Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ATI - Yelm, WA - Full Set
A/C ACOUS ACT AFF AFG AHU AL ALT AMT AP APPROX ARCH A/V BD BLDG BLK BM BMD BO BOT BRG BSMT CAB(S) CB C/C CG CI CJ CLG CLO CLR CM CMP CMU CO COL CONC CONSTR CONT CONTR CPT CT CTR CTSK DBL DEG DEPT DTL DIA DIAG DIM DN DR DS DWG(S) E EA EIFS EJ EL ELEC ELEV ENCL ENGR EQ EQUIP ESMT EWC EXH EXIST EXP EXT FA FCU FD FDN FE FEC FF FHC FIN FL FLR FT FTG FUT FWC GA GALV GB GC GEN GFB GFRC GFRG GL GND GWB H HB HC HDCP HD HDW HM HORIZ HP HGT HTR HWH HVAC AIR CONDITIONING ACOUSTICAL ACOUSTICAL CEILING TILE ABOVE FINISH FLOOR ABOVE FINISH GRADE AIR HANDLING UNIT ALUMINUM ALTERNATE AMOUNT ACCESS PANEL APPROXIMATE ARCHITECTURAL AUDIO VISUAL BOARD BUILDING BLOCK BEAM OR BENCHMARK BOTTOM OF METAL DECK BOTTOM OF BOTTOM BEARING BASEMENT CABINET(S) CORNER BEAD CENTER TO CENTER CORNER GUARD CAST IRON CONTROL JOINT CEILING CLOSET CLEAR CENTIMETER COMPOSITE METAL PANEL CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONCRETE CONSTRUCTION CONTINUOUS CONTRACTOR CARPET CERAMIC TILE CENTER COUNTERSINK DOUBLE DEGREE DEPARTMENT DETAIL DIAMETER DIAGONAL DIMENSION DOWN DOOR DOWNSPOUT DRAWING(S) EAST EACH EXTERIOR INSULATION FINISH SYSTEM EXPANSION JOINT ELEVATION ELECTRICAL ELEVATOR ENCLOSURE ENGINEER EQUAL EQUIPMENT EASEMENT ELECTRIC WATER COOLER EXHAUST EXISTING EXPANSION EXTERIOR FIRE ALARM FAN COIL UNIT FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FIRE HOSE CABINET FINISH FLOW LINE FLOOR FEET FOOTING FUTURE FABRIC WALL COVERING GAUGE GALVANIZED GRAB BAR GENERAL CONTRACTOR GENERATOR GROUND FACE BLOCK GLASS FIBER REINFORCED CONCRETE GLASS FIBER REINFORCED GYPSUM GLASS GROUND GYPSUM WALL BOARD HIGH HOSE BIB HOLLOW CORE HANDICAP HEAD HARDWARE HOLLOW METAL HORIZONTAL HIGH POINT HEIGHT HEATER HOT WATER HEATER HEATING VENTILATING AND AIR CONDITIONING ID IN INCL INFO INSUL INT JAN JB JST JT L LAB LAM LAV LB LF LH LKR LP M MA MAS MATL MAX MB MECH MFR MH MIN MISC MM MO MTD MTL N NIC NO NOM NTS OA OC OD OH OHD OPNG OPP OPP HD ORD OPT ORIG OZ PARTN PC PERF PJ PL PLAS P LAM PLG PLYWD PNL PR PREFAB PRELIM PROJ PSF PSI PT PTD QT QTR R R/A RAD RB RD REF REINF RF REFRG REQD RET REV RH RM RO RTU RV INSIDE DIAMETER INCH INCLUDE (ED) (ING) INFORMATION INSULATION INTERIOR JANITOR JUNCTION BOX JOIST JOINT LENGTH LABORATORY LAMINATE LAVATORY POUND LINEAR FEET LEFT HAND LOCKER LOW POINT METER MARBLE MASONRY MATERIAL MAXIMUM MARKER BOARD OR MOP BASIN MECHANICAL MANUFACTURER MANHOLE MINIMUM MISCELLANEOUS MILLIMETER MASONRY OPENING MOUNTED METAL NORTH NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OVER ALL ON CENTER OUTSIDE DIAMETER OVERHEAD OVERHEAD DOOR OPENING OPPOSITE OPPOSITE HAND OVERFLOW ROOF DRAIN OPTIONAL ORIGINAL OUNCE PARTITION PRECAST PERFORATED PANEL JOINT PLATE PLASTER PLASTIC LAMINATE PLUMBING PLYWOOD PANEL PAIR PREFABRICATED PRELIMINARY PROJECT POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POINT PAINTED OR PAPER TOWEL DISPENSER QUARRY TILE QUARTER RISER RETURN AIR RADIUS RESILIENT BASE ROOF DRAIN REFERENCE REINFORCED (ING) RESILIENT FLOORING REFRIGERATOR REQUIRED RETAINING REVISION RIGHT HAND ROOM ROUGH OPENING ROOF TOP UNIT ROOF VENT S S/A SAB SAN SD SF SHR SHT SIM SM SNR SPEC(S) SPKR SQ SS ST STD STL STOR STRL STRUCT SUSP SYM SYS T T&G TELE TEM TEMP TERR THK THRU TO TPH TSS TSTL TU TV TW TYP UH UNFIN UL UON VB VENT VERT VEST VIF VWC W W/ W/O WC WD WG WP WPT WSCT WT WWF XMFR SOUTH SUPPLY AIR SOUND ATTENUATION BLANKET SANITARY SMOKE DETECTOR SQUARE FEET SHOWER SHEET SIMILAR SQUARE METER SANITARY NAPKIN RECEPTACLE SPECIFICATION(S) SPEAKER SQUARE STAINLESS STEEL STREET STANDARD STEEL STORAGE STRUCTURAL STRUCTURE SUSPENDED SYMMETRICAL SYSTEM TREAD TONGUE & GROOVE TELEPHONE TEMPERED TEMPORARY TERRAZZO THICK THROUGH TOP OF TOILET PAPER HOLDER TOP STRUCTURAL SLAB TOP OF STEEL TILT-UP TELEVISION TOP OF WALL TYPICAL UNIT HEATER UNFINISHED UNDERWRITER'S LABORATORY UNLESS OTHERWISE NOTED VAPOR BARRIER VENTILATION VERTICAL VESTIBULE VERIFY IN FIELD VINYL WALL COVERING WEST WITH WITH OUT WATER CLOSET WOOD WALL GUARD WATERPROOFING WORKING POINT WAINSCOT WEIGHT WELDED WIRE FABRIC TRANSFORMER T A H O M A B L V D S O U T H E A S T AREA OF WORK Y E L M H W Y _____ A100 1 12 A601 DETAIL KEY DETAIL # SHEET # ELEVATION KEY DETAIL # SHEET # SECTION KEY DETAIL # SHEET # NORTH ARROW TRUE NORTH REVISION CLOUD COLUMN GRID 0 0 TAG KEY KEYNOTE DOOR TAG ROOM TAG CEILING HEIGHT TAG ROOM NAME 100 10'-0" ### # WALL TAG WALL TYPE HEIGHT OF WALL 1A T SYMBOL KEY GENERAL NOTES APPLICABLE CODE DRAWING INDEXPROJECT LOCATIONABBREVIATIONS PROPOSED COMMERCIAL TENANT REMODEL SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T R E M O D E L Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No 201 TAHOMA BLVD SE, SUITE 207, YELM, WA 98597 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M , W A 9 8 5 9 7 LOD COVER SHEET, SITE PLAN & CODE DATA G100 1 Sheet # Sheet Name ARCHITECTURAL G100 COVER SHEET, SITE PLAN & CODE DATA G101 ACCESSIBILITY DIAGRAM & TYPICAL MOUNTING HEIGHTS A100 FLOOR PLAN & DEMO PLAN A101 WALL FINISH PLAN AND REFLECTED CEILING PLAN A200 INTERIOR ELEVATIONS A500 DETAILS A600 WALL DETAILS, NOTES, & SCHEDULES A601 WALL DETAILS, DOOR DETAILS, & SCHEDULES ECA ECA100 ENERGY COMPLIANCE ANALYSIS ELECTRICAL DE100 FLOOR PLAN - ELECTRICAL DEMOLITION E100 FLOOR PLAN - POWER & SYSTEMS E200 FLOOR PLAN - LIGHTING E300 ELECTRICAL DETAILS & SCHEDULES E301 ELECTRICAL SCHEDULES, GEN. NOTES, & SYMBOLS FIRE PROTECTION FP100 FLOOR PLAN - FIRE PROTECTION MECHANICAL DM100 FLOOR PLAN - MECHANICAL DEMOLITION M100 FLOOR PLAN - MECHANICAL M200 MECHANICAL SCHEDULES, GEN. NOTES, & SYMBOLS MEP MEP100 SPECIFICATIONS MEP101 SPECIFICATIONS PLUMBING DP100 FLOOR PLAN - PLUMBING DEMOLITION P100 FLOOR PLAN - PLUMBING P200 PLUMBING SCHEDULES, GEN. NOTES, & SYMBOLS 1. WORK SHALL CONFORM TO ALL STATE AND LOCAL APPLICABLE BUILDING CODES, REGULATIONS AND ORDINANCES HAVING JURISDICTION. 2.SEE SHEET A601 FOR PARTITION TYPES AND TYPICAL PARTITION NOTES. 3.CONTRACTOR SHALL VERIFY ALL CONDITIONS , DIMENSIONS, AND SHALL COORDINATE WITH TRADES IN LAYOUT OF HIS WORK. THE ALIGNMENT IN COORDINATION OF HIS WORK AND OTHER ADJACENT WORK IS OF PRIMARY IMPORTANCE AND SHALL TAKE PRECEDENCE OVER DIMENSIONS. CONTRACTOR SHALL LAYOUT AND VERIFY HIS WORK TO ENSURE PROPER ALIGNMENT AND FIT. CONTRACTOR SHALL IMMEDIATELY REPORT ANY DISCREPANCIES TO HIS SUPERINTENDENT AND THE ARCHITECT BEFORE PROCEEDING, OR PROCEED AT CONTRACTOR'S OWN RISK. 4.CONTRACTOR SHALL WORK FROM ESTABLISHED POINTS AND LINES, ESTABLISH AND MAINTAIN MARKERS FOR LINES AND LEVELS OF WORK. DO NOT SCALE DRAWINGS, CALCULATE DIMENSIONS AND MEASURE FOR LAYOUT OF WORK. CONTRACTOR SHALL REPORT IMMEDIATELY ANY DISCREPANCIES TO HIS SUPERINTENDENT AND THE ARCHITECT BEFORE PROCEEDING, OR PROCEED AT CONTRACTOR'S OWN RISK. 5.THE WORD 'ALIGN' AS IN THESE DOCUMENTS SHALL SUPERSEDE ANY DIMENSIONAL INFORMATION SHOWN. IF A DISCREPANCY OCCURS, NOTIFY THE SUPERINTENDENT AND ARCHITECT IMMEDIATELY. 6.CONTRACTOR SHALL INSPECT, REMOVE AND REPLACE ALL FAULTY GLAZING AND FRAMING MATERIALS. 7.PROVIDE SUBMITTALS FOR ARCHITECTS TO REVIEW FOR: • HVAC EQUIPMENT AND TRIM • PLUMBING FIXTURES • ELECTRICAL FIXTURES • FLOORING • CASEWORK / MILLWORK • PAINT / WALL PROTECTION • DOORS AND HARDWARE • CUSTOM STOREFRONT 8.PROPOSED SPRINKLER SYSTEM TO BE PERFORMED AS DESIGN-BUILD AND SUBMITTED UNDER SEPARATE COVER BY SELECTED FIRE PREVENTION SPECIALIST/ SUB-CONTRACTOR. 9.CONFIRM ALL HEIGHTS AND LOCATION OF ELECTRICAL FIXTURES, OUTLETS AND PLUMBING FIXTURES WITH ARCHITECTURAL ELEVATIONS. REPORT ANY CONFLICTS/ DISCREPANCIES TO ARCHITECT PRIOR TO CONSTRUCTION. (AS MODIFIED BY LOCAL AMENDMENTS) 12" = 1'-0"1 LOCATION PLAN THIS PROJECT HAS BEEN DESIGNED TO COMPLY WITH THE FOLLOWING STANDARD CODES AS ESTABLISHED BY THE CITY OF YELM, WA: 2021 International Building Code 2020 National Electrical Code 2021 Washington State Plumbing Code 2021 International Mechanical Code 2021 International Fire Code PERMIT SET 08/06/25 JLC 08/05/2025 SIZE OF CLEAR FLOOR SPACE 52" MIN 30 " M I N SIZE OF TURNING SPACE (a) CIRCULAR 30 " M I N 52" MIN 30" MIN 52 " M I N (b) PARALLEL(a) FORWARD POSITION OF CLEAR FLOOR SPACE 60" MIN36" MIN X > 1 5 " X > 2 4 " (a) FORWARD APPROACH (b) PARALLEL APPROACH MANEUVERING CLEARANCE IN AN ALCOVE (b) T-SHAPED 64" MIN 40 " M I N 2 0 " M I N 60 " M I N 12" MIN 40" MIN 12" MIN 67" UNOBSTRUCTED FORWARD REACHOBSTRUCTED HIGH FORWARD REACHUNOBSTRUCTED SIDE REACHOBSTRUCTED HIGH SIDE REACH 48 " M A X 15 " M I N 44 " M A X 20"-25"20" MAX 48 " M A X 10" MAX 15 " M A X (a)(b)(a)(b) 48 " M A X 34 " M A X 46 " M A X >10"-24"10" MAX 34 " M A X 48 " M A X MIRROR 40 " M A X 34 " M A X (a) FRONT APPROACH, PULL SIDE (b) FRONT APPROACH, PUSH SIDE *IF BOTH CLOSER AND LATCH ARE PROVIDED 52 " M I N 12" MIN* 60 " M I N 36" MIN (c) HINGE APPROACH, PULL SIDE (d) HINGE APPROACH, PULL SIDE 52 " M I N 42" MIN 42 " M I N * * 12" MIN* 22" MIN (e) HINGE APPROACH, PUSH SIDE *IF BOTH CLOSER AND LATCH ARE PROVIDED (g) LATCH APPROACH, PUSH SIDE **48" MIN IF BOTH CLOSER & LATCH ARE PROVIDE 48 " M I N * 24" MIN *54" MIN IF CLOSER IS PROVIDED (f) LATCH APPROACH, PULL SIDE *48" MIN IF CLOSER IS PROVIDED 42 " M I N * 24" MIN 30 " M I N 17"-25" 9" 6" MAX TOE CLEARANCE (a) ELEVATION (b) PLAN 30 " M I N 25" MAX 9" M I N 11" MIN 27 " M I N 8" MIN KNEE CLEARANCE (a) ELEVATION (b) PLAN (a) PLAN (b) ELEVATION 38 " - 4 3 " 36 " M A X 9" M I N ST A N D I N G PE R S O N S W H E E L C H A I R AC C E S S I B L E 5" MAX 15" MIN (a) ACCESSIBLE WATER CLOSET (a) AMBULATORY ACCESSIBLE WATER CLOSET WATER CLOSET LOCATION CL CL 16"-18"17"-19" 60" MIN 56 " M I N SIZE OF CLEARANCE FOR WATER CLOSET NO THER FIXURES PERMITTED WITHIN THIS AREA (a) PROTRUDING DISPENSER BELOW GRAB BAR (b) PROTRUDING DISPENSER ABOVE GRAB BAR (b) RECESSED DISPENSER 18 " M I N 48 " M A X 24" MIN 36" MAX 42" MAX 24" MIN 36" MAX 48 " M A X 12 " M I N 18 " M I N 1 1 / 2 " M I N 24" MIN 42" MAX AC C E S S I B L E 48 " TO T . O . F I R E 60 " M A X H E I G H T 42 " EX T I N G U I S H E R CL WALL-MOUNTED DEFIBRILLATOR CABINET FIRE EXTINGUISHER CABINET FIRE ALARM PULL STATION & AUDIBLE/VISUAL ALARM 80 " 48 " PULL STATION AUDIBLE/VISUAL ALARM AC C E S S I B L E 43 " NO N - A C C E S S I B L E 60 " EQ EQ CL TY P 18 " AB O V E 44 " CL CL DOOR PEEPHOLEELECTRICAL / TELE / DATA OUTLET CO U N T E R LINE OF COUNTERTOP ROOM SIGNAGE ROOM NAME WALL MOUNTED CARD READER LIGHT SWITCH W/ THERMOSTAT THERMOSTATLIGHT SWITCH CL8" SE E D E T A I L # 1 3 DO O R DO O R THERMOSTAT LIGHT SWITCH 48 " 48 " 48 " DO O R CL8" 42 " 8" 12" CLCL HE I G H T O F 42 " CO N T R O L S LINE OF COUNTERTOP ABOVE COUNTER HOT/COLD WATER DISPENSER (PURLOGIX PCMV-1000E) WALL-MOUNTED DIAPER CHANGING STATION FOR INFANTS & SMALL CHILDERN 48 " M A X * FRONT ELEVATIONSIDE ELEVATION * TO TOP OF OPERABLE PORTION ** TO HIGHEST POINT OF WORK SURFACE *** TO BOTTOM OF WORKSURFACE 17"-25" MA X * * * 27 " 34 " M A X * * 48 " M A X * NO N - A C C E S S I B L E 60 " AC C E S S