Loading...
HomeMy WebLinkAboutS26-001 - Pulse Heart Yelm - Product Data 7855 South 206th ST Kent, WA 98032 Phone: 253-872-7222 FIRE SPRINKLER EQUIPMENT SUBMITTAL FOR Pulse Heart 902 E. Yelm Ave, Ste A Yelm, WA Archer Job # S26-001 Model F1FR56 UprightModel F1FR56 Pendent Model F1FR56 Horizontal Sidewall Model F1FR56 Vertical Sidewall Note: Not all versions of the product are shown. F1FR Series Sprinkler Summary Sprinkler Model K-Factor gpm/psi1/2 (lpm/bar1/2)Orientation Listings & Approvals Max. Working Pressure psi (bar) Sprinkler Identification Number (SIN) F1FR56 5.6 (80) Upright Intermediate Upright cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1425 Pendent cULus, FM, LPCB, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Concealed Pendent cULus, VdS, EC, WM, UKCA 175 (12) 250 (17) (cULus only)RA1414 Horizontal Sidewall cULus, FM 175 (12)RA1435 Vertical Sidewall cULus, FM, LPCB, UKCA 175 (12)RA1485 Table A Note: This bulletin may contain information on New and Legacy sprinklers that reflects a dimensional change only. Sprinkler Iden- tification Number (SIN), application, performance, and listings/ approval are not otherwise affected. Sprinklers with New frames will include the suffix “N” in the order. Features • Standard coverage quick-response sprinklers • Upright, pendent, horizontal sidewall, and vertical sidewall deflectors • Low profile, compact design • Available in a wide variety of finishes Product Description Reliable Model F1FR56 series sprinklers are quick-response standard spray automatic fire sprinklers utilizing a sensitive 3.0 mm glass bulb thermal element. Pendent and horizontal sidewall sprinklers may be installed exposed or surface mounted using escutcheons such as the Reliable Models B, C, or HB (reference Technical Bulletin 204). When installed recessed or concealed, the Model F1FR56 series sprinklers are specifically listed with and may only be installed with listed Reliable escutcheons and cover plates. Refer to the technical information on the following pages for specific listings for recessed and concealed installations and refer to Figures 5 and 6 for dimensional information. When fitted with an approved water shield, these sprinklers may considered intermediate sprinklers for use in racks, below grated walkways, and other areas where intermediate level sprinklers are required. Table A provides a summary of the approvals and availability of specific Model F1FR series sprinkler configurations. Additional technical information for each sprinkler model is provided on the following pages. www.reliablesprinkler.com K-factor 5.6 (80) F1FR56 Series Quick Response Sprinklers Bulletin 074 November 2023 Model F1FR56 Upright Sprinkler SIN RA1425 Technical Specifications Style: Upright, Intermediate Upright Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) Factory Water Shield (cULus, FM) F-1 Guard (cULus, FM) F-3 Guard with Shield (cULus, FM) Guards and Shields (Legacy Frames) Factory Water Shield C-1 Guard (FM) C-3 Guard with Shield (cULus, FM) D-1 Guard (cULus) D-3 Guard with Shield (cULus) Sprinkler Wrench Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045 Model F1FR56 Upright Sprinkler Components and Dimensions Figure 1 Deflector Glass Bulb (3 mm) Wrench Flat Threads 1 3/8" [33mm] 