HomeMy WebLinkAbout25.11.10 Pulse Yelm TI - Permit Set@ AT
A.B.ANCHOR BOLT
AC. / ACOUST.ACOUSTICAL
A.C.T.ACOUSTICAL CEILING TILE
A.D.A.AMERICANS WITH DISABILITIES
ACT
ADJ.ADJUSTABLE / ADJACENT
AFF. / A.F.F.ABOVE FINISH FLOOR
ALT.ALTERNATE
ALUM.ALUMINUM
ANOD.ANODIZED
APPROX.APPROXIMATE
BD.BOARD
BLDG.BUILDING
BLKG.BLOCKING
BM.BEAM
BNDRY.BOUNDARY
B.O.BOTTOM OF
BOT.BOTTOM
BTW.BETWEEN
CAB.CABINET
C.B.CATCH BASIN
C.L.CENTER LINE
CLG.CEILING
CLKG.CAULKING
CLR.CLEAR
C.M.U.CONCRETE MASONRY UNIT
C.O.CENTER OF
COL.COLUMN
CONC.CONCRETE
CONST.CONSTRUCTION
CONT.CONTINUOUS
CONTR.CONTRACTOR
CORR.CORRIDOR
CPT.CARPET
CSR CUSTOMER SERVICE
REPRESENTATIVE
C.T.CERAMIC TILE
CTR.CENTER
DBL.DOUBLE
DEMO.DEMOLISH / DEMOLITION
DET.DETAIL
DIA.DIAMETER
DIM.DIMENSION
DISP.DISPENSER / DISPOSAL
DR.DOOR
DRY.DRYER
DS.DOWNSPOUT
D/W DISHWASHER
DWG.DRAWING
E.EAST
EA.EACH
ELEC.ELECTRICAL
ELEV.ELEVATION / ELEVATOR
EMER.EMERGENCY
ENCL.ENCLOSURE
ENG.ENGINEERED
ETC.ETCETERA
EQ.EQUAL
EQUIP.EQUIPMENT
EX. / EXIST.EXISTING
EXT.EXTERIOR
F.A.FIRE ALARM
F.D.FLOOR DRAIN
FND.FOUNDATION
F.E. / F.X.FIRE EXTINGUISHER
F.F.E.FINISH FLOOR ELEVATION
FIN.FINISH
FLR.FLOOR
FLUOR.FLUORESCENT
F.O.FACE OF
F.O.C.FACE OF COLUMN
F.O.F.FACE OF FINISH
F.O.S.FACE OF STUD
FRMG.FRAMING
FT.FOOT / FEET
FTG.FOOTING
FURN.FURNITURE
FURR.FURRING
GA.GAUGE
GAL.GALLON
GALV.GALVANIZED
G.B.GRAB BAR
G.C.GENERAL CONTRACTOR
G.L.GLUE LAMINATED
GLZ'G.GLAZING
GLS.GLASS
GR.GRADE
G.W.B.GYPSUM WALL BOARD
GYP.GYPSUM
H.B.HOSE BIBB
H/C HANDICAPPED
H.C.HOLLOW CORE
H.D.O.HIGH DENSITY OVERLAY
HDWD.HARDWOOD
HDWR.HARDWARE
H.M.HOLLOW METAL
HORIZ.HORIZONTAL
HR.HOUR
HSS.HOLLOW STRUCTURAL SECTIONS
HT.HEIGHT
HTR.HEATER
H.W.HOT WATER
IN.INCH
I.D.INSIDE DIAMETER
INSUL.INSULATION / INSULATED
INST.INSTALL / INSTALLED
INT.INTERIOR
JAN.JANITOR
J.B.JUNCTION BOX
LAM.LAMINATE / LAMINATED
LAV.LAVATORY
L.F.LINEAR FOOT / FEET
LIN.LINEAR
LT.LIGHT
MANUF./ MFR.MANUFACTURER
MAT'L.MATERIAL
MAX.MAXIMUM
MBR.MEMBER
MDF.MEDIUM DENSITY FIBERBOARD
M.D.O.MEDIUM DENSITY OVERLAY
MECH.MECHANICAL
MEMB.MEMBRANE
MIN.MINIMUM
MISC.MISCELLANEOUS
M.O.MASONRY OPENING
MTD. / MNTD.MOUNTED
MTL.METAL
MUL.MULLION
N.NORTH
N/A NOT APPLICABLE
N.I.C.NOT IN CONTRACT
NO.NUMBER
NOM.NOMINAL
N.T.S.NOT TO SCALE
O/OVER
O.A.OVERALL
O.C.ON CENTER
O.D.OUTSIDE DIAMETER
OFF.OFFICE
OPNG.OPENING
OPP.OPPOSITE
PART.PARTITION
PERP.PERPENDICULAR
P.L.PROPERTY LINE
P.LAM.PLASTIC LAMINATE
PLAS.PLASTIC
PLYWD.PLYWOOD
PPT.PARAPET
POLY.POLYETHYLENE
PR.PAIR
PRE-ENG.PRE-ENGINEERED
PROP.PROPOSED
PT.PAINT
P.T.PRESSURE TREATED
P.T.D.PAPER TOWEL DISPENSER
PTL.PARTIAL
RAD.RADIUS
R.C.P.REFLECTED CEILING PLAN
R.D.ROOF DRAIN
REF. / REFRIG.REFRIGERATOR
REFL.REFLECTED
REINF.REINFORCE / REINFORCED
REQ.REQUEST
REQS.REQUIREMENTS
RESIL.RESILIENT
RF.ROOF
RM.ROOM
R.O.ROUGH OPENING
S.SOUTH
S.C.SOLID CORE
S.C.D.SEAT COVER DISPENSER
SCHED.SCHEDULE
S.D.SOAP DISPENSER
SEP.SEPARATION
S.F.SQUARE FOOT / FEET
SH.SHOP PRIMED AND PAINTED
SHTG.SHEATHING
SIM.SIMILAR
SIMP.SIMPSON
SGL.SINGLE
S.N.D.SANITARY NAPKIN DISPENSER
SPEC.SPECIFICATION
SQ.SQUARE
S.ST.STAINLESS STEEL
ST.STAIN
STA.STATION
STD.STANDARD
STL.STEEL
STRL.STRUCTURAL
STRUCT.STRUCTURE / STRUCTURAL
SUSP.SUSPENDED
S.V.SHEET VINYL
SYM.SYMMETRICAL
SYMB.SYMBOL
SYST.SYSTEM
T.B.TOWEL BAR
T.B.D.TO BE DETERMINED
T&G TONGUE AND GROOVE
TEL.TELEPHONE
TER.TERRAZZO
THK.THICK
T.I.TENANT IMPROVEMENT
T.O.TOP OF
T.P.TOILET PAPER
TRTD.TREATED
T.S.TUBE STEEL
TYP.TYPICAL
U.N.O.UNLESS NOTED OTHERWISE
V.C.T.VINYL COMPOSITION TILE
VERT.VERTICAL
V.T.R.VENT THROUGH ROOF
W.WEST
W/WITH
W.C.WATER CLOSET
WD.WOOD
W.H.WATER HEATER
WIN.WINDOW
W/O WITHOUT
WSH.WASH
WT.WEIGHT
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
A1.1
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
CABREIVIATIONS
PROJECT DATA
PROJECT DESCRIPTION
THE SCOPE OF WORK SHALL BE THE INITIAL IMPROVEMENT OF AN EXISTING VACANT
SHELL SPACE FOR AN OUTPATIENT MEDICAL CLINIC.
