Loading...
HomeMy WebLinkAboutDawn Fox - Yelm, WARev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" PV 0.0 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 SHEET INDEX: GENERAL NOTES AND PROJECT DATA SCALE: NTS 2 SATELLITE VIEW PV 0.0 SCALE: NTS 3 VICINITY MAP PV 0.0 PHOTOVOLTAIC ROOF MOUNT SYSTEM 18 MODULES-ROOF MOUNTED - 7.380 kW DC, 7.680 kW AC, 15812 90TH AVE SE, YELM, WA 98597 SYSTEM SIZE: 7.380 KW DC 7.680 KW AC MODULE TYPE & AMOUNT:(18) ZNSHINESOLAR ZXM7-SH108-410M MODULE DIMENSIONS:(L/W/H) 67.87"/44.64"/1.8" INVERTER: (10) AP SYSTEMS DS3-L [240V] INTERCONNECTION METHOD: LOAD BREAKER AHJ: CITY OF YELM PHOTOVOLTAIC SYSTEM SPECIFICATIONS:SITE DETAIL: 1 GENERAL NOTES AND PROJECT DATA PV 0.0 RACKING:CHIKO RACKING SYSTEM FOR COMP ROOF ARRAY AREA: 21.04 SQFT x 18 = 378.7 SQFT UTILITY: PSE MSP: EXISTING 200A MSP WITH 200A MAIN BREAKER ROOF MATERIAL:COMPOSITE SHINGLE ASCE 7-10 WINDSPEEDS: (3 SEC GUST IN MPH) RISK CATEGORY II: 110 MPH PV 0.0: GENERAL NOTES AND PROJECT DATA PV 1.0: PLOT PLAN PV 1.1: SITE PLAN PV 1.2: ROOF SECTION IM 1.0: INVERTER MAP S 1.1: MOUNT DETAILS E 1.1: 3-LINE DIAGRAM E 1.2: NOTES E 1.3: WARNING LABELS DS 01: PV MODULE SPECIFICATION SHEET DS 02: MICROINVERTER SPECIFICATION SHEET DS 03: COMBINER PANEL CERTIFICATION DS 04: AC DISCONNECT UL CERTIFICATION DS 05: JUNCTION BOX UL CERTIFICATION DS 06: WIRING SPECIFICATION DS 07: MOUNTING - DATA SHEET DS 08: RACKING - DATA SHEET DS 09: SPLICE KIT-DATA SHEET DS 10: GROUNDING - DATA SHEET DS 11: MID CLAMP - DATA SHEET DS 12: END CLAMP - DATA SHEET DS 13: CHIKO USA UL LISTING CERTIFICATE DS 14: SITE SAFETY MAP PHOTOVOLTAIC NOTES: 1. AN INVERTER OR AN AC MODULE IN AN INTERACTIVE PHOTOVOLTAIC SYSTEM SHALL AUTOMATIC ALL DE-ENERGIZE ITS OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS OF VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED. (NEC 690361) 2. ALL EXTERIOR ELECTRICAL METALLIC TUBING(EMT) CONDUIT FITTING SHALL BE RAIN TIGHT THREAD-LESS COMPRESSION TYPE. 3. MODULES AND SUPPORT STRUCTURES SHALL BE GROUNDED 4. NAMEPLATES SHALL BE PROVIDED FOR ALL CIRCUITS IN THE SERVICE DISTRIBUTION AND POWER DISTRIBUTION SWITCH BOARDS, PANEL BOARDS, DISCONNECTING SWITCHES, TERMINAL CABINETS, ETC.ALL NAMEPLATES SHALL BE PERMANENTLY ATTACHED AND BE OF SUFFICIENT CAPACITY TO WITHSTAND THE WEATHER. 5. JUNCTION BOX/COMBINER BOX HAVE TO USE COMPRESSION TYPE STRAIN RELIEF POSITIONED FOR APPROPRIATE WATER RUN OFF. 6. CONDUIT RUNS SHALL BE PROVIDED WITH SUFFICIENT WEATHERPROOF PULL BOXES OF JUNCTION BOX/COMBINER BOXES PER APPROPRIATE NEC REQUIREMENTS. 7. SEE PROVIDED CUT SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS 8. WIRING MATERIALS SHALL BE SUITABLE FOR THE SUN EXPOSURE AND WET LOCATIONS. FIELD APPLIED PROTECTIVE COATINGS ARE NOT ACCEPTABLE. 9. JUNCTION, PULL AND OUTLET BOXES LOCATED BEHIND MODULES SHALL BE SO INSTALLED THAT THE WIRING CONTAINED IN THEM CAN BE RENDERED ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF MODULE(S) SECURED BY REMOVABLE FASTENERS AND CONNECTED BY A FLEXIBLE WIRING SYSTEM. (NEC 690.34) 10. IN AN UNDERGROUND PHOTOVOLTAIC SYSTEM, THE POWER SOURCE SHALL BE LABELED WITH THE FOLLOWING WARNING AT EACH JUNCTION BOX, COMBINER BOX, DISCONNECT AND DEVICE WHERE THE UNGROUNDED CIRCUITS MAY BE EXPOSED DURING SERVICE : " WARNING - ELECTRIC SHOCK HAZARD. THE CURRENT CIRCUIT CONDUCTORS OF THIS PHOTOVOLTAIC POWER SYSTEM ARE UNGROUNDED BUT MAY BE ENERGIZED WITH THE RESPECT TO GROUND DUE TO LEAKAGE PATHS AND/OR GROUND (NECE 690.35(F)) 11. ALL PHOTOVOLTAIC MODULES AND ASSOCIATED EQUIPMENT AND WIRING MATERIAL SHALL BE PROTECTED FROM ANY PHYSICAL DAMAGE. 