Timberland Yelm Permit Set 25_06-021. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO BECOME FULLY AWARE OF ANY AND ALL CONDITIONS RELATED TO THE SITE AND EXISTING BUILDING CONDITIONS THAT MAY AFFECT THE COST OR SCHEDULING OF CONSTRUCTION ACTIVITIES, PRIOR TO SUBMITTING A BID. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE INCLUDING THOSE SHOWN ON RECORD DRAWINGS, AND CONDITIONS RELATED TO THE LOCATION OF EXISTING UTILITIES AND SERVICES BEFORE COMMENCING WORK AND BE RESPONSIBLE FOR THE ABOVE. ALL DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT IMMEDIATELY. 2. DO NOT SCALE DRAWINGS OR DETAILS -- USE GIVEN DIMENSIONS. CHECK DETAILS FOR LOCATION OF ALL ITEMS NOT DIMENSIONED ON PLANS. DIMENSIONS ON PLANS ARE TO FACE OF EXISTING FINISHES, FACE OF NEW STUDS, DOOR AND WINDOW OPENINGS, GRIDLINE OR CENTERLINE. U.N.O. NEW DOORS AND CASED OPENINGS WITHOUT DIMENSIONS ARE TO BE (4.5") FROM FACE OF ADJACENT WALL ON THE HINGE SIDE OF DOOR. 3. NEW DOORS AND CASED OPENINGS WITHOUT DIMENSIONS ARE TO BE (4.5'') FROM FACE OF ADJACENT FINISHED WALL ON THE HINGE SIDE OF DOOR. 4. THE DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW AND APPROVAL BY THE ARCHITECT AND THE STRUCTURAL ENGINEER. 5. BUILDING SYSTEMS AND COMPONENTS NOT SPECIFICALLY DETAILED SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. NOTIFY THE ARCHITECT OF ANY RESULTING CONFLICTS. 6. ALL WORK SHALL CONFORM TO APPLICABLE BUILDING CODES AND ORDINANCES. IN CASE OF ANY CONFLICT WHEREIN THE METHODS OR STANDARDS OF INSTALLATION OR THE MATERIALS SPECIFIED DO NOT EQUAL OR EXCEED THE REQUIREMENTS OF THE LAWS OR ORDINANCES, THE LAWS OR ORDINANCES SHALL GOVERN. CONFORM TO AGENCY INSPECTOR'S COMMENTS AND CORRECTIONS. NOTIFY THE ARCHITECT OF ALL CONFLICTS IMMEDIATELY & BEFORE PROCEEDING, AND ESPECIALLY IF INSPECTOR'S REQUIREMENTS CHANGE OR ADD TO APPROVED PLANS AND CONTRACT DOCUMENTS. 7. COORDINATE ALL OPERATIONS SUCH AS AREAS USED FOR MATERIAL STORAGE, PARKING, ACCESS TO AND FROM WORK AND TIMING OF WORK WITH THE ARCHITECT AND OWNER. 8. SOME ITEMS OR SYSTEMS INCLUDED IN THE CONSTRUCTION DOCUMENTS ARE TO BE "BIDDER DESIGNED" OR ARE PROVIDED BY OTHERS. THE ARCHITECT AND CONSULTING ENGINEERS WILL REVIEW ALL BIDDER DESIGN SUBMITTALS AND WILL DETERMINE IF THE SUBMITTAL IS IN CONFORMANCE WITH THE GENERAL DESIGN CONCEPT. THIS REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY TO CONFORM TO THE REQUIREMENTS OF ALL CODES AND THE CONSTRUCTION DOCUMENTS. THE CONTRACTOR SHALL COORDINATE THE PLACEMENT OF BIDDER DESIGNED ITEMS WITH THE STRUCTURAL SYSTEM AND FRAMING. CONFLICTS SHALL BE BROUGHT TO THE ARCHITECTS ATTENTION PRIOR TO BID AND THE REQUIRED MODIFICATIONS INCLUDED IN THE BID PRICE. 9. CONCEPTUAL BIDDER DESIGN INFORMATION IS INCLUDED THROUGHOUT THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE INSTALLATION OF THEIR WORK. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL DRAWINGS AND ANY CONSULTING ENGINEER(S) OR OTHER SUPPLEMENTARY DRAWINGS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION BY WRITTEN NOTIFICATION FOR CLARIFICATION. ANY WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR AT HIS/HER OWN EXPENSE AND AT NO EXPENSE TO THE OWNER OR ARCHITECT. 10. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL AND LOCAL GLAZING STANDARDS AND THE GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THESE REQUIREMENTS. IF THE GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARDS, HE/SHE SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING. NO CLAIMS FOR EXTRAS FOR COMPLYING WITH THE STANDARDS WILL BE ENTERTAINED REGARDLESS OF THE CONTENT OF THE DRAWINGS AND SPECIFICATIONS. 11. NEW CEILINGS AND EXISTING SUSPENSION SYSTEMS SHALL BE STABILIZED AGAINST LATERAL SEISMIC MOVEMENT IN ACCORDANCE WITH CODE REQUIREMENTS. PROVIDE LIGHTING TIE WIRES PER CODE. 12. CONCEAL TO THE GREATEST EXTENT POSSIBLE PIPE, CONDUITS, DUCTS, VENTS, ETC. ALL SUCH LINES SHALL BE CONCEALED OR FURRED AND FINISHED, UNLESS NOTED AS EXPOSED CONSTRUCTION IN DRAWINGS. OFFSET STUDS WHERE REQUIRED SO THAT FINISHED WALL SURFACES WILL BE FLUSH. PAINT OR FINISH ALL EXPOSED EQUIPMENT & ELEMENTS. 13. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 14. ALL WOOD FRAMING DETAILS AND CONNECTIONS (SHOWN AND NOT SHOWN) SHALL BE CONSTRUCTED TO CODE STANDARDS. ALL LIGHT GAUGE METAL STUDS AND FRAMING (SHOWN AND NOT SHOWN) SHALL BE INSTALLED PER THE STANDARDS AND DETAILS PUBLISHED BY THE STEEL STUD MANUFACTURER'S ASSOCIATION. 15. ALL WOOD IN DIRECT CONTACT WITH CONCRETE, OR EXPOSED TO WEATHER, OR GIRDERS LESS THAN 18" FROM GRADE SHALL BE PRESSURE TREATED WITH AN APPROVED PRESERVATIVE & SHALL BE IDENTIFIED WITH THE STAMP OF THE AMERICAN WOOD PRESERVERS INSTITUTE. USE BUILDING PAPER @ JOIST ENDS TO PREVENT CONTACT WITH CONCRETE. 16. FIRE BLOCKING SHALL BE PROVIDED AT MID-HEIGHT OF ALL STUD WALLS AND PARTITIONS OVER 10 FT. IN HEIGHT, AT THE CEILING AND FLOOR LEVELS, AT ALL INTERCONNECTIONS BETWEEN VERTICAL AND HORIZONTAL SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS AND COVE CEILINGS, AND AT 10 FT INTERVALS AS REQUIRED. ACOUSTICAL ALUMINUM CLAD WOOD AREA DRAIN ABOVE FINISHED FLOOR AUTHORITY HAVING JURISDICTION AGGREGATE ALUMINUM ALUMINUM ARCHITECTURAL ASBESTOS ASPHALT BOARD BUILDING BLOCKING BEAM BOTTOM OF BOTTOM CATCH BASIN CORNER GUARD CEILING CAULKING CLOSET CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONTINUOUS COMPRESSION CRAWL SPACE DOUBLE DETAIL DRINKING FOUNTAIN DIAMETER DIMENSION DISPENSERS DOWN DOOR DOWNSPOUT DRAWING EACH EXPANSION JOINT ELEVATION ELECTRICAL EMERGENCY ELECTRICAL PANELBOARD EQUAL EQUIPMENT EXISTING EXISTING EXPOSED EXTERIOR EXT. INSUL. FINISH SYSTEM FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FIRE HOSE FINISH FLOOR FLASHING FLUORESCENT FACE OF FACE OF CONCRETE FACE OF FINISH FURNISHED BY OWNER AND INSTALLED BY CONTRACTOR FURNISHED BY OWNER AND INSTALLED BY OWNER FACE OF STUDS FACE OF WALL FIREPROOF FIRE RETARDANT TREATED FLOOR SINK FOOT OR FEET FOOTING FURRING GAUGE GALVANIZED GLASS GLAZED/GLAZING GLUE LAM BEAM GYPSUM SHEATHING BOARD GYPSUM WALL BOARD GYPSUM H.B. H.C. HDWD. H.M. HORIZ. HR. HGT., HT. H.W.H. I.B.C. INSUL. INT.,INTER. JAN. LAM. LH MAX. MECH. MTL. MFR. MH. MIN. MIR. MISC. N.I.C. NO., # N.T.S. O/ O.C. OFD O.H. PERF. P.LAM. PLWD. PR. P.T. PTD. P.T.D. QUAN. R RAD. R.D. REF. REINF. REQ. RH RM. R.O. S.A.M. S.C./SC SF , S.F. SH. SHEATH. SHLF. SIM. SPEC. SQ. ST STD. STL. STOR. STRUCT. SUSP. T TEMP. T.S. T.P.H. TYP. U.N.O. V.B. W.C. WD. W/ W/O WP. W.R.B. WSCT. ACOUS. ACW A.D. A.F.F. A.H.J. AGGR. AL ALUM. ARCH. ASB. ASPH. BD. BLDG. BLKG. BM. B.O. BOT. C.B. CG CLG. CLKG. CL. CLR. C.M.U. COL. CONC. CONT. CPRSN. C.S. DBL. DTL., DET. D.F. DIA. DIM. DISP. DN DR DS. DWG. EA. E.J. EL., ELEV. ELECT. EMER. E.P. EQ. EQPT. (E), E. EXIST. EXPO. EXT. E.I.F.S. FDN. F.E. F.E.C. F.F. F.H. FIN. FL. FLASH. FLUOR. F.O. F.O.C. F.O.F. F.O.I.C. F.O.I.O. F.O.S. F.O.W. FPRF. F.R.T. F.S. FT. FTG. FURR. GA. GALV. GLS GL G.L.B. G.S.B. GWB GYP HOSE BIB HOLLOW CORE HARDWOOD HOLLOW METAL HORIZONTAL HOUR HEIGHT HOT WATER HEATER INTERNATIONAL BUILDING CODE INSULATION INTERIOR JANITOR LAMINATE LEFT HAND MAXIMUM MECHANICAL METAL MANUFACTURER MANHOLE MINIMUM MIRROR MISCELLANEOUS NOT IN CONTRACT NUMBER NOT TO SCALE OVER ON CENTER OVER FLOW DRAIN OVER HEAD PERFORATED PLASTIC LAMINATE PLYWOOD PAIR PRESSURE TREATED PAINT PAPER TOWEL DISPENSER QUANTITY RISERS RADIUS ROOF DRAIN REFRIGERATOR REINFORCED, REINFORCING REQUIRED RIGHT HAND ROOM ROUGH OPENING SELF ADHERED MEMBRANE SOLID CORE SQUARE FEET SHEET SHEATHING SHELF SIMILAR SPECIFICATION SQUARE STAIN/STAINED STANDARD STEEL STORAGE STRUCTURAL SUSPENDED TREADS TEMPERED TUBE STEEL TOILET PAPER HOLDER TYPICAL UNLESS NOTED OTHERWISE VAPOR BARRIER WATER CLOSET WOOD WITH WITHOUT WATERPROOF OR WATERPROOFING WATER RESISTANT BARRIER WAINSCOT SITE LOCATION 0 A ELEVATION MARK MATCH LINE INTERIOR ELEVATION EXTERIOR ELEVATION REVISION MARK CENTERLINE