WSU_C32021_CypressWSU Code Compliance Calculator, WSEC 2021 Project Information Messages / Comments *RESULT=PASS Medium Dwelling Unit LGI Homes Plan Cypress Note: Review required for custom entries: - Wall (above grade) UA Reduction = 24.26, Proposed UA is better than baseline by 10.3% Contact Information Window area is 11% of floor area - Whole House Mechanical Ventilation Airflow Rate: 50 CFM with Run Time Percent of 100%, Balanced, Distributed Maximum allowable total measured duct leakage: 130 CFM25 ANALYSIS SET UP What code compliance pathway are you using? Project Building Type? Occupancy Type? Code Version? Classification:Medium Dwelling Unit -- 1623 sq. ft. Baseline Description: Code Baseline - Maximum baseline window area is 15% of floor area. About Your Selection:No exempt window or door areas - RESULTS - Comparison of Baseline and Proposed Design ** Component Performance, R occupancies U *Area UA Area UA Doors U =0.300 42 12.5 42 12.5 Overhead Glazing U =0.500 0 0.0 0 0.0 Vertical Glazing U =0.300 180 53.9 180 44.9 Flat/Vaulted Ceilings U =0.024 1,034 24.8 1,034 25.9 Wall (above grade) U =0.056 2,030 113.7 2,030 101.5 Floors over Crawlspace U =0.029 1,034 30.0 1,034 25.9 Slab on Grade F =0.540 0 0.0 0 0.0 Below Grade Wall U =N/A 0 0 0.0 Below Grade Slab F =N/A 0 0 0.0 * Values from Table R402.1.2 (Oct 2023) Baseline UA Total 234.9 Proposed UA Total 210.6 Required Credits 8.0 Proposed Credits 8.0 from Tables 406.2 and 406.3 UA Percent Reduction 10% UA Reduction 24.3 ** Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. Total Credits (406.2 & 406.3) 8.0 * Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ. Air source ducted Heat Pump w/ Min HSPF2 of 10 (HSPF of 11). If htg design temp is 23F or below,a cold climate variable capacity heat pump is required. Ducts/distribution system in conditioned space per R403.3.2 Electric resistance, hydronic, ductless and gas fired systems < 80% AFUE systems not permitted 1.0 0.5 Table R406.2 Energy Equalization Credits 3.0Variable Refrigerant Heat Pump or Air-to- Water Heat Pump Select Options Not Selected - Per Section R402.4.1.2 / 2.0 ACH50 / For R-2, 0.25 cfm per ft2 at 50 Pa. / HRV with min SHR eff of 0.65 per IRC Section M1505.3 or IMC Section 403.8 Table R406.3 Energy Credits Option No. 2 Air Leakage Control and Efficient Ventilation Efficient Building Envelope 3.1 -3.10 Energy Credits (406.3) High Efficiency HVAC Distribution System4 System No. 4 Option 2.1 Fuel Normalization Credits (406.2) 1 Option 3.6 5.0 Full Description For heating system using a heat pump that meets federal standards for the equipment listed in Table C403.3.2(2) or Table C403.3.2(9) OR Air to Water heat pump units that are configured to provide both heating and cooling and are rated in accordance with AHRI 550/590 High Efficiency HVAC Option 4.1 Energy Credits 3.11 Not SelectedHigh Efficiency HVAC: Smart Thermostat 0.0 - 0.250 0.025 0.050 0.025 Proposed Design Total UA Alternative, Whole Building Trade Off Analysis U Baseline New Construction R3 Single family dwellings and townhouses WSEC 2021 0.300 0.0 Brief Description of Selected Options* 1.0 Category Select System Type WSU_C32021_Cypress.xlsm 5/19/2025 1 WSU Code Compliance Calculator, WSEC 2021 Renewable Electric Energy kWh Energy Credits *Refer to WSEC 2015 Table R406.2 for complete option descriptions and requirements 0.0 Electric heat pump water heater meeting NEEA Tier 3. Compact Hot Water Distribution System Max volume between heat source and fixture is 16 Oz per section R403.5.2, on demand circ. Pump may be required. 0.0 5.0 7 Appliance Package Efficient Water Heating: Drain Heat Recovery Efficient Water Heating Efficient Water Heating: Compact Hot Water Distribution 5.1 5.3-5.8 5.2 6 2.0 Option 5.6 Option 5.2 0.5 0.0 Not Selected WSU_C32021_Cypress.xlsm 5/19/2025 2 WSU Code Compliance Calculator, WSEC 2021 THERMAL ENVELOPE DETAILS - Proposed Design Conditioned Floor Area, Proposed Design 1,623 sq. ft Classification Medium Dwelling Unit Exterior Doors Plan Component Door ID Description Ref. U Qt. Feet Inch Feet Inch Area UA Code Baseline, U=0.30 - 0.30 1 3 0 8 0 24 7.2 Code Baseline, U=0.30 - 0.30 1 2 8 6 8 18 5.3 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 0 0.0 Sum of Area and UA 42 12.5 0 0 Exterior Doors Area Weighted U 0.300 Overhead Glazing Plan