THE WORK SHALL INCLUDE NEW TENANT WALLS, CABINETRY, PLUMBING & ELECTRICAL.
HVAC, FIRE SPRINKLERS & FIRE ALARM SYSTEMS WILL BE MODIFIED.
THE CONTRACTOR SHALL INCLUDE ANY AND ALL TRADES TO BRING THE PROJECT TO USE
BY THE TENANT PER THE PLANS AND DOCUMENTS AS PROVIDED AND APPROVED BY
ZENCZAK & PARTNERS ARCHITECTS. MODIFY EXISTING FIRE SPRINKLER SYSTEM PER FIRE
SPRINKLER SUBCONTRACTOR (CONFIRM IF WORK IS REQUIRED).
PROJECT TEAM
OWNER: YELM PLAZA LLC
18230 E VALLEY HWY, STE 195
KENT, WA 98032
TENANT: CARDIAC STUDY CENTER "DBA" PULSE HEART INSTITUTE
ARCHITECT: ZENCZAK & PARTNERS, ARCHITECTS AIA
3720 6TH AVENUE, SUITE A
TACOMA, WA 98406
(253) 475-0380
studio@zpaaia.com
CONTACTS: BZ ZENCZAK & RICK ADAMS
CONTRACTOR: RUSH COMMERICAL
6622 WOLLOCHET DRIVE
GIG HARBOR, WA 98335
(253) 858-3636
bgriffin@therushcompanies.com
CONTACT: BRET GRIFFIN (253) 432-7028
VICINITY MAP
NORTH
904 E. YELM AVE., SUITE A
YELM , WA
KEY PLAN
PROJECT
LOCATION
PROJECT DESCRIPTION: PULSE HEART INTITUTE
902 E YELM HWY, STE A
YELM, WA 98597
TAX PARCEL NUMBER: 22730110203
T.I. PROJECT AREA: 2,200 SF
BUILDING CODE:2021 INTERNATIONAL BUILDING CODE (& I.E.B.C.)
AS AMENDED BY THE CITY OF YELM
TYPE OF CONSTRUCTION: TYPE V-B (SPRINKLERED)
OCCUPANT TYPE:B
OCCUPANT LOAD:25 (SEE SHEET A2.1 FOR OCCUPANT LOAD CALC.)
BIDDER DESIGN ITEMS: HVAC, PLUMBING, FIRE SPRINKLERS, FIRE ALARM &
ELECTRICAL.
DEFERRED SUBMITTALS: HVAC, FIRE SPRINKLERS, FIRE ALARM & ELECTRICAL.
ANY DISCREPANCIES FOUND AMONG THE DRAWINGS, THE GENERAL NOTES AND THE SITE
CONDITIONS SHALL BE REPORTED TO THE ARCHITECT WHO SHALL CORRECT SUCH
ERROR OR OMISSION IN WRITING. ANY WORK DONE BY THE CONTRACTOR AFTER
DISCOVERY OF SUCH ERROR SHALL BE DONE AT THE CONTRACTOR'S RISK. THE
CONTRACTOR SHALL VERIFY AND COORDINATE ALL DIMENSIONS FOUND AMONG ALL
DRAWINGS PRIOR TO PROCEEDING WITH ANY WORK OR FABRICATION. THE CONTRACTOR
IS RESPONSIBLE FOR ALL BRACING AND SHORING DURING CONSTRUCTION.
225-3590
11/10/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/10/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
SHEET INDEX
SHT # SHEET DESCRIPTION
A1.1 COVER SHEET
A2.1 OCCUPANCY & EXIT PLAN
A2.2 DEMOLITION PLAN
A2.3 FLOOR PLAN
A3.1 DOOR SCHEDULE
A4.1 INTERIOR ELEVATIONS
A4.2 INTERIOR ELEVATIONS
A4.3 INTERIOR ELEVATIONS
A5.1 ARCHITECTURAL DETAILS
A6.1 ARCHITECTURAL SPECIFICATIONS
P1.1 PLUMBING PLANS & RISER DIAGRAM
E1.1 POWER & DATA PLAN
E2.1 LIGHTING & REFLECTED CEILING PLAN
PLAN NORTH
AREA OF WORK
SYMBOLS LEGEND
ELEVATION
REFERENCE
DRAWING
REVISION
REFERENCE
ROOM NAME
AND NUMBER
DOOR TYPE - SEE
DOOR SCHEDULE
#
A#.#
#
ROOM NAME
RM#
#
FINISH PAINT
REVERENCE
P#
P#
P#
P#
EXAM #11 OCC
103 EXAM #21 OCC
104
EXAM #41 OCC
111
EXAM #81 OCC
114EXAM #71 OCC
115EXAM #61 OCC
116
EXAM #31 OCC
109
TOILET #21 OCC *
106TOILET #11 OCC *
105
BREAK ROOM1 OCC *
108
PROVIDERS1 OCC
113
I.T.1 OCC *
118
WAITING ROOM12 OCC
101
RECEPTION1 OCC
102
ECHO1 OCC
119
LEADER1 OCC
112
M.A.1 OCC
110
JAN.1 OCC *
107
HOTEL1 OCC *
117
FE
37'-0"
12
'
-
5
"
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
OCCUPANCY & EXIT PLAN 00 4 8
NORTH
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
225-3590
11/10/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/10/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
A2.1
PE
R
M
I
T
S
E
T
GROSS OCCUPANT CALCULATION:
2,220 SF 150 = 14.8 OCCUPANTS
+36+36
EXISTING ELECTRICAL
PANEL TO REMAIN
REMOVE EXISTING
STUDWALLS SHOWN
DASHED, TYP.
EXISTING PLUMBING
ROUGH-IN FOR W.C.
MODIFY AS NEEDED FOR
NEW W.C. LOCATION
EXISTING PLUMBING
ROUGH-IN FOR W.C.
MODIFY AS NEEDED FOR
NEW W.C. LOCATION
REMOVE EX. ELECTRICAL
OUTLETS AND ALL RELATED
WIRING BACK TO ELECTRICAL
PANEL.
±9'-6" VERIFY
±5'-0" VERIFY±13'-8" VERIFY
1'
-
4
7
8"
EXISTING INTERIOR
DEMISING WALL w/
G.W.B. TAPED.
EXISTING EXTERIOR
WALL w/ G.W.B. TAPED.
EX. ALUM. STOREFRONT DOOR.
SEE DOOR SCHEDULE FOR
HARDWARE MODIFICATIONS.
EX. ALUM. FRAME
WINDOW TO REMAIN
EXISTING EXPOSED
PLUMBING PIP IN SLAB
TO BE ENCLOSED PER
NEW FLOOR PLAN.
PROPOSED LOCATION OF
SAW-CUT FOR NEW PLUMBING
WASTE LINE. VERIFY FINAL
LOCATION PER BIDDER DESIGN
PLUMBING SUBCONTRACTOR.
EX. ALUM. FRAME
WINDOW TO REMAIN
EX. ALUM. FRAME
WINDOW TO REMAIN
EX. ALUM. FRAME
WINDOW TO REMAIN
CREATE OPENING IN
EXISTING EXTERIOR WALL
FOR NEW EXTERIOR DOOR.