NEW & EXISTING CONTOURS CUT LINE NEW EXISTING 1 1 A8.3 1 A1.0 1 A8.3 1 A8.3 1 A1.0 A3.0 1 A5.0 1 2 A GRIDLINE WALL SECTION BUILDING SECTION DETAIL DETAIL WINDOW MARKER PARTITION TYPE DOOR NUMBER PLUMBING FIXTURE TAG A 4 EXISTING BRANCH S O U T H 1 S T S T R E E T E Y E L M A V E N 16 PARKING STALLS 0 10 20 40 SCALE: 1" = 40'-0" ZONING CLASSIFICATION: ADJACENT LAND USE: OVERLAYS: MAX BLDG HEIGHT: (TABLE 504.3) PARKING REQUIRED: (TABLE 18.54.030) PARKING PROVIDED: CENTRAL BUSINESS DISTRICT NORTH: CENTRAL BUSINESS DISTRICT SOUTH: CENTRAL BUSINESS DISTRICT EAST: CENTRAL BUSINESS DISTRICT WEST: CENTRAL BUSINESS DISTRICT N/A 40'-0" 1 PER 300SF = 2,469/300 = 8.23 = 9 STALLS 16 STALLS (1 ADA) N ABBREVIATIONS GENERAL NOTES ZONING CODE DATA VICINITY MAP DRAWING INDEX SYMBOLS DIRECTORY SEPARATE OR DEFERRED PERMITS THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS REQUIRED EXCEPT FOR THE BUILDING PERMIT. THESE MAY INCLUDE BUT MAY NOT BE LIMITED TO: • ELECTRICAL • PLUMBING PROJECT DESCRIPTION TENANT IMPROVEMENT OF EXISTING SPACE. INTERIOR WORK TO INCLUDE INSTALLATION OF NON-STRUCTURAL WALLS, FINISHES AND FIXTURES. LEGAL DESCRIPTION MCKENZIES L 1 & 2 B 2 TGWW PTN VAC ST ADJ ORD #118 OWNER 624 SIMPSON AVE HOQUIAM, WA, 98550 P: (360) 533-4747 CONTACT: JONATHAN FISCHER E: JAFISCHER@TIMBERLANDBANK.COM LOCAL JURISDICTION CITY OF YELM 106 2ND ST. SE YELM, WA 98597 P: (206) 684-8600 APPLICANT/ARCHITECT DRIFTMIER ARCHITECTS, P.S. 7983 LEARY WAY NE REDMOND, WA 98052 P: (425) 881-7506 CONTACT: MICHAEL WINNICK E: MICHAEL@DRIFTMIER.COM PROJECT ADDRESS: PARCEL NUMBER: SITE AREA: BUILDING AREA: NUMBER OF STORIES: BUILDING HEIGHT: 101 E YELM AVE, YELM, WA 98597 64400200100 11,982 SF (0.28 ACRES) 2,469 SF (GROSS) 1 STORY +/- 24'-0'' (NO CHANGE) PROJECT DATA PROJECT DIRECTORY ARCHITECTURAL SHEETS REGISTERED ARCHITECT 9480 Michael Christopher Winnick STATE OF WASHINGTON ISSUE DATE: DRAWN BY: PROJECT MANAGER: SHEET NUMBER: REVISION SCHEDULE PROJECT NUMBER: SHEET NAME: ISSUE: 7983 LEARY WAY NE, REDMOND, WA 98052 (425) 881-7506 MAIL@DRIFTMIER.COM 6/ 2 / 2 0 2 5 4 : 4 1 : 1 0 P M TI M B E R L A N D B A N K Y E L M 10 1 E Y E L M A V E , Y E L M , W A 9 8 5 9 7 MW JP 06/02/2025 22419 A0.0 COVER SHEET PERMIT SET TIMBERLAND BANK YELM 06/02/2025 PERMIT SET 101 E YELM AVE, YELM, WA 98597 BUILDING CODE DATA APPLICABLE CODES: BUILDING CODES: ELECTRICAL CODE: MECHANICAL CODE: PLUMBING CODE: FIRE CODE: ENERGY CODE: ACCESSIBILITY CODES: OCCUPANCY GROUP (PER IBC 302): CONSTRUCTION TYPE (PER IBC 602): EXISTING HEIGHT: TOTAL BUILDING AREA: FIRE ALARM SPRINKLER SYSTEM EXITING: OCCUPANT LOAD (PER TABLE 1004.5): NO. OF EXITS REQD (PER TABLE 1006.2.1: NO. EXITS PROVIDED: EXIT WIDTH REQD.: MAX EXIT ACCESS TRAVEL DISTANCE (PER TABLE 1017.2): MAX COMMON PATH OF TRAVEL (PER TABLE 1006.2.1): MAX DISTANCE OF TRAVEL ACTUAL: PLUMBING FIXTURES NUMBER OF TOILETS REQUIRED (PER TABLE 2902.1): NUMBER OF TOILETS PROVIDED: DRINKING FOUNTAINS REQD: DRINKING FOUNTAINS PROVIDED: 2018 WASHINGTON BUILDING CODE (2018 IBC WITH AMENDMENTS) 2017 NATIONAL ELECTRICAL CODE 2018 INTERNATIONAL MECHANICAL CODE 2018 UNIFORM PLUMBING CODE 2018 INTERNATIONAL FIRE CODE 2018 WASHINGTON STATE ENERGY CODE ICC A117.1-2017; 2010 ADA STANDARDS B - BUSINESS V-B 24'-0'' (NO CHANGE) 2,469 SF NO NO 19 OCCUPANTS (BUSINESS) 1 1 0.2 X 19 = 3.8'' 200'-0'' 100'-0'' FOR OCCUPANCY B 57'-8'' 1 1 0 PER TABLE 2902.1 (LESS THAN 30 OCC.) 0 SHEET # SHEET NAMESHEET # SHEET NAME A0.0 COVER SHEET A0.1 CODE PLAN AND DEMO PLAN A2.1 FLOOR PLAN A2.2 REFLECTED CEILING PLAN A5.0 INTERIOR ELEVATIONS A5.1 SCHEDULES & DETAILS A5.2 DETAILS N SCALE 1" = 40'-0"SITE PLAN 1 NO. TYPE REVISION DATE CONTRACTOR PO BOX 616 AUBURN, WA 98071 P: (253) 332-5823 CONTACT: ALEX KOVAL E: CRAFTSMANSTRUCTURES@YAHOO.COM T T X'-X" MAX TRAVEL DISTANCE 5 4'- 1 0 " M A X T R A V E L D I S T A N C E 19 O C C . ND REF. 150 1138 SF 8 FINANCIAL AREA 150 110 SF 1 MANAGER 150 115 SF 1 BREAK ROOM 53 SF T1 150 140 SF 1 