Component Glazing ID Description U Feet Inch Feet Inch - - - - - 0.0 0 0 0 Overhead Glazing Area Weighted U Vertical Glazing Schedule Rows to Show 5 Plan Component Glazing ID Description U Feet Inch Feet Inch 1 U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 1 3 0 4 6 13.5 3.38 2 U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 1 6 0 6 10 41.0 10.25 3 U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 3 5 0 5 0 75.0 18.75 4 U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 5 2 0 2 0 20.0 5.00 5 U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 2 3 0 5 0 30.0 7.50 Sum of Area and UA 179.5 44.9 0 Vertical Glazing Area Weighted U 0.250 Vertical Glazing and Doors Area Weighted U 0.259 Flat/Vaulted Ceilings Plan Component Attic ID Description U R60 blown Attic STD baffled 10-7 0.025 1,034 25.9 1,034 25.9 0 Walls (Above Grade) Plan Component Wall ID Description Ref. U UA R23 BIBS 2x6W Custom 0.050 2,030 102 Refer to WSEC R402.1.5 U-factor Reference and Calculations 2,030 102 1 Width Ref. Ref. Height Notes Height Area Width Qt. Sum of Area and UA Qt. UAArea HeightWidth Sum of Area and UA Net Area Sum of Area and UA Ref. UA Area UA WSU_C32021_Cypress.xlsm 5/19/2025 3 WSU Code Compliance Calculator, WSEC 2021 Floor (over crawl or exterior) Plan Component Floor UA ID Description Ref. U R38 vented Joist (2021 1.2, 1,3; 2018 1.3-1.5)10-3 0.025 1,034 26 1,034 26 0 Slab on Grade (less than 2 feet below grade) Plan Component Slab ID Description Ref. F FP 0 0 0 Below Grade Walls and Slabs Plan Component Slab Wall Wall Wall Slab ID Description Depth Ref. U Area UA UA Sum of Area, Length and UA 0 0.0 0 0 0 Links to Download Forms, Checklists and Other Resources Compliance Certificate Instructions Insulation Certificate for Residential New Construction Duct Testing Affadavits Existing Construction New Construction Prescriptive Checklist for 2018 WSEC Alterations (Remodel) Worksheet EER SEER2 COP HSPF2 Converter https://www.adicotengineering.com/eer-seer2-cop-hspf2-kwton-converter Ventilation Requirements Conditioned Floor Area 1,623 sq. ft. Number of Bedrooms 3 Run-Time Percent in Each 4-Hour Segment 100% Is the system Balanced?Verify system meets definition of 'Balanced Whole-House Ventilation' Is the system Distributed?Verify system meets definition of 'Distributed Whole-House Ventilation' Ventilation Code Section IRC, Chapter 15 Whole House Mechanical Ventilation Airflow Rate 50 CFM HVAC Thermal Distribution System Download RS-33 (2018) Is this a hydronic heating system? Location of Ducts Location of Air Handler Is Duct Testing Required? Yes Maximum Duct Leakage: Maximum total measured duct leakage per square foot 0.08 CFM25 per sq. ft. Maximum allowable total measured duct leakage 130 CFM25 A maximum of 10 feet of return ducts and 5 feet of supply ducts are allowed to be located outside of the building thermal envelope, if insulated and sealed per R403.3.7. Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool: Nearest Weather Station Indoor Design Temperature 70 F Outdoor Design Temperature 24 F Design Temperature Difference (∆T)46 F Conditioned Floor Area, Proposed Design 1,623 ft2 Conditioned Volume 15,336 ft3 0.00 Leave blank to use default of 8.5 ft. ceiling height HVAC System Type Location of HVAC Distribution System Conditioned Space http://www.energy.wsu.edu/Documents/Duct%20Testing%20Standards%20_2018%20WSEC.pdf Conditioned Space https://betterbuiltnw.com/resources/hvac-sizing-tool Link Prescriptive Checklist Affidavit, Existing Affidavit, New Worksheet No Sum of Perimeter and FP Slab Perim Compliance Certificate Insulation Certificate Sum of Area and UA Distributed Balanced Slab Slab Perim Seattle: Sea-Tac AP Conditioned Space Area F Heat Pump WSU_C32021_Cypress.xlsm 5/19/2025 4 WSU Code Compliance Calculator, WSEC 2021 Sum of UA 211 Envelope Heat Load 9,688 Btu / Hour Sum of UA X ∆T Air Leakage Heat Load 7,619 Btu / Hour ((Volume X 0.6) X ∆T) X .018)) Building Design Heat Load 17,307 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 17,307 Btu / Hour For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1 For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 21,634 Btu / Hour Building and Duct Heat Loss X 1.25 for heat pumps 6.3 kW Building and Duct Heat Loss X 1.40 for all other systems WSU_C32021_Cypress.xlsm 5/19/2025 5