Material submittal package-1050
FIRE SPRINKLER EQUIPMENT SUBMITTAL FOR Catherine Remodel 10732 Palisades St. SE Yelm, WA 98597 Element Fire Job # 1050 Table of Contents Section A - Pipe and Fittings 1. CPVC Pipe – Blazemaster 2. CPVC Pipe Fittings – Blazemaster Section B - Hangers 1. CPVC Pipe Hanger – Tolco Fig.’s 24, 28M, & 29 Section C - Valves 1. Pump and Tank - Talco Home Hydrant HH3-150SP Section D - Fire Sprinklers 1. VK494 Residential Concealed Pendent K4.9, 155°/200° – Viking Section E - Alarms and Supervisory Devices 1. Electric Bell – Potter Electric PB Series 2. Backer Box – Potter Electric SECTION A Pipe & Fittings Trusted above all ™ Features • Sizes Available (Nominal): 3/4” (DN20) through 3” (DN80) pipe diameters, with a Standard Dimension Ratio (SDR) of 13.5 as specified in ASTM F442. • Environmental Specifications: Indoor use only. Maximum Ambient Temperature: 150°F (65°C) • Hazen-Williams C Value: 150 • Pressure Data: Working Pressure: 175 PSI (12.1 bar) at 150°F (65°C) • Specifications: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Pipe meets or exceeds ASTM F442. • Certified by NSF International for potable water services. • CPVC pipe from Viking Plastics use compound cell class 23547 (demonstrated highest structural properties). • cULus Listed, FM Approved, New York City (MEA) Approved, LPCB Approved. CPVC PIPE PHYSICAL DATA Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 15’ (4,6 m) length Length Approvals Part Number Inch DN Inch mm Inch mm Lb.Kg.Feet M 3/4”DN20 1.050 26,670 0.874 22,199 2.52 1,14 15 4.6 cULus, FM, NSF 34PIPE 1”DN25 1.315 33,401 1.101 27,965 3.93 1,78 15 4.6 1PIPE 1 1/4”DN32 1.660 42,164 1.394 35,408 6.27 2,84 15 4.6 114PIPE 1 1/2”DN40 1.900 48,260 1.598 40,589 8.22 3,73 15 4.6 112PIPE 2”DN50 2.375 60,325 2.003 50,876 12.89 5,85 15 4.6 2PIPE 2 1/2”DN65 2.875 73,000 2.423 61,500 18.86 8,55 15 4.6 212PIPE 3”DN80 3.500 88,900 2.950 74,900 28.01 12,71 15 4.6 3PIPE Nominal Pipe Size Actual Outside Diameter Average Inside Diameter *Weight per 10’ (3,05 m) length Length Approvals Part Number Inch DN Inch mm Inch mm Lb.Kg.Feet M 3/4”DN20 1.050 26,670 0.874 22,199 1.68 0,76 10 3,05 cULus, FM, NSF 34PIPE10 1”DN25 1.315 33,401 1.101 27,965 2.62 1,19 10 3,05 1PIPE10 1 1/4”DN32 1.660 42,164 1.394 35,408 4.18 1,90 10 3,05 114PIPE10 1 1/2”DN40 1.900 48,260 1.598 40,589 5.48 2,49 10 3,05 112PIPE10 2”DN50 2.375 60,325 2.003 50,876 8.59 3,90 10 3,05 2PIPE10 2 1/2”DN65 2.875 73,000 2.423 61,500 12.57 5,70 10 3,05 212PIPE10 3”DN80 3.500 88,900 2.950 74,900 18.67 8,47 10 3,05 3PIPE10 NOTE: CPVC Pipe is produced in SDR 13.5 Dimensions in accordance with ASTM F442. Standard Dimension Ratio is the ratio of the outside pipe diameter to the wall thickness of the pipe. Blazemaster® is a registered trademark of Lubrizol. Specifications subject to change without notice *Empty pipe weights IMPORTANT: Installers should receive thorough hands-on training in the proper methods of assembly and installation of CPVC products. Trusted above all ™ CPVC Pipe Product Specifications Corrosion resistant CPVC fire sprinkler pipe, when installed in strict accordance with the manufacturer’s design and instal- lation instructions, is UL and c-UL Listed by Underwriters Laboratories for use in the following: • Meets NFPA 13R and 13D standards for residential occupancies as well as NFPA 13 standards for light hazard occupancies. • Residential occupancies up to and including four stories in height as defined by NFPA 13R. • Residential occupancies as defined in the Standard for Sprinkler Systems in One and Two Family Dwellings, NFPA 13D. • Installation of private fire service mains and their appurtenances, NFPA 24. CPVC fire sprinkler pipe from Viking Plastics shall be employed in wet pipe systems only and are not listed for outdoor use. CPVC pipe must never be used in a system using compressed air or other gases. CPVC pipe from Viking Plastics also carries the following enhanced listings and approvals: • According to UL Listing • Can be flush at return air plenums • Exposed system risers NFPA 13D, 13R • Exposed basement NFPA 13D (solid wood joist) • Extended coverage (exposed) y 20’ spacing on pendent in lieu of 15’ y 18’ spacing on sidewall in lieu of 14’ • Use with combustible concealed sprinklers • UL Listed attic sprinkler head (to protect the floor below) • UL Listed attic sprinkler head with wet system piping (feed main and ridge installation) • Exposed sidewall sprinkler listing for exposed pipe & fittings y 24’ extended coverage sidewall sprinkler, 12” drop, 155°F sprinkler head y 18’ extended coverage sidewall sprinkler, 12” drop, 165°F sprinkler head y 16’ extended coverage sidewall sprinkler, 12” drop, 175°F sprinkler head y 14’ standard coverage sidewall sprinkler, 12” drop, 200°F sprinkler head • Factory Mutual Approved* • Factory Mutual Approval exposed • Factory Mutual Approval above drop-in ceilings • Factory Mutual Approval exposed w/Soffi-Steel soffiting covering system New and enhanced listings and approvals are being pursued. Always check with the appropriate Listing and Approval agency for details on current listing parameters. CPVC pipe meets all applicable standards for pressure rated applica- tion as required in ANSI-NSF Standard 14 and complies with ANSI-NSF Standard 61 for health effects and are marked with the NSF-pw end use marking. All CPVC fire sprinkler pipe shall be Listed by Underwriters Laboratories for wet pipe systems, and shall carry a rated working pressure of 175 psi @ 150°F (12 bar @ 65.5°C). *The FM Approval is limited to use in wet pipe fire protection sprinkler systems for light hazard occupancies in both concealed and exposed applications with certain restrictions. Piping must always be installed in strict accordance to the manufacturer’s DESIGN AND INSTALLATION GUIDE, including product storage and handling, joining methods, supporting and bracing, expansion and con- traction allowance and testing, etc. National Fire Protection Association (NFPA) Standards 13, 13D, and 13R must be referenced for design and installation requirements in conjunction with the installation instructions. All CPVC fire sprinkler pipe from Viking Plastics is manufactured in the USA. All CPVC pipe shall be packaged