VERIFY LOCATION OF EX.
ELECTRICAL GEAR ON
EXTERIOR WALL
4'
-
8
"
3'
-
4
"
REMOVE EXISTING DOOR
HARDWARE AND LOCK
DOOR IN PLACE.
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
DEMOLITION PLAN 00 4 8
NORTH
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
225-3590
11/10/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/10/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
A2.2
PE
R
M
I
T
S
E
T
EXAM #1103 EXAM #2104
EXAM #4111
EXAM #8114EXAM #7115EXAM #6116
EXAM #3109
TOILET #2106TOILET #1105
BREAK ROOM108
PROVIDERS113
I.T.118
WAITING ROOM101
RECEPTION102
SC
A
L
E
ECHO119
LEADER112
M.A.110
±7'-33 8"10'-512"8'-10"10'-512"4'-114"7'-618"9'-914"
4'-73 4"
3'-0"
7"
7'-21 4"6'-1114"10'-43 4"10'-17 8"2'-818"±7'-612"7'-23 4"2'-23 4"
8'
-
1
3
8"
4'
-
1
14"
8'
-
5
"
4'
-
1
14"
8'
-
2
18"
8'
-
6
5
8"
7'
-
1
0
12"
12
'
-
0
"
10'-414"5'-33 4"10'-113 8"10'-17 8"10'-23 8"±12'-03 8"
6'-47 8"
2'-4"
9'-1014"10'-17 8"10'-6"
3'
-
1
0
14"
4'
-
3
7
8"
12
'
-
8
5
8"
6'
-
5
1
4"
6'
-
7
3
8"
7'
-
1
3
4"
1'
-
0
"
6'
-
1
3
4"
2'-5"4'-0"2'-5"
RCRCRCRC
B
B
B
B
B
B
B
CD
EE
E
E
EE
2'-5"4'-0"2'-5"
GFFFFF
F
F
F
G
G
G
±4
'
-
5
7
8"
JAN.107
HOTEL117
1
2
4
5 6 7 8
9
10
11 12
3
13
14151617
18
19
SINK DW
MOP
SINK
DOOR
OPENER
DOOR OPENER
DOOROPENERCONTROLS
8A5.1 8A5.1 8A5.1
8A5.1
SIM
G
SIM
G
SIM
R9'-3"
8"
42" HIGH
COUNTER
30" HIGH
COUNTER
FE
WH
SINK
EXISTING STUD WALL & G.W.B. TO REMAIN.PATCH & PAINT AREAS AS NEEDED WHENEFFECTED BY NEW WORK, TYP. U.O.N.
WALL LEGEND
#DOOR PER SCHEDULE - SEE SHEET A3.1
A
NEW 35 8" MTL. STUD WALL PER DETAIL 1A5.1
NOTE:ALL DIMENSIONS ARE FACE OF STUD UNLESS NOTED OTHERWISE.
FE
NEW SEMI-RECESSED FIRE EXTINGUISHER
NEW 6" MTL. STUD WALL PER DETAIL
C
1A5.1
B
NEW 35 8" MTL. STUD WALL W/ 12"RESILIENT CHANNEL, PER DETAIL
EXISTING STUD WALL & G.W.B. w/ NEWRESILIENT CHANEL & NEW G.W.B. PER
RC
TYP. IF NOTNOTED
4A5.1
2A5.1
SIM.
E
NEW 35 8" MTL. STUD HALF-HT WALLPER DETAIL 3A5.1
NEW 6" MTL. STUD WALL w/RESILIENT CHANNEL PER DETAIL
D
2A5.1 SIM.
NEW WALL FURRING @ EXISTINGEXTERIOR WALL PER DETAIL 5A5.1
F
NEW PARTIAL HEIGHT WALL FURRING:w/ WOOD CHAIR RAIL @ TYP. DETAILUNDER NEW COUNTERTOP @ SIM 6A5.1GG
SIM
P1
P1
P1
P1
C1
B1
EXAM #1103 EXAM #2104
EXAM #4111
EXAM #8114EXAM #7115EXAM #6116
EXAM #3109
TOILET #2106TOILET #1105
BREAK ROOM108
PROVIDERS113
ELEC
PANEL
I.T.118
HO
T
E
L
WAITING ROOM101
RECEPTION102 PR
I
N
T
E
R
S
ST
O
R
A
G
E
CH
E
C
K
-
I
N
CHECK-OUT
SC
A
L
E
PR
I
N
T
E
R
S
ST
O
R
A
G
E
PR
I
N
T
E
R
S
ST
O
R
A
G
E
ECHO119
PRINTERS
STORAGE
LEADER112
M.A.110
PRINTERS
STORAGE
CG
CG
CG
CG
CG
CG CG
CG
CG
CG
3'
-
0
"
3'
-
0
"
5'
-
3
"
4'-3"
1'
-
9
"
1'
-
2
"
2'
-
0
"
VE
R
I
F
Y
1'
-
6
"
MI
N
.
CL
R
.
4'-6"
3'
-
8
"
3'
-
8
"
4'-6"
1'
-
6
"
1'
-
6
"
1'
-
6
"
1'
-
6
"
1'
-
3
"
JAN.107
HOTEL117
1'-9"
5'
-
0
"
1'-9"
1
2
4
5 6 7 8
9
10
11 12
3
13
14151617
18
19
SINK DW
WCWC
LAV LAV
MOP
SINK
DOOR
OPENER
DOOR OPENER
DOOROPENERCONTROLS
TO
P
O
F
F
U
R
R
I
N
G
UN
D
E
R
C
O
U
N
T
E
R
.
TO
P
O
F
F
U
R
R
I
N
G
UN
D
E
R
C
O
U
N
T
E
R
.
TO
P
O
F
F
U
R
R
I
N
G
UN
D
E
R
C
O
U
N
T
E
R
.
PR
O
V
I
D
E
W
D
.
C
A
P
BE
T
W
E
E
N
C
O
U
N
T
E
R
S
TO
P
O
F
F
U
R
R
I
N
G
UN
D
E
R
C
O
U
N
T
E
R
.
PR
O
V
I
D
E
W
D
.
