HomeMy WebLinkAboutCircleK-E093030 - Approval Drawing-10°F Freezer QE093030-01 4" walls, 4" ceiling, 4 1/8" NSF Cart Floor 96" high, foam rail, lag-down w/o fascia Lock walls to floor Decking: single .625" plywood Int/ext: Galvanized/Embossed - 26 Ga. Floor int: Aluminum Diamond Tread Brite - .125 Floor ext: Galvanized/Embossed - 26 Ga. AIR AIRHE A T C R A F T LE L 0 0 8 0 B S 6 E E A B 0 2 0 0 11 ' - 1 1 / 2 " [ 1 3 3 . 5 0 0 0 ] 7'-7 1/2" [91.5000] 24" RAMP V5" 8" 1 36 " $$ T D01 6' - 6 3 / 8 " [ 7 8 . 3 7 5 0 ] 1' - 7 1 / 8 " 1' - 3 1 / 8 " 11 ' - 1 1 / 2 " [ 1 3 3 . 5 0 0 0 ] 7'-7 1/2" [91.5000] 3 Q-01 3 8' - 0 " [ 9 6 . 0 0 0 0 ] T.O. CEILING PANELS B.O. FLOOR PANELS D01 2 1 INSULATED WALL PANEL SEALANT (INCLUDED) CAM WALLS TO FLOOR INSULATED FLOOR PANEL WITH INTEGRATED 3/8" RADIUS NSF COVE (STANDARD) DETAIL @ STANDARD FLOOR (NON-RECESSED APPLICATION) - LOCK TO WALLS, FOAM RAIL FOAM RAIL BLOCKING TO SUPPORT SADDLE AND UNDERLAYMENT. 12" SPACING AROUND PERIMETER OF WALK-IN. 6" SPACING THRU DOOR OPENING WIDTH LAG DOWN - NON FASCIA (FIELD INSTALLED CAPS) FOAM RAIL INSULATED WALL PANEL INSULATED CEILING PANEL 3/8" LAG BOLT W/ WASHER FIELD INSTALLED TRIM CAP (STD.) HEX HEAD SCREWS 5/8" BLOCKING DETAIL @ FLUSH MOUNT FREEZER DOOR WITH INTERIOR RAMP, HEAT IN BOTTOM OF DOOR CONCRETE SLAB INSULATED DOOR PANEL HEATED (120)V ADJUSTABLE DOOR DRAGGER THRESHOLD NEOPRENE WIPERS 1 - DOOR LOCATION UPDATED. 10 . 0 3 . 2 0 2 5 SD REV DATE BYDESCRIPTION ·ALL ELECTRICAL COMPONENTS WITHIN THE WALK-INS. I.E. PRESSURE RELIEF PORTS, JAMB HEATERS SHALL BE FACTORY PRE-WIRED, FOR HOOK UP BY ELECTRICAL CONTRACTOR. ·ALL LIGHT FIXTURES SUPPLIED ARE SHIPPED LOOSE FOR INSTALLATIONS BY ELECTRICAL CONTRACTOR. ·CrownTonka SHALL ACCEPT NO RESPONSIBILITY FOR ANY BACK CHARGES ASSOCIATED WITH INSTALLATION OF LIGHT FIXTURES OR FIELD WIRING CONNECTIONS. ELECTRICAL NOTICE REFERENCE SYMBOL LEGEND T-MOLDING (Opening Finish) DAIRY LIP (Opening Finish) JAMB GUARDS (Opening Finish) TM ELEVATION REF. DWG NUMBER SECTION REF. DWG NUMBER DETAIL REF. DWG NUMBER KEY NOTE DOOR TAG DATUM POINT DL JG REVISION NUMBERX X X X X X X X X X DXX COMPLIANCE WALK-INS MEET OR EXCEED ALL PRESCRIPTIVE STANDARDS OF THE ENERGY INDEPENDENCE AND SECURITY ACT (EISA) OF 2007 CONSTRUCTION (STANDARD) ·CORNERS AND T-WALLS TO BE ONE PIECE CONSTRUCTION W/ 3/8" RADIUS AT ALL INSIDE VERTICAL CORNERS, JOINTS SEALED W/ PVC GASKET AT INT. & EXT. PERIMETER OF PANELS, CONNECTED W/ CAM-LOCK FASTENERS. ·ALL CEILING AND WALL PANELS ARE NOT DESIGNED TO