HomeMy WebLinkAboutJB2103278_Yelm_Site Plan Revision (23728)PROJECT FOOTAGES NEW AERIAL: 314' NEW UNDERGROUND: 0 EXISTING AERIAL/OVERLASH: 0 EXISTING UNDERGROUND: 1,314' TOTAL FOOTAGE: 1,628' OWNER / APPLICANT COMCAST CONTACT: BRIAN HOBACK; NETWORK PROJECT MANAGER MOBILE: (253) 254-1366 EMAIL: BRIAN_HOBACK@COMCAST.COM MICHAELS LANDING PROJECT #: 2103278 16803 CANAL RD SE YELM, WA 98597 DESIGN BY K&B TECHNICAL SOLUTIONS P.O. BOX 2529 CLACKAMAS, OR 97015 CONTACT: BRAD ROLLINS MOBILE: (281) 923-8353 EMAIL: PERMITS@KBMAIL.NET riayywwm V 0 Baseball Field Bathroom (D Longmire Community Park N WE w U) oLO �00 Z UNIT CODES Q FOR INTERNAL USE CO U _j O J 00 W O } SHEETINDEX SHT DESCRIPTION CS COVER SHEET/VICINITY MAP 1 RIGHT-OF-WAY PLAN L LEGEND & TYPICALS ATTENTION: WASHINGTON LAW REQUIRES AN EXCAVATOR TO PROVIDE , THE NOTICE TO A ONE -NUMBER LOCATOR SERVICE NOT LESS THAN TWO BUSINESS DAYS AND NOT MORE THAN , TEN BUSINESS DAYS BEFORE THE SCHEDULED DATE FOR COMMENCEMENT OF EXCAVATION, UNLESS OTHERWISE AGREED BY THE EXCAVATOR AND FACILITY OPERATORS. IF AN EXCAVATOR INTENDS TO WORK AT MULTIPLE SITES OR AT A LARGE PROJECT, THE EXCAVATOR MUST TAKE REASONABLE STEPS TO CONFER WITH FACILITY OPERATORS TO ENABLE THEM TO LOCATE UNDERGROUND Know FACILITIES REASONABLY IN ADVANCE OF THE START OF EXCAVATION FOR EACH PHASE OF THE WORK. what's below. Call before you dig, Z Q J d Q �� CV 2 M (� _O N � J W IL 0 i U WEEo o E , �2 0 r` M W LO M Z O O N C J Ern a O . m E r1% U N y J U U n z N— E _ LO O W N of O o m m CO O a 0 m m N o p U Q 2 M O U d L,t, E Y N O O M @ In Y z �� , N O U i C 9 C U=m M m SHEET CS PROJECT ID CM EX-52133-23728 N W E � 16713 S 0 50' 100' SCALE: 1 "=100' a / / POLE #559563-1478 Pole Owner: PSE Pole #1: 559563-147899 Current Height Violation (Y/N) Make -Ready Secondary 25' 3" N N Pwr Sec LOOP 24' 4" N N Comcast 21' 11" Y Y Proposed Height Comcast-Over lash 20' 7" 16713 Pole Owner: PSE Pole #2: 559538-147919 Current Height Violation (Y/N) Make -Ready Neutral 26' 1" N N Secondary 26' 1" N N Pwr Sec LOOP 24' 0" N N Comcast 22' 3" Y Y Proposed Height Comcast-Over lash 20' 8" Comcast-New 20' 2" DEVELOPER TO PLACE (1)-2" CONDUIT IN OPEN TRENCH ON BEHALF OF COMCAST COMCAST TO PULL NEW (1)-0.625 COAX CABLE THROUGH NEW CONDUIT (TYPICAL) PLACE NEW PEDESTAL IN PUBLIC UTILITY EASEMENT \ (TYPICAL) 5 \ 6 QJ4, 1ry'1. �O. 7 I I 1. ALL WORK AREAS TO BE RESTORED TO LIKE OR BETTER CONDITION. 2. UNDERGROUND UTILITIES HAVE BEEN PLOTTED FROM AVAILABLE RECORDS AND FIELD OBSERVATIONS BUT ARE NOT NECESSARILY EXACT. 