Loading...
PlotPlan_YRR-000-00-016_16300-JenkinsAveSERD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RDRDRDRDRDRDRDRD RD RD RD RD RD RD RD RD RD RD 16 . 1 8 GARAGE CLEANOUT ROOF LINE EX. SEWER PROPOSED CONTOUR PROPOSED TREE GF: 342.0 FF: 342.5 27 . 8 4 20 . 1 6 RMT 1500 STEP TANK PATIO SEWER STUB WATER METER PORCH EX. STORM EX. RECLAIMED WATER EX. WATER CONNECT TO STORM PIPE SLEEVE STORM CLEANOUT ROOF DRAIN LINE LOT 17 GAS METER CONTROL PANEL ELECTRIC METER REQUIRED CONCRETE PAD PER DETAIL JENKINS AVE SE 7.55' 7.4' 5' 5' 27 . 8 2 5' BSBL 25 ' B S B L 5' BSBL 15 ' B S B L 40' 42' 46 ' 10 ' P. U . E . 7.63' 5' 20 . 1 6 ' G A R A G E 20' LOT 16 4,721± SF N3 7 ° 2 0 ' 0 4 " W 9 0 . 0 0 N52°28'39"E 52.31 N3 7 ° 3 1 ' 2 1 " W 9 0 . 0 0 N52°28'39"E 52.61 3 4 2 342 9/4/2025 9:43 AM CFEMLING J:\2025\25103\PLOT PLANS\LOT 16.DWG SITE 25103 DESIGN 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING SURVEYING LEGEND P.U.E.PUBLIC UTILITY EASEMENT S.D.E.PRIVATE STORM DRAIN EASEMENT NOTE NO FOOTING DRAINS USED DUE TO INFILTRATION DIRECTLY INTO THE GROUND. CONCRETE PAD LOT 16 2776 WHIDBEY (B) 9/4/25 AREAS 16300 JENKINS AVE SE SITE AND UTILITY PLAN ADDRESS:16300 JENKINS AVE SE LOT#:16 PROJECT#: PERMIT#: RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RDRDRDRDRDRDRDRD RD RD RD RD RD RD RD RD RD RD 16 . 1 8 GARAGE CLEANOUT ROOF LINE EX. SEWER PROPOSED CONTOUR PROPOSED TREE GF: 342.0 FF: 342.5 27 . 8 4 20 . 1 6 RMT 1500 STEP TANK PATIO SEWER STUB WATER METER PORCH EX. STORM EX. RECLAIMED WATER EX. WATER CONNECT TO STORM PIPE SLEEVE STORM CLEANOUT ROOF DRAIN LINE LOT 17 JENKINS AVE SE 7.55' 7.4' 5' 5' 27 . 8 2 5' BSBL 25 ' B S B L 5' BSBL 15 ' B S B L 40' 42' 46 ' 10 ' P. U . E . 20 . 1 6 ' G A R A G E 20' LOT 16 4,721± SF N3 7 ° 2 0 ' 0 4 " W 9 0 . 0 0 N52°28'39"E 52.31 N3 7 ° 3 1 ' 2 1 " W 9 0 . 0 0 N52°28'39"E 52.61 3 4 2 342 9/4/2025 9:43 AM CFEMLING J:\2025\25103\PLOT PLANS\LOT 16.DWG TESC 25103 DESIGN 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING SURVEYING LEGEND P.U.E.PUBLIC UTILITY EASEMENT S.D.E.PRIVATE STORM DRAIN EASEMENT NOTE NO FOOTING DRAINS USED DUE TO INFILTRATION DIRECTLY INTO THE GROUND. CONCRETE PAD LOT 16 9/4/25 TESC PLAN CONTRACTOR SHALL INSTALL SILT FENCE USING BEST MANAGEMENT PRACTICES ALL OPEN AREAS SHALL BE COVERED WITH MULCH, THICK STRAW, OR PLASTIC SHEETING TEMPORARY CONSTRUCTION ENTRANCE 2776 WHIDBEY (B) 16300 JENKINS AVE SE