VAULT 300 162 SF 1 STORAGE 300 45 SF 1 IT 300 23 SF 1 HVAC 150 37 SF 1 VIEWING 150 379 SF 3 OPEN OFFICE 300 40 SF 1 ELEC/JAN. ROOM SQ. FT. XX XX ROOM IDENTIFICATION AREA OCCUPANT LOAD OCCUPANT LOAD FACTOR DEMO WALL DEMO PLUMBING FIXTURES, VANITY, RESTROOM ACCESSORIES, AND FLOORING DESK TO BE REUSED, RELOCATE PER FLOOR PLAN DESK TO BE REUSED, RELOCATE PER FLOOR PLAN REMOVE DESK AND PARTITION DEMO WINDOW AND PORTION OF WALL, PREP FOR NEW STOREFRONT DEMO PORTION OF TELLERLINE DESK DEMO CASEWORK, PATCH AND REPAIR WALL AS NEEDED DEMO LIGHT FIXTURE ABOVE VIEWING COUNTER, RELOCATE PER RCP DEMO WOOD TRIM CAP, PREP WALL FOR NEW FRAMING DEMO LIGHT FIXTURE DEMO LIGHT FIXTURE SALVAGE EXISTING DOOR FOR REUSE IN NEW BREAK ROOM 9" 3' - 0 " 1' - 2 " 3' - 0 " 3' - 9 " 11 ' - 8 " 1. THE CONTRACT FOR CONSTRUCTION CONTAINS ALL DEMOLITION WORK REQUIRED TO PREPARE THE BUILDINGS AND SITE FOR THE CONTRACTED CONSTRUCTIONS WORK. THE DEMOLITION DRAWINGS AND NOTES ARE PROVIDED TO OUTLINE THE GENERAL SCOPE OF WORK ONLY. THE CONTRACTOR MUST VISIT THE SITE PRIOR TO BIDDING AND DETERMINE THE FULL EXTENT OF THE WORK AND BE RESPONSIBLE FOR SAME. 2. THE CONTRACTOR IS TO VERIFY THE LOCATION OF ALL UTILITIES AND SERVICES TO THE SITE PRIOR TO BEGINNING ANY DEMOLITION OR SITE IMPROVEMENTS. 3. VERIFY ALL EXISTING UTILITIES AND EQUIPMENT, RELOCATE EXISTING UTILITIES AS REQUIRED FOR NEW WORK. NOTIFY OWNER & ARCHITECT OF CONFLICTS. 4. PROTECT ALL EXISTING CONSTRUCTION THAT IS TO REMAIN FROM DAMAGE DURING DEMOLITION. BRACE AND SUPPORT ALL WORK UNTIL IT IS PROPERLY REMOVED OR INCORPORATED INTO NEW CONSTRUCTION. 5. NO MATERIALS FROM THE DEMOLITION ARE TO BE STOCK PILED ON PLANTING AREAS OR PUBLIC RIGHT-OF-WAYS. ALL RUBBISH AND PRODUCTS OF DEMOLITION ARE TO BE REMOVED FROM THE SITE. 6. DO NOT CUT AND PATCH STRUCTURAL ELEMENTS IN A MANNER THAT COULD CHANGE THEIR LOAD-CARRYING CAPACITY OR LOAD-DEFLECTION RATIO. THROUGH THE ARCHITECT, VERIFY CUTTING AND PATCHING OF STRUCTURAL MEMBERS WITH STRUCTURAL ENGINEER. 7. REMOVE, REPLACE, PATCH, AND REPAIR MATERIALS AND SURFACES CUT OR DAMAGED DURING CUTTING AND PATCHING OPERATIONS, BY METHODS AND WITH MATERIALS SO AS NOT TO VOID EXISTING WARRANTIES. 8. PROVIDE TEMPORARY SUPPORT OF WORK TO BE CUT. 9. ADJACENT PROPERTIES, STREETS AND WALKS ARE TO BE PROTECTED FROM DAMAGE AT ALL TIMES. 10. ALL ITEMS THAT ARE DEMOLISHED OR REMOVED FROM THE SITE AND ARE NOT TO BE SALVAGED OR REINCORPORATED INTO THE CONSTRUCTION BELONG TO THE CONTRACTOR. 11. DURING THE COURSE OF WORK IF THE EXISTENCE OF HAZARDOUS MATERIALS IN THE STRUCTURE OR BUILDING IS OBSERVED (OTHER THAN THAT CALLED OUT IN THE HAZARDOUS MATERIALS SURVEY), THE CONTRACTOR SHALL PROMPTLY NOTIFY OWNER AND ARCHITECT REGARDING REMOVAL OR ENCAPSULATION OF THE HAZARDOUS MATERIAL AND CONTRACTOR SHALL NOT PERFORM ANY WORK PERTINENT TO THE HAZARDOUS MATERIAL PRIOR TO RECEIPT OF SPECIAL INSTRUCTIONS FROM OWNER THROUGH THE ARCHITECT. 12. REMOVE AND RELOCATE ALL ELECTRICAL, MECHANICAL AND PLUMBING WORK TO BE REMOVED. PATCH THE FLOOR SLAB AS REQUIRED. 13. REMOVE ALL EXISTING FLOOR FINISHES. 14. REMOVE ALL EXISTING PLUMBING FIXTURES AS NOTED PER DEMO PLAN. SAWCUT CONCRETE AND REMOVE FOR NEW UNDER SLAB PLUMBING AND UTILITY WORK. 15. REMOVE EXISTING FURNISHINGS, EQUIPMENT AND FIXTURES NOT REQUIRED FOR NEW WORK. COORDINATE ITEMS TO BE KEPT BY OWNER. SYMBOL OF ACCESSIBILITY WOM 5/ 8 " M I N T O 2 " M A X CORRESPONGING GRADE 2 BRAILLE 60" MAX 48" MIN UPPER CASE CHARACTERS RAISED 1/32" INTERIOR SIGN NOTES: 1. ALL INTERIOR SIGNAGE SHALL CONFORM WITH ICC/ANSI A117/1-2009 AND CH. 11 OF THE IBC. 2. SEE SPECIFICATION SECTION 10 1400 - SIGNAGE FOR DETAILED INFORMATION ON CHARACTER SPECIFICS. 3. SIGNAGE SHALL BE MOUNTED AT 48" A.F.F. TO THE BASELINE OF THE CHARACTER. ACCESSIBLE SIGN NOTES: 1. SYMBOLS OF ACCESSIBILITY SHALL CONTRAST WITH THEIR BACKGROUNDS, WITH EITHER A LIGHT SUMBOL ON A DARK BACKGROUND OR A DARK SYMBOL ON A LIGHT BACKGROUND. 