIENCE OF THE BIDDERS. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL ITEMS PRIOR TO SUBMITTING A BID. 10.NEW WORK AND EQUIPMENT IN THE EXISTING BUILDING HAS BEEN INDICATED ON THE DRAWINGS AS ACCURATELY AS POSSIBLE. EACH CONTRACTOR SHALL ADJUST HIS WORK AS REQUIRED TO AVOID EXISTING DUCTS, PIPES, CONDUITS AND BEAM NOT SHOWN ON PLANS. EACH CONTRACTOR SHALL ADAPT HIS WORK TO MEET ALL ACTUAL CONDITIONS ON THE EXISTING PREMISES. 1.ALL EQUIPMENT/DEVICES SHALL BE NEW AND OF FIRST RATE QUALITY (UNLESS OTHERWISE SPECIFIED) AND IS TO BEAR THE APPROPRIATE AGA, CSA OR UL APPROVED LABELS, LISTINGS, AND CERTIFICATIONS FOR THE SPECIFIC DESIGN PURPOSE. 2.ALL EQUIPMENT SOUND LEVELS SHALL NOT EXCEED 50 DB AT PROPERTY LINE. 3.ALL INTERCONNECTING WIRING AT UNIT SHALL BE FACTORY PREWIRED AND REQUIRE ONLY ONE (1) POWER CONNECTION TO THE UNIT BY THE ELECTRICAL CONTRACTOR. DISCONNECT SWITCH SHALL BE BY THE ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. 4.ELECTRICAL CONTRACTOR SHALL FURNISH COMBINATION MAGNETIC STARTER-DISCONNECT SWITCHES AS REQUIRED (WEATHERPROOF FOR EQUIPMENT LOCATED OUTSIDE OF BUILDING). THE ELECTRICAL CONTRACTOR WILL INSTALL. 5.SUBMIT EIGHT (8) COPIES OF EACH CATALOG CUT, FOR THE EQUIPMENT SPECIFIED, TO THE ARCHITECT/ENGINEER FOR APPROVAL PRIOR TO THE BEGINNING OF CONSTRUCTION. THIS CONTRACTOR SHALL ALSO ASSEMBLE PRINTED INSTRUCTIONS FOR THE OPERATION AND MAINTENANCE OF EACH ITEM INSTALLED AND BIND TOGETHER WITH EQUIPMENT CUTS AND CONTROL WIRING DIAGRAMS. SUBMIT EIGHT (8) COPIES TO THE OWNER/ARCHITECT/ENGINEER. 6.THIS CONTRACTOR SHALL FURNISH AND INSTALL ALL NEW STRUCTURAL STEEL MEMBERS, SLEEVES, AND SHIMS REQUIRED TO LEVEL AND SUPPORT EQUIPMENT, ROOF CURBS AND EQUIPMENT SUPPORTS. DUCTWORK: 1.ALL DUCTWORK SHALL BE FABRICATED FROM GALVANIZED METAL IN ACCORDANCE WITH SMACNA STANDARDS FOR LOW AND MEDIUM PRESSURE DUCT CONSTRUCTION, DUCT SIZES SHOWN INDICATE INSIDE DIMENSIONS. 2. ALL DUCTWORK ACCESS DOORS SHALL BE OF SUFFICIENT SIZE TO PERMIT EASY ACCESS AND THE SERVICING OF DAMPERS, CONTROLS, DEVICES, ETC. ACCESS DOORS SHALL BE VENTLOK COMPLETE WITH #50 HINGES WITH BRASS PINS, #100 LATCHES, DOOR GASKETS, ETC. DOORS LOCATED IN INSULATED DUCTWORK SHALL HAVE 1/2" THICK FIBERGLASS INSULATION BETWEEN TWO THICKNESS OF SHEET METAL. 3.DUCTWORK SHALL COMPLY WITH ALL REGULATIONS REGARDING FIRE STOPPING, PROOFING AND DAMPERING. ACCESS DOORS OF SUFFICIENT SIZE FOR EASY ACCESS AND SERVICING SHALL BE PROVIDED AT ALL FIRE DAMPERS. 4.AIR VELOCITY IN LOW PRESSURE MAIN SUPPLY TRUNKS SHALL NOT EXCEED 1500 FPM, IN SUPPLY BRANCHES VELOCITY SHALL NOT EXCEED 1200 FPM, AND IN RETURN AIR DUCT VELOCITY SHALL NOT EXCEED 1200 FPM. DUCT INSULATION: 1.ALL SUPPLY DUCTWORK FROM HEATING/COOLING UNITS SHALL BE LINED WITH 1-1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER. DUCT LINING AND ADHESIVE SHALL BE IN CONFORMANCE WITH NFPA NO. 90A STANDARDS. 2.ALL RETURN DUCTWORK WITHIN 10'-0" OF HEATING/COOLING UNITS SHALL BE LINED WITH 1-1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER. DUCT LINING AND ADHESIVE SHALL BE IN CONFORMANCE WITH NFPA NO. 90A STANDARDS. 3.ALL EXHAUST DUCTWORK ON THE SUCTION SIDE OF EXHAUST FANS SHALL BE LINED WITH 1-1/2 LB DENSITY, 1/2" THICK FIBERGLASS DUCT LINER, FOR A MINIMUM DISTANCE OF 10'-0". 4.ALL DUCT INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED RATING OF NOT MORE THAN 50. 5.EXPOSED SPIRAL DUCT SHALL BE UN-INSULATED. PROVIDE INSULATION ONLY IF REQUIRED BY GOVERNING AGENCIES. DUCT SMOKE DETECTOR: 1.DUCT SMOKE DETECTORS SHALL BE INSTALLED IN SUPPLY AND RETURN DUCTS ON ALL A/C EQUIPMENT 2000 CFM OR LARGER. ELECTRICAL CONTRACTOR TO SUPPLY AND WIRE DETECTOR. MECHANICAL CONTRACTOR TO DUCT MOUNT DETECTOR. ELECTRICAL AND MECHANICAL CONTRACTORS TO COORDINATE SIZES AND TYPES FOR INSTALLATION. GAS PIPING: (IF APPLICABLE) 1.THIS CONTRACTOR SHALL CONTACT LOCAL GAS COMPANY TO COORDINATE: NEW GAS LOAD EXISTING, METER LOCATION, AND PRESSURE REGULATOR ASSEMBLY. 2.GAS PIPING SHALL BE SCHED. 40 BLACK CARBON STEEL, WITH MALLEABLE IRON 150 LB. FITTINGS. GAS PIPING LARGER THAN 2" SHALL BE WELDED, PIPING UNDER 2" SHALL BE THREADED CONNECTIONS - PAINT TO MATCH. 3.GAS COCKS (CRANE #254 WITH CHECK OR EQUAL), AND DIRT LEGS (MIN. 6") SHALL BE INSTALLED IN THE PIPING TO EACH PIECE OF GAS FIRED EQUIPMENT. 