Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
25-064 Wing Stop TI - Fire Sprinkler Equipment Submittal 7-16
KNIGHT FIRE PROTECTION, INC. 9702 LATHROP INDUSTRIAL DR. SW OLYMPIA, WA 98512-9188 (360) 786-8606 FAX 786-8722 LICENSE NO. KNIGHFP044LK Fire Sprinkler System Equipment Submittal Wing-Stop TI 937 Yelm Ave. W, Suite B Yelm, WA 98597 KFP Job #25-064 KFP Job #12-113 Model F1FR56 UprightModel F1FR56 Pendent Model F1FR56 Horizontal Sidewall Model F1FR56 Vertical Sidewall Note: Not all versions of the product are shown. F1FR Series Sprinklers Summary Sprinkler Model K-Factor gpm/psi1/2 (lpm/bar1/2)Orientation Listings & Approvals Max. Working Pressure psi (bar) Sprinkler Identification Number (SIN) F1FR56 5.6 (80) Upright Intermediate Upright cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1425 Pendent cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Concealed Pendent cULus, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Horizontal Sidewall cULus, FM 175 (12) 250 (17) (cULus only)RA1435 Vertical Sidewall cULus, FM, LPCB, UKCA 175 (12)RA1485 Table A Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- tification Number (SIN), application, performance, and listings/ approval are not otherwise affected. Sprinklers with New frames will include the suffix “N” in the order. Features • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Reliable Model F1FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1FR series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. www.reliablesprinkler.com K-factor 5.6 (80) F1FR56 Series Quick Response Sprinklers Bulletin 074 January 2023 Model F1FR56 Pendent Sprinkler SIN RA1414 Technical Specifications Style: Pendent Recessed Pendent Concealed Pendent Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings(1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons Model F1 (cULus, LPCB, VdS, CE, WM) Model F2 (cULus, FM, LPCB, VdS, CE, WM) Model FP (cULus, VdS, CE, WM) Cover Plate Model CCP (cULus, VdS(2), CE(2)) Guards & Shields (New Frames)(3) F-1 Guard (FM) F-5 Guard/Shield Kit (FM) F-7 Guard (cULus) F-8 Guard/Shield Kit (cULus) S-1 Shield (cULus, FM) Guards & Shields (Legacy Frames)(3) C-1 Guard (FM) C-5 Guard/Shield Kit (FM) D-1 Guard (cULus, FM) D-4 Guard/Shield Kit (FM) D-5 Guard/Shield Kit (cULus, FM) S-1 Shield (cULus, FM) Sprinkler Wrenches Model W2 (pendent) Model W4 (recessed or concealed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(4) cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045, 0831-UKCA-CPR-5072 (CCP) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1FR56 Pendent Sprinkler Components and Dimensions Figure 2 F1FR_HALF_PEND_INT Deflector Glass Bulb (3 mm) Wrench Flat Threads 3 1/4" [83mm] 2 1/4" [57mm] 1" [25mm]Load Screw Cap/Seal Assembly Shown with Optional S-1 Water Shield (Ordered Separately) Note: Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 January 2023 Page 3 of 9 www.reliablesprinkler.com Models F1 & F1FR Pendent Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 2-7/8" (72 mm) Dia. 1-3/4" (44 mm) 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. Minimum Recess Maximum Recess 1" (25 mm) Face of Fitting to Face of Ceiling 1-1/8" (29 mm) at Max. Recess 3/8" (10 mm) at Min. Recess Models F1 & F1FR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1" (25 mm) 2-5/16" (59 mm) Dia. Minimum Recess Maximum Recess 1/2" (12 mm) 3-3/16" (78 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 2-7/8" (72 mm) Dia. 1-3/4" (44 mm) Minimum Recess Maximum Recess 1-1/4" (32 mm) Face of Fitting to Face of Ceiling 7/8" (22 mm) at Max. Recess 3/8" (10 mm) at Min. Recess 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. 2-1/2" (64 mm) Dia. Hole in Ceiling Models F1 & F1FR Pendent Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Reducing Fitting Reducing Fitting Reducing Fitting Note: Model FP recessed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Vented Cup Model F1FR56 CCP Conical Concealed Sprinkler 1/2" (13mm) Nominal Adjustment (Nominal Cover Plate Projection is 1" (25 mm)) 1" (25 mm) 2-5/16" (59 mm) Dia. Minimum Recess Maximum Recess 1/2" (12 mm) 3-5/16" (84 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 2-1/2" (64 mm) Dia. Hole in Ceiling F1_REC_PEND_CCP Reducing Fitting Note: Model CCP concealed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. Vented Cup Recessed and Concealed Installation: Pendent Sprinklers Figure 5 FP EscutcheonF1 Escutcheon (F2 Similar) CCP Cover Plate Bulletin 074 January 2023 Page 6 of 9 www.reliablesprinkler.com Installation Model F1FR Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats of the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N.m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Standard Finishes Special Application Finishes Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2)Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2) Bronze Brass Chrome Electroless Nickel PTFE(3)(4)Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5)Satin Chrome Satin Chrome White Polyester(3)White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F (93°C) maximum temperature rated sprinklers only. Finishes(1)Table B Maintenance Reliable Model F1FR series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Wrenches Model W2 (upright, pendent) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed, similar but with zinc finish)Model W4 (recessed, concealed pendent) Bulletin 074 January 2023 Page 8 of 9 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 6 2 3 Bulletin 074 January 2023 Page 9 of 9 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(1)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model J (New frame with guard installed) • Model JD (Legacy frame with guard installed) Notes: 1. 286°F (141°C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F3-56 Dry K5.6 (80 metric) Standard-Response, Standard Spray Sprinklers Bu l l e t i n 1 5 3 M a r c h 2 0 2 2 Bulletin 153 March 2022 Features 1. Available in the following configurations: • Pendent with standard escutcheon • Pendent with Model HB extended escutcheon • Pendent with Model FP recessed escutcheon • Pendent with Model F1 recessed escutcheon • Concealed Pendent with Model CCP cover plate • Horizontal Sidewall with Standard escutcheon • Horizontal Sidewall with Model HB extended escutch- eon • Horizontal Sidewall with Model FP recessed escutch- eon • Horizontal Sidewall with Model F1 recessed escutch- eon • Upright 2. Available with 1” NPT, ISO7-1R1, 3/4” NPT, or ISO7- 1R3/4 inlet fitting. 3. 3/4” NPT inlet fittings permit replacement of older 3/4” inlet dry sprinklers without changing to a larger sprinkler fitting. 4. Sprinklers, escutcheons, and cover plates are available in a wide variety of standard and special application fin- ishes. 5. cULus Listed as Corrosion Resistant when ordered with select finishes (see Finishes chart). 