Loading...
HomeMy WebLinkAboutCircleK-E093030 - Box&EquipmentSpecsCircle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 1 of 17 15600 37th Ave N, Suite 100, Plymouth, MN 55446 Phone: (763) 541.1410 or 1.800.523.7337 - Fax: (763) 541.1563 Internet: https://www.everidge.com To: From: James McLemore Circle K - West Coast (CA, OR, WA) 495 E Rincon St 150 Corona, CA 92879 Phone: 480.793.5425 Fax: 951.270.5182 Email: james.mclemore@circlek.com Josh Doran Phone: 763.210.6957 Fax: 763.541.1563 Email: Josh.Doran@everidge.com Ship To: Details: Circle K - 9269 - NWC Yelm Ave. & Killon Rd. Yelm, WA 98597 , CIRCLE K-2709269-WA,Yelm 9548 Killion Rd SE Yelm, WA 98597 Plant Code: R Sales Rep: HOUSE Dates are dependent upon receipt of Signed Approval Drawings. Quote Date: 03/21/2025 Promised Ship Date: 12/23/2025 Customer Requested Date: 12/29/2025 Customer PO#: 752340 Net Area: 2710.50 ft² Quantity Description Price 1 5200 (Smaller) *** Freezer - indoor UL Listed Class 1 Panel with NSF listed construction 1) 7' 7 1/2" x 11' 1 1/2" x 8' 0" foam rail walk-in Freezer with floor Refrigeration units: LCH0025LCACZC2463-10°F R448/R449 208-230/3/60 LEL0080BS6EEAB0200 coil -10°F R448/R449 208-230/1/60 1 5200 - *FOUNTAIN* - Cold Vault Angle/Cooler Combo (67' 4 1/4" x 11' 8 1/8") - indoor UL Listed Class 1 Panel with NSF listed construction 1) 22' 8" x 11' 8 1/8" x 10' 4" foam rail walk-in Cold Vault without floor Refrigeration units: LCH0015MCALZA000035°F R448/R449 208-230/3/60 LEC0130AS7AMAB0200 coil 35°F R448/R449 115/1/60 2) 44' 8 1/4" x 9' 1" x 8' 4" foam rail walk-in Cooler without floor Refrigeration units: LCH0035MCALZA000035°F R448/R449 208-230/3/60 LEL0095AS6AMAB0200 coil 35°F R448/R449 115/1/60 Estimated Box Installation - SCOPE Total Freight Not Included Taxes Not Included Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 2 of 17 Prices on all orders not shipped within 60 days of order may be subject to price increase. Prices on resale items may be adjusted at any time due to supplier tariff surcharges. Need approved drawings min 3 weeks before shipment. Please consult with your local authorities for all code requirements. Customer is responsible for verifying code requirements for this project for the area. Please sign below to accept this as an order and request an on-site date: Accepted By: ________________________ Date: ___________________ Desired On-site Date:__________ Able to accept early? Yes No Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 3 of 17 Panel Installation E093030 - Circle K - 5200 Yelm, WA CIRCLE K PROTO – 5200 SOW Cooler/Cold Vault and Stand Alone Freezer Panel Installation SCOPE OF WORK INCLUDES: Manufacturer Authorized Installer to install the walk-in compartment Coordinate delivery date with Site GC Unload shipment from transport carrier w/ site lull Install walk-in panels including butyl Seal interior perimeter and anchor floorless compartment(s) to slab Cove trim installation Return Trip for glass door installation Install 21-Anthony reach-in glass door Install 1-Pass Through Glass Door Install 1- Anthony glass window Test and adjust walk-in doors and closers as needed Remove all protective panel coverings Removal of debris in customer supplied dumpster SCOPE OF WORK DOES NOT INCLUDE: Demolition/removal of existing walk-in equipment and structure Slab preparation Tile work Structural Steel Wainscot installation Power supply for heated pressure relief vent, lights, and door jamb heater Mounting of light fixtures Fire Suppression work Refrigeration Installation SCOPE OF WORK INCLUDES: Mount 5 evaporator coils 1 x LEL0080BS6EEAB0200 1 x LEC0130AS7AMAB0200 3 x LEL0095AS6AMAB0200 Placement of 3 roof level condensing units 1 x LCH0025LCACZC2463 1 x LCH0015MCALZA0000 1 x LCH0035MCALZA0000 Hard pipe refrigeration system between condensing units & coils (up to 50’ line-set included. Additional charges will apply for longer runs.) Condensate lines, insulation, and heat trace to nearest floor drain Placement of rooftop condensing units w/ site lull