C
A
P
BE
Y
O
N
D
C
O
U
N
T
E
R
TO
P
O
F
C
A
P
+2
'
-
1
0
"
1A4.1
2A4.1
3A4.1
4A4.1
6A4.1
6A4.1
6A4.1
6A4.1
6A4.16A4.16A4.1
7A4.1
8A4.2 9A4.2
11A4.2
10A4.2
12A4.2
13A4.2
14A4.2
15A4.2
42" HIGH
COUNTER
30" HIGH
COUNTER
CGFE
F2
P4
P3/2
P2
P1
C1
B1
F1
-
P2
-
P2
C1
B1
F1
P1
P3
P1/3
P1
C1
B1
F1
P3
P1/3
P1
P1
C1 B1 F1
P4
P1
P1
P1
C1
B1
F3
P4
P1
P1
P1
C1
B1
F3
P1
P1
P4
P1
C1
B1
F3
P1
P1
P4
P1
C1
B1
F3
P1
P1
P4
P1
C1
B1
F3
P1
P1
P4
P1
C1
B1
F3
P1
P1
P4
P1
C1
B1
F3
P1
P4
P1
P1
C1
B1
F3
P1
P2
P1
P1
C1
B1
F2
P1
P1
P2
P1
C1
B1
F2
P1
-
P2
-
C1
B1
F2
P2
-
P1
-
C1
B1
F2
P1
P1
P1
P1
C2
B2
F4
TYP. IN TOILET ROOMS
P1
P1
P1
P1
C2
B2
F4
IN JAN. CLOSET
IN I.T. ROOM
P1/2
P1
P2
P2
C1
B1
F1
IN RECEPTION
CG
CG
WH
1'-9"
SINK
2'-0"
1'-9"
1'-9"
FLOOR FINISH PER MATERIALS KEY
ADDITIONAL INFO IN SPECIFICATIONS
WALL BASE PER MATERIALS KEY
ADDITIONAL INFO IN SPECIFICATIONS
PAINT CALLOUTS PER COLOR SPECIFICATIONS LISTED
BELOW NOTE: ALL WALLS SHALL RECEIVE EGGSHELL
FINISH UNLESS NOTED OTHERWISE
FLOORING:
SEE HATCHING ON PLAN @ FLOORING TRANSITIONS
F1 - CARPET TILE MOHAWK: COLLECTION-EXPEDITION,
PATTERN-LITHOSPHERE
COLOR- 739 GLACIER (BRICK ASHLAR INSTALL)
F2 - LV TILE TEKNOFLOR: STYLE "RARE PLANK HPD",
COLOR 89007RP "SISAL: (7" x 47" PLANKS)
(IN ALL HALLWAYS TYP.)
F3 - SHEET VINYL TEKNOFLOR: STYLE "FORESTSCAPES HPD"
COLOR 88063 DAWN (6'W x 75'L ROLLS)
(IN EXAM ROOMS, TYP.)
F4 - SHEET VINYL MANNINGTON: COLLETION-PARADIGM II,
STYLE-STREAMLINE COLOR: PD211 "FOUNDATION" (6',
9', 12' W ROLLS)
CEILING FINISH PER MATERIALS KEY
ADDITIONAL INFO IN SPECIFICATIONS
PAINT COLORS:
P1 - COMMON RODDA MIX# 19-05-909 TO MATCH BARRISTER
WHITE. DEFAULT COLOR ON WALLS UNLESS
OTHERWISE NOTED.
P2 - LIGHT TAN RODDA #0230 "FROND" DEFAULT COLOR ON
SOFFITS UNLESS OTHERWISE NOTED.
P3 - LIGHT BROWN RODDA #0233 "DEEP MARSH
P4 - ACCENT RED RODDA #0094 "STARLET
FLOOR BASE:
B1 -RUBBER BASE ROPPE COLOR 193 "BLACK BROWN"
B2 -COVED BASE 4" INTEGRAL SHEET VINYL COVED BASE
CEILINGS:
C1 - SUSP. AC. TILE ARMSTRONG "CORTEGA SECOND LOOK II"
C2 - GYP. WALL BD.5 8" G.W.B. TAPED AND TEXTURED
FINISH SYMBOL PER ROOM AS FOLLOWS:
PLASTIC LAMINATE FOR CASEWORK:
PL1 - FOR ALL CABINET VERTICAL SURFACES
WILSONART "SLATE GREY" D91-60 MATTE FINISH
PL2 - FOR ALL COUNTER TOPS AND BACK SPLASHES
WILSONART "CRISP LINEN" 4942-38 FINE VELVET FINISH
PL3 - FOR ALL TOILET ROOM WAINSCOTS
WILSONART "CASUAL LINEN" 4944-38 FINE VELVET FINISH
FINISH LEGEND
CORNER GUARD:PROVIDE 48" MINIMUM CLEAR CORNER GUARD MOUNTEDWITHIN 12" OF FINISH FLOOR
CG
P#
P#
P#
P#
C#
B#
F#
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
FLOOR PLAN 00 4 8
NORTH
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
225-3590
11/10/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/10/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
A2.3
PE
R
M
I
T
S
E
T
FIXTURE & FINISH PLAN 00 4 8
NORTH
TYPE A
EXISTING EXT.
ALUMINUM
STOREFRONT
ENTRY DOOR
TYPE D
NEW INT. WOOD
DOOR IN HOLLOW
METAL FRAME.
TYPE D
NEW EXT.HOLLOW
METAL DOOR &
FRAME.
TYPE B
EXISTING EXT.
HOLLOW METAL
DOOR & FRAME.
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
A3.1
DOOR SCHEDULE
FOR NEW DOOR LOCATIONS
KEY SIZE
NEW
RM#NEW LOCATION TYPE
DOOR
FIN
FRAME
FIN
HARD-
WARE NOTES:
1 EXISTING
3'-0" x 7'-0"101 WAITING ROOM A AS AS 1 ADD NEW AUTOMATIC DOOR OPENER TO EXISTING
DOOR & FRAME. SEE FLOOR PLAN FOR DOOR
SWITCH LOCATIONS.
2 EXISTING
3'-0" x 7'-0" x 13 4"107 JANITOR'S CLOSET B PT PT -
DOOR TO BE ABANDONED. REMOVE EXISTING
LEVER HARDWARE.HARDWARE PROVIDE
DEADBOLT WITH THUMB-TURN ON INT. SIDE ONLY.
3 3'-0" x 7'-0" x 13 4"108 BREAK ROOM C PT PT 2 NEW EXTERIOR DOOR. VERIFY LOCATION OF
EXISTING ELECTRICAL FOR FINAL DOOR LOCATION.
4 3'-0" x 7'-0" x 13 4"101 WAITING ROOM D ST PT 4
5 3'-0" x 7'-0" x 13 4"103 EXAM ROOM #1 D ST PT 5
6 3'-0" x 7'-0" x 13 4"104 EXAM ROOM #2 D ST PT 5
7 3'-0" x 7'-0" x 13 4"105 TOILET ROOM #1 D ST PT 3 PRIVACY LOCK TO HAVE "VACANT/OCCUPIED"
INDICATOR ON HALLWAY SIDE.
8 3'-0" x 7'-0" x 13 4"106 TOILET ROOM #2 D ST PT 3 PRIVACY LOCK TO HAVE "VACANT/OCCUPIED"
INDICATOR ON HALLWAY SIDE.
9 3'-0" x 7'-0" x 13 4"107 JANITOR'S CLOSET D ST PT 5
10 3'-0" x 7'-0" x 13 4"108 BREAK ROOM D ST PT 4
11 3'-0" x 7'-0" x 13 4"109 EXAM ROOM #3 D ST PT 5
12 3'-0" x 7'-0" x 13 4"111 EXAM ROOM #4 D ST PT 5
13 3'-0" x 7'-0" x 13 4"112 LEADER D ST PT 5
14 3'-0" x 7'-0" x 13 4"113 PROVIDERS D ST PT 5
15 3'-0" x 7'-0" x 13 4"114 EXAM ROOM #5 D ST PT 5
16 3'-0" x 7'-0" x 13 4"115 EXAM ROOM #6 D ST PT 5
17 3'-0" x 7'-0" x 13 4"116 EXAM ROOM #7 D ST PT 5
18 3'-0" x 7'-0" x 13 4"118 I.T. CLOSET D ST PT 6
19 3'-0" x 7'-0" x 13 4"119 ECHO D ST PT 5
DOOR TYPES
1. LEVER w/ LOCK , CLOSER & AUTOMATIC OPENER.
2. LEVER w/ LOCK & CLOSER.
3. LEVER w/ PRIVACY LOCK & CLOSER.
4. LEVER w/ PASSAGE HARDWARE & CLOSER.
5. LEVER w/ PASSAGE HARDWARE NO CLOSER.
6. LEVER w/ CIPHER LOCK - NO CLOSER.
FINISH KEY
AS ALUMINUM STOREFRONT
ST STAINED (WOOD)
PT PAINTED (SHOP PRIMED METAL)
HARDWARE GROUPS
225-3590
11/4/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/4/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
EQ.EQ.