6. Available with cULus Listed 250 psi (17.2 bar) pressure rating for Dry Pendent and select HSW configurations. Other approvals are for 175 psi (12 bar). Product Description Model F3-56 Dry sprinklers are standard-response, standard coverage sprinklers with a nominal K-Factor of 5.6 (80 metric). Available in Dry Pendent, Dry Horizontal Sidewall , and Dry Up- right configurations, Model F3-56 Dry sprinklers all use a 5 mm glass bulb operating element. See the Temperature Ratings table in this Bulletin for available temperature ratings. Model F3- 56 Dry sprinklers are intended for installation on wet-pipe, dry- pipe, or preaction sprinkler systems in accordance with NFPA 13, FM Property Loss Prevention Data Sheets, and other ap- plicable installation standards. Model F3-56 Dry Pendent and Sidewall sprinklers are avail- able with a variety of escutcheon options as illustrated in Figs. 1 through 3 and Figs. 5 through 9. In addition, Model F3-56 Dry Pendent sprinklers are also available with the Model CCP conical concealed cover plate as illustrated in Fig. 4. Available sprinkler, escutcheon, and cover plate finishes are identified in the Finishes table in this Bulletin. The Model F1 escutcheon, Model FP escutcheon, and Model CCP cover plate are the only recessed escutcheons and cover plate listed for use with Model F3-56 Dry sprinklers; the use of any other recessed escutcheon or cover plate with Model F3-56 Dry sprinklers will void all guar- antees, warranties, listings and approvals. Concealed (See Fig. 4) Recessed FP Pendent (See Fig. 3) Recessed F1 Horizontal Sidewall (See Fig. 9) Horizontal Sidewall (See Fig. 6) Pendent (See Fig. 1) Recessed F1 Pendent (See Fig. 5) Recessed FP Horizontal Sidewall (See Fig. 8) Pendent / HB (See Fig. 2) Horizontal Sidewall / HB (See Fig. 7) Upright (See Fig. 10) Inlet fittings are available with 1” NPT, ISO 7-1R1, 3/4” NPT, or ISO7-1R3/4 threads. Sprinklers with 3/4” NPT and ISO7-1R3/4 inlet fittings are intended primarily for replacement of existing 3/4” or ISO7-1R3/4 inlet dry sprinklers, but may also be used in new installations. 2. See the Available Configurations, Listings, and Approvals table in this Bulletin for further information on Model F3-56 Dry sprinklers. Available Configurations, Listings, and Approvals Sprinkler Model Escutcheon or Cover Plate Available Length (See Figs. 1-9) Listings and Approvals(1) Inlet Threads Sprinkler Identification Number (SIN) F3-56 Dry Pendent Standard Escutcheon 2” to 36” (50 to 900 mm) cULus, NYC 3/4” NPT or ISO7-1R3/4 R5314 HB Extended Escutcheon 3-1/2” to 36” (90 to 900 mm) F1 Recessed Escutcheon FP Recessed Escutcheon CCP Cover Plate Standard Escutcheon 2” to 48” (50 to 1200 mm) cULus, FM, NYC, LPCB, CE(5), VdS (2) 1” NPT or ISO7-1R1 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon FP Recessed Escutcheon CCP Cover Plate F3-56 Dry Horizontal Sidewall Standard Escutcheon 2” to 48” (50 to 1200 mm) cULus(3), NYC(3)3/4” NPT or ISO7-1R3/4 R5334 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon FP Recessed Escutcheon Standard Escutcheon 2” to 48” (50 to 1200 mm) cULus(3), FM(4), NYC(3), LPCB, CE(5) 1” NPT or ISO7-1R1 HB Extended Escutcheon 3-1/2” to 48” (90 to 1200 mm) F1 Recessed Escutcheon FP Recessed Escutcheon F3-56 Dry Upright N/A 5” to 48” (127 to 1200 mm)cULus(3)1” NPT or ISO7-1R1 R5324 (1) For available temperature ratings and finishes see the Temperature Ratings and Finishes tables, respectively, in this Bulletin. (2) VdS approval is for Standard Escutcheon version only. (3) cULus Listing and NYC for Light Hazard and Ordinary Hazard only. (4) FM Approved for Light Hazard only. (5) CE 2831-CPR-S2006 Listing and Approval Agencies See the Available Configurations, Listings, and Approvals table in this Bulletin for listings and approvals applicable to each available configuration. 1. Listed by Underwriters Laboratories, Inc. and UL Certified for Canada (cULus) 2. Certified by FM Approvals (FM) 3. Permitted in New York City based on UL Listing per Local Law 33/2007 (NYC) 4. Loss Prevention Certification Board Approved (LPCB) 5. CE Listed 0832-CPD-2006 (CE) 6. VdS Schadenverhutung GmbH (VdS) Technical Data Nominal K-Factor: 5.6 gpm/psi1/2 (80 L/min/bar1/2) Sprinkler Listing or Approval Deflector to Ceiling Distance Maximum Working Pressure F3-56 Dry Pendent cULus, NYC See note below 250 psi (17.2 bar) FM, LPCB, CE, VdS See note below 175 psi (12 bar) F3-56 Dry Horizontal Sidewall cULus, NYC 4” to 6 “250 psi (17.2 bar) 4” to 12”175 psi (12 bar) FM, LPCB, CE See note below 175 psi (12 bar) F3-56 Dry Upright cULus See note below 175 psi (12 bar) 3. Temperature Classification Glass Bulb Color Sprinkler Temperature Rating Cover Plate Temperature Rating Maximum Ceiling Temperature Listings and Approvals(1) Ordinary Orange 135°F (57°C)135°F (57°C)100°F (38°C)cULus, FM, NYC, LPCB, CERed155°F (68°C) Intermediate Yellow 175°F (79°C)165°F (74°C)150°F (66°C)cULus, NYC Intermediate Green 200°F (93°C)165°F (74°C)150°F (66°C)cULus, FM, NYC, LPCB, CE High Blue 286°F (141°C)None 225°F (107°C)cULus, FM(2), NYC 165°F (74°C)150°F (66°C)cULus, NYC (1) For listed and approved sprinkler, escutcheon, and inlet configurations see the Available Configurations, Listings, and Approvals table in this Bulletin. (2) High temperature classification is FM Approved with Standard and Model HB escutcheons only. Note: Deflector distance to be in accordance with applicable NFPA, FM, or other agency requirements. Information is provided only when additional clarification is necessary. Finish Notes: 1. Finishes vary with type of trim selected. See table provided with each sprinkler detailed for finish combinations. 2. Paint or any other coating applied over the factory finish will void all approvals and warranties. 3. Other finishes and colors may be available on special order. Consult your Reliable sales representative for details. 4. For Standard Model HB, and Model F1 trims, both components of escutcheon are finished. 5. For Model FP and CCP trims, only the trim ring and cover plate are finished. The threaded sprinkler cup is unfinished. 4. COMDRYDET1-A System Fitting Inlet Fitting 1-5/8" [41mm] 3" [76mm] DIA. 2-1/8" [54mm] Dia. Hole in Ceiling 1/2" [12mm] Nominal Protrusion "A" Dimension Sprinkler Can Escutcheon Ceiling 1" [25mm] Escutcheon Adjustment 1/2" [12mm] Escutcheon Adjustment Nominal Escutcheon Position 1/2" [12mm] Note: The sprinkler can protrudes 1/2” (12mm) when escutcheon is in nominal position. Escutcheon adjustment provides -1/2” (12mm) to +1” (25mm) “A” dimension adjustment range. Fig. 1 Model F3-56 Dry Pendent Sprinkler with Standard Escutcheon (SIN R5314) “A” Dim.2” to 48” (51mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 2” to 36” (51mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Sprinkler Guard: Model C2 Finish Combinations: Standard Escutcheon Sprinkler Escutcheon(3)(4) Bronze Polished Stainless Bronze Laquered Brass Chrome Polished Stainless White Polyester(1)White Polyester Black Polyester(1)Black Polyester Custom Color Polyester(1)Custom Color Polyester Electroless Nickel PTFE(1)(5)Polished Stainless Wax(1)(2)Polished Stainless Lead(1)Polished Stainless Wax over Lead(1)(2)Polished Stainless Notes: 1. UL Listed as Corrosion Resistant. 2. Clear wax used on ordinary temperature rated sprinklers; brown wax used on intermediate temperature rated sprinklers. Brown wax may be used on high temperature rated sprinklers where the ambient temperature does not exceed 150°F (66°C). 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is 316 stainless steel unless noted. 