Loading...
10732 Palisades St. ST Sprinkler planGarage W D Fur.WH Bedroom Bedroom Bedroom Living Room Dining Room Kitchen Bath Laundry Bath Bedroom Bedroom Bath Storage 26 241¼1 1¼ 1¼ 1¼ 1¼ 1¼ 1¼ 1 1 1 1 1 11 1 11 1 1 1 1 1 1 1 1 1 1 1 1¼ 1 1 1 1 1 1 1 1 1 20123 Finished Attic 211 1 11 1 1 111 118 PUMP & TANK 46 TANK DRAN ½" (GHT) 45 RISER LEGEND 1.5 HP PUMP 1 GPM PSI 55 6 - 10 40 2 - 2 - 48 Performance values based on multiple pump tests. Not for certification purposes. 8 - 9 6 Performance: DISCHARGE CHECK VALVE PUMP SPECIFICATIONS ALL WIRING OF PUMP, SWITCHES, AND BELL TO BE BY OTHERS 11- 30 1 - 3 350 GALLON TANK WATER PRESSURE SWITCH 3 - 50 OVERFLOW FITTING 1" (FNPT) 12 7 2 43 4 - RISER NOTES8 3/4" FILL LINE TO BE PROVIDED BY OTHERS 1.5 HP ELECTRIC MOTOR SYSTEM DRAIN / TEST LINE 3 - 35 10.9 AMP (FULL LOAD) 4 PRESSURE GAUGE 11 12-5 9 - AUTO-FILL VALVE 3/4" (FNPT) 10- 1 - 0 40 3 -2 - 1¼" BALL VALVE 50 5 - 25 SUCTION SHUT-OFF VALVE 240 VOLT SINGLE PHASE 20 7 - 51 FLOW SWITCH 52 Hydraulic Information Remote Area 1 OCCUPANCY CLASSIFICATION Residential DENSITY (gpm/ft²)0.05 for 900ft² (Actual 320ft²) TOTAL HOSE STREAMS 100.00 DRY CAPACITY 0.00gal TOTAL HEADS FLOWING 2 K-FACTOR 4.9 TOTAL WATER REQUIRED 26.40 TOTAL PRESSURE REQUIRED 21.413 BASE of RISER (gpm)26.40 BASE of RISER (psi)21.413 SAFETY MARGIN (psi)+28.492 (57.1%) SCOPE OF WORK: INSTALL NEW NFPA 13D FIRE SPRINKLER SYSTEM THROUGHOUT AN EXISTING RESIDENCE. GENERAL NOTES: 1. IT IS THE RESPONSIBILITY OF THE OWNER TO MAINTAIN THE INTEGRITY OF THE SPRINKLER SYSTEM. 2. ALL MATERIAL AND EQUIPMENT TO BE NEW AND UL AND/OR FM APPROVED. 3. ALL SYSTEM PIPING SHALL BE TESTED AT STATIC PRESSURE PER NFPA 13D. 4. PIPE HANGER AND METHOD OF HANGING TO BE IN ACCORDANCE WITH NFPA #13D (2019). 5. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER SYSTEM. 6. STRUCTURAL ADEQUACY OF THE BUILDING TO SUPPORT THE SPRINKLER PIPING IS THE RESPONSIBILITY OF THE OWNER AND/OR HIS STRUCTURAL REPRESENTATIVE. 7. ALL FIRE ALARMS, WIRING AND MONITORING ARE TO BE INSTALLED BY OTHERS. DESIGN NOTES: 1. RISER ASSEMBLY / PUMP AND TANK TO BE LOCATED IN THE GARAGE (ELEMENT FIRE SPRINKERS START POINT). 2. SYSTEM TO BE DESIGNED IN ACCORDANCE WITH NFPA #13D (2019) SINGLE FAMILY RESIDENCE. 3. PLAN SUBMITTAL TO AND APPROVAL BY City of Yelm. 4. MATERIALS PER NFPA #13D STANDARD. 