HomeMy WebLinkAboutPlan 012155 GL Elev B 2021 code Yelm 4-29-2025DESIGNER
BROBST DESIGN WORKS
CONTACT:
DAN BROBST
206.409.6690
dan@brobstdesignworks.com
STRUCTURAL ENGINEER
RB ENGINEERS, INC.
1312 2nd Street, Kirkland, WA 98033
Tel: (425) 822-3009, Fax: (425) 822-2679
Email: RBE1992@ GMAIL.COM
PLAN DESCRIPTION
FLOOR AREA:
MAIN LEVEL:
991 S.F.
UPPER LEVEL:
1164 S.F.
TOTAL:
2155 S.F.
GARAGE:
444 S.F.
FRONT PORCH:
61 S.F.
REAR STOOP:
16 S.F.
OPT. COVERED PATIO:
100 S.F.
SYMBOL AND ABBREVIATION KEY
A.B.
ABV.
A.F.F.
ALT.
AVG
AWN
BLKG.
BM.
B.W.
CFM
DBL
DEPT
DIA
DIM
DISP
DW
EA
E.N.
FP
GALV
GL
GWB
HB
HDR
HORIZ.
LB
MAX.
MECH
MFD
MFR
MICRO
MIN
NTS
ANCHOR BOLTS
ABOVE
ABOVE FINISHED FLOOR
ALTERNATE
AVERAGE
AWNING
BLOCKING
BEAM
BOTH WAYS
CUBIC FEET PER MINUTE
DOUBLE
DEPARTMENT
DIAMETER
DIMENSION
DISPOSAL
DISHWASHER
EACH
EDGE NAILING
FIREPLACE
GALVANIZED
GLUE LAMINATED
GYPSUM WALL BOARD
HOSE BIB
HEADER
HORIZONTAL
POUNDS
MAXIMUM
MECHANICAL
MANUFACTURED
MANUFACTURER
MICROWAVE
MINUMUM
NOT TO SCALE
DETAIL LABEL
CONSTRUCTION DETAIL CALLOUT D
PAGE DETAIL IS LOCATED Si
°-n MEANS THIS PAGE
0/ OVER
CENTURY
COMMUNITIES
16108 ASH WAY SUITE 201 LYNWOOD WA 98087
PLAN 012155 ELEVATION B
2021 CODE - GARAGE LEFT
SINGLE FAMILY RESIDENCE
WOOD FRAME STRUCTURE
STEM WALL /CRAWL SPACE FOUNDATIO
DETACHED RESIDENCE
WITH ATTACHED 2 CAR GARAGE
BUILDING CODE / ENERGY COMPLIANCE
2021 INTERNATIONAL RESIDENTIAL CODE
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL FIRE CODE
2021 WASHINGTON STATE ENERGY
2021 UNIFORM PLUMBING CODE
+ WA. STATE AMMENDMENTS
OX SLIDING WINDOW RIGHT OPERATES WALL BELOW (FLOOR FRAMING AND ROOF PLANS)
O.C. ON CENTER
OH OVERHEAD WALL ABOVE (FLOOR FRAMING)
PIC PICTURE WINDOW — — — — — DROPPED HE ABOVE (FLOOR PLANS)
PLF POUNDS PER LINEAL FOOT
PSL PARALLEL STRAND LUMBER WALL ON FLOOR PLAN
R/A RETURN AIR
REQ'D REQUIRED
R&S ROD AND SHELF SHEAR WALL ON FLOOR PLAN
S.D. SMOKE DETECTOR SW-4 SHEAR WALL TYPE - SEE PAGE S1 FOR FULL INFORMATION
S.F. SQUARE FEET
SG SAFETY GLASS
SHLV SHELVES FLOOR TRUSS
SHWR SHOWER
STD. STANDARD — GIRDER FLOOR TRUSS OR FLUSH BEAM -PER CALLOUT
TB TOWEL BAR
TP TOILET PAPER HOLDER — DROPPED BEAM
TR TOWEL RING
TYP TYPICAL FLOOR JOIST OR ROOF RAFTER
VERT VERITCAL
VTOS VENT TO OUTSIDE F7- — — — 77
W/ WITH 0 11 II PLUMBING FIXTURE ABOVE
WC WATER CLOSET II II
W/D WASHER DRYER [v]
WH WATER HEATER
