Loading...
YELM HS PORTABLES_WRI SP PROJECT PREPARED FOR Wayne’s Roofing, Inc. www.waynesroofing.com SUBMITTALS WRI PROJECT MAILING: PO BOX 2287 SUMNER, WA 98390 PHYSICAL: 13105 HOUSTON ROAD EAST SUMNER, WA 98390 PHONE: 253-863-4455 FAX: 253-863-8311 DRAWINGS 1 PRODUCT DATA 2 CERTIFICATION 3 WARRANTIES 4 WRI PROJECT Wayne’s Roofing, Inc. www.waynesroofing.com MAILING: PO BOX 2287 SUMNER, WA 98390 PHYSICAL: 13105 HOUSTON ROAD EAST SUMNER, WA 98390 PHONE: 253-863-4455 FAX: 253-863-8311 Wayne’s Roofing, Inc. www.waynesroofing.com DRAWINGS Da t e Dr a w n B y Re v . Sc a l e Jo b N o . Sh e e t N . T . S . Wa y n e ’ s R o o f i n g , I n c . 13 1 0 5 H o u s t o n R o a d Su m n e r , W A 9 8 3 9 0 Su m ( 2 5 3 ) 8 6 3 -44 5 5 S e a ( 2 0 6 ) 5 7 5 -00 7 8 Fa x ( 2 5 3 ) 8 6 3 -83 1 1 CH E C K E D B Y W a y n e ' s R o o f i n g , I n c . M a i l i n g : P O B o x 2 2 8 7 S u m n e r , W A 9 8 3 9 0 Ph y s i c a l : 1 3 1 0 5 H o u s t o n R o a d E S u m n e r , W A 9 8 3 9 0 Su m : ( 2 5 3 ) - 8 6 3 - 4 4 4 5 S e a ( 2 0 6 ) 5 7 5 - 0 0 7 8 Fa x ( 2 5 3 ) 8 6 3 - 8 3 1 1 Wayne's Roofing, Inc. Mailing: PO Box 2287 Sumner, WA 98390 Physical: 13105 Houston Road E Sumner, WA 98390 Sum: (253)-863-4445 Sea (206) 575-0078 Fax (253)863-8311 DATE DRAWN BY REVISION JOB NUMBER SCALE SHEETCHECKED BY Wayne’s Roofing, Inc. www.waynesroofing.com PRODUCT DATA Copyright ©2021 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 06/21 • Doc# Elastobase V ELASTOBASE® V SBS (ELASTOMERIC) BASE SHEET www.polyglass.us PRODUCT DESCRIPTION Elastobase V is a high quality Styrene-Butadiene-Styrene (SBS) modified bitumen roofing membrane reinforced with a high quality fiberglass mat which provides strength and excellent dimensional stability. The proprietary SBS compound offers quality waterproofing and weathering physical properties. Elastobase V is designed for use as a base ply layer in multi-layer low-slope assemblies. The top and bottom surfaces are available in sand or factory applied burn-off film. Elastobase V is intended for use as a base ply or interply membrane and designed to be installed in mechanically attached, hot asphalt, heat-welded, or as part of cold-applied system. When the top of membrane is surfaced with film, Elastobase V can be used as a base sheet in self-adhered systems. TYPICAL APPLICATIONS • Use as a base or interply membrane in multi-ply low-slope roofing assemblies. • Fastened anchor sheet, hot asphalt, cold adhesives or heat fused. • New roofing, re-roofing and flashing reinforcement. FEATURES AND BENEFITS • Versatile for multiple application methods. • Fiberglass mat enhances strength and dimensional stability. • Provides a strong and durable substrate for other roofing membrane plies. TECHNICAL DESCRIPTION* Physical Properties ASTM Method ASTM Value Typical Performance Peak Load at 0°F [-18°C]:D5147 70 lbf/in [12.3 kN/m]121lbf/in [21.2 kN/m] - MD 102 lbf/in [17.9 kN/m] - XMD Elongation at Peak Load at 0°F [-18°C]:D5147 1%5% - MD 5% - XMD Peak Load at 73°F [23°C]:D5147 30 lbf/in [5.3 kN/m]78 lbf/in [13.7 kN/m] - MD 45 lbf/in [7.9 kN/m] - XMD Elongation at Peak Load at 73°F [23°C]:D5147 2%5% - MD 4% - XMD Ultimate Elongation at 73°F [23°C]:D5147 3%33% - MD 39% - XMD Tear Strength at 73°F [23°C]:D5147 35 lbf [156 N]150 lbf [667 N] - MD 79 lbf [351 N] - XMD Low Temperature Flexibility [maximum]:D5147 0°F [-18°C]PASS Dimensional Stability, max %:D5147 0.50%0.1% - MD 0.1% - XMD Compound Stability [pass/fail]:D5147 215°F [102°C]PASS *The properties in this table are “as manufactured” unless otherwise noted PRODUCT DATA** Net Coverage (Approx) ......200 ft 2 (18.5 m2) Weight (Approx) .............106 lbs (48 kg) Thickness (Nominal) .......80 mils (2.0 mm) Roll Size .......65'8" × 39 3⁄8" (20 m × 1 m) Rolls/Pallet .......................................20 **All values are nominal at time of manufacturing APPLICABLE STANDARDS • ASTM D6163, Type I, Grade S • UL Classified • FM Approved • ICC ESR-2018 • Florida Building Code • Miami-Dade County Approved • Texas Department of Insurance TM PRODUCT CODES • EB20PP (Film/Film) • EB20SP (Sand/Film) • EB20PS (Film/Sand) • EB20SS (Sand/Sand) Copyright ©2021 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 06/21 • Doc# Elastobase V ELASTOBASE® V SBS (ELASTOMERIC) BASE SHEET www.polyglass.us APPLICATION INSTRUCTIONS Elastobase V is intended to be used as a base sheet or interply for new or re-roof applications. Elastobase V may be applied directly to non-combustible substrates. Elastobase V requires the installation of an interply and/or compatible granulated cap sheet to complete the roofing system. • Apply over clean, dry, dust and debris-free substrates. Prime concrete decks and required substrates prior to application with PG 100 Fast-Drying Asphalt Primer. Consult Polyglass Technical Service if alternate primer is allowed. • When re-roofing, remove all prior roofing materials down to a clean, dust free substrate. Remove unused or abandoned through-roof penetrations. • All substrates shall be designed with proper expansion devices. • Wood decks shall have all joints cross blocked and/or properly supported. • Installation of Elastobase V should not adversely affect the ventilation of existing construction. • Do not apply directly to existing shingles or other unacceptable roof coverings. • Bonded application of Elastobase V: 1. Start at the low point of the roof. 2. Unroll the material and allow to relax. Cut into preferred workable lengths. 3. Install with a solid mopping of Type III or Type IV asphalt or with an application of PG 350 Mod Bit Adhesive. 4. Position successive membranes providing a minimum 6" end lap and 3" side lap. • Details and flashing may be installed using hot asphalt, cold application or torch techniques. Check project details for proper installation requirements. • For detailed drawings and recommended installation procedures of typical roof segments, such as drip edge and T-joint conditions, please refer to our website at, www.polyglass.us. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Waco, TX • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.us General Line: (888) 410-1375 (954) 233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 802-8017 Questions? technical@polyglass.com Product Disclaimer: Unless otherwise incorporated into or part of a supplemental manufacturer’s warranty, Polyglass warrants its product(s) against manufacturing defects in its product that directly results in leakage for a period of 2 years. Refer to safety data sheet (SDS) for specific data and handling of our products. All data furnished refers to standard production and is given in good faith within the applicable manufacturing and testing tolerances. Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time without prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products under conditions beyond its own control. For most current product data and warranty information, visit www.polyglass.us + ; FANACO" FASTENERS DRIVEN TO PERFECTION s �- 11,0� lh x .113 ' ---.. Copyright ©2019 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 03/19 • Doc# PG 100 PG 100 FAST-DRYING ASPHALT PRIMER www.polyglass.us PRODUCT DESCRIPTION PG 100 is a general purpose penetrating asphalt primer used to promote adhesion prior to the application of hot-mopped, cold-applied, and self-adhesive membrane systems as well as roof cements, mastics, and asphalt-based adhesives. USES • Designed to promote superior adhesion of roofing materials • As a protective surface for metal, masonry, stucco, parapet walls, curbs and base flashings • As a damp proofing compound for below grade walls • As a protective coating on the inside of planter boxes TYPICAL PHYSICAL PROPERTIES TEST PROPERTY TEST VALUE TEST PROCEDURE Weight/gal (lb)7.5 – 8.0 ASTM D1475 VOC (gm/L)< 350 Calculated Solids Weight (%)64 – 68 ASTM D1644 Flash Point (°F)> 105 PMCC APPLICATION INSTRUCTIONS Surface Preparation: • Surfaces to receive primer must be clean, dry and free from any foreign matter such as dirt, oils, grease or other debris that could inhibit the adhesion capabilities of the newly installed products. • On existing roofs, inspect roof substrate condition. Blisters, buckles, and raised edges should be cut out and repaired for a smooth surface. • Check all flashings, edges, drains, valleys and vents and repair as needed. • Do not apply to wet or visibly damp surfaces, or surfaces previously covered with coal tar based products or Kynar® finishes. Application: • Mix well prior to application. • Application Rate: Apply approximately .5 gallon per 100 square feet for most applications. Actual rate may vary depending on product application and surface conditions. • PG 100 may be applied by high pressure spray or roller application methods. • Avoid over-application and excessive build up of primer. • To improve adhesion with coatings, adhesives and cements, allow drying time of approximately 2–8 hours before applying any other product over primer. • Apply only when ambient temperatures are 45º F and rising. Cold weather could result in uneven application and improper curing of product. Do not apply if there is a threat of inclement weather within 24 hours of application. • Do not heat container or attempt to thin this product. Cold weather will cause product to stiffen, making application more difficult. APPLICABLE STANDARDS • Meets or exceeds the requirements of ASTM D41 Asphalt Primer, Type II (Pails) • Meets of exceeds the requirements of ASTM D41 Asphalt Primer, Type I (Spray Can) • FM Approved • Texas Department of Insurance • Florida Building Code Approval • Miami-Dade County Product Control Approved PACKAGING • 0.9 Gallon (3.4 Liters) Can • 4.75 Gallon (17.9 Liters) Pail • 14 oz (396 G) Spray Can Copyright ©2019 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 03/19 • Doc# PG 100 PG 100 FAST-DRYING ASPHALT PRIMER www.polyglass.us Storage and Cleaning: • Shelf life is 24 months if stored in original unopened containers. • All containers should be sealed when not in use. • Store between 40°F and 100°F. • If temperatures are cold, store product in a heated area overnight. • DO NOT HEAT WITH AN OPEN FLAME. • Observe normal safeguards for storing and handling of this product prior to and during application. • Clean equipment and overspray with water. • Clean hands with waterless hand cleaner. • Application tools and equipment can be cleaned with odorless mineral spirits solvent. Recirculate through lines and spray equipment guns until residual coating is removed. • DO NOT USE WATER OR RECLAIMED SOLVENTS. For Professional Use Only - Keep out of the reach of children. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Phoenix, AZ • Waco, TX • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.us General Line: (888) 410-1375 (954) 233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 802-8017 Questions? technical@polyglass.com Product Disclaimer: Unless otherwise incorporated into or part of a supplemental manufacturer’s warranty, Polyglass warrants its product(s) against manufacturing defects that result in the material not complying with product specifications for a period of 12 months. Refer to safety data sheet (SDS) for specific data and handling of our products. All data furnished refers to standard production and is given in good faith within the applicable manufacturing and testing tolerances. The product user, and not Polyglass, is responsible for determining the suitability and compatibility of our products for the user’s intended use. For the most current product data and warranty information, visit www.polyglass.us Copyright ©2024 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 07/24 • Doc# Elastoflex SA V Plus ELASTOFLEX SA V PLUS SELF-ADHERED SBS (ELASTOMERIC) ROOF MEMBRANE www.polyglass.us PRODUCT DESCRIPTION Elastoflex SA V Plus membrane is a robust, self-adhered, elastomeric base ply low-slope roofing product manufactured using patented ADESO® dual-compound self-adhered technology, whereby a “true” Styrene-Butadiene-Styrene (SBS) modified asphalt compound is applied on the top layer and an aggressive self-adhesive compound is applied on the bottom layer. Elastoflex SA V Plus is built with a high quality reinforced fiberglass mat to ensure strength and excellent dimensional stability, providing a robust membrane that resists natural forces and other factors on the rooftop. Elastoflex SA V Plus membrane is finished with film that has laylines on the top surface and a split release film on the bottom surface. When used in conjunction with Elastoflex SA P or other approved Polyglass self-adhered cap sheet, Elastoflex SA V Plus provides cleaner application, improved application speed and removes the need for torches, hot asphalt or bonding adhesives on the job site. TYPICAL APPLICATIONS • Component of a Polyglass high performance extended warranty roofing system. • For use as a base or interply sheet with approved Polyglass roofing systems. • New construction or approved reroofing specifications for Polyglass roofing systems. • Job sites with limited access for special installation equipment or where using a propane torch, hot asphalt or adhesives is undesirable. FEATURES AND BENEFITS • Long-term adhesion directly to approved non-primed insulation, cover boards and wood decks* • Premium SBS compound formulation enhances weathering performance and low temp flexibility stability • Adhere approved SA cap/interply sheet directly to Elastoflex SA V Plus* • Quick dry-in of building and 90 day exposure time* protects property *See suitable substrates Polyglass Technical Bulletin #2012-02 TECHNICAL DESCRIPTION** Physical