immediately after its manufacture to prevent damage and shall be stored indoors after production, at the manufacturing site, until shipped from the factory. The pipe shall bear the logo of the listing agencies, and shall carry the National Sanitation Foun- dation (NSF) seal of approval for potable water applications. CPVC products are intended for use in areas where the maximum ambi- ent temperature does not exceed 150°F (65.5°C). If the ambient tempera- ture is expected to exceed this limitation, refer to the manufacturer’s DE- SIGN AND INSTALLATION GUIDE for additional information on methods to reduce the pipe exposure temperatures. CPVC pipe is not intended to be installed in outdoor applications. CPVC pipe is intended to be used in wet pipe systems only and have not been investigated for use in dry pipe systems. Special installation and design criteria relative to pipe hanger spacings, piping and sprinkler restraint, sprinkler temperature rating, piping locations, testing procedures and friction loss characteristics are specified in the manufacturer’s installation instructions provided with the pipe. The manufacturer’s installation instructions should be reviewed and the Authority Having Jurisdiction consulted before installation. CPVC BlazeMaster® Fire Protection Fittings 6 Form No. F_032219 19.12.05 Rev 19.3 Specifications and Engineering Data Introduction Viking BlazeMaster® CPVC fire sprinkler products are manufactured from high quality, post-chlorinated polyvinyl chloride (CPVC), a specialty thermoplastic material tested and listed by certifying agencies for use in CPVC fire sprinkler systems. Viking CPVC fire sprinkler products provide unique advantages over traditional metal fire sprinkler systems through superior hydraulics, ease of installation, handling, and quicker assembly using readily available and less expensive tools. These products are also based on technology with a continuous and proven service history of more than forty (40) years. Pressure Rating Viking BlazeMaster® fittings of nominal sizes 3/4" – 3" (20 – 80 mm) are rated for continuous service of 175 psi (1270 kPa) at 150°F (65°C). Approvals Viking BlazeMaster® fittings for fire sprinkler systems »Listed by Underwriters Laboratories (UL) for the United States and Canada under Chlorinated Polyvinyl Chloride Sprinkler Pipe and Fittings - VIWT and VIWT7.EX15419 »FM Global approved for FM Global Group insured properties - Class 1635-Plastic Pipe & Ftngs AS Sys »Meets approval and listing requirements of NFPA 13, 13D, and 13R »Red Book listed by the Loss Prevention Safety Board (LPCB) under automatic sprinkler, water spray and deluge systems - Certificate 1558a to LPS 1260-2.2 »CPVC fittings and Brastic® sprinkler adapters are NSF International listed to NSF/ANSI-61 (health effects) and NSF/ANSI-372 (Lead Free*) for use in potable water applications Nibco BlazeMaster® fittings for fire sprinkler systems »Listed by Underwriters Laboratories (UL) for the United States and Canada under Chlorinated Polyvinyl Chloride Sprinkler Pipe and Fittings - VIWT and VIWT7.EX6309 »Red Book listed by the Loss Prevention Safety Board (LPCB) under automatic sprinkler, water spray and deluge systems - Certificate 878a to LPS 1260-2.2 Use with other Manufacturers' Pipes, Fittings, & Solvent Cements Viking BlazeMaster® CPVC fire sprinkler products are listed by UL to standard 1821. They are also approved by FM to standard 1635. These standards require rigorous testing to ensure the products will function as a component of the assembled fire protection system. For fire protection CPVC pipe the current UL standard is 1821 and FM standard 1635. Viking warrants each Viking BlazeMaster® fitting installed in accordance with local code and regulations with UL listed and/or FM approved CPVC pipe and fittings in compliance with the UL & FM standards. A current list of compatible UL and ULC listed CPVC manufacturers are: Viking (pipe), Harvel (pipe), TYCO Fire Products (pipe & fittings), IPEX (pipe & fittings) and Spears (pipe & fittings). NOTICE: While Viking BlazeMaster® CPVC fire sprinkler products are UL listed for use in combination with other listed manufacturers' products, specific application approvals may not be the same among manufacturers. It is the installer's responsibility to verify suitability of products used in combination according to each manufacturer's installation instructions. Contact Viking if you have questions on any application not addressed in this manual. Engineering Data – Product Specifications Viking BlazeMaster® CPVC fire sprinkler products are made for use with listed CPVC fire sprinkler pipe produced in SDR 13.5 dimensions, as specified in ASTM F442. Viking BlazeMaster® CPVC fire sprinkler fittings are produced in schedule 40 dimensions for sizes 3/4 inch (20 mm) through 1-1/4 inch (32 mm) in accordance with ASTM F438 and schedule 80 dimensions for sizes 1-1/2 inch (40 mm) through 3 inch (80 mm) in accordance with ASTM F439. These products are cULus listed, and FM Approved for a rated working pressure of 175 psi (1200 kPa) at 150°F (65°C) for sprinkler service. Installation Instructions For complete installation instructions refer to the Viking "Installation and Design Manual" on www.vikinggroupinc.com. *Weighted average lead content <0.25%. CPVC FIRE SPRINKLER FITTING 7TA2 8 Form No. F_032219 19.12.05 Rev 19.3 ADAPTERS Grooved Coupling Adapters (G x S) BlazeMaster® Fire Protection Fittings – STANDARD V5001-G Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointABC IN.mm lb.kg IN.mm IN.mm IN.mm V5001-G 1-1/4 33 0.17 0.08 0.83 21 1.04 26 2.98 76 GXS V5001-G 1-1/2 40 0.2 0.09 0.95 24 1.17 30 3.15 80 GXS V5001-G 2 50 0.3 0.14 1.18 30 1.43 36 3.37 86 GXS V5001-G 2-1/2 65 0.52 0.24 1.43 36 1.74 44 3.66 93 GXS V5001-G --65 0.52 0.24 1.43 36 1.74 44 3.66 93 GXS V5001-G 3 75 0.72 0.33 3.5 89 --------GXS Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointLN IN.mm lb.kg IN.mm IN.mm V5018 1x3/4 25x19 0.04 0.02 1.28 33 0.29 7 SPGXS V5018 1-1/4x1 31x25 0.08 0.04 1.41 36 0.29 7 SPGXS V5018 1-1/4x3/4 31x19 0.10 0.05 1.41 36 0.41 10 SPGXS V5018 1-1/2x1-1/4 40x31 0.07 0.03 1.54 39 0.27 7 SPGXS V5018 1-1/2x1 40x25 0.12 0.05 1.54 39 0.39 10 SPGXS V5018 1-1/2x3/4 40x19 0.16 