2. SYMBOLS OF ACCESSIBILITY AND THEIR BACKGROUNDS SHALL HAVE A NONGLARE FINISH 3. RAISED CHARACTERS SHALL BE 48 INCHES MIN. ABOVE FLOOR, MEASURED TO THE BASELINE OF THE LOWEST RAISED CHARACTER AND 60 INCHES MAX. ABOVE THE FLOOR, MEASURED TO THE BASELINE OF THE HIGHEST RAISED CHARACTER. 4. THE SIGN SHALL BE ALONGSIDE THE DOOR AT THE LATCH SIDE. 5. SIGNS CONTAINING RAISED CHARACTERS AND BRAILLE SHALL BE LOCATED SO THAT A CLEAR FLOOR AREA OF 18 INCHES MIN BY 18 INCHES MIN, CENTERED ON THE RAISED CHARACTERS IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE CLOSED POSITION AND 45 DEGREE OPEN POSITION. ACCESSIBLE SIGN MOUNTING HEIGHT ACCESSIBLE SIGNS 9" MIN UNISEX RESTROOM 6" 8 5/8" RESTROOM SIGNS REGISTERED ARCHITECT 9480 Michael Christopher Winnick STATE OF WASHINGTON ISSUE DATE: DRAWN BY: PROJECT MANAGER: SHEET NUMBER: REVISION SCHEDULE PROJECT NUMBER: SHEET NAME: ISSUE: 7983 LEARY WAY NE, REDMOND, WA 98052 (425) 881-7506 MAIL@DRIFTMIER.COM 6/ 2 / 2 0 2 5 4 : 4 1 : 1 1 P M TI M B E R L A N D B A N K Y E L M 10 1 E Y E L M A V E , Y E L M , W A 9 8 5 9 7 MW JP 06/02/2025 22419 A0.1 CODE PLAN AND DEMO PLAN PERMIT SET N SCALE 1/8" = 1'-0"CODE PLAN 4 N SCALE N PLAN TRUE 1/4" = 1'-0"DEMO PLAN 1 SCALE N/ADEMO NOTES 2SCALE N/AINT. SIGNAGE NOTES 16 NO. TYPE REVISION DATE T 1. FURNITURE AND RECEPTION DESK ARE F.O.I.C. 2. PROVIDE FIRE EXTINGUISHERS AND CABINETS AS REQUIRED BY THE FIRE MARSHALL. COORDINATE AND RECEIVE APPROVAL FROM ARCHITECT PRIOR TO INSTALLATION. ANY NEW CABINETS WILL BE SEMI RECESSED. 3. VERIFY ALL EXISTING DIMENSIONS TO WALLS & COMPONENTS. DIMENSIONS MAY OR MAY NOT REFLECT EXISTING CONDITIONS. BRING CONFLICTS & VARIANCES TO THE ATTENTION OF ARCHITECT BEFORE PROCEEDING W/ NEW CONSTRUCTION. 4. EXISTING WALLS TO RECEIVE NEW FINISHES AND PAINT TO MATCH NEW. COORDINATE WITH OWNER. 5. EXISTING WALLS NOT MARKED WITH A WALL TAG MAY STILL REQUIRE NEW WORK INCLUDING BUT NOT LIMITED TO: PATCHING OF EXISTING HOLES, NEW GWB, NEW GWB DUE TO NEW CEILINGS OR CEILING REPAIR. EXISTING WALL FACES INSIDE TENANT SPACE TO RECEIVE NEW PAINT. 6. ANY CONFLICTS BETWEEN NEW CONSTRUCTION AND/OR EXISTING FEATURES, WHERE SHOWN DIMENSIONING WILL CAUSE ALTERATIONS TO MATERIALS OR SPECIFIED PRODUCTS, MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO INSTALLATION OF NEW CONSTRUCTION. 7. PROVIDE SMOOTH FINISH, READY FOR NON TEXTURED PAINTING FOR ALL GWB WORK. A5.0 7 T1 8 SH-1 PL-1, P-1 IT 4 HVAC 10 VAULT 2 FINANCIAL AREA 1 STORAGE 3 D/U WINDOW N/D VIEWING 11 ELEC./JAN. 5 (E) WH 19'-6"REF. 7'-0" V.I.F. 15'-11 1/8" V.I.F. 7'-3" 9'-7" V.I.F. 9'-1 5/8" 11'-4" 4'-2"2'-9" CO U N T E R CLR 1'-0 1/2" BREAK ROOM 7 SH-1 B-1 P-1 MANAGER 6 CPT-1 B-1 P-1 OPEN OFFICE 9 CPT-1 B-1 P-1 COUNTER A5.0 15 A5.019 W1 3 W2 2 1 EXTEND PARTIAL HEIGHT WALL TO CEILING, MATCH EXISTING BOARD AND BATTEN PATTERN, PAINT TO MATCH EXISTING (E) EP (E ) E P (E ) E P (E) SERVICE SINK (E) EP 3 C1 A1 A1 A1 C1 4 8 SH-1 CPT-1 PATCH AND REPAIR WALL AS NEEDED, PAINT TO MATCH EXISTING REFINISH END OF EXISTING TELLER LINE (E) DOOR RELOCATED EXTEND BOARD AND BATTEN WALL PANEL TO NEW WALL, PAINT TO MATCH EXISTING A5.012 (2) 2x4 POST (2) 2x4 POST LINE OF SOFFIT ABOVE 4X10 #2 DF BEAM EXISTING NEW CONSTRUCTION LEGEND ROOM NAME FINISH TAG LEGEND FINANCIAL AREA 1 CPT-1 B-1 PT-2 ROOM NUMBER FLOOR FINISH BASE FINISH WALL FINISH REGISTERED ARCHITECT 9480 Michael Christopher Winnick STATE OF WASHINGTON ISSUE DATE: DRAWN BY: PROJECT MANAGER: SHEET NUMBER: REVISION SCHEDULE PROJECT NUMBER: SHEET NAME: ISSUE: 7983 LEARY WAY NE, REDMOND, WA 98052 (425) 881-7506 MAIL@DRIFTMIER.COM 6/ 2 / 2 0 2 5 4 : 4 1 : 1 2 P M TI M B E R L A N D B A N K Y E L M 10 1 E Y E L M A V E , Y E L M , W A 9 8 5 9 7 MW JP 06/02/2025 22419 A2.1 FLOOR PLAN PERMIT SET SCALE N/AFLOOR PLAN NOTES 20 N SCALE N PLAN TRUE 1/4" = 1'-0"FLOOR PLAN 4 NO. TYPE REVISION DATE 1. CEILING FINISH AND MOUNTING HEIGHTS ARE DESIGNATED AS FOLLOWS: 2. CEILING HEIGHTS ARE TO FACE OF FINISH FOR SUSPENDED SYSTEMS AND FACE OF STRUCTURAL FRAMING FOR DIRECT ATTACHED SYSTEMS. 