CARRY ADDITIONAL CONDENSING UNIT WEIGHT UNLESS SPECIFICALLY NOTED OTHERWISE AND DESIGNATED IN PLAN ·TO AVOID DOOR GASKET DAMAGE: DO NOT ENERGIZE FREEZER DOOR HEATERS PRIOR TO STARTUP OF REFRIGERATION ·TO AVOID DISCOLORATION OF METAL ON PANELS: PROPERLY VENTILATE EACH ROOM IF TILE OR MASONRY WORK IS TO BE DONE WARNINGS: SITE NOTATION ·WHEN APPLICABLE - DOES BUILDING FLOOR HAVE TILE AND GROUT INSTALLED BEFORE OR AFTER WALK-IN INSTALLATION IF SO PROVIDE TILE THICKNESS _______ ·ALLOW 2" FOR COOLER AND FREEZER MINIMUM AIR SPACE ALL AROUND WALK-IN FOR AMPLE AIR CIRCULATION *FOR APPROVAL ONLY* ·SLAB / PAD MUST BE LEVEL WITHIN 1/4" OVER 10'-0" IN ANY DIRECTION. ·SLAB / PAD MUST BE FLAT, SMOOTH, AND UNIFORM WITH MAXIMUM 1/4" TOTAL DEVIATION OVER 10'-0" STRAIGHTEDGE IN ANY DIRECTION. CONCRETE SLAB / PAD NOTICE X I HEREBY ACKNOWLEDGE THAT I HAVE BEEN INFORMED OF THE ABOVE SLAB / PAD REQUIREMENTS AND FAILURE TO COMPLY WILL RESULT IN REFUSAL TO INSTALL AND/OR WILL VOID ANY WARRANTY COVERAGE FOR ISSUES ON THIS WALK-IN RESULTING FROM SUCH INSTALLATION. REFRIGERATION APPROVAL INITIALS: *REFRIGERATION ON PLAN VIEW IS NOT FOR INSTALLATION PURPOSES - INSTALLATION TO BE BY REFRIGERATION CONTRACTOR* APPROVAL INITIALS: 1 WALL & CEILING PANEL PLAN 3/8" = 1'-0"Q-01 APPROVAL INITIALS: 2 FLOOR PANEL PLAN 3/8" = 1'-0"Q-01 APPROVAL INITIALS: 3 ELEVATION 3/8" = 1'-0"Q-01 KEY NOTESX APPROVAL INITIALS: 1.PRESSURE RELIEF VENT: KASON 1836 (NON HEATED) 2.LIGHT LED 45W 48" EVERIDGE 3.RAMP/24" DEEP, INTERIOR ULNSF® 15600 37TH AVE N. SUITE 100 PLYMOUTH, MN 55446 PHONE (763) 541-1410 FAX (763) 541-1563 Site Information Customer Service Rep. Submittal Drafter Shop Drafter Create Dwg Date: Customer/Dealer Save Dwg Date: Drawing Reviewed By: Review Date: Approved as Drawn: Revise and Resubmit: Please Check Appropriate Field Approval Status Block CLA S S I F I ED ® Project # Sheet # JOSH DORAN SD 08/13/2025 CIRCLE K-WEST COAST (CA,OR,WA) 495 E RINCON ST 150 CORONA, CA 92879 CIRCLE K - 9269 - NWC YELM AVE. & KILLON RD. YELM, WA 98597 08/13/2025 E093030-01 Q-01 APPROVAL INITIALS:BOX DESCRIPTION INSULATED WALL PANEL POWER SUPPLY & FIELD WIRING BY ELECTRICIAN INSULATED CEILING PANEL 6" AP P R O X . ℄ PILOT LIGHT SWITCH - STUB OUT THRU WALL PILOT LIGHT SWITCH INTERIOR 48" A.F.F. ℄ 1/2" CONDUIT FOR U.S.A. 3/4" CONDUIT FOR CANADA BLACKHOT WHITENEUTRAL REDLOAD/LIGHTS GREENGROUND CUSTOMER CONNECTIONS 4" x 4" JUNCTION BOX STUB OUT THROUGH INT PILOT LIGHT SWITCH WIRING (SINGLE POLE SWITCHING) FRONT VIEW RE D ( L O A D ) GREEN (GND) WHITE (NEUTRAL) BLACK (LINE) FROM SUPPLY TO LIGHTS WH I T E ( N E U T R A L ) JAMB HEATER WIRED (3 - SIDED HEAT) WH I T E ( N E U T R A L ) GR E E N ( G N D ) BL A C K ( L I N E ) J-BOX TO HEATER TRACK TO HEATED VENT HEATER WIRE ON JAMB ALONG THE LENGTH FROM SUPPLY EVERIDGE 4' LED LIGHT FIXTURE - STUB THRU INTERIOR CONDUIT FOR 120V POWER TO LIGHT FIXTURE( BY OTHERS) VAPOR PROOF LIGHT FIXTURE FROM SWITCH RE D ( L O A D ) WH I T E ( N E U T R A L ) INSULATED CEILING PANEL JUNCTION BOX LN ELECTRICAL INFORMATION ITEM DESCRIPTION QTY.VOLTAGE (V) (EA) AMPS (A) (EA) DOOR : 36"X 84" (3- SIDED HEAT & HEAT AT BOTTOM OF THE DOOR)1 120 1.05 EVERIDGE 4' LED LIGHT (45W)1 120 0.38 REV DATE BYDESCRIPTION ·ALL ELECTRICAL COMPONENTS WITHIN THE WALK-INS. I.E. PRESSURE RELIEF PORTS, JAMB HEATERS SHALL BE FACTORY PRE-WIRED, FOR HOOK UP BY ELECTRICAL CONTRACTOR. ·ALL LIGHT FIXTURES SUPPLIED ARE SHIPPED LOOSE FOR INSTALLATIONS BY ELECTRICAL CONTRACTOR. ·CrownTonka SHALL ACCEPT NO RESPONSIBILITY FOR ANY BACK CHARGES ASSOCIATED WITH INSTALLATION OF LIGHT FIXTURES OR FIELD WIRING CONNECTIONS. ELECTRICAL NOTICE COMPLIANCE WALK-INS MEET OR EXCEED ALL PRESCRIPTIVE STANDARDS OF THE ENERGY INDEPENDENCE AND SECURITY ACT (EISA) OF 2007 CONSTRUCTION (STANDARD) ·CORNERS AND T-WALLS TO BE ONE PIECE CONSTRUCTION W/ 3/8" RADIUS AT ALL INSIDE VERTICAL CORNERS, JOINTS SEALED W/ PVC GASKET AT INT. & EXT. PERIMETER OF PANELS, CONNECTED W/ CAM-LOCK FASTENERS. ·ALL CEILING AND WALL PANELS ARE NOT DESIGNED TO CARRY ADDITIONAL CONDENSING UNIT WEIGHT UNLESS SPECIFICALLY NOTED OTHERWISE AND DESIGNATED IN PLAN ·TO AVOID DOOR GASKET DAMAGE: DO NOT ENERGIZE FREEZER DOOR HEATERS PRIOR TO STARTUP OF REFRIGERATION ·TO AVOID DISCOLORATION OF METAL ON PANELS: PROPERLY VENTILATE EACH ROOM IF TILE OR MASONRY WORK IS TO BE DONE WARNINGS: SITE NOTATION ·WHEN APPLICABLE - DOES BUILDING FLOOR HAVE TILE AND GROUT INSTALLED BEFORE OR AFTER WALK-IN INSTALLATION IF SO PROVIDE TILE THICKNESS _______ ·ALLOW 2" FOR COOLER AND FREEZER MINIMUM AIR SPACE ALL AROUND WALK-IN FOR AMPLE AIR CIRCULATION *FOR APPROVAL ONLY* ·SLAB / PAD MUST BE LEVEL WITHIN 1/4" OVER 10'-0" IN ANY DIRECTION. ·SLAB / PAD MUST BE FLAT, SMOOTH, AND UNIFORM WITH MAXIMUM 1/4" TOTAL DEVIATION OVER 10'-0" STRAIGHTEDGE IN ANY DIRECTION. CONCRETE SLAB / PAD NOTICE X I HEREBY ACKNOWLEDGE THAT I HAVE BEEN INFORMED OF THE ABOVE SLAB / PAD REQUIREMENTS AND FAILURE TO COMPLY WILL RESULT IN REFUSAL TO INSTALL AND/OR WILL VOID ANY WARRANTY COVERAGE FOR ISSUES ON THIS