3 1/4" [83mm] Cap/Seal Assembly Load Screw 2 1/4" [58mm] F1FR_HALF_UPR_INT Shown with Optional Factory Installed Water Shield ( Intermediate Upright) Bulletin 074 November 2023 Page 2 of 9 www.reliablesprinkler.com Model F1FR56 Pendent Sprinkler SIN RA1414 Technical Specifications Style: Pendent Recessed Pendent Concealed Pendent Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) 250 psi (17 bar) (cULus only) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings(1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons Model F1 (cULus, LPCB, VdS, CE, WM) Model F2 (cULus, FM, LPCB, VdS, CE, WM) Model FP (cULus, VdS, CE, WM) Cover Plate Model CCP (cULus, VdS(2), CE(2)) Guards & Shields (New Frames)(3) F-1 Guard (FM) F-5 Guard/Shield Kit (FM) F-7 Guard (cULus) F-8 Guard/Shield Kit (cULus) S-1 Shield (cULus, FM) Guards & Shields (Legacy Frames)(3) C-1 Guard (FM) C-5 Guard/Shield Kit (FM) D-1 Guard (cULus, FM) D-4 Guard/Shield Kit (FM) D-5 Guard/Shield Kit (cULus, FM) S-1 Shield (cULus, FM) Sprinkler Wrenches Model W2 (pendent) Model W4 (recessed or concealed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(4) cULus Listed FM Approved LPCB VdS EC WM UKCA: 0832-UKCA-CPR-S5045, 0831-UKCA-CPR-5072 (CCP) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed or concealed use. 2. VdS and CE approval for CCP concealed use is for 155°C (68°C) sprinkler ONLY. 3. Not suitable for recessed or concealed pendent installations. 4. When used surface mounted or exposed. See Recessed Escutcheon and Cover Plate section for specific approvals when installed recessed or concealed. Model F1FR56 Pendent Sprinkler Components and Dimensions Figure 2 F1FR_HALF_PEND_INT Deflector Glass Bulb (3 mm) Wrench Flat Threads 3 1/4" [83mm] 2 1/4" [57mm] 1" [25mm]Load Screw Cap/Seal Assembly Shown with Optional S-1 Water Shield (Ordered Separately) Note: Please refer to Figure 8 for recessed and concealed installation. Bulletin 074 November 2023 Page 3 of 9 www.reliablesprinkler.com Model F1FR56 Horizontal Sidewall Sprinkler SIN RA1435 Technical Specifications Style: Horizontal Sidewall Recessed Horizontal Sidewall Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings (1) 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Recessed Escutcheons(2) Model F1 (cULus) Model F2 (cULus, FM) Model FP (cULus) Guards & Shields (New Frames)(3) F-4 Guard (FM) F-7 Guard (cULus) Guards & Shields (Legacy Frames)(3) C1 Guard (FM) D1 Guard (cULus) Sprinkler Wrenches Model W2 (non-recessed) Model W4 (recessed) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals cULus Listed(4) FM Approved(5) Notes: 1. 286°F (141°C) temperature rated sprinkler not listed for recessed use. 2. FM approved recessed installation when used with Model F2 escutcheon ONLY. 3. Not suitable for recessed horizontal sidewall installations. 4. cULus Listed for Light and Ordinary Hazard when installed exposed or surface mounted. Listed for Light Hazard ONLY when installed recessed. 