Return trip for start, run, and test systems Mechanical refrigeration permits Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 4 of 17 Removal of debris in customer supplied dumpster SCOPE OF WORK DOES NOT INCLUDE: Demolition of refrigeration equipment Condensing unit curbs/stands for customer’s roof Roof top pitch pockets for customers building Power and any wiring for condensing units Power and any wiring to evaporators Power and any wiring to lights Water supply for water cooled units to be plumbed by others except final connection ADDITIONAL CHARGES WILL APPLY IF: Work cannot be performed between 8:00 AM to 5:00 PM Union/Prevailing wages are required *This quote is subject to change based on unforeseen site conditions *This quote assumes panel installation in one phase. *Additional charges will apply for core drilling and sealing roof penetrations if not completed by others *This quote includes one return trip to install Anthony glass doors *This installation price is subject to change based on regional labor costs *Any required permitting by others *This quote includes one return trip for start-up of refrigeration *This quote DOES NOT include a forklift rental for off-loading and moving materials Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 5 of 17 Box description: 5200 (Smaller) *** Freezer □ Approved as submitted □ NOT APPROVED – Revise and resubmit for approval Before signing this document, verify that the content you are signing is correct. X Accepted By: Date: Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 6 of 17 Box description: 5200 (Smaller) *** Freezer -- Right elevation □ Approved as submitted □ NOT APPROVED – Revise and resubmit for approval Before signing this document, verify that the content you are signing is correct. X Accepted By: Date: Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 7 of 17 Box description: 5200 (Smaller) *** Freezer Dimensions: External (O.D.): 7' 7 1/2" x 11' 1 1/2" x 8' 0" - w x d x h Internal (I.D.): 6' 11 1/2" x 10' 5 1/2" x 7' 3 7/8" - w x d x h Volume: 533 ft³ / E093030-01 Ceiling Load: 10 psf Finishes Walls: Galvanized/Embossed - 26 Ga. - interior & exterior Floors: Aluminum Diamond Tread Brite - .125 - interior Galvanized/Embossed - 26 Ga. - exterior Ceilings: Galvanized/Embossed - 26 Ga. - interior & exterior Panel Thickness Walls: 4" UL Listed Class 1 Foam Floors: 4.125" UL Listed Class 1 Foam cart floor, designed to support 1000 lb/ft² - 175 lb cart load and 3,735 lb/ft² uniform load (single layer of 5/8" underlayment in floor) Ceilings: 4" UL Listed Class 1 Foam Qty Description Qty Description Door D01 1 Finished opening 36" x 84" hinged flush freezer door 1 Heated Jamb, NO Threshold heat 1 Heat In Bottom Of Door 1 Threshold, Internal Ramp Unheated 1 Gasket- Magnetic 1 Kick plate: 36" 1279 - interior and exterior of door 1 Latch - 78CL - Chrome Locking (Safeguard Radial Latch) 1 Kason 487-C 4" (Frost-Free Push Handle) 1 Door Closer - Kason 1094 Sureclose™ Hydraulic (Concealed Mounting) 2 Kason 1346 Hinge 1 Thermometer Dial 2.5" 4' Probe (STD) 1 Switch W/ Pilot Light 2-Way Ivory (Shipped Loose) 1 Ramp/24" Deep, Interior Accessories 4 Caulk - Silicone Grey (Tubes) 1 Lag Down Walls to Ceiling - Field Installed Trim Caps 17 Lock Wall Panels to Floor Panels 19 Caulk - Butyl (Tubes) 21 Lag Bolt - 3/8" x 6" - With Washer 1 Vent - 115V Hi Flow Non-Heated Pressure Relief Port (Kason 1836) 1 LCH0025LCACZC2463 with -10°F R448/R449 208-230/3/60 - FOB factory 1 LEL0080BS6EEAB0200 coil -10°F R448/R449 208-230/1/60 - FOB factory 1 LCH0025LCACZC2463 Warranty (Compressor-motor warranty extended to 5-years, part only, no labor) - FOB factory 1 LIGHT LED 45W 48" EVERIDGE 21 LAG SCREW 3/8-7 X 8 HEX HEAD GRADE A ZINC 21 WASHER USS F/W 3/8 Z Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 8 of 17 Refrigeration Condensing Unit for Freezer - Refrigeration system is designed to maintain -10°F at 80°F ambient temperature around box and 95°F outdoor ambient temperature assuming products enter at -10°F with moderate