WALK-IN RESULTING FROM SUCH INSTALLATION. NOTE: REFRIGERATION AND LIGHTING TO FOLLOW IFC PERMITTING PLAN ULNSF® 15600 37TH AVE N. SUITE 100 PLYMOUTH, MN 55446 PHONE (763) 541-1410 FAX (763) 541-1563 Site Information Customer Service Rep. Submittal Drafter Shop Drafter Create Dwg Date: Customer/Dealer Save Dwg Date: Drawing Reviewed By: Review Date: Approved as Drawn: Revise and Resubmit: Please Check Appropriate Field Approval Status Block CLA S S I F I ED ® Project # Sheet # JOSH DORAN SD 08/13/2025 CIRCLE K-WEST COAST (CA,OR,WA) 495 E RINCON ST 150 CORONA, CA 92879 CIRCLE K - 9269 - NWC YELM AVE. & KILLON RD. YELM, WA 98597 08/13/2025 E093030-01 QE-01 1 - DOOR LOCATION UPDATED. 10 . 0 3 . 2 0 2 5 SD 3 Q-01DL 9' - 6 7 / 8 " [ 1 1 4 . 8 7 5 0 ] 22'-8" [272.0000] 67'-4 1/4" [808.2500] V $$ 36" DEEP SHELVING HEATCRAFT LEC0130AS7AMAB0200 10 5/16" 10"123 3/8" D04 4'-5" DL DL 23" D 06 6"3" 37 5/8 " D 05 5" 3' - 5 " 2' - 4 " 36 " D01 36" DEEP SHELVING 522 7/16" D03 6 15/16" DL V 1 $$ 3' - 9 " 2' - 4 " 36 " D02 1' - 0 " 2' - 1 1 / 4 " 11 ' - 8 1 / 8 " [ 1 4 0 . 1 2 5 0 ] 44'-8 1/4" [536.2500] 9' - 1 " [ 1 0 9 . 0 0 0 0 ] 25° T 2 5 ° 10 ' - 4 " [ 1 2 4 . 0 0 0 0 ] T.O. CEILING PANELS COLD VAULT B.O. PANELS T.O. CEILING PANELS COOLER B.O. PANELS 8' - 4 " [ 1 0 0 . 0 0 0 0 ] 79 1 / 4 " D04 5" 60 " 1' - 9 1 / 8 " D06 D05 79 1 / 4 " 5" D03 D02D06 60 " 1' - 9 1 / 8 " 81 1 / 8 " D05 81 1 / 8 " 10 ' - 4 " [ 1 2 4 . 0 0 0 0 ] T.O. CEILING PANELS COLD VAULT B.O. PANELS T.O. CEILING PANELS COOLER B.O. PANELS 8' - 4 " [ 1 0 0 . 0 0 0 0 ] 2 Q-01 T 1'-1"1'-0" 11 " AI R AI R HEATCRAFT LEL0095AS6AMAB0200 AI R AI R HEATCRAFT LEL0095AS6AMAB0200 AI R AI R HEATCRAFT LEL0095AS6AMAB0200 4 3/8" 35°F Cold Vault QE093030-02 4" walls, 4" ceiling, floorless 124" high, foam rail, lag-down w/o fascia Int: Galvanized/Embossed White - 26 Ga. Ext: Galvanized/Embossed - 26 Ga. 35°F Cooler QE093030-02 4" walls, 4" ceiling, floorless 100" high, foam rail, lag-down w/o fascia Ext: Galvanized/Embossed - 26 Ga. Walls int: Galvanized/Embossed - 26 Ga. Ceiling int: Galvanized/Embossed White - 26 Ga. 4'-5" 9 1/8" 2 Room 1 of 2 Room 2 of 2 10 7/8" LEC0130AS7AMAB0200 1 1 1 1 1 1 INSULATED WALL PANEL SEALANT (INCLUDED) WALL NO FLOOR PVC "U" SHAPED NON-LOCKING SCREED FOAM RAIL VINYL "U" SHAPED FLOOR SCREED (NON-LOCKABLE) DRIVE PINS (NOT INCLUDED) SECTION @ COMMON WALL WITH MULTIPLE HEIGHT CEILINGS - LOCK DOWN FOAM RAIL 1/ 2 " KE R F CU T 1/ 2 " KE R F CU T PROVIDE KERF CUT 1/2" FROM RAIL EDGE FOR WALL METAL CENTER OF