Properties ASTM Method ASTM Value Typical Performance Peak Load at 73°F (23°C)D5147 30 lbf/in (5.3 kN/m) 71 lbf/in (12.4 kN/m) - MD 51 lbf/in (8.9 kN/m) - XMD Peak Load at 0°F (-18°C)D5147 70 lbf/in (12.3 kN/m) 112 lbf/in (19.6 kN/m) - MD 74 lbf/in (13 kN/m) - XMD Elongation at Peak Load at 73°F (23°C)D5147 2%6% - MD 6% - XMD Elongation at Peak Load at 0°F (-18°C)D5147 1% 4% - MD 4% - XMD Ultimate Elongation at 73°F (23°C)D5147 3%53% - MD 76% - XMD Tear Strength at 73°F (23°C)D5147 35 lbf (156 N)136 lbf (605 N) - MD 98 lbf (427 N) - XMD Low Temperature Flexibility (maximum)D5147 0°F (-18°C)Pass Dimensional Stability, max %D5147 0.50%0.2% - MD 0.2% - XMD Compound Stability (pass/fail)D5147 215°F (102°C)Pass **The properties in this table are “as manufactured” unless otherwise noted. PRODUCT DATA*** Net Coverage (Approx) ...150 ft2 (13.9 m2) Weight (Approx) .................92 lbs (42 kg) Thickness (Nominal) .......100 mils (2.5 mm) Roll Size ........49'3" × 39 3⁄8" (15 m × 1 m) Rolls/Pallet ........................................25 ***All values are nominal at time of manufacturing APPLICABLE STANDARDS • ASTM D6163, Type 1, Grade S • UL Classified • FM Approved • ICC ESR-2018 • Florida Building Code • Miami-Dade County Approved • Texas Department of Insurance PRODUCT CODES • EF25SAPLQ Copyright ©2024 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 07/24 • Doc# Elastoflex SA V Plus ELASTOFLEX SA V PLUS SELF-ADHERED SBS (ELASTOMERIC) ROOF MEMBRANE www.polyglass.us APPLICATION INSTRUCTIONS Elastoflex SA V Plus is intended to be used as a base sheet or interply for new or re-roof low-slope applications when applied to acceptable insulations and/or coverboards for commercial structures. Elastoflex SA V Plus may also be applied directly to approved wood deck substrates of non-occupied spaces such as carports, sheds, canopies, etc. For additional substrate requirements and information refer to Polyglass published “Suitable Substrates for Self-Adhered (SA) Membranes.” • Apply Elastoflex SA V Plus membrane only in dry weather and when air and surface temperatures are 40°F (5°C) and rising. • Apply over clean, dry, dust and debris-free substrates. Prime required substrates prior to application with PG 100 Fast-Drying Asphalt Primer or WB-3000 Water-Based Primer. Consult Polyglass Technical Service if alternate primer is allowed. • When re-roofing, remove all prior roofing materials down to a clean debris free substrate and properly close off all abandoned roof penetrations. • Concrete or Steel decks shall be designed with proper expansion devices. • Wood decks shall be properly supported by the structural framing. • Ensure the installation of Elastoflex SA V Plus does not prevent the ventilation of existing construction • Do not apply directly to shingles or other granulated surface roof systems. • While installing Elastoflex SA V Plus: 1. Start at the low point of the roof. 2. Unroll the material and allow to relax. 3. Start by removing the first 18–24" of release film. 4. Press the membrane into place with firm and even pressure. Roll the edges with a silicone hand roller to ensure complete adhesion. 5. Gradually remove the remaining release film applying pressure from the center to the edges as you go. 6. Position successive rolls providing a minimum 6" end lap and 3" side lap. Laps can be sealed for additional water tightness with a hot air welder. 7. Roll with an 75# split-face linoleum roller. Take care on sloped roofs by securing the roller and applicator with the appropriate safety equipment. Intermittent rolling is recommended to ensure complete contact to underlying surface. 8. When addressing the field details of the seaming intersection treatment (cutting 45 degree at T-Joints), additional care must be taken to ensure the required Polyglass detail is performed. Complete installation instructions can be found on packaging or by calling Polyglass Technical Services. Details and flashing may be installed using Elastoflex SA V Plus with a hot air welder or with PG 500 Roof Cement or PolyPlus 50 Premium Modified Wet/Dry Cement. Check project details for proper installation requirements. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Waco, TX • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.us General Line: (888) 410-1375 (954) 233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 794-9659 Questions? technical@polyglass.com Product Disclaimer: Unless otherwise incorporated into or part of a supplemental manufacturer’s warranty, Polyglass warrants its product(s) against manufacturing defects in its product that directly results in leakage for a period of 2 years. Refer to safety data sheet (SDS) for specific data and handling of our products. All data furnished refers to standard production and is given in good faith within the applicable manufacturing and testing tolerances. Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time without prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products under conditions beyond its own control. For most current product data and warranty information, visit www.polyglass.us Copyright ©2025 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 03/25 • Doc# Elastoflex SA P ELASTOFLEX SA P SELF-ADHERED SBS (ELASTOMERIC) GRANULATED CAP SHEET www.polyglass.us PRODUCT DESCRIPTION Elastoflex SA P is a self-adhered Styrene-Butadiene-Styrene (SBS) granulated cap sheet for use in low- slope roofing. Elastoflex SA P is manufactured using Polyglass’ patented ADESO® Dual-Compound Self- Adhered Technology. With this technology, a “true” elastomeric modified asphalt compound is applied to the top of the membrane and a proprietary self-adhesive SBS compound is applied to the bottom. Elastoflex SA P is constructed with a durable non-woven polyester reinforcement that provides flexibility and dimensional stability as well as excellent tear and puncture resistance. The top surface of Elastoflex SA P has a granular finish with mulitple color options. Elastoflex SA P also features SEALLap® ULTRA, a granule-free side lap with self-adhesive compound and FASTLap®, granule free end lap. Each of these patented features provide for greater ease of applications as well as improved long-term performance. Elastoflex SA P can be used as part of a Polyglass warranted multi-ply system with Elastoflex SA V, Elastoflex SA V Plus, or other top film-surfaced Polyglass base sheets to provide a cleaner application, improved application speed and removes the need for torches, hot asphalt or bonding adhesives on the job site. TYPICAL APPLICATIONS • Self-adhered cap sheet and flashing membrane on standard new construction and re-roofing applications. • Self-adhered directly over an acceptable substrate or as part of a multi-ply system. • Job sites with limited access for special installation equipment