traffic. • Manufacturer: Heatcraft DOE • Description: Low Temp Air Cooled Scroll Condensing Unit with microchannel condenser, Liquid Line Filter/Drier and Sight Glass. • Model: LCH0025LCACZC2463 • Horsepower: 2.5hp • Extras: • Electrical: 208-230/3/60, RLA 8.65385, MOPD 30, MCA 28.8 • Conditions: BTUH: 8290 Room Temp: -10°F Ambient: 95°F • Warranty: Compressor-motor warranty extended to 5-years, parts only, no labor 1 x Evaporator (Unit cooler) • Manufacturer: Heatcraft DOE • Description: Electric defrost Low profile coil (unit cooler) with EC fan motors, Electric Expansion Valve and iNtelliGen Controller. coil • Model: LEL0080BS6EEAB0200 • Extras: None • Electrical: 208-230/1/60, Fan amps 1, Defrost amps 9.1 Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 9 of 17 Box description: 5200 - *FOUNTAIN* - Cold Vault Angle/Cooler Combo □ Approved as submitted □ NOT APPROVED – Revise and resubmit for approval Before signing this document, verify that the content you are signing is correct. X Accepted By: Date: Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 10 of 17 Box description: 5200 - *FOUNTAIN* - Cold Vault Angle/Cooler Combo -- Front elevation 808 1/4" 79 1 / 4 " 5" 79 1 / 4 " 5" 96 " 4" 522 7/16"522 7/16"123 3/8"123 3/8" 10 0 " 12 0 " 4" 12 4 " □ Approved as submitted □ NOT APPROVED – Revise and resubmit for approval Before signing this document, verify that the content you are signing is correct. X Accepted By: Date: Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 11 of 17 Box description: 5200 - *FOUNTAIN* - Cold Vault Angle/Cooler Combo -- Right elevation □ Approved as submitted □ NOT APPROVED – Revise and resubmit for approval Before signing this document, verify that the content you are signing is correct. X Accepted By: Date: Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 12 of 17 Box description: 5200 - *FOUNTAIN* - Cold Vault Angle/Cooler Combo Dimensions: External (O.D.): 67' 4 1/4" x 11' 8 1/8" x 10' 4" - w x d x h Compartment 1 - Cold Vault: Internal (I.D.): 22' 0" x 11' 1/8" x 10' 0" - w x d x h (non-rectangular) Volume: 2248 ft³ / E093030-02 Compartment 2 - Cooler: Internal (I.D.): 44' 4 1/4" x 8' 5" x 8' 0" - w x d x h Volume: 2987 ft³ / E093030-02 Ceiling Load: 10 psf Finishes Walls: Galvanized/Embossed - 26 Ga. & Galvanized/Embossed White - 26 Ga. - interior Galvanized/Embossed - 26 Ga. - exterior Ceilings: Galvanized/Embossed White - 26 Ga. - interior Galvanized/Embossed - 26 Ga. - exterior Panel Thickness Walls: 4" UL Listed Class 1 Foam Ceilings: 4" UL Listed Class 1 Foam Qty Description Qty Description Door D01 1 Finished opening 36" x 84" hinged flush cooler door 1 Threshold, Floorless Unheated 1 Gasket- Magnetic 1 Kick plate: 36" 1279 - interior and 35.125" 1279 - exterior of door 1 Kick plate: 36" 1279 - exterior of jamb 1 Latch - 78CL - Chrome Locking (Safeguard Radial Latch) 1 Kason 487-C 4" (Frost-Free Push Handle) 1 Door Closer - Kason 1094 Sureclose™ Hydraulic (Concealed Mounting) 2 Kason 1346 Hinge 1 Thermometer Dial 2.5" 4' Probe (STD) 1 Switch W/ Pilot Light 2-Way Ivory (Shipped Loose) Door D02 1 Finished opening 36" x 84" hinged flush cooler door 1 Threshold, Floorless Unheated 1 Gasket- Magnetic 1 Kick plate: 36" 1279 - interior and 35.125" 1279 - exterior of door 1 Kick plate: 36" 1279 - exterior of jamb 1 Latch - 78CL - Chrome Locking (Safeguard Radial Latch) 1 Kason 487-C 4" (Frost-Free Push Handle) 1 Door Closer - Kason 1094 Sureclose™ Hydraulic (Concealed Mounting) 2 Kason 1346 Hinge 1 Thermometer Dial 2.5" 4' Probe (STD) 1 Switch W/ Pilot Light 2-Way Ivory (Shipped Loose) Openings 1 D04: Anthony 101 - w/ Mullion glass door, NCPO 123 3/8"W x 79 1/4"H (4 x 30"Wx79"H), 5" sill 1 D05: Anthony 103 glass door, NCPO 37 5/8"W x 81 1/8"H (1 x 36"Wx81"H) 1 Opening only, NCPO 23"W x 60"H, Fixed Window HH, NCO 60"H x 23"W, Black finish Smooth, with trim frame (separate) NCO - 60"H x 23"W - Side Lite Unit, 21 1/8" sill 1 D03: Anthony 101 - w/ Mullion glass door, NCPO 522 7/16"W x 79 1/4"H (17 x 30"Wx79"H), 5" sill