CEILING X'-XX" ABOVE BOTTOM OF WALL PANEL INSULATED CEILING PANEL INSULATED WALL PANEL CAM-LOCK CEILING TO WALLS LAG DOWN - NON FASCIA (FIELD INSTALLED CAPS) FOAM RAIL FIELD INSTALLED TRIM CAP (STD.) HEX HEAD SCREWS INSULATED WALL PANEL INSULATED CEILING PANEL 3/8" LAG BOLT W/ WASHER 5/8" BLOCKING LAG DOWN - HEADER BRACE BRACKET (FIELD INSTALLED CAPS) FOAM RAIL DRYWALL SCREW @ FRAMING (2) INSULATED HEADER PANEL HEADER BRACE BRACKET INSULATED CEILING PANEL 3/8" LAG BOLT W/ WASHER FIELD INSTALLED TRIM CAP HEX HEAD SCREWS 5/8" BLOCKING CEILING SUPPORT BRACKET FOAM RAIL STEEL PLATE, NUTS AND WASHERS (OPTION) ROD - ALL-THREAD (OPTION) SLOTTED HANGER BRACKET BY PANEL MANUFACTURER (STANDARD) NON SECURING NAIL TO HOLD BRACKET TO TONGUE PRIOR TO CAM-LOCKED IN PLACE INSULATED CEILING PANEL DETAIL @ FLUSH DOOR WITH THRESHOLD INSULATED DOOR PANEL CONCRETE SLAB ADJUSTABLE DOOR SWEEP THRESHOLD NEOPRENE WIPERS EXTERIORINTERIOR 3/ 4 " REV DATE BYDESCRIPTION ·ALL ELECTRICAL COMPONENTS WITHIN THE WALK-INS. I.E. PRESSURE RELIEF PORTS, JAMB HEATERS SHALL BE FACTORY PRE-WIRED, FOR HOOK UP BY ELECTRICAL CONTRACTOR. ·ALL LIGHT FIXTURES SUPPLIED ARE SHIPPED LOOSE FOR INSTALLATIONS BY ELECTRICAL CONTRACTOR. ·CrownTonka SHALL ACCEPT NO RESPONSIBILITY FOR ANY BACK CHARGES ASSOCIATED WITH INSTALLATION OF LIGHT FIXTURES OR FIELD WIRING CONNECTIONS. ELECTRICAL NOTICE REFERENCE SYMBOL LEGEND T-MOLDING (Opening Finish) DAIRY LIP (Opening Finish) JAMB GUARDS (Opening Finish) TM ELEVATION REF. DWG NUMBER SECTION REF. DWG NUMBER DETAIL REF. DWG NUMBER KEY NOTE DOOR TAG DATUM POINT DL JG REVISION NUMBERX X X X X X X X X X DXX COMPLIANCE WALK-INS MEET OR EXCEED ALL PRESCRIPTIVE STANDARDS OF THE ENERGY INDEPENDENCE AND SECURITY ACT (EISA) OF 2007 CONSTRUCTION (STANDARD) ·CORNERS AND T-WALLS TO BE ONE PIECE CONSTRUCTION W/ 3/8" RADIUS AT ALL INSIDE VERTICAL CORNERS, JOINTS SEALED W/ PVC GASKET AT INT. & EXT. PERIMETER OF PANELS, CONNECTED W/ CAM-LOCK FASTENERS. ·ALL CEILING AND WALL PANELS ARE NOT DESIGNED TO CARRY ADDITIONAL CONDENSING UNIT WEIGHT UNLESS SPECIFICALLY NOTED OTHERWISE AND DESIGNATED IN PLAN ·TO AVOID DOOR GASKET DAMAGE: DO NOT ENERGIZE FREEZER DOOR HEATERS PRIOR TO STARTUP OF REFRIGERATION ·TO AVOID DISCOLORATION OF METAL ON PANELS: PROPERLY VENTILATE EACH ROOM IF TILE OR MASONRY WORK IS TO BE DONE WARNINGS: SITE NOTATION ·WHEN APPLICABLE - DOES BUILDING FLOOR HAVE TILE AND GROUT INSTALLED BEFORE OR AFTER WALK-IN INSTALLATION IF SO PROVIDE TILE THICKNESS _______ ·ALLOW 2" FOR COOLER AND FREEZER