SPS-H4H_Yelm-1345_250526_2021-WSEC_Heating-System-Sizing-WorksheetSimple Heating System Size: Washington State Project Information Contact Information Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Deisgn Temperature 17 Instructions Lacey Design Temperature Difference (∆T) 53 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft) 1,198 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft) 8.5 10,183 Glazing and Doors U-Factor X Area = UA Instructions U-0.25 0.250 235 58.75 Skylights U-Factor X Area = UA Instructions 0.50 0 0.00 Insulation Attic U-Factor X Area = UA Instructions R-60 0.024 680 16.32 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions No Vaulted Ceilings in this project.----- Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions R-20 STD +R-5 ci 0.045 1,198 53.91 Floors U-Factor X Area UA Instructions No Floors above unconditioned spaces.----- Below Grade Walls and Slabs (see Figure 1)Wall U-Factor X Area UA Instructions None ---- Select nearest slab depth Slab F-Factor X Length UA ---- Slab on Grade (see Figure 1)F-Factor X Length UA Instructions R-10 Fully Insulated 0.360 111 39.96 Location of Ducts Instructions Conditioned Space Duct Leakage Coefficient 1.000 Sum of UA 168.94 Envelope Heat Load 8,954 Btu / Hour Sum of UA x ∆T Air Leakage Heat Load 5,829 Btu / Hour Volume x 0.6 x ∆T x 0.018 Building Design Heat Load 14,783 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 14,783 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 18,478 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump Wall & Slab Depth This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 and 2021 Washington State Energy Code (WSEC) . This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. SPS Habitat for Humanity - 1345 Townhome Longmire St SE Yelm, WA 98597 Jason Taellious o.b.o. Artisans Group Architecture jason@artisansgroup.com 206.639.7098 This tool is for the permitting purposes only. A Manual J calculation is required to meet the requirement of the Washington State Energy Code. Above Grade Below Grade Figure 1. All Other Systems Heat Pump (07/01/13)