5. FM Approved as Corrosion Resistant. Model F3-56 Dry Pendent Sprinkler with Model HB Extended Escutcheon (SIN R5314) “A” Dim.3½” to 48” (89mm to 1219mm) in 1/4” (6mm) increments for 1” connections or 3½” to 36” (89mm to 914mm) in 1/4” (6mm) increments for 3/4” connections Note: The sprinkler can protrudes 1¼” when escutcheon is in nominal position. Escutcheon adjustment provides -½” (-12.7mm) to +½” (+12.7mm) “A” dimension adjustment range. Fig. 2 5. Sprinkler Guard: Model C2 Finish Combinations: HB Escutcheon Sprinkler Escutcheon(3)(4) Bronze Chrome Chrome Chrome White Polyester(1)White Polyester Black Polyester(1)Black Polyester Custom Color Polyester(1)Custom Color Polyester Electroless Nickel PTFE(1)(5)Stainless Steel Wax(1)(2)Chrome Lead(1)Stainless Steel Wax over Lead(1)(2)Stainless Steel Notes: 1. UL Listed as Corrosion Resistant. 2. Clear wax used on ordinary temperature rated sprinklers; brown wax used on intermediate temperature rated sprinklers. Brown wax may be used on high temperature rated sprinklers where the ambient temperature does not exceed 150°F (66°C). 3. Escutcheons do not carry corrosion resistant listings. 4. Base material is cold rolled steel unless noted. 5. FM Approved as Corrosion Resistant. 13. Model F3-56 Dry Upright (SIN 5324) Order Dimensions 5” to 48” (127 mm to 1219 mm) Fig. 10 Finish Combinations: Upright Sprinkler Escutcheon Bronze NA Electroless Nickel PTFE(1)NA Notes: 1. UL Listed as Corrosion Resistant. 14. Fig. 11 Fig. 12 15. Fig. 14 - Model XLO2 Wrench Fig. 13 - Model F3R Wrench 16. Fig. 15 17. 18. Installation Instructions When used on wet pipe systems, Reliable Model F3-56 dry sprinklers may be installed in ductile or malleable cast iron threaded tees, or CPVC tees and adapters upon veri- fication that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 12). When used on dry pipe systems, Reliable Model F3- 56 dry pendent sprinklers MUST ONLY BE installed in the outlets of ductile or malleable cast iron threaded tees on horizontal pipe such that the inlet of the sprinkler protrudes above the bottom level of the pipe. When used on dry pipe systems, Reliable Model F3-56 dry sidewall and dry upright sprinklers may be installed in ductile or malleable cast iron threaded tees, or CPVC tees and adapters upon verification that the sprinkler inlet fitting does not interfere with the interior of the fitting (see Figure 12). DO NOT install Reliable dry sprinklers into elbows or couplings, welded outlets, mechanical tees, or gasket sealed CPVC fittings. Dry sprinklers connected to wet pipe systems must be installed as indicated in Figure 11 and as required by NFPA 13 with the Exposed Minimum Barrel Length located in a heated area. An orange protective clip is factory installed on the sprin- kler to protect the glass bulb thermal element from dam- age. The clip should remain in place during installation of the sprinkler and be removed when the sprinkler system is placed in service. Sprinklers with 3/4” NPT and ISO7-1R3/4 inlets are supplied with a protective cap on the inlet that must be removed before installation. Use the following steps for installation: 1. Cut a hole in the wall or ceiling directly in-line with the outlet of the fitting. See the Installation Data table for the recommended hole diameter based on the escutcheon or cover plate option selected. 2. Apply pipe joint compound or PTFE tape to the male threads of the sprinkler’s inlet fitting. 3. Install the sprinkler in the fitting using the installation wrench specified in the Installation Data table. The Model F3R wrenches are designed to be inserted into the groves in the sprinkler’s wrench boss as shown in Fig. 13. The Model XLO2 wrench is designed to fit into the cup and engage the wrench boss as shown in Fig. 14. Do NOT wrench any part of the sprinkler assembly other than the wrench boss. When inserting or removing the wrench from the sprinkler, care should be taken to prevent damage to the sprinkler. The sprinkler is then tightened into the pipe fitting to achieve a leak free con- nection. The recommended minimum to maximum in- stallation torque is 22 - 30 lb-ft (30 – 40 N-m) for 1” NPT and ISO7-1R1 sprinklers, and 14 - 20 lb-ft (19 – 27 N-m) for 3/4” NPT and ISO7-1R3/4 sprinklers. 3a. Alternatively, where access to the outer tube of the sprinkler is available, the Model F3-56 Dry sprin- kler may be installed using a pipe wrench. The pipe wrench shall only be permitted to interface with the galvanized steel outer tube portion of the sprinkler (Item #8 in Fig. 15). Do NOT wrench any other por- tion of the sprinkler assembly. A pipe wrench can in- stall the sprinkler into the fitting with a large amount of torque; consideration should be given to the need for future removal of the sprinkler because the instal- lation torque will have to be matched or exceeded to remove the sprinkler. The recommended minimum to maximum installation torque is 22 - 30 lb-ft (30 – 40 N-m) for 1” NPT and ISO7-1R1 sprinklers, and 14 - 20 lb-ft (19 – 27 N-m) for 3/4” NPT and ISO7-1R3/4 sprinklers. 4. Standard and Model HB escutcheons can be installed by slipping the escutcheon over the can until the es - cutcheon is seated against the ceiling or wall. Model F1 escutcheons are installed by pressing the escutcheon onto the collar until the escutcheon is seated against the ceiling or wall. The Model FP escutcheon is installed by pressing or threading the escutcheon into the cup by hand; the escutcheon can be tightened against the ceiling or wall by turning the escutcheon in a clockwise direction and removed by turning the escutcheon in a counter-clockwise direction. To install the Model CCP cover plate, first remove the protective clip. Install the Model CCP cover plate on the sprinkler by pressing or threading the cover plate into the cup by hand; the cov- er plate can be tightened against the ceiling by turning the cover plate in a clockwise direction and removed by turning the cover plate in a counter-clockwise direction. Note: Model F3 dry sprinklers are provided with orange bulb protectors to minimize bulb damage during shipping, handling, and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINKLER SYSTEM IS PLACED IN SERVICE FOR FIRE PRO - TECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PRO - TECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. 3. Inlet Threads: [1” NPT][ISO7-1R1][3/4” NPT][ISO7- 1R3/4] 4. Inlet Fitting: [Long – Standard Inlet Fitting][Short “PL” – Wet Pipe Systems only] 5. Sprinkler Temperature Rating: See Temperature Ratings table 6. Sprinkler Finish: See Finish Combinations Table 7. Escutcheon/Cover Plate Finish: See See Finish Combinations Table 8. Length: *For dry pendents and dry sidewalls: “A” Dimension is from face of tee to face of finished ceiling or wall in 1/4” (6mm) increments. See Fig. 1 through Fig. 9. *For dry uprights: Order dimension is from face of tee to top of deflector in 1/4” (6mm) increments. See Fig. 10. Notes: 1. For Dry Upright, customer is responsible for determining the correct deflector distance from structure above. 