Loading...
HomeMy WebLinkAbout1797 Floor Layout GLSTART LAYOUT 18" DEPTH @ 24" OC TR U S S T O A L I G N W I T H E D G E O F O P E N I N G TR U S S T O A L I G N W I T H E D G E O F O P E N I N G CONTINUOUS 1 3/4" LSL RIM FULL DEPTH TH A C 4 2 2 THA422 AT ALL LOCATIONS U.N.O. 240PLF 240PLF 24 0 P L F QUANTITY HANGER CARRIED MEMBER HANGER SCHEDULE CARRYING MEMBER USE 10DX1 1/2" NAILS @ SINGLE PLY CARRYING MEMBER OR CLINCH 3" NAILS ON BACKSIDE OF GIRDER 6-16DTHA422 TF30 6-10D 01 6-16DTHAC422 TF 6-10D BP02 BP02 BP01 BP01 BP02 BP02 BP01 BP03 BP01 BP01 BP04 BP01BP02BP01 BP01 BP01 F15 F17F16 F0 2 F0 2 F18 F0 6 F0 7 F0 8 F0 9 F0 9 F0 8 F0 9 F1 2 F1 4 F0 3 F01(15) F10(2)F11(4)F13(4) F04(5) 22 - 0 0 - 0 0 6- 1 1 - 0 0 4 - 0 1 - 0 0 15 - 0 0 - 0 0 41 - 0 0 - 0 0 8-00-00 10-00-00 30-00-00 2-00-00 12-00-00 30-00-00 4- 0 0 - 0 0 1 5 - 0 0 - 0 0 43 - 0 0 - 0 0 19-02-00 3- 0 6 - 0 8 11 - 0 5 - 0 8 1- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 8- 0 8 2- 0 0 - 0 0 1- 0 5 - 0 8 2- 0 0 - 0 0 2- 0 0 - 0 0 6- 0 8 1- 1 0 - 0 4 1- 1 0 - 0 4 2- 0 0 - 0 0 2- 0 0 - 0 0 3- 0 8 1- 1 0 - 0 4 1- 1 0 - 0 4 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 2- 0 0 - 0 0 4-00-00 4-00-00 4-00-00 Sultan, WA 98294 BUILDER : PLAN :DESIGNER : CITY, STATE: 5/16/2025 ARLINGTON 360-925-4155 SPANAWAY 253-846-3005 ISSAQUAH 425-391-8000 KINGSTON 425-961-6778 4350852 THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to be incorporated into the building design at the specification of the building designer. See the individual design sheets for each truss design identified on the placement drawing. The building designer is responsible for temporary and permanent bracing of the roof and floor system and for the overall structure. The design of the truss support structure including headers, beams, walls, and columns is the responsibility of the building designer. For general guidance regarding bracing, consult "Bracing of wood trusses" available from the Truss Plate Institute, 583 D'Onifrio Drive; Madison, WI 53179ADDRESS : 1797 A FLOOR TRUSS PLACEMENT LAYOUT N/A APPWRIGHT/ MBA #: NTSSCALE: Century Communities Daisy Plats SALES :PLAT :& LOT Geoff Waits Puget Sound Market Trusses Martha G. DATE : ***ATTENTION**** TRIANGLE SHAPE ▲= LEFT SIDE INDICATOR -RED MARK ON TRUSS IS LEFT SIDE TRIANGLE SHAPE ▲ = INDICADOR DE LADO IZQUIERDO -MARCA ROJA EN ARMADURA ES LADO IZQUIERDO ALL 2X6 STRONGBACKING MUST BE INSTALLED PER ENGINEERING PACKET WARNING:DO NOT INSTALL TRUSSES BACKWARDS OR UPSIDE DOWN. FOLLOW LEFT END INDICATORS ON LAYOUT VERIFY ALL PLUMBING DROPS BEFORE SECURING SHEATHING DO NOT CUT, DRILL, NOTCH OR MODIFY TRUSS MEMBERS WITHOUT PRIOR APPROVAL FROM Builders FirstSource Truss