12. ALL ELECTRICAL DEVICES AND UTILIZATION EQUIPMENT SHALL BE LISTED BY AN APPROVED TESTING AGENCY. 13. OUTDOOR EQUIPMENT SHALL BE AT LEAST NEMA 3R RATED. 14. ALL SPECIFIED WIRING IS BASED ON THE USE OF COPPER 15. CONTRACTOR SHALL OBTAIN ELECTRICAL PERMITS AND SHALL COORDINATE ALL INSPECTION, COMMISSIONING AND ACCEPTANCE WITH THE CLIENT, UTILITY CO. AND CITY INSPECTORS AS NEEDED 16. DRAWINGS ARE DIAGRAMMATIC ONLY, ROUTING OF RACEWAYS SHALL BE AT THE OPTION OF THE CONTRACTOR UNLESS OTHERWISE NOTED AND SHALL BE COORDINATED WITH OTHER TRADES. 17. IF DISTANCES OF CABLE RUNS ARE DIFFERENT THAN SHOWN, THE CONTRACTOR SHALL NOTIFY ELECTRICAL ENGINEER TO VALIDATE THE WIRE SIZE. FINAL DRAWINGS WILL BE RED-LINED AND UPDATED AS APPROPRIATE. 18. WHENEVER A DISCREPANCY IN QUANTITY OF EQUIPMENT, ARISES ON THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICES REQUIRED BY THE STRICTEST CONDITIONS NOTED ON THE DRAWINGS OR IN THE SPECIFICATIONS TO ENDURE COMPLETE COMPLIANCE AND LONGEVITY OF THE OPERABLE SYSTEM REQUIRED BY THE ARCHITECT/ENGINEER. 19. ALL BROCHURES, OPERATION MANUALS, CATALOGS, SHOP DRAWINGS, ETC. SHALL BE HANDED OVER TO THE OWNER'S REPRESENTATIVE AT THE COMPLETION OR WORK. 20. ALL WIRING CONCEALED IN WALL AND CEILING SPACES SHALL BE IN METAL CONDUIT. 21. THE SEISMIC BRACING AND ANCHORAGE OF ELECTRICAL CONDUITS SHALL BE IN ACCORDANCE WITH THE "SMACNA"-GUIDLINES FOR SEISMIC RESTRAINS OF MECHANICAL SYSTEMS AND PLUMING PIPING SYSTEMS. 22. ALL OF THE LISTED SYSTEMS REQUIRED THAT THE SEISMIC LATERAL FORCE F INCLUDING CONSIDERATION OF a^P AND r^P BE DETERMINED AT EACH LEVEL OF THE BUILDING SO THAT BRACE SPACING CAN BE CALCULATED. THE DISTRICT STRUCTURAL ENGINEER CAN APPROVE THE SEISMIC LATERAL FORCE DETERMINATION. 23. A COPY OF THE CHOSEN BRACING SYSTEM(S) INSTALLATION GUIDE/MANUAL SHALL BE ON THE JOB SITE PRIOR TO STARTING THE INSTALLING OF HANGERS AND/OR BRACES. 24. WHEN INSTALLING DRILLED-IN ANCHORS AND/OR POWDER DRIVEN PINS IN EXISTING NON-PRESTRESSED REINFORCED CONCRETE, USE CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE REINFORCED BARS . WHEN INSTALLING THEM INTO EXISTING PRE-STRESSED CONCRETE TENDONS BY USING A NON-DESTRUCTIVE METHOD PRIOR TO INSTALLATION. EXERCISE EXTREME CARE AND CAUTION TO AVOID CUTTING OR DAMAGING THE TENDONS DURING INSTALLATION. MAINTAIN A MINIMUM CLEARANCE OF ONE INCH BETWEEN THE REINFORCEMENT AND THE DRILLED-IN ANCHOR. 25. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. 26. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT. (NEC 300.6 01, 310.8 D) 27. GROUNDING BUSHINGS ARE REQUIRED AROUND PRE-PUNCHED CONCENTRIC KNOCKOUTS ON THE DC SIDE OF THE SYSTEM. (NEC 250.97) 28. THE GROUNDING ELECTRODE CONDUCTOR MUST BE PROTECTED FROM PHYSICAL DAMAGE IF SMALLER THAN #6 COPPER WIRE. (NEC 250.64 B) 29. GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT. (NEC 250.64 C) 30. RACEWAY FOR GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END. 31. WHERE ALL TERMINALS OF THE DISCONNECTING MEANS MAY BE ENERGIZED IN THE OPEN POSITION, A SIGN WILL BE PROVIDED WARNING OF THE HAZARD PER NEC 690.17. 34. EACH UNGROUNDED CONDUCTOR OF THE MULT-IWIRE BRANCH CIRCUIT WILL BE IDENTIFIED PER PHASE AND SYSTEM PER NEC210.5. 32. CIRCUITS OVER 250V TO GROUND SHALL COMPLY WITH NEC250.97 & 250.92 (B) 33. DC CONDUCTORS EITHER DO NOT ENTER THE BUILDING OR ARE RUN IN METALLIC RACEWAYS OR ENCLOSURES TO THE FIRST ACCESSIBLE DC DISCONNECTING MEANS PER NEC 690.31 (E) 34. ALL METALLIC FRAME RAILS AND OTHER CURRENT CARRYING METALLIC COMPONENTS (CONDUIT, JUNCTION & PULL BOXES, RACEWAY, ETC) SHALL BE SOLIDLY GROUNDED PER THE MANUFACTURER'S INSTALLATION INSTRUCTIONS 35. SCREWS, NUTS, BOLTS & WASHERS THAT ATTACH EQUIPMENT GROUNDING LUGS SHALL BE STAINLESS STEEL 36. NO PIPING, DUCTS OR EQUIPMENT FOREIGN TO ELECTRICAL EQUIPMENT SHALL BE PERMITTED TO BE LOCATED WITHIN THE DEDICATED SPACE ABOVE THE ELECTRICAL EQUIPMENT. 