I B L E 42 " CLOTHING HOOKTOWEL BARSHELF AC C E S S I B L E 48 " T.O. BAR T.O. CONTROL AC C E S S I B L E 48 " T.O. SHELF AC C E S S I B L E 48 " AC C E S S I B L E 37 " B.O. DRYER SANITARY NAPKIN VENDOR HAND DRYERPAPER DISPENSER W/ WASTE RECEPTACLE (LARGE) PAPER DISPENSER W/ WASTE RECEPTACLE (TYP) SOAP DISPENSER T.O. DISPENSING LOCATION AC C E S S I B L E 48 " AC C E S S I B L E 48 " T.O. DISPENSING LOCATION T.O. CONTROL AC C E S S I B L E 48 " WATER CLOSET SEAT HEIGHTHEIGHT OF URINALS (a) WALL-HUNG TYPE (b) STALL TYPE SE A T 17 " - 1 9 " HE I G H T MA X 17 " MI N 18 " 3 9 " - 4 1 " 33 " - 3 6 " MAX 12"42" MIN 39"-41" 54" MIN CL 33 " - 3 6 " MIN 24" MIN 12" 36" MIN CL SIDE WALL GRAB BAR FOR WATER CLOSET REAR WALL GRAB BAR FOR WATER CLOSET SPACING OF GRAB BARS SIZE OF GRAB BARS (a) CIRCULAR (b) NONCIRCULAR (c) NONCIRCULAR 1 1/4"-2"MAX 2" MI N 1 1 / 2 " 12 " M I N 1 1/2" 4"-4.8" PERIMETERAREA OF REFUGE AREA OF REFUGE 60 " M A X 48 " M I N 60 " M A X 48 " M I N RAISED CHARACTERS BRAILLE HEIGHT OF RAISED CHARACTERS & BRAILLE ABOVE FLOOR CENTERED ON RASIED CHARACTERS MI N 18 " MIN 18" CL 45° LIBRARY 5/ 8 " - 2 " B CB D A BLANK CELL SPACE BETWEEN WORDS RAISED DOT NO RAISED DOT SINGLE BRAILLE CELL KEY MEASUREMENT RANGE MIN MAX A B C D DOT BASE DIAMETER DISTANCE BETWEEN TWO DOTS IN THE SAME CELL DISTANCE BETWEEN CORRESPONDING DOTS IN THE ADJACENT CELLS* DISTANCE BETWEEN CORRESPONDING DOTS FROM ONE CELL DIRECTLY BELOW* DOT HEIGHT *MEASURED CENTER TO CENTER BRAILLE DIMENSIONS 0.025"0.037" 0.395"0.400" 0.241"0.300" 0.090"0.100" 0.059"0.063" BRAILLE DIAGRAM MEN NOT INCLUDED PICTOGRAM FIELD 6" M I N ACCESSIBILITY NOTES THE PROJECT MEETS FULL COMPLIANCE WITH ICC/ A117.1, 2009 & ADA. CONTROLS & OPERATING MECHANISMS: ALL OPERABLE PARTS SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE OPERABLE PARTS SHALL BE 5 POUNDS MAXIMUM. ALL ALTERED CONTROLS & OPERATING MECHANISMS SHALL BE PLACED BETWEEN 15 INCHES & 48 INCHES ABOVE THE FLOOR. FLOORING: ALL FLOORING SURFACES SHALL BE FIRM, STABLE, & SLIP-RESISTANT PER ICC/ANSI A117.1 CHAPTER 3, SECTION 302.1. THRESHOLDS SHALL NOT EXCEED 1/2”WITH A 1:2 BEVEL. PLUMBING FACILITIES: ALL PLUMBING FACILITIES SHALL COMPLY WITH ICC/ANSI A117.1 CHAPTER 6. ALARMS: ALL NEW OR ALTERED VISUAL ALARMS SHALL COMPLY WITH ICC/ANSI A117.1 CHAPTER 7. ALL VISUAL ALARMS SHALL BE SYNCHRONIZED. DOORS: • DOORS IN PUBLIC & COMMON AREAS SHALL PROVIDE THE REQUIRED MANEUVERING CLEARANCE PER ICC/ANSI A117.1 CHAPTER 4. • ALL DOORS SHALL HAVE LEVER-OPERATED HARDWARE PER ICC/ANSI A117.1 CHAPTER 4. • ALL DOORS SHALL HAVE A 32”CLEAR DOOR OPENING MEASURED FROM THE FACE OF THE DOOR WHEN IT IS OPENED 90° TO THE DOOR STOP PER ICC/ANSI A117.1 CHAPTER 4. • ALL DOORS LEADING INTO HAZARDOUS ROOMS OR SPACES TO HAVE KNURLED HARDWARE. • ALL PUBLIC & COMMON AREA INTERIOR DOORS TO HAVE 5-POUND MAXIMUM FORCE TO OPEN PER ICC/ANSI A117.1 CHAPTER 4, SECTION 404.2.8. PROTRUDING OBJECTS: ALL PROTRUDING OBJECTS ON CIRCULATION PATHS SHALL MEET COMPLIANCE WITH ICC/ANSI A117.1 CHAPTER 3. OBJECTS WITH LEADING EDGES MORE THAN 27”AND NOT MORE THAN 80”A.F.F. SHALL PROTRUDE 4”MAX. HORIZONTALLY INTO THE CIRCULATION PATH. GUARDRAILS OR OTHER BARRIERS SHALL BE PROVIDED WHERE OBJECT PROTRUSION IS BEYOND THE LIMITS ALLOWED. THE LEADING EDGE OF GUARDRAIL OR BARRIER SHALL BE 27”MAXIMUM A.F.F. SIGNAGE: WHERE SIGNAGE IS PROVIDED, IT SHALL COMPLY WITH ICC/ANSI A117.1 CHAPTER 7. IF USED TO IDENTIFY REQUIRED ACCESSIBLE ELEMENTS, PROVIDE DIRECTIONS OR INDICATE SPECIAL ACCESSIBILITY PROVISIONS. SIGNAGE DIMENSIONS, CHARACTERS, & TACTILE FEATURES SHALL COMPLY WITH ICC/ANSI A117.1 CHAPTER 7. SIGNAGE SHALL BE PROVIDED TACTILE IN BRAILLE & LOCATED ON THE DOOR HANDLE SIDE OF THE DOOR. NEW SIGNAGE WILL BE INSTALLED AT THE APPROPRIATE HEIGHT & DISTANCE TO THE LATCH SIDE OF THE DOOR PER THE ELEVATION DETAIL ON THE DRAWINGS. SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T R E M O D E L Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M , W A 9 8 5 9 7 NRS ACCESSIBILITY DIAGRAM & TYPICAL MOUNTING HEIGHTS G101 1 1/4" = 1'-0"1 CLEAR FLOOR SPACE 1/4" = 1'-0"2 REACH RANGES 1/4" = 1'-0"3 HEIGHT OF LAVATORIES SINKS & MIRRORS 1/4" = 1'-0"4 MANEUVERING CLEARANCE AT MANUAL SWING DOORS 1/4" = 1'-0"5 KNEE & TOE CLEARANCE 1/4" = 1'-0"6 DRINKING FOUNTAIN SPOUT LOCATION 1/4" = 1'-0"7 WATER CLOSET LOCATION & CLEARANCE 1/4" = 1'-0"8 TOILET PAPER DISPENSER OUTLET LOCATIONS 1/4" = 1'-0"9 TYPICAL MOUNTING HEIGHTS 1/4" = 1'-0"10 WATER CLOSET SEAT & URINAL HEIGHT 1/4" = 1'-0"11 WATER CLOSET GRAB BAR LOCATIONS 1/2" = 1'-0"12 SIZE & SPACING OF GRAB BAR NTS13 HEIGHT OF RAISED CHARACTERS & BRAILLE ABOVE FLOOR 1/4" = 1'-0"14 LOCATION OF SIGNS AT DOORS NTS15 CHARACTER HEIGHT NTS16BRAILLE DIAGRAM & DIMENSIONS NTS17 PICTOGRAM FIELD PERMIT SET 08/06/25 JLC 08/05/2025 RECEPTION 121 (E) WAITING 120 (E) MECH 130 HOSPITALITY 123 (E) OPEN TREATMENT 128 OPEN GYM 127 (E) TREATMENT 125 TOILET 124 (E) TOILET 122 9 7 11 15 2628 RELOCATED LEG PRESS (E) TREATMENT 126 RELOCATED ADJUSTABLE BENCH AND RACK SWISS BALL RACK (E) LAUNDRY/BREAK ROOM 129 WEIGHT RACK MED BALL RACK (3) TUBE STEEL SUPPORTS IN HALF-WALLS SPACED AT 4' OC BALANCE BARRE WITH MIRROR WALL MOUNTED WEB SLIDE (WILL HAVE REINFORCED ATTACHMENT AT WALL) A200 3 4 A200 1 2 14 11 15 3' - 0" 3' - 0 " HALF WALL TO ALIGN WITH CORNER OF EXISTING WALL 5' - 5 " 5' - 10 1/2" CURTAIN MOUNTED TO CEILING ABOVE 3' - 1 1 " 127 2A S RELOCATED TREATMENT TABLE 11 TYP OF 2 11 15 15 TYP OF 4 2A 3'-6" 2A 3'-6" TYP OF 2 11 TYP OF 5 6 30"x48" CLEAR AND LEVEL FLOOR SPACE 56"x60" CLEAR AND LEVEL FLOOR SPACE ALIGN EDGE OF NEW WALL TO EXISTING 2' - 2" WALL KEY - EXISTING WALL - WALL TO BE DEMOLISHED - NEW WALL - NEW WALL WITH SOUND BATT - NEW WALL WITH THERMAL BATT - NEW HALF WALL DEMO DOOR AND FRAME DEMO DOOR AND FRAME DEMO WALLS RELOCATE LEG PRESS RELOCATE WEIGHT RACK AND MED BALL RACK DEMO CARPET FLOORING DEMO CARPET FLOORING DEMO CARPET FLOORING DEMO CARPET FLOORING DEMO CARPET FLOORING DEMO CARPET FLOORING DEMO CARPET FLOORING RELOCATE BENCH AND RACK DEMO HOSPITALITY RELOCATE SWISS BALL RACK DEMO CASEWORK DEMO BULKHEAD RELOCATE PHYSIO TABLE DEMO DOOR AND FRAME DEMO WALL DEMO PLUMBING FIXTURES AND ACCESSORIES. CAP PLUMBING BELOW THE FLOOR DEMO WALL DEMO WALL SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T R E M O D E L Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M , W A 9 8 5 9 7 LOD FLOOR PLAN & DEMO PLAN A100 1 3/16" = 1'-0"1 FLOOR PLAN FLOOR PLAN - KEY NOTES Key Value Keynote Text 6 HALF-WALL PLAM CAP & END STANCHION , SEE 3/A500 AND 4/A500 7 CONCIERGE DESK NOTE: PROVIDE CONCIERGE DESK, SEE SHEET A501; CONTACT TRINITY MILLWORKS INC FOR ORDERING. NO SUBSTITUTIONS. EMAIL: TFERGUSON@TRINITY-COMPANIES.COM, PHONE: 717.654.8802 MOUNT REQ. I.T. POWER STRIP TO UNDERSIDE OF PLAM COUNTER 9 PRINTER/ FAX MACHINE BY GC 11 FURNITURE BY GC 14 PROVIDE NEW HOSPITALITY TABLE , SEE SHEET A501 FOR DETAILS 15 TRANSITION STRIP: PROVIDE PRE-MANUFACTURED STRIP EDGE W/ THRESHOLD TRANSITION TO SNAP IN @ VINYL FLOORING / CHANGE NOT TO EXCEED 1/2" IN HEIGHT W/ BEVELS NOT TO EXCEED 1:2 RATIO (ON ALL EDGES OF RUBBER FLOORING, JOHNSONITE BLACK # 40) 26 WALL MOUNTED BALANCE BARRE, SEE DETAIL 9/A500 28 WALL MOUNTED MIRRORS, GLUED AND SCREWED TO WALL, VERIFY LOCATION WITH OWNER GENERAL NOTES ROOFING NOTE: GC TO CONFIRM ALL EXISTING AND RESULTING DEMOLITION ROOF PENETRATIONS, REPAIR AND SEAL AS REQ. THIS SHOULD BE INCLUDED IN BID. VERIFY IF LL ROOFER NEEDS TO BE ENGAGED FOR THIS WORK AND PRICE ACCORDINGLY 3/16" = 1'-0"2 DEMO PLAN PERMIT SET 08/06/25 JLC 08/05/2025 2" 2 1/2" 1/ 8 " 1/ 8 " JOHNSONITE CTA-XX-N: 1/8" RESILIENT > 1/8" RESILIENT 2" 2 1/2" 1/ 2 " 1/ 8 " JOHNSONITE CTA-XX-H: CARPET > VINYL 2" 2 1/2"3/ 8 " 1/ 4 " JOHNSONITE CTA-XX-L: RUBBER FLOORING > CARPET RUBBER FLOORING > VINYL USE FLEXIBLE TRANSITION STRIP @ RADIUS FLOOR ALL TRANSITION STRIPS TO BE JOHNSONITE BLACK #40 TRANSITION STRIP GENERAL NOTES (E) OPEN TREATMENT OPEN GYM (E) TREATMENT (E) TREATMENT TOILET (E) TOILET HOSPITALITY (E) WAITING RECEPTION (E) LAUNDRY/BREAK ROOM (E) MECH NEW GYP CEILING EXISTING ACT CEILING EXISTING ACT CEILING EXISTING GYP CEILING EXISTING ACT CEILING EXISTING GYP CEILING C NEW ACT CEILING NEW ACT CEILING HANG SHEET HORIZONTALLY 30" A.F.F. W/TOP @ 6'-6" 30'-0" LINEAL NOTE: VERIFY EXTENT OF WALL PROTECTION WITH OWNER DIRECTION OF RUBBER FLOORING RUBBER VINYL PLANK RUBBERVINYL PLANK COLUMN TO BE PAINTED PT-1 ON ALL SIDES, TYP ON ALL COLUMNS WITHIN THE SPACE VINYL WOOD FLOORING DI R E C T I O N O F V I N Y L F L O O R I N G EXISTING CERAMIC TILE FLOORING PT-3 PT -3 PT -3 PT-2 PT-3 PT -3 PT -3 PT-2 PT-3 PT-3 PT -3 PT -3 (E) WAITING 120 RECEPTION 121 (E) MECH 130 (E) LAUNDRY/BREAK ROOM 129 HOSPITALITY 123 OPEN GYM 127 (E) OPEN TREATMENT 128 PT-1 PT-2 PT -3 PT-3 VINYL FLOORING 114 SF (E) TREATMENT 126 114 SF (E) TREATMENT 125 67 SF TOILET 124 47 SF (E) TOILET 122 PT-3 PT-3 PT -3 PT -3 PT -2 PT -2 VINYL WOOD FLOORING EXISTING FLOORING PT-3 PT-3 PT-3 PT-3 PT -3 PT -3 PT -3 PT -3 PT-2 PT -1 PT -2 PT -2 PT-2 PT-2 PT-3 PT -3 PT-3 PT-3PT-3 PT-3 PT -3 PT-3 PT -3 PT-3 PT -3 PT -3PT-3TOP OF MIRRORS TO BE MOUNTED 8'-0" AFF CUT HOLE IN MIRROR FOR BARRE MOUNT, SEE DETAILS MIRRORS TO BE MADE OF SAFETY GLAZING AS DEFINED BY 2018 IBC MIRROR RUBBER VINYL PLANK DIRECTION OF VINYL FLOORING DI R E C T I O N O F VI N Y L F L O O R I N G DI R E C T I O N O F VI N Y L F L O O R I N G DIRECTION OF VINYL FLOORING IN TOILET ROOMS IS RIGHT TO LEFT WP-1 SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T R E M O D E L Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M , W A 9 8 5 9 7 LOD WALL FINISH PLAN AND REFLECTED CEILING PLAN A101 1 RCP - KEY NOTES Key Value Keynote Text C CEILING MOUNTED CURTAIN TRACK AND CURTAIN (FB-1) FINISH GENERAL NOTES FLOOR FINISHES NOTE: CERAMIC TILE TO BE SLIP RESISTANT. CARPET TO HAVE BACKING & MUST BE GLUED SECURELY TO SUBFLOOR W/ NO PAD. CARPET PILE SHALL BE LEVEL W/ 1/2" MAX. HT. ALL EXPOSED CARPET EDGES TO BE SECURED W/ TRANSITION STRIP. ALL RUBBER FLOORING TO BE SECURED DIRECTLY TO SUBFLOOR. CUBICLE CURTAIN NOTE: CURTAIN TO HAVE 20" MESH TOP AND BE 15" A.F.F. PER MANUFACTURERS SPECIFICATIONS. PAINTING CONTRACTOR TO PRIME ALL SURFACES, DO NOT PAINT BEHIND MIRRORS OR FRP. PRIMER AND FIRST COAT TO BE APPLIED BEFORE FLOORING INSTALLATION, FINAL COAT AFTER FLOORING INSTALLED. REMOVE EXIST. WALLCOVERING FROM PERIMETER WALLS, PREPARE AS REQUIRED FOR PAINT FINISH. PROVIDE ALLOWANCE FOR 24 LINEAL FEET OF MIRRORS (6' TALL, TOP @ 8' A.F.F.), VERIFY LOCATION WITH OWNER ALL HOLLOW METAL FRAMES TO BE PT-2 TYP. REMOVE FLOORING AS REQUIRED AND REPAIR / PREPARE FLOOR SLAB FOR PROPER INSTALLATION OF NEW FLOOR MATERIALS ALL TRANSITION STRIPS TO BE JOHNSONITE BLACK #40 HOSPITALITY VINYL FLOORING NOTE: ALL VINYL FLOORING TO BE INSTALLED IN THE DIRECTION RUNNING PARALLEL TO MILLWORK IN HOSPITALITY AREA. VINYL BASE NOTE: FIELD APPLY LAMINATE BASE; SCRIBE AS REQUIRED DUE TO UNEVEN FLOORS. VCT FLOORING FLOOR DRAINS: PROVIDE SQUARE