2. Length is based on normally gauged pipe thread “make- up” of .600” (15mm) per ANSI B2.1 (approximately 7-1/2 threads). Installation Wrench Model F3R Sprinkler Wrench (Standard and HB escutcheons) Model XLO2 Sprinkler Wrench (FP Recessed and CCP Concealed) Reliable Automatic Sprinkler Co., Inc. (800) 431-1588 Sales Offices (800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Manufactured by Recycled Paper Revision lines indicate updated or new data. EG. Printed in U.S.A. 03/22 P/N 9999970146 The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Installation Data Sprinkler Model Escutcheon or Cover Plate Suggested Hole Diameter in Wall or Ceiling Installation Wrench Required Centerline of Sprinkler Tube/Inlet to Finished Ceiling Vertical Dimension* F3-56 Dry Pendent Standard Escutcheon 2-1/8” (54 mm)F3R Not Applicable HB Extended Escutcheon 2-1/2” (64 mm)F3R F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 FP Recessed Escutcheon 2-1/2” (64 mm)XLO2CCP Cover Plate F3-56 Dry Horizontal Sidewall Standard Escutcheon 2-1/8” (54 mm)F3R 4-5/8” to 12-5/8” (118 mm to 321 mm)HB Extended Escutcheon 2-1/2” (64 mm)F3R F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 cULus, NYC 4-5/8” to 6-5/8” (118 mm to 168 mm)FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 F1 Recessed Escutcheon 2-1/4” (57 mm)XLO2 FM, LPCB, CE 4-5/8” to 12-5/8” (118 mm to 321 mm)FP Recessed Escutcheon 2-1/2” (64 mm)XLO2 F3-56 Dry Upright N/A 1-1/2” (38mm)F3R Not Applicable *Note: Based on 5/8” (16 mm) centerline of sprinkler tube/inlet to defector vertical distance. Maintenance The Model F3-56 Dry Sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25. Do not remove the factory applied thermally sensitive wax fillet between the bulb supporting cup and the wrenching boss. Do not replace this wax with a substitute substance. An Alternate substance may interfere with proper operation of the sprinkler. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gently vacuuming. Replace any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to sprinklers that would cause improper operation or non-operation. Ordering Information Specify: 1. Sprinkler: [Model F3-56 Dry Pendent SIN R5314][Model F3-56 Dry Horizontal Sidewall SIN R5334] [Model F3-56 Dry Upright SIN R5324] 2. Escutcheon/Cover Plate: [None][Standard escutcheon] [Model HB extended escutcheon][Model F1 recessed escutcheon][Model FP recessed escutcheon][Model CCP cover plate – pendent only] victaulic.com 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. ALWAYS REFER TO ANY NOTIFICATIONS AT THE END OF THIS DOCUMENT REGARDING PRODUCT INSTALLATION, MAINTENANCE OR SUPPORT. Series AH2 Series AH2-CC 1.0 PRODUCT DESCRIPTION Available Sizes by Component • Series AH2 Braided Hose: 31, 36, 48, 60, 72"/790, 914, 1219, 1525, 1830 mm. Note: length includes adapter nipple and 5.75"/140 mm straight reducer. • Series AH2-CC Braided Hose: 31, 36, 48, 60, 72"/790, 914, 1219, 1525, 1830 mm. Note: length includes captured coupling and 5.75"/140 mm straight reducer. • Sprinkler Reducers: ½" and ¾"/15 and 20 mm sprinkler connections and 5.75, 9, 13"/140, 230, 330 mm straight lengths and short, long 90º elbows. Note: The short 90° elbow is typically used with concealed sprinklers while the long 90º elbow is typically used in the installation of recessed pendent sprinklers. Low Profile long, and short 90° elbows for use with Style AB11 Bracket. • Inlet Connections: • 1"/25 mm Grooved IGS • 1"/25 mm NPT or BSPT adapter nipples for attaching to pipe and fittings outlined in NFPA standards. • ¾"/20 mm NPT or BSPT adapter nipples available for VdS. • 1 ¼"/ 32mm BSPT adapter nipples available for LPCB. • Brackets: • Style AB1 for suspended and hard-lid ceilings, allows installation before most ceiling tiles in place • Style AB2 for suspended and hard-lid ceilings, allows for vertical sprinkler adjustment, and installation before most ceiling tiles in place • Style AB3 for surface mount applications, wood, metal and block walls • Style AB4 for hard-lid ceilings with hat furring channel grid systems, allows for vertical sprinkler adjustment • Style AB5 for hard-lid ceilings, allows for vertical sprinkler adjustment • Style AB7 for suspended and hard-lid ceilings • Style AB7 Adjustable for suspended and hard-lid ceilings • Style AB8 for hard-lid ceilings with CD 60/27 profile metal studs (regionally available) • Style AB9 for hard-lid ceilings with hat furring channel grid systems • Style AB10 for Armstrong® TechZone™ ceilings • Style AB11 for lay-in panel suspended t-grid ceilings or drywall suspended t-grid ceilings, allows for low profile installations (use only with 90° low profile elbows) Victaulic® Vic-Flex™ Sprinkler Fittings Series AH2 and AH2-CC Braided Flexible Hoses 10.85 1 System No.Location Submitted By Date Spec Section Paragraph Approved Date 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 2 victaulic.com 1.0 PRODUCT DESCRIPTION (Continued) Maximum Working Temperature • 225°F/107°C Maximum Working Pressure • 200 psi/1375 kPa (FM Approval) • 175 psi/1206 kPa (cULus Listed) • 1600 kPa/232 psi (VdS/LPCB Approved) Connections • To adapter nipple (inlet) via • 1"/25.4 mm Grooved IGS • 1"/25.4 mm NPT or BSPT male thread • ¾"/20 mm BSPT male thread (VdS only) • 1 ¼"/32 mm BSPT male thread (LPCB only) • To sprinkler head (outlet) via ½" or ¾"/15 mm or 20 mm Minimum Bend Radius • 7"/178 mm (FM Approval) • 2"/51 mm (cULus Listed) • 3"/76.2 mm (VdS/LPCB Approved) Maximum Allowable Sprinkler K-Factors • FM (½"/15mm reducer) K5.6/8,1 (S.I.), (¾"/20mm reducer) K14.0/20,2 (S.I.) • cULus (½"/15mm reducer) K8.0/11,5 (S.I.), (¾"/20mm reducer) K14.0/20,2 (S.I.) • VdS/LPCB (½"/15mm reducer) K5.6/8,1 (S.I.), (¾"/20mm reducer) K8.0/11,5 (S.I.) 2.0 CERTIFICATION/LISTINGS 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 3 victaulic.com 3.0 SPECIFICATIONS – MATERIAL Series AH2 • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated • Low Profile Elbows: Stainless Steel Brackets: Carbon Steel, Zinc-Plated Series AH2-CC • Flexible Hose: 300-series Stainless Steel • Collar/Weld Fitting: 300-series Stainless Steel • Gasket Seal: Victaulic EPDM • Isolation Ring: Nylon • Nut and Nipple: Carbon Steel, Zinc Plated • Reducer (½"/15 mm or ¾"/20 mm): Carbon Steel, Zinc-Plated • Housing: Ductile iron conforming to ASTM A 536, Grade 65-45-12. Ductile iron conforming to ASTM A 395, Grade 65-45-15, is available upon special request. Coupling Housing Coating: • Orange enamel (North America, Asia Pacific). • Red enamel (Europe). • Hot dipped galvanized. Gasket:1 • Grade “E” EPDM (Type A) FireLock EZ products have been Listed by Underwriters Laboratories Inc., Underwriters Laboratories of Canada Limited, and Approved by Factory Mutual Research for wet and dry (oil free air) sprinkler services within the rated working pressure. 1 Services listed are General Service Guidelines only. It should be noted that there are services for which these gaskets are not compatible. Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. • Bolts/Nut: Zinc electroplated carbon steel, trackhead meeting the physical and chemical requirements of ASTM A 449 and physical requirements of ASTM A 183. • Linkage: CrMo Alloy Steel zinc electroplated per ASTM B633 Zn/Fe 5, Type III Finish 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 4 victaulic.com 4.0 DIMENSIONS Product Details - Series AH2 Braided Hose B 371 2 4685 A Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Adapter Nipple 6 Braid 7 Collar/Weld Fitting 8 Sleeve Hose Length Dimensions Hose Length A B inches mm inches mm inches mm 31/790 25.3/641 31/790 36/915 31.3/794 36/915 48/1219 42.3/1073 48/1220 60/1525 54.3/1378 60/1525 72/1830 66.3/1683 72/1830 Series AH2-CC Braided Hose Hose Length A B inches mm inches mm inches mm 31/790 24.5/622 29.8/757 36/915 29.5/749 34.8/884 48/1219 41.5/1054 46.8/1189 60/1525 53.5/1359 58.8/1494 72/1830 65.5/1664 70.8/1798 BA 3712 468 5 Item Description 1 Flexible Hose 2 Isolation Ring 3 Gasket 4 Nut 5 Captured Coupling 6 Braid 7 Collar/Weld Fitting 8 Sleeve 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5 victaulic.com 4.0 DIMENSIONS (C ontinued) Standard Reducer 1234 5.75"/140 mm straight reducer Optional Reducers 9.0"/229 mm straight reducer 13.0"/330 mm straight reducer 2.62"/ 66.5 mm 4.83"/ 122.7 mm 6.57"/ 166.9 mm 2.62"/ 66.5 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. • FM/VdS Approved only. 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 6 victaulic.com 4.1 DIMENSIONS VicFlex Brackets Style AB1 • Suspended Ceilings • Hard-Lid Ceilings (FM Only) Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented Center Bracket 3 End Bracket *Both sizes FM/VdS/LPCB approved, cULus listed Style AB2 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket *Both sizes FM/VdS/LPCB approved, cULus listed Style AB3 • Surface Mount Applications • FM Approved 3 2 1 3 3 2 1 3 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 7 victaulic.com 4.2 DIMENSIONS VicFlex Brackets Style AB4 • Hard-Lid Ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket for Hat Furring Channel *Both sizes FM/VdS approved, cULus listed Style AB5 • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket *Both sizes FM/VdS approved, cULus listed Style AB7 • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket *Both sizes FM/VdS approved. Style AB7 Adjustable • Suspended Ceilings • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket (adjustable) *Both sizes FM/VdS approved. 3 2 1 3 3 2 1 3 3 2 1 3 3 2 1 3 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 8 victaulic.com 4.3 DIMENSIONS VicFlex Brackets Style AB8 • Hard-Lid Ceilings Item Description 1 700 mm or 1400 mm Square Bar* 2 Patented Vertically Adjustable Center Bracket 3 End Bracket *Both sizes FM/VdS approved. Style AB9 • Hard-Lid ceilings with Hat furring channel grid system Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket for Hat Furring Channel *Both sizes FM/VdS approved. Style AB10 • Suspended ceilings • Armstrong® TechZone™ Item Description 1 6"/152 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket *FM/VdS approved, cULus listed. 3 2 1 3 3 2 1 3 3 2 1 3 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 9 victaulic.com 4.3 DIMENSIONS (C ontinued) VicFlex Brackets Style AB11 • Suspended ceilings • Hard-Lid Ceilings Item Description 1 24"/610 mm or 48"/1219 mm Square Bar* 2 Patented 1-Bee2® Center Bracket 3 End Bracket *FM/VdS approved, cULus listed. Low Profile 2.84"/ 72 mm 1.4"/ 36 mm 1.4"/ 36 mm 4.59"/ 116 mm Short 90° elbow reducer Long 90° elbow reducer NOTE • The Short 90° elbow reducer is typically used with concealed sprinklers while the longer 90 elbow is typically used in the installation of recessed pendent sprinklers. 3 2 1 3 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 10 victaulic.com 4.4 DIMENSIONS CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB1 Bracket Suspended Ceiling Grid with Recessed Sprinkler Suspended Ceiling Grid with Concealed Sprinkler V2707 MAX. EXTENSION R See chart A See Chart V2707 ¾"/19 mm MAX. RECESS 4.4"/ 113 mm 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on Center /"/16 mm Typical ceiling tile See note Finished ceiling face Bracket assembly Style AB1 2/"/60 mm max. hole 2"/51 mm min. hole R See chart A See Chart V3802 ½"/12.7 MM MAX. RECESS V3802 MAX. EXTENSION 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on Center /"/15.9 mm Typical ceiling tile See note Finished ceiling face 2/"/68.3 mm max. hole 2/"/60.3 mm min. hole Bracket Assembly Style AB1 4.4"/113 mm V2707 ¾"/19mm Max. Recess V3802 ½"/12.7mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.10.8 273 11.8 299 12.8 324 13.8 349 14.8 375 15.8 400 A Min.10.1 269 11.1 281 12.1 307 13.1 333 14.1 358 15.1 383 Suspended Ceiling Grid with Recessed Sprinkler with 90° Elbow (Long) Suspended Ceiling Grid with Concealed Sprinkler with 90° Elbow (Short) A See Chart 4.4"/ 113 mm 1.7"/43 mm Typical ceiling grid 24"/610 mm or 48"/1219 mm on Center /"/16 mm Typical ceiling tile See note Finished ceiling face Bracket assembly Style AB1 V2707 MAX. EXTENSIONV2707 ¾" /19 mm MAX. RECESS 2/"/60 mm max. hole 2"/51 mm min. hole See note Finishedceiling face Bracket AssemblyStyle AB1 24"/610 mm or 48"/1219 mm on Center 2/"/68 mmmax. hole 2/"/60 mm min. holeASee Chart /"/16 mm Typical ceiling tile V3802 MAX. EXTENSIONV3802 ½"/12.7 mm MAX. RECESS 4.4"/ 113 mm 1.7"/43 mm Typical ceiling grid V2707 ¾"/19mm Max. Recess V3802 ½"/12.7mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm A Min.8.0 200 A Min.5.8 147 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 11 victaulic.com 4.4 DIMENSIONS (Continued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB2 Bracket Hard-lid Ceiling with Concealed Sprinkler Hard-lid Ceiling with Recessed Sprinkler V3802 ½"/13 mm MAX. RECESS V3802 MAX. EXTENSION ASee chart Finished ceiling face 2¾"/68 mmmax. hole 2 ⁄"/59 mmmin. hole 3.5"/89 mm 16"/406 mm Stud C/C 1.8"/45 mm2" × 4" Stud Bracket assemblyStyle AB2#10 Screw RSee chart A See chart Finished ceiling face 2⁄"/60 mmmax. hole 2"/51 mmmin. hole3.5"/ 89 mm 16"/406 mm Stud C/C 1.8"/ 45 mm2" × 4" Stud Bracket assemblyStyle AB2#10 Screw V2707 MAX. EXTENSION R See chart V2707 ¾"/19 mm MAX. RECESS V3802 ½"/12.7mm Max. Recess V2707 ¾"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.7.6 193 8.6 218 9.6 244 10.6 269 11.6 295 12.6 320 A Min.6.1 155 7.1 180 8.1 206 9.1 231 10.1 256 11.1 282 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. Hard-lid Ceiling Grid with Concealed Sprinkler with 90° Elbow (Short) Hard-lid Ceiling with Recessed Sprinkler with 90° Elbow (Long) A See chart Finished ceiling face 2⁄"/60 mm max. hole 2"/51 mm min. hole3.5"/89 mm 16"/406 mm Stud C/C 1.8"/ 45 mm2" × 4" Stud Bracket assembly Style AB2#10 Screw V2707 MAX. EXTENSIONV2707 ¾"/19 mm MAX. RECESS ASee chart Finished ceiling face 2¾"/68 mm max. hole 2 ⁄"/59 mmmin. hole 3.5"/ 89 mm 16"/406 mm Stud C/C 1.8"/45 mm V3802 ½"/13 mm MAX. RECESS 2" × 4" Stud Bracket assemblyStyle AB2#10 Screw V3802 MAX. EXTENSION V3802 ½"/12.7mm Max. Recess V2707 ¾"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm A Min.5.0 127 A Min.3.6 91 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 12 victaulic.com 4.5 DIMENSIONS CLEARANCES WITHIN SIDEWALL Series AH2 Braided Hose and Style AB2 Bracket Horizontal Sidewall Sprinkler Horizontal Sidewall Sprinkler with 90° Elbow (Long) ASee chart Finished ceiling face 2⁄"/60 mm max. hole 2"/51 mm min. hole3.5"/ 89 mm 16"/406 mm Stud C/C 1.8"/ 45 mm2" × 4" Stud Bracket assembly Style AB2#10 Screw V2709 MAX. EXTENSION R See chart V2709 ¾"/19 mm MAX. RECESS A See chart Finished ceiling face 2⁄"/60 mm max. hole 2"/51 mm min. hole3.5"/ 89 mm 16"/406 mm Stud C/C 1.8"/ 45 mm2" × 4" Stud Bracket assembly Style AB2#10 Screw V2709 ¾"/19 mm MAX. RECESS V2709 MAX. EXTENSION V2707 ¾"/19mm Max. Recess V2707 ¾"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.3.6 91 A Min.6.1 155 7.1 180 8.1 206 9.1 231 10.1 256 11.1 282 