37. ALL FIELD INSTALLED JUNCTION, PULL AND OUTLET BOXED LOCATED BEHIND MODULES OR PANELS SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE (S) OR PANEL (S) SECURED BY REMOVABLE FASTENERS. 38. REMOVAL OF A DWP-INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT DISCONNECT THE BONDING CONNECTION BETWEEN THE GROUNDING ELECTRODE CONDUCTOR AND THE PHOTOVOLTAIC SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR. 39. THE ROOF MOUNTED PHOTOVOLTAIC MODULES, PANELS, OR SOLAR VOLTAIC ROLL ROOFING MATERIAL SHALL HAVE THE SAME OR BETTER LISTED FIRE-RESISTANCE RATING THAN THE BUILDING ROOF-COVERING MATERIAL. 40. ALL ROOF MOUNTED CONDUIT WILL BE A MINIMUM 1/2" OFF THE ROOF SURFACE. 130'-4" 60 ' - 1 1 " 132'-9" 61 ' - 2 " 25'-0" 4' - 1 " 5' - 4 " 59'-6" N Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" PV 1.0 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 PLOT PLAN SCALE: 3/32" = 1'-0" 1 PLOT PLAN PV 1.0 PHOTOVOLTAIC ROOF MOUNT SYSTEM 18 MODULES-ROOF MOUNTED - 7.380 kW DC, 7.680 kW AC, 15812 90TH AVE SE, YELM, WA 98597 SYSTEM SIZE: 7.380 kW DC 7.680 kW AC MODULE TYPE & AMOUNT:(18) ZNSHINESOLAR ZXM7-SH108-410M MODULE DIMENSIONS:(L/W/H) 67.87"/44.64"/1.8" INVERTER:(10) AP SYSTEMS DS3-L [240V] AHJ: CITY OF YELM PHOTOVOLTAIC SYSTEM SPECIFICATIONS: ROOF #1 (10) ZNSHINESOLAR ZXM7-SH108-410M SLOPE: 29° AZIM.: 180° ROOF ACCESS POINT M FENCE EXISTING INTERIOR MAIN SERVICE PANEL TIED TO EXTERIOR UTILITY METER #163 579 186 ROOF #2 (08) ZNSHINESOLAR ZXM7-SH108-410M SLOPE: 29° AZIM.: 180° GOVERNING CODES: ·2021 WASHINGTON STATE BUILDING CODE ·2021 WASHINGTON STATE RESIDENTIAL CODE ·2021 WASHINGTON STATE MECHANICAL CODE ·2021 WASHINGTON STATE FIRE CODE ·2021 UNIFORM WASHINGTON STATE PLUMBING CODE ·2021 WASHINGTON STATE ENERGY CODE ·2021 WASHINGTON STATE EXISTING BUILDING CODE ·2023 NATIONAL ELECTRICAL CODE NEW PV AC DISCONNECT VISIBLE, LOCKABLE, LABELED DISCONNECT WITHIN 10' OF UTILITY METER TREE TYP. PROPERTY LINE PR O P E R T Y L I N E PROPERTY LINE PR O P E R T Y L I N E FR O N T O F H O U S E 15 8 1 2 9 0 T H A V E S E DRIVEWAY MAIN HOUSE GARAGE DECKDECK ROOF ACCESS POINT ROOF ACCESS POINT SHALL NOT BE LOCATED IN AREAS THAT REQUIRE THE PLACEMENT OF GROUND LADDERS OVER OPENINGS SUCH AS WINDOWS OR DOORS, AND LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS WHERE THE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES OR SIGNS. NOTE : "PV SYSTEM SHALL HAVE THE SAME FIRE CLASSIFICATION AS THE ROOF ASSEMBLY" 5"22'-9"1'-5" 3'-1"29'-6"11" NEW PV ATTACHMENTS AT 4'-0" O.C. 11 ' - 6 " 12 ' - 8 " N Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" PV 1.1 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 SITE PLAN ROOF SECTIONS SCALE: 1/8" = 1'-0" 1 SITE PLAN PV 1.1 SYSTEM LEGEND = ATTACHMENT POINTS = RAFTER = ROOF OBSTRUCTIONS = FIRE PATHWAY = RACKING SYSTEM NEW VISIBLE, LOCKABLE, LABELED DISCONNECT LOCATED WITHIN 10' FROM THE UTILITY METER 18 NEW ZNSHINESOLAR ZXM7-SH108-410M MODULES WITH NEW (10) - AP SYSTEMS DS3-L [240V] INVERTERS. AC C NEW DEDICATED PV SYSTEM COMBINER PANEL. SYSTEM SIZE: 7.380 kW DC 7.680 kW AC MODULE TYPE & AMOUNT:(18) ZNSHINESOLAR ZXM7-SH108-410M MODULE DIMENSIONS:(L/W/H) 67.87"/44.64"/1.8" INVERTER:(10) AP SYSTEMS DS3-L [240V] AHJ: CITY OF YELM PHOTOVOLTAIC SYSTEM SPECIFICATIONS: MODULE - 08 SLOPE - 29° AZIMUTH - 180° MATERIAL - COMPOSITE SHINGLE TRUSS