FS PLANS
3 2 1
GW
B
C
O
V
E
R
E
D
C
O
L
U
M
N
ACT CEILING
ACT CEILING
GWB CEILING
13'-5"
AFF
12'-1"
AFF
15
'
-
1
"
8'
-
0
"
8'
-
1
1
"
10
'
-
7
.
5
"
S
3
2
52
'
-
0
.
5
"
18
'
-
5
.
5
"
0'
-
7
"
7'
-
1
0
.
5
"
48" EASY FLEX, U.N.O.
NEW 1"
ELBOW
EXISTING 1"
ACT CEILING
REC. SSP
EXISTING
BRANCH
LINE
NEW 1"
PER PLAN
NEW 1"
ELBOW
NEW 1"
PER PLAN
NEW 1"
ELBOW
48" EASY FLEX, U.N.O.
ACT CEILING
REC. SSP
NEW 2"
STRAP
24
G
4
N
1
1
.
7
K
28LH(338/169)
28LH(338/169)
28LH(338/169)
3 3 3 3 3
2
2
2
2
2
2
2
2
2
2
22
1
111 104
MECH.
103
TOILET
106
ACT 9'-5" AFF
CONCIERGE
102
N.I.C.
N.I.C.
N.I.C.
EXISTING
10'-8" ACT
ACT 8'-11" AFF
BATHROOM GWB 8'-0" AFF
N.I.C.
LINTEL 8'-5" AFF
S
ACT 10'-7.5" AFF
1
0-6
1(
2
-
6
)
FLEX B FLEX A
72" FLEX B
1'
-
8
.
5
"
S
N.I.C.N.I.C.N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.N.I.C.N.I.C.N.I.C.N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.
N.I.C.N.I.C.
1(2
-
6
)
1
0-6
PLUG 1" OUTLET ON
EXISTING TEE & CUT IN
STRAP ON EXISTING
BRANCHLINE FOR NEW
FLEX
B C
36'-11"
108'-9.5"
ABOVE FINISHED FLOOR
BOTTOM OF TRUSS
BOTTOM OF PURLIN
BOTTOM OF JOIST
BOTTOM OF DECK
BOTTOM OF BEAM
INSIDE FACE OF WALL
UNLESS NOTED OTHERWISE
NO AUTO. SPRINKLERS
OUTSIDE FACE OF WALL
ABBREVIATIONS
BOP
CTS
BOT
OFOW
NAS
IFOW
UNO
FO
CUT TO SUIT
FIELD ORDER
AFF
BOD
BOJ
BOB
HYDRAULIC CALCULATION NODE
FLEXIBLE COUPLING
RIGID COUPLING
ELEVATION ABOVE REFERENCED
2-WAY EARTHQUAKE SWAY BRACE
4-WAY EARTHQUAKE SWAY BRACE
CENTERLINE OF PIPE TO REFERENCED
LETTER INDICATES TYPE
LETTER INDICATES TYPE
STRUCTURE IN INCHES
HANGER LOCATION
POINT IN FEET AND INCHES
A
A
BOD
12
SYMBOL LEGEND REVISIONS
REASON FOR REVISIONNO.BYDATE
CONTRACT WITH:
PROJECT MANAGER :
OFFICE PHONE :
EMAIL :
SUPERINTENDENT :
PHONE :
EMAIL :
CELL PHONE :
CERTIFICATE OF COMPETENCY STAMP
SYM MANUFACTURER S.I.N.TYPE MODEL SPRINKLER
FINISH
ESCUTCHEON
FINISH
ORIFICE
SIZE
THREAD
SIZE
TEMP.
RATING QUANTITY
SPRINKLER LEGEND
OF
FAX: ( 253 ) 926 - 2350
CONTR. REG. NO. SMITHFS1360T
TACOMA, WA 98424
1106 54th AVE EAST
SMITH FIRE SYSTEMS, INC.
Bus: ( 253 ) 926 - 1880
DATEDESIGNER SHEET JOB NO.
OF
PROJECT MGR
FAX: ( 253 ) 926 - 2350
CONTR. REG. NO. SMITHFS1360T
TACOMA, WA 98424
1106 54th AVE EAST
SMITH FIRE SYSTEMS, INC.
Bus: ( 253 ) 926 - 1880
DATEDESIGNER SHEET JOB NO.PROJECT MGR
TI25069
ATI YELM
201 TAHOMA BLVD SE, STE 207
YELM, WA
1 1TANNER R 10/8/25LANE L.
