TK6786305 - SOW5
4
VICINITY MAP
406 Porter Way
Milton, WA 98354
CANNON COMPANIES
CONTACT: Sam Sartain
PHONE: (253) 363-7384
EMAIL: ssartain@teamcannon.com
POWER MR
1 -COVER SHEET
2 -GENERAL NOTES
3 -LEGEND
4-5 -CONSTRUCTION PLAN
NO
SCALE
SCOPE OF WORK
- POWER MAKE-READY (MAINTENANCE) AT 2 PSE POLES TO MEET
NESC REQUIREMENTS
N
S
EW
POLE COUNT =
TRANSMISSION =
DISTRIBUTION =
POLES THAT NEED PERMIT =
POLES THAT NEED MAKE READY =
POLE INFORMATION
2
0
2
2
2
SHEET INDEX
Client:
Project No.
Permit No.
Revisions:
Original
1
2
3
4
5
6
PM DRAFTER
Sheet Title:
DATE
Sheet No.
Designed by: Drawn by: Checked by:
of
Sheet Scale:
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
PSE
PUGET
SOUND
ENERGY
26-904 - TK6786305
T17N R1E S24
1500 W Yelm Ave, Yelm, WA 98597
TK6786305
--------
SS TH 6/6/25
COVER SHEET
SS TH AB
001 005
NO
SCALE
STANDARD
1. THE LOCATIONS OF UTILITIES SHOWN ON THE PLANS ARE APPROXIMATE. ALL UTILITY LOCATIONS SHALL BE VERIFIED PRIOR TO
CONSTRUCTION. THE CONTRACTOR, AT HIS OWN EXPENSE, SHALL MAKE EXCAVATIONS AND BORINGS AHEAD OF THE WORK, AS
NECESSARY, TO DETERMINE THE EXACT LOCATIONS OF UTILITIES AND UNDERGROUND STRUCTURES. IT IS UNDERSTOOD THAT
THERE WILL BE INTERFERING UTILITIES AND OTHER UNDERGROUND PIPES, DRAINS OR STRUCTURES ENCOUNTERED THAT ARE
NOT SHOWN OR AREAS SHOWN INCORRECTLY ON THE PLANS OR THAT HAVE NOT BEEN PREVIOUSLY DISCOVERED IN THE FIELD.
THE CONTRACTOR AGREES THIS IS A NORMAL AND USUAL OCCURRENCE IN THE CONSTRUCTION OF UNDERGROUND
IMPROVEMENTS. FURTHERMORE, CONTRACTORS UNDERSTAND AND AGREE THAT WORK IN SOME CASES PROPOSED PATH MAYBE
IN CLOSE PROXIMITY TO SAID UTILITIES AND UNDERGROUND PIPES, DRAINS AND STRUCTURES NOT SHOWN ON THE PLANS WHICH
MAY REQUIRE A CHANGE IN OPERATIONS AND MAY CAUSE SLOUGHING OF THE TRENCH, ADDITIONAL TRAFFIC CONTROL,
ADDITIONAL PAVEMENT AND BACKFILL COSTS AND TIME. THE CONTRACTOR AGREES THAT A REASONABLE NUMBER OF THESE
OCCURRENCES IS USUAL AND ORDINARY, AND ARE REFLECTED IN THE BID AND PLAN OF OPERATION. THE CONTRACTORS AGREES
TO PROVIDE FOR THESE CONFLICTS AND AGREES TO PROVIDE FOR A REASONABLE AMOUNT OF TIME FOR DESIGN CHANGES
AND/OR UTILITY RELOCATIONS DUE TO SAID CONFLICTS.
2. CALL THE UTILITIES UNDERGROUND LOCATION CENTER AT 811
3. INSPECTIONS - THE CONTRACTOR SHALL NOTIFY LOCAL JURISDICTIONS FOR REQUIRED INSPECTION SERVICES.
4. EXCESS WATER - SHOULD WATER BE ENCOUNTERED DURING CONSTRUCTION, IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO
DEWATER, AS PER LOCAL JURISDICTIONS STANDARD SPECIFICATIONS, BEFORE CONSTRUCTION CONTINUES.