SIZE & SPACING - 2"X4" @ 24" O.C. MODULE - 10 SLOPE - 29° AZIMUTH - 180° MATERIAL - COMPOSITE SHINGLE TRUSS SIZE & SPACING - 2"X4" @ 24" O.C. ROOF #01 ROOF #02 = ATTIC RUN = CONDUIT ATTIC RUN JUNCTION BOX EXISTING INTERIOR MAIN SERVICE PANEL & POINT OF INTERCONNECTION. TIED TO EXTERIOR UTILITY METER #163 579 186. M BILL OF MATERIALS NUMBER OF MODULES 18 ZNSHINESOLAR ZXM7-SH108-410M NUMBER OF INVERTER 10 AP SYSTEMS DS3-L [240V] COMBINER PANEL 1 EATON BR STYLE 1-INCH LOAD CENTER 816L125RP AC DISCONNECT 1 60A NON FUSIBLE AC DISCONNECT, 240V NUMBER OF ATTACHMENTS 46 CHIKO AL ROOF HOOK #167 CK-FTS-167RT2 RAILS 10 CHIKO 518 RAIL 4200MM RAIL SPLICE 4 SPLICE KIT MID CLAMPS 26 MID CLAMPS / UFO END CLAMPS 20 END CLAMPS / STOPPER SLEEVE GROUNDING LUG 10 GROUNDING LUG MODULE, ARRAY WEIGHT (LOAD CALC'S) Number of Modules 18 Module Weight 45.19 LBS Total Module (Array) Weight 813.42 LBS Number of Attachment point 46 Mounting System Weight (Per Module)1.5 LBS Mounting System Weight 69.00 LBS Total System Weight (Module Weight + Mounting System Weight)882.42 LBS Weight at Each Attachment Point (Array Weight / Number of Attachment Point)17.68 LBS Module Area (67.87"x44.64")21.04 SqFt Total Array Area 378.71 SqFt Distributed Load (Total System Weight / Total Array Area)2.33 Per SqFt Total Roof Area 1921 SqFt Total Percentage or Roof Covered Total Array Area / Total Roof Area)*100 19.71% NOTE : ATTIC RUN - YES ATTIC FAN - NO SHUTDOWN - NO CIRCUIT #1 - 08 MODULES WITH 05 MICROINVERTERS CIRCUIT(S) NOTE : "PV SYSTEM SHALL HAVE THE SAME FIRE CLASSIFICATION AS THE ROOF ASSEMBLY" NOTE:(SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN) NEEDS TO BE LOCATED WITHIN 3FT OF AC DISCONNECT. NOTE : RACKING AND MOUNTING FEET ARE LISTED AND LABELED IN ACCORDANCE WITH UL 2703 AND IRC 324.3.1. VISIBLE, LOCKABLE, LABELED DISCONNECT WITHIN 10' OF UTILITY METER 15 8 1 2 9 0 T H A V E S E FR O N T O F H O U S E 18" FIRE SETBACK 18" FIRE SETBACK 36" FIRE SETBACK 36 " F I R E S E T B A C K 36" FIRE SETBACK 36 " F I R E S E T B A C K 36 " F I R E S E T B A C K ROOF #01 CIRCUIT #2 - 10 MODULES WITH 05 MICROINVERTERS M AC C NEW AC COMBINER PANEL NEW PV AC DISCONNECT GROUPED WITH SERVICE EQUIPMENT (VISIBLE, LOCKABLE, LABELED) EXISTING INTERIOR MAIN SERVICE PANEL & POINT OF INTERCONNECTION. TIED TO EXTERIOR UTILITY METER #163 579 186 ROOF #02 36" FIRE SETBACK 36" F I R E SET B A C K EXTERIOR BEARING WALL ROOF SECTION EXTERIOR BEARING WALL 3'-6" 6'-8" 5'-9" 8'-2" 3'-6" 6'-0" 6'-8" 5'-9" 8'-2"5'-10" 2" X 4" TRUSS @ 24" O.C.(N) PV MODULE 29.0° 6'-0"5'-10" Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" PV 1.2 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 ROOF SECTION 1 ROOF SECTION PV 1.2 ROOF-2 N Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" IM 1.0 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 INVERTER MAP 1 INVERTER MAP IM 1.0 1 13 2 14 3 15 4 16 5 17 6 18 7 19 8 20 9 21 10 22 11 23 12 24 DTU/ECU: Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" S 1.1 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 MOUNT DETAIL GENERAL STRUCTURAL NOTES: THE SOLAR PANELS ARE TO BE MOUNTED TO THE ROOF FRAMING USING THE CHIKO RACKING SYSTEM WITH CHIKO AL ROOF HOOK #167 CK-FTS-167RT2 ATTACHMENTS. THE MOUNTING FEET ARE TO BE SPACED AS SHOWN IN THE DETAILS, AND MUST BE STAGGERED TO ADJACENT FRAMING MEMBERS TO SPREAD OUT THE ADDITIONAL LOAD. 1.THE PROPOSED PV SYSTEM ADDS 2.33 PSF TO THE ROOF FRAMING SYSTEM. 2.ROOF LIVE LOAD = 20 PSF TYPICAL, 0 PSF UNDER NEW PV SYSTEM. 