Accessories 19 Caulk - Silicone Grey (Tubes) 4 Angular Panels- Wall Or Ceiling 1 Lag Down Walls to Ceiling - Field Installed Trim Caps 5 Header Brace Bracket - Standard 20 Caulk - Butyl (Tubes) 7 Caulk - Silicone White (Tubes) 91 Lag Bolt - 3/8" x 6" - With Washer 28 Ceiling Hanger Brackets (no rods) - foam rail 56 Nails - Ceiling Bracket (2 per bracket) 2 Vent - 115V Hi Flow Non-Heated Pressure Relief Port (Kason 1836) Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 13 of 17 1 LCH0015MCALZA0000 with 35°F R448/R449 208-230/3/60 - FOB factory 1 LEC0130AS7AMAB0200 coil 35°F R448/R449 115/1/60 - FOB factory 1 LCH0015MCALZA0000 Warranty (Compressor-motor warranty extended to 5-years, part only, no labor) - FOB factory 1 Quanity of 4 doors; Model 101 NT HH 30x79 - COOLER Energy Free Door (3 pane non-heated dual reflective, argon gas filled) Low Energy Hybrid Frame Full-Length Handle Cylinder Lock Energy Controller LED Lighting – Optimax Radiant 045 Life Plus Gasket (3-year gasket warranty) Data label on doors and frames certifies D.O.E. Compliance Black Finish Left Hinge NO Shelves - FOB factory 1 Quanity of 1 door; Model 103 36x81 Energy Free Door (3 pane non-heated dual reflective, argon gas filled) Low Energy Hybrid Frame, With Lights (LED Lighting – OP7 LED) With Threshold, Full Length handle, NO MULLION pom lock to be wired w/indmdual switch 10” SST. Kickplates int and ext, interior push bar and Anthyony smart energy controller Black Finish include green auto lock button Right Hinge No - Bumper Bar - FOB factory 1 Quantity of 1 - Anthony "Model 1963 NORMAL-TEMP Window 1 Set of 1 ***** 3 TO 4-1/2 WALL THICKNESS*** Net Opening: 23"W x 60"H (1) Glass: WE2RA 2-Pane NHG,Reflective,Warm Edge,w/Argon SGU Thickness: 1" Glass Logo: ANTHONY Doors are Narrow Black Door Heaters Sys Volts:120 Hertz:60 - Freight allowed 1 LCH0035MCALZA0000 with 35°F R448/R449 208-230/3/60 - FOB factory 3 LEL0095AS6AMAB0200 coil 35°F R448/R449 115/1/60 - FOB factory 1 LCH0035MCALZA0000 Warranty (Compressor-motor warranty extended to 5-years, part only, no labor) - FOB factory 1 Quanity of 17 doors; Model 101 NT HH 30x79 - COOLER Energy Free Door (3 pane non-heated dual reflective, argon gas filled) Low Energy Hybrid Frame Full-Length Handle Cylinder Lock Energy Controller LED Lighting – Optimax Radiant 045 Life Plus Gasket (3-year gasket warranty) Data label on doors and frames certifies D.O.E. Compliance Black Finish Left Hinge NO Shelves - FOB factory 10 LIGHT LED 45W 48" EVERIDGE 91 LAG SCREW 3/8-7 X 8 HEX HEAD GRADE A ZINC 91 WASHER USS F/W 3/8 Z 82 BOLT 1/4 X 1-1/4 ANCHOR PIN DRIVE STEEL HAMMER 25 SCREED GRAY U-SHAPED NON-LOCKABLE 4 VINYL (EA) Miscellaneous 1 No switch, gauge or vent exposed to sales floor Box Notes Columns on order are NOT true columns, please put a square on the submittal calling it blocked corner. Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 14 of 17 Refrigeration Condensing Unit for Cold Vault - Refrigeration system is designed to maintain 35°F at 80°F ambient temperature around box and 95°F outdoor ambient temperature assuming products enter at 35°F with moderate traffic. • Manufacturer: Heatcraft DOE • Description: Med Temp Air Cooled Scroll Condensing Unit with microchannel condenser, Liquid Line Filter/Drier and Sight Glass. • Model: LCH0015MCALZA0000 • Horsepower: 1.5hp • Extras: • Electrical: 208-230/3/60, RLA 6.41026, MOPD 15, MCA 15 • Conditions: BTUH: 13890 Room Temp: 35°F Ambient: 95°F • Warranty: Compressor-motor warranty extended to 5-years, parts only, no labor 1 x Evaporator (Unit cooler) • Manufacturer: Heatcraft DOE • Description: Air defrost Center mount coil (unit cooler) with EC fan motors, Electric Expansion Valve and iNtelliGen Controller. coil • Model: LEC0130AS7AMAB0200 • Extras: None • Electrical: 115/1/60, Fan amps 1.68, Defrost amps N/A Condensing Unit for Cooler - Refrigeration system is designed to maintain 35°F at 80°F ambient temperature around box and 95°F outdoor ambient temperature assuming products enter at 35°F with moderate