or where using a propane torch, hot asphalt or adhesives is undesirable. FEATURES AND BENEFITS • Excellent long-term adhesion. • Application to multiple substrates and base/interply membranes. • Non-woven polyester mat delivers excellent tear and puncture resistance. • FASTLap granule free end lap provides faster, stronger seams. • SEALLap ULTRA granule free selvage edge with self-adhesive compound for an immediate, long- term monolithic seam. TECHNICAL DESCRIPTION* Physical Properties ASTM Method ASTM Value Typical Performance Peak Load at 0°F (-18°C)D5147 ≥ 70 lbf/in (12.3 kN/m) 140 lbf/in (24.5 kN/m) - MD 93 lbf/in (16.3 kN/m) - XMD Elongation at Peak Load at 0°F (-18°C)D5147 ≥ 20%50% - MD 62% - XMD Peak Load at 73°F (23°C)D5147 ≥ 50 lbf/in (8.6 kN/m) 99 lbf/in (17.3 kN/m) - MD 64 lbf/in (11.2 kN/m) - XMD Elongation at Peak Load at 73°F (23°C)D5147 ≥ 35%52% - MD 55% - XMD Ultimate Elongation at 73°F (23°C)D5147 ≥ 38%59% - MD 69% - XMD Tear Strength at 73°F (23°C)D5147 ≥ 55 lbf (246 N)138 lbf (614 N) - MD 98 lbf (436 N) - XMD Dimensional Stability (maximum)D5147 ≤ 1%0% Low Temperature Flexibility (maximum)D5147 0°F (-18°C)Pass Compound Stability (maximum)D5147 Pass/Fail Pass Adhesion to Plywood (min at 40°F)D1970 2.0 lbf/ft 4.0 lbf/ft Adhesion to Plywood (min at 75°F)D1970 12.0 lbf/ft 27.0 lbf/ft Granule Embedment (maximum loss)D5147 ≤ 2 g 1 g *The properties in this table are “as manufactured” unless otherwise noted. PRODUCT DATA** Net Coverage (Approx) ............100 ft2 (9.3 m2) Weight (Approx) ......................86 lbs (39 kg) Thickness (Nominal) .............140 mils (3.5 mm) Roll Size ............32'10" × 39 3⁄8" (10 m × 1 m) Rolls/Pallet ..............................................25 **All values are nominal at time of manufacturing APPLICABLE STANDARDS • ASTM D6164, Type I, Grade G • UL Classified • FM Approved • ICC ESR-2018 • Florida Building Code • Miami-Dade County Approved • Texas Department of Insurance • Materials Release 1320b (HUD) PRODUCT CODES • ESA35##Q ##denotes color code - see Available Colors Copyright ©2025 by Polyglass U.S.A., Inc. and all rights are reserved. Edition Date: 03/25 • Doc# Elastoflex SA P ELASTOFLEX SA P SELF-ADHERED SBS (ELASTOMERIC) GRANULATED CAP SHEET www.polyglass.us AVAILABLE COLORS Black (BL) Buff (BU) Chestnut (CH) Grey Slate (SL) Oak (OA) White (WH) Red Blend (RB) Pine Green (PG) Heather Blend (HB) Weatherwood (WW) APPLICATION INSTRUCTIONS Elastoflex SA P is intended to be used as the primary weathering surface in new or re-roof applications. Elastoflex SA P is to be applied as the uppermost layer of a multi-ply roof system over a compatible Polyglass base and/or interply membrane. Elastoflex SA P may also be applied directly to approved wood deck substrates of non-occupied spaces such as carports, sheds, canopies, etc. For additional substrate requirements and information refer to “Suitable Substrates for Self-Adhered Membranes” Polyglass Technical Bulletin. • Apply Elastoflex SA P membrane only in dry weather and when air and surface temperatures are 40°F (5°C) and rising. • Apply over clean, dry, dust and debris-free substrates. Prime required substrates prior to application with PG 100 Fast-Drying Asphalt Primer or alternative ASTM D41 primers as approved by Polyglass • All substrates shall be designed with proper expansion devices. • Wood decks shall have all joints cross blocked and/or properly supported. • Installation of Elastoflex SA P should not adversely affect the ventilation of existing construction. • Do not apply directly to existing shingles or other unacceptable roof coverings. • While installing Elastoflex SA P: 1. Start at the low point of the roof. 2. Unroll the material and allow to relax. 3. Start by removing the first 18–24" of release film. 4. Press the membrane into place with firm and even pressure. Roll the edges with a silicone hand roller to ensure complete adhesion. 5. Gradually remove the remaining release film applying pressure from the center to the edges as you go. 6. Position successive rolls using the 5" FASTLap at the endlap and 3" SEALLap ULTRA granule free side lap. Ensure a watertight seal. 7. When addressing the field details of the seaming intersection treatment (cutting 45 degree at T-Joints), additional care must be taken to ensure the required Polyglass detail is performed. Complete installation instructions can be found on packaging or by calling Polyglass Technical Services. • Details and flashing may be installed with a hot air welder or with PG 500 Roof Cement or PolyPlus 50 Premium Modified Wet/Dry Cement. Refer to manufacturer’s published details for proper design and installation of detail work. • For detailed drawings and recommended installation procedures of typical roof segments, such as drip edge and T-joint conditions, please refer to our website at, www.polyglass.us. MANUFACTURING FACILITIES • Fernley, NV • Hazleton, PA • Waco, TX • Winter Haven, FL CORPORATE HEADQUARTERS Polyglass U.S.A., Inc. 1111 West Newport Center Drive Deerfield Beach, FL 33442 www.polyglass.us General Line: (888) 410-1375 (954) 233-1330 Customer Service: (800) 222-9782 Technical Service: (866) 794-9659 Questions? technical@polyglass.com Product Disclaimer: Unless otherwise incorporated into or part of a supplemental manufacturer’s warranty, Polyglass warrants its product(s) against manufacturing defects in its product that directly results in leakage for a period of 5 years. Refer to safety data sheet (SDS) for specific data and handling of our products. All data furnished refers to standard production and is given in good faith within the applicable manufacturing and testing tolerances. Polyglass U.S.A., Inc., reserves the right to improve and change its products at any time without prior notice. Polyglass U.S.A., Inc. cannot be held responsible for the use of its products under conditions beyond its own control. For most current product data and warranty information, visit www.polyglass.us. Product Data Sheet… Innovative Flashings Saving the Contractor Time Since 2000 FlashCo® Manufacturing, Inc. 866-323-5274 * 150 Todd Road, Suite 400 * Santa Rosa, CA 95407 * Fax: 707-824-5858 * FlashCoMfg.com FlashCo® is a trademark of FlashCo Manufacturing, Inc. ©2011 FlashCo’s® Cylindrical Flashing Cylindrical Penetration and Protrusion Flashing Trade Names: Roof Flashing, Pipe Flashing, Pipe Boot, Solar Flashing, Roof Jack, Plumbers Flashing, Plumbers Boot, Pipe Vent Flashing Description Cylindrical Pipe Penetration Flashings are fabricated using a variety of materials. FlashCo manufactures standard cylindrical boots and flashings using 60 mil reinforced TPO and PVC single ply membrane and various metals such as 4 pound Lead, 16 ounce Copper, 26 gauge Zinc and 24 gauge G- 90 coated Galvanized Steel. Intended Uses Cylindrical flashings are used