3.GROUND SNOW LOAD = 20 PSF 4.WIND SPEED = 110 MPH 5.EXPOSURE CATEGORY = B 6.RISK CATEGORY = II SCALE: NTS 2 ATTACHMENT DETAIL ENLARGED VIEW S 1.1 SCALE: NTS 1 ATTACHMENT DETAIL (SIDE VIEW) S 1.1 PV MODULE SEE (2/S 1.1) FOR ENLARGED VIEW SOLAR MODULE CHIKO 518 RAIL 4200MM CHIKO AL ROOF HOOK #167 CK-FTS-167RT2 CHIKO MID CLAMP / END CLAMP 2"X4" TRUSS @ 24" OC SUS304 FLANGE NUT M8 SUS304 T2 BOLT M8*30 (2) - WOODEN SCREW, M6.3 x 65. NOTE: - PER WAC 51-51-03240, PANELS WILL NOT MOUNT HIGHER THAN 18 INCHES ABOVE THE SURFACE OF THE ROOFTOP TO WHICH THEY ARE MOUNTED. 2"X4" TRUSS @ 24" OC 6" M A X (E) COMPOSITE SHINGLE ROOF NOTE : RACKING AND MOUNTING FEET ARE LISTED AND LABELED IN ACCORDANCE WITH UL 2703 AND IRC 324.3.1. MAX. DISTANCE B/W MOUNTING POINTS @ 48" MIN . 2 - 1 / 2 " EM B E D M E N T Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" E 1.1 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 3-LINE DIAGRAM Rooftop conductor ampacities designed in compliance with art. 690.8, Tables 310.15(B)(1), 310.15(C)(1), 310.15(B)(2), 310.16, Chapter 9 Table 4, 5, & 9. Location specific temperature obtained from ASHRAE 2017 data tables AMBIENT TEMP (HIGH TEMP 2%) RECORD LOW TEMP -10°C 29°C CONDUIT HEIGHT 7/8" ROOF TOP TEMP 51°C CONDUCTOR TEMPERATURE RATE 90°C THIS PANEL IS FED BY MULTIPLE SOURCES (UTILITY AND SOLAR) AC OUTPUT CURRENT NOMINAL AC VOLTAGE 240V 32A 120% RULE BUS BAR RATING X 120%) - MAIN BREAKER RATING =MAX. PV OCPD (200A x 120%) - 200 = 40A MICROINVERTERS SPECIFICATION MICROINVERTER MAKE MICROINVERTER MODEL NO. MAXIMUM AC OUTPUT MAX INPUT VOLTAGE MAX AC CURRENT AP SYSTEMS DS3-L 768 W 60 V 3.20 A MAX OUTPUT VOLTAGE 240 V G L1L1 L2L2 L2L2 L1L1 G (N) JUNCTION BOX 600 V, NEMA 4 UL LISTED 20A 20A (N) 125A COMBINER PANEL, 240V,3W,1-PHASE L1 L2 G 2 NOTE:(SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN) NEEDS TO BE LOCATED WITHIN 3FT OF AC DISCONNECT. VISIBLE, LOCKABLE, LABELED DISCONNECT WITHIN 10' OF UTILITY METER NOTE : ATTIC RUN - YES SHUTDOWN - NO PV MODULE RATING @ STC MANUFACTURER MAX. POWER-POINT CURRENT (IMP) MAX. POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) 13.10 AMPS 31.30 VOLTS 37.50 VOLTS 13.84 AMPS NOM. MAX. POWER AT STC (PMAX) MAX. SYSTEM VOLTAGE VOC TEMPERATURE COEFFICIENT 410 WATT 1500V -0.29 %/°C ZNSHINESOLAR ZXM7-SH108-410M 1 UTILITY SERVICE: UNDERGROUND WIRE TAG # CONT. CURR X 125% CONDUIT FILL: WIRE OCP TEMP DE-RATE: WIRE AMP:WIRE SIZE\TYPE\AMP. x x20A x x20A x x40A MAX PARALLEL DEVICES 1 2 3 C.C RATING PV CURR. MULT \ THWN \ #C.C.C.CONDUIT TRUNK CABLE IN AIR 3/4" FMC / NMC IN AIR @90°C40A#10 40A \ THWN \@90°C40A#10 40A \ THWN \@75°C50A#8 50A 2 1.00 4 0.80 2 1.00 DERATED AMPACITY 40.00A MAX. CONT. CURRENT GND #6 AWG #10 AWG #10 AWG TOTAL CURR LENGTH FT. MAX VOLTAGE DROP(%) 0.2820 55 1.19< 2 0.76 20.00A16.00A=x N/A05x3.20 1.00 1.00 1.00 =x N/A05x3.20 =x N/A10x3.20 20.00A16.00A 40.00A32.00A 0.15103/4" EMT 32.00A 50.00A 16.00A 16.00A 32.00A G G 200A M 40A/2P (E) LOADS EXISTING GROUNDING ELECTRODE SYSTEM EXISTING 240V/200A BUS BAR RATING, MAIN SERVICE PANEL, SINGLE PHASE, WITH A 200A MAIN BREAKER UTILITY COMPANY - PSE UTILITY METER# 163 579 186 (N) PV BREAKER POINT OF INTERCONNECT, LOAD SIDE 3 EXISTING BI-DIRECTIONAL UTILITY METER, 1-PHASE, 3W, 120V/240V 3 (N) BLADE TYPE NON-FUSIBLE AC DISCONNECT NEMA 3R 60A-2P 120/240VAC (VISIBLE, LOCKABLE, LABELED) MODULE:(18) ZNSHINESOLAR ZXM7-SH108-410M INVERTER:(10) AP SYSTEMS DS3-L [240V] BRANCH 1 - 08 MODULES WITH 05 MICRO INVERTERS (18) ZNSHINESOLAR ZXM7-SH108-410M (10) AP SYSTEMS DS3-L [240V] INVERTERS BRANCH 2 - 10 MODULES WITH 05 MICRO INVERTERS Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" E 1.2 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 NOTES SITE NOTES: 1.A LADDER WILL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. 