4.BEFORE FINAL EQUIPMENT CONNECTIONS ARE MADE, PNEUMATICALLY TEST GAS PIPING AT 15 PSIG AIR PRESSURE. THE PRESSURE TEST SHALL BE DEEMED ACCEPTABLE IF THE PIPING SYSTEM HOLDS THE PRESSURE FOR FOUR (4) HOURS. TESTING SHALL BE WITNESSED BY OWNER. E L E C T R I C A L S Y M B O L S L I S TP L U M B I N G M A T E R I A L & P R O C E D U R E N O T E S M E C H A N I C A L S Y M B O L S L I S TM E C H A N I C A L E Q U I P M E N T N O T E S E L E C T R I C A L S Y M B O L S N O T E S M E C H A N I C A L M A T E R I A L A N D P R O C E D U R E N O T E S E L E C T R I C A L D E M O L I T I O N N O T E S JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com ELECTRICAL: ALTERNATE MECHANICAL CONNECTIONS FOR THE REMOTE SPLIT SYSTEM COMPRESSOR FOR THE WALK-IN COOLERS CONTRACTOR TO CONFIRM TYPE OF WALK-IN COMPRESSOR CONFIGURATION WITH EQUIPMENT SUPPLIER AND FRANCHISEE. OPTIONS ARE REMOTE AND DIRECT MOUNTED. CONTACT Projects@kecdesign.com SHEET E-1 DISCONNECT SWITCH FOR SINGLE POINT CONNECTION TO CONDENSING UNIT. FUSE PER UNIT NAME PLATE. CONTRACTOR TO INSTALL CONTROL WIRING BETWEEN THE EVAPORATOR UNIT AND CONDENSING UNIT AND INSTALL DRAINLINE HEAT TAPE PER MANUFACTURERS RECOMMENDATIONS. WEATHER PROOF GFI DEDICATED FOR HEAT TRACE. SHEET E-3 1 2 ALTERNATE FREEZER/COOLER POWER PLAN 1/2" = 1'-0"A 3 PANEL SCHEDULE "JJ" E Q U I P M E N T P O W E R S C H E D U L E X 25 1908 27 20/2 1908 20/2 1452 1452 WALK-IN FREEZER CONDENSING UNIT WALK-IN FREEZER EVAPORATOR UNIT 33 29 109231 20/2 1092 20/1 1090 WALK-IN COOLER CONDENSING UNIT WALK-IN COOLER EVAPORATOR UNIT PLUMBING: 1 ALTERNATE FREEZER/COOLER PLUMBING PLAN 1/2" = 1'-0"B SHEET P-1 CONDENSATE LINES MUST STUB OUT DIRECTLY FROM WALK-INS 20" BELOW CEILING OF WALK-IN, CENTERED ON BACK PANEL OF EACH BOX. MUST NEVER HAVE EXPOSED LINES ON INSIDE OF WALK-INS. ROUTE 1" CONDENSATE LINES FROM COOLER/FREEZER EVAPORATORS IN CAVITY/FURR WALL TO MOP SINK OR FLOOR DRAIN AS SHOWN. MUST RUN 1/2" PER 1'-0" DROP. MUST STUB OUT AT 12" ABOVE MOP SINK OR FLOOR DRAIN AND TERMINATE WITH AIR GAP. HEAT TRACE CONDENSATE LINE INSIDE FREEZER. WRAP ARMAFLEX AROUND THE CONDENSATE LINES IN THE WALK-IN FREEZER AND INSULATE LINES IN THE COOLER.23 21 SHEET A-4 ADD NOTE STATING: RUSSELL WALK-IN FREEZER/COOLER WITH REMOTE MOUNTED COMPRESSORS UNIT. COMPRESSOR SHALL BE MOUNTED ON THE ROOF ON ONE BASE. CONTRACTOR SHALL VERIFY EXACT REQUIREMENTS WITH JIMMY JOHN'S EQUIPMENT SUPPLIER. ARCHITECTURAL: F I X T U R E A N D E Q U I P M E N T S C H E D U L E 1 1 WALK-IN FREEZER WALK-IN COOLER 208V-1P-WIRE TO J-BOX 120V-1P-1WIRE TO J-BOX MECHANICAL: SHEET M-1 NEW ROOF MOUNTED REMOTE CONDENSING UNIT PROVIDED BY OWNER, INSTALLED BY REFRIGERATION CONTRACTOR. ROUTE LIQUID/SUCTION REFRIGERANT LINES THRU ROOF TO COOLER/FREEZER EVAPORATORS. 1 ALTERNATE FREEZER/COOLER MECHANICAL PLAN 1/2" = 1'-0"C 23A 23 WALK-IN FREEZER COMPRESSOR WALK-IN COOLER COMPRESSOR FD 1SQ TP A-21,23 A-25,27 A-29,31 A-35 A-33 TP A-35 JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com MEP-3 SPECIFICATIONS ALT. WALK-INS PROVIDE LOCAL DISCONNECT FOR EVAPORATORWALK-IN FREEZER LIGHTS (2), DOOR HTR.2.3A 2 #12, 3/4"C J-BOX VERIFY 1P, 20A120V/1 Ø23B WALK-IN FREEZER CONDENSING UNIT WALK-IN FREEZER EVAPORATOR UNIT 15.9A 25A/2P DISCONNECT 2P, 25A 20A/1P DISCONNECT 12.1A VERIFY 1P, 20A INTERLOCK WITH FREEZER CONDENSER240V/1 Ø 240V/1 Ø 3 #12, 1 #12, GRD., 3/4" C.ON ROOF INTERLOCK WITH FREEZER EVAPORATOR 2 #12, 1 #12 GRD., 3/4"C.23 23 9.1A 15A/2P DISCONNECT 2P, 15A 20A/1P DISCONNECT -VERIFY 1P, 20A120V/1 Ø 240V/1 Ø 3 #12, 1 #12, GRD., 3/4" C.ON ROOF 2 #12, 1"C.23A 23A INTERLOCK WITH COOLER CONDENSER INTERLOCK WITH COOLER EVAPORATORWALK-IN COOLER CONDENSING UNIT WALK-INCOOLER EVAPORATOR UNIT 27,29 23,25 31,33 35 37 A A A A A (FLA)BREAKER REMARKSWIRE & CONNECTION TYPE OF NO. CIRCUITLOAD PANEL FROM CONDUITDESCRIPTIONTAG PHASE VOLTAGE MOUNTING HEIGHT FE FE FE ALL RECEPTACLES IN THE FOOD PREP AREA ARE TO BE GFI AND INSTALLED IN ACCESSIBLE LOCATION OR CONTRACTOR IS TO PROVIDE GFI BREAKER AS REQUIRED. +42" TP MOUNT IN CABINET A-18 GFI GFI GFI GFI GFI A-11 I.G. B-15 A-2 A-4 A-26 GFI B-1 B-5 B-13 B-19 A-5 +12" GFI +29" A-9 +12" A-30 2 #12, 3/4"C WP J GFI +72" GFI A-10 A-21,23 A-25,27 A-29,31 A-34 A-36 A-24 A-22 A-14 A-12 A-8(d) A-1 A-3 A-7 A-32 A-35 A-33 A-16 2 #12, 3/4"C WPJ PANEL "A" 200A 120/208V PANEL "B" 200A 120/208V TP 6'-6" 1' - 8 " +12" +12" A-15,17,19 50/3PH A-8(d) A-35 B-16,18 B-20,22 MOUNT IN CABINET FE A-37 A-39 A-41 GFI B-11 B-4 B-21 B-23 B-25 T (RTU-2) T (RTU-1) A-13 B-3 B-28 B-30 B-32 EXISTING EXISTING FE