3. FOR LIGHT FIXTURE SCHEDULE SEE A5.1 4. PAINT ALL EXPOSED SOFFITS, GWB AND FASTENERS. NO NAILS OR FASTENERS WILL BE LEFT EXPOSED TO VIEW. 5. PROVIDE SMOKE DETECTORS AS REQUIRED PER CODE/AHJ. 6. COORDINATE WITH OWNER'S VENDOR FOR LIGHT FIXTURE SUPPLY. 10. ALL CEILING TO BE PROVIDED WITH ACOUSTICAL INSULATION ABOVE. TYPE HEIGHT FINISH RECESSED CAN LIGHT RECESSED LED WALL MOUNTED TOILET ROOM LIGHT SUPPLY AIR DIFFUSER RETURN AIR GRILL EXHAUST FAN EXIT SIGN - CEILING MOUNTED EXIT SIGN - WALL MOUNTED EQ EQ (E) FIXTURE RELOCATED EXTEND GWB CEILING AS NEEDED, PATCH AND REPAIR EXISTING EQ EQ EQ EQ D-1 W-1 NEW EXAUST FAN GWB 8'-6'' MATCH EXISTING (E) FIXTURES TO REMAIN GWB 8'-0'' MATCH EXISTING GWB 8'-0'' MATCH EXISTING NEW WALL UP TO CEILING X1 NEW GWB SOFFIT GWB 8'-0'' MATCH EXISTING EQ EQ EQ EQ EQ EQ EQ EQ EQ EQ L1 L1 L1 L1 EQ EQ L1 PATCH AND REPAIR CEILING AS NEEDED PATCH AND REPAIR CEILING AS NEEDED (E) LIGHT FIXTURES GWB 8'-0'' MATCH EXISTING L1 L1 L1 L1 L1 L1 OUTLINE OF (E) BEAM ABOVE V.I.F. EQ V.I.F. 5'-4" V.I.F. EQ (E) T&G VARIES MATCH EXISTING ROOM OPEN OFFICE TOILET ROOM MANAGER BREAKROOM TOTAL INTERIOR WATTS 366.78 221 SEE LIGHT FIXTURE SCHEDULE ON 16/A5.1 FOR PROPOSED WATTS. INTERIOR LIGHTING CALC PER C405.4.2(2): SF 379 53 110 115 WATTS/SF .66 .63 .37 .37 WATTS ALLOWED 250.14 33.39 40.7 42.55 WATTS PROPOSED 37 36 74 74 1. PROVIDE LIGHTS ON EMERGENCY CIRCUITS AS REQUIRED BY CODE OR LOCAL AUTHORITY. VERIFY LOCATIONS WITH ARCHITECT. 2. PROVIDE LIGHTS ON EMERGENCY CIRCUITS AS REQUIRED BY CODE OR LOCAL AUTHORITY. VERIFY LOCATIONS WITH ARCHITECT. LIGHTS AT THE ENTRIES NEED TO BE ON 24 HOURS. 3. PROVIDE EXIT PATHWAY LIGHTING: USE LIGHT FIXTURES ON BATTERY BACK UP OR WALL PACKS PER CODE. 4. PROVIDE EXIT & EMERGENCY FIXTURES & NIGHT LIGHTS AS SHOWN AND AS REQUIRED BY CODE / AHJ. REGISTERED ARCHITECT 9480 Michael Christopher Winnick STATE OF WASHINGTON ISSUE DATE: DRAWN BY: PROJECT MANAGER: SHEET NUMBER: REVISION SCHEDULE PROJECT NUMBER: SHEET NAME: ISSUE: 7983 LEARY WAY NE, REDMOND, WA 98052 (425) 881-7506 MAIL@DRIFTMIER.COM 6/ 2 / 2 0 2 5 4 : 4 1 : 1 3 P M TI M B E R L A N D B A N K Y E L M 10 1 E Y E L M A V E , Y E L M , W A 9 8 5 9 7 MW JP 06/02/2025 22419 A2.2 REFLECTED CEILING PLAN PERMIT SET SCALE N/ARCP NOTES 20 SCALE 1/4" = 1'-0"CEILING PLAN LEGEND 17 N SCALE N PLAN TRUE 1/4" = 1'-0"REFLECTED CEILING PLAN 4SCALELIGHTING CALCS - INT. 16N/A SCALE N/ALIGHT FIXTURE NOTES 19 NO. TYPE REVISION DATE NOTES: 1. FOR MATERIALS AND ROOM FINISH SCHEDULES REFER TO SHEET A6.0. 2. HORIZONTAL DIMENSIONING ON INTERIOR ELEVATIONS IS TO FACE OF FINISH ON WALLS. 3. SANITARY NAPKIN DISPOSALS ARE NOT TO BE INSTALLED IF IN DESIGNATED MEN'S TOILET ROOMS. 4. FOR TYPICAL ELEVATION MOUNTING HEIGHTS FOR RESTROOM FIXTURES SEE 5. ALL PANELS INSTALLED INTO PLAM ARE TO BE PAINTED TO CLOSELY MATCH PLAM. 6. FOR PLAM WAINSCOTING, INSTALL ALUMINUM TRANSITION STRIP AT TOP AND BOTTOM SEAMS AND AT CORNERS OF WALLS. 1 A5.0 34" MAX. B.O. REFLECTIVE SURFACE 40" MAX. SINK MIRRORPAPER TOWEL DISPENSER TOILET 48" MAX SEAT COVER DISPENSER 33" - 36" GRAB BAR BEHIND TOILET 27" MIN. SIDE GRAB BARS & DISPENSERS 39" - 41" 42" MIN. MAX. 12" 1 1/2" MIN (7" - 9") 8" DISPENSER MAX. 6" 18" MIN. 39" - 41" 16''-18'' 42'' MIN. 54'' MIN. DISPENSING SLOT M AX 4'-0'' T.O. 1" NAPKIN DISPOSAL 33" - 36" MIN 2'-0" MIN 1'-0" 2'-10" 1" OVERHANG 1'-6" 2'-6" 1" OVERHANG 1'-5"2'-9"2'-8" 1 3/8" FILLER PANEL LEVEL 1 0" 1 A5.2 5 A5.2 6 A5.29 A5.2 2'-0" 5'-8" 8'-0" REFRIGERATOR F.O.I.C. GC TO INSTALL WATER CONNECTION COUNTERTOPS AND BACKSPLASH, PL-1 PAINT GWB P-1 UPPER CASEWORK, PL-2 LOWER CASEWORK, PL-2 DISPOSAL SWITCH 3'-6" 3'-10" NEW OUTLET 8'-0" (E) WALL BASE TO REMAIN LEVEL 1 0" EXTEND WALL TO CEILING, PAINT TO MATCH EXISTING 8'-0" 2'-10" 6" 4'-0" ALUMINUM TRIM PL-3 ALUMINUM TRIM SH-1 RUN UP WALL 6'' BACKSPLASH AND SIDESPLASH, PL-1 PAPER TOWEL DISPENSER PAINT GWB P-1 LEVEL 1 0" 1'-5" MIRROR 24X36 