5. FM Approved for Light Hazard ONLY. Model F1FR56 Horizontal Sidewall Sprinkler Components and Dimensions Figure 3 Bulletin 074 November 2023 Page 4 of 9 www.reliablesprinkler.com F1FR_HALF_HSW 2 3/4" [70mm] 1 1/8" [28mm] Threads Cap/Seal Assembly Load ScrewDeflector Glass Bulb (3 mm) Wrench Flat Frame Note: Please refer to Figure 9 for recessed installation. Model F1FR56 Vertical Sidewall Sprinkler SIN RA1485 Technical Specifications Style: Upright Vertical Sidewall Pendent Vertical Sidewall Threads: 1/2” NPT or ISO 7-R1/2 Nominal K-Factor: 5.6 (80 metric) Max. Working Pressure: 175 psi (12 bar) Material Specifications Thermal Sensor: 3 mm Glass Bulb Sprinkler Frame: Brass Alloy Cap: Bronze Alloy Sealing Washer: Nickel with PTFE Load Screw: Copper Alloy Deflector: Brass Alloy Sprinkler Finishes (See Table B) Sensitivity Quick response Temperature Ratings 135°F (57°C) 155°F (68°C) 175°F (79°C) 200°F (93°C) 286°F (141°C) Guards & Shields (New Frames) F-2 Guard (FM) Guards & Shields (Legacy Frames) C1 Guard (FM) Sprinkler Wrenches Model W2 Model J (New frame with guard installed) Model JD (Legacy frame with guard installed) Listings and Approvals(1) cULus Listed FM Approved LPCB(2) UKCA: 0832-UKCA-CPR-S5045 Notes: 1. Listed and approved for Light Hazard ONLY. 2. LPCB approved for use in pendent position ONLY. Model F1FR56 Vertical Sprinkler Components and Dimensions Figure 4 Bulletin 074 November 2023 Page 5 of 9 www.reliablesprinkler.com F1FR_HALF_VSW 2 1/4" [57mm] 1 1/2" [38mm] Threads Cap/Seal Assembly Load ScrewDeflector Glass Bulb (3 mm) Wrench Flat Frame Models F1 & F1FR Pendent Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment 2-7/8" (72 mm) Dia. 1-3/4" (44 mm) 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. Minimum Recess Maximum Recess 1" (25 mm) Face of Fitting to Face of Ceiling 1-1/8" (29 mm) at Max. Recess 3/8" (10 mm) at Min. Recess Models F1 & F1FR Pendent Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment 1" (25 mm) 2-5/16" (59 mm) Dia. Minimum Recess Maximum Recess 1/2" (12 mm) 3-3/16" (78 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 2-7/8" (72 mm) Dia. 1-3/4" (44 mm) Minimum Recess Maximum Recess 1-1/4" (32 mm) Face of Fitting to Face of Ceiling 7/8" (22 mm) at Max. Recess 3/8" (10 mm) at Min. Recess 2-1/4" (57 mm) Dia. Hole in Ceiling 1-15/16" (49 mm) Dia. 2-1/2" (64 mm) Dia. Hole in Ceiling Models F1 & F1FR Pendent Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Reducing Fitting Reducing Fitting Reducing Fitting Note: Model FP recessed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Vented Cup Model F1FR56 CCP Conical Concealed Sprinkler 1/2" (13mm) Nominal Adjustment (Nominal Cover Plate Projection is 1" (25 mm)) 1" (25 mm) 2-5/16" (59 mm) Dia. Minimum Recess Maximum Recess 1/2" (12 mm) 3-5/16" (84 mm) Dia. Face of Fitting to Face of Ceiling 1-1/2" (38 mm) at Max. Recess 1" (25 mm) at Min. Recess 2-1/2" (64 mm) Dia. Hole in Ceiling F1_REC_PEND_CCP Reducing Fitting Note: Model CCP concealed assemblies may not be used where the pressure in the space above the ceiling is positive with respect to the protected area. Ensure that the openings in the Model CCP cup are unobstructed following installation. Vented Cup Recessed and Concealed Installation: Pendent Sprinklers Figure 5 FP EscutcheonF1 Escutcheon (F2 Similar) CCP Cover Plate Bulletin 074 November 2023 Page 6 of 9 www.reliablesprinkler.com 2-1/4" (57 mm) Dia. Hole 1-15/16" (49 mm) Dia. 2-1/4" (57 mm) Dia. Hole 1-15/16" (49 mm) DIA. 2-7/8" (73 mm) Dia. 2-7/8" (73 mm) Dia. 2-1/8" (54 mm) Minimum Recess 1-5/8" (42 mm) Maximum