6'-0"
2'
-
6
"
1'
-
0
"
1'-2"1'-2"8"1'-2"
14" REVEAL (BLACK),
TYP. ON THIS FACE.
101 - WAITING ROOM1
NORTH
PL. LAM.
COUERTOPS
G.W.B. o/ RESILIENT
CHANNEL.
4" RUBBER BASE
EAST
8"1'-2"
BLACK METAL EDGE
@ TRANSITION FROM
P.LAM TO G.W.B.
UPPER COUNTERTOP
BEYOND
LOWER COUNTERTOP
BEYOND
WEST
PARTIAL HT. WALL
PER DETAIL
HALF-WALL IN
FOREGROUND,
SHOWN DASHED
SOUTH
DOOR & FRAME
DOOR & FRAME
(ADD AUTOMATIC OPENER)
4" RUBBER BASE
NEW FURRING @
G.W.B. o/ EX. WALL
EDGE OF G.W.B. SOFFIT
ABOVE PER REFLECTED
CEILING PLAN.
3'
-
6
"
7A5.1
8A5.1
SOUTH
102 RECEPTION2
NORTH
2'-0"
2'
-
6
"
2'
-
0
"
2'
-
6
"
1'-0"
7'-0"
1'-4"
COUNTER &
BACK SPLASH
2"
1"1'-6"
2'-35 16"2'-35 16"2'-35 16"
1'-4"1'-4"1"1'-4"
4"
112"
6"
1'
-
6
12"3'
-
0
"
AUTOMATIC DOOR
OPENER BUTTON
2'-0"
PULSE LOGO SIGN.
COORDINATE INSTALLATION
w/ OWNER'S SIGN VENDOR
±4'-6"
±1
'
-
8
"
5'
-
0
"
EQ.EQ.
101-WAITING 102-RECEPTION
WEST
6"1'-2"6"
14" REVEAL (BLACK),
TYP. ON THIS FACE.
1'-3"1'-3"
9"
814"1'-4"814"1'-4"
SOUTH FROM HALL
102 RECEPTION CHECK-OUT3
LOCKING
CABINET
1'-3"1"2'-9"
2'
-
6
"
UPPER COUNTER BEYOND
LOWER COUNTER
1'-9"±3'-0" VERIFY
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
PL.LAM COUNTER
& SPLASH
G.W.B. SOFFIT PER
REFLECTED CEILING PLAN
NEW RESILIENT CHANNEL
AND G.W.B o/ EX. WALL
LOWER COUNTER
OVERHANG
VARIES PER PLAN
14" REVEAL (BLACK),
TYP. ON THIS FACE.
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
EAST
4'
-
0
"
TOP OF HANDLE OF FIRE
EXTINGUISHER CABINET
1'-10"
PARTIAL HEIGHT METAL
STUD w/ G.W.B. o/ EA. SIDE
P. LAM FINISH ON THIS SIDE2'
-
6
"
2'
-
0
"
2'
-
6
"
6"
6"
1'
-
0
12"
1'-9"2'-8"
3'
-
0
"
1'
-
6
"
4"
112"
2'-4"
2'-5"
2'
-
6
"
2'-3"
1"
1"2'-3"
612"
2'
-
0
"
2'
-
6
"
DESK
COUNTER
1"
2'-0"
1'-10"1"
1'
-
0
"
1'
-
6
"
2'
-
6
"
3'
-
0
"
1'
-
6
"
2'
-
6
"
1'-0"
4"
RUBBER
BASE
3'
-
8
"
HAND
SANITIZER,
TYP. IN EA.
EXAM ROOM
3"
8" x 8"
OPENING
FOR TRASH
2"
HALL PRINTER CABINET5
3'
-
0
"
1'
-
9
"
4"
112"
2'
-
3
"
5'-0"
612"
2'
-
0
"
EAST
1'-9"
3'
-
0
"
1'
-
9
"
2'
-
3
"
1'-6"2'-0"
1'-0"
SIDE ELEVATION
COUNTER &
BACK SPLASH
8" x 8"
OPENING
FOR TRASH
2"
2'-6"2'-6"
1'-6"
TYPICAL EXAM ROOM6
TYPICAL FRONT TYPICAL SIDE
FOR ROOMS: 103, 104, 109, 111, 114, 115 & 116
3'
-
0
"
1'
-
6
"
4"
112"
4'-0"
3'-7"
2'
-
6
"
1'-112"
1"
3'-6"
612"
2'
-
0
"
2'
-
6
"
DESK
COUNTER
1"
2'-0"
1'-10"
1'
-
0
"
1'
-
6
"
2'
-
6
"
3'
-
0
"
1'
-
6
"
2'
-
6
"
1'-0"
4" RUBBER
BASE
3'
-
8
"
HAND
SANITIZER,
TYP. IN EA.
EXAM ROOM
3"
8" x 8"
OPENING
FOR TRASH
2"
119 - ECHO ROOM7
EAST NORTH
1'-6" CLR.
MIN.
1"
1'-112"1'-112"
2'-3"1'-2"
7'
-
0
"
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
INTERIOR ELEVATIONS 00 2 4 A4.1
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
225-3590
11/4/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/4/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
NEW WD. SILL
@ EX. WINDOW
105 - TOILET #18
SOUTHNORTH
T.P. DISP.
4'
-
0
"
4'-6"
VERT. 114"Ø
GRAB BAR
HORIZ. 114"Ø
GRAB BAR
WATER RESISTANT
G.W.B., TYP. THIS ROOM
P.LAM. WAINSCOT
w/ MTL. EDGE
8"
3'
-
0
"
1'
-
6
"
4'
-
9
"
1'-6"
3'-6"
℄ OF W.C.
4" COVED BASE,
TYP. THIS ROOM
1'
-
6
"
M
A
X
.
TO
T
O
P
OF
S
E
A
T
WALL-HUNG
LAV. SINK
1'-3"
2'
-
5
"
2'
-
1
0
"
2'
-
8
"
3'
-
4
"
MIRROR IN
METAL FRAME
MAX. HT. OF
SINK RIM
MAX. HT. OF
BOT. EDGE OF
REFLECTIVE
SURFACE
6'
-
0
"
9"
11"
1'-618"
TYP. ALL LAVS:
MAINTAIN CLR. KNEE
SPACE AS INDICATED
BY HATCHED AREA
ALL PIPES SHALL BE
INSULATED TO
PROTECT CONTACT.
ALLOW NO EXPOSED
SHARP EDGES.
WEST
3'-4"
106 - TOILET #29
SOUTHNORTH
T.P. DISP.