FLOOR DRAIN COVERS AT ANY FLOOR DRAIN IN VCT FLOORING AREA WALL PROTECTION: WALL PROTECTION TO HAVE TRIP PIECE AT TOP, BOTTOM, SIDES, AND MIDDLE JOINTS. PROVIDE CORNER GUARDS AT ANY OPEN EDGE CORNER SCHEDULED TO RECEIVE PROTECTION PAINT APPLICATION: APPLY PAINT BY SPRAY APPLICATION MATERIALS SCHEDULE MARK DESCRIPTION FLAME SPREAD RATING/ FIRE RESISTANCE VCT-1 VINYL COMPOSITE TILE; ARMSTRONG - STANDARD EXCELON #51915 CHARCOAL; INSTALLED AT A 1/4 TURN ASTM E 648 (0.45 W / CM² OR MORE CLASS I) VB-1 4" VINYL COVE BASE; 4" PATCRAFT CADBURY FOR NATIONAL PRICING CONTACT: HOWARD CARROLL; (630) 809-6867 MOBILE, (630) 527-0493 FAX, howard.carroll@patcraft.com UL 992 - FLAME PROPAGATION - < 2.0; ASTM E- 84 CLASS II VB-2 6" VINYL COVE BASE; 6" PATCRAFT CADBURY FOR NATIONAL PRICING CONTACT: HOWARD CARROLL; (630) 809-6867 MOBILE, (630) 527-0493 FAX, howard.carroll@patcraft.com UL 992 - FLAME PROPAGATION - < 2.0; ASTM E- 84 CLASS II VF-1 VINYL FLOORING; PATCRAFT - BUBBLES II LVP FOR NATIONAL PRICING CONTACT: HOWARD CARROLL; (630) 809-6867 MOBILE, (630) 527-0493 FAX, howard.carroll@patcraft.com ASTM F 1514 - PASSES; ASTM E 662<450, PASSES CPT-1 CARPET: PATCRAFT McKENNER 26 OZ. (NO PAD) FOR NATIONAL PRICING CONTACT: HOWARD CARROLL; (630) 809-6867 MOBILE, (630) 527-0493 FAX, howard.carroll@patcraft.com ASTM D 2859 - PASSES; FEDERAL FLAMMABILITY STANDARD DOC FF 1-70 - PASSES RUB-1 RUBBER FLOOR; REGUPOL AKTIV AK10101 GRAY HOUND 3/8", 5% WHITE FLECK, 4' WIDE STRIPS. CONTACT: ED FOSSET; (630) 235-4011 MOBILE, (630) 357-5982 FAX, edfosset@aol.com ASTM D 2859 - PASSES; FEDERAL FLAMMABILITY STANDARD DOC FF 1-70 - PASSES PT-1 SHERWIN WILLIAMS - PROMAR 200 ZEO VOC INTERIOR LATEX - EGGSHELL - ATI RED PANTONE 485C, SALES NUMBER 650186976, CCE COLOR CAST: Y1 YELLOW 8 45 -- 1 HMIS FLAMMABILITY = 0; PT-2 PAINT: SHERWIN WILLIAMS 200 EGGSHELL - WEB GRAY SW7075 HMIS FLAMMABILITY = 0; PT-3 PAINT: SHERWIN WILLIAMS 200 EGGSHELL - GRAY MATTERS SW7066 HMIS FLAMMABILITY = 0; PT-4 PAINT: SHERWIN WILLIAMS 200 EGGSHELL - CEILING WHITE HMIS FLAMMABILITY = 0; ACT-1 2 X 4 ACOUSTICAL TILE; ARMSTRONG 755A 5/8" ASTM E84 FLAME SPREAD INDEX 25 OR LESS; ASTM E1264 TYPE III; FIRE CLASS A WP-1 FRP: GENERIC WHITE NFPA CLASS A FIRE RATING; UL - 723 PASSES; CAN/ULC-S102.2 FLAME SPREAD 15 WP-2 FRP: INPRO - SANPARREL DT SHEET - 40 / 1000" THICKNESS - 0107 PEWTER GRAY (DARK GRAY) NFPA CLASS A FIRE RATING; UL - 723 PASSES; CAN/ULC-S102.2 FLAME SPREAD 15 WP-3 FRP: INPRO - SANPARREL DT SHEET - 40 / 1000" THICKNESS - 0106 DOVE GRAY (LIGHT GRAY) NFPA CLASS A FIRE RATING; UL - 723 PASSES; CAN/ULC-S102.2 FLAME SPREAD 15 FB-1 CUBICLE CURTAIN FABRIC: IMPERIAL FASTENER COMPANY - NEW WINDSOR - COLOR: PEWTER NFPA CLASS A FIRE RATING; UL - 723 PASSES; CAN/ULC-S102.2 FLAME SPREAD 15 PLAM-1 WILSONART MISTED ZEPHYR 4843-60 ASTM E 84 - FLAME SPREAD 40; SMOKE DEVELOPED 45 PLAM-2 FORMICA WENGE STRAND 6306-58 ASTM E 84 - FLAME SPREAD 40; SMOKE DEVELOPED 45 CT-1 CERAMIC TILE: DALTILE-MZARZZI - COTTON CONTEMPO, 12" X 12" - GREY ASTM E 84, NFPA 255, UL 273 - CLASS A CT-2 CERAMIC TILE: DALTILE-MZARZZI - COTTON CONTEMPO, 3" X 12" BULLNOSE - GREY ASTM E 84, NFPA 255, UL 273 - CLASS A ROOM FINISH SCHEDULE (REFER TO WALL FINISH PLAN FOR WALL FINISHES) RM. NO. ROOM NAME BASE FLOOR CEILING NOTES 120 WAITING VB-1 VF-1 ACT-1 HALF-WALL-GYP BD. 121 RECEPTION VB-1 VF-1 ACT-1 122 TOILET VB-2 VF-1 GYP 123 HOSPITALITY VB-1 VF-1 ACT-1 124 TOILET VB-2 VF-1 GYP 125 TREATMENT VB-1 VF-1 ACT-1 126 TREATMENT VB-1 VF-1 ACT-1 127 OPEN GYM VB-1 RB-1 ACT-1 128 OPEN TREATMENT VB-1 VF-1 ACT-1 129 LAUNDRY/BREAK ROOM EXISTING EXISTING ACT-1 ATI WILL PROVIDE FLOORING MATERIALS AND LIGHTING FIXTURES 6" = 1'-0"1 FLOOR TRANSITION STRIPS 1/8" = 1'-0"2 REFLECTED CEILING PLAN 3/16" = 1'-0"3 WALL FINISH PLAN PERMIT SET 08/06/25 JLC 08/05/2025 BOBRICK B-165 24"X36" MIRROR IN SS CHANNEL FRAME, MIRROR TO BE HUNG 40" MAX A.F.F. TO BOTTOM EDGE OF REFLECTING SURFACE GRAB BAR SPEC: BOBRICK B-6806 SERIES, SATIN FINISH FLUSH LEVER ON "WIDE" SIDE OF TOILET ROOM H.C. TOILET MANSFIELD SUMMIT 1.28 384 BOBRICK B-369 PAPER TOWEL DISPESER AND DISPOSAL 2' - 3 " MA X 3' - 4 " 6" 3' - 0" 2' - 1 0 " 1' - 7"2' - 11" 3' - 4 " HC LAVATORY MANSFIELD GRANDE ISLE 2018 HBNS L1 0" NOTE: PROVIDE BLOCKING IN WALL FOR GRAB BARS 1 1/2" OD GRAB BAR 18" OD VERT GRAB BAR TPH BOBRICK B-7686 2-ROLL T.P. DISPENSER BOBRICK B-270 SANITARY NAPKIN DISPOSAL 7"-9" MI N 1' - 3 " L1 0" CENTER OF ALL 'HIGH' OUTLETS AT TREATMENT TABLES TO BE 34" AFF. TYP MOUNTED VERTICALLY (6' LINEAR) BALANCE BARRE WALL MOUNTED MIRRORS, GLUED AND SCREWED TO WALL, CENTERED ON BALANCE BARRE 5' - 0 " 3 ' - 6 1 / 8 " 6' - 0 " 2 ' - 0 " 2' - 4" 6' - 0" 2' - 11"6' - 3"3' - 5"4' - 7"1' - 9"7' - 11"4' - 1"7' - 11"4' - 1"7' - 11"3' - 0" 2' - 9 " 1 A500 SCHEDULED WALL PROTECTION 8' - 6 1 / 8 " NOTE: ALL CABINET DOOR PULLS TO BE WIRE PULLS AND SHALL NOT REQUIRE ANY PINCHING, TWISTING, OR TIGHT GRASPING NO SIDE PANEL AT SINK SKIRT 24" DEEP BASE CABINETSPOWER LOCATED BELOW COUNTER GFI OUTLET 42" AFF OPEN AREA UNDER SINK FOR ADA COMPLIANCE HALF WALL WITH PLAM CAP, SEE DETAILS 3 - A500 AND 4 - A500 5' - 10 1/2" 4' - 0 " MA X 3' - 1 0 " DATA FOR WALL PHONE, REF MEP SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T R E M O D E L Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M , W A 9 8 5 9 7 NRS INTERIOR ELEVATIONS A200 1 3/8" = 1'-0"3 RESTROOM ELEVATION 3/8" = 1'-0"4 RESTROOM ELEVATION 3/8" = 1'-0"1 OPEN TREATMENT ELEVATION 3/8" = 1'-0"2 HOSPITALITY ELEVATION PERMIT SET 08/06/25 JLC 08/05/2025 TOP VIEW PLAM CAP (PLAM-1) 7" R 6 " 7" 5 1/2"PLAM CAP 2" 3' - 6 " 3 5/8" METAL STUDS @ 16" O.C. 5/8" DW EA. SIDE VINYL BASE CONT. BOTTOM TRACK FASTENED TO SLAB PRIOR TO ANCHORING T.S. FLANGES METAL STUD CRIPPLES OF HALF- WALL SHOT TO T.S. W/ CONT. TOP TRACK 3X3 TUBE STEEL W/ 1/4" FLANGES ANCHOR BOLTED TO SLAB FRONT ELEVATION BALANCE BARRE ESCUTCHEON PAINT EXPOSED DRYWALL TO MATCH ADJACENT WALL 1/4" POLISHED PLATE GLASS MIRRIOR, FRAMELESS & GLUED TO WALL WITH SAFETY BACKING PROVIDE OPENING/ CUTOUT IN MIRRORS FOR BARRE BRACKETS, CONFIRM LOCATIONS OF BRACKETS WITH BARRE MANUFACTURER, PROVIDE ESCUTCHEON OVER MIRROR OPENING, MATCH FINISH OF BARRE BRACKETS VITA-VIBE PROFESSIONAL ALUM. SINGLE BAR WALL MOUNT BALLET BARRE SYSTEM, SEE PLANS FOR ACTUAL LENGTH OF PROPOSED BARRE 2X10 BLOCKING FASTENED BETWEEN STUDS MIRROR SITS 2'-0" A.F.F. SCHEDULED BASE 3' - 6 " SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T R E M O D E L Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M , W A 9 8 5 9 7 NRS DETAILS A500 1 3/4" = 1'-0"2 HALF-WALL DETAIL NTS3HALF-WALL STANCHION 3/4" = 1'-0"1 BALANCE BARRE DETAIL CABINETRY NOTES DRAWER SLIDES - SMALL DRAWWERS - KV8400 DRAWER SLIDES - FILE DRAWWERS - KV8500 HINGES ARE BLUM 170 DEGREE OPENING PULLS ARE BRUSHED ALUMINUM FINISH CABINETS ARE 3/4" CONSTRUCTION W/ 1/2" BACKS SHELVES ARE 3/4" CONSTRUCTION W/ PVC EDGING ALL COUNTERTOPS - PLAM-1 ALL TRANSACTION COUNTERS - PLAM-1 ALL CABINETS - PLAM-2 ALL CABINET INTERIORS - WHITE MELAMINE FINISH PROVIDE 4" BACKSPLASH AT ALL COUNTERS AND CORNER SHELVES NO KEYBOARD SHELVES IN PROJECT, TYP. THROUGHOUT GRAIN OF PLAM-2 TO RUN VERTICALLY ON ALL SURFACES ALL GROMMETS TO BE LIGHT GRAY CAULK BACKSPLASHES AT COUNTER TOP SEAM AND WALL SEAM (CLEAR CAULK) PERMIT SET 08/06/25 JLC 08/05/2025 SIDE 1 PARTITION TYPE SIDE 1 PARTITION TYPE 3 (CAVITY WALLS) METAL STUD FRAMING SIDE 1 3A VARIES ------ -W.R. SIDE 2 5/8" W.R. 5/8"3 5/8" 16" O.C.MIN. 25GA SEE NOTE D 2A 4 7/8" 2B 2C 2D 7 1/4" 2E 2F 2G 2H 2J 2K - - 1 HOUR 1 HOUR - - 1 HOUR 1 HOUR - - - - UL U465 UL U465 - - UL U465 UL U465 - - - - - - - - - - - - - - 'X' 'X' WR WR WRX 'X' 'X' PARTITION TYPE 2 (TYPICAL PARTITIONS) METAL STUD FRAMING GYPSUM BOARD 1A 1B THK 4 1/4" 1 1/2" 1C 1D 1E FIRE RATING - - - - - - - - - - - - - - - - - - - - TYPE PARTITION TYPE 1 (FURRED PARTITIONS) METAL STUD FRAMING GYPSUM BOARD SIDE 2 GYPSUM BOARD SIDE 1 THK - - - - - SIDE 2 TYPE -- -- -- WR WR THK 5/8" 5/8" 5/8" 5/8" 5/8" SIZE 3 5/8" 7/8" 2 1/2" 3 5/8" 6" SPACING 16" O.C. 16" O.C. 16" O.C. 16" O.C. GAUGE MIN. 25GA MIN. 25GA MIN. 25GA MIN. 25GA MIN. 25GA SEE NOTE B SEE NOTE B SIDE 2 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" WRX 5/8" 5/8" - - 'X' 'X' 5/8" 5/8" 5/8" 5/8" WR WR 5/8"WRX WRX 5/8" 5/8" WRX WRX 3 5/8" 6" 3 5/8" 6" 3 5/8" 6" 3 5/8" 6" 3 5/8" 6" 16" O.C. MIN. 25GA FRAMING NOTES SEE NOTE A SEE NOTE A SEE NOTE B SEE NOTE B SEE NOTE C SEE NOTE C SEE NOTE E SEE NOTE E INSULATION - (INDICATED ON PLANS W/ SW FOR SOUND WALL OR TW FOR THERMAL WALL - BATTS) STC RATING TEST NUMBER 16" O.C. VERTICAL SOUND INSULATION- (INDICATED ON PLANS W/ SW FOR SOUND WALL) GYPSUM BOARD. (WATER RESISTANT ON TOILET SIDE) SOUND INSULATION- (INDICATED ON PLANS w/ SW FOR SOUND WALL) STUD @ 1/3 POINTS 48" O.C. MAX @ TYPE 3C 3 1/8" 4 1/4" 6 5/8" PARTITION TYPE THK FIRE RATING TYPE GYPSUM BOARD SIDE 1 THK SIDE 2 TYPE THK SIZE SPACING GAUGE FRAMING NOTES STC RATING TEST NUMBER 4 7/8" 7 1/4" 4 7/8" 7 1/4" 4 7/8" 7 1/4" 4 7/8" 7 1/4" 5/8" 5/8" 5/8" 5/8" 16" O.C. 16" O.C. 16" O.C. 16" O.C. 16" O.C. 16" O.C. 16" O.C. 16" O.C. 16" O.C. MIN. 25GA MIN. 25GA MIN. 25GA MIN. 25GA MIN. 25GA MIN. 25GA MIN. 25GA MIN. 25GA MIN. 25GA PARTITION TYPE THK FIRE RATING TYPE GYPSUM BOARD SIDE 1 THK SIDE 2 TYPE THK SIZE SPACING GAUGE FRAMING NOTES STC RATING TEST NUMBER FIRE-RESISTANT RATED PARTITIONS FRAMING VAPOR BARRIER GYPSUM BOARD 1. All partitions indicated to be fire rated shall be constructed in strict accordance with the referenced fire resistance test. If no test is referenced, an industry recognized fire resistance test shall be used. 2. Fire resistant rated partitions shall extend from floor to structural deck above. 3. Approved fire-resisitive materials must be used at all penetrations through fire rated assemblies. 1. Gypsum board shall be installed per ASTM C 840. 2. Install water resistant gypsum board at plumbing chase walls, within all toilet rooms, janitor closets and all wet areas- see plans. 3. Finish all corners and exposed edges of gypsum board with taped-in metal trim accessories. Use exposed trim only when specifically indicated. 4. Gypsum board partitions shall be taped and sanded smooth with no visible joints. 5. Recessed items shall be installed flush with partition (U.O.N.) . Partition depth shall be adjusted to accommodate depth of recessed item. 6. All remaining existing walls and walls affected by demo to be patched and or skim coated for paint finish or laminated with 1/4" gypsum board for smooth paint finish, contractors option. 1. Provide 6 mil Poly Vapor Barrier over mtl. studs & insulation at all exterior wall furring as shown on plan. 1. All load bearing partitions shall be constructed per structural drawings and specifications. 2. All non-bearing partitions shall be constructed to limit deflection per building code restrictions and mfr's, whichever is greater. Chase walls shall resist loads perpendicular to shaft. 3. Provide double framing at jambs of frames and cased openings. 