MINIMUM AIR SPACE ALL AROUND WALK-IN FOR AMPLE AIR CIRCULATION APPROVAL INITIALS: 3 Q-01 ELEVATION 1/4" = 1'-0" *FOR APPROVAL ONLY* APPROVAL INITIALS: 1 Q-01 WALL PANEL/CEILING PANEL PLAN 1/4" = 1'-0" ·SLAB / PAD MUST BE LEVEL WITHIN 1/4" OVER 10'-0" IN ANY DIRECTION. ·SLAB / PAD MUST BE FLAT, SMOOTH, AND UNIFORM WITH MAXIMUM 1/4" TOTAL DEVIATION OVER 10'-0" STRAIGHTEDGE IN ANY DIRECTION. CONCRETE SLAB / PAD NOTICE X I HEREBY ACKNOWLEDGE THAT I HAVE BEEN INFORMED OF THE ABOVE SLAB / PAD REQUIREMENTS AND FAILURE TO COMPLY WILL RESULT IN REFUSAL TO INSTALL AND/OR WILL VOID ANY WARRANTY COVERAGE FOR ISSUES ON THIS WALK-IN RESULTING FROM SUCH INSTALLATION. KEY NOTESX APPROVAL INITIALS: APPROVAL INITIALS:BOX DESCRIPTION REFRIGERATION APPROVAL INITIALS: *REFRIGERATION ON PLAN VIEW IS NOT FOR INSTALLATION PURPOSES - INSTALLATION TO BE BY REFRIGERATION CONTRACTOR* 1.PRESSURE RELIEF VENT: KASON 1836 (NON - HEATED) - TYPICAL 2.LIGHT LED 45W 48" EVERIDGE - TYPICAL APPROVAL INITIALS: 2 Q-01 ELEVATION 1/4" = 1'-0" ULNSF® 15600 37TH AVE N. SUITE 100 PLYMOUTH, MN 55446 PHONE (763) 541-1410 FAX (763) 541-1563 Site Information Customer Service Rep. Submittal Drafter Shop Drafter Create Dwg Date: Customer/Dealer Save Dwg Date: Drawing Reviewed By: Review Date: Approved as Drawn: Revise and Resubmit: Please Check Appropriate Field Approval Status Block CLA S S I F I ED ® Project # Sheet # JOSH DORAN SD 08/13/2025 CIRCLE K-WEST COAST (CA,OR,WA) 495 E RINCON ST 150 CORONA, CA 92879 CIRCLE K - 9269 - NWC YELM AVE. & KILLON RD. YELM, WA 98597 08/13/2025 E093030-02 Q-01 1 - COMPARTMENT HEIGHT UPDATED. 10 . 0 3 . 2 0 2 5 SD INSULATED WALL PANEL POWER SUPPLY & FIELD WIRING BY ELECTRICIAN INSULATED CEILING PANEL 6" AP P R O X . ℄ PILOT LIGHT SWITCH - STUB OUT THRU WALL PILOT LIGHT SWITCH INTERIOR 48" A.F.F. ℄ 1/2" CONDUIT FOR U.S.A. 3/4" CONDUIT FOR CANADA BLACKHOT WHITENEUTRAL REDLOAD/LIGHTS GREENGROUND CUSTOMER CONNECTIONS 4" x 4" JUNCTION BOX STUB OUT THROUGH INT PILOT LIGHT SWITCH WIRING (SINGLE POLE SWITCHING) FRONT VIEW RE D ( L O A D ) GREEN (GND) WHITE (NEUTRAL) BLACK (LINE) FROM SUPPLY TO LIGHTS WH I T E ( N E U T R A L ) EVERIDGE 4' LED LIGHT FIXTURE - STUB THRU INTERIOR CONDUIT FOR 120V POWER TO LIGHT FIXTURE( BY OTHERS) VAPOR PROOF LIGHT FIXTURE FROM SWITCH RE D ( L O A D ) WH I T E ( N E U T R A L ) INSULATED CEILING PANEL JUNCTION BOX LN ELECTRICAL INFORMATION ITEM DESCRIPTION QTY.VOLTAGE (V) (EA) AMPS (A) (EA) EVERIDGE 4' LED LIGHT (45W)10 120 0.38 REV DATE BYDESCRIPTION ·ALL