0.07 1.54 39 0.53 13 SPGXS V5018 2x1-1/2 50x40 0.16 0.07 1.66 42 0.27 7 SPGXS V5018 2x1-1/4 50x31 0.20 0.09 1.66 42 0.4 10 SPGXS V5018 2x1 50x25 0.22 0.10 1.66 42 0.52 13 SPGXS V5018 2x3/4 50x19 0.22 0.10 1.66 42 0.64 16 SPGXS V5018 2-1/2x2 65x50 0.24 0.11 1.94 49 0.44 11 SPGXS V5018 2-1/2x1-1/2 65x40 0.36 0.16 1.94 49 0.57 14 SPGXS V5018 2-1/2x1-1/4 65x31 0.40 0.18 1.94 49 0.68 17 SPGXS V5018 2-1/2x1 65x25 0.47 0.21 1.94 49 0.81 21 SPGXS V5018 3x2-1/2 75x65 0.47 0.21 2.42 61 0.6 15 SPGXS V5018 3x2 75x50 0.66 0.30 2.42 61 0.93 24 SPGXS V5018 3x1-1/2 75x40 0.73 0.33 2.42 61 1.03 26 SPGXS BUSHINGS Bushings V5018 9Form No. F_032219 19.12.05 Rev 19.3 Univ. Fig. No. Nominal Size Approx. Wght.Dimension A Joint IN.mm lb.kg IN.mm V5017 3/4"19 0.04 0.02 0.31 8 S V5017 1"25 0.06 0.03 0.39 10 S V5017 1-1/4"31 0.22 0.1 0.56 14 S V5017 1-1/2"40 0.3 0.14 0.68 17 S V5017 2"50 0.42 0.19 0.68 17 S V5017 2-1/2"65 0.62 0.28 1.2 30 S V5017 3"75 0.96 0.44 1.26 32 S Univ. Fig. No. Nominal Size Approx. Wght.Dimension A Joint IN.mm lb.kg IN.mm V5001 3/4 19 0.06 0.03 0.12 3 SXS V5001 1 25 0.08 0.04 0.09 2 SXS V5001 1-1/4 31 0.12 0.05 0.08 2 SXS V5001 1-1/2 40 0.23 0.1 0.27 7 SXS V5001 2 50 0.44 0.2 0.28 7 SXS V5001 2-1/2 65 0.72 0.33 0.2 5 SXS V5001 3 75 1.1 0.5 0.22 6 SXS V5001-R 1x3/4 25x19 0.08 0.04 0.29 7 SXS V5001-R 1-1/4x1 31x25 0.12 0.05 0.35 9 SXS V5001-R 1-1/2x1-1/4 40x31 0.38 0.17 0.51 13 SXS V5001-R 1-1/2x1 40x25 0.36 0.16 0.67 17 SXS V5001-R 1-1/2x3/4 40x19 0.34 0.15 0.8 20 SXS V5001-R 2x1-1/2 50x40 0.49 0.22 0.51 13 SXS V5001-R 2x1 50x25 0.48 0.22 0.75 19 SXS BlazeMaster® Fire Protection Fittings – STANDARD Caps V5017 CAPS Couplings V5001 V5001-R COUPLINGS CROSSES Crosses V5035 V5035-R Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointLN IN.mm lb.kg IN.mm IN.mm V5035 3/4 19 0.12 0.05 0.61 15 0.61 15 SXSXSXS V5035 1 25 0.24 0.11 0.75 19 0.75 19 SXSXSXS V5035 1-1/4 31 0.34 0.15 0.9 23 0.9 23 SXSXSXS V5035 1-1/2 40 0.87 0.39 1.23 31 1.23 31 SXSXSXS V5035 2 50 1.43 0.65 1.53 39 1.53 39 SXSXSXS V5035 2-1/2 65 2.17 0.98 1.75 44 1.75 44 SXSXSXS V5035 3 75 3.12 1.42 1.89 48 1.89 48 SXSXSXS V5035-R 1x1x3/4x3/4 25x25x19x19 0.18 0.08 0.61 15 0.73 19 SXSXSXS 10 Form No. F_032219 19.12.05 Rev 19.3 BlazeMaster® Fire Protection Fittings – STANDARD ELBOWS 45° Elbows V5006 90° Elbows V5007 V5007-R Univ. Fig. No. Nominal Size Approx. Wght.Dimension J Joint IN.mm lb.kg IN.mm V5006 3/4 19 0.06 0.03 0.32 8 SXS V5006 1 25 0.12 0.05 0.39 10 SXS V5006 1-1/4 31 0.18 0.08 0.48 12 SXS V5006 1-1/2 40 0.36 0.16 0.47 12 SXS V5006 2 50 0.54 0.24 0.58 15 SXS V5006 2-1/2 65 1 0.45 0.65 17 SXS V5006 3 75 1.28 0.57 0.76 19 SXS Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointLN IN.mm lb.kg IN.mm IN.mm V5007 3/4 19 0.08 0.04 0.56 14 0.56 14 SXS V5007 1 25 0.14 0.06 0.69 18 0.69 18 SXS V5007 1-1/4 31 0.22 0.10 0.91 23 0.91 23 SXS V5007 1-1/2 40 0.41 0.18 1.06 27 1.06 27 SXS V5007 2 50 0.83 0.37 1.24 31 1.24 31 SXS V5007 2-1/2 65 1.16 0.52 1.5 38 1.5 38 SXS V5007 3 75 1.66 0.74 1.81 46 1.81 46 SXS V5007-R 1x3/4 25x19 0.12 0.05 0.61 15 0.75 19 SXS 11Form No. F_032219 19.12.05 Rev 19.3 TEES BlazeMaster® Fire Protection Fittings – STANDARD Tees V5011 Note: All Viking reducing tees are molded to size, not fabricated. V5011-R Univ. Fig. No. Nominal Size Approx. Wght. Dimensions JointABC IN.mm lb.kg IN.mm IN.mm IN.mm V5011 3/4 19 0.1 0.04 0.57 14 0.57 14 0.57 14 SXSXS V5011 1 25 0.17 0.08 0.69 18 0.69 18 0.69 18 SXSXS V5011 1-1/4 33 0.28 0.12 0.89 23 0.89 23 0.89 23 SXSXS V5011 1-1/2 40 0.58 0.26 1.05 27 1.05 27 1.05 27 SXSXS V5011 2 50 0.82 0.37 1.25 32 1.25 32 1.25 32 SXSXS V5011 2-1/2 65 1.4 0.62 1.53 39 1.53 39 1.53 39 SXSXS V5011 3 75 2.14 0.96 1.84 47 1.84 47 1.84 47 SXSXS V5011-R 3/4x3/4x1 19x19x25 0.14 0.06 0.7 18 0.7 18 0.73 19 SXSXS V5011-R 1x1x3/4 25x25x19 0.16 0.07 0.61 15 0.61 15 0.94 24 SXSXS V5011-R 1x3/4x1 25x19x25 0.2 0.09 0.76 19 0.99 25 0.78 20 SXSXS V5011-R 1x3/4x3/4 25x19x19 0.16 0.07 0.6 15 0.87 22 0.77 20 SXSXS V5011-R 1-1/4x1-1/4x1 33x33x25 0.24 0.11 0.73 19 0.73 19 0.89 23 SXSXS V5011-R 1-1/4x1-1/4x3/4 33x33x19 0.2 0.09 0.6 15 0.6 15 0.89 23 SXSXS V5011-R 1-1/4x1x1-1/4 33x25x33 0.28 0.12 0.88 22 1.03 26 0.87 22 SXSXS V5011-R 1-1/4x1x1 33x25x25 0.24 0.11 0.71 18 0.9 23 0.89 23 SXSXS V5011-R 1-1/4x1x3/4 33x25x19 0.2 0.09 0.61 15 0.76 19 0.89 23 SXSXS V5011-R 1-1/4x1-1/4x1-1/2 33x33x45 0.44 0.2 1.01 26 1.01 26 0.88 22 SXSXS V5011-R 1-1/2x1-1/2x1-1/4 45x45x33 0.46 0.21 0.89 23 0.89 23 1.04 26 SXSXS V5011-R 1-1/2x1-1/2x1 40x40x25 0.54 0.24 0.77 20 0.77 20 0.96 24 SXSXS V5011-R 1-1/2x1-1/2x3/4 40x40x19 0.5 0.22 0.67 17 0.67 17 1.04 26 SXSXS V5011-R 1-1/2x1-1/4x1 40x33x25 0.4 0.18 0.72 18 0.91 23 1.01 26 SXSXS V5011-R 1-1/2x1-1/4x3/4 40x33x19 0.36 0.16 0.6 15 0.78 20 1.02 26 SXSXS V5011-R 1-1/2x1-1/2x2 40x40x50 0.66 0.29 1.3 33 1.3 33 1.14 29 SXSXS V5011-R 2x2x1-1/2 50x50x40 0.86 0.38 1.06 27 1.06 27 1.37 35 SXSXS V5011-R 2x2x1-1/4 50x50x33 0.67 0.3 1 25 1 25 1.28 33 SXSXS V5011-R 2x2x1 50x50x25 0.72 0.32 0.8 20 0.8 20 1.25 32 SXSXS V5011-R 2x2x3/4 50x50x19 0.68 0.3 0.7 18 0.7 18 1.25 32 SXSXS V5011-R 2-1/2x2-1/2x2 65x65x50 1.32 0.59 1.26 32 1.26 32 1.53 39 SXSXS V5011-R 2-1/2x2-1/2x1-1/2 65x65x40 1.21 0.54 1.06 27 1.06 27 1.53 39 SXSXS V5011-R 2-1/2x2-1/2x1-1/4 65x65x33 1.12 0.5 0.91 23 0.91 23 1.53 39 SXSXS V5011-R 2-1/2x2-1/2x1 65x65x25 1.05 0.47 0.74 19 0.74 19 1.53 39 SXSXS V5011-R 3x3x2-1/2 75x75x65 1.71 0.76 1.53 39 1.53 39 1.84 47 SXSXS V5011-R 3x3x2 75x75x50 1.91 0.85 1.26 32 1.26 32 1.84 47 SXSXS V5011-R 3x3x1-1/2 75x75x40 1.39 0.62 1.06 27 1.06 27 1.82 46 SXSXS 18 Form No. F_032219 19.12.05 Rev 19.3 BlazeMaster® Fire Protection Fittings – THREADED INSTASEAL ADAPTERS Sprinkler Adapters with Metal Thread Insert and EPDM Rubber Seat Sprinkler Adapters with Metal Thread Insert and EPDM Rubber Seat V5003-S-BG V5003-2-S-BG Figure 1: Sprinkler Contact on Rubber Seat Univ. Fig. No. Nominal Size Approx. Wght.Dimension A Joint IN.mm lb.kg IN.mm V5003-S-BG 3/4 X 1/2 19x13 1.50 38 C x FNPSH V5003-S-BG 1 X 1/2 25x13 1.88 48 C x FNPSH Univ. Fig. No.Nominal Size Approx. Wght.Dimension A Joint IN.mm lb.kg IN.mm V5003-2-S-BG 3/4 X 1/2 19x13 1.50 38 FTG x FNPSH V5003-2-S-BG 1 X 1/2 25x13 1.85 47 FTG x FNPSH INSTASEAL ADAPTER INSTALLATION INSTRUCTIONS NOTICE InstaSeal adapters can only be used with sprinklers having a K-factor less than or equal to 5.8 (83.6 metric). Pendent and Upright Sprinklers 1. Follow BlazeMaster one-step solvent cement instructions for socket or spigot fittings. Never complete a solvent cement joint with the sprinkler installed into the Instaseal fitting per NFPA 13 requirements. DO NOT OVER APPLY CEMENT WHERE IT COULD OVER SPILL TO RUBBER SEAT. Installer must be properly trained and certified for construction and assembly of BlazeMaster® CPVC piping systems. 