4. Screw attach studs to runner track at both sides. 5. Isolate non-bearing framing from structural elements slip connections to prevent the transfer of loads to partition framing. 6. Control joints shall be installed at 30'-0" o.c. (maximum) and at major interruptions in the wall - ie doors, windows and equipment. See elevations and plans for locations and verify locations with Architect. 7. Provide fire retardant blocking for all wall mounted architectural woodwork, finish carpentry, toilet partitions and accessories, railings, shelving and similar mounted items. For mounting heights see interior elevations. 8. Cross bracing at all chase wall framing to be 12" high, 1/2" gyp. bd. or min. 2 1/2" metal studs at 1/3 pts. 9. Framing shall coordinate with all required mechanical, electrical, plumbing, fire protection, data and other related work. 10. Provide approved fire stopping materials at the ceiling plane in partitions which penetrate the ceiling. 11. Top of wall shall be constructed as follows: S - to structural deck T - thru ceiling U - to underside of ceiling PARTITION GENERAL NOTES SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T R E M O D E L Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M , W A 9 8 5 9 7 NRS WALL DETAILS, NOTES, & SCHEDULES A600 1 PARTITION TYPE NOTES A. PROVIDE HEAD OF WALL ASSEMBLY HW-D-0060 B. WR = WATER RESISTANT GYMPSUM BOARD C. WRX = WATER RESISTANT/FIRE RATED GYPSYM BOARD D. WHEN PVC PIPE IS USED, CHASE MUST EITHER BE CAPPED OR PARTITIONS MUST EXTEND TO DECK ABOVE E. WALL TO BE CONSTRUCTED IN A MANNER CAPABLE OF RESISTING THE PASSAGE OF SMOKE. SEAL ALL PENETRATIONS THROUGH WALL. PERMIT SET 08/06/25 JLC 08/05/2025 2A S PARTITION TYPE SOUND INSULATION - SEE PLANS FOR LOCATIONS -INDICATED BY "SW". FLOATING CONSTRUCTION- SEE 4-A601 (@ PERIMITER PROVIDE FIRE SEALANT @ FIRE-RATED PARTITIONS & SEALANT @ SOUND WALLS) EXTEND PARTITION TO UNDERSIDE OF DECK ABOVE SEISMIC BRACING AS REQ'D. FINISH CEILING-SEE SCHEDULE FIRE BLOCKING AS REQ'D. PARTITION HEIGHT-TO UNDERSIDE OF STRUCTURE BASE AND FINISH FLOOR AS SCHEDULED 2A T PARTITION TYPE ALTERNATE METAL STUD KICKERS @ 48" O.C.- ATTACH TO STRUCTURE W/ (2) POWER-ACTUATED FASTENERS PER KICKER SOUND INSULATION - SEE PLANS FOR LOCATIONS -INDICATED BY "SW". PROVIDE INSULATION @ CLG. 48" EACH DIRECTION FROM SOUND WALL SEISMIC BRACING AS REQ'D. FINISH CEILING-SEE SCHEDULE DRYWALL TO STOP 6" ABOVE CEILING FIRE BLOCKING AS REQ'D. TAPABLE J-MOLD @ T.O. PARTITION PARTITION HEIGHT- THRU CEILING BASE AND FINISH FLOOR AS SCHEDULED 2A C PARTITION TYPE BASE AND FINISH FLOOR AS SCHEDULED PARTITION HEIGHT- UNDERSIDE OF CEILING TAPABLE J-MOLD @ T.O. PARTITION ANCHOR TOP TRACK TO CEILING GRID FINISH CEILING-SEE SCHEDULE BRACING AS REQ'D. METAL CLOSER TRACK RATED PARTITION RATED ASSEMBLY MUST EXTEND TO DECK - IF SYSTEM IS INTERRUPTED BY BEAM/JOIST, WRAP SYSTEM AROUND STRUCTURE AND EXTEND TO DECK FIRE SEALANT (BOTH SIDES) REFER TO UL ASSEMBLY HW-D-0060. SCHEDULED RATED PARTITION. SEE PLANS FOR PARTITION TYPE. 1 1 / 2 " 2" SCHEDULED PARTITION. 2 NESTED STUDS H.M. FRAME SEALANT EA. SIDE JAMB ANCHOR 3 PER SIDE SEE SCHEDULE FOR DOOR TYPE 1/2"1/2" 5" SE E S C H E D . SCHEDULED PARTITION. SEE SCHEDULE FOR DOOR TYPE HM FRAME WITH SEALANT AT EACH SIDE 5" 1/2"1/2" SE E S C H E D . A B C D E DOOR FRAME TYPES 2" 2" 6 A601 5 A601 PTD. HOLLOW METAL FRAME 2" PTD. HOLLOW METAL FRAME SS KICK PLATE FULL WIDTH A B C D E SS KICK PLATE FULL WIDTH TO MATCH BUILDING STANDARD TEMP. 2" PTD. HOLLOW METAL FRAME LOUVER 12" X 24" DOOR TYPES SET 1 HARDWARE SETS SET 2 SET 3 SET 4 SET 5 • EXISTING HINGES • NEW WEATHER STRIPPING • 1 SURFACE MOUNTED CLOSER • 1 SET EXIT/ENTRANCE LEVER LOCK (AL53PD) • 1 1/2 PR BUTT HINGES - BB • 1 PASSAGE LEVER SET (AL10S) • 1 WALL STOP • SILENCER ON DOOR FRAME • 1 1/2 PR BUTT HINGES - BB • 1 PRIVACY LEVER SET (AL40S) • 1 WALL STOP • 1 KICK PLATE (PUSH SIDE) • 1 ROOM IDENTIFICATION SIGN • 1 HANDICAP EMBLEM • SILENCER ON DOOR FRAME • 1 1/2 PR BUTT HINGES - BB • 1 PASSAGE LEVER SET (AL10S) • 1 WALL STOP • 1 KICK PLATE (PUSH SIDE) • 1 SURFACE MOUNTED CLOSER • SILENCER ON DOOR FRAME • KNURLED DETECTABLE HARDWARE • 1 1/2 PR BUTT HINGES - BB • 1 SURFACE MOUNTED CLOSER • SILENCER ON DOOR FRAME • EXIT LEVER LOCK 1/2" 11' - 10 1/2" 1/2" 12' - 0" 1' - 0 " 3 ' - 6 " 1' - 0 " 1 1 / 2 " 3 ' - 4 1 / 2 " 12 A601 3/4" THICK SIDE PANEL AND BACKSPLASH TO BE PLAM-2. RUN PATTERN VERTICALLY 1-1/2" COUNTERTOP TO BE PLAM-1 (2) GIBRALTAR H-BASE LEGS #AHB-2214 PROVIDE (4) LEVELERS (IEC - IL98-4GX2-H-P) AT ALL LEG ENDS, ATTACHED TO FLOOR W/ TAPCON OR SIM FASTENING SYSTEM W/ PANHEAD TO ENSURE FLUSH INSTALLATION. ENSURE FASTENING IS BLACK PROVIDE POWER DISTRIBUTION UNIT; LEGRAND RDZ - BLACK (2) HEAVY DUTY L-BRACKET, KNAPE & VOGT SUPER-DUTY ULTIMATE L-BRACKET (OR SIM) PROVIDE BLOCKING IF NEEDED, EXPOSED BLOCKING TO BE LAMINATED 10 A601 1-1/2" COUNTERTOP TO BE PLAM-1 (2) GIBRALTAR H-BASE LEGS #AHB-2214 3/4" THICK SIDE PANEL AND BACKSPLASH TO BE PLAM-2 (2) HEAVY DUTY L-BRACKET, KNAPE & VOGT SUPER DUTY ULTIMATE L-BRACKET (OR SIM) PROVIDE BLOCKING IF NEEDED, EXPOSED BLOCKING TO BE LAMINATED 1/2" 11' - 10 1/2" 1" 1/ 2 " 2 ' - 0 " 2' - 1 " 12' - 0" 1 1 / 2 " PROVIDE POWER DISTRIBUTION UNIT; LEGRAND RDZ - BLACK NOTE: SECURE WIRE FROM POWER DISTRIBUTION UNIT TO UNDERSIDE OF TABLE VIA WIRE MANAGMENT CLIPS/ HOOKS. PROVIDE POWER STRIP AS NEEDED (SECURE TO UNDERSIDE OF DESK) TO EXTEND POWER WIRE OR ALLOW FOR MULTIPLE UNITS. DESK TO BE CLEAR OF ANY HANGING WIRES 3/4" THICK SIDE PANEL AND BACKSPLASH TO BE PLAM-2. RUN PATTERN VERTICALLY 1-1/2" COUNTERTOP TO BE PLAM-1 (2) GIBRALTAR H-BASE LEGS #AHB-2214 PROVIDE (4) LEVELERS (IEC - IL98-4GX2-H-P) AT ALL LEG ENDS, ATTACHED TO FLOOR W/ TAPCON OR SIM FASTENING SYSTEM W/ PANHEAD TO ENSURE FLUSH INSTALLATION. ENSURE FASTENING IS BLACK (2) HEAVY DUTY L-BRACKET, KNAPE & VOGT SUPER-DUTY ULTIMATE L-BRACKET (OR SIM) PROVIDE BLOCKING IF NEEDED, EXPOSED BLOCKING TO BE LAMINATED OUTLET TO BE 30" A.F.F. CENTERED WITH HOSPITALITY TABLE PROVIDE A CLEAN CUTOUT IN SIDE SKIRT FOR OUTLET 1' - 0 " 3 ' - 6 " 4' - 6 " 1/2" 2' - 0" 1' - 0 " 3' - 4 1 / 2 " 3' - 6 " 1' - 0" 10 " SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T R E M O D E L Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M , W A 9 8 5 9 7 NRS WALL DETAILS, DOOR DETAILS, & SCHEDULES A601 1 DOOR NUMBER ROOM NAME DOOR FRAME HARDWARE FIRE RATING NOTES DOOR NUMBERTYPESIZEFINISH TYPE DETAIL FINISHWIDTH HEIGHT THICKNESS HEAD JAMB 127 TOILET B 3' - 0" 6' - 8" 0' - 1 3/4" S.C. WD - PREFINISHED, SEE NOTE 1 A 6 5 H.M. PT-2 3 -- SEE NOTE 16 124 NTS1TYP. WALL DETAIL NTS2TYP. WALL DETAIL NTS3TYP. WALL DETAIL NTS4SLIP JOINT DETAIL NTS5TYP. JAMB DETAIL NTS6TYP. HEAD DETAIL DOOR GENERAL NOTES 1. ALL DOOR TO MATCH GRAHAM PLAIN SLICED BLACK WALNUT; CACTUS #425 2. ALL HARDWARE TO BE SCHLAGE AL-SERIES W/ ROCKWOOD WALL BUMPERS, & STANLEY FIVE KNUCLE HINGES (OR APPROVED EQUAL) 3. CONCAVE WALL STOP TO BE: HAGER 236W; US26D FINISH 4. PROVIDE STOPS AS REQUIRED FOR BYPASS SLIDING DOOR HARDWARE 5. DOOR HANDLES TO BE: SCHLAGE AL-SERIES "SATURN" 626 6. CLOSER TO BE: YALE 3500/3501/3501 BF SERIES 7. ALL DOORS SHALL BE MANUF. OR FIELD CUT TO CLEAR FLOOR FINISHES 8. ALL EXTERIOR DOORS SHALL BE INSULATED 9. ALL HARDWARE ON ALUM. DOORS SHALL 10. MIN. 3 SILENCERS PER DOOR 11. HINGES FOR EXTERIOR DOORS AND OUT-SWINGING INTERIOR DOORS SHALL HAVE NON-REMOVABLE PINS 12. MAXIMUM OPENING FORCE FOR EXTERIOR HINGED DOORS IS 8.5 LBF; INTERIOR HINGED DOORS NOT TO EXCEED 5 LBF, AND SLIDING OR FOLDER DOORS NOT TO EXCEED 5 LBF 13. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX A.F.F. WHERE SLIDING DOORS ARE IN THE FULLY OPEN POSITION, OPERATING HARDWARE SHALL BE EXPOSED AND USABLE FROM BOTH SIDES. 14. VERIFY CONDITION OF EXISTING DOORS & HARDWARE. PROVIDE ALLOWANCE TO REPLACE. IF EXISTING DOOR IS TO REMAIN, REPAIR ANY DAMAGE TO DOOR TO PROVIDE SMOOTH FLAT PAINT FINISH, REPAIR/ REPLACE ANY WEATHER STRIPPING, HINGES, CLOSER, OR SWEEP. 15. INSTALL CONTACT-ACTIVATED OR MOTION-ACTIVATED DOOR CHIME AT FRONT DOOR 16. DOOR CLOSER BOLTS NOT TO PENETRATE THROUGH DOOR, PROVIDE BLOCKING IN DOOR AS REQUIRED 3/4" = 1'-0"10 HOSPITALITY TABLE ELEVATION 3/4" = 1'-0"11 HOSPITALITY TABLE PLAN 3/4" = 1'-0"12 HOSPITALITY TABLE SECTION ATI WILL PROVIDE FLOORING MATERIALS AND LIGHTING FIXTURES PERMIT SET 08/06/25 JLC 08/05/2025 SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 RPH ENERGY COMPLIANCE ANALYSIS ECA100 1 JMP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 PERMIT SET 08/06/25 08.06 .2025 TV SP SPSPSP ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETRETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETRETR ETR ETR ETR ETR ETR ETRETRETR ETR ETR ETRETRETRETRETR ETR ETR ETRETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETRETR ETR ETR ETR ETR ETR L H ETR ETR ETR ETRETR ETR DE01 (TYP) SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 RPH FLOOR PLAN -ELECTRICAL DEMOLITION DE100 1 JMP SCALE:1/4" = 1'-0" FLOOR PLAN - ELECTRICAL DEMOLITION FLOOR PLAN NOTESDE 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 DE01 REMOVE INTERIOR ELECTRICAL DEVICES INCLUDING BUT NOT LIMITED TO RECEPTACLES, LIGHTING FIXTURES, LIGHTING SWITCHES, DATA DEVICES, FIRE ALARM DEVICES, ETC. ALL ASSOCIATED JUNCTION BOXES, CONDUCTOR, AND CONDUIT SHALL BE REMOVED TO NEAREST DEVICE TO REMAIN. (U.NO.) TURN ALL UN-USED CIRCUIT BREAKERS OFF AND PROVIDE BLANK OFF-PLATES ON ALL OPEN UN-USED POLE SPACES.NPERMIT SET 08/06/25 08.06 .2025 SP SPSPSP (E) TREATMENT 126 (E) TREATMENT 125 TOILET 124 (E) TOILET 122 HOSPITALITY 123 OPEN GYM 127 (E) LAUNDRY/BREAK ROOM 129 (E) MECH 130 (E) WAITING 120 RECEPTION 121 (E) OPEN TREATMENT 128 ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETRETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETRETRETRETRETRETRETR ETR ETR ETR ETR ETR ETR ETRETRETR ETRETRETRETRETR ETR ETR ETR ETRETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR ETR L H 10 L ETR ETR ETR ETR ETRETR ETR ETR ETR ETR ETR ETR E02 E03 ETR ETR ETR ETR ETR ETR ETR ETR ETR 90" 34" 34" 34" 21 L E04 (TYP3) 90" E05 SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 RPH FLOOR PLAN -POWER & SYSTEMS E100 1 JMP SCALE:1/4" = 1'-0" FLOOR PLAN - POWER & SYSTEMS FLOOR PLAN NOTESE 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 E02 EXTEND CIRCUITRY TO RELOCATED FIRE ALARM DEVICE. E03 CIRCUIT AND CONTROL EXISTING RELOCATED EXHAUST FAN SERVING RESTROOM TO LIGHTING CONTROLS SERVING RESTROOM. COORDINATE WITH MECHANICAL CONTRACTOR AS NECESSARY. E04 TREATMENT TABLE RECEPTACLE. COORDINATE EXACT LOCATION WITH ARCHITECT. E05 RECEPTACLE AND DATA FOR TV. COORDINATE LOCATION WITH ARCHITECT PRIOR TO INSTALL.NPERMIT SET 08/06/25 08.06 .2025 MS DS MS DS LVD LVD MS LV D 2 LV D 2 LVD DC DC2 DC DC MS DC2 DC2 MS MS MS MS MS MS MSMS MS (E) TREATMENT 126 (E) TREATMENT 125 TOILET 124 HOSPITALITY 123 OPEN GYM 127 (E) OPEN TREATMENT 128 OPEN GYM 127 (E) LAUNDRY/BREAK ROOM 129 RECEPTION 121 (E) WAITING 120 ETR L H (E) TOILET 122A1E A1 A1E A1 A1E A1 A1 A1 A1 A1E A1 A1 A1E A1 A1 A1 A1 A1 A1 A1E A1 A1 A1E A1A1 A1 A1A1EA1 A1 A1E A1 A1 A1 A1 A1 B B B B X X B A1E A2 A2 C C PRIMARY SIDELIT ZONE SECONDARY SIDELIT ZONE PRIMARY SIDELIT ZONE SECONDARY SIDELIT ZONE 1 H E01 (TYP) E01 (TYP) EM EM EM EM EM EM EM EM EM EM EM SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 RPH FLOOR PLAN -LIGHTING E200 1 JMP FLOOR PLAN NOTESE 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 SCALE:1/4" = 1'-0" FLOOR PLAN - LIGHTING E01 CONNECT EXIT SIGNS AND BUG EYES TO THE HOT LEG OF THE NEAREST LIGHTING CIRCUIT.NPERMIT SET 08/06/25 08.06 .2025 E E E E CKT # 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 CIRCUIT DECRIPTION LTG VAV-3 VAV-6 VAV-5 SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY NOTES: E = EXISTING CIRCUIT BREAKER *REFER TO THE BRANCH CIRCUIT COPPER CONDUCTOR AND CONDUIT SIZING CHART FOR SIZING BRANCH CIRCUITS OF 100A OR LESS PANELBOARD H BUS AMPS: MAIN SIZE / TYPE: VOLTS/PHASE: SECTION: 225A MLO 480Y/277V, 3PH, 4W 1 CB AMPS 20 20 15 15 P 1 3 3 3 LOAD VA 600 4,000 4,000 4,000 3,000 3,000 3,000 3,000 3,000 3,000 0 0 0 0 0 PER PHASE CONNECTED - VA PER PHASE CONNECTED - AMPS SCCR: NEMA TYPE: MOUNTING: LOCATION: A VA 600 8,000 7,000 6,000 0 21,600 78 EXISTING 1 SURFACE ATI ELEC CLOSET B VA 8,000 7,000 6,000 0 0 21,000 76 C VA 8,000 7,000 6,000 0 0 21,000 76 FULLY RATED LOAD VA 0 4,000 4,000 4,000 4,000 4,000 4,000 3,000 3,000 3,000 0 0 0 0 0 P 3 3 3 TYPE: MANUFACTURER: MFG MODEL: OPTIONS: CB AMPS 20 20 15 BRANCH CIRCUIT PANELBOARD EATON CIRCUIT DECRIPTION SPACE ONLY VAV-1 VAV-2 VAV-4 SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY TOTAL CONNECTED - VA TOTAL CONNECTED - AMPS TOTAL DEMAND - VA NEC TOTAL DEMAND - AMPS 63,600 76 63,750 77 CKT # 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 E E E E E E E E E E E E CKT # 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 CIRCUIT DECRIPTION HYDROCULATOR RCPT - DOCK STATION 2 RCPT - EXAM ROOM RCPT - OFFICE RCPT - GYM LTG - EXAM ROOM RCPT - RECEPTION RCPT - EXAM ROOM WATER HEATER SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY NOTES: E = EXISTING CIRCUIT BREAKER *REFER TO THE BRANCH CIRCUIT COPPER CONDUCTOR AND CONDUIT SIZING CHART FOR SIZING BRANCH CIRCUITS OF 100A OR LESS PANELBOARD L BUS AMPS: MAIN SIZE / TYPE: VOLTS/PHASE: SECTION: 225A MLO 208Y/120V, 3PH, 4W 1 CB AMPS 20 20 20 20 20 20 20 20 30 P 1 1 1 1 1 1 1 1 2 LOAD VA 1,000 720 720 720 1,080 1,500 720 360 1,500 1,500 0 0 0 0 0 0 0 0 0 0 0 PER PHASE CONNECTED - VA PER PHASE CONNECTED - AMPS SCCR: NEMA TYPE: MOUNTING: LOCATION: A VA 3,000 1,440 1,440 2,220 0 0 0 8,100 68 EXISTING 1 FLUSH ATI ELEC CLOSET B VA 2,720 1,080 1,360 0 0 0 0 5,160 43 C VA 1,720 2,220 2,220 0 0 0 0 6,160 51 FULLY RATED LOAD VA 2,000 2,000 1,000 720 0 720 720 1,000 720 720 0 0 0 0 0 0 0 0 0 0 0 P 2 1 1 1 1 1 1 1 1 TYPE: MANUFACTURER: MFG MODEL: OPTIONS: CB AMPS 30 20 20 20 20 20 20 20 20 BRANCH CIRCUIT PANELBOARD EATON CIRCUIT DECRIPTION DRYER WASHER RCPT - DOCK STATION SPARE RCPT - WORK ROOM 1 RCPT - WORK ROOM 2 RCPT - COPIER RCPT - RECEPTION RCPT - PHONEBOARD SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY SPACE ONLY TOTAL CONNECTED - VA TOTAL CONNECTED - AMPS TOTAL DEMAND - VA NEC TOTAL DEMAND - AMPS 19,420 54 20,545 57 CKT # 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 E E E E E E E E E FIXTURE AS SPECIFIED. WHERE FACTORY INSTALLED BATTER/INVERTER UNITS ARE INSTALLED, A NON-SWITCHED CIRCUIT WIRE WILL BE CONNECTED TO THE INVERTER. 3/4" MIN. FLEX CONDUIT MAXIMUM 6' LENGTH TO CIRCUIT RACEWAY J-BOX ATTACHED TO STRUCTURE ABOVE #12GA SUPPORT WIRES TIED TO EACH FIXTURE CORNER MIN. 3 TIGHT TURNS AROUND SELF (TYP) ACOUSTIC TILE CEILING AND T-BAR GRID SS T OR PLAN VIEW OFFSER CONDUIT TO ALLOW FOR VERTICAL ALIGNMENT OF DEVICES (TYPICAL) COMBINATION HORN/STROBE LIGHT THERMOSTAT LIGHT SWITCH DUPLEX RECEPTACLE FOURPLEX RECEPTACLE COMMUNICATION OUTLET FLOOR NOTE: ALIGN ALL DEVICES VERTICALLY. IF ANY DEVICE(S) ARE FOUND NOT TO BE INSTALLED PER DETAIL, CONTRACTOR SHALL RELOCATE AND PAY ALL ASSOCIATED COST ASSOCIATED WITH THE RELOCATION(S). 1' - 6 " 3' - 1 0 " 6' - 8 " CEILING USE ADJACENT CUT-OUTS WHEN MOUNTING DATA/PHONE AND RECEPTACLE DEVICES TOGETHER PLAN VIEW CEILING FLOOR COMMUNICATION OUTLET RECEPTACLE MOUNT OUTLET DEVICES TO SAME FRAMING STUD FRAMING STUD (TYP) UNLESS OTHERWISE NOTED ON THE DRAWINGS.=* 90 100 1 AWG 2 AWG 1-1/4" 8 AWG 8 AWG 1" 1-1/2" 1-1/4" 1-1/2" 1-1/4" 1-1/2" 1-1/4" CONDUCTOR SIZE BRANCH CIRCUIT COPPER CONDUCTOR 80 70 60 50 40 45 35 4 AWG 6 AWG 4 AWG 3 AWG 8 AWG 6 AWG 8 AWG OVERCURRENT PROTECTION DEVICE RATING (AMPS) 30 25 15 20 12 AWG 12 AWG 10 AWG 10 AWG SIZE CONDUCTOR REQUIRED 3/4" 3/4" 3/4" 3/4" 8 AWG 8 AWG 10 AWG 10 AWG 1" 1" 1" 10 AWG 10 AWG 10 AWG 1-1/4" 1" 3/4" 1" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" WIRE + GND. SINGLE PHASE 2 CONDUIT SIZE AND CONDUIT SIZING CHART 10 AWG 10 AWG 12 AWG 12 AWG EQUIPMENT GROUNDING 3/4" 3/4" 3/4" 3/4" CONDUIT SIZE SINGLE PHASE 3 WIRE + GND. 3/4" 1-1/4" 1" 1" 3/4" 3/4" 3/4" 1-1/4" 1-1/4" 1-1/4" 1" 3/4" 1" 3/4" THREE PHASE 4 3/4" 3/4" 3/4" 3/4" THREE PHASE 3 CONDUIT SIZE WIRE + GND. 3/4" 3/4" 3/4" 3/4" WIRE + GND. CONDUIT SIZE * =*ALL CONDUCTORS SIZED ON THE POWER RISER DIAGRAM OR IN BRANCH CIRCUIT CONDUCTOR TABLE ARE BASED ON 3 CURRENT CARRYING CONDUCTORS IN A RACEWAY OR CABLE. CONDUCTORS SHALL BE DERATED IN ACCORDANCE WITH THE NEC IF 4 OR MORE CONDUCTORS ARE PLACED IN A RACEWAY OR CABLE. UNLESS OTHERWISE NOTED ON THE DRAWINGS, ALL BRANCH CIRCUITS AND FEEDERS TO BE PROVIDED WITH A NEUTRAL WIRE.=* LMRC SERIES Relay On/Off/0-10V Dimming Room Controller LMLS-500 Photosensor Red NEUTRAL - WHITE/GRAY Yel Blu Lighting Load (a) Additional Lighting Load (Per Plans) (b) Vio Gry Vi o Gr y Class 2 0-10 Volt Control Wiring 0-10V DIMMING INDICATED PROVIDE UNIVERSAL DIMMING ROOM CONTROLLER FOR LINE VOLTAGE DIMMING DRIVERS LMRJ Series Pre-Terminated Cables or CAT5e. Free Topology & Splitter Acceptable HOT - BLACK LMRJ-C8 Coupler Ground GREEN Vi o Gr y Vio Gry Vio Gry Vi o Gr y Additional Lighting Load (Per Plans) (c) RJ45 (Typical) 120/277V LTG CKT WATTSTOPPER LMDC-100 CEILING SENSOR LMDM LMSW WATTSTOPPER LMDM & LMSW Series DLM Wall Switches NOTES: 1. DEVICES AND CONNECTIONS INDICATED ARE FOR SCHEMATIC PURPOSES ONLY. REFER TO PLANS, DETAILS AND LIGHTING CONTROL SCHEDULE FOR ADDITIONAL INFORMATION. PROVIDE DEVICES, CABLING AND CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATIONAL SYSTEM. 2. INSTALL ROOM CONTROLLER IN ACCESSIBLE SPACE ABOVE DOOR/ENTRY INTO THE SPACE SERVED. IN ROOMS WITH NON-ACCESSIBLE CEILING, INSTALL DEVICES IN NEARBY ADJACENT AREA WITH ACCESSIBLE CEILING SPACE. INDICATE LOCATION ON AS-BUILT DRAWINGS. 3. PROVIDE SETUP AND PROGRAMMING OF THE SYSTEM. 4. PROVIDE COMMISSIONING FUNCTIONAL TESTING AND DOCUMENTATION AS REQUIRED. SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 RPH ELECTRICAL DETAILS & SCHEDULES E300 1 JMP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 NOT TO SCALE LIGHT FIXTURE MOUNTING AND BRACING DETAIL NOT TO SCALE TYPICAL WALL MOUNTING DEVICE DETAIL NOT TO SCALE TYPICAL MOUNTING OUTLET DETAIL NOT TO SCALE TYPICAL DLM LIGHTING CONTROL DETAIL PERMIT SET 08/06/25 08.06 .2025 LIGHT FIXTURE SCHEDULE TYPE A1 (A1E) A2 (A2E) B (BE) C EM X SPECIFIC NOTES: 1 SUBSTITUTION NOTES: THE LIGHTING DESIGN FOR THIS PROJECT IS BASED UPON THE MANUFACTURERS SPECIFIED. IF AN ADDITIONAL SUBSTITUTION IS DESIRED BY THE CONTRACTOR, A SUBSTITUTION REQUEST SUBMITTAL MUST BE PROVIDED AS FOLLOWS: S1. S2. S3. S4. S5. S6. GENERAL NOTE: G1. G2. MANUFACTURER MODEL # SATCO LIGHTING NUVO 65-572 SATCO LIGHTING NUVO 65-571 GOTHAM IVO6-D-15LM-35K-80CRI-WD-MIN10-MVOLT- ZT-NCH-P-AR-LSS-F LITHONIA FMVTSL-24IN-MVOLT-30K-90CRI-BN EXITRONIX LED-95-WH EXITRONIX VLEDC-51-WH-R4 ALL LIGHTING MUST BE PURCHASED FROM CED NATIONAL ACCOUNTS. CONTACT DAVID RASH. NATIONAL ACCOUNTS REPRESENTATIVE: (817) 252-4014, DAVID.RASH@CED.COM. SUBSTITUTION REQUEST MUST BE RECEIVED BY THE ENGINEER IN WRITING 10 DAYS PRIOR TO BID. FAILURE TO SUBMIT CONSTITUTES A GUARANTEE TO SUPPLY THE SPECIFIED FIXTURES. INFORMATION IS TO BE SUPPLIED COMPARING PHOTOMETRY, (WITH FLOOR PLANS INDICATING POINT BY POINT CALCULATIONS) DIMENSIONS, MATERIAL COMPOSITION, FINISH, VISUAL APPEARANCE AS WELL AS THE "CONTRACTOR NET" PRICING. SAMPLES ARE TO BE PROVIDED UPON REQUEST. GREAT CARE, TIME AND EXPENSE HAVE BEEN USED TO PROVIDE OUR CLIENT WITH THE LIGHTING AND CONTROLS SYSTEM. THEREFORE, FOR EACH AND EVERY TYPE OF FIXTURE OFFERED AS AN UNSOLICITED ALTERNATE, A $500.00 FEE WILL BE CHARGED TO THE CONTRACTOR FOR REVIEW OF THE ALTERNATE FIXTURE. THIS CHARGE IS IN NO WAY A GUARANTEE OF APPROVAL, BUT IS SOLELY TO COMPENSATE THE ENGINEER FOR TIME SPENT VALIDATING EQUALITY AND COMPATIBILITY WITH THE PROJECT REQUIREMENTS. THIS REIMBURSEMENT MUST BE RECEIVED BY THE ENGINEER PRIOR TO ANY REVIEW COMMENCING. PACKAGING OF LIGHT FIXTURES WILL NOT BE CONSIDERED OR APPROVED. MANUFACTURER'S REPRESENTATIVE AGENTS SHALL BE ALLOWED TO OFFER MINI-LOT PRICING FOR SPECIFIED LIGHTING FIXTURES. LIGHTING CONTROLS PRICING SHALL BE COMPLETELY SEPARATE OF ANY LIGHT FIXTURE PRICING. ANY LIGHTING CONTROLS PRICING THAT IS SUBMITTED WITH LIGHT FIXTURE PRICING (UNIT OR MINI-LOT) WILL BE IMMEDIATELY REJECTED IN ITS ENTIRETY. ELECTRICAL CONTRACTOR SHALL VERIFY CEILING TYPE PRIOR TO ORDERING ANY LIGHT FIXTURES. ELECTRICAL CONTRACTOR SHALL COORDINATE DIMMING DRIVERS/BALLASTS WITH DIMMING SWITCHES/SYSTEMS AND SHALL INCLUDE ALL REQUIRED CONTROL WIRING. LAMPS LED 3500K 5,500 LUMENS LED 3500K 4,400 LUMENS LED 3500K 1,524 LUMENS LED 3000K 1,302 LUMENS LED LED WATTS VOLTS 50 UNV 40 UNV 15 UNV 9.5 UNV 5 UNV 5 UNV DIMMING PROTOCOL 10% 0-10V 10% 0-10V 10% 0-10V N/A N/A N/A N/A N/A N/A DESCRIPTION 2X4 LED FLAT PANEL WITH FROSTED LENS AND WHITE ALUMINUM HOUSING. E = PROVIDE SATCO S8002 10 W EMERGENCY LED DRIVER. 2X2 LED FLAT PANEL WITH FROSTED LENS AND WHITE ALUMINUM HOUSING. RECESSED 6" DIAMETER DOWNLIGHT MOUNTED IN A HARD LID CEILING. 2' LED SQUARE VANITY STRIP LIGHT. WALL MOUNTED EMERGENCY BUG EYE LIGHT FIXTURE WITH ADJUSTABLE HEADS. CEILING MOUNTED, LED ILLUMINATED, 2-HEAD COMBINATION EMERGENCY/EGRESS FIXTURE WITH EMERGENCY BATTERY PACK BACKUP AND REMOTE CAPACITY. NOTES 1 1 1 1 1 1 LIGHTING CONTROLS SCHEDULE TYPE / TAG LINE VOLTAGE MOTION SENSOR SWITCHES LOW VOLTAGE MOTION SENSOR SWITCHES WITH DIMMING LOW VOLTAGE ROOM CONTROLLERS WITH DIMMING LOW VOLTAGE OCCUPANCY SENSORS DAYLIGHTING CONTROLS ACCESSORIES SPECIFIC NOTES: 1. 2. 3. 4. 5. 