ELECTRICAL COMPONENTS WITHIN THE WALK-INS. I.E. PRESSURE RELIEF PORTS, JAMB HEATERS SHALL BE FACTORY PRE-WIRED, FOR HOOK UP BY ELECTRICAL CONTRACTOR. ·ALL LIGHT FIXTURES SUPPLIED ARE SHIPPED LOOSE FOR INSTALLATIONS BY ELECTRICAL CONTRACTOR. ·CrownTonka SHALL ACCEPT NO RESPONSIBILITY FOR ANY BACK CHARGES ASSOCIATED WITH INSTALLATION OF LIGHT FIXTURES OR FIELD WIRING CONNECTIONS. ELECTRICAL NOTICE COMPLIANCE WALK-INS MEET OR EXCEED ALL PRESCRIPTIVE STANDARDS OF THE ENERGY INDEPENDENCE AND SECURITY ACT (EISA) OF 2007 CONSTRUCTION (STANDARD) ·CORNERS AND T-WALLS TO BE ONE PIECE CONSTRUCTION W/ 3/8" RADIUS AT ALL INSIDE VERTICAL CORNERS, JOINTS SEALED W/ PVC GASKET AT INT. & EXT. PERIMETER OF PANELS, CONNECTED W/ CAM-LOCK FASTENERS. ·ALL CEILING AND WALL PANELS ARE NOT DESIGNED TO CARRY ADDITIONAL CONDENSING UNIT WEIGHT UNLESS SPECIFICALLY NOTED OTHERWISE AND DESIGNATED IN PLAN ·TO AVOID DOOR GASKET DAMAGE: DO NOT ENERGIZE FREEZER DOOR HEATERS PRIOR TO STARTUP OF REFRIGERATION ·TO AVOID DISCOLORATION OF METAL ON PANELS: PROPERLY VENTILATE EACH ROOM IF TILE OR MASONRY WORK IS TO BE DONE WARNINGS: SITE NOTATION ·WHEN APPLICABLE - DOES BUILDING FLOOR HAVE TILE AND GROUT INSTALLED BEFORE OR AFTER WALK-IN INSTALLATION IF SO PROVIDE TILE THICKNESS _______ ·ALLOW 2" FOR COOLER AND FREEZER MINIMUM AIR SPACE ALL AROUND WALK-IN FOR AMPLE AIR CIRCULATION *FOR APPROVAL ONLY* ·SLAB / PAD MUST BE LEVEL WITHIN 1/4" OVER 10'-0" IN ANY DIRECTION. ·SLAB / PAD MUST BE FLAT, SMOOTH, AND UNIFORM WITH MAXIMUM 1/4" TOTAL DEVIATION OVER 10'-0" STRAIGHTEDGE IN ANY DIRECTION. CONCRETE SLAB / PAD NOTICE X I HEREBY ACKNOWLEDGE THAT I HAVE BEEN INFORMED OF THE ABOVE SLAB / PAD REQUIREMENTS AND FAILURE TO COMPLY WILL RESULT IN REFUSAL TO INSTALL AND/OR WILL VOID ANY WARRANTY COVERAGE FOR ISSUES ON THIS WALK-IN RESULTING FROM SUCH INSTALLATION. NOTE: REFRIGERATION AND LIGHTING TO FOLLOW IFC PERMITTING PLAN ULNSF® 15600 37TH AVE N. SUITE 100 PLYMOUTH, MN 55446 PHONE (763) 541-1410 FAX (763) 541-1563 Site Information Customer Service Rep. Submittal Drafter Shop Drafter Create Dwg Date: Customer/Dealer Save Dwg Date: Drawing Reviewed By: Review Date: Approved as Drawn: Revise and Resubmit: Please Check Appropriate Field Approval Status Block CLA S S I F I ED ® Project # Sheet # JOSH DORAN SD 08/13/2025 CIRCLE K-WEST COAST (CA,OR,WA) 495 E RINCON ST 150 CORONA, CA 92879 CIRCLE K - 9269 - NWC YELM AVE. & KILLON RD. YELM, WA 98597 08/13/2025 E093030-02 QE-01 1 - COMPARTMENT HEIGHT UPDATED. 10 . 0 3 . 2 0 2 5 SD