5. TESTING PER NFPA #13D AND City of Yelm. 6. TYPICAL HANGERS TO BE TOLCO FIG. 24, 28M & 29 UNLESS NOTED OTHERWISE FIELD NOTES: 1. ALL NEW PIPE IS TO BE CPVC. 2. ALL NEW FITTINGS ARE TO BE CPVC. 3. DESIGN CRITERIA TO BE BASED ON NFPA 13D: A. SPRINKLER SPACING NOT TO EXCEED (16' x 16') OR (8') OFF OF WALLS MAXIMUM. B. MINIMUM PRESSURE AND FLOW FOR SPRINKLERS SPACED 16' x 16' = 13 GPM @ 7.0 PSI. INDICATES BATHROOM OR CLOSET MEETS THE REQUIREMENTS OF NFPA 13D (2019) 8.3.2 or 8.3.3 AND SPRINKLER PROTECTION SHALL NOT BE REQUIRED. TOLCO FIG. #28M NTS HANGER TYPE CP TOLCO FIG. #24 NTS HANGER TYPE CP ATTIC INSULATION (BY OTHERS). BOTTOM CHORD OF TRUSS USE BATT TYPE INSULATION GWB CEILING (BY OTHERS). USE BATT TYPE TENT FIRE SPRINKER PIPEBEFORE INSULATING ATTIC WET PIPE FREEZE CPVC FIRE SPRINKLER PIPE FOR TENTING INSULATION FOR TENTING. NTS PROTECTION DETAIL NTS HANGER TYPE CP TOLCO FIG. #29 Sprinkler Legend Symbol Manufacturer SIN Model Quantity K-Factor Type Size Response Finish Temperature Note Viking VK494 Freedom 22 4.9 Pendent ½Quick Brass 155°F Viking VK494 Freedom 1 4.9 Pendent ½Quick Brass 200°F Total = 23 FP1 1 A DRAWING SYMBOLS: AHJ: REV#BY JOB NUMBER:REVISIONS: DATE: REVIEWED BY: DRAWN BY: DESCRIPTION SCALE: SHEET NUMBER: DATE CONTRACT WITH: - PIPE HANGER DATUMFFCCACOUPLING #1 L 0'-10" (SEE CHART) NUMBER - ELEVATION - PIPE SIZE DATUM 1AC - BRANCHLINE CL PIPE TAG 10'-10" TS OF PIPE TO- CENTERLINE A.1 9'-0 - HYDRAULIC NODE FF - WELDED - RIGID GROOVED - FLEXIBLE GROOVED L OF PIPE TODECK - ELEVATION TS L 0'-10" DECK COUPLING & LENGTH CUT - SEISMIC BRACE - CENTERLINE JWH Catherine Remodel 1050 AS NOTED 08/27/25 Yelm, WA 98597 1 of 1 10732 Palisades St. SE City of Yelm Auburn, WA 98092 : Catherine Gathara - 253-341-3362 5122 Nathan Loop SE Catherine Gathara 110 Williams Blvd. NE Orting, WA 98360 (253) 405-4562 VICINITY MAP SCALE: NTS Level 1 - SPRINKLER PIPING PLAN SCALE: 3/16" = 1'-0"NORTHNO R T H SCALE: NTS RISER DETAIL Street View SCALE: NTS Level 2 - SPRINKLER PIPING PLANNORTHSCALE: 3/16" = 1'-0" "OFFSET" HANGER & RESTRAINER HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE FOR CPVC AND IPS PIPE HARDENED HEX HEAD SELF THREADING SCREW IS FURNISHED WITH THE HANGER AND IS THE MINIMUM FASTENER SIZE ACCEPTABLE CPVC DOUBLE FASTENER STRAP TYPE HANGER "DOUBLE OFFSET" HANGER & RESTRAINER HARDENED HEX HEAD SELF THREADING SCREWIS FURNISHED WITH THE HANGER AND IS THEMINIMUM FASTENER SIZE ACCEPTABLE X THIS AREA HAS BEEN HYDRAULICALLY CALCULATED TO DELIVER A RESIDENTIAL COVERAGE (NFPA 13D)OF: REMOTE AREA #1 13 GPM @ 7.0 PSI USING 16' x 16' HEAD SPACING 26.40 GPM @ 21.413 PSI SYSTEM DEMAND: 08/27/2025