B-37,39,41 A-38,40,42 RTU 1 RTU 2 WP J A-20 JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com E-1 POWER PLAN ELECTRICAL K E Y E D N O T E S ELECTRICAL POWER PLAN 1/4" = 1'-0"A NORTH ELECTRICAL SCHEDULE REF SHEET E-1.1 DIGITAL MENU BOARD DETAIL N.T.S.D MOUNT THE NETWORK CABINET (OR APPROVED EQUIVALENT) ON THE WALL BELOW AND TIGHT TO THE DROP CEILING NEAR DESK SHELVES - PROVIDE DUPLEX RECEPTACLE AND DSL LINE IN THE NETWORK CABINET, SEE COM1 FOR MORE INFORMATION. DRIVERS BOX OUTLETS - SEE 1/COM-1 FOR MOUNTING HEIGHTS AND LOCATIONS. PROVIDE ONE (1) 3/4" CONDUIT STUBBED UP INTO ACCESSIBLE CEILING. VERIFY LOCATION IN FIELD FOR ALL VOICE AND DATA LOCATIONS . STUB POWER FROM WALL AT 18" AFF IN SEAL TIGHT ELECTRICAL WHIP CONNECTED TO OVEN. INSTALL LOCK OUT BREAKER ON CIRCUIT AT PANEL. EXISTING ELECTRICAL PANEL - FULLY RECESSED- PANEL DOORS TO BE FLUSH MOUNTED OVER FINISHED SURFACE. STORE FRONT SIGN CONTROLLED BY TIME SWITCH LOCATED NEAR NETWORK CAB'T, TIGHT TO THE CEILING. ELECTRICAL CONTRACTOR TO VERIFY LOCATION OF SIGN JUNCTION BOX WITH SIGN VENDOR AND ARCHITECT. PROGRAMMABLE THERMOSTAT (AT 48" AFF MAX.) FOR RTU WITH CLEAR LOCK BOX - COORDINATE RECESSED "J" BOX WITH ALL FINISH WALL MATERIALS/DEVICES. DUPLEX OUTLET TO ALIGN VERTICALLY WITH DATA OUTLET BELOW - SEE DETAIL-4/COM-1. DRIVE THRU TIMER - SEE ELECTRICAL/DATA DETAIL-4/COM-1. DUPLEX OUTLET AT +63.5" TO ALIGN VERTICALLY WITH DATA OUTLET BELOW. BOTH ELECTRICAL AND DATA BOXES MUST BE PLACED 10" FROM CENTER LINE OF THE DEPTH OF THE CABINET OPPOSITE THE DRIVE THRU WINDOW SIDE. COMMUNICATION PANEL (HME) FOR DRIVE THRU SERVICE TO BE MOUNTED BEHIND WING WALL - SEE DETAIL-3/COM-1. 3/4" CONDUIT TO THE ELECTRICAL PANEL FOR DRIVE THRU MENU POWER. TRENCH UNDERGROUND AS REQUIRED TO INSIDE OF BUILDING. BRING UP IN FURRED WALL. MAGNETIC LOOP TO TIE INTO TIMER AT DRIVE THRU WINDOW - SEE DETAIL- 4/COM-1FOR TIMER DETAIL. REFERENCE COM-1 FOR DETAIL. DUPLEX OUTLET TO BE INSTALLED AT 12" AFF FOR CO2 SENSOR POWER, ALL WIRES FROM THE SENSOR TO THE ALARM (INSTALLED TIGHT TO THE BOTTOM OF THE CEILING ABOVE) ARE TO BE RECESSED IN THE WALL. FLUSH MOUNTED RECEPTACLE CENTERED ABOVE EVERY WINDOW AND DOOR TRANSOM FOR NEON SIGNS, RECEPTACLE TO BE INSTALLED BETWEEN THE UPPER AND LOWER WINDOW. NEW ELECTRICAL PANEL - FULLY RECESSED- PANEL DOORS TO BE FLUSH MOUNTED OVER FINISHED SURFACE. 13 12 11 10 8 7 6 5 4 3 2 1 9 14 15 HVAC POWER PLAN 1/4" = 1'-0"C DRIVE THRU POWER PLAN 1/4" = 1'-0"B NORTH DRIVE THRU: MENU BOARD CAN BE FOUND BACK OF BUILDING APPROXIMATELY 100' FEET SOUTH FROM MAIN ENTRANCE E-1.1 SCHEDULE ELECTRICAL JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com E.C TO FIELD VERIFY BUILDING ELECTRICAL SERVICE (VOLTS,PHASE,AMPS) PRIOR TO BID. IF THERE IS ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND FIELD CONDITIONS, E.C. IS TO NOTIFY FRANCHISEE, ARCHITECT AND ENGINEER IMMEDIATELY. ELECTRICAL NOTE: ELECTRICAL CONTRACTOR TO COORDINATE ALL CONDUIT LOCATIONS WITH THE COMMUNICATIONS/DATA SUL-CONTRACTOR. GENERAL REQUIREMENTS A. E.C. SHALL COORDINATE FULLY WITH OTHER CONTRACTORS ASSOCIATED WITH THIS PROJECT TO VERIFY ALL EQUIPMENT LOCATIONS, CONNECTION REQUIREMENTS, ELEVATIONS AND LOCATIONS OF PIPES, CONDUITS AND DUCTS TO PREVENT CONFLICTS DURING CONSTRUCTION. ANY RELOCATION OR REROUTING OF EQUIPMENT, PIPES, CONDUITS, DUCTS OR MATERIALS RESULTING FROM A LACK OF COORDINATION BETWEEN CONTRACTORS WILL BE AT THE CONTRACTORS EXPENSE. B. EQUIPMENT ROUGH-INS SHOWN ARE ACCURATE TO THE BEST OF DESIGNER'S KNOWLEDGE. HOWEVER, IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN. THEREFORE,THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE E.C. TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR. C. E.C. SHALL FURNISH AND INSTALL ALL REQUIRED DISCONNECT SWITCHES AND MOTOR STARTERS TO ALL EQUIPMENT. D. E.C. SHALL REVIEW WITH OWNER AND SIGNAGE MANUFACTURER, REQUIREMENTS AND LOCATION OF BUILDING SIGNAGE PRIOR TO CONSTRUCTION AND PROVIDE 120VAC CONNECTION AS REQUIRED. E. E.C. SHALL PROVIDE AS-BUILT DRAWINGS AT JOB COMPLETION TO ARCHITECT. F. ALL WORK SHALL BE INSTALLED PER ALL GOVERNING CODES. G. SUBCONTRACTOR IS TO SUPPLY AND INSTALL ALL BLOCKING REQUIRED TO HANG/MOUNT LIGHTS INCLUDING RESTROOM FIXTURES. BLOCKING IS TO BE FIRE RATED IF REQUIRED BY LOCAL CODES. H. SUBCONTRACTOR IS TO SUPPLY AND INSTALL UNISTRUT AND 3/8" THREADED ROD TO HANG/SUPPORT LIGHTING. RACEWAY SYSTEMS A. ALL BRANCH CIRCUIT