Recess 2 1/8" (54 mm) Minimum Recess 1-3/8" (35 mm) Maximum Recess 2-5/8" (67 mm) Dia Hole. 2-5/16" (58 mm) Dia. 3-1/4" (83 mm) Dia. 1-1/4" (32 mm) +/-1/4" (6 mm) Face of fitting to face of wall 1-3/8" (35 mm) Minimum Recess 7/8" (22 mm) Maximum Recess 3/8" (16 mm) +/-1/4" (6 mm) Face of fitting to face of wall 1/2" (12 mm) +/- 3/8" (10 mm) Face of fitting to face of wall 4" - 12" (102 mm - 305 mm) Deflector to ceiling F1FR_REC_HSW Reducing Fitting Reducing Fitting Reducing Fitting 9/16" [14mm] Model F1FR Horizontal Sidewall Sprinkler with Model FP Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Model F1FR Horizontal Sidewall Sprinkler with Model F2 Recessed Escutcheon 1/2" (13mm) Nominal Adjustment Model F1FR Horizontal Sidewall Sprinkler with Model F1 Recessed Escutcheon 3/4" (19mm) Nominal Adjustment F2 Recessed escutcheon 1/2" (13 mm) Adjustment F1 Recessed escutcheon 3/4" (19 mm) Adjustment 4" - 12" (102 mm - 305 mm) Deflector to ceiling 9/16" [14mm] 4" - 12" (102 mm - 305 mm) Deflector to ceiling 9/16" [14mm] Note: Model FP recessed assemblies may not be used where the pressure in the space behind the sprinkler is positive with respect to the space in the protected area. Ensure that the openings in the Model FP cup are unobstructed following installation. Vented Cup Recessed Installation: Horizontal Sidewall Sprinklers Figure 6 Bulletin 074 November 2023 Page 7 of 9 www.reliablesprinkler.com Installation Model F1FR Series sprinklers must be installed in accordance with NFPA13 and the requirements of all applicable authorities having jurisdiction. Model F1FR Series sprinklers must be installed with the Reliable sprinkler installation wrench identified in this Bulletin. Any other wrench may damage the sprinkler. The Models W2 and W4 wrenches have two sets of jaws. Use the smallest set of jaws that fit on the wrench flats of the sprinkler. A leak tight sprinkler joint can be obtained with a torque of 8 to 18 lb-ft (11 to 24 N.m). Do not tighten sprinklers over the maximum recommended installation torque. Exceeding the maximum recommended installation torque may cause leakage or impairment of the sprinkler. Glass bulb sprinklers have orange bulb protectors or protective caps to minimize bulb damage during shipping, handling and installation. Reliable sprinkler installation wrenches are designed to install sprinklers with bulb protectors in place. Remove the bulb protector at the time when the sprinkler system is placed in service for fire protection. Removal of the bulb protector before this time may leave the bulb vulnerable to damage. Remove bulb protectors by undoing the clasp by hand. Do not use tools to remove bulb protectors. Standard Finishes Special Application Finishes Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2)Sprinkler F1, F2 and FP(2) Escutcheons CCP Cover Plate(2) Bronze Brass Chrome Electroless Nickel PTFE(3)(4)Bright Brass Bright Brass Chrome Chrome White Paint Bright Brass(5)Satin Chrome Satin Chrome White Polyester(3)White Polyester Satin Chrome Custom Color Polyester Custom Color Paint Custom Color Polyester(3) Notes: 1. Paint or any other coating applied over the factory finish will void all approvals and warranties. 2. Model FP escutcheons and Model CCP sprinklers utilize a galvanized steel cup with a finished trim ring or cover plate. 