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 13 victaulic.com 4.6 DIMENSIONS CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB4 Bracket Hat Furring Channel Grid with Recessed Sprinkler R See chart A See Chart V2707 ¾"/19.1 MM MAX. RECESS V2707 MAX. EXTENSION /"/23 mm Typical ceiling grid Typical 16"/406 mm – 24"/610 mm on Center /"/15.9 mmTypical ceiling tileSee note Finished ceiling face 2/"/60 mm max. hole 2"/51 mmmin. hole V2707 ¾"/19mm Max. Recess Hose Clearance Chart Dimension inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.10.3 262 11.3 287 12.3 313 13.3 338 14.3 363.5 15.3 389 Hat Furring Channel Grid with Recessed Sprinkler with 90° Elbow (Long) Hat Furring Channel Grid with Concealed Sprinkler with 90° Elbow (Short) A See Chart /"/23 mm Typical ceiling gridTypical 16"/406 mm – 24"/610 mm on Center /"/16 mm Typical ceiling tile See note Finished ceiling face V2707 ¾"/19.1 MM MAX. RECESS V2707 MAX. EXTENSION 2/"/60 mm max. hole 2"/51 mmmin. hole See Note V3802 MAX. EXTENSIONV3802 ½"/12.7 mm MAX. RECESS Finishedceiling face 16"/406 mm – 24"/610 mm on Center A See Chart /"/23 mm Typical ceiling grid 2/"/60 mm max. hole 2"/51 mm min. hole /"/16 mm Typical ceilingtile V2707 ¾"/19mm Max. Recess V2707 ¾"/19mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm A Min.8 200 A Min.5.9 149 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 14 victaulic.com 4.6 DIMENSIONS (C ontinued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB5 Bracket Hard-lid Ceiling with Recessed Sprinkler A See chart Finished ceiling face 2 ⁄"/60 mm max. hole /"/16 mm Typ. Drywall 2"/51 mm min. hole3.5"/89 mm 16"/406 mm Stud C/C 2.3"/ 57 mm V2707 ¾"/19 mm MAX. RECESS 2" × 4" Stud Bracket assembly Style AB5#10 Screw V2707 MAX. EXTENSION R See chart A See chart Finished ceiling face 2¾"/68 mmmax. hole /"/16 mmTyp. Drywall 2 ⁄"/59 mm min. hole 3.5"/ 89 mm 16"/406 mm Stud C/C 2.3"/57 mm V3802 ½"/13 mm MAX. RECESS 2" × 4" Stud Bracket assembly Style AB5#10 Screw V3802 MAX. EXTENSION R See chart V2707 ¾"/19mm Max. Recess V3802 ½"/13mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.6.1 155 7.1 180 8.1 206 9.1 231 10.1 256 11.1 282 A Min.7.6 193 8.6 218 9.6 244 10.6 269 11.6 295 12.6 320 Recessed Pendent with 90° Elbow (Long)Hard-lid Ceiling with Concealed Pendent with 90° Elbow (Short) A See chart 2 ⁄"/60 mmmax. hole /"/16 mm Typ. Drywall 2"/51 mm min. hole3.5"/89 mm 16"/406 mm Stud C/C 2.3"/ 57 mm V2707 ¾"/19 mm MAX. RECESS 2" × 4"Stud Bracket assembly Style AB5 #10 Screw V2707 MAX. EXTENSION Finished ceiling face A See chart 2⁄"/68 mmmax. hole /"/16 mmTyp. Drywall 2 ⁄"/59 mmmin. hole 3.5"/89 mm 16"/406 mm Stud C/C 2.3"/ 57 mm V3802 ½"/13 mm MAX. RECESS 2" × 4"Stud Bracket assembly Style AB5 #10 Screw V3802 MAX. EXTENSION V2707 ¾"/19mm Max. Recess V3802 ½"/13mm Max. Recess Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm A Min.3.6 91 A Min.3.3 84 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 15 victaulic.com 4.6 DIMENSIONS (C ontinued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB11 Bracket (LOW PROFILE SOLUTION) Suspended Ceiling Grid with Recessed Sprinkler with LP 90° Elbow (Long) A See chart 2 ⁄"/60 mm max. hole /"/16 mm Typical ceiling tile 2"/51 mm min. hole 3"/ 76 mm 24"/610 mm or 48"/1219 mm on Center 1.7"/43 mm Typical ceiling grid V2707 ¾"/19 mm MAX. RECESS See Note Bracket assembly Style AB11 V2707 MAX. EXTENSION Finished ceiling face Hose Clearance Chart Dimension inches mm A Min.4.0 100 Suspended Ceiling Grid with Concealed Pendent with LP 90° Elbow (Short) A See chart 2⁄"/68 mm max. hole /"/16 mm Typical ceiling tile 2 ⁄"/60 mm min. hole 3"/ 76 mm 24"/610 mm or 48"/1210 mm on Center 1.7"/43 mm Typical ceiling grid V3802 ½"/13 mm MAX. RECESS See Note Bracket assembly Style AB11 Finished Ceiling Face V3802 MAX. EXTENSION Hose Clearance Chart Dimension inches mm A Min.3.9 99 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 16 victaulic.com 4.6 DIMENSIONS (C ontinued) CLEARANCES ABOVE CEILING Series AH2 Braided Hose and Style AB3 Bracket Surface Mount Application with Recessed Sprinkler R C B 3¾"/ 95.3 mm A See Note 2/"/60 mm max. hole 2"/51 mm min. hole Hose Clearances Wall Thickness "A"2 50 4 100 6 150 8 200 10 250 2 50 4 100 6 150 8 200 10 250 Outlet Length "B" 5.75 146.1 9 228.6 13 330.2 5.75 146.1 9 228.6 13 330.2 9 228.6 13 330.2 13 330.2 13 330.2 5.75 146.1 9 228.6 13 330.2 5.75 146.1 9 228.6 13 330.2 9 228.6 13 330.2 13 330.2 13 330.2 Hose Clearance "C" 11.6 294 14.8 376 18.8 478 9.6 243 12.8 325 16.8 427 10.8 275 14.8 376 12.8 325 10.8 275 12.6 319 15.8 402 19.8 503 10.6 268 13.8 351 17.8 452 11.8 300 15.8 402 13.8 351 11.8 300 Bend Radius "R" 7 175 8 200 NOTE • Variations of ceiling grids, sprinkler heads, brackets, and hoses are permitted but may result in clearance differences from the figures above. • See installation instructions for mounting screw type and size. 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 17 victaulic.com 4.7 DIMENSIONS BRANCHLINE CLEARANCES Series AH2 Braided Hose with female threaded outlet Series AH2-CC Braided Hose with grooved outlet Female Threaded Weld Outlet R See chart A See chart 2"/50 mm RSee chart A See chart No. 142 Grooved Weld Outlet 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.8.4 214 9.4 239 10.4 264 11.4 290 12.4 315 13.41 341 A Min.7.1 180 8.1 205 9.1 231 10.1 256 11.1 281 12.1 307 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 18 victaulic.com 4.7 DIMENSIONS (Continued) BRANCHLINE CLEARANCES Series AH2 Braided Hose with Style 922 threaded outlet Series AH2-CC Braided Hose with Style 922 grooved outlet R See chart A See chart Style 922 Threaded Mechanical Tee Outlet 2"/50 mm R See chart A See chart Style 922 Grooved Mechanical Tee Outlet 2"/50 mm Hose Clearance Chart Hose Clearance Chart Dimension Dimension inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm inches mm R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 R Minimum Bend Radius 2 50 3 80 4 100 5 125 6 150 7 175 A Min.8.4 212 9.4 238 10.4 263 11.4 289 12.4 314 13.4 339 A Min.6.7 171 7.7 197 8.7 222 9.7 247 10.7 273 11.7 298 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses with Straight 5.75"/140 mm Reducers Style AB1, AB2, AB4, AB5 and AB10 Brackets Equivalent Length of 1"/33.7 mm Sch. 40 Pipe (C=120) Maximum Number of 90° Bends at 2"/51 mm Bend Radius inches/mm inches/mm/type feet/meters 31/775 ½"/15/Straight 16/4.9 4 ¾"/20/Straight 17/5.2 4 36/900 ½"/15/Straight 21/6.4 5 ¾"/20/Straight 23/7.0 5 48/1200 ½"/15/Straight 32/9.8 8 ¾"/20/Straight 37/11.3 8 60/1500 ½"/15/Straight 46/14.0 10 ¾"/20/Straight 46/14.0 10 72/1800 ½"/15/Straight 55/16.8 12 ¾"/20/Straight 53/16.2 12 Series AH2 Braided Hose with 90° Low Profile Elbows Style AB11 VicFlex Bracket Equivalent Length of 1"/33.7 mm Sch. 40 Pipe Maximum Number of 90° Bends at 2"/51 mm Bend Radius inches/mm inches/mm feet/meters 31/775 ½"/15 24/7.3 4 ¾"/20 24/7.3 4 36/900 ½"/15 26/7.9 5 ¾"/20 28/8.5 5 48/1200 ½"/15 43/13.1 8 ¾"/20 42/12.8 8 60/1500 ½"/15 49/14.9 10 ¾"/20 50/15.2 10 72/1800 ½"/15 65/19.8 12 ¾"/20 63/19.2 12 19 victaulic.com 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5.0 PERFORMANCE – FRICTION LOSS DATA (C ontinued) Series AH2 and AH2-CC Braided Hoses Equivalent Length Design Guide Equivalent length values at various numbers of 