2. After proper cure time of cement, make sure sealing surface of rubber is clean and free of any nicks or scratches on sprinkler seal end surface. Use only the thumb and forefinger (finger strength) to start the sprinkler in the lead thread of the Instaseal sprinkler adapter continuing until sprinkler contacts rubber seat. The rubber seat should not be compressed during this step. (Note: also include accessories as supplied by sprinkler manufacturer, such as adjustable cups and escutcheons, on to sprinkler prior to installing sprinkler into adapter fitting.) OK x NO Deformity of rubber seat Brass Insert EPDM Seat CPVC 19Form No. F_032219 19.12.05 Rev 19.3 Tightening torque from touch of sprinkler to seat for proper installation of sprinkler ½ turn CW 14-19 IN-LBS Minimum ¾ turn CW 24-30 IN-LBS Recommended 1¼ turns CW 50-60 IN-LBS Maximum NOTE: Torque values are shown as “Inch-pounds” and not “foot-pounds”. 3. Using sprinkler manufacturer’s recommended wrench, turn sprinkler clockwise (CW) a minimum of one half (½) turn for seal. If sprinkler frame arms require alignment with pipe, continue to rotate CW additional to align, up to the maximum of 1¼ turns from initial seat to sprinkler contact as stated and as shown in Figure 1. NOTICE Do not tighten more than 1¼ turns from initial sprinkler touch to rubber seat. Over-tightening will cause the rubber seat to protrude into the waterway and reduce the K-factor which impedes flow. Additionally, permaent damage to the rubber seat will occur leading to failure and leakage. Refer to Figure 1. Horizontal Sidewall Sprinklers Overview: Horizontal sidewall sprinklers require a specific position including the deflector in the top position and horizontal to the ceiling. Due to the random starting point of threads on both the sprinklers and the adapter fittings it is required that special attention be given to installation of the horizontal sidewall sprinklers. During the initial assembly (Step 2), note the deflector position. If deflector is greater than ½ turn from final position in proper horizontal position, rotate CW only enough to position sprinkler deflector in proper Horizontal position. If deflector position is less than ½ turn to proper position then rotate CW one full turn plus to proper position, maximum 1¼ turns from sprinkler touch of seat. Use proper manufacturer’s sprinkler wrench. 1. Solvent Cement Joining Follow BlazeMaster one-step solvent cement instructions for socket or spigot fittings. Never complete a solvent cement joint with the sprinkler installed into Instaseal fitting per NFPA 13 requirements. DO NOT OVER APPLY CEMENT WHERE IT COULD OVER SPILL TO RUBBER SEAT. Installer must be properly trained and certified for construction and assembly of BlazeMaster Piping system. 2. After proper cure time of cement, make sure sealing surface of rubber is clean and free of any nicks or scratches on sprinkler seal end surface. Use only the thumb and forefinger (finger strength) to start the sprinkler in the lead thread of the Instaseal sprinkler adapter continuing until sprinkler contacts rubber seat. The rubber seat should not be compressed during this step. (Note: also include accessories as supplied by sprinkler manufacturer, such as adjustable cups and escutcheons, on to sprinkler prior to installing sprinkler into adapter fitting.) 3. Determine Sprinkler Position Take note of the position of the sprinkler deflector in relation to the final required position. Determine whether greater or less than one quarter (½) turn is required to reach the required final position. Turn the sprinkler CW with proper sprinkler wrench as required by sprinkler manufacturer. Rotate only to the position where the sprinkler deflector is in the required final installed position. TOP Required Final Position See the manufacturer’s installation instructions for proper location and distance from ceiling. Fig1: HSW Final 12 O’clock Position 3A: Seal and position sprinkler when the top of the delfecltor is in the 12 O’clock position through the 9 O’clock position. 20 Form No. F_032219 19.12.05 Rev 19.3 NOTICE Do not tighten more than 1¼ turns from initial sprinkler touch to rubber seat. Over-tightening will damage the rubber seat causing long term deformation which will lead to failure and leakage. 3B: Seal and position sprinkler when the top of the deflector is between the 9 o’clock position and the 12 o’clock position. Rotate CW 3/4 turnRotate CW 1 full turn Rotate CW 1/2 turn Position of the HSW sprinkler when finger tight and sprinkler is just touching the EPDM rubber seat. Seat the sprinkler and position the deflector by rotating clockwise as indicated above from the position of sprinkler at finger tight touch of EPDM rubber seat initial installation. NOTICE Do not tighten more than 1¼ turns from initial sprinkler touch to rubber seat. Over-tightening will damage the rubber seat causing long term deformation which will lead to failure and leakage. NOTE: For standard horizontal sidewall sprinklers the deflector position holds true as described above. Turn the sprinkler clockwise with the proper sprinkler wrench as required by sprinkler manufacturer. Rotate one full turn plus positioning sprinkler deflector into final required position Fig2: HSW at 12 O’clock through 9 O’clock position. Rotate CW 1 full turn plus to position the top at the 12 O’clock position. Position of the HSW sprinkler when finger tight and sprinkler is just touching the EPDM rubber seat. Seat the sprinkler and position the deflector by rotating clockwise as indicated above from the position of sprinkler at finger tight touch of EPDM rubber seat initial installation. Fig3: HSW at greater than 9 O’clock and less than 12 O’clock position. 