traffic. • Manufacturer: Heatcraft DOE • Description: Med Temp Air Cooled Scroll Condensing Unit with microchannel condenser, Liquid Line Filter/Drier and Sight Glass. • Model: LCH0035MCALZA0000 • Horsepower: 3.5hp • Extras: • Electrical: 208-230/3/60, RLA 11.5385, MOPD 25, MCA 20 • Conditions: BTUH: 32610 Room Temp: 35°F Ambient: 95°F • Warranty: Compressor-motor warranty extended to 5-years, parts only, no labor 3 x Evaporator (Unit cooler) • Manufacturer: Heatcraft DOE • Description: Air defrost Low profile coil (unit cooler) with EC fan motors, Electric Expansion Valve and iNtelliGen Controller. coil • Model: LEL0095AS6AMAB0200 • Extras: None • Electrical: 115/1/60, Fan amps 1.8, Defrost amps N/A Customer Please Note: a) All Orders shall be subject to CrownTonka division of Everidge Inc. standard terms and conditions notwithstanding and additional or contrary terms and conditions of Buyer. Such additional or contrary terms shall not bind Everidge Inc. unless accepted in writing even though such terms do not materially alter the terms hereof. No oral statements, warranties, stipulations, representations or terms shall be binding when out order acknowledgement is mailed, faxed or emailed. If customer does not have a copy of these terms and conditions, please contact customer service department. b) Prices on all orders not shipped within 60 days or order may be subject to increase. c) Ship date is determined upon receipt of signed approval drawings. APPROVALS are required a miniumum of 8 weeks prior to ship date. d) Terms: subject to credit approval. e) Actual freight charges may differ from estimate. Please RESALE section for item(s) freight estimate. f) Any changes made to an order after the order has been released for production, may be subjected to additional charges and may delay shipment. Thank you for your order. Sincerely, Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 15 of 17 Josh Doran (763.210.6957) Sales Department Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 16 of 17 Circle K - West Coast (CA, OR, WA) Order Acknowledgement Order #: E093030 Order Date: 09/02/2025 Revision: 03/21/2025(#0) 17 of 17 EVERIDGE, Terms & Conditions of Sale 1. Orders. Orders must be in writing, are binding only upon acceptance by Seller and must specify type and quantity of Product, specifications and, if Seller is to provide installation services, installation plans. Prices on all orders not shipped within 60 days of order may be subject to price increase. 2. Payments. Due in full 30 days after shipment. Past due invoices subject to interest at 1½% per month (18% per year). Seller may partial bill if Buyer delays shipment more than one week after product is manufactured, installation is not complete within one week after shipment or delivery is scheduled at weekly or greater interval. Seller may file material and mechanics liens and Buyer shall pay all costs and attorneys’ fees incurred if Seller initiates collection or legal proceedings. Terms of sale are subject to credit approval. 3. Delivery; Risk of Loss. Delivery dates are approximate and failure to meet estimated delivery dates is not grounds for cancellation. Transportations costs will be invoiced to Buyer at cost plus handling. Risk of loss or damage from Seller’s factory or at an installation site is Buyer’s risk, whether or not Seller performs installation. Buyer shall verify condition, quantity and quality of Product, note on the freight bill any damage or shortage and immediately file a claim with carrier. 4. Changes. Change orders must be authorized by Seller in writing. Seller shall have the right to adjust price and completion date in the event of latent, concealed or unknown conditions which differ materially from description of installation. Cancelled orders are subject, in Seller’s sole discretion, to total invoice amount less freight, taxes, etc. or a restocking fee based on complexity and completeness of the order. Products cannot be returned without Seller’s written permission. If permitted, Buyer shall pay all transportation charges. 