XO SLIDING WINDOW LEFT OPERATES
OVERFRAME AREA (ROOF PLAN)
DROPPED CEILINGS (FLOOR PLAN)
SECTION LABEL
BUILDING SECTION CALLOUT
A9
PAGE SECTION IS LOCATED
YELM VERSION
ISSUE
6.15.2024 - ORIGINAL 2021 CODE SET
ENERGY CREDITS
SEEPAGE N1.1 FOR SELECTED
CREDITS AND UA ALTERNATIVE PATH
BUILDING TYPE &CLASSIFICATION
BUILDING TYPE: V-B
BUILDING CLASSIFICATION: R3/U
SHEET INDEX I CURRENT DATE
COVER SHEET PLAN INFORMATION 1 6.15.2024
SHEET Al FOUNDATION /MAIN FLOOR FRAMING PLAN I 6.15.2024
UPPER LEVEL FLOOR FRAMING PLAN
SHEET A2 MAIN & UPPER LEVEL FLOOR PLANS 1 6.15.2024
SHEET
A3.1
ROOF FRAMING
PLANS
6.15.2024
SHEET
A5.0
ELEVATIONS -
2-CAR GARAGE
6.15.2024
206.409.6690
dan@brobstdesignworks.com
w
J
w
O
Q
0
I
W
M
O
U
�1
n s
mv--.�
SHEET
A7
SECTION
6.15.2024
ti
co
0
0o
M
o
o
Z
SHEET
E1
MAIN & UPPER LEVEL ELECTRICAL PLANS
4.13.2025
W
- z
—_
o
CV
z
W
SHEET
M1
DUCTWORK PLAN
6.15.2024
w u
co
SHEET
AD1
ARCHITECTURAL DETAILS
6.15.2024
Q
C=
Q
00
0
SHEET
S1
RB ENGINEERS STRUCTURAL DETAILS
6.15.2024
c�
SHEET
S2
RB ENGINEERS STRUCTURAL DETAILS
6.15.2024
SHEET
S3
RB ENGINEERS STRUCTURAL NOTES
6.15.2024
REVISED
SHEET
N1
ENERGY V.I.A.Q & NOTE SHEET
6.15.2024
4.13.2025
SHEET
N1.1
ENERGY COMPLIANCE FORMS
6.15.2024
SHEET
N2
GENERAL NOTE PAGE
6.15.2024
1/4 "= i $- 0"
SCALE
6.15.2024
DALE
PLAN 2155
COMPUTER FILE NAME
COVER.
B
SHEET NUMBER
tk�
A6
0
Lo
o
v,
0
in
00
39'-0"
PT 44 ABOVE OMIT PADS AT PATIO PER OPT.
W/ ABU44 9'-8 1 /2" 12'-11 3/4"
Xu?? -1
- - - - - 0
NIC
241 W/ FIBERMEOSH RE NF.. 24 1�
1 0/ 2" GRAVEL BASE 1
SLOPE AWAY /4 GRADE / FT
21'-7" 4'-6" 12'-11"
F
o
P TYP o 0
� A
S1 N uj
S1 NPF_
S1
1
1-7
0 IL P PL T 1L
"
2x,10 DF#2 IOOISTS @ 1116" O.C. II 11 II II 1
DBL JOIST W/ OPT. II riII II III II II II II II II II II II II II 7' " ,-
ZIII IC)
s III 13 4x10 D� 2 11 �11-1 II II II_ II FU -1II_ II II II 1 Ij
O �_ �I Io II —II —III®g C�IIT�®1� 8 1
AD1 0 I -i EIC21)
W/ OPT. ONLY IE = 6 11L B ACK OLY VAPOR BARRIER HROUGHO T
DBL. JOIST W/ OPT. 1 II II II II II II II II II II II II
210-2 ® DBL III
W OPT. ONLY 1-11-0 1/2" -7" �2')" 2'- LT
A 1
S1 I II
TYP
SIM
4" CONC. SLAB ON GRADE
W/ FIBERMESH REINFORCEMENT
0/ 2" GRAVEL BASE
0/ 6 MIL POLY. V.B.
0/ COMPACTED GRADE
SLOPE TOWARD DOOR
L-
o ���Q�
Lo
I
WS210-2 ® DBL
LUS210 TYP.
SIM II
L
L
CONTROL JOINTS
AS SHOWN
II
L
I _
L — CONT. FOOTING
REFERENCE DETAIL R STHD14—
IN CASE OF MISPLACED S2 eDHOLD-DOWN, TYP.