3. cULus Listed as corrosion resistant. 4. FM Approved as corrosion resistant. 5. For 200°F (93°C) maximum temperature rated sprinklers only. Finishes(1)Table B Maintenance Reliable Model F1FR series sprinklers should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Prior to installation, sprinklers should remain in the original cartons and packaging until used. This will minimize the potential for damage to sprinklers that could cause improper operation or non-operation. Do not clean sprinklers with soap and water, ammonia liquid or any other cleaning fluids. Remove dust by gentle vacuuming without touching the sprinkler. Replace any sprinkler which has been painted (other than factory applied). A stock of spare sprinklers should be maintained to allow quick replacement of damaged or operated sprinklers. Failure to properly maintain sprinklers may result in inadvertent operation or non-operation during a fire event. Wrenches Model W2 (upright, pendent) Model J (New frame with guard installed) Model JD (Legacy frame with guard installed, similar but with zinc finish)Model W4 (recessed, concealed pendent) Bulletin 074 November 2023 Page 8 of 9 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 6 2 3 Bulletin 074 November 2023 Page 9 of 9 www.reliablesprinkler.com Guarantee For the guarantee, terms, and conditions, visit www. reliablesprinkler.com. Ordering Information Specify the following when ordering: Model • F1FR56 Deflector/Orientation • Upright • Intermediate Upright • Pendent • CCP Concealed Pendent • Horizontal Sidewall • Vertical Sidewall Temperature Rating • See sprinkler technical specifications Sprinkler Finish • See Table B Recessed Escutcheon(1)(2) • F1 • F2 • FP Escutcheon Finish • See Table B CCP Cover Plate Temperature Rating • 135°F (57°C) [For use with 135°F (57°C) and 155°F (68°C) sprinklers.] • 165°F (74°C) [For use with 175°F (79°C) and 200°F (93°C) sprinklers.] CCP Cover Plate Finish • See Table B Sprinkler Wrench • Model W2 • Model W4 (recessed, concealed) • Model J (New frame with guard installed) • Model JD (Legacy frame with guard installed) Notes: 1. 286°F (141°C) sprinklers are not listed to be used recessed or concealed. 2. For FM, recessed sprinklers must use the Model F2 escutcheon. Ordering Information Specify: Model Name • Model RFB Nominal Hose Length • 24” (610 mm) • 31” (790 mm) • 40” (1015 mm) • 48” (1220 mm) • 60” 1525 mm) • 72” (1830 mm) Reducer Outlet: 1/2” NPT or 3/4” NPT Reducer Type Standard: • 6-1/8” (155 mm) straight Optional: • 4-5/16” (110 mm) straight • 5-5/16” (135 mm) straight • 11-3/4” (300 mm) straight • 5-5/8” (143 mm) elbow • 7-3/8” (187 mm) elbow Bracket Assembly Length • 24” (610 mm) standard • 48” (1220 mm) optional Accessories • See Table F Maximum Working Pressure FM: 200 psi (13.8 bar) UL: 175 psi (12.1 bar) Maximum Working Temperature 300°F (149°C) Connections Inlet/Branch Line 1” NPT Outlet/Reducer 1/2” or 3/4” NPT Minimum Allowable Bending Radius UL: 3” (76 mm) FM: 7” (178 mm) Maximum Number of Bends See Friction Loss Chart Maximum K-Factor 1/2” Outlet 5.6 (80 metric) 3/4” Outlet 14.0 (200 metric) Table ATechnical Data Maintenance RASCOFLEX® Sprinkler Connections should be inspected and the sprinkler system