4'
-
0
"
4'-6"
VERT. 114"Ø
GRAB BAR
HORIZ. 114"Ø
GRAB BAR
WATER RESISTANT
G.W.B., TYP. THIS ROOM
P.LAM. WAINSCOT
w/ MTL. EDGE
8"
3'
-
0
"
1'
-
6
"
4'
-
9
"
1'-6"
3'-6"
℄ OF W.C.
4" COVED BASE,
TYP. THIS ROOM
1'
-
6
"
M
A
X
.
TO
T
O
P
OF
S
E
A
T
WALL-HUNG
LAV. SINK
1'-3"
2'
-
5
"
2'
-
1
0
"
2'
-
8
"
3'
-
4
"
MIRROR IN
METAL FRAME
MAX. HT. OF
SINK RIM
MAX. HT. OF
BOT. EDGE OF
REFLECTIVE
SURFACE
6'
-
0
"
9"
11"
1'-618"
TYP. ALL LAVS:
MAINTAIN CLR. KNEE
SPACE AS INDICATED
BY HATCHED AREA
ALL PIPES SHALL BE
INSULATED TO
PROTECT CONTACT.
ALLOW NO EXPOSED
SHARP EDGES.
EAST
3'-4"
1'-9"1'-6"
4"
108 - BREAK ROOM11
NORTH
612"112"
1'
-
8
"
3'
-
0
"
3 4"
±2'-712"
1'-0"
7"
7"
8"
±2'-83 8"3 4"
6'
-
0
"
1'
-
6
"
2'-0"
1'
-
5
"
2'-4"
4'-412"
3 4"
OPEN SHELF FOR
MICROWAVE
REFRIG. w/
ICE MAKER18" DISH
WASHER
2'
-
1
0
"
EAST
2'-0"
2'
-
1
0
"
WEST
107 - JANITOR CLOSET10
NORTH EAST WESTSOUTH
3 4"
NEW DOOR & FRAME EX. DOOR & FRAME TO
BE LOCKED IN PLACE
6" COVED BASE,
TYP. THIS ROOM
FRP PANEL w/
METAL EDGE
FRP PANEL w/
METAL EDGE
MOP SINK
WATER HEATER
(PROVIDE SEISMIC
BRACING
PARTIAL HEIGHT FURRED
WALL w/ WD. CAP
EX. ELEC.
PANEL
NEW DOOR
& FRAME
4" RUBBER BASE
CONNECTION
FOR ICE-MAKER
1'-0"
1'-2"
EXTEND SHELF
FOR MICROWAVE
NEW DOOR
& FRAME
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
112 - LEADER12
NORTH
1"1"
2'
-
6
"
2'
-
0
"
4"
112"
2'
-
6
"
2'-6"
6"
1'
-
6
12"
1"
2'-6"
1"
1'-9"
2'
-
6
"
EAST SOUTH WEST
PARTIAL HEIGHT FURRED
WALL w/ WD. CAP
1'-0"
1'-9"3'-0"1'-3"
LOCKING
CABINET
NEW DOOR
& FRAME
2'
-
6
"
HALF-WALL UNDER
NEW COUNTER
WOOD CAP BEYOND
COUNTER
4" RUBBER
BASE
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
INTERIOR ELEVATIONS 00 2 4 A4.2
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
225-3590
11/4/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/4/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
1"
2'-6"
1"
113 - PROVIDERS13
NORTH EAST SOUTH WEST
PARTIAL HEIGHT FURRED
WALL w/ WD. CAPHALF-WALL UNDER
NEW COUNTER
WOOD CAP BEYOND
COUNTER
3'-3"1'-3"1'-3"1'-23 4"1'-23 4"3 4"3'-3"1'-3"3'-3"
2'
-
6
"
NEW DOOR
& FRAME
4" RUBBER
BASE 2'
-
6
"
2'
-
0
"
2'
-
6
"
7'
-
0
"
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
1'-9"1'-9"
LOCKING
CABINET
LOCKING
CABINET
LOCKING
CABINET
1'-9"1'-9"
1'-3"±2'-7"
LOCKING
CABINET
110 M.A. STAFF14
3'-9"
NORTH
3 4"3 4"
EAST SOUTH
1'-3"±2'-67 8"
LOCKING
CABINET
3 4"
WEST
1'-3"±2'-67 8"
LOCKING
CABINET
1'-3"1'-3"1'-3"
1'-3"1"1'-3"1'-3"1"
55 8"
3'
-
6
"
2'
-
6
"
2'
-
0
"
2'
-
6
"
2'
-
6
"
2'
-
0
"
2'
-
6
"
2'
-
0
"
2'
-
6
"
2'
-
0
"
2'
-
6
"
2'
-
0
"
3'
-
6
"
2'
-
6
"
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
2'
-
6
"
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
1'-9"
2'-5"
1'-9"
2'-5"
1'-9"
2'-5"
1'-9"
2'-5"
117 HOTEL15
NORTH @ DESK NORTH @ HALL
1'-3"±2'-714"
LOCKING
CABINET
3 4"
EAST
1'-3"1"1'-3"1'-3"1"
2'
-
6
"
2'
-
0
"
2'
-
6
"
2'
-
0
"
3'
-
6
"
2'
-
6
"
2'
-
0
"
2'
-
6
"
2'
-
0
"
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
P.LAM SOFFIT ABOVE, TYP
@ ALL UPPER CABINETS
1'-9"
1'-0"
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
INTERIOR ELEVATIONS 00 2 4 A4.3
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
225-3590
11/4/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/4/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
BEGIN 4'-0" FROMSTRUTS @ 12'-0" O.C.VERTICAL STRUT
CROSS TEE
CROSS TEEPARALLEL TO
WALLS MIN.
2" MAX
.
MAIN BEAM
MAX.45°CROSS TEEPARALLEL TO
MAIN BEAMPARALLEL TO
TYPICAL NEW WALL
1" = 1' - 0"1
.125" X2" LAG SCREWINTO STRUCTURE ABOVE
1" W X 2" L X12 GA.(MIN)STEEL STRAP
TURN 3 TIMES (MINIMUM)
SPLAYED SEISMIC BRACINGWIRE (TURN THREE TIMES MIN.)
45
.
0
0
°
.125" X2" LAG SCREWINTO STRUCTURE ABOVE
1" W X 2" L X12 GA.(MIN)STEEL STRAP
EXISTING STRUCTURE (ABOVE)
VERTICAL HANGER WIRE(TURN THREE TIMES MIN.)
CEILING STRUT
EXISTING STRUCTURE (ABOVE)
12 GA. WIRE, TYP.
MAIN BEAMPARALLEL TO
3"
M
A
X
.
HORIZONTAL GRID (PER DETAIL 5)
3" MAX.
3"
M
A
X
.
4
5
.
0
0
°
45
.
0
0
°
HORIZONTAL GRID (PER DETAIL 5)
8" M
A
X
.
WALL
2" M
I
N
.
34" MI
N
.
SPREADER BAR OR OTHER
SUITABLE SYSTEM
REQUIRED TO KEEP
PERIMETER COMPONENTS
FROM SPREADING APART
NTS9
CLG. WALL MOLDING
NTS10
CLG. VERTICAL HANGER
NTS12
CLG. ANGLED HANGER
NTS11
3" SOUND BATT.
INSUL.