5. NO SILT LADEN WATER IS TO BE DISCHARGED FROM THE SITE WITHOUT PASSING THROUGH AN EROSION CONTROL SYSTEM.
6. THE CONTRACTOR SHALL SCHEDULE AND CONTROL HIS/HER WORK SO AS TO COMPLY WITH ALL APPLICABLE ORDINANCES TO
PREVENT ANY HAZARDS TO PUBLIC SAFETY, HEALTH AND WELFARE.
7. ALL STREETS SHALL BE KEPT FREE OF DIRT AND DEBRIS ON A CONTINUOUS BASIS.
8. AN APPROVED COPY OF THESE PLANS WILL BE ON THE JOB SITE WHENEVER CONSTRUCTION IS IN PROGRESS.
9. THE CONTRACTOR SHALL BE SOLELY AND COMPLETELY RESPONSIBLE FOR THE CONDITIONS OF THE JOB SITE, INCLUDING SAFETY
OF ALL PERSONS AND PROPERTY DURING THE PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY
AND NOT BE LIMITED TO NORMAL WORKING HOURS.
10. PEDESTRIAN AND VEHICULAR ACCESS TO ADJACENT PROPERTIES SHALL BE MAINTAINED AT ALL TIMES EXCEPT WHERE PRIOR
WRITTEN APPROVAL FROM THE PROPERTY OWNER HAS BEEN OBTAINED.
11. BARRICADE OPEN DEPRESSIONS AND HOLES OCCURRING AS PART OF THIS WORK, AND POST WARNING LIGHTS ON ADJACENT
PROPERTIES WITH PUBLIC ACCESS. OPERATE WARNING LIGHTS DURING HOURS FROM DUSK TO DAWN EACH DAY AND AS
OTHERWISE REQUIRED.
12. PROTECT STRUCTURES, UTILITIES, PAVEMENTS, AND OTHER FACILITIES FROM DAMAGE CAUSED BY SETTLEMENT, LATERAL
MOVEMENT, UNDERMINING WASHOUT AND OTHER HAZARDS CREATED BY OPERATIONS UNDER THIS SECTION.
TRAFFIC CONTROL
1. THE CONTRACTOR IS ADVISED THAT ALL LANE CLOSURES SHALL BE KEPT TO A MINIMUM. LOCAL JURISDICTIONS WILL APPROVE
ONLY THOSE LANE AND ROADWAY CLOSURES DETERMINED TO BE NECESSARY FOR THE CONTRACTOR TO ACCOMPLISH A
SPECIFIC TASK. NO LANE OR ROADWAY CLOSURES WILL BE PERMITTED WITHOUT PRIOR APPROVALS.
2. THE CONTRACTOR SHALL KEEP ALL TRAFFIC LANES AND SHOULDERS CLEAR OF EQUIPMENT AND MATERIALS DURING
NON-WORKING HOURS. EQUIPMENT AND MATERIALS SHALL NOT BE STORED ON THE STREETS. THE CONTRACTOR'S EMPLOYEES
AND AGENTS SHALL NOT PARK PRIVATE VEHICLES ALONG THE ROADWAY OR MEDIAN.
SITE PREPARATION
1. SOD AND LAWN TO BE REMOVED SHALL BE CUT TO A NEAT VERTICAL LINE 6" MINIMUM BEYOND THE TRENCH LINE. SOD SHALL BE
EITHER REMOVED FROM THE SITE, OR CAREFULLY STOCKPILED FOR REUSE.
2. SAW CUT PAVEMENT TO A NEAT VERTICAL LINE 8" TO 12" MINIMUM BEYOND THE TRENCH LINE. REPLACE PAVEMENT WITH LIKE
MATERIAL (I.E., ASPHALT WITH ASPHALT, CONCRETE WITH CONCRETE).
3. EXCEPT AS NOTED HEREIN, ALL MATERIAL REMOVED SHALL BE TAKEN FROM THE SITE AND DISPOSED OF BY THE CONTRACTOR.
TRENCH EXCAVATION AND BACKFILL
1. TRENCH BACKFILL - WHERE MATERIAL EXCAVATED FROM TRENCHES IS UNSUITABLE FOR BACKFILL, THE CONTRACTOR SHALL
BACKFILL WITH BANK RUN GRAVEL OR MAY ELECT TO USE CDF IN LIEU OF THE COMPACTION/PROCTOR PROCESS. STONEWAY MIX
351 IS ACCEPTABLE IN ALL LOCATIONS. QUICK SETTING MIX 1004 IS ACCEPTABLE IN NON-TRAFFIC AREAS. MIX 1121 IS TO BE USED IN
TRAFFIC-BEARING LOCATIONS.