22 Form No. F_032219 19.12.05 Rev 19.3 Review – Do's & Don'ts Do’s »Installation should be made only by a qualified installer or contractor in accordance with all applicable codes and requirements. »Read and follow the installation instructions. »Follow recommended safe work practices. »Make certain thread sealants, gasket lubricants, and firestop materials are compatible with CPVC. »Keep pipe and fittings in original packaging until needed. »Cover pipe and fittings with an opaque tarp if stored outdoors. »Follow proper handling procedures. »Use tools specifically designed for use with plastic pipe and fittings. »Use the proper solvent cement and follow application instructions. »Use a drop cloth to protect interior finishes. »Cut the pipe ends square. »Deburr and bevel the pipe end with a chamfering tool. »Rotate the pipe 1/4 turn when bottoming pipe in fitting socket. »Make certain no solvent cement is on sprinkler and adapter threads. »Make certain that solvent cement does not run and plug the sprinkler orifice. »Follow the manufacturer’s recommended cure times prior to pressure testing. »Fill lines slowly and only at a proper pressure. »Bleed the air from the system prior to pressure testing. »Support sprinkler properly to prevent lift up of the through the ceiling when activated. »For threaded rod hangar supports keep within 1/16” near pipe or use surge arrestor. »Install Viking BlazeMaster ® CPVC fire sprinkler products in wet or dry system applications. »Use only insulation and/or glycerin and water solutions for freeze protection. »Allow for movement due to expansion and contraction. »Ensure installers have been properly trained per the Viking BlazeMaster ® CPVC Fire Sprinkler System Installation and Design Manual and renew training every three years at a minimum. Don’ts »Do not use edible oils as a gasket lubricant. »Do not use petroleum or solvent-based sealants, lubricants, or fire stop materials. »Do not use any glycol-based solutions as anti-freeze. »Do not contaminate the CPVC system with cutting oils or compressor oils. »Do not mix glycerin and water solutions in contaminated containers. »Do not use solvent cement that exceeds its shelf life or has become discolored or jellied. »Do not allow solvent cement to plug the sprinkler orifice. »Do not connect rigid metal couplers to CPVC grooved adapters. »Do not thread or groove CPVC pipe. »Do not use solvent cement near sources of heat, open flame, or when smoking. »Do not pressure test with air. »Do not pressure test until recommended cure times are met. »Do not exceed proper pressure for testing. »Do not use ratchet cutters below 50°F. »Do not use CPVC pipe that has been stored outdoors, unprotected and is faded in color. »Do not allow threaded rod to come in contact with the pipe. »Do not install Viking BlazeMaster ® CPVC fire sprinkler products in cold weather without allowing for expansion. »Do not allow puddling of cement in fittings and pipe. »Do not use dull or broken cutting tool blades when cutting pipe. SECTION B Hangers and Sway Bracing CPVC Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 40 B-Line series Fire Protection SolutionsEaton CP V C C l a m p s TOLCO™Fig. 29 - Double Offset Hanger & Restrainer for CPVC Plastic Pipe & IPS Steel Pipe Size Range:Available in 3/4"(20mm)and 1"(25mm)pipe sizes Material:Pre-Galvanized Steel Function:Intended to perform as a hanger and restrainer for CPVC, plastic fire sprinkler pipe. Provides double offset 11/2”(20mm)x 11/2”(20mm)from mounting surface. This design will ease installation by eliminating the need for wood block extension and allow retro-fit attachment of hanger to sprinkler pipe. Features: • Thumb tab provides protection to restrain pipe in rough job site conditions. Tab is not required to be bent for listed installation. • Offset edge eliminates abrasion. • Attaches easily to wood structure with two special #10 x 1” hex head self-threading screws furnished with product. • Can be used as a single offset hanger by aligning "dimples" with top of mounting surface and utilizing two fasteners in two of the three holes provided. Approvals:Underwriters Laboratories Listed in the USA (UL)and Canada (cUL)as a hanger and restrainer to support fire sprinkler systems. Meets and exceeds requirements of NFPA 13, 13R and 13D. Finish:Pre-Galvanized Order By:Figure number and pipe size. Patent Pending Install using a rechargeable electric drill fitted with a 5/16” (7.9mm)socket attachment with the special hex head self-tapping screws provided. Install screws until they bottom out. Pipe can be “snapped” into hanger before or after installation of the screws to the mounting surface. “Thumb tab” may be bent up to provide additional protection to the pipe, but is not required for performance of the hanger / restrainer function. Double Offset Single Offset 1.5” (38.1mm) 1.5” (38.1mm) 1.5” (38.1mm) 1.5” (38.1mm) CPVC Max Hanger Approx. Pipe size Spacing Wt./100 Part No.in. (mm) Ft. (m) lbs. (kg) 29-3/4 3/4"(20) 5’-6”(1.67)18 (8.1) 29-1 1"(25) 6’-0”(1.83)19 (8.6) IPS Max. Hanger Pipe Size Spacing Part No.in. (mm) Ft. (m) 29-3/4 3/4"(20)1’-9”(1.67) 29-1 1"(25)1’-10”(1.83) Reduced Spacing For IPS Pipe CPVC Clamps All dimensions in charts and on drawings are in inches. Dimensions shown in parentheses are in millimeters unless otherwise specified. 