maintained in accordance with NFPA 25, as well as the requirements of any Authorities Having Jurisdiction. Patents RASCOFLEX® Sprinkler Connections may be covered by one or more of the following US Patent Nos. 10,173,088 and 10,328,296. Listings and Approvals FM Approved Class No. 1637 (FM) UL Listed and UL Certified for Canada to ANSI/UL 2443 (cULus) Product Description RASCOFLEX® Sprinkler Connections are intended to connect a branch line to a sprinkler using a flexible stainless steel hose assembly. RASCOFLEX® Sprinkler Connections are suitable for use in suspended and hard ceiling applications such as T-Bar ceiling grids, wood, metal stud, or hat furring channel hard lid ceilings. Every package contains one (1) fully assembled stainless steel flexible sprinkler system complete with hose, branch line connection, and sprinkler connection, as well as the pre- assembled bracket assembly to attach to the ceiling. RASCOFLEX® Sprinkler Connections are designed for use in hydraulically calculated wet, preaction, or dry sprinkler systems per NFPA 13, 13R, 13D, and FM Global Loss Prevention Data Sheets. www.reliablesprinkler.com cULus Listed, FM Approved Model RFB RASCOFLEX® Sprinkler Connections Bulletin 213 September 2024Availability: Americas RASCOFLEX® Sprinkler Connections Bracket Dimensions Figure 1 Reducer Dimensions Figure 2 Bulletin 213 September 2024 Page 2 of 8 www.reliablesprinkler.com Minimum and Maximum Face of Fitting to Bottom of Ceiling Grid for Each Reducer Table B Fitting Distance 6-1/8” (155mm) Straight Standard 4-5/16” (110mm) Straight 5-5/16” (135mm) Straight 11-13/16” (300mm) Straight 5-5/8” (143mm) Elbow 7-3/8” (187mm) Elbow Max. Face of Fitting Distance Above Bottom of Ceiling Grid 3” (77mm)3” (7mm)3” (7mm)3” (7mm)3” (7mm)3” (7mm) Max. Face of Fitting Distance from Bottom of Ceiling Grid 1/8” (3mm) below 1-5/8” (42mm) above 11/16” (17mm) above 6-3/8” (148mm) below 1-7/16” (36mm) above 5/16” (60mm) below Note: Based on 1-11/16” (43mm) tall ceiling grid. Fig. 3 Dimension C - Clearance Above Ceiling Required at Max. Sprinkler Recess Table C Recessed Escutcheon or Concealed/Flush Sprinkler Reducer 5-5/8” (143mm) Elbow 7-3/8” (187mm) Elbow F1 recessed escutcheon NC 5-5/8” (144mm) F2 or FV recessed escutcheon NC 5-3/8” (138mm) FP recessed escutcheon NC 6-1/4” (160mm) CCP conical concealed cover plate NC 6-1/4” (160mm) G4 series concealed sprinklers 5-5/8” (144mm)7-3/8” (188mm) G5 series concealed sprinklers 5-1/4” (134mm)7” (179mm) RFC series concealed sprinklers 5-1/4” (134mm)7” (179mm) XL commercial flush sprinkler with flat escutcheon 4-7/8” (125mm)6-5/8” (169mm) XL commercial flush sprinkler with conical escutcheon 4-3/8” (112mm)6-1/8” (157mm) Note: NC - Reducer not compatible with sprinkler adjustment range. Based on 1-11/16” (43mm) tall ceiling grid and flush ceiling tile. Installation Dimensions Figure 3 Bulletin 213 September 2024 Page 3 of 8 www.reliablesprinkler.com Materials Figure 4 Number Item Description Material 1 Flexible Hose/Bellow AISI Type 304 Stainless Steel 2 Isolation Ring Nylon 66 3 Gasket EPDM 4 Nut Zinc Plated Carbon Steel 5 Branch Line Nipple (1”)Zinc Plated Carbon Steel 6 Reducer Zinc Plated Carbon Steel 7 Braid AISI Type 304 Stainless Steel 8 Welded Collar Fitting AISI Type 304 