2. COMPACTION, WHEN NECESSARY, SHALL BE PERFORMED IN ACCORDANCE WITH LOCAL JURISDICTION REQUIREMENTS.
UTILITY DUCT
1. BURIED DUCT SHALL BE SCHEDULE 80 PVC OR EQUIVALENT, UNLESS NOTED OTHERWISE. MINIMUM CONDUIT COVER SHALL BE 36"
WITH A MINIMUM SLOPE OF 1/2 % TO VAULT.
2. THOROUGHLY CLEAN CONDUIT BEFORE USING OR LAYING. DURING CONSTRUCTION AND AFTER THE DUCT LINE IS COMPLETED,
PLUG ENDS OF CONDUITS TO PREVENT WATER WASHING INTO CONDUIT OR MANHOLES, TAKE PARTICULAR CARE TO KEEP
CONDUITS CLEAR OF CONCRETE, DIRT AND ANY OTHER SUBSTANCE DURING THE COURSE OF CONSTRUCTION.
3. AFTER DUCT PLACEMENT HAS BEEN COMPLETED, PROOF AND CLEAN DEBRIS FROM EACH DUCT, ITS ENTIRE LENGTH. INSTALL PULL
ROPE AND PLACE WATERTIGHT COMPRESSION PLUGS AT BOTH ENDS. ANY CONDUITS CONTAINING FIBER CABLE WILL REQUIRE
SIMPLEX COMPRESSION PLUGS SEALING THE CONDUITS AROUND THE CABLE.
4. OUTSIDE INNERDUCT SHALL BE 1-1/4" OPTIC-GUARD NON-METALLIC FLEXIBLE, IN COLOR SUCH AS RED OR ORANGE, WITH PULL
ROPES AND PLUGS. EXPOSED INNERDUCT INSIDE OF BUILDINGS SHALL BE PLENUM-RATED.
CEMENT CONCRETE PAVEMENT
1. ALL CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED ACCORDING TO THE STANDARD
SPECIFICATIONS OF EACH JURISDICTION.
ASPHALT CONCRETE PAVEMENT
1. ALL ASPHALT CONCRETE PAVEMENT REMOVED OR DAMAGED BY THIS WORK SHALL BE REPLACED WITH CLASS B ASPHALT
CONCRETE ACCORDING TO THE REQUIREMENTS OF EACH JURISDICTION.
GRAVEL AREAS
1. ALL GRAVEL AREAS DAMAGED OR REMOVED BY THIS WORK SHALL BE REPLACED WITH CRUSHED SURFACING TOP COURSE IN
ACCORDANCE WITH THE REQUIREMENTS OF EACH JURISDICTION.
SITE RESTORATION
1. ALL DISTURBED OR DAMAGED AREAS SHALL BE RESTORED TO A CONDITION EQUAL TO, OR BETTER THAN, THAT WHICH EXISTED
PRIOR TO PLACEMENT OF THE CONDUIT AND STRUCTURES.
2. VEGETATION REMOVED FOR THIS WORK SHALL BE REPLACED WITH IN-KIND PLANT MATERIAL AND SHALL BE PROPERLY PLANTED
AND WATERED IN TO ENSURE ITS SURVIVAL.
3. SITE RESTORATION SHALL INCLUDE REPLACING EXISTING CABLING AND PULL ROPES IN EXISTING CONDUITS AS THEY EXISTED
PRIOR TO CONSTRUCTION.
WATER QUALITY
1. CONSTRUCTION ACTIVITIES OCCURRING ADJACENT TO STORM DRAINAGE STRUCTURES SHALL COMPLY WITH THE STATE OF
WASHINGTON'S WATER QUALITY STANDARDS
2. THE CONTRACTOR SHALL LIMIT THE USE OF PETROLEUM PRODUCTS ON THE SITE.
DIRECTIONAL BORING
1. WHEN BORING ROADWAYS, INSTALL (1) 4" SCHEDULE 40 PVC CONDUIT WITH PULL ROPES AND PLUGS.
2. PROTECT EXISTING UTILITIES -- COORDINATE WITH LOCAL JURISDICTIONS TO POTHOLE AS REQUIRED TO LOCATE EXISTING
UTILITIES.