SPRINKLER PLANN
BUILDING SECTION
1. ALL STEEL PIPE TO BE AS FOLLOWS UNLESS NOTED OTHERWISE:
2. ALL GROOVED COUPLINGS TO BE RIGID TYPE UNLESS NOTED ( ||| ) WHICH ARE FLEXIBLE.
SMITH FIRE SYSTEMS (SFS) WILL MODIFY THE EXISTING SPRINKLER SYSTEM TO
ACCOMMODATE THE NEW WALLS AND CEILINGS.
CLARIFICATIONS:
1.STARTING AT EXISTING OUTLETS ON THE EXISTING SPRINKLER SYSTEM BRANCH
LINES OR MAIN AT THE ROOF.
2.ALL AREAS PROTECTED BY A WET PIPE SYSTEM MUST BE MAINTAINED AT 40°F IN
ORDER TO PREVENT FREEZING.
3.SPRINKLER MODIFICATIONS ARE BASED UPON HAVING ADEQUATE PRESSURE
AVAILABLE AT THE POINT OF CONNECTION
4.MATERIALS INSTALLATION AND DESIGN PER NFPA 13 STANDARDS AS SELECTED BY
SFS.
5.ROUGH-IN OF NEW SPRINKLER DROPS MUST BE COMPLETED BEFORE NEW WALLS OR
CEILINGS ARE INSTALLED.
6.ALL WORK TO BE PERFORMED DURING NORMAL BUSINESS HOURS (7AM-4PM).
7.UPRIGHT SPRINKLERS WILL NOT BE REMOVED / MODIFIED WHEN NEW PIPE IS
INSTALLED FOR THE NEW PENDANT SPRINKLERS.
8.EXISTING CEILING REMOVAL BY OTHERS WILL BE REQUIRED TO ACCESS EXISTING
SPRINKLER PIPING AT THE ROOF LEVEL.
EXCLUSIONS:
1.SAFE OFF OR A SEPARATE DEMO TRIP IS NOT INCLUDED UNO.
2.FLOOR MUST BE FREE AND CLEAR OF MERCHANDISE, STOCK, RACKING OR
CONSTRUCTION MATERIALS TO ALLOW FOR ACCESS TO PIPE AT THE STRUCTURE.
3.CUTTING PATCHING OR FIRE CAULKING OF WALLS, CEILINGS, OR FLOORS
4.ACCESS PANELS OF ANY KIND.
5.DOH, FM, INSURANCE, OR OTHER OUTSIDE REVIEW REQUIREMENTS, APPROVALS OR
FEES
6.HEAT TRACE OR INSULATION OF ANY KIND
7.NO WORK HAS BEEN INCLUDED IN THE EXISTING BUILDING OUTSIDE OF THE AREAS
OF NEW CEILING WORK INDICATED ON THE RCP.
8.PAINTING OR LABELING OF PIPE.
9.REPLACEMENT OF PAINTED, DAMAGED, OR CORRODED SPRINKLERS.
10.ELECTRICAL OR ALARM WORK OF ANY KIND.
11.BACKFLOW INSTALLATION, MODIFICATION, OR CERTIFICATION (IF REQUIRED)
12.REPAIRS OR MODIFICATIONS TO THE EXISTING SYSTEM BEYOND THE SCOPE
DESCRIBED ABOVE.
13.FIRE WATCH OR TEMPORARY SPRINKLER PROTECTION DURING CONSTRUCTION.
14.MODIFICATIONS REQUIRED TO ACCOMMODATE THE WORK OF OTHER TRADES
15.STRUCTURAL ANALYSIS, SEISMIC INVESTIGATION, OR PE REVIEW UNO
16.UNDERGROUND WORK OF ANY KIND
17.INFECTIOUS CONTROL MEASURES OTHER THAN THAT PROVIDED BY THE GENERAL
CONTRACTOR, INCLUDING WORKING INSIDE CONTAINMENT BOX.
18.OVERTIME OR AFTER HOURS.
19.UPRIGHT SPRINKLER PROTECTION FOR NON-COMBUSTIBLE SPACE ABOVE THE
CEILING LEVEL DURING OR AFTER CONSTRUCTION.
SCOPE OF WORK
GENERAL NOTES
AREA MAP
N
NTSNTS
NEW
UNCHANGED
EXISTING
SSP CHR CHR
TOTAL NEW 3
1/2"
UNCHANGED SSU
35.6KRA1414RELIABLESSP REC F1FR-56 CHR CHR F1 1/2"155°
BRZ ---1/2"
155°
155°
FITTER/LISTER NOTES
5.6K
5.6K
1.ALL SPRINKLERS TO BE CENTERED IN 2' DIRECTION ONLY OF 2' x 4' TILES
2.EXCLUDING WORK ON OVERTIME OR AFTER HOURS.