for pipe penetrations such as plumbing vents and for protrusions such as solar stanchions. Cylindrical flashings are designed to just fit over the penetration or protrusion. Flashings are used to “flash” or waterproof a penetrations and protrusions on roofs effectively tying the flashing into the roofing system. Cylindrical flashings are commonly used on a low slope and steep slope roofs. Caulking and a stainless steel hose clamp can be used to counter flash or as an alternative a separate counter flashing is used such as a storm collar or cap. See FlashCo’s FlashCap™ Product Data Sheet. Features and Benefits Prefabricated cylindrical flashings save the contractor time in the field eliminating the need to field fabricate. A factory fabricated part is of higher quality because it is fabricated in a controlled environment and has a warranty. Cylindrical shaped flashings offer an aesthetically pleasing appearance as they blend in better than its conical counterpart. Cylindrical flashings parallel the shape of the penetration and protrusion minimizing airspace and the potential for condensation. Cylindrical shaped flashings are offered in standard pipe sizes and made to (90) degree angle or to the angle or pitch specified. Application Installation of cylindrical flashings shall be installed in accordance with the recommendations and specifications of the roofing material manufacturer or architect. The cylindrical shaped flashings that FlashCo fabricates are typically for TPO, PVC, Built up Roofing, and most residential systems. Storage and Packaging Store material in a dry area away from sources of physical damage and chemical contamination. Standard Single-Ply boots are typically packaged in plastic bags and boxed. Metal flashings are usually packaged loose on a pallet or in a crate. Typical Properties and Characteristics Material Type Nominal Thickness Thickness Inches Weight/ Sq. Foot TPO 60 mil .060” .25 lbs. PVC 60 mil .060” .25 lbs. Lead 4 Pound .063” 4 lbs Copper 16 Ounce .022” 1 lb Zinc 26 Gauge .019” .77 lbs Galv G90 26 Gauge .022” .91 lbs Galv G90 24 Gauge .028” 1.16 330 Central Ave. I Clark, NJ 07066 I 800.526.4236 I Fax 732.388.9422 | www.karnakcorp.com Updated: 05.04.20 ROOFING 19 Ultra Rubberized Flashing Cement (Wet/Dry) *Read Safety Data Sheet before using this product.* DESCRIPTION: 19 Ultra Flashing Cement is the next generation elastomeric flashing cement. Scientifically compounded with a selection of rubber reinforced asphalt, mineral fibers, and refined solvents. KARNAK 19 Ultra is manufactured to a heavy pliable consistency for ease of application by trowel. 19 Ultra provides a durable elastomeric coating of greater strength, excellent adhesion and high resistance to water and weathering. 19 Ultra is composed of special chemical ingredients which give it a unique water displacement quality (Wet/Dry). KARNAK 19 Ultra dries to a tough, flexible, waterproof and corrosion proof rubber coating which gives maximum protection and excellent performance over wide ranges of temperature and weather conditions. KARNAK 19 Ultra is available in 3 consistencies: Summer, Semi and Winter grade. USES: 19 Ultra Flashing Cement is a general purpose asbestos-free flashing cement for repairing leaks in shingles, concrete, metal or asphalt roofs, SBS and APP modified bitumen membranes flashings on walls, chimneys, flues, skylight flashings, downspouts and cornices. 19 Ultra is excellent for sealing cracks in concrete and brick, as a joint filler for precast roof slabs, for repair, patch and flashing detail on SBS and APP modified membranes, and for general purpose use in maintenance of exposed buildings and structures. FEATURES, BENEFITS & ADVANTAGES:  Rubberized - elastomeric  Wet or dry application  Improved low-temperature flexibility  Improved water and weather resistance  Will not shrink or crack  Smooth, easy to apply rubber-like trowel consistency  Excellent adhesion  Excellent resistance to sag at high roof temps.  Ready to apply - no mixing required  Greater strength  Cures faster than regular flashing cements  VOC compliant  ASTM compliant  Sticks under water the first time  Can use with fiberglass membrane under water SURFACE PREPARATIONS: All surfaces should be clean, dry and free from oil, grease, dust, dirt, loose paint or other foreign matter. Excess water should be removed, if possible, before application of 19 Ultra. Recommended application temperature is 40°F to 120°F. If applying at temperatures lower than 40°F, the substrate must be free of moisture and/or ice crystals. APPLICATION: Spread 19 Ultra Rubberized Flashing Cement to an average thickness of 1/8” (approximately 8 gallons per square) and press tightly into joints, seams or cracks. To repair large cracks, breaks and blisters: 1. Spread 19 Ultra Rubberized Flashing Cement over the damaged area. 2. Embed 34 Asphalt Saturated Cotton Fabric, 31 Fiberglass Membrane or 5540 Resat-Mat reinforcement. 3. Apply another coat of 19 Ultra Rubberized Flashing Cement over the entire patch. COVERAGE RATE: Apply each application at an average thickness of 1/8” (8 gallons per 100 sq. ft.) PHYSICAL PROPERTIES: 1. Consistency: A smooth, rubber-like trowel consistency that will readily spread on and adhere to vertical and horizontal surfaces without sagging. 2. Character of Dried Film: Excellent adhesion to masonry, steel, cured concrete, shingles, asphalt roofing, skylight flashings and a variety of other surfaces. 3. Film Performance Characteristics: The dried film retains its flexibility and ductility so that the coating will resist extreme variations in temperature and weather. 4. Sag Resistance: Excellent resistance to flow at high roof temperatures on vertical surfaces. 5. Homogenized: Thoroughly mixed and consistent throughout. 6. Consistency: 19 Ultra is always smooth and of a trowel consistency. CAUTION: Do not use near open flame. Avoid breathing solvent fumes and prolonged contact with skin. Do not take internally. If swallowed, do not induce vomiting. Call a physician immediately. Keep out of reach of children. Store in a heated room and keep container covered when not in use. Do not thin. Dispose of in an environmentally safe manner. Cover air intakes during application and while drying. Exterior use only. PACKAGING: Available in 5-gallon pails, 3-gallon buckets and 1-gallon cans and 10.1 oz. cartridges If further information is needed, contact KARNAK Technical services at 800-526-4236. PHYSICAL PROPERTIES & SPECIFICATIONS Weight per Gallon: 8.77 lbs. Solids by Weight: 74% Nominal Solids by Volume: 66% Nominal Color: Black Application Temp.: 40°F to 120°F Service Temp (Cured Film): 15°F to 180°F VOC Content: 270 g/L MAX ASTM D4586 Type I Class I & Class II ASTM D3409 SS-C-153 Type I Wayne’s Roofing, Inc. www.waynesroofing.com CERTIFICATIONS September 12, 2024 