WIRING SHALL BE ROUTED IN EMT, RIGID OR ELECTRICAL METALLIC TUBING. USE STEEL SET SCREW TYPE FITTINGS ON ALL EMT. B. CONDUIT SHALL BE SUPPORTED AT INTERVALS PER NEC REQUIREMENTS AND SHALL BE SECURELY FASTENED TO BUILDING WITH AN APPROVED FASTENING SYSTEM. C. ALL NEW CONDUIT TO BE CONCEALED IN WALLS. PATCH/PAINT IF NECESSARY. WIRING, WIRING DEVICES, PLATES AND GROUNDING A. ALL WIRING SHALL CONSIST OF COPPER CONDUCTORS WITH THERMOPLASTIC INSULATION RATED FOR SIX HUNDRED (600) VOLTS. ALL WIRING INSULATION SHALL BE HEAT AND MOISTURE RESISTANT TYPES THW, THWN, OR THHN FOR INTERNAL AND DRIVE LOCATIONS. B. MINIMUM CONDUCTOR SIZE SHALL BE NO. 12 AWG FOR ALL BRANCH CIRCUITS (I.E. RECEPTACLES, LIGHTING, EQUIPMENT POWER, ETC.). MINIMUM CONDUCTOR SIZE SHALL BE NO. 10 AWG FOR ALL FEEDER CIRCUITS TO MECHANICAL EQUIPMENT (I.E U-1, CONDENSERS, ETC.) C. ALL SPLICED OR CONNECTIONS SHALL BE MADE IN OUTLET BOXES, JUNCTION BOXES OR EQUIPMENT WHERE ACCESSIBLE. D. CONDUCTORS SHALL BE PULLED WITHOUT THE USE OF OIL OR GREASE. WIRE PULLING LUBRICANTS WHICH ARE APPROVED FOR USE WITH CONDUCTOR INSULATION MAY BE USED. CARE SHALL BE TAKEN IN PULLING WIRE TO ASSURE THAT MAXIMUM ALLOWABLE PULLING TENSION OF WIRE IS NOT EXCEEDED. WIRING WITH DAMAGED CONDUCTORS OR INSULATION WILL NOT BE ACCEPTED. E. ALL PLUG-IN DEVICES SHALL BE GROUNDED TYPE. A GROUNDING JUMPER FROM RECEPTACLE TO OUTLET BOX SHALL BE INSTALLED WHERE CONDUIT SYSTEM IS USED FOR GROUND. F. INSTALL INSULATED GREEN GROUNDING CONDUCTOR (NO. 12 AWG MINIMUM) IN RACEWAYS AS INDICATED ON DRAWINGS AND IN ALL NON-METALLIC RACEWAYS PER NEC. G. SWITCHES FOR LIGHTING CONTROL SHALL BE INDUSTRIAL GRADE. DEVICES AND PLATES TO MATCH WALLS IN THE DINING ROOM, WHITE DEVICES WITH STAINLESS PLATES IN THE KITCHEN AND RESTROOMS. SIDE WIRED ONLY, TWENTY (20) AMP, ONE HUNDRED TWENTY/TWO HUNDRED SEVENTY-SEVEN (120/277) VOLT. H. DUPLEX RECEPTACLES SHALL BE INDUSTRIAL GRADE, THREE (3) WIRE GROUNDING, WHITE COLOR, FINDER GROOVE, TWENTY (20) AMP, NEMA 5-20R 125 VAC. DEVICES AND PLATES TO MATCH WALLS IN THE DINING ROOM, WHITE DEVICES WITH STAINLESS STEEL PLATES IN THE KITCHEN AND RESTROOMS. I. PLATES SHALL BE FURNISHED AND INSTALLED FOR ALL WIRING DEVICES, TELEPHONE OUTLETS, JUNCTION BOXES, ETC. J. PLATES FOR FLUSH MOUNTED DEVICES SHALL MATCH THE SURROUNDING FINISH, EXCEPT IN THE KITCHEN/PREP AREA AND RESTROOMS WHERE THEY SHALL BE STAINLESS STEEL SURFACE MOUNTED BOXES SHALL BE GALVANIZED STEEL. K. E.C. SHALL BE RESPONSIBLE FOR PROPERLY BALANCING ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM; REGARDLESS OF CIRCUITING INDICATED. L. ALL DUPLEX RECEPTACLES INSTALLED IN KITCHEN AND PREPERATION AREA ARE TO BE GFCI RATED, WHERE NOT PROTECTED BY A GFCI CIRCUIT BREAKER. M. THERE WILL BE NO MC RUNNING HORIZONTALLY OVER 12" IN LENGTH IN ANY EXPOSED AREA OR AREAS VISBILE TO THE CUSTOMER. ANY HORIZONTAL CONDUIT MUST BE LEVEL. G E N E R A L R E Q U I R E M E N T S DRIVE-THRU DIRECTIONAL SIGN NOTE: RUN POWER FOR DRIVE-THRU DIRECTIONAL SIGNAGE. EXACT LOCATIONS TBD - COORDINATE WITH EXTERIOR SIGNAGE VENDOR. DRIVE-THRU WINDOW NOTE: IF AN AUTOMATIC DRIVE - THRU WINDOW IS CHOSEN THEN POWER WILL NEED TO BE RAN TO IT. CONSULT THE DRIVE- THRU WINDOW INSTALL GUIDE FOR ELECTRICAL REQUIREMENTS. OVEN DISCONNECT: ELECTRICIAN TO CONFIRM LOCK OFF DEVICE AT PANEL IS SUFFICIENT. IF DISCONNECT IS REQUIRED CONTACT JJ CONSTRUCTION FOR INSTALL INSTRUCTIONS. E.C. SHALL F & I T.T. SWITCH AT UNIT AND WIRE COMPLETE. FAN INTERLOCKED THRU LOCAL LIGHT SWITCH 0.8 FLA KW/HP/FLA/MCA REMARKSVOLTAGE/ PHASE 115/1 ØEXHAUST FAN DESCRIPTIONTAG EF-1 M E C H A N I C A L E Q U I P M E N T P O W E R S C H E D U L E 1.ELECTRICAL CONTRACTOR SHALL REFER TO ALL MECHANICAL, PLUMBING AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT LISTED BELOW. ANY MODIFICATION AND/OR ADDITIONAL WORK NECESSARY SHALL BE INCLUDED IN THE BASE BID. 2.ELECTRICAL CONTRACTOR SHALL CHECK THE ROTATION OF ALL THREE PHASE MOTORS AND CORRECT THE ROTATION IF REVERSED. 3.ALL TEMPERATURE CONTROL AND INTERLOCK WIRING SHALL BE BY HVAC CONTRACTOR UNLESS NOTED OTHERWISE. 4.ELECTRICAL CONTRACTOR SHALL SUBMIT EIGHT (8) SETS OF CATALOG CUTS FOR ALL SCHEDULED EQUIPMENT FURNISHED BY THIS CONTRACTOR FOR ARCHITECT/ENGINEER REVIEW. 5.ELECTRICAL CONTRACTOR SHALL COORDINATE THE ROUTING OF POWER WIRING TO ROOF-MOUNTED EQUIPMENT WITH MECHANICAL PIPE CURB ASSEMBLY. NO SEPARATE ROOF PENETRATIONS WILL BE PERMITTED. 