HTT5 MAY BE USED IN
0 o LIEU OF STHD14RJ
4 3/4"
J
Al 2
S1 M d-
PT 4x4 ABOVE = ui
cm_ _
W/ ABU44 N Ln N N
I w
Ln
/ F_,,J�/ r W/ ABU44
ABOVE
' 22.--------------------[Z4:
4" CONC. SLAB ON GRADE
W/ FIBERMESH REINFORCEMENT
0/ 2' GRAVEL BASE
" " 0/ COMPACTED GRADE
3 1 /4 8, -11 1 /4" 4 3/4 SLOPE AWAY 1/4" / FT
2'-0"
16'-0"
2'-0"
9'-10"
9'-2"
20'-
0"
19,- 0"
39'-0"
FOUNDATION MAIN LEVEL FLOOR FRAMING PLAN
VENTILATION: R408.2 WITH WA. STATE AMMENDMENT
PROVIDE 1 SQFr. VENTILATION PER 300 SQFr. UNDER FLOOR AREA
991 SQFr UNDERFLOOR AREA / 300 = 3.31 SQFr. VENTILATION REQUIRED
3.31 SQ Fr VENTING REQUIRED / .50 SQ Fr PER VENT = 6.62 TOTAL NUMBER
OF 16'x8' PLASTIC VENTS REQUIRED
PROVIDE A MINIMUM OF (7) 16'x8' FND VENTS
(NEr VENTING AREA = 73 SQ IN OR .50 SQFr)
POINT LOAD NOTE:
'PL' DESIGNATES POINT LOAD FROM ABOVE ON THE
FOUNDATION PLAN. PROVIDE SOLID BLOCKING UNDER
ALL LOCATIONS AND NO VENTS ARE ALLOWED BELOW PL
0
i�
0
07
0
2x6 ® 16" O.C. EXTERIOR
WALLS TYP. U.N.O
(2)2x6 HF#2 HDR.,
EE TYP UNO PER
52 I I
II
PROVIDE DRAFT STOPPING @ --L�
THIS TRUSS WALL LINE
R502.12 IRC
FOOTING SCHEDULE:
1- 1'-6"x1'-6"x8" DEEP
FOOTING ()#4 EACH WAY, TYP.
F 2'-O"x2'-O"x8" DEEP
® CONC. FOOTING W/
24 -1 (3)#4 EACH WAY, TYP.
F2'-6"x2'-6"x8" DEEP
® CONC. FOOTING W/
(4)#4 EACH WAY, TYP.
F- -1 3'-0"x3'-0"x12" DEEP
® CONC. FOOTING W/
L36 J (5)#4 EACH WAY, TYP.
—14'-0"x4'-0"x12" DEEP
® CONC. FOOTING W/
48 � (7)#4 EACH WAY, TYP.
3)2x6
PL
�I
Lv-
Ilkl ZIII II
I II II n II
1 )2
I II
L —
PL ABOVE -
EL. B&C
'1
L-Llt�
n
2x4 @ 16" O.C. STUD WALL
TYP
co
Fn
U
3-1/2x9 GL
I I (3) � B&C
III ABOVI
18" DEEP OFEN W FLOOR TRUSSES ® " O.0
PROVIDE CHASEWAY FOR HVA DUC II G
II II II II jl 1
II II II II ZIII
II II
II II
LLI+H II II I�
�, II II II II 1
3-1/2x9 GL
(3 4-/
=]Ifi—-IT 11 1 �--
J L _ _ +H. GIR+ R TRU� _ - - RING W L- -
4 0 DF# (2)2 I 1
1 (3)2x4 1 0 II I
1 L(2)2x6
I I
1 1 c„ I I I I Il G ICI
II PL ABOVE II II I III
(6)2x6 � - - J L � E I
I ELEV. C OVE
PL ABOVE )2
LL I. (3)2x6
(2)2x6 11 II f1 II II
�LEV. OVE
GIRDE II
TRUSS II )2
II
s1 ! II
i II ZIII II IIII II II II II II III
� II
k(3)46 1 I
tc
UI IU UI P IU U
UPPER LEVEL FLOOR PLAN FRAMING PLAN
2x4 ® 24" O.C. INTERIOR WALLS
TYP. U.N.O. EXCEPT AT STAIRWELL
& BEARING TO BE 2x4 ® 16" O.C.
PLUMBER NOTE:
PROVIDE A MINIMUM OF 2" CLEARANCE AT ALL PLUMBING
DRAINS FROM THE EDGE OF FLOOR TRUSSES, TYP.