Waynes Roofing Inc. 13105 Houston Road Sumner, Washington 98390 United States RE: Polyglass Registered Contractor Status To Whom It May Concern, This letter is to confirm that Waynes Roofing Inc. is a current Polyglass Registered Contractor in good standing and retains the Polyglass Registered Contractor number 6095. As such, Waynes Roofing Inc. is eligible to offer Polyglass warranties and maintenance programs. Should you have any questions, please feel free to contact me. Regards, Jacquelynn (Jackie) Keough Warranty and Technical Services Supervisor Polyglass U.S.A., Inc. jkeough@polyglass.com CC: Registered Contractor File Wayne’s Roofing, Inc. www.waynesroofing.com WARRANTIES 20 YR PG RSW 112022 20 YEAR ROOFING SYSTEM WARRANTY (RSW) LIMITED NON-PRORATED, NO DOLLAR LIMIT (NDL) Owner’s Name: Roofing Contractor Name: Owner’s Address: Roofing Contractor Address: Building Name: Roofing Contractor Phone #: Building Address: Polyglass Registered Contractor #: Polyglass Product(s) Used: Product Method Sequence Roofing Specification Used: Project Size: Square Feet Completion Date: Term Warranty: Warranty Number: TERMS AND CONDITIONS: 1.Definitions: “POLYGLASS” shall mean POLYGLASS U.S.A., Inc., 1111 W. Newport Center Drive, Deerfield Beach, Florida 33442. “Owner” shall mean the original party listed above as Owner’s Name whose building the Polyglass roof membrane product is installed. 2.General Provisions: a) Except as otherwise stated herein, POLYGLASS warrants the roofing membrane against deficiencies as defined by POLYGLASS in the installed roofing system resulting in leakage for a period of 20 Years from the original installation completion date as indicated above. b) No representative of POLYGLASS shall have the authority to make any modifications, representations or oral agreements except as stated herein. c) The original installation of the roofing membrane must be in accordance with POLYGLASS current published specifications to the applicable system. 3.Term of Warranty: Except as indicated in paragraphs 2, 6, 8 and 12 hereof, this warranty is valid from the date of completion and acceptance by POLYGLASS as indicated above. 4.Claims Procedure: Polyglass shall have no obligation under this warranty unless Owner has promptly notified Polyglass in writing by Registered or Certified Mail. Direct all claims to Polyglass, U.S.A., Inc. 1111 W. Newport Center Drive, Deerfield Beach, Florida 33442, ATTN: Warranty Department. Any claim shall provide a copy of warranty and detailed information of the leakage and alleged defect. Polyglass must receive such notice within ten (10) days after discovery of the claimed defect, failure to notify will result in voiding of this warranty. If the claim is found to be a non-warrantied condition, Owner will be billed at a rate of $75.00 per Technical Representative, per hour for a two (2) hour minimum, plus round trip mileage per the IRS Tax Code. 5 Replacement Costs: POLYGLASS warrants to the original Owner that during the warranty period stated above, commencing on the date of completion stated herein, if notified of leakage, POLYGLASS through its authorized representative, shall observe the roof. If, after observation, POLYGLASS, at its sole discretion, determines that the leakage is the result of faulty material supplied by POLYGLASS, ordinary wear and tear, deficiencies in any or all of the POLYGLASS supplied component materials of the membrane system, or workmanship deficiencies in the proper application of the POLYGLASS supplied component materials, POLYGLASS shall remediate covered leakage conditions by means determined by POLYGLASS providing replacement products and reasonable labor required to properly repair or replace the damaged areas as determined by POLYGLASS. 6. Exclusions: This warranty is not an insurance policy or maintenance agreement. Routine inspections and maintenance are the Owner’s responsibility. Failure to follow the Building Owner Roof Maintenance Warranty Guidelines provided with this warranty will void the warranty. This warranty will become void and not apply if damage is the direct or indirect result of: a) acts of God or natural causes such as, but not limited to, lightning, hail, strong winds not to exceed 55 mph, floods, hurricanes, tornadoes, wind launched debris or earthquakes; b) fire; c) accidents; d) vandalism; e) negligence, misuse, or failure of Owner to provide reasonable maintenance to the roof; f) structural defects or other building movement; g) lack of positive drainage; h) exposure of the roofing to solvents and/or petroleum distillates such as, but not limited to xylene, toluene, or gasoline; i) the disregard of manufacturer’s handling procedures with respect to storing, handling and installing of roofing membrane; j) distortion, expansion or contraction of any non-published flashing design, or metal work; k) moisture infiltration not related to the roofing system or condensation due to design or a lack of any needed vapor retarder; l) traffic or storage of materials upon the roof; m) damage to the roofing membrane caused by installation of roof top or through roof systems such as but not limited to, a sprinkler system, water or air conditioning equipment, antenna, frame work for signs, water tower or other such items on the roof after the installation of the roofing membrane without prior written approval of POLYGLASS; n) inadequate performance of products not supplied or furnished by POLYGLASS, including but not limited to metal work, mechanical attachments and adhesives; o) tie-ins to existing roof systems; p) environmental and airborne contaminates; q) loss in part of whole of granule or other roof surfacing materials due to non-manufacturing related circumstances r) any exposed mastics or sealants; s) Damage or injury arising in any way from an actual or alleged discharge or release of any pollutant or waste; t) Damage or injury arising in any way from testing/sampling of the membrane, design and consulting errors or omissions. POLYGLASS is not responsible for leaks resulting from water entry from any other portion of the building or structure other than that having the Polyglass materials installed. 7. Cancellation of Warranty: This warranty shall become null and void if any of the following work is performed without prior written approval of Polyglass: a) any alterations or repairs to the roof of any magnitude, except of an emergency nature to remedy leakage; b) subsequent work on or through the roof, or c) changes in building usage; d) change in ownership of the building; e) any unauthorized damaging activity on or to the roof; f) failure to pay a Polyglass invoice for claim procedures not covered under the warranty. 