6.ELECTRICAL CONTRACTOR SHALL FURNISH AND WIRE DUCT SMOKE DETECTORS IN THE RETURN AIR PLENUM AND A FAN SHUT DOWN RELAY FOR ALL AIR SUPPLY UNITS. DETECTORS TO BE INSTALLED BY MECH. CONTR. 7.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL A WEATHER PROOF, GROUND FAULT INTERRUPTER TYPE RECEPTACLE, AT AN ACCESSIBLE LOCATION FOR SERVICING ON ROOFTOP HEATING AND AIR CONDITIONING EQUIPMENT. THIS RECEPTACLE SHALL BE LOCATED WITHIN 25 FEET AND AT THE SAME LEVEL OF THIS EQUIPMENT. M E C H A N I C A L E Q U I P M E N T P O W E R S C H E D U L E N O T E S RTU-1 ROOF TOP UNIT (EXISTING) WH-1,2 NATURAL GAS WATER HEATER EXISTING (EXISTING) REF. PLUMBING SHEETS REF. MECH SHEETS29 MCA (FLA)BREAKER REMARKSWIRE & CONNECTION TYPE OF NO. CIRCUITLOAD PANEL FROM CONDUITDESCRIPTIONTAG E Q U I P M E N T P O W E R S C H E D U L E PHASE VOLTAGE MOUNTING HEIGHT 1.ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATION, HEIGHT AND ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT PRIOR TO ROUGH-IN WITH KITCHEN EQUIPMENT SUPPLIER, AND KITCHEN ROUGH-IN DRAWINGS. 2.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED LOCAL DISCONNECTS AND SPECIAL ENCLOSURES (I.E., NEMA 3R, STAINLESS STEEL, ETC.) PER LOCAL CODE. 3.ELECTRICAL CONTRACTOR SHALL CHECK ROTATION OF ALL THREE PHASE MOTORS AND CORRECT ROTATION IF REVERSED. 4.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL CIRCUIT BREAKER LOCK-ON DEVICES FOR ALL BRANCH CIRCUITS SERVING REFRIGERATION EQUIPMENT. 5.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL FINAL EQUIPMENT POWER AND CONTROL TERMINATIONS. 6.ELECTRICAL COMPONENTS FURNISHED LOOSE BY KITCHEN EQUIPMENT SUPPLIER (OR BY THE ELECTRICAL CONTRACTOR AS NOTED) SHALL BE MOUNTED AND WIRED BY THE ELECTRICAL CONTRACTOR. 7.ALL FLEXIBLE CONDUIT EQUIPMENT CONNECTIONS SHALL BE: "SEAL TIGHT". WARMER WAFFLE CONE BAKER KIT 120V/1 Ø 120V/1 Ø 4.2A 10A B 1 2 #12, 3/4"C IN CASEWORK IN CASEWORK 1P, 20A 1P, 20A 1P, 20AUNDERCOUNTER REFRIGERATOR 2.2A SINGLE DIPPING CHOCOLATE WARMER 120V/1 Ø IN CASEWORK0.8A 1P, 20A BASKIN-ROBBINS GFCI RECEPTACLE 2 #12, 3/4"C GFCI RECEPTACLE 2 #12, 3/4"C GFCI RECEPTACLE 2 #12, 3/4"C GFCI RECEPTACLE115V/1 Ø B B B DIPPING CABINET (2)120V/1 Ø 8.5A B IN CASEWORK 1P, 20A GFCI RECEPTACLE2 #12, 3/4"C HARDENING CABINET 120V/1 Ø 12.5A B STAND MIXER 120V/1 Ø 2.2A B 2 #12, 3/4"C 2 #12, 3/4"C GFCI RECEPTACLE GFCI RECEPTACLE 13 & 21 19 25 3 5 4 (FLA)BREAKER REMARKSWIRE & CONNECTION TYPE OF NO. CIRCUITLOAD PANEL FROM CONDUITDESCRIPTIONTAG E Q U I P M E N T P O W E R S C H E D U L E PHASE VOLTAGE MOUNTING HEIGHT 1.ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATION, HEIGHT AND ELECTRICAL CHARACTERISTICS OF ALL EQUIPMENT PRIOR TO ROUGH-IN WITH KITCHEN EQUIPMENT SUPPLIER, AND KITCHEN ROUGH-IN DRAWINGS. 2.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED LOCAL DISCONNECTS AND SPECIAL ENCLOSURES (I.E., NEMA 3R, STAINLESS STEEL, ETC.) PER LOCAL CODE. 3.ELECTRICAL CONTRACTOR SHALL CHECK ROTATION OF ALL THREE PHASE MOTORS AND CORRECT ROTATION IF REVERSED. 4.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL CIRCUIT BREAKER LOCK-ON DEVICES FOR ALL BRANCH CIRCUITS SERVING REFRIGERATION EQUIPMENT. 5.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL FINAL EQUIPMENT POWER AND CONTROL TERMINATIONS. 6.ELECTRICAL COMPONENTS FURNISHED LOOSE BY KITCHEN EQUIPMENT SUPPLIER (OR BY THE ELECTRICAL CONTRACTOR AS NOTED) SHALL BE MOUNTED AND WIRED BY THE ELECTRICAL CONTRACTOR. 7.ALL FLEXIBLE CONDUIT EQUIPMENT CONNECTIONS SHALL BE: "SEAL TIGHT". P.O.S. SYSTEM ICE/DRINK DISPENSER REFRIGERATED PREP TABLE (2) SLICER 120V/1 Ø 120V/1 Ø 4.1A 4A/4A 13.29A 2 #12, 3/4"C 2 #12, 3/4"C 2 #12, 3/4"C 1 #12 GRD QUAD I.G. RECEPTACLE DUPLEX RECEPTACLE DUPLEX RECEPTACLE 12" A.F.F. IN CASEWORK IN CASEWORK 1P, 20A 1P, 20A 1P, 20A GFCI BREAKER LOCATE RECEPTACLE WITHIN CASEWORK 120V/1 Ø 6.0A 2 #12, 3/4"C120V/1 Ø 1P, 20AGFCI RECEPTACLE2 #12, 3/4"C115V/1 ØREACH-IN REFRIGIRATOR 5A 72" A.F.F. PROVIDE LOCAL DISCONNECT FOR EVAPORATORWALK-IN FREEZER LIGHTS (2), DOOR HTR.2.3A 2 #12, 3/4"C J-BOX VERIFY 1P, 20A120V/1 Ø 5-15 RECEPTACLE LOCATE RECEPTACLE WITHIN CASEWORK IN CASEWORK 1P, 20AGFCI RECEPTACLE120V/1 ØTEA BREWER 15A LOCATE IN CASEWORK DUPLEX RECEPTACLE 2 #12, 1 #12 GRD., 3/4"C. 1P, 20AGFCI RECEPTACLE2 #12, 3/4"C120V/1 ØICE/DRINK DISPENSER 4A/4A DRIVE THRU P.O.S. SYSTEM 120V/1 Ø 4.1A 2 #12, 3/4"C 1 #12 GRD DUPLEX I.G. RECEPTACLE 28" AFF 1P, 20A LOCATE FLUSH MOUNTED