5 8" GYP. WALL BD.
(1 LAYER EA. SIDE)
35 8" MTL. CHANNEL
FASTEN TO EX. FLR.
NEW BRACING TO
EXIST'G STRUCTURE ABOVE
@ 8'-0" O.C. MAX.
2'-0"
35 8" MTL. TOP CHANNEL
TO NEW BRACING
45
.
0
0
°
NEW SUSPENDED
ACOUSTIC CLG.
2'-0"
PROVIDE NEW 3" SOUND
BATT INSUL. AS SHOWN.
35 8"MTL. STUDS
@ 16" O.C.
SE
E
R
E
F
L
E
C
T
E
D
C
L
G
.
P
L
A
N
FO
R
C
L
G
H
T
.
C
A
L
L
O
U
T
6"
MI
N
.
NEW WALL w/ RESILIENT. CHNL.
1" = 1' - 0"2
SEE DETAIL 1 FOR
CALLOUTS IN COMMON
HORIZONTAL
RESILIENT CHANNEL
@ 16" O.C. BETWEEN
STUDS & 5 8" G.W.B.
@ SIM CONDITION, ALL
MTL. STUDS & CHANNELS
SHALL BE 6"
EX. WALL w/ NEW RESIL. CHNL.
1" = 1' - 0"4
HORIZONTAL
RESILIENT CHANNEL
@ 16" O.C. BETWEEN
STUDS & 5 8" G.W.B.
EXISTING DEMISING
WALL TO REMIAN
(G.W.B. & STUDS)
3" SOUND BATT
ADJACENT TO EXISTING
DEMISING WALL
NEW HALF-WALL
1" = 1' - 0"3
3'
-
6
"
PAINTED WD.
CAP, TYP. @
HALF WALLS
35 8" MTL
CHANNEL
FASTEN TO
EX. CONC.
SLAB.
5 8" G.W.B. ON
EA. SIDE OF
35 8" MTL
STUDS
SECTION END CONDITION
MTL STUD & CHANNEL
FRAMING SHOWN DASHED.
WOOD CAP
AT OPEN END OF HALD
FALL, PROVIDE "PONY
WALL LITE" BRACE AS
MANUF. BY CLARK-DETRICH
OR APPROVED EQUAL.
NEW FURRING @ EX. EXT. WALL
1" = 1' - 0"5
EXISTING EXTERIOR
WALL TO REMAIN.
EXISTING CONCRETE
STEM WALL
5 8" G.W.B. o/ 112"
FLAT METAL STUDS
FURRING
4" RUBBER BASE, TYP.
EXISTING 4"
CONC. SLAB
FINISH FLOOR PER
FINISH PLAN SHEET A2.3
NEW FURRING @ EX. EXT. WALL
1" = 1' - 0"6
EXISTING EXTERIOR
WALL TO REMAIN.
EXISTING CONCRETE
STEM WALL
WD. CAP & APRON
FROM 1x4 TRIM.
5 8" G.W.B. o/ 112"
FLAT METAL STUDS
FURRING
4" RUBBER BASE, TYP.
EXISTING 4"
CONC. SLAB
FINISH FLOOR PER
FINISH PLAN SHEET A2.3
SE
E
F
I
N
I
S
H
P
L
A
N
S
H
E
E
T
A
2
.
3
&
I
N
T
E
R
I
O
R
EL
E
V
A
T
I
O
N
S
F
O
R
W
A
L
L
C
A
P
H
E
I
G
H
T
.
6"
NEW SUSPENDED
ACOUSTIC CLG.
WINDOW HEAD/JAMB DETAIL
1" = 1' - 0"7
5 8" G.W.B. o/ 112"
FLAT METAL STUDS
FURRING
WINDOW SILL DETAIL
1" = 1' - 0"8
EXISTING EXTERIOR
WALL TO REMAIN.
EXISTING CONCRETE
STEM WALL
4" RUBBER BASE, TYP.
EXISTING 4"
CONC. SLAB
FINISH FLOOR PER
FINISH PLAN SHEET A2.3
WD. SILL FROM 1x8 EXISTING ALUM.
FRAME WINDOW.
5 8" G.W.B. o/ 112"
FLAT METAL STUDS
FURRING
EXISTING EXTERIOR
WALL TO REMAIN.
5 8" G.W.B. WRAP EXISTING ALUM.
FRAME WINDOW.
7A5.1
SEE DETAIL ABOVEFOR JAMB & HEADCOND.
OMIT WOOD CAP @ SIM
CONDITIONS UNDER
NEW COUNTERTOPS.
2'
-
6
"
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
A5.1
225-3590
11/4/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/4/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
ARCHITECTURAL SPECIFICATIONS
A6.1
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
225-3590
11/10/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/10/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
EXAM #1103 EXAM #2104
EXAM #4111
EXAM #8114EXAM #7115EXAM #6116
EXAM #3109
TOILET #2106TOILET #1105
BREAK ROOM108
PROVIDERS113
I.T.118
WAITING ROOM101
RECEPTION102
ECHO119
LEADER112
M.A.110
JAN.107
HOTEL117
FE
EX. 4" S.S. WASTE
LINE (VERIFY
LOCATION)NEW 4" S.S. WASTE LINE
(VERIFY LOCATION)
NEW 3"Ø S.S.
WASTE LINE
NEW 3"Ø S.S.
WASTE LINE
NEW 3"Ø S.S.
WASTE LINE
EXAM #1103 EXAM #2104
EXAM #4111
EXAM #8114EXAM #7115EXAM #6116
EXAM #3109
TOILET #2106TOILET #1105
BREAK ROOM108
PROVIDERS113
I.T.118
WAITING ROOM101
RECEPTION102
ECHO119
LEADER112
M.A.110
JAN.107
HOTEL117
FE
NEW BREAK
ROOM D.W.
NEW SUPPLY FOR
REFER. ICE-MAKER
SINK
WCWC
LAV LAV
MOP SINK
ELECTRIC WATER
HEATER
ECHO ROOM
SINK
PROVIDE NEW SHUT-OFF
VALVE FROM EX. COLD
WATER SUPPLY
1"Ø COLD WATER
LINE, TYP.
1"Ø HOT WATER
LINE, TYP.
1"Ø COLD WATER
LINE, TYP.
2" VENTTHRU ROOF
2" VENTTHRU ROOF
2" VENT
THRU ROOF
2" VENTTHRU ROOF
ECHO ROOMSINK
WC
WC
MOP SINK
LAV
LAV
BREAK
ROOM SINK(TIE-IN DW)
C.O.
C.O.
C.O.C.O.
C.O.
EX. 4"Ø S.S.LINE TO MAIN
SEWER
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
P1.1
PLUMBING WASTE PLAN 00 4 8
PLAN
NORTH 225-3590
11/4/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/4/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
PLUMBING SUPPLY PLAN 00 4 8
PLAN
NORTH
PLUMBING WASTE RISER DIAGRAM
EXAM #1103 EXAM #2104
EXAM #4111
EXAM #8114EXAM #7115EXAM #6116
EXAM #3109
TOILET #2106TOILET #1105
BREAK ROOM108
PROVIDERS113
I.T.118
WAITING ROOM101
RECEPTION102
ECHO119
LEADER112
M.A.110
JAN.107
HOTEL117
FE
EX. ELEC. PANEL
TO REMAIN
EX. ELEC.