CONCEALED SPACE NOTE:
PROVIDE DRAFT STOPPING @ CONCEALED FLOOR SPACES
IN EXCESS OF 1000 S.F. R502.12 IRC
EXPIRES 2/1 2024 I
dan@brobstdesignworks.com I
206.409.6690
L~L
uj
Lu
v
L.0
Lo
�
N
�
Z
W
Q
0
J
O
o—
U
00
0
N
DC Z
OJ
O
LL
cod Z
Z �
O
Q LL
C
Z �
O
UL OUL
ti
co
0
co
Q
>-I
O
W
H
Z
J
-
z
r
O
N
W
w
u
cl)
U
Q
�
u3
Q
ao
0
IT -
co
IT -
REVISED
1 /4"=1'- 0"
SCALE
2.8.2021
DATE
2155-P
COMPUTER FILE NAME
Al
SHEET NUMBER
HIGH EFFICIENT HVAC 3.6:
AIR SOURCED HEAT PUMP
MIN. HSPF2 OF 10.0
(HSPF OF 11)
_
CV
0
uo
0
co
o '
in
co
3
HEAT
_ PUMP
�n
r 1
3' SQ. CONC.
OOP W/ OPT.
I
L---1
_
N m
44 WRAPPED POSTS
WITH OPT. COVERED PATIO
9'-7" 13'+O"
6-Ox5l 0 XO
GREAT ROOM
OPTIONAL
—ELEC. FIREPLACE. INSTALL
PER CODE & MFR. SPECS.
17,000 +/- BTU
39'-0"
10'-O"
2-8
OPTIONAL
COVERED PATIO
10'-O"
STEP
CONC.
STOOP
SW-4
10 6-Ox6-10 SGD (SG)
0
-17
2x4 WALL BELOW -
DINING 34-1/2" HIGH
_
4'-1" 2
12'-10"
6'-5"
SW-4
XO _
8'-0" I
I
II o KITCHEN I
z
O w oM O
Ito z �__u I
�>o
II
II F;l
R I
ii
5-2" "
HEAT
SW-4 O CO N
PUMP
H 1-3/4" SOLID -CORE 110v
Z TIGHT FITTING DOOR W/ 1'-10
I w I SHELVES
AD1 20 MINUTE MIN. RATING ow— — —
CN
2-8 W/ S.C. HINGES AND =
ZONAL TO BE SELF -LATCHING I
4" STEEL PIPE BOLLARD ,Y1
EFFICIENT WATER HEATING 5.6: I W o
ELEC. HEAT PUMP W.H HEAT ALARM ❑H N Lj 3 OPT. 2-6/
NEEA TIER III SPECIFIED 110v INTERCONNECT
GARAGE
cc
5/8" TYPE "X" G.W.B.
CC
ON ALL WALLS
AND CEILING, WRAP
EXPOSED POSTS & BEAMS
O.
-0" 16'-0"
• 1 1 1 1
® 1 1
19'-4"
MAIN LEVEL FLOOR PLAN
O DENOTES MIN. 50 CFM EXHAUST FAN., LINO TYPICAL DETAILS NOTE:
ALL FANS MUST VENT TO THE OUTSIDE REFERENCE DETAIL XX PAGE S2 FOR TYPICAL CORNER FRAMING
REFERENCE DETAIL ZZ PAGE S2 FOR TYPICAL OPENING FRAMING
O1 10v DENOTES SMOKE DETECTOR LOCATION
ALL SMOKE DETECTORS TO BE 11 OV. ENERGY & BUILDING LEAKAGE 1 TESTING NOTES:
INTERCONNECTED WITH BATTERY BACK-UP
SEE PAGE N1 FOR COMPLETE INFORMATION
CO CARBON MONOXIDE DETECTOR TO BE 11Ov
WITH BATTERY BACK-UP
SHEAR WALL NOTE: sw_x
REPRESENTS SHEAR -WALL LOCATION AND TYPE,
REFERENCE PAGE S1 FOR SHEAR -WALL SCHEDULE
SAFTEY GLASS NOTE:
(SG) DENOTES SAFETY TEMPERED GLASS
BUNDLED STUD NOTE:
SEE FLOOR FRAMING FOR BUNDLED STUD / POST LOCATIONS
PLUMBING NOTE:
CLOTHES WASHER AND DISH WASHER
MUST BE INSTALLED WITH WATER -HAMMER
PREVENTION DEVICES.