6. SUBSTITUTION NOTES: THE LIGHTING DESIGN FOR THIS PROJECT IS BASED UPON THE MANUFACTURERS SPECIFIED. IF AN ADDITIONAL SUBSTITUTION IS DESIRED BY THE CONTRACTOR, A SUBSTITUTION REQUEST SUBMITTAL MUST BE PROVIDED AS FOLLOWS: S1. S2. S3. S4. S5. S6. POST BID ALTERNATES: P1. P2. MANUFACTURER WATTSTOPPER WATTSTOPPER WATTSTOPPER WATTSTOPPER WATTSTOPPER WATTSTOPPER WATTSTOPPER LOCATE DEVICE ABOVE ACCESSIBLE CEILING OR WITHIN ELECTRICAL ROOM. LOCATIONS SHOWN ON PLAN ARE SCHEMATIC. PROVIDE 8' OF EXCESS CONTROL WIRING, COILED AND TIED, BETWEEN CEILING MOUNTED SENSORS AND CORRESPONDING ROOM CONTROLLERS. MODIFY LOCATIONS OF CEILING MOUNTED OCCUPANCY SENSORS AS REQUIRED SO THAT SENSORS COMPLY WITH MANUFACTURER'S LIMITATIONS AND PROXIMITY TO HVAC DIFFUSERS. ROOM CONTROLLERS IN OPEN OFFICE TO BE AUTOMATIC ON. ALL OTHERS SHALL BE MANUAL ON. VERIFY COLOR OF DEVICES WITH ARCHITECT PRIOR TO ORDERING MODIFY LOCATIONS OF PHOTOCELL TO COMPLY WITH MANUFACTURER'S RECOMMENDED INSTALLATION LOCATIONS. SUBSTITUTION REQUEST MUST BE RECEIVED BY THE ENGINEER IN WRITING 10 DAYS PRIOR TO BID. FAILURE TO SUBMIT CONSTITUTES A GUARANTEE TO SUPPLY THE SPECIFIED LIGHTING CONTROLS. INFORMATION IS TO BE SUPPLIED COMPARING WIRING REQUIREMENTS, LOAD RATINGS, DIMENSIONS, MATERIAL COMPOSITION, FINISH, VISUAL APPEARANCE AS WELL AS THE "CONTRACTOR NET" PRICING. SAMPLES ARE TO BE PROVIDED UPON REQUEST. IF THE ENGINEER DEEMS THE PROPOSED SUBSTITION ACCEPTABLE, AN ADDENDUM WILL BE ISSUED THAT INCLUDES THE LIGHTING CONTROL DEVICE IN THE SCHEDULE AS AN APPROVED EQUIVALENT. IF THE PROPOSED SUBSTITUTION IS NOT DEEMED ACCEPTABLE, IT WILL NOT BE INLCUDED IN THE ADDENDUM, THUS NOT ACCEPTABLE TO INCLUDE IN THE BID. LIGHTING CONTROLS PRICING SHALL BE COMPLETELY SEPARATE OF ANY LIGHT FIXTURE PRICING. GREAT CARE, TIME AND EXPENSE HAVE BEEN USED TO PROVIDE OUR CLIENT WITH THE LIGHTING AND CONTROLS SYSTEM SPECIFIED. THEREFORE, FOR EACH AND EVERY TYPE OF LIGHT FIXTURE OR CONTROL SYSTEM OFFERED AS AN UNSOLICITED ALTERNATE, A $500.00 FEE WILL BE CHARGED TO THE CONTRACTOR FOR REVIEW OF THE PROPOSED ALTERNATE. THIS CHARGE IS IN NO WAY A GUARANTEE OF APPROVAL, BUT IS SOLELY TO COMPENSATE THE ENGINEER FOR TIME SPENT VALIDATING EQUALITY AND COMPATIBILITY WITH THE PROJECT REQUIREMENTS. THIS REIMBURSEMENT FEE MUST BE RECEIVED BY THE ENGINEER PRIOR TO ANY REVIEW COMMENCING. SAMPLES ARE TO BE PROVIDED UPON REQUEST. MODEL # DSW-301 LMSW-211 LMSW-222 LMRC-211 LMRC-212 LMRC-213 LMDC-100 LMLS-500 LMCT-100-2 VOLTAGE 120/277V LOW VOLTAGE LOW VOLTAGE 120/277V LOW VOLTAGE LOW VOLTAGE LOW VOLTAGE N/A DETECTION TYPE DUAL TECHNOLOGY - - - DUAL TECHNOLOGY PHOTOSENSOR - MOUNTING WALL WALL WALL ABOVE CEILING CEILING CEILING DESCRIPTION LINE VOLTAGE SINGLE ZONE WALL SENSOR SWITCH ON/OFF SINGLE POLE OPERATION LOW VOLTAGE, LOCAL SYSTEM, 1 BUTTON, 1-ROCKER, SINGLE ZONE SWITCH, ON/OFF AND RAISE/LOWER CONTROL. LOW VOLTAGE, LOCAL SYSTEM, 2 BUTTON, 2-ROCKER, 2 ZONE SWITCH, ON/OFF AND RAISE/LOWER CONTROL. ONE, TWO, OR THREE RELAY ROOM CONTROLLER, ON/OFF CONTROL WITH 0-10V DIMMING. PLENUM RATED, INTEGRATES WITH LOW VOLTAGE SENSORS AND SWITCHES LOW VOLTAGE OCCUPANCY SENSOR WITH 1000 SF COVERAGE OPEN LOOP MULTIPLE ZONE DLM PHOTOSENSOR. BATTERY OPERATED CONFIGURATION TOOL WITH IR TRANSCEIVER AND MICRO-USB PORT. NOTES 5 2,5 2,5 1,2,4 3 6 MS DC# DS MS LVD LVD2 PANEL 'H' PANEL 'L' PANEL '2LP1' PANEL '2HML' TO 1ST FLOOR MAIN ELECTRICAL ROOM DISTRIBUTION CORRIDORATI ELECTRICAL CLOSET 2ND FLOOR FOR REFERENCE ONLY ELECTRICAL RISER DIAGRAM NO SCALE A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. P. Q. R. S. T. U. GENERAL NOTES (TYPICAL ALL SHEETS) REFER TO ARCHITECTS REFLECTED CEILING PLANS FOR EXACT PLACEMENT OF LIGHT FIXTURES, SPEAKER AND F.A. DEVICES IN THE CEILING SYSTEM. REFER TO ARCHITECTURAL DETAILS AND ELEVATIONS FOR COORDINATION OF LOCATION OF ALL WIRING DEVICES BEFORE ROUGH-IN OF J-BOXES. INSTALL BLANK COVERPLATE ON ALL OPEN OR ABANDONED DEVICE BOXES. VERIFY COLOR WITH ARCHITECT. WIRING TO BE REMOVED BACK TO THE NEAREST DEVICE TO REMAIN. WIRING SHALL NOT BE TAKEN PAST THE FIRST JUNCTION BOX BEFORE THE PANELBOARD. ANY MATERIAL REMOVED THAT OWNER DOES NOT WISH TO RETAIN SHALL BE REMOVED FROM PROJECT SITE AND DISPOSED OF BY THE CONTRACTOR. NEW CIRCUITRY SHOWN FOR NEW/EXISTING POWER AND LIGHTING IS DIAGRAMMATIC AND IS INTENDED TO SHOW WHICH DEVICES ARE TO BE GROUPED ON INDIVIDUAL CIRCUITS. EXISTING WIRING THAT CONFORMS TO THE INTENT OF THE DRAWINGS MAY BE USED. PROVIDE UPDATED, TYPEWRITTEN PANELBOARD DIRECTORY FOR EACH PANELBOARD WHICH CIRCUITS HAVE BEEN ADDED TO OR MODIFIED. CONTRACTOR TO REFERENCE BRANCH CIRCUIT COPPER CONDUCTOR AND CONDUIT SIZING CHART FOR SIZING OF BRANCH CIRCUITS AND OR FEEDERS AT OR BELOW 100AMPS. EXISTING RECEPTACLES AND SWITCHES TO REMAIN EXCEPT THOSE THAT ARE CHIPPED, BROKEN OR DAMAGED IN ANY OTHER WAY SHALL BE REPLACED TO MATCH EXISTING. SUPPORT ALL LIGHT FIXTURES WITH A MINIMUM OF (4) 12 GA. HANGER WIRES TO STRUCTURE ABOVE. CONNECT EXIT AND EMERGENCY LIGHTS TO HOT LEG, NOT SWITCH LEG. REPAIR AND/OR REPLACE ANY DAMAGED CEILING TILE OR GRID DUE TO INSTALLATION OF CONDUITS, ETC. ABOVE EXISTING CEILING. WALK BUILDING WITH ARCHITECT PRIOR TO COMMENCING WORK TO NOTE ANY EXISTING DAMAGED CEILING TILE OR GRID. CLEAN AND CHECK ALL EXISTING LIGHT FIXTURES FOR PROPER OPERATION AND REPLACE ANY BROKEN SOCKETS, LENS, LOUVERS, OR DEFECTIVE BALLAST. RELAMP ALL EXISTING FIXTURES WITH NEW LAMPS. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN BID ALL COSTS ASSOCIATED WITH FIRE ALARM MODIFICATIONS. THIS WORK SHALL INCLUDE POWER EXTENDER PANEL, SMOKE DETECTORS, HORN/STROBES, PULL STATIONS, REMOTE INDICATING LIGHTS AND ANY OTHER FIRE ALARM WORK SHOWN ON PLANS. ALL WIRING, PLENUM RATED CABLING, BETWEEN DEVICES SHALL BE INCLUDED IN WORK TO PROVIDE AN OPERATIONAL EXTENSION OF THE EXISTING FIRE ALARM SYSTEM. ALIGN ALL WIRING DEVICES IN VERTICAL ALIGNMENT. IF ANY DEVICE(S) ARE FOUND NOT TO BE INSTALLED PER DETAIL CONTRACTOR SHALL RELOCATE AND PAY ALL ASSOCIATED COSTS ASSOCIATED WITH THE RELOCATION(S). LIGHTING INDICATED ABOVE EXIT DISCHARGE DOOR IS FOR MEANS OF EGRESS ILLUMINATION PER IBC 1006.1. MEANS OF EGRESS TO BE ILLUMINATED AT NOT LESS THAN 1 FOOTCANDLE AT THE FLOOR. CONTRACTOR SHALL PROVIDE AND INSTALL IF NECESSARY ADDITIONAL EMERGENCY FIXTURES IF NECESSARY TO MEET THE REQUIRED READINGS. CONDUIT SHALL BE USED FOR CONDUCTORS WHERE REQUIRED BY N.E.C. INSTALL FIRE ALARM DEVICES THAT COMPLY WITH APPLICABLE CODES. INCLUDING BUT NOT LIMITED TO THE NFPA, UL, ADA, IBC OR ANY OTHER AUTHORITIES HAVING JURISDICTION. FIRE ALARM CONTRACTOR IS RESPONSIBLE OF TESTING AND VERIFYING THAT THE AUDIBILITY OF THE FIRE ALARM SYSTEM MEETS A MINIMUM OF 15 DBA ABOVE AMBIENT NOISE LEVELS. AFTER INSTALLATION AND BEFORE CERTIFICATE OF OCCUPANCY. ADD HORNS WHERE REQUIRED TO MAINTAIN MINIMUM LEVELS. CONTRACTOR SHALL PROVIDE HIS/HER OWN SUPPORTING OF CABLING FROM STRUCTURE ABOVE, I.E. TEMPERATURE CONTROL WIRING, SECURITY CONTROL WIRING, FIRE ALARM CONTROL WIRING, OR ANY OTHER WIRING CONTAINING VOLTAGE. CONTRACTOR SHALL NOT RUN PARALLEL WITH OR BE SUPPORTED BY ANY UTP, COAX OR VIDEO CABLING (CABLES INDICATED ON TECHNOLOGY DRAWINGS). IF CABLES ARE FOUND TO BE SUPPORTED WITH THESE CABLES, CONTRACTOR SHALL REMOVE CABLES, REROUTE AND RE-SUPPORT AT THEIR OWN EXPENSE. IF UTP CABLES ARE DAMAGED WHILE EITHER INSTALLING OR REMOVING SUCH CABLES, THE CONTRACTOR(S) THAT DID SUCH DAMAGE SHALL COVER COST TO REPLACE CABLES AT THEIR OWN EXPENSE. FIRE STOPPING REQUIREMENTS CONTRACTOR TO PROVIDE FIRESTOPPING AT ALL FIRE RATED ASSEMBLIES MEETING THE MANUFACTUER'S FIRESTOPPING U.L. LISTED DETAILS AND INSTRUCTIONS PER LOCAL CODES AND JURISDICTIONS. CONTRACTOR IS RESPONSIBLE FOR COORDINATING LOCATIONS WITH ARCHITECTURAL FIRE RATINGS ON PLANS OR AS REQUIRED. ELECTRICAL SYMBOLS FLUSH MOUNTED EQUIPMENT, TYPE AS INDICATED ON PLANS SURFACE MOUNTED EQUIPMENT, TYPE AS INDICATED ON PLANS 480/277V PANELBOARD (FLUSH), TOP MOUNTED 6'-0" AFF 208Y/120V OR 120/240V PANELBOARD (FLUSH), TOP MOUNTED 6'-0" AFF 208Y/120V OR 120/240V PANELBOARD (SURFACE), TOP MOUNTED 6'-0" AFF 480/277V PANELBOARD (SURFACE), TOP MOUNTED 6'-0" AFF WALL MOUNTED LIGHT FIXTURE, SIZE AND TYPE AS NOTED WALL WASH OR RECESSED CEILING LIGHT FIXTURE COMBINATION EXIT SIGN/EMERGENCY LIGHTING UNIT, CEILING OR WALL MOUNTED, SHADED SIDE(S) INDICATES FACE SIDE(S) OF EXIT EXIT SIGN, DOUBLE FACED, ARROWS AS SHOW ON DRAWING, SHADED SIDE(S) INDICATES FACE SIDE(S) OF EXIT EXIT SIGN, SINGLE FACED, ARROWS AS SHOW ON PLANS, SHADED SIDE(S) INDICATES FACE SIDE(S) OF EXIT GROUNDING CONDUCTOR, MINIMUM NO. 12 WIRE EXCEPT AS NOTED CONDUIT RUN UNDERGROUND OR CONCEALED IN FLOOR SLAB LED STRIP FIXTURE LED LIGHT FIXTURE ON EMERGENCY POWER OR WITH INTEGRAL EMERGENCY BALLAST; REFER TO FIXTURE SCHEDULE FOR TYPE LED LIGHT FIXTURE; LETTER DENOTES FIXTURE TYPE HOMERUN INDICATED LIKE THIS INDICATES THREE SEPARATE CIRCUITS INDICATES X,X= 2-POLE C.B. OR X,X,X= 3-POLE C.B. PANEL - BREAKER NUMBER (IDENTIFICATION) BRANCH CIRCUIT CONCEALED IN CEILING OR WALL, ARROWS INDICATED HOMERUNS TO PANEL, ALL CONDUCTORS ARE NOTED IN PANEL SCHEDULE PHASE CONDUCTORS NEUTRAL CONDUCTORS GROUND CONDUCTORS LP1-10 1,3 OR 1,3,5 OR OR CONDUIT CONCEALED IN CEILING OR WALL WITH THREE CONDUCTORS: 1-PHASE, 1-NEUTRAL, 1-GROUND WIRE, MINIMUM NO.12 WIRE UNLESS OTHERWISE SPECIFIED ON PLANS A A AE M AE M OR 5 3 1 CEILING OR WALL MOUNTED EMERGENCY LIGHTING UNIT WITH INTEGRAL BATTERY AND UNIT MOUNTED HEADS OR DUPLEX RECEPTACLE W/GROUND FAULT PROTECTION,+ 1'-6" AFF OR AS NOTED DOUBLE DUPLEX RECEPTACLE, +1'-6" AFF OR AS NOTED HEAVY DUTY RECEPTACLE; VOLTAGE, PHASE AND AMPS AS NOTED, +1'-6" OR AS NOTED DUPLEX RECEPTACLE, +1'-6" AFF OR AS NOTED SWITCH DESIGNATIONa,b,c,d MOTION SENSOR SWITCH, +3'-10" AFF TO CENTERLINE OF DEVICE BOXMS INDICATES RECEPTACLE ABOVE COUTERTOP. RE: PLANS THREE-WAY SWITCH, +3'-10" AFF TO CENTERLINE OF DEVICE BOX SINGLE POLE SWITCH, +3'-10" AFF TO CENTERLINE OF DEVICE BOX 3 ROUND POKE-THRU WITH TYPE INDICATED, SEE SPECS. POWER POLE WALL OR CEILING MOUNTED JUNCTION BOX WALL MOUNTED JUNCTION BOX WITH BLANK COVERPLATE CATV JUNCTION BOX WITH 3/4" CONDUIT STUBBED UP OUT OF BOX TO ABOVE ACCESSIBLE CEILING, +1'-6" AFF OR AS NOTEDTV JJOR B DATA/VOICE OUTLET WITH 3/4" CONDUIT STUBBED UP OUT OF BOX TO ABOVE ACCESSIBLE CEILING, +1'-6" AFF OR AS NOTED DATA/VOICE OUTLET WITH 3/4" CONDUIT STUBBED UP OUT OF BOX TO ABOVE ACCESSIBLE CEILING, INSTALLED ABOVE COUNTERTOP FIRE ALARM STROBE LIGHT, +6'-8" AFF FIRE ALARM STROBE LIGHT, CEILING MOUNTED FIRE ALARM COMBINATION AUDIBLE/VISUAL WALL MOUNTED, +6'-8" AFF FIRE ALARM COMBINATION AUDIBLE/VISUAL CEILING MOUNTED (FLUSH) INDICATES WIRING DEVICE ABOVE, RE: DRAWING MECHANICAL EQUIPMENT CALL OUT HEIGHT TO CENTERLINE OF OUTLET BOX ABOVE FINISHED FLOOR AFF ETR FA +3'-10" ABOVE FINISHED FLOOR EXISTING TO REMAIN FIRE ALARM AHU-1 SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 RPH ELECTRICAL SCHEDULES, GEN. NOTES, & SYMBOLS E301 1 JMP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 PERMIT SET 08/06/25 08.06 .2025 (E) TOILET 122 HOSPITALITY 123 TOILET 124 (E) TREATMENT 125 (E) TREATMENT 126 OPEN GYM 127 (E) OPEN TREATMENT 128 (E) LAUNDRY/BREAK ROOM 129 (E) MECH 130 RECEPTION 121 (E) WAITING 120 FP01 FP01 FP01 FP01 FP01 FIRE PROTECTION DESIGN CRITERIA FIRE PROTECTION LEGEND RECONFIGURE EXISTING BASE BUILDING FIRE SPRINKLER LAYOUT WITHIN THIS AREA IN ORDER TO