GEAR ON
EXTERIOR
WALL
GFI 44"GFI 44"
GFI 44"60"
12 SWITCHED
OUTLET FOR
DISP. & D.W.
2
+44"2+44"
+44"2+44"
GF
I
4
4
"
4
2 2 2
2 2
2 2
2
22
2
+44"
2 - 44"
+44"
2 - 44"
2
2
+44"
+44"
2 - 44"
+44"
2
2
+44"
2 - 44"
+44"
2
TV
+80"
GFI
GFI
POWER & DATA KEY
(NEW WORK)
NEW
DUPLEX OUTLET. ALL DUPLEX OUTLETS MOUNTED AT
15" ABOVE FINISH FLOOR UNLESS OTHERWISE
NOTED.
4-PLEX OUTLET MOUNTED AT 15" ABOVE FINISH
FLOOR UNLESS OTHERWISE NOTED.
STANDARD DATA OUTLET. NUMBER INDICATES
MULTI-PORT COUNT. NO NUMBER MEANS 1 PORT
DESRIPTION
DUPLEX OUTLET w/ GROUND FAULT INTERUPT
CIRCUIT @ +44" ABOVE FINISH FLOOR.
ALTERNATE HEIGHT FOR OUTLET - NUMBER
INDICATES INCHES ABOVE FIN. FLR.
COMBINATION BOX w/ POWER, CABLE FOR TV. VERIFY
OTHER INPUT CABLES AS REQUIRED BY OWNER.
NUMBER INDICATES HEIGHT ABOVE FINISH FLOOR.
DEDICATED OUTLET w/
AMPERAGE REQUIREMENT NOTED
NOTE: ALL EXISTING POWER & DATA OUTLETS TO BE REMOVED. ALL NEW
POWER & DATA OUTLETS SHALL BE PROVIDED AS FOLLOWS:
DUPLEX OUTLET w/ TOP OUTLET CONTROLLED BY
OCCUPANT SENSOR. CONTROLLED OUTLET TO BE
VISIBLY NOTED.
220 VOLT OUTLET FOR SPECIFIC EQUIPMENT.
CONFIRM ADDITIONAL REQUIREMENTS w/ OWNER.
GFI
44"
2
20 AMP
44"
TV
60"
EXISTING OUTLETS TO REMAIN MODIFY ROUGH-IN
BOX AS NEEDED FOR NEW WALL FURRING
DESRIPTIONTO BE
REMOVED
POWER & DATA KEY
(EXISTING OUTLETS)
EXISTING OUTLET ON EXTERIOR WALL TO BE
REMOVED.
BOX WALK NOTE:
CONTRACTOR SHALL COORDINATE A "BOX-WALK" w/ ARCHITECT, OWNER &
ELECTRICAL SUB-CONTRACTOR.
BOX WALK CONDITIONS MUST INCLUDE ALL OF THE FOLLOWING:
·ALL DEMOLITION HAS BEEN COMPLETED
·ALL NEW STUD WALLS ARE FRAMED WITHOUT G.W.B.
·ALL ROUGH-IN BOXES IN PLACE
·NO NEW WIRING OR CONDUIT IS IN PLACE
·JOB SITE IS GENERALLY CLEAN AND ALL WALLS & ROUGH-IN BOXES ARE
AVAILABLE FOR VISUAL INSPECTION.
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
E1.1
POWER & DATA PLAN 00 4 8
PLAN
NORTH
225-3590
11/4/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/4/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
EXAM #1103 EXAM #2104
EXAM #4111
EXAM #8114EXAM #7115EXAM #6116
EXAM #3109
TOILET #2106TOILET #1105
BREAK ROOM108
PROVIDERS113
I.T.118
WAITING ROOM101
RECEPTION102
ECHO119
LEADER112
M.A.110
JAN.107
HOTEL117
FE
B
B B
BB
A
B
BB
B
B B
B
A
A
A
C
C
A A
A
A AA
A
A
A A
B
A
B
C
B
C
C
A
C
C
A
DD
CC
$$
$$
$$$
$
$
$
$
$
$$
$
OSOS
OS OS OS
OS OS
$A $B $C $D
A
A
B
B
B
BC
C
C
C C
C C
C
C
D
D
B
DIM
G.W.B. SOFFIT
@ +8'-0" A.F.F.
G.W.B. CLG.
@ +8'-0" A.F.F.
G.W.B. CLG.
@ +8'-0" A.F.F.
ALL ACOUSTIC SUSPENDED
GRID CLGS @ +9'-0" A.F.F., TYP.
EX
I
T
EX
I
T
EX
I
T
LIGHT FIXTURE KEY
FIXTURE DESCRIPTIONFIXTURE SYMBOL
WALL MOUNTED LINEAR LED
FIXTURE @ +7'-0" ABOVE FINISH
A
2'X4' BASKET TROFFER LED
FIXTURE IN SUSPENDED GRID
CEILING
2'X2' BASKET TROFFER LED
FIXTURE IN SUSPENDED GRID
CEILING
RECESSED LED CAN LIGHT IN
SUSPENDED GRID CEILING
B
C
D
FIXTURE
WATTAGE
2'X2' BASKET TROFFER LED
FIXTURE IN SUSPENDED GRID
CEILING ON NITE-LITE CIRCUIT w/
EMERGENCY BATTERY BACKUP.
B
EXIT ILLUMINATED EXIT SIGN
w/ DIRECTIONAL ARROWS.
36 WATTS
30 WATTS
30 WATTS
14 WATTS
39 WATTS
N/A
LIGHT SWITCH KEY
OCCUPANCY SENSOR - MODIFIES ALL SWITCHES
ABOVE AS FOLLOWS:
·MANUAL CONTROL FOR "ON" OR "OFF" SETTINGS
·AUTOMATIC "OFF" CONTROL AFTER 20 MINUTES
OF OCCUPANTS LEAVING THE SPACE.
·MANUAL DIM CONTROL AT SWITCH.
$OS
STANDARD SINGLE-POLE SWITCH CONTROLLING
LIGHTS AS INDICATED WITH DASHED LINE CIRCUIT.$
STANDARD SINGLE-POLE SWITCH CONTROLLING
LIGHTS AS INDICATED WITH CORRESPONDING
LETTER.$X
SWITCH DESCRIPTIONSWITCH SYMBOL
$3 THREE-WAY SWITCH - MODIFIES ALL SWITCHES
ABOVE TO INCLUDE A 3-WAY CIRCUIT.
$TM TIMER SWITCH - MODIFIES ALL SWITCHES ABOVE TO
INCLUDE A TIMER.
$DIM DIMMER SWITCH - MODIFIES ALL SWITCHES ABOVE
TO INCLUDE MANUAL DIMMING CONTROL..
A
2'X4' BASKET TROFFER LED
FIXTURE IN SUSPENDED GRID
CEILING ON NITE-LITE CIRCUIT w/
EMERGENCY BATTERY BACKUP.
36 WATTS
RECESSED LED CAN LIGHT IN
SUSPENDED GRID CEILING
NITE-LITE CIRCUIT w/ EMERGENCY
BATTERY BACKUP.
C 14 WATTS
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
E2.1
lighting & reflected ceiling plan 00 4 8
PLAN
NORTH
225-3590
11/4/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/4/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T