5. Installation. Buyer shall provide all information, drawings, records, utility locations, documentation and specifications concerning Product and installation if installation is requested. Buyer is responsible for utilities, access to work, parking and storage areas and sanitation facilities, shall comply with all laws and regulations, shall cooperate with Seller on job site safety matters, shall coordinate installation performed by Buyer or its contractors so as not to interfere with or delay Seller’s performance. Buyer shall reimburse Seller for any additional cost caused by Buyer or its contractors or changes to Seller’s installation. Buyer shall maintain property insurance acceptable to Seller, naming Seller as a named insured. 6. Delays; Nonperformance. Seller shall not be liable for loss or damage due to delay o r nonperformance in manufacture, delivery or installation resulting from any cause beyond Seller’s reasonable control. 7. IN NO EVENT SHALL SELLER BE LIABLE FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES ARISING FROM DELAY OR FAILURE OF DELIVERY OR INSTALLATION. 8. Taxes. Buyer is responsible for any sales, use, excise or similar tax arising from the sale Product or services. Buyer shall pay or reimburse Seller for any such taxes. 9. Limited Warranty. One year from date of installation by authorized representative, not to exceed one year and three months of original shipment to original Buyer as follows: (a) foamed-in-place panels free from defects in material and workmanship under normal use and service; (b) pre-painted surfaces free from paint failure under normal use and service; and (c) hardware and electrical components free from defects in material and workmanship under normal use and service. Limited Warranty does not apply to the refrigeration system. Seller, at its option, will repair or exchange Products or parts covered by warranty. Buyer must notify Seller within 30 days of knowledge of problem or warranty is void. Buyer must obtain written authorization for return of Products. Limited Warranty does not include transportation costs, cost of removing defective parts or costs of reinstallation and does not apply to any Product or part subject to misuse, damage in transit, accident, negligence, alteration, improper installation or operation or to Product located outside the continental U.S. Limited Warranty does not apply to Product or parts supplied by Seller but manufactured by other companies. In no event shall Seller be liable for loss of use, revenue or profit or for any other indirect, incidental, special or consequential damages, including food spoilage, product loss or labor costs. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN OR ORAL, STATUTORY, EXPRESS, OR IMPLIED (INCLUDING ALL WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AND ALL WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE). This Limited Warranty is Seller’s sole and exclusive liability and Buyer’s sole and exclusive remedy, whether in tort (including negligence), strict liability or otherwise. This Limited Warranty is not transferable. 10 Indemnification. Buyer shall indemnify Seller and its employees and agents from any loss, damage or expense, including attorney’s fees, arising from or relating to transportation, installation, use or performance of any Product unless the claim arises directly from a Product defect covered by the Limited Warranty. Indemnification for employee claims shall not be limit ed by applicable worker’s compensation, disability or other employee benefit acts. 11. Governing Law; Variation of terms. The rights and obligations of Seller shall be governed by the laws of the State of Minnesota. No waiver, modification or addition to terms shall bind Seller unless agreed to in writing by Seller. The provisions hereof are intended to be a final expression of the agreement of Seller and Buyer and are intended as an exclusive statement of all terms applicable to Buyer’s order. April 2012