HomeMy WebLinkAbout105108817_YelmPlazaTHIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
10
5
1
0
8
8
1
7
Owner / Developer Contact Info
officeATTN:
Yelm Plaza LLC
18230 E Valley HWY Ste #195
Kent, WA, 98032
Caleb Lee 206-499-5086
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
PROJECT
LOCATION
Vicinity Map (Lat,Long: )
OVERHEAD CIRCUIT MAP
SCALE: 6"= 1 MILE
SITE PLAN
SCALE: 1" = 40'
JOB SITE
CIRCUIT FEET ADDED: 0'
Sq. Footage: N/A
Panel Size: (5) 200AMP
Heat Type:ELEC
Est. Demand: 18.73 kW
LRC: 65
% V. Drop:4.9%
% Flicker:3.6%
N
PERM METER
PSE Locates Req'd
Developer Locates Req'd Yes
No
Yes
YesFlagging Req'd
Outages Req'd
AU
D
50kVA 120/240v
Fault Current: 12,300
R/X: 0.6 %Z: 1.7
DESIGNED BY
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
REV#DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
10/22/25
M.Taylor 85-5970 10/22/25
M.Taylor 85-5970 10/22/25
REQ'D City of Yelm
Yelm Plaza LLC
Cmrcl - Upgrade OH Xfmr & Secondary Line Extension
904 Yelm Ave E Yelm, WA 98597
PSE
105108817
AS NOTED 01 of 01
THURSTON QSTHLE
??¼,Sect??,T??,R??
1702W060 1702W056 1702W058 YEL-26
J:\Electric_Southwest\THURSTON\John Singleton\3_COMMERCIAL\105108817_Yelm Plaza_904 E YELM AVE_514709338\5_CAD\105108817_YelmPlaza.dwg10
/
2
4
/
2
5
_
1
1
:
3
1
a
m
P
l
o
t
t
e
d
B
y
:
p
c
o
u
r
t
J:
\
e
l
e
c
t
r
i
c
_
s
o
u
t
h
w
e
s
t
\
t
h
u
r
s
t
o
n
\
j
o
h
n
s
i
n
g
l
e
t
o
n
\
3
_
c
o
m
m
e
r
c
i
a
l
\
1
0
5
1
0
8
8
1
7
_
y
e
l
m
p
l
a
z
a
_
9
0
4
e
y
e
l
m
a
v
e
_
5
1
4
7
0
9
3
3
8
\
5
_
c
a
d
\
1
0
5
1
0
8
8
1
7
_
y
e
l
m
p
l
a
z
a
.
d
w
g
HP Svc/MSA
HP Main
Distribution
Job Order
Temporary
Removal
Perm Svc
OH Xfmr Repl.
Superior
ORDER#NOTIF#
PWR
PROJECT PHASE
N/AN/A
N/AN/A
N/AN/A
N/AN/A
N/AN/A
N/AN/A
104372853516657554
583081973
105108817514709338
CABLE TV
PHONE
GAS
CUSTOMER NOTE:
SITE MUST BE READY 1-WEEK
PRIOR TO CONSTRUCTION DATE
SITE SPECIFIC NOTES
AT P01 GRID # 559222-147676 45' CL2 (1973)
REPL EXIST 37.5kVA OH XFMR W/ 50kVA OH XFMR 120/240v - Std 6025.1000 (TRFRXF) 3-11
REPL EXIST FUSE W/ 15T
AT P02 GRID # 559212-147681 30' CL2 (1991) ** NOT MAPPED
INST 3" SEC RISER ON S/O BRKTs (ACTUAL=____') - Std 6042.1000 (RIS3CSS)
AT HH1
INST 17”x 30” SEC HH W/#10-350 (6) POS CONN BARS - Std 6050.2000 (HH16350) 3-22
CONNECT & TAG CUSTOMER RAN UG SVC LINES (5) RUNS OF 1/0
AT M01-M05
PERM METERS
P02 TO HH1:
INST 350MCM UG TPLX SVC ±50' IN CUST PROVIDED TRENCH & 3" SCH40 CONDUIT (TOTAL
BILLABLE LGTH ±10')
POWER GENERAL NOTES - COMMERCIAL PROJECT
1.All materials to be installed in accordance with Puget Sound Energy's (PSE) standards. Any deviation from
this work sketch must be AUTHORIZED by PSE's Project Manager and NOTED on the Foremans' Copy.
2.All switching arrangements and/or outage arrangements are to be made with the Project Manager at least
three (3) working days in advance.
3.Contact the Utilities Underground Location Center (1-800-424-5555) at least 48 hours prior to commencing
work to get the underground facilities located.
4.STAKING: The customer will provide all staking (transformer, handhole, trench, grade, lot, pole, sidewalk,
etc.). See sketch and details for locations. Equipment locations must be approved by the Project Manager.
5.SITE PREPARATION: The work area will be at or near finished grade, clear of trench spoils or construction
materials which would restrict construction and/or equipment access, before work can begin.
6.Roads shall be paved or have a compacted , crushed rock base in place.
7.CLEARANCES: Transformers require a minimum of 6 feet from fire fighting equipment, 10 feet from
combustible walls, overhangs, doors, and windows, and a minimum of 5 feet from the back of curb (or guard
posts will be required per PSE standards). All conduits and vaults are to be at least 5 feet away from water,
storm and sewer lines when paralleling them in the right of way, and at least 1 foot when crossing them.
8.All work is to be done in accordance with local municipal and county permit requirements as applicable.
9.Customer/Developer is responsible to provide, install and maintain all secondary service cables, conduits
and crossings from the individual unit's meter base to the designated connection point.
10.Inclement weather conditions may cause delays in construction times and dates.
11.EXCAVATION: The customer is to provide all trenching, backfill, vault excavations, compaction and
restoration per this sketch and per PSE standards. A minimum protective cover of 36" is required over PSE's
primary voltage equipment and 24" is required of PSE's secondary voltage equipment. The customer will
provide any and all shoring or they will side slope the trench to 1:1.
J.Singleton (360) 522-3156
John.Singleton@pse.com
(360) 522-3156
John Singleton
E-Mail:
Cell Phone:
Project Manager Contact Information:
Manager:
559212-147681
** Not Mapped
** Service
Previously
Removed
559222-147676
37.5kVA AØ
50kVA 120/240v AØ
±27"
2"
18"
Captive L-Bolt
Lock Cover, 10 lbs
±40"
±30"
±17"
SINGLE PHASE SECONDARY HANDHOLE
Not to scale 6050.2000
SIDE VIEW
TOP VIEW
5'-6"
4'-5"
Cust service conductors
Conductors enter
from beneath and
shall be folded back
with handhole
Captive L-Bolt Lock Cover
Set handhole flush
to final grade
20"
TOP VIEW
5" Min
CL
LC
Direction of Vehicular Traffic
CONDUIT RISER PLACEMENT DETAIL (P02)
SCALE: NONE
Field Face
Quadrant
Climbing
Space
Road Face
Quadrant
Climbing
Space