Stainless Steel -Bar Stock Zinc Plated SGCC Steel -Brackets: Center and Side Zinc Plated SPCC Steel 8 2 3 4 6 75 1 Bulletin 213 September 2024 Page 4 of 8 www.reliablesprinkler.com Do NOT install the RASCOFLEX™ straight. Some flexibility in the form of an allowable bend (or bends) must be provided. Flexible Hose Number of Bends Figure 5 One Bend Two Bends Three Bends Minimum bend radius Minimum bend radius Minimum bend radius Minimum bend radius 2x Min bend radius ORMinimum bend radius 90° Minimum bend radiusMinimum bend radius 2x Min bend radius OR cULus Friction Loss Data Table D Nominal Length of Flexible Hose in (mm) Reducer Maximum Sprinkler K-Factor gpm/psi1/2 (lpm/bar1/2) Maximum Number of 90° Bends at 3” (76mm) Bend Radius Equivalent Length of 1” (33.7mm) Sch. 40 Pipe (C=120), ft (m)NPT Threads Type 24 (610) 1/2 Straight 5.6 (80)2 10 (3) 3/4 Straight 14.0 (200)2 13 (4) 31 (790) 1/2 Straight 5.6 (80)3 14 (4.3) 3/4 Straight 14.0 (200)3 16 (4.9) 40 (1015) 1/2 Straight 5.6 (80)4 21 (6.4) 3/4 Straight 14.0 (200)4 23 (7) 48 (1220) 1/2 Straight 5.6 (80)4 24 (7.3) 3/4 Straight 14.0 (200)4 26 (7.9) 60 (1525) 1/2 Straight 5.6 (80)4 25 (7.6) 3/4 Straight 14.0 (200)4 30 (9.1) 72 (1830) 1/2 Straight 5.6 (80)5 36 (11) 3/4 Straight 14.0 (200)5 33 (10.1) UL Notes: 1. Available data for use with 6.1” straight reducers. 2. Sprinkler K-Factor: 5.6 (80 metric) for 1/2-inch reducer and 14.0 (200 metric) for 3/4-inch reducer. 3. RASCOFLEX® Sprinkler Connections have been tested and approved by Underwriter’s Laboratories, Inc. for use in wet, preaction, and dry sprinkler systems per NFPA 13, 13D, 13R and UL2443. CAMERA-READY LOGOTYPE FOR TYPE L AND TYPE R LISTING MARKS FOR CANADA AND THE U.S. These Marks are registered by Underwriters Laboratories Inc. The minimum height of the registered trademark symbol ® shall be 3/64 of an inch. When the overall diameter of the UL Mark is less than 3/8 of an inch, the trademark symbol may be omitted if it is not legible to the naked eye. The font for all letter forms is Helvetica Condensed Black, except for the trademark symbol ®, which is Helvetica Condensed Medium. No other fonts are acceptable. Please Note: The word "MARINE" should only be used for UL Classified marine products. 200-195F 20M/11/97 Note: All Reliable RASCOFlex products may be painted provided the paint is compatible with the following materials of construction: • Stainless steel • Zinc-plated carbon steel • Ductile iron Care should be taken to ensure that the sprinkler and associated escutcheon or cover plate are not painted. Additionally, care should be taken to avoid painting over any manufacturer or product identifying markings or tags on the flexible drop. No paint of any kind should be applied to threads or components / surfaces that comprise a pressure-containing seal. Bulletin 213 September 2024 Page 5 of 8 www.reliablesprinkler.com FM Friction Loss Data Table E Nominal Length of Flexible Hose in (mm) Reducer Maximum Sprinkler K-Factor gpm/psi1/2 (lpm/bar1/2) Maximum Number of 90° Bends at 7” 178mm) Bend Radius Equivalent Length of 1” (33.7mm) Sch. 40 Pipe (C=120), ft (m)NPT Threads Type 24 (610) 1/2 Straight 5.6 (80)1 9.7 (2.9) 1/2 90° Elbow 5.6 (80)0 11.5 (3.5) 3/4 Straight 8.0 (115)1 9.9 (3) 11.2 (160)1 9.8 (2.9) 14.0 (200)1 9.6 (2.9) 3/4 90° Elbow 8.0 (115)0 10.2 (3.1) 11.2 (160)0 10 (3) 14.0 (200)0 9.8 (2.9) 31 (790) 1/2 Straight 5.6 (80)2 12.4 (3.8) 1/2 90° Elbow 5.6 (80)2 15.8 (4.8) 3/4 Straight 8.0 (115)2 13.7 (4.1) 11.2 (160)2 12.9 (3.9) 14.0 (200)2 12.2 (3.7) 3/4 90° Elbow 8.0 (115)2 14.5 (4.4) 11.2 (160)2 13.7 (4.1) 14.0 (200)2 13 (3.9) 40 (1015) 1/2 Straight 5.6 (80)2 15.9 (4.8) 1/2 90° Elbow 5.6 (80)2 21.6 (6.6) 3/4 Straight 8.0 (115)2 18.5 (5.6) 11.2 (160)2 17.4 (5.3) 14.0 (200)2 16.3 (4.9) 3/4 90° Elbow 8.0 (115)2 20 (6) 11.2 (160)2 18.9 (5.7) 14.0 (200)2 20 (6) 48 (1220) 1/2 Straight 5.6 (80)3 19.0 (5.8) 1/2 90° Elbow 5.6 (80)3 25.9 (7.9) 3/4 Straight 8.0 (115)3 22.7 (6.9) 11.2 (160)3 21.5 (6.5) 14.0 (200)3 20.5 (6.2) 3/4 90° Elbow 8.0 (115)3 24.8 (7.5) 11.2 (160)3 23.6 (7.2) 14.0 (200)3 22.6 (6.8) Bulletin 213 September 2024 Page 6 of 8 www.reliablesprinkler.com FM Notes: 1. RASCOFLEX® Sprinkler Connections have been tested and approved by FM Approvals for use in wet, preaction, and dry sprinkler systems per FM data sheets 2-0, 2-5, and 2-8 per FM1637. 2. Maximum sprinkler K-Factor: 5.6 (80 metric) for 1/2-inch reducer and 14.0 (200 metric) for 3/4-inch reducer. 3. Differences in equivalent lengths are due to varying test methods, per FM 1637 standards. 4. Above data of friction loss for use with 6.1” straight reducers. Nominal Length of Flexible Hose in (mm) Reducer Maximum Sprinkler K-Factor gpm/psi1/2 (lpm/bar1/2) Maximum Number of 90° Bends at 7” (178mm) Bend Radius Equivalent Length of 1” (33.7mm) Sch. 40 Pipe (C=120), ft (m)NPT Threads Type 60 (1525) 1/2 Straight 5.6 (80)4 23.7 (7.2) 1/2 90° Elbow 5.6 (80)4 33.1 (10) 3/4 Straight 8.0 (115)4 29.1 (8.8) 11.2 (160)4 28 (8.5) 14.0 (200)4 27 (8.2) 3/4 90° Elbow 8.0 (115)4 32.2 (9.8) 11.2 (160)4 31.1 (9.5) 14.0 (200)4 30 (9.1) 72 (1830) 1/2 Straight 5.6 (80)4 28.4 (8.6) 1/2 90° Elbow 5.6 (80)4 40.4 (12.3) 3/4 Straight 8.0 (115)4 35.5 (10.8) 11.2 (160)4 34.3 (10.4) 14.0 (200)4 33.2 (10.1) 3/4 90° Elbow 8.0 (115)4 39.5 (12) 11.2 (160)4 38.3 (11.6) 14.0 (200)4 37.2 (11.3) FM Friction Loss Data (cont.)Table E Bulletin 213 September 2024 Page 7 of 8 www.reliablesprinkler.com Table FAccessories List 7-3/8” (187mm) Elbow Reducer- Long 1/2”: 7M99003302 3/4”: 7M99003304 4-5/16” (110mm) Straight Reducer 1/2”: 7M99003306 3/4”: 7M99003325 11-13/16” (300mm) Straight Reducer 1/2”: 7M99003309 3/4”: 7M99003328 Metal Stud End Bracket-Short 1-1/2” (38mm) 7M99003312 Wood Beam Stud End Bracket 7M99003317 3” (76 mm) Bend Radius Indicator 7M99004179 5-5/16” (135mm) Straight Reducer 1/2”: 7M99003307 3/4”: 7M99003326 Hat Channel End Bracket- Short 3” (76mm) 7M99003310 Metal Stud End Bracket- Long 2-1/16” (53mm) 7M99003313 Replacement Center Bracket 7M99003321 Replacement Gasket 7M99004319 Replacement 6-1/8” (155mm) Standard Straight Reducer 1/2”: 7M99003308 3/4”: 7M99003327 Hat Channel End Bracket- Long 3-3/4” (95mm) 7M99003311 T-Bar End Bracket- Long 4-1/8” (105mm) 7M99003316 Replacement 1” NPT Inlet Adapter 7M99003322 #2 Square Drive Bit 7M99004539 5-5/8” (143mm) Elbow Reducer- Short 1/2”: 7M99003303 3/4”: 7M99003305 48” (1220mm) Bracket Assembly 7M99003301 T-Bar End Bracket- Short 2-5/8” (68mm) 7M99003314 Bulletin 213 September 2024 Page 8 of 8 www.reliablesprinkler.com P/ N 9 9 9 9 9 7 0 5 6 0