SW_p I I PORCH
39'-0"
FRAMING & ROUGH OPENING NOTES:
-EXTERIOR HINGED DOORS (VERIFY W/ CONTRACTOR)
FURR BOTTOM WITH 3-1/2" x WIDTH x 7/16" OSB
SINGLE DOOR : WIDTH + 2" x 83'
DOUBLE DOOR SET : WIDTH + 3' x 83'
-INTERIOR HINGED DOORS
SINGLE DOOR : WIDTH + 2' x 82-1/2'
DBL. DOOR SET: WIDTH + 2" x 82-1/2'
-BYPASS DOORS: WIDTH - 1" x 83"
-SLIDING GLASS DOOR: WIDTH + 0' x 82-1/2'
PLACE NERVASTROL PLASTIC UNDER DOOR WITH CAULKING UNDER
AND OVER NERVASTROL.
-ALL 8-0 DOORS (FRONT DOOR & FRENCH): WIDTH + 2" x 99"
PROVIDE 2x BLOCKING AT THE FOLLOWING LOCATIONS:
HANDRAIL BACKING 0 32" CENTERLINE
TOWEL BAR BACKING 0 48" CENTERLINE
TOWEL RING BACKING ® 60"
TOILET PAPER BACKING 0 25"
10'-0"
❑0-
3-2 2-7 �iiV
-11"
10-11"
5'-2" 3'-2" 29-
4-0 BP
0110v
BEDROOM 4
EMERGENCY EGRESS PER
NOTE 40 PAGE N2
OPT. GUEST SUITE
lb
0
� O
CV
Ln
r�
Co
i
0
_
0
c
Lr
UPPER LEVEL FLOOR PLAN
FLOOR AREA:
MAIN LEVEL:
991 S.F.
UPPER LEVEL:
1164 S.F.
TOTAL:
2155 S.F.
GARAGE:
444 S.F.
FRONT PORCH:
61 S.F.
REAR STOOP:
16 S.F.
OPT. COVERED PATIO:
100 S.F.
FRAMING & ROUGH OPENING NOTES:
-EXTERIOR HINGED DOORS (VERIFY W/ CONTRACTOR)
SINGLE DOOR : WIDTH + 2' x 83-1/2"
DOUBLE DOOR SET : WIDTH + 3" x 83-1/2"
-INTERIOR HINGED DOORS
SINGLE DOOR : WIDTH + 2' x 82-1/2"
DBL. DOOR SET. WIDTH + 2" x 82-1/2"
-BYPASS DOORS: WIDTH - 1' x 82"
PROVIDE 2x BLOCKING AT THE FOLLOWING LOCATIONS:
TOWEL BAR BACKING 0 48" CENTERUNE
TOWEL RING BACKING 0 60"
TOILET PAPER BACKING @ 25'
FIRE BLOCKING NOTE
PROVIDE FIRE BLOCKING AT THE FOLLOWING LOCATIONS:
- AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL
AND HORIZONTAL SPACES.
- IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS
INCLUDING FURRED SPACES AT THE CEILING AND FLOOR LEVELS
AND AT 10 FT. INTERVALS BOTH VERTICAL AND HORIZONTAL
- IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP
AND BOTTOM OF THE RUN AND BETWEEN STUDS ALONG AND IN LINE
WITH THE RUN OF STAIRS IF THE WALLS UNDER THE STAIRS ARE UNFINISHED
-IN OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, FIREPLACES AND
SIMILAR OPENINGS THAT AFFORD PASSAGE FOR FIRE AT CEILING AND FLOOR
LEVELS, WITH NONCOMBUSTIBLE MATERIALS.
- AT OPENINGS BETWEEN ATTIC SPACES AND CHIMNEY CHASES FOR
FACTORY BUILT CHIMNEYS.