90 degree bends at 2"/51 mm center line bend radius Length of Stainless Steel Flexible Hose Outlet Size 1 Bend 2 Bends 3 Bends 4 Bends 5 Bends 6 Bends 7 Bends 8 Bends 9 Bends 10 Bends 11 Bends 12 Bends inches/ mm inches/ mm feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters feet/ meters 31/775 ½"/15 8.5/2.6 11.0/3.4 13.0/4.0 16.0/4.9 N.A N.A N.A N.A N.A N.A N.A N.A ¾"/20 10.0/3.0 12.5/3.8 14.0/4.3 17.0/5.2 N.A N.A N.A N.A N.A N.A N.A N.A 36/900 ½"/15 13.5/4.1 16.0/4.9 18.0/5.5 19.0/5.8 21.0/6.4 N.A N.A N.A N.A N.A N.A N.A ¾"/20 14.0/4.3 17.0/5.2 19.5/5.9 20.0/6.1 23.0/7.0 N.A N.A N.A N.A N.A N.A N.A 48/1200 ½"/15 15.5/4.7 17.0/5.2 19.5/5.9 20.0/6.1 21.0/6.4 22.0/6.7 28.0/8.5 32.0/9.8 N.A N.A N.A N.A ¾"/20 17.0/5.2 19.0/5.8 21.5/6.6 24.5/7.5 26.0/7.9 27.0/8.2 30.0/9.1 37.0/11.3 N.A N.A N.A N.A 60/1500 ½"/15 21.5/6.6 24.0/7.3 27.0/8.2 28.5/8.7 30.0/9.1 31.0/9.4 37.0/11.3 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A ¾"/20 23.0/7.0 24.0/7.3 28.0/8.5 29.5/9.0 30.5/9.3 31.0/9.4 38.0/11.6 42.0/12.8 44.0/13.4 46.0/14.0 N.A N.A 72/1800 ½"/15 30.0/9.1 32.0/9.8 36.5/11.1 37.5/11.4 40.5/12.5 41.0/12.8 42.0/12.8 46.0/14.0 49.0/14.9 52.0/15.8 54.0/16.5 55.0/16.8 ¾"/20 32.0/9.8 32.5/9.9 35.0/10.7 35.5/10.8 40.0/12.3 40.5/12.3 41.0/12.5 46.0/14.0 50.0/15.2 51.0/15.5 52.0/15.8 53.0/16.2 NOTES: • Values for use with 5.75"/140 mm straight reducers. How to use this Design Guide: • For some systems, it may be advantageous for the designer to calculate the system hydraulics using shorter equivalent lengths associated with fewer than the maximum allowable number of bends. In this case, the designer may select a design number of bends for the job and use the associated equivalent length from the design guide to determine the system hydraulics. • It is possible that the actual installed condition of some of the flexible drops may have more bends than the designer selected. When this happens, the design guide may be used to find equivalent lengths based on the actual installed number of bends for particular sprinkler installations. The system hydraulics can be recalculated using actual equivalent lengths to verify the performance of the system. 20 victaulic.com 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5.1 PERFORMANCE – FRICTION LOSS DATA Series AH2 and AH2-CC Braided Hoses Style AB1, AB2, AB3, AB4, AB5, AB7, AB7 Adj., AB8, AB9 and AB10 VicFlex Brackets Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of 1"/33.7mm Sch. 40 Pipe Maximum Number of 90° Bends at 7"/178mm Bend Radius inches/mm Imperial/S.I.inches/mm/type feet/meters 31/775 5.6/8.1 ½"/15/Straight 23.5/7.1 2½"/15/90˚ Elbow 23.5/7.1 36/900 5.6/8.1 ½"/15/Straight 27.8/8.5 2½"/15/90˚ Elbow 25.6/7.8 48/1200 5.6/8.1 ½"/15/Straight 38.2/11.6 3½"/15/90˚ Elbow 30.7/9.3 60/1500 5.6/8.1 ½"/15/Straight 42.4/12.9 4½"/15/90˚ Elbow 35.9/10.9 72/1800 5.6/8.1 ½"/15/Straight 46.6/14.2 4½"/15/90˚ Elbow 41.1/12.5 31/775 8.0/11.5 ¾"/20/Straight 16.8/5.1 2¾"/20/90˚ Elbow 16.8/5.1 36/900 8.0/11.5 ¾"/20/Straight 20/6.0 2¾"/20/90˚ Elbow 19.7/6.0 48/1200 8.0/11.5 ¾"/20/Straight 27.8/8.4 3¾"/20/90˚ Elbow 26.6/8.1 60/1500 8.0/11.5 ¾"/20/Straight 35.7/10.9 4¾"/20/90˚ Elbow 33.6/10.2 72/1800 8.0/11.5 ¾"/20/Straight 43.5/13.2 4¾"/20/90˚ Elbow 40.6/12.2 31/775 11.2/16.1 ¾"/20/Straight 16.5/5.0 2¾"/20/90˚ Elbow 17.8/5.4 36/900 11.2/16.1 ¾"/20/Straight 19.5/5.9 2¾"/20/90˚ Elbow 20.7/6.3 48/1200 11.2/16.1 ¾"/20/Straight 26.7/8.1 3¾"/20/90˚ Elbow 27.9/8.5 60/1500 11.2/16.1 ¾"/20/Straight 33.9/10.3 4¾"/20/90˚ Elbow 35/10.7 72/1800 11.2/16.1 ¾"/20/Straight 41.3/12.5 4¾"/20/90˚ Elbow 42.2/12.8 31/775 14.0/20.2 ¾"/20/Straight 14.9/4.5 2¾"/20/90˚ Elbow 15.5/4.72 36/900 14.0/20.2 ¾"/20/Straight 19.4/5.9 2¾"/20/90˚ Elbow 19.6/5.9 48/1200 14.0/20.2 ¾"/20/Straight 30.3/9.2 3¾"/20/90˚ Elbow 29.5/8.9 60/1500 14.0/20.2 ¾"/20/Straight 33.9/10.3 4¾"/20/90˚ Elbow 34.1/10.4 72/1800 14.0/20.2 ¾"/20/Straight 37.5/11.4 4¾"/20/90˚ Elbow 38.6/11.7 FM NOTES: • Series AH2 has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods, per FM 1637 and VdS standards. Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 21 victaulic.com 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5.2 PERFORMANCE – FRICTION LOSS DATA Series AH2 Braided Hose with 90° Low Profile Elbows Style AB11 VicFlex Bracket Length of Stainless Steel Flexible Hose K-Factor Outlet Size Equivalent Length of 1"/33.7mm Sch. 40 Pipe Maximum Number of 90° Bends at 7"/178mm Bend Radius inches/mm Imperial/S.I.inches/mm feet/meters 31/775 5.6/8.1 ½"/15 13.7/4.2 2 36/900 5.6/8.1 ½"/15 17.0/5.2 2 48/1200 5.6/8.1 ½"/15 25.0/7.6 3 60/1500 5.6/8.1 ½"/15 33.0/10.1 4 72/1800 5.6/8.1 ½"/15 41.1/12.5 4 31/775 8.0/11.5 ¾"/20 13.6/4.14 2 36/900 8.0/11.5 ¾"/20 16.9/5.2 2 48/1200 8.0/11.5 ¾"/20 27.8/8.5 3 60/1500 8.0/11.5 ¾"/20 32.6/9.9 4 72/1800 8.0/11.5 ¾"/20 40.6/12.4 4 31/775 11.2/16.1 ¾"/20 13.7/4.2 2 36/900 11.2/16.1 ¾"/20 17.0/5.2 2 48/1200 11.2/16.1 ¾"/20 24.9/7.6 3 60/1500 11.2/16.1 ¾"/20 32.9/10.0 4 72/1800 11.2/16.1 ¾"/20 40.9/12.5 4 31/775 14.0/20.2 ¾"/20 13.5/4.1 2 36/900 14.0/20.2 ¾"/20 16.8/5.1 2 48/1200 14.0/20.2 ¾"/20 24.7/7.5 3 60/1500 14.0/20.2 ¾"/20 32.7/9.9 4 72/1800 14.0/20.2 ¾"/20 40.7/12.4 4 FM NOTES: • Series AH2 has been tested and Approved by FM Global for use in wet, dry and preaction systems per NFPA 13, 13R, and 13D and FM data sheets 2-0, 2-5, and 2-8. FM 1637 and Vds standards for safety include, but are not limited to, pressure cycling, corrosion resistance, flow characterisitics, vibration resistance, leakage, mechanical and hydrostatic strength. • Differences in equivalent lengths are due to varying test methods, per FM 1637 and VdS standards. Refer to these standards for additional information regarding friction loss test methods. • EXAMPLE: A 48-inch hose installed with two 30° bends and two 90° bends at a 7-inch bend radius is permitted and considered equivalent to the data in the table shown above. In this example, the total number of degrees is 240°, which is less than the allowable 270°. 22 victaulic.com 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com 5.3 PERFORMANCE – FRICTION LOSS DATA Series AH2 Braided Hose Style AB1, AB2, AB4, AB5, AB7, AB7 Adj., AB8, AB9, AB10 and AB11 Brackets Length of Stainless Steel Flexible Hose Series AH2 Hose Outlet Size Equivalent Length of steel pipe according to EN 10255 DN 25 (33,7 x 3,25) Maximum Number of 90º Bends at 3"/76.2mm Bend Radius mm/inches mm/inches meters/feet meters/feet 775/31 15mm/½"5.5/18.0 320 mm/¾" 900/36 15mm/½"6.4/21.0 320 mm/¾" 1200/48 15mm/½"8.5/27.9 320 mm/¾" 1500/60 15mm/½"10.7/35.1 420 mm/¾" 1800/72 15mm/½"12.8/42.0 420 mm/¾" VDS CEILING MANUFACTURERS LIST AB1, AB2, AB7, AB10 ,AB11 AB4/9 AB5, AB8 1. AMF 2. Armstrong 3. Chicago Metallic 4. Dipling 5. Durlum 6. Geipel 7. Gema-Armstrong 8. Hilti 9. Knauf 10. Lafarge 11. Linder 12. Odenwald 13. Richter 14. Rigips 15. Rockfon Pagos 16. Suckow & Fischer 17. USG Donn No specific approval 1. Hilti 2. Knauf 3. Lafarge 4. Lindner 5. Rigips Series AH2 Braided Hose Style AB1 Bracket Length of Stainless Steel Flexible Hose Series AH2 Hose Outlet Size Equivalent Length of steel pipe according to EN 10255 DN 25 (33,7 x 3,25) Maximum Number of 90º Bends at 3"/76.2mm Bend Radius mm/inches mm/inches/type meters/feet 775/31 15mm/½"/Straight 1.8/6.0 220 mm/¾"/Straight 900/36 15mm/½"/Straight 