8.Access to the Roof: Owner shall provide free, safe and reasonable access to the roof and related premises to an authorized representative of POLYGLASS during the term of this warranty. Owner shall be responsible for any and all expenses required to access roof, removing and replacing any walking pads or traffic surfaces, or other appurtenances built over the roof or other overburden if removal is necessary to investigate or repair any suspected problem in the roofing membrane. POLYGLASS retains the right to make core extractions and properly repair such extractions. The expenses for extractions are to be paid by POLYGLASS. Failure or refusal to provide such access or retain sampling will immediately and without other notification void all warranty coverage without further notification. 9.Commencement of Warranty: This warranty shall not become effective, nor will POLYGLASS have any obligation under this warranty until all monetary obligations for materials and services related to this installation or subsequent repairs, or site observations are paid in full by OWNER. 10.Waiver: POLYGLASS’ failure at any time to enforce any conditions stated herein shall not be construed as a waiver of any provision of this warranty. 11.Assignment of Warranty: This warranty is eligible to be assigned by original owner only to one successive party provided a) owner shall notify POLYGLASS in writing of the new party’s name and address 30 days prior to building sold or up to a maximum of six (6) months after the sale and b) owner pays a transfer fee of $500.00 plus any out-of-pocket cost for travel, lodging and meals determined necessary by POLYGLASS to re-observe roof prior to transfer. Upon receipt of the foregoing, POLYGLASS will advise owner within thirty (30) days of its approval of such proposed assignment. 12.Additional Repairs: In the event repairs are required which are not covered by this warranty, POLYGLASS will advise OWNER of such repairs to be made at OWNER’s expense. If the required repairs are promptly made by OWNER, this warranty shall remain in effect for the unexpired portion of its original term. If OWNER does not make the required repairs promptly, not to exceed 30 days of being notified, this warranty shall automatically terminate without further notice from POLYGLASS. In the event POLYGLASS pays for repairs which are required due to the acts or omissions of others, or other reasons not covered by this warranty, POLYGLASS shall be subrogated to all rights of recovery of owner to the extent of the amount of the repairs. 13. Design Disclaimer: Because POLYGLASS does not practice Engineering or Architecture, neither the issuance of this Warranty nor any review of the Project Documents, building or other construction conditions by POLYGLASS representatives shall constitute any acceptance or implied warranty by POLYGLASS of such plans, specifications and construction, or in any way constitute an extension of the terms and conditions of this Warranty. Roof Observations performed by POLYGLASS are for the benefit of POLYGLASS. Upon request POLYGLASS may make a site observation report available as required by Project Documents. POLYGLASS does not supervise nor is it responsible for a roofing contractor’s work except to the extent stated herein. This constitutes your entire express warranty for the products or system of products purchased. To the extent permitted by law, all other warranties, whether expressed or implied, including, but not limited to the implied warranties of MERCHANTABILITY and FITNESS FOR A PARTICULAR PURPOSE are EXCLUDED. ANY IMPLIED WARRANTIES ARISING BY OPERATION OF LAW ARE LIMITED IN DURATION TO THE TERM OF THIS WARRANTY. POLYGLASS WILL NOT PAY OR BE LIABLE UNDER ANY CIRCUMSTANCES FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR EXEMPLARY DAMAGES, OR FOR LOST PROFITS OR BUSINESS INTERRUPTION LOSS. YET, SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, OR THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. No implied warranty can be modified by any course of dealing, course of performance or usage of trade. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. NO REPRESENTATION, PROMISE, AFFIRMATION OR STATEMENT BY ANY EMPLOYEE OR AGENT OF POLYGLASS WILL BE ENFORCEABLE AGAINST POLYGLASS UNLESS IT IS SPECIFICALLY INCLUDED IN THIS WARRANTY. POLYGLASS’ AGENTS HAVE NO AUTHORITY TO GIVE WARRANTIES BEYOND THOSE PROVIDED IN THS WARRANTY.ALL RIGHTS AND DUTIES ARISING UNDER THIS WARRANTY SHALL BE GOVERNED BY FLORIDA LAW. Warranty as provided by Polyglass is solely based upon information provided within the Product Registration/Warranty Request Form. Information presented and determined as incomplete or inaccurate, shall result in this warranty being null and void. Signed on Behalf of Polyglass U.S.A. Inc. Date SA M P L E 20 YR PG RSW 112022 OWNER MAINTENANCE WARRANTY GUIDELINES MAINTENANCE AND CARE FOR YOUR POLYGLASS PRODUCT There are various items associated with your roof/coating system that are NOT covered under the manufacturer’s warranty. Some can have a direct impact on the performance, life cycle and watertight integrity of the roofing/coating system. The Owner has a responsibility to regularly maintain the roofing system. It is recommended that a file of records be maintained related to all roof and roof-top associated activities. Such file should contain the original warranty, invoices related to the original roof installation, repair invoices, a log of roof inspections and any roof-top activities such as service to roof top mechanical equipment. Polyglass recommends the Owner institute a roof log for all parties accessing the roof, regardless of who or the purpose, that they are required to sign. This protects you, the owner from: 1) unwanted roof traffic and 2) any damage caused can, many times, be traced back to the responsible party. Industry organizations such as, National Roofing Contractors Association (NRCA) and the Asphalt Roofing Manufacturers Association (ARMA) recommend that roofs have a visual inspection at a minimum rate of two (2) times per year by a qualified party. Many Polyglass Registered Contractors offer this service for a nominal fee. Such visual inspections are generally recommended in the spring and fall. It is a good practice to have the roofs inspected after severe weather conditions such as: hail, strong winds, hurricanes, blizzards, ice storms, etc. Proper precautions should be followed during inspections to prevent against trip/fall accidents. Guidelines for Roof Inspection & Generalized Remedial Repairs 1. Remove roof-top debris, such as; leaves, branches, dirt, rocks, bottles, trash, etc., that has accumulated. 2.Clean gutters, downspouts, drains and scuppers. Make sure water freely flows from the roof. No standing water should remain on the roof surface within 48 hours after the last precipitation. 