FIRE PROTECTION
1. ALL INSTALLED BACKBOARDS SHALL BE PAINTED WITH FIRE-RESISTANT PAINT.
2. ALL FIRE SEALED DUCT ENDS AND CORES SHALL BE 2 HOUR FIRE-RATED. ALL FIRE SEAL IN EXISTING LOCATIONS SHALL BE
REPAIRED OR REPLACED UPON DUCT OR CABLE PLACEMENT.
AERIAL INSTALLATION
1. ALL AERIAL CONSTRUCTION IS TO BE PERFORMED TO INDUSTRY ACCEPTABLE STANDARDS.
2. ALL NEW AERIAL (AND EXISTING) CABLE HEIGHTS OF ATTACHMENT TO BE DOCUMENTED AT TIME OF CONSTRUCTION.
3. 6.35 MM STRAND TO BE USED WITH STANDARD 1/4" POLE LINE HARDWARE UNLESS OTHERWISE SPECIFIED. BOND STRAND TO
POWER MAIN WHERE APPLICABLE.
4. ALL ANCHORS TO BE USED WILL BE 3/4" SCREW TYPE.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAINTAIN AND FOLLOW ALL NESC CODES ALONG WITH APPLICABLE LOCAL AND
REGIONAL GOVERNING AUTHORITIES. ANY DISCREPANCIES BETWEEN THESE AUTHORITIES AND OR THE CONSTRUCTION PERMITS
IS TO BE VALIDATED WITH THE DESIGNER OR ENGINEER PRIOR TO CONSTRUCTION.
Client:
Project No.
Permit No.
Revisions:
Original
1
2
3
4
5
6
PM DRAFTER
Sheet Title:
DATE
Sheet No.
Designed by: Drawn by: Checked by:
of
Sheet Scale:
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
PSE
PUGET
SOUND
ENERGY
26-904 - TK6786305
T17N R1E S24
1500 W Yelm Ave, Yelm, WA 98597
TK6786305
--------
SS TH 6/6/25
GENERAL NOTES
SS TH AB
002 005
NO
SCALE
V
NEW
V
TH
NEW
TH
CAB
NEW
CAB
DH
NEW
DH
P
NEW
P
LINE TYPES
FL FL
EOP EOP
ROW ROW
S/W S/W
D/W D/W
X X
U U U U U U U U
P P
PARCEL LINE
BUILDING OUTLINE
LANE LINE
CENTERLINE / STATION LINE
FOG LINE
EDGE OF PAVEMENT (EOP)
RIGHT OF WAY (ROW)
SIDEWALK (S/W)
DRIVEWAY (D/W)
FENCE
GUARDRAIL
CROSSWALK
RAILROAD
POWER
TS TS TRAFFIC SIGNAL
F/O F/O FIBER OPTIC
T T TELECOMMUNICATION
S S SEWER MAIN
SS SS SANITARY SEWER
D D DRAIN MAIN
DD DD DRAINAGE DITCH
G G GAS
OIL OIL OIL
STM STM STEAM
W W WATER
UNK UNK UNKNOWN UTILITY
TRAFFIC CONES
STRAW WATTLES
A A EXISTING AERIAL
A A NEW AERIAL
C C EXISTING/PROOF & PULL CONDUIT
PROPOSED CONDUIT
SYMBOLS
HATCH PATTERNS
CONCRETE ASPHALT
CONCRETE PANELS
LANDSCAPELIMITS OF RESTORATION
GRAVEL
BRICK/COBBLE
ROWIP ALLEY / TRAVEL LANE WZ
ROWIP PARKING / BIKE LANE WZ
ROWIP SIDEWALK WZ
OH OH OVERHEAD UTILITIES
#VAULT
(EXIST / NEW)
SIZE MAY VARY
MANHOLE
(EXIST / NEW)
DOGHOUSE
(EXIST / NEW)
TIGERHOUSE
(EXIST / NEW)
NODE CABINET
(EXIST / NEW)
PEDESTAL
(EXIST / NEW)
R R
UTILITY POLE
(EXIST / NEW)
UTILITY RISER
(EXIST / NEW)
200'
EXISTING SPLICE CASE
NEW SPLICE CASE
NEW MAT. STORAGE
NEW COAX TAP
UTILITY POTHOLE
POLE ANCHOR
/ DOWN GUY
CB CATCH BASIN
CATCH BASIN
W/ SOCK
CW CROSSWALK SIGNAL
SL STREET LIGHT
FH
FIRE HYDRANT
M WATER METER
V UTILITY VALVE
TREE
SHRUBBERY
N
S
EW
STREET SIGN
MAP COMPASS
339'FOOTAGE NOTE
LANE DIRECTION INDICATOR
BUS STOP LOCATION
MARK-UP NOTATIONS
#
#
PHOTO LOCATOR/ORIENTATION
CALLOUT
CONSTRUCTION NOTE CALLOUT
POLE # CALLOUT
STA 0+00 DISTANCE STATION
A
#
CROSS SECTION SYMBOL
CROSS SECTION NAME
CROSS SECTION SHEET #
#WORK
LOCATION PHOTO NOTE CALLOUT
#DISTANCE DIMENSION
ADA RAMP
CB
#VAULT # CALLOUT
MH MH
Client:
Project No.