3.EXCLUDING RELOCATING OR MODIFYING THE EXISTING SPRINKLER
SYSTEM TO ACCOMMODATE THE WORK OF OTHER TRADES.
4.CEILING GRID REMOVAL BY OTHERS MAY BE REQUIRED TO ACCESS
EXISTING OVERHEAD SPRINKLER PIPE.
CAPACITY
IN GALLONS
WEIGHT OF
WATER / PIPEEND PREP TYPES ALLOWEDINTERNAL
DIAMETER
WALL
THICKNESS
PIPE
SIZE SCHEDULE
STEEL PIPE ASTM A - 795 OR BETTER
** WALL THICKNESS PER NFPA # 13
DESIGN CRITERIA:
PER NFPA 13 2019 AND THE CITY OF YELM
EXISTING CRITERIA:
PHYSICAL THERAPY - LIGHT HAZARD CLASSIFICATION
NEW DESIGN CRITERIA:
PHYSICAL THERAPY - LIGHT HAZARD CLASSIFICATION
ALARM PHONE :
ALARM CODE :
FIRE DEPARTMENT :
FIRE DEPT. PHONE :
MAINTENANCE CONTACT :
MAINTENANCE PHONE :
ALARM COMPANY :
ALARM PASSWORD :
BUILDING INFORMATION
__________
__________
__________
__________
__________
__________
__________
__________
TENANT IMPROVEMENT:
THIS PROJECT IS A TENANT IMPROVEMENT. THIS FACILITY HAS ALREADY BEEN PROTECTED
BY A FIRE SPRINKLER SYSTEM. SMITH FIRE SYSTEMS IS ADDING AND/OR RELOCATING
SPRINKLER HEADS TO ACCOMMODATE THE NEW TENANT WALL, CEILING, LIGHTING, AND
HVAC LAYOUT. ALL WORK WILL BE DONE WITHOUT AFFECTING THE CAPABILITY OF THE
EXISTING SYSTEM; THEREFORE, NO NEW HYDRAULIC CALCULATIONS ARE NECESSARY.
NIPPLETYPEMAKE
EASY 1/2"
LEN
48"
FLEX LEGEND
QNTY
2HI PERF.
BRKT
ACT
EASY 1/2"60"HI PERF.ACT
EASY 1/2"72"HI PERF.ACT
EASY 1/2"x9"48"HI PERF.GWB
90°x1/2" = 90° NIPPLE 6" LONG
TEK = (2) 1/4"x1.5" TEK SCREW
BRACKET LEGEND:
GWB = T-BAR, OTBS ENDS, AND OSSB CLAMP
ACT = STANDARD OGSB BRACKET
WDS = (2) #10x1.5" WOOD SCREW
EASY 1/2"x9"60"HI PERF.GWB
EASY 72"1HI PERF.GWB
SCRW
NA
NA
NA
TEK
TEK
TEK
9"x1/2" = 9" LONG x 1/2" EXTENDED NIPPLE
4'BAR = T-BAR, OTBS ENDS, AND OSSB CLAMP
1/2"x9"
2.05 0.0441.0490.133401 THREADED, CUT GROOVED, ROLL GROOVED, PLAIN END, POLISHED
DRY SPRK
A-DIM.
---
---
---
BRENA RODRIGUEZ
913-387-2847
816-679-7841
BRODRIGUEZ@ROYALSOLVES.COM
TONY RIVERA
541-274-9336
ROYAL CONSTRUCTION
19175 METCALF AVE
OVERLAND PARK, KS 66085
NEW STRAP OUTLET
SYMBOL LEGEND
S
NEW MECHANICAL TEE OUTLETMT
RELOCATED EXISTING SPRINKLERR
EXISTING THREADED OUTLETP
EXISTING SYSTEM COMPONENT(E)
NEW 1" PLUG
NEW 1/2" PLUG
WALL LEGEND
EXISTING WALL
NEW WALL TO CEILING
NEW FULL HEIGHT WALL
NEW LOW WALL
NEW SOFFIT WALL
PIPE LEGEND
NEW SPRINKLER PIPE
EXISTING SPRINKLER PIPE
RELOCATED EXISTING PIPE
NEW FLEXDROP
RELOCATED EXISTING FLEX
HCB = T-BAR, HCB ENDS, AND OSSB CLAMP
N.I.C.NOT IN CONTRACT
TOE THREAD ONE END
GOE GROOVE ONE END
TBE/TT THREAD BOTH ENDS
TENANT IMPROVEMENT
FACING SOUTHWEST
SITE MAP
N
NTS
0
SCALE 1/4"=1'-0"
4 8
FLEX A
FLEX B
AREA OF WORK
ON SECOND
FLOOR
RISER ROOM
TA
H
O
M
A
B
L
V
D
S
E