38 B-Line series Fire Protection SolutionsEaton CP V C C l a m p s TOLCO™Fig. 28M - Offset Hanger & Restrainer for CPVC Plastic Pipe and IPS Steel Pipe Size Range:3/4"(20mm)thru 2"(32mm) Material:Steel, Pre-Galvanized Function:Designed to be used as a hanger and restrainer for CPVC piping or steel piping where the “stand-off” design will ease installation by eliminating the need for wood blocking. Features: • Flared edge design protects CPVC pipe from any rough or abrasive surfaces • Unique snap-on design holds pipe firmly in place and allows retrofit type of installation • The “Stand-Off” design eliminates the need for wood block extension • Can be installed on horizontal or vertical piping regardless of mounting surface orientation • Attaches easily to wood structure with two hex head self-threading screws furnished with product • Installs easily using rechargeable electrical driver with 5/16”(7.9mm)extension socket eliminating impact tool damage to pipe • Attaches easily to steel, minimum 18 gauge (1.024mm)with (2) 1/4” x 1” tek type self drilling tapping screws • (cULus)Listed as a hanger and a restrainer for fire sprinkler piping Installation Note:When installed in wood structural members and threads from the #10 x 1" screws are exposed, use Fig. 27B (page 36) speed nut to secure Approvals:Underwriters Laboratory Listed in the USA (UL)and Canada (cUL) to support automatic fire sprinkler systems. May be installed into wood using fasteners screws. Meets and exceeds the requirements of NFPA 13, 13R and 13D. Fig. 28M satisfies the UL vertical restraint requirements where needed. Order By:Figure number and pipe size Patent #7,744,042 C A B CPVC Pipe Size A Hole Dia. B C Max Spacing* Approx. Wt./100 Part No.in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) lbs. (kg) 28M-3/4 3/4"(20)2"(50.8)3/16"(4.8)35/16"(84.1)5’-6”(1676)9 (4.1) 28M-1 1"(25)21/8"(54.0)3/16"(4.8)31/2"(88.9)6’-0”(1829)12 (5.4) 28M-11/4 11/4"(32)25/16"(58.7)3/16"(4.8)31/2"(88.9)6’-6”(1981)13 (5.9) 28M-11/2 11/2"(49)27/16"(61.9)3/16"(4.8)37/8"(98.4)7’-0”(2133)14 (6.3) 28M-2 2"(50)25/8"(66.7)3/16"(4.8)47/16"(112.7)8’-0”(2438)15 (6.8) * Required per NFPA 13 for CPVC plastic pipe Hanger and Restraint Application Restraint Restraint Detail A Hanger Application Fig. 27B (2) Required Fig. 27B (1) Required High Side of Hanger IPS Pipe Size Max. Hanger Spacing Part No.in. (mm)Ft. (m) 28-3/4 3/4"(20)1’-9”(1.67) 28-1 1"(25)1’-10”(1.83) 28-11/4 11/4"(32)2-4”(1.98) 28-11/2 11/2"(40)2-9”(2.13) 28-2 2"(50)3-6”(2.44) Reduced Spacing For IPS Pipe SECTION C Valves Fire RESIDENTIAL &o40 E 112TH A COMMERCIAL FIRE PUMP ORE SPECIALISTS TA220 stems PHONE:800-878-8055 WWW.TALCOFIRE.COM y HOME HYD RANT BRAND FIRE PUMP SYSTEM NFPA-13D Packaged Residential Fire Pump & Tank U.S. Patents #8,678,032 & 8,905,069 HH3-150SP 50GPM @ 40PS1 350 Gallon Water Tank 1T Tank Drain %2"(GHT) �2 Overflow Fitting 1 "(FNPT) �3 Auto -Fill Valve 3/4"(FNPT 1.5HP Electric Motor 240 Volt Single -Phase 10.9 Amp (Full Load) 1 %4" Discharge (FNPT) Smart Riser Control System ® Isolation Ball Valve (5) Test Line/System Drain © 40-60 Pressure Switch (7 Pressure Gauge ® Flow Switch (9 Run -Time Controller 10 Discharge Check Valve 11 Suction Shut-off Valve Performance 76 0 4 EG 0 l 0 0 49 T Performance values based on multiple pump tests. Not for certification purposes. GPM 0 20 25 30 35 40 45 50 PSI 55 52 51 50 48 46 43 40 SECTION D Fire Sprinklers FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 1 of 6 Form No. F_012116 20.06.26 Rev 20.2 1. DESCRIPTION Viking Freedom® Residential Concealed Pendent Sprinkler VK494 is a small thermosensitive, glass-bulb residential sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired. The orifice design, with a K-factor of 4.9 (70.6 metric*), allows the sprinkler’s efficient use of available water supplies for the hydraulically designed fire-protection system. The fast response glass bulb operating element and special deflector characteristics meet the challenges of residential sprinkler standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile small-diameter cover assembly installed flush to the ceiling. The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate. The “push-on” and “thread-on” designs of the concealed cover plate assemblies allow easy installation of the cover plate after the system has been tested and the ceiling finish has been applied, while also providing up to 1/2” (13 mm) of vertical adjustment. The cover assembly can be removed and reinstalled, allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. The Electroless Nickel PTFE (ENT) coating has been investigated for installation in corrosive atmospheres and is C-UL-US-EU Listed as indicated in the Approval Charts. The ENT finish is only available for the sprinkler assembly, the cover plate is not plated. 2. LISTINGS AND APPROVALS cULusEU Listed: Category VKKW Refer to the Approval Charts and Design Criteria for C-UL-US-EU Listing requirements that must be followed. 3. TECHNICAL DATASpecifications:Minimum Operating Pressure: Refer to the Approval Chart.Maximum Working Pressure: 175 psi (12 bar). Factory tested hydrostatically to 500 psi (34.5 bar).Thread size: 1/2” (15 mm) NPT Nominal K-factor: 4.9 U.S. (70.6 metric*)Glass-bulb fluid temperature rating: to -65 °F (-55 °C) * Metric K-factor measurement shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Material Standards:Sprinkler Body: Brass UNS-C84400 or QM BrassDeflector: Phosphor Bronze UNS-C51000Deflector Pins: Stainless Steel UNS-S30200Button: Brass UNS-C36000Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400Compression Screw: 18-8 Stainless SteelYoke: Phosphor Bronze UNS-C51000Belleville Spring Sealing Assembly: Beryllium Nickel Alloy, coated on both sides with PTFE TapeCover Adapter: Cold Rolled Steel UNS-G10080, Finish: Clear Chromate over Zinc PlatingShipping Cap: High Density Polyethylene Cover Plate Materials:Cover Plate Assembly: Copper UNS-C11000 and Brass UNS-C26800 or Stainless Steel UNS-S30400Spring: Beryllium NickelSolder: Eutectic Ordering Information: The sprinkler and cover plate must be ordered separately. Refer to Tables 1 and 2. 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, when the temperature around the sprinkler approaches the cover plate’s nominal temperature rating, the cover plate detaches and releases the deflector. Continued heating of the exposed sprinkler causes the heat-sensitive liquid in the glass bulb to expand. When the temperature reaches the sprinkler’s nominal temperature rating, the glass bulb shatters releasing the yoke, pip cap assembly and sealing spring. Water begins flowing through the sprinkler orifice and strikes the deflector form-ing a uniform spray pattern over a specific area of coverage, which is determined by the water supply pressure at the sprinkler, in order to extinguish or control the fire. Replaces Form No. F_012116 Rev 20.1 (Added cover plate options.) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 2 of 6 Form No. F_012116 20.06.26 Rev 20.2 6. INSPECTIONS, TESTS AND MAINTENANCERefer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinkler Model VK494 is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEEFor details of warranty, refer to Viking’s current list price schedule or contact Viking directly. TABLE 1: SPRINKLER ORDERING INFORMATION Instructions: (1) Select a Sprinkler Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the desired Sprinkler Temperature Rating (4) Order a cover plate (refer to Table 2) Example: 20759AE = 200 °F (93 °C) Temperature Rated Sprinkler with a standard Brass finish. Sprinkler Base Part Number1 Size 1: Finishes 2: Temperature Ratings7 NPT Inch Description Suffix Nominal Rating Bulb Color Max. Ambient Ceiling Temperature2 Suffix 20759 1/2 Brass A 155 °F (68 °C)Red 100 °F (38 °C)B ENT5,6 JN 200 °F (93 °C)Green 150 °F (65 °C)E Corrosion Resistant Sprinkler Finish: ENT Accessories Sprinkler Wrenches and tools: A. Heavy Duty Part Number: 14047W/B3 (available since 2006) B. Head Cabinet Wrench Part Number: 140313,4 (available since 2006) C. Optional Concealed Cover Plate Installer Tool Part Number: 144128 (available since 2007) D. Optional Large Concealed Cover Plate Installer Tool Part No. 148678 (available since 2007) Sprinkler Cabinet: Holds up to 6 sprinklers: Part number 01731A (available since 1971). Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. 2. Based on NFPA 13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3. Requires a ½” ratchet (not available from Viking). 4. Also optional for removal of the protective cap. Ideal for sprinkler cabinets. 5. cULus Listed as corrosion resistant. 6. The corrosion resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts. These tests cannot and do not represent all possible corrosive environments. Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the ENT coating is applied to all exposed exterior surfaces, including the waterway. For ENT coated sprinklers, the Belleville spring is exposed. 7. The sprinkler temperature rating is stamped on the deflector. 8. The installer tool is for push-on style cover plates only. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 3 of 6 Form No. F_012116 20.06.26 Rev 20.2 TABLE 2: COVER PLATE ORDERING INFORMATION Instructions: (1) Select a Cover Plate Base Part Number (2) Add the suffix for the desired Finish (3) Add the suffix for the required Cover Plate Nominal Rating. Example: 23190MC/W = 165 °F (74 °C) Temperature Rated, 2-3/4” (70 mm) diameter, Thread-On style, Round Cover Plate with a Painted White finish. 1: Select a Cover Plate Base Part Number3 2: Select a FinishThread-On Style Push-On Style Base Part Number1 Size Inch (mm)Type Base Part Number Size Inch (mm)Type Description Suffix5 23190 2-3/4 (70)Round 23447 2-3/4 (70)Round Polished Chrome F 23174 3-5/16 (84)Round 23463 3-5/16 (84)Round Brushed Chrome F-/B 23179 3-5/16 (84)Square 23482 3-5/16 (84)Square Bright Brass B 231935 2-3/4 (70)Stainless Steel Round 234555 2-3/4 (70)Stainless Steel Round Antique Brass B-/A Brushed Brass B-/B 231835 3-5/16 (84)Stainless Steel Round 234735 3-5/16 (84)Stainless Steel Round Brushed Copper E-/B Painted White M-/W Painted Ivory M-/I Painted Black M-/B 3: Temperature Rating Matrix1,2 Cover Plate Nominal Rating (Required) Temperature Classification Sprinkler Nominal Rating Sprinkler Maximum Ambient Ceiling Temperature2 Suffix 135 °F (57 °C)Ordinary 155 °F (68 °C)100 °F (38 °C)A 165 °F (74 °C)Intermediate 200 °F (93 °C)150 °F (65 °C)C Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price list schedule. 2. The sprinkler temperature rating is stamped on the deflector. 3. Based on NFPA-13, NFPA 13R, and NFPA 13D. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 4. Where a dash (-) is shown in the Finish suffix designation, insert the desired Temperature Rating suffix. See example above. 5. Stainless Steel versions are not available with any finishes or paint. FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 4 of 6 Form No. F_012116 20.06.26 Rev 20.2 Approval ChartViking VK494, 4.9 K-factor Residential Concealed Pendent Sprinkler For systems designed to NFPA 13D or NFPA 13R. For systems designed to NFPA 13, refer to the Design Criteria. For Ceiling types refer to current editions of NFPA 13, 13R or 13D S p r i n k l e r B a s e Part Number 1 SIN NPT Thread Size Nominal K-factor Maximum Water Working PressureInchesmmU.S.metric 2 20759 VK494 1/2 15 4.9 70.6 175 psi (12 bar) Max. Coverage Area 6 W X L Ft. X Ft. (m X m) Flow GPM (LPM) Pressure PSI (bar)Deflector to Ceiling Installation Type Listings and Approvals3,5 Minimum Spacing Ft. (m)155 °F (68 °C), 200 °F (93 °C) Temperature Rated Sprinklers 4 12 X 12 (3.7 X 3.7) 13 (49.2) 7.0 (0.48) Refer to Figure 2 Concealed with Cover Plate Assembly. See Footnote 7. See Footnotes 8, & 9 8 (2.4) 14 X 14 (4.3 X 4.3) 13 (49.2) 7.0 (0.48) 16 X 16 (4.9 X 4.9) 13 (49.2) 7.0 (0.48) 18 X 18 (5.5 X 5.5) 17 (64.4) 12.0 (0.83) 20 X 20 (6.1 X 6.1) 20 (75.7) 16.7 (1.15) Footnotes 1. Part number shown is the base part number. For complete part number, refer to the current Viking price schedule. 2. Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. 3. This chart shows the listings and approvals available at the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Refer also to Design Criteria. 4. Listed by Underwriter’s Laboratories, Inc. for use in the U.S., Canada, and European Union. 5. Meets New York City requirements, effective July 1, 2008. 6. For areas of coverage smaller than shown, use the “Flow” and “Pressure” for the next larger area listed. Flows and pressures listed are per sprinkler. The distance from sprinklers to walls shall not exceed one-half the sprinkler spacing indicated for the minimum “Flow” and “Pressure” used. 7. Other paint colors are available on request with the same listings as the standard finish colors. Stainless Steel cover plates are not available with any finishes or paint. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. Custom colors are indicated on a label inside the cover assembly. Refer to Figure 3. 8. Accepted Cover Plate Finishes are: Polished Chrome, Brushed Chrome, Bright Brass, Antique Brass, Brushed Brass, Brushed Copper, Painted White, Painted Ivory, or Painted Black 7. 