PROVIDE PROPER COVERAGE PER NFPA 13 AND LOCAL AUTHORITIES. ALL REMOVED / RELOCATED FIRE SPRINKLERS MUST BE REPLACED WITH NEW PER NFPA 13. NEW SPRINKLERS TO MATCH EXISTING. REFER TO REFLECTED CEILING PLANS FOR COORDINATION WITH LIGHTS, DIFFUSERS, EXIT SIGNS, ETC. LIGHT HAZARD - PROVIDE PROPER COVERAGE PER NFPA 13 (0.1 GPM PER 1500 SF) PLUS 100 GPM HOSE STREAM ALLOWANCE. ORDINARY HAZARD GROUP 1 - PROVIDE PROPER COVERAGE PER NFPA 13 (0.15 GPM PER 1500 SF) PLUS 250 GPM HOSE STREAM ALLOWANCE. A. B. C. D. E. F. G. H. I. J. K. L. M. N. ENTIRE BUILDING AS SHOWN ON DRAWINGS IS CURRENTLY PROVIDED WITH A WET TYPE SPRINKLER SYSTEM. MODIFY SYSTEM AS NECESSARY FOR NEW WALL LAYOUTS AND IN COMPLIANCE WITH THE RULES AND REGULATIONS OF APPLICABLE FEDERAL, STATE AND LOCAL LAWS, CODES AND ORDINANCES, THE OWNER'S INSURANCE COMPANY AND NFPA 13. FURNISH ALL MATERIALS, LABOR, TOOLS, TRANSPORTATION, INCIDENTALS AND APPURTENANCES TO COMPLETE IN EVERY DETAIL AND LEAVE IN WORKING ORDER ALL ITEMS OF WORK REQUIRED FOR STRICT COMPLIANCE. NEW FIRE PROTECTION PIPING AND FITTINGS SHALL MATCH EXISTING, OR PROVIDE SCHEDULE 40 FOR 2" AND SMALLER WITH THREADED ENDS AND SCHEDULE 10 FOR 1-1/2" AND LARGER WITH ROLL-GROOVED ENDS AND GROOVED JOINTS. ALL PIPING IN AREAS WITH CEILINGS SHALL BE RUN CONCEALED WITH NO EXCEPTIONS UNLESS COORDINATED WITH ARCHITECT AND ENGINEER. PIPE SIZES SHOWN ON PLANS FOR INFORMATION ONLY. VERIFY BY HYDRAULIC CALCULATIONS. NEW FIRE SPRINKLERS SHALL MATCH EXISTING IN TYPE, STYLE AND APPEARANCE. ANY REMOVED/RELOCATED FIRE SPRINKLERS MUST BE REPLACED WITH NEW PER NFPA 13. CONTRACTOR RESPONSIBLE FOR FIELD VERIFICATION OF ALL INFORMATION. ALL SPRINKLERS IN LAY-IN CEILINGS ARE TO BE CENTERED ±1/2" IN 2'x2' PORTION OF TILE. ALL SPRINKLERS IN GYP-BOARD CEILINGS ARE TO BE CENTERED ±1/2" WITH LIGHT FIXTURES AND ALIGNED WITH ALL OTHER DEVICES IN CEILING IN BOTH DIRECTIONS. COORDINATE WITH ARCHITECT. FIRE PROTECTION CONTRACTOR SHALL PREPARE DETAILED AND COORDINATED SHOP DRAWINGS SO AS TO AVOID CONFLICTS IN THE FIELD. CONTRACTOR SHALL COORDINATE WITH REFLECTED CEILING PLAN, DUCTWORK LAYOUT AND LIGHTING LAYOUT. ALL COORDINATION SHALL TAKE PLACE PRIOR TO INSTALLATION. CONTRACTOR SHALL FILE ALL DRAWINGS, PAY ALL FEES AND OBTAIN PERMITS AND CERTIFICATES OF INSPECTIONS RELATIVE TO THIS WORK. CONTRACTOR SHALL OBTAIN CURRENT FIRE HYDRANT FLOW TEST DATA AND USE FOR SYSTEM HYDRAULIC CALCULATIONS. USE DATA TO DESIGN SYSTEMS ACCORDINGLY BASED ON AVERAGE NUMBERS PLUS 10% SAFETY. PREPARE AND SUBMIT SHOP DRAWINGS, PRODUCT DATA AND HYDRAULIC CALCULATIONS AS REQUIRED. ALL INFORMATION SHOWN ON FIRE PROTECTION DRAWINGS SHALL BE INCLUDED ON THE SHOP DRAWINGS. CONTRACTOR TO BE RESPONSIBLE FOR MAKING FINAL COORDINATION WITH STRUCTURE AND ALL OTHER TRADES PRIOR TO SUBMITTING SHOP DRAWINGS. ALL ELEVATIONS OF PIPE MUST BE SHOWN ON SHOP DRAWINGS. SPRINKLER SYSTEM SHALL BE TESTED AND DRAINED PER NFPA STANDARDS AND LOCAL AND STATE AUTHORITY HAVING JURISDICTION.COMPLETED CONTRACTOR MATERIAL TEST CERTIFICATES SHALL BE FORWARDED TO OWNER. FIRE SPRINKLER CONTRACTOR IS RESPONSIBLE FOR COORDINATION WITH FIRE ALARM PANEL AND SUPERVISION OF NEW SPRINKLER TAMPER AND FLOW SWITCHES. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. SPRINKLER HEAD PLACEMENT SHALL BE OUT OF THE SWING AREA OF DOORS TO AVOID CONFLICT WITH TALL DOORS. SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 IOH FLOOR PLAN -FIRE PROTECTION FP100 1 JMP SCALE:1/4" = 1'-0" FLOOR PLAN - FIRE PROTECTION FLOOR PLAN NOTESFP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 FP01 EXISTING FIRE SPRINKLER COVERAGE TO REMAIN.NPERMIT SET 08/06/25 08.06 .2025 T T T T T 34 x 2 6 16ø 8ø 8ø 10 ø 8ø 14 ø 8ø 10ø 10ø 10ø 10ø 16 ø 10ø 10ø 10ø 10ø 16 ø 12 ø 8ø 8ø 8ø 8ø 8ø 8ø 10ø 16 ø 10ø 34x26 10 ø 10 ø 20x10 DM01 DM02 DM03 DM04 DM05 DM05 DM05 DM05 DM03DM03 DM03 DM03 DM03 DM03 DM03 DM03 DM03 DM03 DM03 DM03 DM03 DM03DM03 DM03 DM03 DM03 DM03 DM03 DM06 DM04 DM04 SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 IOH FLOOR PLAN - MECHANICAL DEMOLITION DM100 1 JMP FLOOR PLAN NOTESDM 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 SCALE:1/4" = 1'-0" FLOOR PLAN - MECHANICAL DEMOLITIONNDM01 DISCONNECT AND REMOVE EXISTING CEILING MOUNTED EXHAUST FAN. CLEAN AND RETAIN FOR RE-INSTALLATION DURING NEW WORK. RE: NEW WORK PLAN. DM02 REMOVE EXISTING THERMOSTAT AND ASSOCIATED CONTROL WIRING BACK TO TERMINAL UNIT. CLEAN AND RETAIN FOR RE-INSTALLATION DURING NEW WORK. RE: NEW WORK PLAN. DM03 DISCONNECT AND REMOVE EXISTING SUPPLY DIFFUSER AND FLEX DUCT. CONTRACTOR SHALL MEASURE AND NOTE NECK SIZE AND AIRFLOW OF DIFFUSER PRIOR TO REMOVAL. DM04 REMOVE EXISTING RETURN GRILLE ALONG WITH ASSOCIATED RETURN AIR BOOT. DM05 EXISTING THERMOSTAT TO REMAIN. DM06 EXISTING EXHAUST FAN TO REMAIN. PERMIT SET 08/06/25 08.06 .2025 T T T T T M01 M03 HOSPITALITY 123 OPEN GYM 127 (E) OPEN TREATMENT 128 (E) TREATMENT 126 (E) TREATMENT 125 TOILET 124 (E) TOILET 122 (E) WAITING 120 RECEPTION 121 (E) MECH 130 (E) LAUNDRY/BREAK ROOM 129 34x26 12ø 16ø 34 x 2 6 11 x 1 1 20x10 12 ø 12 ø 16 ø 16 ø 14 ø 1 0 ø 10 ø 8ø 10ø 16 ø 1 0 ø (TYP)M02 - SA1 (TYP) - RA1 - RA2 8ø 12 ø 8ø 8ø 10 ø 10ø 10ø 10ø 10ø 10ø 10ø 8ø 8ø 8ø 8ø SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 IOH FLOOR PLAN - MECHANICAL M100 1 JMP SCALE:1/4" = 1'-0" FLOOR PLAN - MECHANICAL FLOOR PLAN NOTESM 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 M01 REINSTALL EXISTING EXHAUST FAN AT LOCATION INDICATED. ROUTE NEW 6" ROUND EXHAUST AIR DUCT AND RECONNECT TO EXISTING EXHAUST AIR DUCT UP THROUGH ROOF ABOVE REMOVED RESTROOM. FAN SHALL BE CONTROLLED WITH THE LIGHT SWITCH IN ASSOCIATED ROOM. M02 INSTALL NEW SUPPLY DIFFUSER AT LOCATION INDICATED. NECK SIZE AND AIRFLOW SHALL MATCH MEASUREMENTS TAKEN OF REMOVED DIFFUSER. M03 REINSTALL EXISTING THERMOSTAT AT LOCATION INDICATED. EXTEND, MODIFY AND SUPPLY NEW WIRING AS REQUIRED TO RECONNECT THERMOSTAT AT NEW LOCATION.NPERMIT SET 08/06/25 08.06 .2025 GRILLE, REGISTER AND DIFFUSER SCHEDULE MARK MANUFACTURER MODEL FACE TYPE FRAME TYPE* FACE NECK SIZE SIZE COLOR NOTES (IN.) (IN.) SA1 PRICE SPD SQUARE PLAQUE LAY-IN 24x24 SEE PLANS WHITE 1 RA1 PRICE PDDR PERFORATED LAY-IN 24x12 - WHITE - RA2 PRICE PDDR PERFORATED LAY-IN 24x24 - WHITE - NOTES: 1. 4-WAY THROW PATTERN UNLESS OTHERWISE SHOWN ON THE DRAWINGS. *CONTRACTOR SHALL VERIFY CEILING TYPE PRIOR TO ORDERING DIFFUSERS. A. B. C. D. E. F. G. H. I. J. K. L. M. N. O. GENERAL NOTES (TYPICAL ALL SHEETS) MECHANICAL CONTRACTOR IS RESPONSIBLE TO SEE THAT WORK MEETS AND IS IN ACCORDANCE WITH ALL REQUIREMENTS OF FEDERAL, STATE, AND LOCAL LAWS AND CODES AND/OR REQUIREMENTS, INCLUDING HEALTH CODES AND BUILDING OWNER. ALL EXISTING DUCTWORK SHOWN ON DRAWINGS IS SCHEMATIC AND IS BASED ON EXISTING RECORD DRAWINGS PROVIDED BY THE OWNER AND DO NOT REFLECT EXACT EXISTING CONDITIONS. CONTRACTOR TO FIELD VERIFY EXACT DEPTH AND/OR LOCATIONS ON JOB SITE. CONTRACTOR SHALL REROUTE NEW WORK TO ACCOMMODATE EXACT LOCATIONS OF EXISTING UTILITIES, STUBOUTS AND/OR CONNECTIONS. CUTTING AND PATCHING OF FLOORS, WALLS, CEILING, ETC., REQUIRED IN STRICT ACCORDANCE WITH THE RULES AND REGULATIONS OF THE ARCHITECT'S AND/OR BUILDING OWNER REQUIREMENTS. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION TO AVOID ROUTING CONFLICTS. ANY MATERIAL REMOVED THAT OWNER DOES NOT WISH TO RETAIN SHALL BE REMOVED FROM PROJECT SITE AND DISPOSED OF BY CONTRACTOR. ALL REMOVED DEVICES THAT ARE BEING REUSED FOR NEW CONSTRUCTION SHALL BE CLEANED OF ALL DIRT AND STORED ON SITE. ALL THERMOSTATS SHALL BE MOUNTED TO MATCH BUILDING STANDARDS UNLESS OTHERWISE NOTED. MECHANICAL CONTRACTOR SHALL PROVIDE NEW 1" FARR TYPE PLEATED FILTERS ON ALL TERMINAL BOXES WHICH ARE IN PROJECT SCOPE OF WORK PRIOR TO BALANCING. PROVIDE TEMPORARY FILTERS ON RETURN AIR OPENINGS DURING CONSTRUCTION. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING AND RETAINING ALL TEMPERATURE CONTROLS FROM EXISTING FAN POWERED BOXES AND VAV BOXES FOR REINSTALLATION UNDER NEW WORK. UPON REINSTALLATION, CONTRACTOR SHALL VERIFY PROPER OPERATION AND NOTIFY THE OWNER'S REPRESENTATIVE IN WRITING IF PROBLEMS ARE FOUND. ALL DUCTWORK, DIFFUSERS, TERMINAL UNITS, ETC. ARE EXISTING TO REMAIN, UNLESS NOTED OTHERWISE. MECHANICAL CONTRACTOR SHALL BID WORK IN CEILING SPACE BELOW TO BE COMPLETED AFTER HOURS ONLY IN AREAS THAT ARE NOT OCCUPIED BY THE OWNER'S PERSONNEL. CONTRACTOR SHALL COORDINATE WORK/TIMES WITH THE OWNER'S REPRESENTATIVE. INSTALL ELASTOMERIC JOINT SEALER AROUND ALL DUCTS, PIPES, ETC. PASSING THRU INTERIOR NON-RATED CONCRETE AND MASONRY WALLS, GYPSUM-BOARD PARTITIONS, AND CONCRETE FLOOR/ROOF SLABS. FOR FIRE RATED INTERIOR CONCRETE AND MASONRY WALLS, GYPSUM- BOARD PARTITIONS, AND CONCRETE FLOOR/ROOF SLABS SEAL ALL DUCTS, PIPES, ETC. INSTALL FIRESTOP MATERIALS IN ALL GAPS PRIOR TO SEALANT APPLICATION. INSTALL SEALER ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. MECHANICAL CONTRACTOR SHALL COORDINATE ALL TEMPERATURE CONTROL WORK WITH BUILDING OWNER. BUILDING SYSTEM SHALL REMAIN OPERATIONAL AT ALL TIMES. UPON REQUEST FOR ELECTRONIC FILES, CONTRACTOR SHALL FILL OUT, SIGN AND RETURN ELECTRONIC MEDIA RELEASE FORM FROM ENGINEER AND PROVIDE PAYMENT FOR FEES STIPULATED ON ELECTRONIC MEDIA RELEASE FORM. UPON RECEIPT OF COMPLETED RELEASE FORM AND PAYMENT, ELECTRONIC FILES WILL BE RELEASED. ALL CABLE TIES FOR LOW VOLTAGE SYSTEMS LOCATED IN PLENUMS UTILIZED FOR AIR MOVEMENT THAT ARE NOT INSTALLED IN CONDUIT SHALL BE 25/50 FLAME AND SMOKE RATED, HELLERMANN TYTON T50R2C2UL OR EQUIVALENT. MECHANICAL SYMBOLS SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE MANUAL VOLUME DAMPER EXHAUST DUCT UP EXHAUST DUCT DOWN RETURN DUCT UP RETURN DUCT DOWN SUPPLY DUCT UP SUPPLY DUCT DOWN EXHAUST DUCT RETURN DUCT SUPPLY DUCT CONNECT TO EXISTING NEW DUCTWORK EXISTING DUCT TO REMAIN EXISTING DUCTWORK TO BE REMOVED THERMOSTAT RISE OR DROP IN DUCTDR/D T FLEX DUCT MAIN DUCT ROUND FLEX DUCT - 60" MAX. LENGTH FLEX DUCT TAKE-OFF WITH MANUAL DAMPER; SEE DUCT STANDARD DETAIL MAIN DUCT INSULATED SHEET METAL ELBOW OR THERMAFLEX "FLEX FLOW ELBOW" NOTE: 1. BRANCH DUCT RUNOUT TO DIFFUSER SHALL BE THE SAME SIZE AS THE DIFFUSER NECK UNLESS OTHERWISE INDICATED ON PLAN. 2. IN LOCATIONS WHERE TAKEOFFS ARE INSTALLED ABOVE HARD OR NON- ACCESSIBLE CEILINGS CONTRACTOR TO PROVIDE SCREWS TO PREVENT BRANCH DUCT FROM SLIDING OFF FITTING. INSPECT PRIOR TO CEILING INSTALLATION. BAND FLEX ENDS WITH NYLON STRAPS (TYP) MANUAL DAMPER @ DIFFUSER ONLY WHERE DUCT-MOUNTED DAMPER WOULD BE INACCESSIBLE DIFFUSER - SCREWED INTO CEILING T-BAR AND/OR SUPPORTED DIRECTLY FROM STRUCTURE PER SEISMIC CODE REQUIREMENTS SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 IOH MECHANICAL SCHEDULES, GEN. NOTES, & SYMBOLS M200 1 JMP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 NOT TO SCALE DIFFUSER DETAIL PERMIT SET 08/06/25 08.06 .2025 SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 IOH/RPH SPECIFICATIONS MEP100 1 JMP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 PERMIT