SOAP DISPENSER SEAT COVER DISPENSER GRAB BARS 6" ALUMINUM TRIM 4'-0" ALUMINUM TRIM 2 A5.2 BACKSPLASH AND SIDESPLASH, PL-1 NEW LIGHT FIXTURE, W-1 5'-0" 2'-6" 1" FILLER PANEL 3'-0" 8'-0" 1 A5.2 PL-3 SH-1 RUN UP WALL 6'' CABINET WITH LOCKING DOORS, PL-2 PAINT GWB P-1 LEVEL 1 0" 6" 4'-0" ALUMINUM TRIM PL-3 ALUMINUM TRIM SH-1 RUN UP WALL 6'' GRAB BARS TOILET PAPER DISPENSER SANITARY NAPKIN DISPOSAL PAINT GWB P-1 LEVEL 1 0" 6" 4'-0" ALUMINUM TRIM PL-3 ALUMINUM TRIM SH-1 RUN UP WALL 6'' 8'-0" PAINT GWB P-1 LEVEL 1 0" LEVEL 1 0" WALL BASE B-1 4" V.I.F. 6'-7" ALIGN TOP OF WINDOW FRAME WITH (E) DOORS, GC TO V.I.F. PAINT GWB P-1 8'-0" 4'-0" 6'-11" PAINT TRIM TO MATCH EXISTING (E) DOOR TO BE REUSED REGISTERED ARCHITECT 9480 Michael Christopher Winnick STATE OF WASHINGTON ISSUE DATE: DRAWN BY: PROJECT MANAGER: SHEET NUMBER: REVISION SCHEDULE PROJECT NUMBER: SHEET NAME: ISSUE: 7983 LEARY WAY NE, REDMOND, WA 98052 (425) 881-7506 MAIL@DRIFTMIER.COM 6/ 2 / 2 0 2 5 4 : 4 1 : 1 5 P M TI M B E R L A N D B A N K Y E L M 10 1 E Y E L M A V E , Y E L M , W A 9 8 5 9 7 MW JP 06/02/2025 22419 A5.0 INTERIOR ELEVATIONS PERMIT SET SCALE N/AINT. ELEVATION NOTES 17 SCALE 1/2" = 1'-0"TYPICAL ELEVATION HEIGHTS 1 SCALE 1/2" = 1'-0"BREAK ROOM NORTH 15SCALE 1/2" = 1'-0"FINANCIAL AREA WEST.19 SCALE 1/2" = 1'-0"T1 SOUTH ELEVATION 3SCALE 1/2" = 1'-0"T1 EAST 7 SCALE 1/2" = 1'-0"T1 NORTH 4SCALE 1/2" = 1'-0"T1 WEST 8SCALE 1/2" = 1'-0"OPEN OFFICE WEST 12 NO. TYPE REVISION DATE TEMP. 5'-8" 8" PER SCHD. 8"1'-8"8" SOLID CORE WOOD DOOR WITH WINDOW (NOT USED) B PER SCHD. PER SCHD. SOLID CORE WOOD DOOR A PER SCHD. 3" 3" PER SCHD. 3" PER SCHD. SOLID CORE WOOD DOUBLE DOOR (NOT USED) C DOOR NOTES 1. FOR DOOR TYPE ELEVATIONS, SEE DETAIL 2. ALL GLASS IN DOORS TO BE SAFETY GLASS. 3. MAX. THRESHOLD TRANSITION TO BE 1/2" VERT. W/SLOPING FACE OR 1/4" MAX TYP. 15 A5.1 HARDWARE NOTES: 1. ALL NEW HARDWARE SHALL BE ADA COMPLIANT. GENERAL WALL NOTES: 1. USE WATER & MOLD RESISTANT GWB IN ALL WET AREAS. 2. TAPE & FINISH ALL GWB SURFACES. PAINT ALL GWB EXPOSED TO VIEW. 3. SEE REFLECTED CEILING PLAN FOR ACTUAL CEILING FINISHES. 4. ALL INSULATION MATERIALS SHALL BE INSTALLED ACCORDING TO THE MANUFACTURER'S INSTRUCTIONS TO ACHIEVE PROPER DENSITIES AND MAINTAIN CLEARANCES, TO THE MAXIMUM EXTENT POSSIBLE. 5. ALL CORNERS AND EDGES OF GWB ARE TO BE FINISHED WITH CORNER OR J BEADS. 6" WALL C1 SECT. PLAN 2x6 FRAMING 5/8" GWB FIN. CEILING PER PLANS 5/8" GWB ON BOTH SIDES EXTEND GWB BEYOND CEILING 6" ON ACT SIDE6" B.O. JOIST 2x6 FRAMING ACOUSTICAL INSULATION RUN INSULATION ABOVE ACT 2' FROM WALL INSULATION SECT. 3 5/8'' WALL PARTITION PLAN 2x4 FRAMING 5/8" GWB BOTH SIDES FIN. CEILING PER PLANS 5/8" GWB A1 RUN INSULATION ABOVE ACT 2' FROM WALL ACOUSTICAL INSULATION 6" B.O. JOIST 2x4 FRAMING INSULATION FLOORING TRANSITIONS OCCUR WHERE DIFFERENT TYPES OF FLOORING MEET AND WHERE DIFFERENT COLORS/TYPES OF THE SAME FLOORING MEET. CARPET TRANSITION, T-MOLDING CARPET SUBFLOOR LVT CARPET TO LVT CARPET 1 SUBFLOOR CARPET 2 CARPET TO CARPET W2W1 STOREFRONT SYSTEM INT. WOOD WINDOW 7'-9" 8'-0" 2" 3'-0" DOOR 17 A5.1 11 A5.1 18 A5.1 12 A5.1 19 A5.1 TEMP. TEMP. SILL HT. 4" MATCH (E) V.I.F. 6'-7" 4'-0" MATCH EXISTING HT. 6'-11" ALUMINUM STOREFRONT SYSTEM (E) WALL SEALANT ALUMINUM STOREFRONT SYSTEM (E) WALL SEALANT ALUMINUM STOREFRONT SYSTEM FINISHED FLOOR CONCRETE SLAB SEALANT SLAB/SUBSTRATE NEW WALLS: SHOT PIN SILL PLATE TO SLAB @ 48" O.C. 2X4 WOOD STUD SHIM, TYP. PAINTED WOOD TRIM, TYP. PAINT PT-5 3" GLAZING WOOD STUD, 2X4 FIN. FLOOR PAINTED WOOD TRIM, TYP. PAINT PT-5 GLAZING WOOD STUD BASE PLATE AND BLOCKING 3" 6" RUBBER BASE, B-3 SHIM REGISTERED ARCHITECT 9480 Michael Christopher Winnick STATE OF WASHINGTON ISSUE DATE: DRAWN BY: PROJECT MANAGER: SHEET NUMBER: REVISION SCHEDULE PROJECT NUMBER: SHEET NAME: ISSUE: 7983 LEARY WAY NE, REDMOND, WA 98052 (425) 881-7506 MAIL@DRIFTMIER.COM 6/ 2 / 2 0 2 5 4 : 4 1 : 1 6 P M TI M B E R L A N D B A N K Y E L M 10 1 E Y E L