2.THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. 3.THE SOLAR PV INSTALLATION WILL NOT OBSTRUCT ANY PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. 4.PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION NEC 110.26. 5.ROOF COVERINGS SHALL BE DESIGNED, INSTALLED, AND MAINTAINED IN ACCORDANCE WITH THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF COVERING SERVES TO PROTECT THE BUILDING OR STRUCTURE. EQUIPMENT LOCATIONS: 1.ALL EQUIPMENT SHALL MEET MINIMUM SETBACKS AS REQUIRED BY NEC 110.26. 2.WIRING SYSTEMS INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING TEMPERATURE AS SPECIFIED BY NEC 690.31 (A),(C) AND NEC TABLES 310.15 (B)(1) AND 310.15 (B)(2). 3.JUNCTION AND PULL BOXES PERMITTED INSTALLED UNDER PV MODULES ACCORDING TO NEC 690.34. 4.ADDITIONAL AC DISCONNECT(S) SHALL BE PROVIDED WHERE THE INVERTER IS NOT WITHIN SIGHT OF THE AC SERVICING DISCONNECT. 2.2.6 ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING TO NEC APPLICABLE CODES. 5.ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE WHEN APPROPRIATE. STRUCTURAL NOTES: 1.RACKING SYSTEM & PV ARRAY WILL BE INSTALLED ACCORDING TO CODE-COMPLIANT INSTALLATION MANUAL. TOP CLAMPS REQUIRE A DESIGNATED SPACE BETWEEN MODULES, AND RAILS MUST ALSO EXTEND A MINIMUM DISTANCE BEYOND EITHER EDGE OF THE ARRAY / SUBARRAY, ACCORDING TO RAI MANUFACTURER’S INSTRUCTIONS. 2.JUNCTION BOX WILL BE INSTALLED PER MANUFACTURERS' SPECIFICATIONS. IF ROOF-PENETRATING TYPE, IT SHALL BE FLASHED & SEALED PER LOCAL REQUIREMENTS. 3.ROOFTOP PENETRATIONS FOR PV RACEWAY WILL BE COMPLETED AND SEALED W/ APPROVED CHEMICAL SEALANT PER CODE BY A LICENSED CONTRACTOR. 4.ALL PV RELATED ROOF ATTACHMENTS TO BE SPACED NO GREATER THAN THE SPAN DISTANCE SPECIFIED BY THE RACKING MANUFACTURER. 2.3.6 WHEN POSSIBLE, ALL PV RELATED RACKING ATTACHMENTS WILL BE STAGGERED AMONGST THE ROOF FRAMING MEMBERS. WIRING & CONDUIT NOTES: 1.ALL CONDUIT AND WIRE WILL BE LISTED AND APPROVED FOR THEIR PURPOSE. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND ARE NOT MEANT TO LIMIT UP-SIZING. 2.CONDUCTORS SIZED ACCORDING TO NEC 690.8, NEC 690.7. 3.VOLTAGE DROP LIMITED TO 2%. 4.DC WIRING LIMITED TO MODULE FOOTPRINT. MICRO INVERTER WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ SUITABLE WIRING CLIPS. 5.AC CONDUCTORS COLORED OR MARKED AS FOLLOWS: PHASE A OR L1- BLACK PHASE B OR L2- RED, OR OTHER CONVENTION IF THREE PHASE PHASE C OR L3- BLUE, YELLOW, ORANGE**, OR OTHER CONVENTION NEUTRAL- WHITE OR GREY IN 4-WIRE DELTA CONNECTED SYSTEMS THE PHASE WITH HIGHER VOLTAGE TO BE MARKED ORANGE [NEC 110.15]. GROUNDING NOTES: 1.GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE, AND GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR SUCH USE. 2.PV EQUIPMENT SHALL BE GROUNDED ACCORDING TO NEC 690.43 AND MINIMUM NEC TABLE 250.122. 3.METAL PARTS OF MODULE FRAMES, MODULE RACKING, AND ENCLOSURES CONSIDERED GROUNDED IN ACCORD WITH 250.134 AND 250.136. 4.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZED ACCORDING TO NEC 690.45 AND MICRO INVERTER MANUFACTURERS’ INSTRUCTIONS. 5.EACH MODULE WILL BE GROUNDED USING WEEB GROUNDING CLIPS AS SHOWN IN MANUFACTURER DOCUMENTATION AND APPROVED BY THE AHJ. IF WEEBS ARE NOT USED, MODULE GROUNDING LUGS MUST BE INSTALLED AT THE SPECIFIED GROUNDING LUG HOLES PER THE MANUFACTURERS' INSTALLATION REQUIREMENTS. 6.THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT THE REMOVAL OFA MODULE DOES NOT INTERRUPT A GROUNDING CONDUCTOR TO ANOTHER MODULE. 