4TTENTION: Washington law requires an excavator to provide the notice to a one -number locator service not less than two business 3. IT IS THE CONSTRUCTION CONTRACTOR'S RESPONSIBILITY TO FIELD days and not more than ten business days before the scheduled date for commencement of excavation, unless otherwise agreed LOCATE ALL UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION. by the excavator and facility operators. If an excavator intends to COMPLETE REPAIR OF ANY AND ALL DAMAGES INCURRED SHALL BE AT THE work at multiple sites or at a large project, the excavator must take EXPENSE OF THE CONTRACTOR. seasonable steps to confer with facility operators to enable them to locate underground facilities reasonably in advance of the start of excavation for each phase of the work. J 16722 TIE-IN AT EXISTING UTILITY POLE A" POLE #559538-147919 OVERLASH NEW (1)-0.625 COAX CABLE / TO EXISTING CABLE/STRAND 106 po PLACE (1)-2" CONDUIT RISER ON EXISTING UTILITY POLE PULL NEW (1) 0.625 COAX CABLE THROUGH NEW CONDUIT 106 1 15 / c 2 3 / 14 4 Rio 13 / /QJ OPQ, 12 10 9 8 20000 16843 / 16816 16844 / 16848 GROVE RD SE 16815 —MOM 0/. 16919 �\ LLI W 0 u7 00 J O Q Q Z Q M O LLI O }, O Z Q J d Q ILL O O ' cV 2 M (� _O N � J LU i IL O U WEE6 ° `v u2 0 r_ M rnLO z O� co O � N C J E rn a O Y m E fn U N N y J U U r V C . Z N — E _ Lr) O N W N of Q o m mm O a SHEET 1 PROJECT ID CM EX-52133-23728 LINETYPES AERIAL CABLE EXISTING CONDUIT NEW CONDUIT ------------------- RIGHT-OF-WAY EASEMENT ESMT PUBLIC UTILITY EASEMENT PUE PROPERTY LINE — CENTERLINE FACE OF CURB FOC EDGE OF PAVEMENT EOP EDGE OF CONCRETE EOC EDGE OF GRAVEL EOG EDGE OF SIDEWALK S/w EXCAVATION LIMITS ----------- SEWER s STORM —SD— WATER W GAS G POWER P TELEPHONE T FIBER OPTIC FO CATV CATV TRAFFIC SIGNAL TRS STREET LIGHT SLT FENCE LINE GUARD RAIL RAILROAD TRACKS BUILDING FOOTPRINT SYMBOLS JOINT USE POLE ® POLE TAG JOINT USE POLE W/ TRANSFORMER ® POLE TAG POWER POLE W/ TRANSFORMER ® POLE TAG POWER POLE X POLE TAG CABLE POLE 0 POLE TAG TELEPHONE POLE Q POLE TAG EXISTING CONDUIT RISER S PROPOSED CONDUIT RISER S* EXISTING PEDESTAL EXISTING VAULT/HANDHOLE Ell EXISTING MANHOLE vd) PROPOSED PEDESTAL _I PROPOSED VAULT/HANDHOLE PROPOSED MANHOLE INLET 0 VALVE N METER FE HYDRANT Z7 POWER TRANSFORMER STREET LIGHT POLE TRAFFIC SIGNAL POLE SIGNAL CONTROLLER CROSS WALK SIGNAL O RAILROAD SIGNAL �o TREE CULVERT EXISTING SPLICE CASE PROPOSED SPLICE CASE Z Q J d Lu >Q> U) � o LL Ln �0) ooO Q >Q cV 2 Q > O U N M } 00 W IL 0 i F- U z � a z 2 w U U 0 0 0 U 'z z w U w O N — Z O d m d C U z > Y 0 U m m O z 0 Lu w 0 w a o �2 0 n M W Lo M Z O W 0 N C J E 0) a O Y m E fn U N y J co U U N Z N — E _ Lo O W N a Q o comm O a m m N O c Q 2 M O U a O � N U 0 M ell In o N Z � N O O U U C U°- =m c m SHEET L PROJECTID CM EX-52133-23728