M A V E , Y E L M , W A 9 8 5 9 7 MW JP 06/02/2025 22419 A5.1 SCHEDULES & DETAILS PERMIT SET # LOCATION TYPE DOOR WIDTH DOOR HEIGHT DOOR THICKNESS DOOR MATERIAL DOOR FINISH FRAME MATERIAL FRAME FINISH HARDWARE NOTES 1 T1 A 3' - 0" 6' - 8" 1 3/4" WOOD MATCH EXISTING WOOD P-3 PRIVACY 2 BREAK ROOM EXISTI NG 3' - 0" 6' - 8" 1 3/4" EXISTING EXISTING EXISTING P-3 STOREROOM (E) DOOR RELOCATED 3 OPEN OFFICE B 3' - 0" 7' - 10" 1 3/4" WOOD MATCH EXISTING EXISTING DARK BRONZE STOREROOM SCALEDOOR SCHEDULE 1N/A SCALEINTERIOR MATERIAL SCHEDULE 4N/A SCALE N/ADOOR AND FRAME TYPES 9 SCALE 3/4" = 1'-0"WALL TYPES 3 LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION LOCATION LAMP WATTAGE QTY. TOTAL WATTS NOTES D-1 RECESSED DOWNLIGHT TOILET LED 14 1 14 L1 SURFACE MOUNTED LINEAR OPEN OFFICE, BREAK ROOM LED 37 5 185 W-1 LINEAR WALL MOUNT TOILET LED 22 1 22 SCALE N/AFLOORING TRANSITIONS 13 SCALELIGHT FIXTURE SCHEDULE 16N/A TOTAL INTERIOR LIGHTING: 7 221 MATERIAL SCHEDULE NOTES: 1. INTERIOR WALL AND CEILING FINISHES TO MEET ASTM E84 FLAME SPREAD RATINGS PER TABLE 803.13 INTERIOR MATERIAL SCHEDULE TAG DESCRIPTION MANUFACTURER COLOR/PATTERN NOTES B-1 RUBBER BASE JOHNSONITE 284 GANACHE MATCH EXISTING CPT-1 CARPET TILE INTERFACE - THE POND COLLECTION 6704 BERLIN PEAT P-1 INTERIOR PAINT SHERWIN WILLIAMS 6106 KILIM BEIGE P-2 INTERIOR PAINT SHERWIN WILLIAMS 6107 NOMADIC DESERT P-3 INTERIOR PAINT SHERWIN WILLIAMS 6126 NAJAVO WHITE PL-1 PLASTIC LAMINATE WILSONART 4588K-07 KALAHARI TOPAZ TOILET ROOM, COUNTERTOPS PL-2 PLASTIC LAMINATE WILSONART 7935K-07 SHAKER CHERRY CASEWORK PL-3 PLASTIC LAMINATE WILSONART 4794-60 WINDSWEPT TOILET ROOM, WET WALLS SH-1 SHEET FLOORING MANNINGTON ASSURANCE II, 16306 TOASTED SESAME TOILET ROOM, JANITOR'S ROOM WD-1 INTERIOR WOOD STAIN MATCH PL-2 AND APPLY CLEAR COAT ARCHITECT TO APROVE SAMPLES FOR EACH MATERIAL TYPE SCALE 1/4" = 1'-0"WINDOW TYPES 15 SCALE 3" = 1'-0"STOREFRONT HEAD 17 SCALE 3" = 1'-0"STOREFRONT JAMB 18 SCALE 3" = 1'-0"STOREFRONT SILL 19 SCALE 1 1/2" = 1'-0"WALL SILL PLATE DETAIL 14 SCALE 3" = 1'-0"INT. WOOD WINDOW JAMB 11 SCALE 3" = 1'-0"INT. WOOD WINDOW SILL 12 NO. TYPE REVISION DATE ADJUSTABLE SHELVES, MELAMINE FINISH (TYP.) PLASTIC LAMINATE, PL-2 WHITE MELAMINE FINISH FACE OF WALL BLOCKING3/4" CLEAR 1'-0" 3'-0" MOCKETT PULL 1 1/4" PLAM COUNTER TOP, SPLASH, & EDGES, PL-1 SIM. COUNTER @ LAV. SINK 1 1/2" X 1 1/2" X 1/4" TUBE STL WELD @ 90 DEGREE CORNER (LAG BOLT TO DBL. STD IN WALL), PROVIDE @ FREE END OF COUNTER NOTE: INSULATE HOT WATER & WASTE PIPING BELOW VANITY PER CODE. 1'-6" 4" 5" 1'-6" 5" 5" 5" 3" 2' - 1 0 " F R O M LA V . T O F . F . IF L A V . I S H I G H E R PLASTIC LAMINATE, PER INTERIOR ELEVATIONS, PL-2 PLASTIC LAMINATE TOP & SPLASH , PL-1 MELAMINE FINISH 1X4 WOOD BLOCKING TOP & BOTTOM RUBBER BASE, B-1 3" 4" 1'-10 1/2" 6" 1 1/2" 4" 2'-10" FALSE FRONT, PL-2 SINK REMOVABLE BACK AT SINK PLASTIC LAMINATE, PL-2 WHITE MELAMINE FINISH FACE OF WALL BLOCKING 3/4" CLEAR 1'-8" 2'-0" MOCKETT PULL 1 1/4" 3/4" ADJUSTABLE SHELF, MELAMINE FINISH BORING AND SHELF REST SYSTEM, TYP 1'-10" ADJUSTABLE SHELVES, MELAMINE FINISH (TYP.) PLASTIC LAMINATE, PER INTERIOR ELEVATIONS, PL-2 PLASTIC LAMINATE TOP & SPLASH, PL-1 MELAMINE FINISH 1X4 WOOD BLOCKING TOP & BOTTOM RUBBER BASE, B-1 3" 4" 1'-10 1/2" 6" 1 1/2"4" 2'-10" 2'-1" 1" 2'-0" 1'-8" 1/4'' HARDBOARD BACKING, MELAMINE FINISH REGISTERED ARCHITECT 9480 Michael Christopher Winnick STATE OF WASHINGTON ISSUE DATE: DRAWN BY: PROJECT MANAGER: SHEET NUMBER: REVISION SCHEDULE PROJECT NUMBER: SHEET NAME: ISSUE: 7983 LEARY WAY NE, REDMOND, WA 98052 (425) 881-7506 MAIL@DRIFTMIER.COM 6/ 2 / 2 0 2 5 4 : 4 1 : 1 6 P M TI M B E R L A N D B A N K Y E L M 10 1 E Y E L M A V E , Y E L M , W A 9 8 5 9 7 MW JP 06/02/2025 22419 A5.2 DETAILS PERMIT SET SCALE 1" = 1'-0"UPPER CABINET 1 SCALE 1" = 1'-0"LAVATORY SECTION 2SCALE 1" = 1'-0"BASE CABINET @ SINK 6 SCALE 1" = 1'-0"UPPER CABINET REF.5 SCALE 1" = 1'-0"BASE CABINET 9 NO. TYPE REVISION DATE