7.GROUNDING AND BONDING CONDUCTORS, IF INSULATED, SHALL BE COLORED GREEN OR MARKED GREEN IF #4 AWG OR LARGER [NEC 250.119] 8.THE GROUNDING ELECTRODE SYSTEM COMPLIES WITH NEC 690.47 AND NEC 250.50 THROUGH 250.106. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, A GROUNDING ELECTRODE SYSTEM PROVIDED ACCORDING TO NEC 250, NEC 690.47 AND AHJ. 9.GROUND-FAULT DETECTION SHALL COMPLY WITH NEC 690.41(B)(1) AND (2) TO REDUCE FIRE HAZARDS DISCONNECTION AND OVER-CURRENT PROTECTION NOTES: 1.DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS OPENED THE CONDUCTORS REMAINING ENERGIZED ARE CONNECTED TO THE TERMINALS MARKED “LINE SIDE” (TYPICALLY THE UPPER TERMINALS). 2.DISCONNECTS TO BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL, BE LOCKABLE, AND BE A VISIBLE-BREAK SWITCH 3.PV SYSTEM CIRCUITS INSTALLED ON OR IN BUILDINGS SHALL INCLUDE A RAPID SHUTDOWN FUNCTION TO REDUCE SHOCK HAZARD FOR EMERGENCY RESPONDERS IN ACCORDANCE WITH 690.12(A) THROUGH (D). 4.ALL OCPD RATINGS AND TYPES SPECIFIED ACCORDING TO NEC 690.8, 690.9, AND 240. 5.MICRO INVERTER BRANCHES CONNECTED TO A SINGLE BREAKER OR GROUPED FUSES IN ACCORDANCE WITH NEC 110.3(B). 6.IF REQUIRED BY AHJ, SYSTEM WILL INCLUDE ARC-FAULT CIRCUIT PROTECTION ACCORDING TO NEC 690.11 AND UL1699B. INTERCONNECTION NOTES: 1.LOAD-SIDE INTERCONNECTION SHALL BE IN ACCORDANCE WITH [NEC 705.12] 2.THE SUM OF THE UTILITY OCPD AND INVERTER CONTINUOUS OUTPUT MAY NOT EXCEED 120% OF BUS BAR RATING [NEC 705.12(B)(3)(2)]. 3.THE SUM OF 125 PERCENT OF THE POWER SOURCE(S) OUTPUT CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE BUS BAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUS BAR, PV DEDICATED BACKFEED BREAKERS MUST BE LOCATED OPPOSITE END OF THE BUS FROM THE UTILITY SOURCE OCPD [NEC 705.12(B)(3)(1)]. 4.AT MULTIPLE ELECTRIC POWER SOURCES OUTPUT COMBINER PANEL, TOTAL RATING OF ALL OVERCURRENT DEVICES SHALL NOT EXCEED AMPACITY OF BUSBAR. HOWEVER, THE COMBINED OVERCURRENT DEVICE MAY BE EXCLUDED ACCORDING TO NEC 705.12 (B)(3)(3). 5.FEEDER TAP INTERCONNECTION (LOADSIDE) ACCORDING TO NEC 705.12 (B)(1) 6.SUPPLY SIDE TAP INTERCONNECTION ACCORDING TO NEC 705.11 WITH SERVICE ENTRANCE CONDUCTORS IN ACCORDANCE WITH NEC 230.42 2.7.8BACKFEEDING BREAKER FOR ELECTRIC POWER SOURCES OUTPUT IS EXEMPT FROM ADDITIONAL FASTENING [NEC 705.12 (E)]. Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" E 1.3 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 WARNING LABELS ! ! LABEL LOCATION: AC DISCONNECT/POINT OF INTERCONNECTION PER CODE: NEC 690.54 PHOTOVOLTAIC SYSTEM AC DISCONNECT RATED AC OUTPUT CURRENT:32.00 A NOMINAL OPERATING AC VOLTAGE:240 V LABEL LOCATION: RSD INITIATION DEVICE, AC DISCONNECT PER CODE: NEC 690.12(D)(2) LABEL LOCATION: MAIN SERVICE DISCONNECT PER CODE: NEC 690.12(D) ELECTRICAL SHOCK HAZARD TERMINALS ON THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION WARNING LABEL LOCATION: COMBINER PANEL, AC DISCONNECT, POINT OF INTERCONNECTION PER CODE: NEC 705.20(7), NEC 690.13(B) WARNING DUAL POWER SOURCE SECOND SOURCE IS PHOTOVOLTAIC SYSTEM LABEL LOCATION: MAIN SERVICE DISCONNECT, PRODUCTION/NET METER PER CODE: NEC 690.59, 705.30(C) LABEL LOCATION: MAIN SERVICE DISCONNECT, UTILITY METER PER CODE: NEC 690.13(B) POWER SOURCE OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE. WARNING LABEL LOCATION: POINT OF INTERCONNECTION PER CODE: NEC 705.12(B)(2) LABEL LOCATION: POINT OF INTERCONNECTION, COMBINER PANEL PER CODE: NEC 705.12(B)(3) TURN OFF PHOTOVOLTAIC AC DISCONNECT PRIOR TO WORKING INSIDE PANEL WARNING LABEL LOCATION: COMBINER PANEL(S), MAIN SERVICE DISCONNECT PER CODE: NEC 110.27(C), OSHA 1910.145(f)(7) ! ! ! ! THIS EQUIPMENT FED BY MULTIPLE SOURCES: TOTAL RATING OF