Permit No.
Revisions:
Original
1
2
3
4
5
6
PM DRAFTER
Sheet Title:
DATE
Sheet No.
Designed by: Drawn by: Checked by:
of
Sheet Scale:
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
PSE
PUGET
SOUND
ENERGY
26-904 - TK6786305
T17N R1E S24
1500 W Yelm Ave, Yelm, WA 98597
TK6786305
--------
SS TH 6/6/25
LEGEND
SS TH AB
003 005
1120
1310
MO
U
N
T
A
I
N
V
I
E
W
R
D
S
E
R
O
W
R
O
W
R
O
W
RO
W
RO
W
RO
W
RO
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
R
O
W
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:
5 PSE
559686-147034
NEUTRAL 33 4 N N/A
SECONDARY DRIP LOOP 31 7 N N/A
STREET LIGHT 28 7 N N/A
STREET LIGHT DRIP LOOP 27 5 N N/A
CATV 25 0 N N/A
WAVE 23 10 N N/A
D
RE-TENSION SECONDARY TO P6 TO CREATE 26" MID-SPAN
CLEARANCE FROM CATV
W
Y
E
L
M
W
A
Y
W
Y
E
L
M
W
A
Y
0'25'50'
N
S
EW
Client:
Project No.
Permit No.
Revisions:
Original
1
2
3
4
5
6
PM DRAFTER
Sheet Title:
DATE
Sheet No.
Designed by: Drawn by: Checked by:
of
Sheet Scale:
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
PSE
PUGET
SOUND
ENERGY
26-904 - TK6786305
T17N R1E S24
1500 W Yelm Ave, Yelm, WA 98597
TK6786305
--------
SS TH 6/6/25
CONSTRUCTION PLAN
SS TH AB
004 005
9107
9105
9234
14908
14914
14920
14926
14934 14940 14946 14952 14958
14957
14951
14945
149391493314927
14921
1491514909
RO
W
RO
W
RO
W
RO
W
ROW
RO
W
RO
W RO
W
RO
W
RO
W
RO
W
RO
W
RO
W
OWNER:
POLE#:
- ATTACHMENTS - HEIGHT
CLASS/HT:
POLE TYPE:
- MAKE READY - VIOLATION
MID SPAN:
14 PSE
559920-147038
NEUTRAL 33 8 N N/A
SECONDARY DRIP LOOP 27 9 N N/A
CATV 22 6 N N/A
D
EXTEND SECONDARY RISER 40" ABOVE CATV
MO
U
N
T
A
I
N
V
I
E
W
R
D
S
E
91ST AVE SE
0'25'50'
N
S
EW
Client:
Project No.
Permit No.
Revisions:
Original
1
2
3
4
5
6
PM DRAFTER
Sheet Title:
DATE
Sheet No.
Designed by: Drawn by: Checked by:
of
Sheet Scale:
CANNON COMPANIES
SAFETY | QUALITY | INTEGRITY | TEAMWORK
Connecting The Future Since 1985
PSE
PUGET
SOUND
ENERGY
26-904 - TK6786305
T17N R1E S24
1500 W Yelm Ave, Yelm, WA 98597
TK6786305
--------
SS TH 6/6/25
CONSTRUCTION PLAN
SS TH AB
005 005