SET 08/06/25 08.06 .2025 SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 IOH/RPH SPECIFICATIONS MEP101 1 JMP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 PERMIT SET 08/06/25 08.06 .2025 DP01 DP01 V CW HW DP02 HW CW V SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 IOH FLOOR PLAN -PLUMBING DEMOLITION DP100 1 JMP SCALE:1/4" = 1'-0" FLOOR PLAN - PLUMBING DEMOLITION FLOOR PLAN NOTESDP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 DP01 DISCONNECT AND REMOVE EXISTING PLUMBING FIXTURE ALONG WITH ASSOCIATED WATER AND VENT PIPING BACK TO BEHIND WALL AND CAP. REMOVE WASTE PIPING TO BELOW FLOOR AND CAP. DP02 DISCONNECT AND REMOVE EXISTING PLUMBING FIXTURE ALONG WITH ASSOCIATED WATER AND VENT PIPING BACK TO MAIN AND CAP. REMOVE WASTE PIPING TO BELOW FLOOR AND CAP.NPERMIT SET 08/06/25 08.06 .2025 WC-1L-1 S-1 4" W1 1/2" W4" W 1/2" CW 1/ 2 " H W 3/4" CW 2" V1 1/2" V 1/2" HW P01 HOSPITALITY 123 (E) TOILET 122 TOILET 124 (E) TREATMENT 125 (E) TREATMENT 126 OPEN GYM 127 (E) OPEN TREATMENT 128 (E) LAUNDRY/BREAK ROOM 129 (E) MECH 130 (E) WAITING 120 RECEPTION 121 WCO P02 SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 IOH FLOOR PLAN -PLUMBING P100 1 JMP SCALE:1/4" = 1'-0" FLOOR PLAN - PLUMBING FLOOR PLAN NOTESP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 P01 CONNECT NEW 4" WASTE PIPING INTO EXISTING WASTE PIPING OF EQUAL OR GREATER SIZE SERVING THE EXISTING RESTROOM. P02 INSTALL NEW SINK AT LOCATION INDICATED AND CONNECT NEW 1/2" CW, 1/2" HW, 1-1/2" V, AND 1-1/2" W. EXTEND AND/OR RECONFIGURE EXISTING WATER, WASTE, AND VENT PIPING SERVING EXISTING LAVATORY TO ACCOMMODATE NEW FIXTURE AS REQUIRED.NPERMIT SET 08/06/25 08.06 .2025 PLUMBING FIXTURE SCHEDULE MARK NO. FIXTURE TYPE MANUFACTURER MODEL NO. DESCRIPTION MINIMUM CONNECTION SIZE CW HW WASTE VENT WC-1 WATER CLOSET (ACCESSIBLE) MANSFIELD 384-387 "SUMMIT" FLOOR MOUNTED FLUSH TANK, WHITE VITREOUS CHINA, HIGH EFFICIENCY (1.28 GPF), ELONGATED POWER WASH BOWL, FULLY GLAZED 2" TRAP WAY, CLOSE-COUPLED TANK, 16-1/2" RIM HEIGHT. 1/2"- 4" 2" ACCESSORIES: BEMIS 2155SSC WHITE OPEN FRONT SEAT LESS COVER WITH SELF SUSTAINING CHECK HINGES, BOLTS AND CAPS, LOOSE KEY ANGLE STOP AND CHROME-PLATED RISER. NOTE: HANDLE TO BE ON WIDE SIDE OF FIXTURE. L-1 LAVATORY MANSFIELD 2018HBNS-4 WALL HUNG, VITREOUS CHINA, 22" X 18-1/8", FRONT OVERFLOW, INTEGRAL BACK.1/2" 1/2" 1-1/2" 1-1/2" (ACCESSIBLE) "GRANDE ISLE" SYMMONS MODEL S-20-0.5 "SYMMETRIX" DECK MOUNTED, THREE HOLE CERAMIC DISC MIXING FAUCET WITH 4-7/16” SPOUT WITH SINGLE LEVER HANDLE WITH RED AND BLUE INDICATOR ON HANDLE, 0.5 GPM MAXIMUM FLOW RATE. ACCESSORIES: PROVIDE LEONARD 170-LF LEAD FREE BRONZE THERMOSTATIC MIXING VALVE WITH 0.25 GPM MINIMUM FLOW RATE, INTEGRAL CHECK VALVES, DISCHARGE SET AT 105°F, MOUNTED DOWNSTREAM OF FIXTURE STOPS, WITH HOT AND COLD WATER PIPED TO VALVE, TEMPERED AND COLD WATER TO LAVATORY. CHICAGO FAUCETS MODEL 337-XCP OFFSET GRID DRAIN 1-1/4" X 1-1/2" 17 GA. SEMI-CAST BRASS P-TRAP WITH CLEANOUT AND CHROME-PLATED RISERS WITH LOOSE KEY ANGLE STOPS. PROVIDE WITH FULLY MOLDED FLEXIBLE VINYL INSULATION KIT TO COVER TRAP, SUPPLIES AND STOPS, TRUBRO E-Z LAV GUARD. NOTE: MOUNT FIXTURE RIM 34” ABOVE FLOOR. S-1 SINK ELKAY GE12521 SINGLE COMPARTMENT SELF RIMMING SINK, 22 GA, TYPE 300 STAINLESS STEEL, 5-3/8” DEEP BOWL. 1/2" 1/2"2"1-1/2" (ACCESSIBLE) SYMMONS MODEL S-23 "SYMMETRIC" DECK MOUNTED FAUCET WITH CERAMIC OPERATING CARTRIDGE, 8-3/4" SWING SPOUT WITH 1.5 GPM AERATOR, 8" CENTERS, 3 HOLE MOUNTING, POLISHED CHROME FINISH. ACCESSORIES: ELKAY LKAD-35 STRAINER WITH OFFSET 1-1/2" TAILPIECE, 1-1/2" 17 GA. SEMI-CAST BRASS P-TRAP WITH CLEANOUT, CHROME-PLATED RISERS WITH LOOSE KEY ANGLE STOPS. A. B. C. D. E. F. G. H. I. J. K. L. M. GENERAL NOTES (TYPICAL ALL SHEETS) PLUMBING CONTRACTOR IS RESPONSIBLE TO SEE THAT WORK MEETS AND IS IN ACCORDANCE WITH ALL REQUIREMENTS OF FEDERAL, STATE, AND LOCAL LAWS AND CODES AND/OR REQUIREMENTS, INCLUDING HEALTH CODES AND BUILDING OWNER. ALL EXISTING PIPING SHOWN ON DRAWINGS IS SCHEMATIC AND IS BASED ON EXISTING RECORD DRAWINGS PROVIDED BY THE OWNER AND DO NOT REFLECT EXACT EXISTING CONDITIONS. CONTRACTOR TO FIELD VERIFY EXACT DEPTH AND/OR LOCATIONS ON JOB SITE. CONTRACTOR SHALL REROUTE NEW WORK TO ACCOMMODATE EXACT LOCATIONS OF EXISTING UTILITIES, STUBOUTS AND/OR CONNECTIONS. CUTTING AND PATCHING OF FLOORS, WALLS, CEILING, ETC., REQUIRED IN STRICT ACCORDANCE WITH THE RULES AND REGULATIONS OF THE ARCHITECT'S AND/OR BUILDING OWNER REQUIREMENTS. COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO INSTALLATION TO AVOID ROUTING CONFLICTS. ANY MATERIAL REMOVED THAT OWNER DOES NOT WISH TO RETAIN SHALL BE REMOVED FROM PROJECT SITE AND DISPOSED OF BY CONTRACTOR. PLUMBING CONTRACTOR SHALL BID WORK IN CEILING SPACE BELOW TO BE COMPLETED AFTER HOURS ONLY IN AREAS THAT ARE NOT OCCUPIED BY THE OWNER'S PERSONNEL. CONTRACTOR SHALL COORDINATE WORK/TIMES WITH THE OWNER'S REPRESENTATIVE. INSTALL ELASTOMERIC JOINT SEALER AROUND ALL PIPES PASSING THRU INTERIOR NON- RATED CONCRETE AND MASONRY WALLS, GYPSUM-BOARD PARTITIONS, AND CONCRETE FLOOR/ROOF SLABS. FOR FIRE RATED INTERIOR CONCRETE AND MASONRY WALLS, GYPSUM-BOARD PARTITIONS, AND CONCRETE FLOOR/ROOF SLABS SEAL ALL PIPES. INSTALL FIRESTOP MATERIALS IN ALL GAPS PRIOR TO SEALANT APPLICATION. INSTALL SEALER ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. PLUMBING CONTRACTOR SHALL MAKE FINAL CONNECTION TO ALL EQUIPMENT BY OTHERS. VERIFY CONNECTIONS SIZES AND REQUIREMENTS. PIPING ROUTED BELOW COUNTER IN CABINETS SHALL BE ROUTED AS NOTED. NOT TO INTERFERE WITH DRAWERS, SHELVES, EQUIPMENT, ETC., AND SUPPORT FROM BACK WALL OF CABINET. PLUMBING CONTRACTOR SHALL BID AND SCHEDULE ALL CORE DRILLING AND HAMMER DRILLING FOR AFTER BUSINESS HOURS. PLUMBING CONTRACTOR SHALL SCAN FLOOR UTILIZING GROUND PENETRATING RADAR PRIOR TO ANY CORE DRILLING OR SAW CUTTING OF SLAB AND SHALL VERIFY PLACEMENT WITH BUILDING OWNER'S REPRESENTATIVE PRIOR TO DRILLING. UPON REQUEST FOR ELECTRONIC FILES, CONTRACTOR SHALL FILL OUT, SIGN AND RETURN ELECTRONIC MEDIA RELEASE FORM FROM ENGINEER AND PROVIDE PAYMENT FOR FEES STIPULATED ON ELECTRONIC MEDIA RELEASE FORM. UPON RECEIPT OF COMPLETED RELEASE FORM AND PAYMENT, ELECTRONIC FILES WILL BE RELEASED. ALL CABLE TIES FOR LOW VOLTAGE SYSTEMS LOCATED IN PLENUMS UTILIZED FOR AIR MOVEMENT THAT ARE NOT INSTALLED IN CONDUIT SHALL BE 25/50 FLAME AND SMOKE RATED, HELLERMANN TYTON T50 R2C2UL OR EQUIVALENT. PLUMBING SYMBOLS EXISTING TO REMAIN EXISTING TO BE REMOVED NEW PIPING CW - COLD WATER HW - HOT WATER V - SANITARY VENT ABOVE GRD./FLOOR ABOVE W - SANITARY WASTE BELOW GROUND SHUT-OFF VALVE PIPE DROP/ PIPE RISE BOTTOM OUTLET TEE TOP OUTLET TEE WALL CLEANOUT CONCENTRIC REDUCER EXISTING TO REMAIN CONNECT TO EXISTING ETR PLUMBING FIXTURE TYPE AND DESIGNATIONL-1 2" V 1 1 /2 " W 4 " W 4" W 1 1 / 2 " V 1 1/2" V 2" V WC-1 L-1 WCO PDI SIZE "A" SINGLE FIXTURE INSTALL PER PDI STANDARDS AND MANUFACTURER'S INSTRUCTIONS MULTIPLE FIXTURES HOT OR COLD WATER SUPPLY IF HORIZONTAL BRANCH IS LESS THAN 20' LONG, PROVIDE ONE WHA AT END OF LINE. IF BRANCH IS GREATER THAN 20' LONG PROVIDE ANOTHER WHA IN MIDDLE, EACH SIZED FOR HALF THE FIXTURE UNITS WATER CLOSET 1.66 GPF DO NOT PROVIDE AIR CHAMBERS. PROVIDE WATER HAMMER ARRESTERS BY SIOUX CHIEF. PRECISION PLUMBING PRODUCTS, WATTS OR APPROVED EQUIVALENT WITH PISTON AND O-RING CONSTRUCTION, HAVING PDI #WH-201, ASSE # 1010, AND ANSI # A112.26.1M CERTIFICATION. INSTALL IN HORIZONTAL OR VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE WITH WATER FLOW DIRECTION IF POSSIBLE. SIZE THE UNITS PER THE TABLES SHOWN ABOVE, BUT NOT LESS THAN WATER CONNECTION SIZE. FIXTURE TOTAL PUBLIC PRIVATE C.W. H.W. TOTAL C.W. H.W. FLUSH VALVE FLUSH TANKWATER CLOSET 1.66 GPF STALL OR WALL URINAL FLUSH VALVE 1.06 GPF LAVATORY FAUCET BATHTUB FAUCET SHOWER HEAD MIXING VALVE BATHROOM GROUP FLUSH VALVE CLOSET BATHROOM GROUP FLUSH TANK CLOSET SERVICE SINK FAUCET LAUNDRY TUBS (1-3) FAUCET TYPE OF SUPPLY CONTROL WEIGHT IN FIXTURE - UNITS 8 8 -5 5 - 5 5 -2.5 2.5 - 4 4 - -- - 2 1.5 1.5 11 1 4 2 3 1.52 1.5 4 2 3 22 1 - - -38 8 - - -36 6 3 3 3 -- - - - -33 3 155-330 114-154 61-113 33-60 12-32 1-11 FIXTURE UNIT LOAD PIPE SIZE PDI SIZE 1/2" 3/4" 1" 1 1/4" 1 1/2" 2"F E D C B A DISHWASHER EQUIPMENT CONNECTION 1.4 -1.4 1.41.4 - 1-31/2"AA WASHER EQUIPMENT CONNECTION 4 3 3 2.253 2.25 ICE MAKER EQUIPMENT CONNECTION 1 1 - -1 1 DRAWING SCHEMATIC BRANCH SIZE PER PLANS (TYP) MA I N ACTUAL INSTALLATION NOTE: ROUTE BRANCH LINE PARALLEL TO MAIN PRIOR TO ELBOWING TO FIXTURE ROUTING. MIN. 12" LENGTH MAIN SHUT-OFF VALVE IN ACCESSIBLE LOCATION BRANCH PROVIDE FIBERGLASS OR ELASTOMERIC INSULATION WITH ALL-SERVICE JACKET WITH VAPOR BARRIER ON ALL SIZES OF DOMESTIC WATER PIPING. PROVIDE FIBERGLASS OR ELASTOMERIC INSULATION ON ALL SIZES OF STORM DRAIN PIPING. REFER TO SPECIFICATIONS FOR FURTHER INFORMATION REGARDING INSULATION. INSTALL ALL ITEMS PER SPECIFICATIONS AND MANUFACTURER'S INSTRUCTIONS. MAINTAIN VAPOR BARRIER ON COLD PIPING BY MEANS OF SEALANT AND TAPE. FLAME-SPREAD AND SMOKE-DEVELOPED INDEXES SHALL NOT EXCEED 25/50. SEAL EXPOSED ENDS OF FIBERGLASS INSULATION WITH ADHESIVE MASTIC. PROVIDE INSULATION 1/4" LARGER ON PIPE WITH HEAT TRACING. PROVIDE ELASTOMERIC OR FIBERGLASS INSULATION ON DOMESTIC COLD & HOT WATER PIPES IN WALLS AND CHASES. MITER THE INSULATION AT TEES AND ELBOWS. SEAL ALL JOINTS WITH ADHESIVE MITER THE INSULATION AT TEES AND ELBOWS SO THAT THERE ARE NO GAPS AT JOINTS IF POSSIBLE. THEN TAPE THEM. OTHERWISE FILL THE GAPS WITH BLANKET FIBERGLASS AND PROVIDE ONE-PIECE PRE-MOLDED PVC FITTING COVERS. TAPE JOINTS OF FIBERGLASS INSULATION PROVIDE A ONE FOOT LENGTH OF NONCOMPRESSIBLE INSULATION AT HANGERS FOR ALL PIPE 2-1/2" AND LARGER REFER TO OTHER DETAILS FOR TREATMENT OF INSULATION AT PENETRATION OF WALLS, FIREFLOORS, FLOORS AND FIREWALLS COVER VALVE BODIES WITH INSULATION, BUT NOT UNIONS SPACE INTENTIONALLY LEFT BLANK FOR CITY APPROVAL / STAMPS ARCHITECT OF RECORD: 8131 METCALF AVENUE SUITE 300 OVERLAND PARK, KS 66204 www.brrarch.com TEL: 913-262-9095 FAX: 913-262-9044 BRR ARCHITECTURE, INC Civil Engineer Structural Engineer Landscape Architect MEP Engineer LANKFORD FENDLER AND ASSOCIATES Developer Seal AT I - P H Y S I C A L T H E R A P Y PR O P O S E D C O M M E R C I A L T E N A N T B U I L D O U T Pr o j e c t : DRAWING SET Description Date Drawn By: Checked By: Sheet Title Sheet No. BRR Job No Consultant Job No THIS SHEET IS INCLUDED FOR INFORMATIONAL PURPOSES ONLY AND IS NOT TO BE SIGNED 20 1 T A H O M A B L V D S E , S U I T E 2 0 7 , YE L M W A 9 8 5 9 7 IOH PLUMBING SCHEDULES, GEN. NOTES, & SYMBOLS P200 1 JMP 1730 Walnut Street Kansas City, Missouri 64108 816.221.1411 Fax: 816.221.1429 L|F+a Project No. COPYRIGHT © LANKFORD|FENDLER+ ASSOCIATES, INC. 25.7700.05 2025 NOT TO SCALE WASTE VENT RISER DIAGRAM NOT TO SCALE WATER HAMMER ARRESTER DETAIL NOT TO SCALE TYPICAL BRANCH LINE TAKEOFF DETAIL NOT TO SCALE PIPE INSULATION DETAIL PERMIT SET 08/06/25 08.06 .2025