3.Examine all metal flashing areas for rusting or damage that may have been caused by traffic, wind, hail, snow, ice, etc. All damaged, loose, or poorly sealed materials must be repaired by a Polyglass Registered Contractor or otherwise approved by Polyglass. 4.All exposed mastics and sealants regardless of purpose or function, are maintenance items to be maintained and remediated by the Owner, including pitch pan and metal flashing sealants. 5.Examine all adjacent areas to the roof, parapet walls and adjoining structures. Damage to items such as masonry, failing mortar joints, loose or missing sealants, loose stone/tile caps, loose and improperly sealed counterflashing, etc. often causes leaks that are inadvertently blamed on the roofing system and not provided for by the manufacturer’s warranty. Not only does this cost the roofing manufacturer time in the investigation of problems not associated with the product, it may cost the Owner time and money. Many manufacturers, including Polyglass, may charge an Owner for the time spent to investigate non-warranty related problems. These items need to be repaired by the properly trained personnel to avoid any unnecessary charges or voiding of warranty coverage. Unauthorized repairs will void the manufacturer’s warranty. 6.Granule loss of mineral surface membranes is typical, and not a manufacturing defect; and therefore would not be covered under the terms of the warranty. In cases of granule loss that is determined by Polyglass as atypical, Polyglass reserves the right to apply additional surfacing as the remedy. 7.When repairing items to the roof/coating product(s), associated items, or building structure, be sure to use precaution and properly protect the roof/coating product(s) from damage. 8.Examine roof-top equipment, such as; air condition units, condensers, exhaust fans, antennas and other roof-top items for damage. Check for leaking oil, damaged flashings or loose parts/equipment that could cause puncture damage to the roof/coating product(s). All units shall be checked to assure they are sound, watertight and not be displaced by wind events. 9.Check the building for excessive movement or settlement. Improper placement or omission, or the need for expansion joints, could cause splits or stress in the roof/coating system, drastically reducing the life cycle of the system. 10.All work directly or indirectly related to the roof/coating system, where the materials need to be repaired; i.e. new curbs, units, exhaust fans, antenna installation, repairs, etc., must be accomplished by a current Polyglass Registered Contractor. Failure of the Owner to utilize a Polyglass Registered Contractor will result in immediate termination of the warranty without further notification. Conditions beyond those noted herein above should be provided to Polyglass, in writing within 15 days of discovery for recommendations. To avoid interruption and/or cancellation of your warranty coverage, compliance with the above Owner Maintenance Warranty Guideline is recommended. SA M P L E Roofing Guarantee Whereas, WAYNE’S ROOFING, INCORPORATED, of Sumner, Washington, herein called “the Contractor,” has completed application of the following roof: Owner: SAMPLE Address of Owner: Type and Name of Building: Location Area of Roof: Date of Completion: Date Guarantee Expires: Whereas, at the inception of such work the Contractor agreed to guarantee the aforesaid roof against faulty materials or workmanship for a limited period and subject to the conditions herein set for th: Now, Therefore, the Contractor hereby Guarantees, subject to the conditions herein set forth, that during a period of TWO (2) years from the date of completion of said roof, it will, at its own cost and expense, make or cause to be made such repairs to said roof and composition flashing resulting solely from faults or defects in materials or workmanship applied by or through the Contractor as may be necessary to maintain said roof in watertight condition. This guarantee is made subject to the following conditions: 1. Specifically excluded from this guarantee is any and all damage to said roof, the building or contents caused by the acts or omissions of other trades or contractors; lightning, windstorm, hailstorm, or other unusual; phenomena of the eleme nts; foundation settlement; failure or cracking of the roof deck; defects or failure of material used as a roof base over which th e roof is applied, faulty construction of parapet wall, copings, chimneys, skylights, vents, supports, or other parts of the building; vapor condensation beneath the roof; penetrations for pitch boxes; or fire. If the roof is damaged by reason of any of the foregoing this guarantee shall thereupon become null and void for the balance of the guarantee period unless such damage is repaired by the Contractor at the expense of the party requesting such repairs. 2. The Contractor is not liable for consequential damages to the building or contents resulting from any defects in said roof or composition flashing. 3. No work shall be done on said roof, including, but without limitation, work in connection with flues, vents, drains, sign braces, railing, platforms or other equipment fastened to or set on the roof, and no repairs or alterations shall be made to said roof, unless the Contractor shall be first notified, shall be given the opportunity to make the necessary roofing application recommendations with respect thereto, and such recommendations are complied with. Failure to observe this condition shall render this guarantee null and void. The Contractor shall be paid for time and material expended in making recommendations or repairs occasioned by the work of others on said roof. 4. This guarantee shall become null and void if the roof is used as a promenade or work deck or is sprayed or floo ded, unless such use was originally specified and the specification is noted in paragraph 8 below. Areas that pond water shall not be covered by this guarantee. 5. This guarantee shall not be or become effective unless and until the Contractor has been paid in full for said roof in accordance with the agreement pursuant to which such roof was applied. 6. This guarantee shall become null and void unless the Contractor is promptly notified of the alleged defect in materials or workmanship and provided an opportunity to inspect the roof. 7. This guarantee is in lieu of all other guarantees or warranties, express or implied 8. Additional conditions or exclusions: Excludes sheet metal flashings, gutters, wall cladding, and related work which was not installed as a part of roofing contractor’s work scope. In Witness Whereof, this instrument has been duly executed this day of , 20XX WAYNE’S ROOFING, INC. P.O. BOX 2287 13105 HOUSTON ROAD SUMNER, WASHINGTON 98390 (253) 863-4455 / waynesroofing.com BY AUTHORIZED REPRESENTATIVE Brian Butler, Vice President / CSO