3.6/11.9 320 mm/¾"/Straight 1200/48 15mm/½"/Straight 4.3/14.0 320 mm/¾"/Straight 1500/60 15mm/½"/Straight 4.1/13.6 320 mm/¾"/Straight 1800/72 15mm/½"/Straight 5.5/18.1 320 mm/¾"/Straight 23 victaulic.com 10.85 5839 Rev AA Updated 12 /2016 © 2016 Victaulic Company. All rights reserved. victaulic.com User Responsibility for Product Selection and Suitability Each user bears final responsibility for making a determination as to the suitability of Victaulic products for a particular end-use application, in accordance with industry standards and project specifications, and the applicable building codes and related regulations as well as Victaulic performance, maintenance, safety, and warning instructions. Nothing in this or any other document, nor any verbal recommendation, advice, or opinion from any Victaulic employee, shall be deemed to alter, vary, supersede, or waive any provision of Victaulic Company's standard conditions of sale, installation guide, or this disclaimer. Intellectual Property Rights No statement contained herein concerning a possible or suggested use of any material, product, service, or design is intended, or should be constructed, to grant any license under any patent or other intellectual property right of Victaulic or any of its subsidaries or affiliates covering such use or design, or as a recommendation for the use of such material, product, service, or design in the infringement of any patent or other intellectual property right. The terms “Patented” or “Patent Pending” refer to design or utility patents or patent applications for articles and/or methods of use in the United States and/or other countries. Note This product shall be manufactured by Victaulic or to Victaulic specifications. All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications, designs and standard equipment without notice and without incurring obligations. Installation Reference should always be made to I-VICFLEX-AB1-AB2-AB10, I-VICFLEX-AB4-AB9, I-VICFLEX-AB7, or I-VICFLEX-AB8 for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data, and are available in PDF format on our website at www.victaulic.com. Warranty Refer to the Warranty section of the current Price List or contact Victaulic for details. Trademarks Victaulic and all other Victaulic marks are the trademarks or registered trademarks of Victaulic Company, and/or its affiliated entities, in the U.S. and/or other countries. 6.0 NOTIFICATIONS WARNING • It is the responsibility of the system designer to verify suitability of 300-series stainless steel flexible hose for use with the intended fluid media within the piping system and external environments. • The effect of chemical composition, pH level, operating temperature, chloride level, oxygen level, and flow rate on 300-series stainless steel flexible hose must be evaluated by the material specifier to confirm system life will be acceptable for the intended service. Failure to follow these instructions could cause product failure, resulting in serious personal injury and/or property damage. 7.0 REFERENCE MATERIALS – CHARACTERISTICS Flexible Hose In-Plane Bend Characteristics One Bend Two Bends Three Bends Minimum bend radius 90° Minimum bend radius Minimum bend radius 2X Minimum bend radius OR NOTE For out-of-plane (three-dimensional) bends, care must be taken to avoid imparting torque on the hose. I-VicFlex-AB1-AB2-AB10 I-VicFlex-AB3 I-VicFlex-AB7 I-VicFlex-AB8 I-VicFlex-AB4-AB9 Minimum bend radius Minimum bend radius Minimum bend radius 2X Minimum bend radius Minimum bend radius OR 24 victaulic.com FP-4.12 PROJECT INFORMATION APPROVAL STAMP Project:q Approved Address:q Approved as noted Contractor:q Not approved Engineer:Remarks: Submittal Date: Notes 1: Notes 2: The MT-30 mechanical tee serves the same function as the MT-1 and MT-8, but uses a steel electro-plated u-bolt to save space and for easier installation in tight places.The MT-30 is ideal for direct connections with sprinkler heads and drop nipples. The MT-90 is the BSPT equivalent. For the latest UL/ULC listed, LPCB, VdS and FM Approved pressure ratings versus pipe schedule, see www.anvilintl.com or contact your local Anvil Representative. MATERIAL SPECIFICATIONS HOUSING: Ductile Iron conforming to ASTM A-536, Grade 65-45-12 U-BOLT & NUTS: U-bolt is carbon steel SAE J429 Gr. 2, zinc plated complete with hex flanged lock nuts conforming to ASTM A-563 Gr. A or B of SAE J995 Gr. 2. THREADS: NPT per ANSI/ASME B1.20.1. COATINGS: q Zinc Electroplated q Other available options: Example: RAL3000 or RAL9000 Series GASKETS: Materials Properties as designated in accordance with ASTM D-2000. q Grade “E” EPDM (Green color code) -40°F to 230°F (Service Temperature Range)(-40°C to 110°C) Recommended for water service, diluted acids, alkalies solutions, oil-free air and many chemical services not involving hydrocarbons, oils or gases. NOT FOR USE WITH HYDROCARBONS. FIG. MT-30 Threaded Mechanical Branch Tee For Listings/Approval Details and Limitations, visit our website at www.anvilintl.com or contact an Anvil® Sales Representative. FP-4.12 MT-30 THREADED MECHANICAL BRANCH TEE Nominal Size O.D. Hole Dimensions Max. Working Pressures Dimensions Approx. Wt. Ea.Min. Diameter Max. Diameter A B C TTake-out In./DN(mm)In./mm In./mm In./mm PSI/bar In./mm In./mm In./mm In./mm Lbs./Kg 11⁄4 x 1⁄2 1.660 x 0.840 13⁄16 15⁄16 300 21⁄8 31⁄2 21⁄4 15⁄8 0.8 32 x 12 42.4 x 21.3 30 33 20.7 54 89 57.2 42 0.4 11⁄4 x 3⁄4 1.660 x 1.050 13⁄16 15⁄16 300 21⁄8 31⁄2 21⁄4 15⁄8 0.8 32 x 19 42.4 x 26.7 30 33 20.7 54 89 57.2 42 0.4 11⁄4 x 1 1.660 x 1.315 13⁄16 15⁄16 300 21⁄4 31⁄2 21⁄4 15⁄8 1.1 32 x 25 42.4 x 33.7 30 33 20.7 58 89 57.2 41 0.5 11⁄2 x 1⁄2 1.900 x 0.840 13⁄16 15⁄16 300 21⁄4 31⁄2 21⁄4 13⁄4 0.8 40 x 12 48.3 x 21.3 30 33 20.7 57 89 57.2 48 0.4 11⁄2 x 3⁄4 1.900 x 1.050 13⁄16 15⁄16 300 21⁄4 31⁄2 21⁄4 13⁄4 0.9 40 x 19 48.3 x 26.7 30 33 20.7 57 89 57.2 48 0.4 11⁄2 x 1 1.900 x 1.315 13⁄16 15⁄16 300 23⁄8 31⁄2 21⁄4 13⁄4 1.1 40 x 25 48.3 x 33.7 30 33 20.7 61 89 57.2 48 0.5 2 x 1⁄2 2.375 x 0.840 13⁄16 15⁄16 300 21⁄2 33⁄4 21⁄4 2 0.9 50 x 12 60.3 x 21.3 30 33 20.7 64 95 57.2 51 0.4 2 x 3⁄4 2.375 x 1.050 13⁄16 15⁄16 300 21⁄2 33⁄4 21⁄4 2 0.9 50 x 19 60.3 x 26.7 30 33 20.7 64 95 57.2 51 0.4 2 x 1 2.375 x 1.315 13⁄16 15⁄16 300 25⁄8 33⁄4 21⁄4 2 1.1 50 x 25 60.3 x 33.7 30 33 20.7 67 95 57.2 50 0.5 21⁄2 x 1⁄2 2.875 x 0.840 13⁄16 15⁄16 300 23⁄4 41⁄4 21⁄4 21⁄4 0.9 65 x 12 73.0 x 21.3 30 33 20.7 70 108 57.2 57 0.4 21⁄2 x 3⁄4 2.875 x 1.050 13⁄16 15⁄16 300 23⁄4 41⁄4 21⁄4 21⁄4 0.9 65 x 19 73.0 x 26.7 30 33 20.7 70 108 57.2 57 0.4 21⁄2 x 1 2.875 x 1.315 13⁄16 15⁄16 300 27⁄8 41⁄4 21⁄4 21⁄4 1.1 65 x 25 73.0 x 33.7 30 33 20.7 73 108 57.2 56 0.5 For dry pipe systems and freezer applications lubrication of the gasket is required, Gruvlok® Xtreme™ Lubricant is required. BSP equivalent is available as a MT-90. s – Working Pressure Ratings are for reference only and based on Sch. 40 pipe. For the latest UL/ULC, FM, VdS and LPCB pressure ratings versus pipe schedule, please visit anvilintl.com or contact your local Anvil Representative. Note: Tighten nuts alternately to a recommended torque of 18-22 ft.-lbs. (25-30 Nm) on pipe wall less than schedule 10 (Din 2440) or 23-27 ft.-lbs. (31-37 Nm) on pipe walls schedule 10 (DIN 2440) and above. FIG. MT-30 Threaded Mechanical Branch Tee