HomeMy WebLinkAboutPulseHeartClinicYelm - Plumbing Permit Set+36+36
EXISTING ELECTRICAL
PANEL TO REMAIN
REMOVE EXISTING
STUDWALLS SHOWN
DASHED, TYP.
EXISTING PLUMBING
ROUGH-IN FOR W.C.
MODIFY AS NEEDED FOR
NEW W.C. LOCATION
EXISTING PLUMBING
ROUGH-IN FOR W.C.
MODIFY AS NEEDED FOR
NEW W.C. LOCATION
REMOVE EX. ELECTRICAL
OUTLETS AND ALL RELATED
WIRING BACK TO ELECTRICAL
PANEL.
±9'-6" VERIFY
±5'-0" VERIFY±13'-8" VERIFY
1'
-
4
7
8"
EXISTING INTERIOR
DEMISING WALL w/
G.W.B. TAPED.
EXISTING EXTERIOR
WALL w/ G.W.B. TAPED.
EX. ALUM. STOREFRONT DOOR.
SEE DOOR SCHEDULE FOR
HARDWARE MODIFICATIONS.
EX. ALUM. FRAME
WINDOW TO REMAIN
EXISTING EXPOSED
PLUMBING PIP IN SLAB
TO BE ENCLOSED PER
NEW FLOOR PLAN.
PROPOSED LOCATION OF
SAW-CUT FOR NEW PLUMBING
WASTE LINE. VERIFY FINAL
LOCATION PER BIDDER DESIGN
PLUMBING SUBCONTRACTOR.
EX. ALUM. FRAME
WINDOW TO REMAIN
EX. ALUM. FRAME
WINDOW TO REMAIN
EX. ALUM. FRAME
WINDOW TO REMAIN
CREATE OPENING IN
EXISTING EXTERIOR WALL
FOR NEW EXTERIOR DOOR.
VERIFY LOCATION OF EX.
ELECTRICAL GEAR ON
EXTERIOR WALL
4'
-
8
"
3'
-
4
"
REMOVE EXISTING DOOR
HARDWARE AND LOCK
DOOR IN PLACE.
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
DEMOLITION PLAN 00 4 8
NORTH
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
225-3590
11/10/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/10/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
A2.2
PE
R
M
I
T
S
E
T
EXAM #1103 EXAM #2104
EXAM #4111
EXAM #8114EXAM #7115EXAM #6116
EXAM #3109
TOILET #2106TOILET #1105
BREAK ROOM108
PROVIDERS113
I.T.118
WAITING ROOM101
RECEPTION102
ECHO119
LEADER112
M.A.110
JAN.107
HOTEL117
FE
EX. 4" S.S. WASTE
LINE (VERIFY
LOCATION)NEW 4" S.S. WASTE LINE
(VERIFY LOCATION)
NEW 3"Ø S.S.
WASTE LINE
NEW 3"Ø S.S.
WASTE LINE
NEW 3"Ø S.S.
WASTE LINE
EXAM #1103 EXAM #2104
EXAM #4111
EXAM #8114EXAM #7115EXAM #6116
EXAM #3109
TOILET #2106TOILET #1105
BREAK ROOM108
PROVIDERS113
I.T.118
WAITING ROOM101
RECEPTION102
ECHO119
LEADER112
M.A.110
JAN.107
HOTEL117
FE
NEW BREAK
ROOM D.W.
NEW SUPPLY FOR
REFER. ICE-MAKER
SINK
WCWC
LAV LAV
MOP SINK
ELECTRIC WATER
HEATER
ECHO ROOM
SINK
PROVIDE NEW SHUT-OFF
VALVE FROM EX. COLD
WATER SUPPLY
1"Ø COLD WATER
LINE, TYP.
1"Ø HOT WATER
LINE, TYP.
1"Ø COLD WATER
LINE, TYP.
2" VENTTHRU ROOF
2" VENTTHRU ROOF
2" VENT
THRU ROOF
2" VENTTHRU ROOF
ECHO ROOMSINK
WC
WC
MOP SINK
LAV
LAV
BREAK
ROOM SINK(TIE-IN DW)
C.O.
C.O.
C.O.C.O.
C.O.
EX. 4"Ø S.S.LINE TO MAIN
SEWER
REVISION DATE
PROJ. NO.
PRINT DATE
DWG. DATE
ZE
N
C
Z
A
K
&
P
A
R
T
N
E
R
S
ph
o
n
e
(
2
5
3
)
4
7
5
-
0
3
8
0
e-
m
a
i
l
S
T
U
D
I
O
@
Z
P
A
A
I
A
.
C
O
M
37
2
0
6
t
h
A
v
e
n
u
e
,
S
u
i
t
e
A
Ta
c
o
m
a
,
W
a
s
h
i
n
g
t
o
n
9
8
4
0
6
AR
C
H
I
T
E
C
T
S
,
A
.
I
.
A
.
PROJ. NO.
PZ
A
C
C
AR
C
H
I
T
E
C
T
RE
G
I
S
T
E
R
E
D
39
8
7
BO
L
E
S
L
A
W
Z
E
N
C
Z
A
K
ST
A
T
E
O
F
W
A
S
H
I
N
G
T
O
N
P1.1
PLUMBING WASTE PLAN 00 4 8
PLAN
NORTH 225-3590
11/4/25
225-3590
90
4
Y
E
L
M
A
V
E
.
S
U
I
T
E
A
YE
L
M
,
W
A
11/4/25
TE
N
A
N
T
I
M
P
R
O
V
E
M
E
N
T
F
O
R
:
PE
R
M
I
T
S
E
T
PLUMBING SUPPLY PLAN 00 4 8
PLAN
NORTH
PLUMBING WASTE RISER DIAGRAM