RECEPTACLE WITHIN WALL12" AFF 2 #12, 3/4"C GFCI RECEPTACLE 81" AFF CENTERED ABOVE BAG N BOX1P, 20A120V/1 ØCARBONATOR 7A X 16D 3 8A 49 22 27 13 8 3 23B WALK-IN FREEZER CONDENSING UNIT WALK-IN FREEZER EVAPORATOR UNIT 15.9A 25A/2P DISCONNECT 2P, 25A 20A/1P DISCONNECT 12.1A VERIFY 1P, 20A INTERLOCK WITH FREEZER CONDENSER240V/1 Ø 240V/1 Ø 3 #12, 1 #12, GRD., 3/4" C.ON ROOF INTERLOCK WITH FREEZER EVAPORATOR 2 #12, 1 #12 GRD., 3/4"C.23 23 9.1A 15A/2P DISCONNECT 2P, 15A 20A/1P DISCONNECT -VERIFY 1P, 20A120V/1 Ø 240V/1 Ø 3 #12, 1 #12, GRD., 3/4" C.ON ROOF 2 #12, 1"C.23A 23A INTERLOCK WITH COOLER CONDENSER INTERLOCK WITH COOLER EVAPORATORWALK-IN COOLER CONDENSING UNIT WALK-INCOOLER EVAPORATOR UNIT 1P, 20A AIR MERCHANDISER 115V/1 Ø GFCI RECEPTACLE IN CASEWORK LOCATE IN CASEWORK15A2 #12, 3/4"C 1P, 20A9 OVEN/PROOFER 240V/1 Ø 53A 3 #4, 1 #8, GRD., 1" C. 70A/1P DISCONNECT 18" AFF 1P, 70A (3) WIRES PLUS A GROUND15A 1P, 20A 1P, 20A IN CASEWORK IN CASEWORK IN CASEWORK A A A A A A A A A A A A A A A B 11 1 12,14 2,4 13 5&9 15,17,19 22 10 26 15 JIMMY JOHN'S 71 16.7A208V/1 ØHIGH SPEED OVEN (2)2P, 30A3 #10, 1 #10, GRD., 3/4" C.+44" A.F.F.SPECIAL RECEPTACLE GFCI BREAKERB16,18 20,22 25,27 21,23 29,31 33 35 115/1 Ø 4.0A RTU-2 ROOF TOP UNIT 208/3 Ø 31 MCA VERIFY GFCI BREAKER 208/3 Ø 1P, 20ASAND WHICH / SALAD UNIT 3.3A 2 #12, 3/4"C GFCI RECEPTACLE115V/1 Ø IN CASEWORKB28 1P, 20ATWO GLASS DOOR MERCHANDISER 9.8A 2 #12, 3/4"C GFCI RECEPTACLE115V/1 Ø IN CASEWORKB35 107A 7AICE MACHINE GFCI BREAKERB32115V/1 Ø 2 #12, 3/4"C DUPLEX RECEPTACLE VERIFY 1P, 20A FE FE FE a b c d (9)(3) (3) (9)(9) B-24(c) B-24 B-26B-26 B-17(b) B-24(c) B-24(c) B-24(c)B-24(c) B-17(b) B-17(b)B-17(b)B-17(b)B-17(b) B-17(b) B-17(b)B-17(b) B-17(a)B-17(a) B-17(a) B-17(a) B-17(a) B-17(a) B-17 B-17(a) B-17 B-24 B-24 B-24 B-24 B-24 B-24 NOTE: ALL COVER PLATES IN PREP AREA/ BACKROOM AND RESTROOMS ARE STAINLESS STEEL WITH WHITE DEVICES. IN DINING AREA DEVICES AND COVER PLATES ARE TO MATCH COLOR OF SURROUNDING SURFACES. 48 " PR E P A R E A - C K T # B - 1 7 ( b ) BA C K R O O M - C K T # B - 1 7 ( a ) DI N I N G A R E A - C K T # A - 8 ( d ) DI N I N G A R E A - C K T # B - 2 4 ( c ) 10 ' - 6 " K1 K ELECTRICIAN TO CONFIRM THAT FLOOD FIXTURES SHINE DOWNWARD OR ON WALLS UNOBSTRUCTED BY ANY STRUCTURAL OR MECHANICAL COMPONENTS. GC TO CONTACT JJ'S CONSTRUCTION DEPT. FOR DIRECTION ON HOW TO PROCEED IF LIGHTING WILL BE OBSTRUCTED. ELECTRICAL LIGHTING PLAN 1/4" = 1'-0"A F I X T U R E S C H E D U L E N O T E S E.C TO FIELD VERIFY BUILDING ELECTRICAL SERVICE (VOLTS,PHASE,AMPS) PRIOR TO BID. IF THERE IS ANY DISCREPANCIES BETWEEN THE CONTRACT DOCUMENTS AND FIELD CONDITIONS, E.C. IS TO NOTIFY FRANCHISEE, ARCHITECT AND ENGINEER IMMEDIATELY. ELECTRICAL NOTE: ELECTRICAL CONTRACTOR TO COORDINATE ALL CONDUIT LOCATIONS WITH THE COMMUNICATIONS/DATA SUB-CONTRACTOR. R E F L. C E I L I N G N O T E S 1. REFER TO MECHANICAL FOR EXACT NUMBER, TYPE AND LOCATION OF SUPPLY, RETURN AND EXHAUST FIXTURES. 2. REFER TO ELECTRICAL FOR EXACT NUMBER, TYPE AND LOCATION OF OUTLETS. 3. G.C. WILL COORDINATE THE WORK OF ALL TRADES INVOLVED IN THE CEILING WORK TO INSURE CLEARANCES FOR FIXTURES, DUCTS, PIPING, CEILING SUSPENSION SYSTEMS, ETC., NECESSARY TO MAINTAIN THE FINISHED CEILING HEIGHTS INDICATED ON ARCHITECTURAL DRAWINGS. 4. PERIMETER CEILING ANGLE, WHERE OCCURS, SHALL BE INSTALLED TIGHT TO PARTITION SURFACES, FREE FROM CURVES, BREAKS OR OTHER IRREGULARITIES BY G.C. 5. PROVIDE CEILING ACCESS AS REQUIRED FOR EQUIPMENT AND SYSTEM MAINTENANCE VERIFY MANUFACTURER RECOMMENDATIONS. 6. ALL SWITCHES AND DIMMERS SHALL BE LOCATED 48" ABOVE FINISHED FLOOR, TO CENTER OF SWITCHES AND 6" FROM DOOR FRAME U.O.N. MULTIPLE SWITCHES AT ONE LOCATION SHALL BE GAINED TOGETHER AND FINISHED WITH ONE COVER PLATE. 7. ALL SPECIFIC INFORMATION CONCERNING INSTALLATION OF VARIOUS ABOVE CEILING ELEMENTS ARE TO BE FOUND IN THE HVAC, PLUMBING, FIRE PROTECTION, ELECTRICAL AND LIGHTING DRAWINGS. 8. CONTRACTOR TO NOTIFY ARCHITECT OF ANY CONFLICT OF LIGHT FIXTURE LOCATIONS WITH MAIN RUNNERS, DUCTS, ETC., PRIOR TO INSTALLATION. 9. FURNISH AND INSTALL UNDERWRITERS LABORATORY, INC (UL) LABELED DEVICES THROUGHOUT. 