9. C-UL-US-EU Listed as corrosion resistant - Electroless Nickel PTFE (ENT) FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 5 of 6 Form No. F_012116 20.06.26 Rev 20.2 DESIGN CRITERIA (Also refer to the Approval Chart.) UL Listing Requirements (C-UL-US-EU): When using Viking Residential Concealed Pendent Sprinkler VK494 for systems designed to NFPA 13D or NFPA 13R, apply the listed areas of cover-age and minimum water supply requirements shown in the Approval Chart. For systems designed to NFPA 13: The number of design sprinklers is to be the four contiguous most hydraulically demanding sprinklers. The minimum required discharge from each of the four sprinklers is to be the greater of the following: • The flow rates given in the Approval Chart for NFPA 13D and NFPA 13R applications for each listed area of coverage, or • Calculated based on a minimum discharge of 0.1 gpm/sq. ft. over the “design area” in accordance with sections 9.5.2.1 or 10.2.4.1.2 of the current edition of NFPA 13. • Minimum distance between residential sprinklers: 8 ft. (2.4 m). NOTE: Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_080415 - Best Practices for Residential Sprinkler Handling and Installation. Also refer to Form No. F_080614 for general care, installation, and maintenance information. Viking sprinklers are to be in-stalled in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA and any other similar Authorities Having Jurisdiction, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Final approval and acceptance of all residential sprinkler installations must be obtained from the Authorities Having Jurisdiction. Sprinkler and Adapter Assembly • Protective cap removed • Use wrench 14047W/B** Step 1: Carefully slide the wrench sideways around the deflector and pins Sprinkler Wrench Part No. 14047W/B** ** A 1/2” ratchet is required (Not available from Viking) 2-1/4” (57 mm) diameter opening required in the ceiling. Step 2: Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 1: Sprinkler Installation and Proper Wrench Usage NEVER install the sprinkler by applying the installation wrench across the frame arms. DO NOT overtighten. Use only the designated sprinkler wrenches, Viking Part Numbers 14047W/B** or 14031**. A leak tight seal should be achieved by turning the sprinkler clockwise 1 to 1-1/2 turns beyond finger tight. Sprinkler wrench flat Sprinkler frame arms FREEDOM® RESIDENTIAL CONCEALED PENDENT SPRINKLER VK494 (K4.9)TECHNICAL DATA The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com Page 6 of 6 Form No. F_012116 20.06.26 Rev 20.2 Figure 2: Sprinkler Dimensions and Cover Installation 1/2” (15 mm) NPT 2- 1 / 4 ” (5 7 m m ) 2-9/16” (65 mm)Maximum 2-1/16” (52 mm)Minimum 2-3/4” (70 mm) or 3-5/16” (84 mm)NOTE: Upon sprinkler activation, the deflector descends to approximately 13/16” (21 mm) below the sprinkler body. Figure 3: Identification of Custom Paint for Concealed Covers All custom color painted cover plates will have an identifying label affixed to the inside of the cover that indicates the custom color and will have a representative sample (a paint dot) of the paint on the label. Figure 4: Square Cover Assembly 3-5/16” (84 mm) F A C T ORY AP P L I E D C USTO M P A I N T COLOR Replaces Form No. F_012116 Rev 20.1 (Added cover plate options.) SECTION E Alarms and Supervisory Devices Size inches (mm) Voltage Model Number Stock Number Current (Max.) Typical dB at 10 ft. (3m) (2) Minimum dB at 10 ft. (3m) (1) 6 (150)12VDC MBA-6-12 1750070 .12A 85 76 8 (200)12VDC MBA-8-12 1750080 .12A 90 77 10 (250)12VDC MBA-10-12 1750060 .12A 92 78 6 (150)24VDC MBA-6-24 1750100 .06A 87 77 8 (200)24VDC MBA-8-24 1750110 .06A 91 79 10 (250)24VDC MBA-10-24 1750090 .06A 94 80 6 (150)24VAC PBA246 1806024*.17A 91 78 8 (200)24VAC PBA248 1808024*.17A 94 77 10 (250)24VAC PBA2410 1810024*.17A 94 78 6 (150)120VAC PBA1206 1806120*.05A 92 83 8 (200)120VAC PBA1208 1808120*.05A 99 84 10 (250)120VAC PBA12010 1810120*.05A 99 86 All DC bells are polarized and have built-in transient protection. * Does not have ULC listing. BELLS PBA-AC & MBA-DC These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power consumption and high decibel ratings. The unit mounts on a standard 4" (101mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 deep weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. PRINTED IN USA PAGE 1 OF 2MFG. #5400776 - REV Y-1 01/13 UL, ULC, and FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) -40° to 150°F (-40° to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells - 4 No. 18 AWG stranded wires DC Bells - Terminal strip Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox Model BBX-1 deep weatherproof backbox Potter Electric Signal Company, LLC • St. Louis, MO, • Phone: 866-572-3005/Canada 888-882-1833 • www.pottersignal.com In outdoor or wet installations, bell must be mounted with weatherproof backbox, BBK-1 or BBX-1. Standard electrical boxes will not provide a weatherproof enclosure. If the bell and/or assembly is exposed to moisture, it may fail or create an electrical hazard. Notes: 1. Minimum dB ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30° to 150°F (-34° to 66°C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. * BELLS PBA-AC & MBA-DC PRINTED IN USA PAGE 2 OF 2MFG. #5400776 - REV Y-1 01/13 A.C. BELLS WHITE (IN) BLACK (IN) WHITE (OUT) BLACK (OUT) FROM CONTROL PA NEL OR PRECEDING BELL CAUTION: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. NOTES: 1. WHEN USING AC BELLS, TERMINATE EACH EXTRA WIRE SEPA RATELY AFTER LAST BELL. 2. END-OF-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. DWG# 776-3 5 3/4” (146) 1 5/8” (41) DWG# 776-2 3 3/8” (86) 4 1/4” (108) 3 3/8” (86) 5” (127) Weatherproof Backbox Dimensions Inches (mm) Fig. 2 Box has one threaded 1/2" conduit entrance Wiring (rear view) Fig. 3 +_FA CP To Next Device or End-of-Line Resistor Installation 1. The bell shall be installed in accordance with NFPA 13, 72, or local AHJ. The top of the device shall be no less than 90" AFF and not less than 6" below the ceiling. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority having jurisdiction). 2 11/16” (68)DWG# 776-1 10” (250)8” (200)6” (150) Bells Dimensions Inches (mm) Fig. 1 2” (51 ) 4 1 / 4 ” ( 1 0 8 ) 3 3 / 8 ” ( 8 5 . 9 ) BBX-1 Failure to install striker down will prevent bell from operating.