ALL OVERCURRENT DEVICES EXCLUDING MAIN POWER SUPPLY SHALL NOT EXCEED AMPACITY OF BUSBAR WARNING! LABEL LOCATION: MAIN SERVICE DISCONNECT PER CODE: NEC 705.30(D), NEC 690.59 CAUTION PHOTOVOLTAIC SYSTEM CIRCUIT IS BACKFED ! SOLAR PV SYSTEM EQUIPPED WITH RAPID SHUTDOWN SOLAR ELECTRIC PV PANELS TURN RAPID SHUTDOWN SWITCH TO THE "OFF" POSITION TO SHUT DOWN PV SYSTEM AND REDUCE SHOCK HAZARD IN THE ARRAY DO NOT DISCONNECT UNDER LOAD LABEL LOCATION: MAIN SERVICE DISCONNECT PER CODE: NEC 690.15(B) & NEC 690.33(D)(2) RAPID SHUTDOWN FOR SOLAR PV SYSTEM MAIN PHOTOVOLTAIC SYSTEM DISCONNECT LABEL LOCATION: AC DISCONNECT PER CODE: NEC 690.13(B) PV SYSTEM DISCONNECT PHOTOVOLTAIC POWER SOURCE LABEL LOCATION: DC CONDUIT, DC JUNCTION BOX PER CODE: NEC 690.31(D)(2) SOLAR PV DC CITCUIT LABEL LOCATION: DC CONDUIT, DC JUNCTION BOX PER CODE: NEC 690.31(D)(2) ! MULTIPLE SOURCES OF POWER CAUTION: MAIN SERVICE PANEL M AC C UTILITY METER AC COMBINER PANEL AC DISCONNECT 15 8 1 2 9 0 T H A V E S E 18 PV MODULES Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 01 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 PV MODULE SPECIFICATION SHEET Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 02 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 MICROINVERTER SPECIFICATION SHEET Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 03 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 COMBINER PANEL CERTIFICATION Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 04 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 AC DISCONNECT UL CERTIFICATION Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 05 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 JUNCTION BOX UL CERTIFICATION Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 06 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 WIRING SPECIFICATION Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 07 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 MOUNTING - DATA SHEET Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 08 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 RACKING - DATA SHEET Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 09 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 SPLICE KIT- DATA SHEET Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 10 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 GROUNDING - DATA SHEET Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 11 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 MID CLAMP - DATA SHEET Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 12 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 END CLAMP - DATA SHEET Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 13 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 CHIKO USA UL LISTING CERTIFICATE Rev DA W N F O X R E S I D E N C E 15 8 1 2 9 0 T H A V E S E YE L M , WA 98 5 9 7 PH O N E : - N/ A EM A I L : - N/ A DateDescription REVISIONS Signature with Seal Project Name & Address Sheet Size Sheet Number ANSI B 11" X 17" DS 14 Sheet Name INFINITY HOME SOLUTIONS 6405 E MILL PLAIN VANCOUVER WA 98661 PHONE: 1-800-818-0598 INFINITY SOLAR.COM Initial Design 0012/18/25 Customer Address: Customers Name: Date: Prepared by: Nearest Hospital/urgent care: Manger contact: Information: Site Specific Safety Map: Red dashed lines: Roof edges (fall hazards). Blue arrows: Ladder/scaffold access points. Yellow zones: Material storage areas. Lightning bolt icons: Electrical panels/PV arrays. Green star: Emergency assembly point (driveway). Signatures: Journeyman Electrician: Apprentice: Roof Lead: Roof Installer: Roof Installer: SITE SAFETY MAP