10. G.C. TO INSURE THAT EXIT SIGNS & EMERGENCY LIGHTING TO MEET ADA/TITLE 24 REQUIREMENTS. L I G H T I N G F I X T U R E S C H E D U L EL I G H T I N G F I X T U R E S C H E D U L E DESCRIPTIONFIXTURE TYPE TYPE LAMPMANUFACTURER'S KEC STOCK/ITEM #CAT. NO.VOLTAGE BALLAST TYPE MOUNTINGLENSMOUNTINGHEIGHT REMARKS NOTES: NO SUBSTITUTIONS ON ANY FIXTURES.1. ALL LIGHT FIXTURES, LAMPS AND CEILING FANS ARE SUPPLIED BY OWNER AND INSTALLED BY ELECTRICAL CONTRACTOR. CONTACT KEC DESIGN, 301 MERCURY DRIVE, CHAMPAIGN, IL. 61822. PH: (217) 356-1640. W/RED LETTERS CLEAR ACRYLIC UNIVERSALSURFACE CLEAR ACRYLIC W/RED LETTERS I-2 I-3 H K1 CIRCUIT TRACK LIGHTOLIER: 600*NBK *CONTRACTOR TO VERIFY LENGTHS PRIOR TO ORDERING 1- CIRCUIT LINE VOLTAGE TRACK (11'-6" ) ---- -- -- -- ------ -- -- -- -- UNIVERSAL UNIVERSAL SURFACE SURFACE CIRCUIT TRACK MOUNT HEIGHT - ( 11'-6" ) INTERMATIC-T101 ------SURFACE 365 DAYS PROGRAMMABLE----LIGHTING TIME CLOCK KSTCO - 1581A 2'X4' LED FLAT PANEL LAY-IN DIMMABLE NUVO 65-324 A1 2'X2' LED FLAT PANEL LAY-IN- DIMMABLE KSTCO-1541 120 --CEILINGPMMARECESSED KSTCO-1582A-E 2'X4' LED EMERGENCY FLAT PANEL - DIMMABLE NUVO 65-348 120 --PMMA RECESSED 120 --PMMA RECESSED COORDINATE EMERGENCY FIXTURES TO BE NIGHT LIGHTS (KEEP ON SEPARATE CIRCUIT FROM TYP. PREP LIGHTS) CEILING CEILING 50W LED NUVO 65-321 40W LED 1.EXHAUST FAN IN RESTROOM TO BE LIGHT ACTIVATED. 2.ALL ACRYLIC LENS SHALL BE 100% VIRGIN ACRYLIC. 3.ALL FLUORESCENT LAMPS SHALL BE ENERGY SAVING TRIM LINE T8 WARM WHITE F32T8/SP35/RS 4.ALL BALLASTS SHALL BE RAPID START ELECTRONIC ENERGY SAVING TYPE. 5.ALL EXIT SIGNS AND EMERGENCY LIGHT FIXTURES ARE TO BE STRICT ACCORDANCE WITH THE LOCAL FIRE PREVENTION CODE AUTHORITY. ANY MODIFICATIONS TO UPGRADE SYSTEM SHALL BE INCLUDED IN THE BASE BID. ALL EXIT SIGNS ARE TO BE INSTALLED IN A VISIBLE LOCATION. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL WHERE NECESSARY TO DROP A SIGN BELOW AN OBSTRUCTION 6.ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL THE NECESSARY CLIPS, SCREWS, RIVETS, ETC., TO SECURELY FASTEN RECESSED LAY-IN LIGHTING FIXTURES TO CEILING FRAMING GRID WORK. 7.ALL LIGHTING FIXTURES SHALL BEAR THE APPROPRIATE UL LABEL FOR THE APPLICATION AND UNION LABEL WHERE REQUIRED. 8.ALL LIGHTING FIXTURES SHALL BE SHATTER PROOF OR COMPLETELY SHIELDED/COVERED. 9.CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS, EQUIPMENT, S.E.S., AND EXTENT OF ELECTRICAL ITEMS. PROVIDE AND INCLUDE IN BID ALL REQUIRED ITEMS TO ENSURE PROPER SCOPE OF WORK. SWITCH BANK DETAIL 1 K FLOOD LIGHT LIGHTOLIER # LT08RWF830BK 8.9 W 3000K LINE VOLTAGE LED TRACKHEAD TO ACCENT GLASS GUARD AT COUNTER AND CHIP / COOKIE DISPLAY AND DINING AREA ------ LOCATE DIRECTLY NEXT TO NETWORK CABINET ABOVE MANAGERS DESK KLITE #2114 KLITE #2115 KLITE #2112 3.6V EMERGENCY LIGHTING 0.6W (120V) WITH BATTERY BACK-UP COMBO EXIT SIGN AND EMERGENCY LIGHT 3W WITH BATTERY BACK-UP WITH (1) 2W REMOTE CAPACITY PHILIPS CHLORIDE # VLLCR PHILIPS CHLORIDE # VLLU PHILIPS CHLORIDE # VLLCR2R (2) 1W LED (2) 1W LED COMBO EXIT SIGN AND EMERGENCY LIGHT 3W WITH BATTERY BACK-UP 3.6V (2) 1W LED 3.6V KLITE #8830 50W LED KEYED NOTES CONNECT NEW EXHAUST FAN TO LOCAL LIGHTING CIRCUIT AND SWITCH WITH SAME. # 1 J 120 CENTERED IN WIDTHRECESSEDRECESSED LED DOWNLIGHT WITH 5" ROUND LENSED PHILIPS LIGHTOLIER LYTECASTER LED 5", ROUND LENSED FRESNEL LENSLITE (1) 20W LED---- E-2 LIGHTING PLAN ELECTRICAL I-5 REMOTE LAMP HEADS & MOUNTING PLATE LIGHTOLIER # CRMP2 (PLATE) IT86 (HEAD) (2) 8W IT86 6V DC INVERTER GLASS LENS SURFACE WALL PROVIDE EMERGENCY BATTERY BACKUP FOR EMERGENCY EGRESS REQUIREMENTS B 120 INDIRECT WALL GRAZING LUMINAIRE FOR EXTERIOR/INTERIOR USE INDIRECT WALL GRAZING LUMINAIRE FOR EXTERIOR USE BRIAN 15 3000K MTI BLACK INTEGRAL35W LED -- IP66 RATED, 120/277V INPUT, 0-10V DIMMING 10 YEAR WARRANTY SURFACE TYPICAL MOUNTING HEIGHTS 1/4" = 1'-0"2 CONTRACTOR TO INSTALL 1 AMP CURRENT LIMITER ON TRACK LIGHTING CONTRACTOR TO INSTALL HALF AMP CURRENT LIMITER ON TRACK LIGHTING 2 JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com NORTH 3 SINGLE LINE DIAGRAM N.T.S.A CONTRACTOR TO SITE VERIFY ALL EXISTING CONDITIONS PRIOR TO BID AND MAKE ALL ALLOWANCES IN BID NECESSARY FOR COMPLETE INSTALLATION OF ELECTRICAL SERVICE. M M M M M M M EXISTING PANEL "P1" RENAMED PANEL "A" 250 AMPS NEW PANEL "B" 120/208 V 3PH/4W 250 AMPS (4)#250, (1)#4G, 2-1/2" C. E-3 PANELS SCHEDULES ELECTRICAL GENERAL REQUIREMENTS A. E.C. SHALL COORDINATE FULLY WITH OTHER CONTRACTORS ASSOCIATED WITH THIS PROJECT TO VERIFY ALL EQUIPMENT LOCATIONS, CONNECTION REQUIREMENTS, ELEVATIONS AND LOCATIONS OF PIPES, CONDUITS AND DUCTS TO PREVENT CONFLICTS DURING CONSTRUCTION. ANY RELOCATION OR REROUTING OF EQUIPMENT, PIPES, CONDUITS, DUCTS OR MATERIALS RESULTING FROM A LACK OF COORDINATION BETWEEN CONTRACTORS WILL BE AT THE CONTRACTORS EXPENSE. B. EQUIPMENT ROUGH-INS SHOWN ARE ACCURATE TO THE BEST OF DESIGNER'S KNOWLEDGE. HOWEVER, IN SOME INSTANCES, THE OWNER OR SUPPLIER MAY SUBSTITUTE OR THE EQUIPMENT ITEM MAY VARY FROM WHAT IS SHOWN. THEREFORE,THE CONTRACTOR SHALL VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION. FAILURE OF THE E.C. TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR. C. E.C. SHALL FURNISH AND INSTALL ALL REQUIRED DISCONNECT SWITCHES AND MOTOR STARTERS TO ALL EQUIPMENT. D. E.C. SHALL REVIEW WITH OWNER AND SIGNAGE MANUFACTURER, REQUIREMENTS AND LOCATION OF BUILDING SIGNAGE PRIOR TO CONSTRUCTION AND PROVIDE 120VAC CONNECTION AS REQUIRED. E. E.C. SHALL PROVIDE AS-BUILT DRAWINGS AT JOB COMPLETION TO ARCHITECT. F. ALL WORK SHALL BE INSTALLED PER ALL GOVERNING CODES. G. SUBCONTRACTOR IS TO SUPPLY AND INSTALL ALL BLOCKING REQUIRED TO HANG/MOUNT LIGHTS INCLUDING RESTROOM FIXTURES. BLOCKING IS TO BE FIRE RATED IF REQUIRED BY LOCAL CODES. H. SUBCONTRACTOR IS TO SUPPLY AND INSTALL UNISTRUT AND 3/8" THREADED ROD TO HANG/SUPPORT LIGHTING. RACEWAY SYSTEMS A. ALL BRANCH CIRCUIT WIRING SHALL BE ROUTED IN EMT, RIGID OR ELECTRICAL METALLIC TUBING. USE STEEL SET SCREW TYPE FITTINGS ON ALL EMT. B. CONDUIT SHALL BE SUPPORTED AT INTERVALS PER NEC REQUIREMENTS AND SHALL BE SECURELY FASTENED TO BUILDING WITH AN APPROVED FASTENING SYSTEM. C. ALL NEW CONDUIT TO BE CONCEALED IN WALLS. PATCH/PAINT IF NECESSARY. WIRING, WIRING DEVICES, PLATES AND GROUNDING A. ALL WIRING SHALL CONSIST OF COPPER CONDUCTORS WITH THERMOPLASTIC INSULATION RATED FOR SIX HUNDRED (600) VOLTS. ALL WIRING INSULATION SHALL BE HEAT AND MOISTURE RESISTANT TYPES THW, THWN, OR THHN FOR INTERNAL AND DRIVE LOCATIONS. B. MINIMUM CONDUCTOR SIZE SHALL BE NO. 12 AWG FOR ALL BRANCH CIRCUITS (I.E. RECEPTACLES, LIGHTING, EQUIPMENT POWER, ETC.). MINIMUM CONDUCTOR SIZE SHALL BE NO. 10 AWG FOR ALL FEEDER CIRCUITS TO MECHANICAL EQUIPMENT (I.E U-1, CONDENSERS, ETC.) C. ALL SPLICED OR CONNECTIONS SHALL BE MADE IN OUTLET BOXES, JUNCTION BOXES OR EQUIPMENT WHERE ACCESSIBLE. D. CONDUCTORS SHALL BE PULLED WITHOUT THE USE OF OIL OR GREASE. WIRE PULLING LUBRICANTS WHICH ARE APPROVED FOR USE WITH CONDUCTOR INSULATION MAY BE USED. CARE SHALL BE TAKEN IN PULLING WIRE TO ASSURE THAT MAXIMUM ALLOWABLE PULLING TENSION OF WIRE IS NOT EXCEEDED. WIRING WITH DAMAGED CONDUCTORS OR INSULATION WILL NOT BE ACCEPTED. E. ALL PLUG-IN DEVICES SHALL BE GROUNDED TYPE. A GROUNDING JUMPER FROM RECEPTACLE TO OUTLET BOX SHALL BE INSTALLED WHERE CONDUIT SYSTEM IS USED FOR GROUND. F. INSTALL INSULATED GREEN GROUNDING CONDUCTOR (NO. 12 AWG MINIMUM) IN RACEWAYS AS INDICATED ON DRAWINGS AND IN ALL NON-METALLIC RACEWAYS PER NEC. G. SWITCHES FOR LIGHTING CONTROL SHALL BE INDUSTRIAL GRADE. DEVICES AND PLATES TO MATCH WALLS IN THE DINING ROOM, WHITE DEVICES WITH STAINLESS PLATES IN THE KITCHEN AND RESTROOMS. SIDE WIRED ONLY, TWENTY (20) AMP, ONE HUNDRED TWENTY/TWO HUNDRED SEVENTY-SEVEN (120/277) VOLT. H. DUPLEX RECEPTACLES SHALL BE INDUSTRIAL GRADE, THREE (3) WIRE GROUNDING, WHITE COLOR, FINDER GROOVE, TWENTY (20) AMP, NEMA 5-20R 125 VAC. DEVICES AND PLATES TO MATCH WALLS IN THE DINING ROOM, WHITE DEVICES WITH STAINLESS STEEL PLATES IN THE KITCHEN AND RESTROOMS. I. PLATES SHALL BE FURNISHED AND INSTALLED FOR ALL WIRING DEVICES, TELEPHONE OUTLETS, JUNCTION BOXES, ETC. J. PLATES FOR FLUSH MOUNTED DEVICES SHALL MATCH THE SURROUNDING FINISH, EXCEPT IN THE KITCHEN/PREP AREA AND RESTROOMS WHERE THEY SHALL BE STAINLESS STEEL SURFACE MOUNTED BOXES SHALL BE GALVANIZED STEEL. K. E.C. SHALL BE RESPONSIBLE FOR PROPERLY BALANCING ALL BRANCH CIRCUITS BETWEEN THE PHASES OF THE SYSTEM; REGARDLESS OF CIRCUITING INDICATED. L. ALL DUPLEX RECEPTACLES INSTALLED IN KITCHEN AND PREPERATION AREA ARE TO BE GFCI RATED, WHERE NOT PROTECTED BY A GFCI CIRCUIT BREAKER. M. THERE WILL BE NO MC RUNNING HORIZONTALLY OVER 12" IN LENGTH IN ANY EXPOSED AREA OR AREAS VISBILE TO THE CUSTOMER. ANY HORIZONTAL CONDUIT MUST BE LEVEL. G E N E R A L R E Q U I R E M E N T S JI M M Y J O H N ' S 25-892-819 03-18-25 SM ST O R E # T B D - F U E L E D D E S I G N YE L M , W A 9 8 9 5 7 10 1 0 E A S T Y E L M A V E , S U I T E H 1 9 0 1 C o m m o n w e a l t h C o u r t , S u i t e A L o u i s v i l l e , K Y 4 0 2 9 9 o. 502.426.8020 f . 502.426.0527 box1@bayusdesign.com