JZM TA��
o
`241 4s
ISTE��1
SSIONAL
EXPIRES 2/1 /2025
dan@brobstdesignworks.com
206.409.6690
L~L
J C/3
W Lo
c� L(-> Z
� Q
CV J
V
LJJ � O
0 j
O O
U 1
CN LL
N
ti
co
0
co
O
Ell
J
— z
N
W
z
w u cup
C/3
U �
Q
co
0
zo
REVISED
1/4 =V_0"
SCALE
6.15.2024
DALE
2155-P
COMPUTER FILE NAME
SHEET NUMBER
Q
m
V)
m
J �
a
w
p
zU
O Z
Y
� o
O J
J m
a x
C'4
p
W J
> o
w LLI
o �
z cl-
Q
m
cn
C/)
J �
Q
w
0
Ln Z
z CD
o z
p Y
�
o
O J
J m
Qx
CV
p
Z J
w p
> cn
w U-i
> 8
o �
z cl-
m
T
GABLE END TRUSS
= =
S1
SIM 1 � o 1 0 5:12 � 5:12 LIC-4
II �_ III
1 /-(2A35TO) -WALLBM. TO WAL BM � I'
202 LEDGER W/ (5)16d ® 16" O.C.
TO EACH STUD
& 16d ® 4" O.C. TO 2x BLOCKING
BETWEEN STUDS
SIM
;T
p
w
0
J
a
Ln
z
w
uj
44 PT POST W/
ACE4 CAP, TYP.
(3)2x6 (3)2x6 J
2x10 LEDGER W/ (4)16d ® 16" O.C.
& 16d @ 4" O.C. TO 2x BLOCKING
BETWEEN STUDS
- RJ
F III II fv1MMSSES II II
S1
TYP - - 0 24" O.C.
�Q
III a II II II II II
M
)2x4,
(3)2x4 III II II II (Ia��ll
3-1 lqxl2 GIL (FULL IWIDTH) _[L
p S1
s1 TYP
JQ�\� N RJ
N 5:12 0 R 5:12 oI
LL_
en- -
I 00
I � GABLE END TRUS I
SAVE VENTS ALLOWED AT THIS R00
LOWER ROOF FRAMING PLAN
4 3/4"-
(2)2x6
HUC48
PT 44 POST
TYP
a
(2)A35 BM.
TO POST, TYP.
INSULATION NOTE:
FILL TRUSS CAVITY AS MUCH AS POSSIBLE
AT PINCHED AREAS OF TRUSSES MAINTINING
A 1" MINIMUM AIR SPACE ABOVE WITH BAFFLES
& ADD ADDITIONAL INSULATION IN AREAS WITH
MORE SPACE AVAILABLE TO COMPENSATE FOR
THE LESSER AREAS, TYP. BOTH AT SCISSOR
AND STANDARD TRUSSES.11_0"
2x6 ® 16" O.C. EXTERIOR WALLS
TYP. U.N.O
s1 TYP
TYP
2x4 @ 24" O.C. INTERIOR WAL
TYP. U.N.O. EXCEPT AT STAIRWE
TO BE 2x4® 16" 0.
ATTIC VENTILATION:
MINIMUM ATTIC VENTILATION SHALL BE 1/300 OF THE ATTIC PLAN AREA.
UPPER VENTING SHALL BE PROVIDED BY
AF-50 ROOF JACKS LOCATED ABOVE THE MIDPOINT OF THE ROOF
WITHIN 3'-0" OF THE RIDGE LINE
EACH JACK VENT PROVIDES .34 SF OF VENTING PER JACK
LOWER VENTING SHALL BE PROVIDED BY
LOWER VENTING SHALL BE EAVE VENT BLOCKS W/ (4) 2" DIA SCREENED HOLES
AND / OR AF-50 ROOF JACKS LOCATED AS SHOWN
EACH JACK VENT PROVIDES .34 SF OF VENTING PER JACK
MAINTAIN 1" CLEAR AIR -SPACE ABOVE INSULATION AT EAVES
PROVIDE ROOF JACKS FOR SUPLIMENTAL VENTILATION AS REQ'D BY CALCS.
PROVIDING A NET VENT AREA OF 7.068 SQIN.=0.0492 SQ FT
NOTE: IF FOR ANY REASON THE HOUSE IS PLACED 5'-0" OR CLOSER TO THE
PROPERTY LINE, EAVE VENTS ARE PROHIBITED AND ARE TO BE SUBSTITUTED
ROOF JACKS PLACED BELOW THE HALF WAY POINT. BAYS TO BE FILLED WITH
TIGHT FITTING, 2x BLOCKING.
RJ DENOTES ROOF JACK LOCATION
-ROOF COVERING SHALL BE ANCHORED AND DESIGNED FOR HIGH WIND
AND DRIFTING SNOW.
UPPER ROOF:
1198.0 SQ. FT ATTIC AREA / 300 = 4.0 SQFT. VENT'G REQ'D
2.00 SQFT. OF VENT'G TO BE PROVIDED ABOVE THE HALF -WAY POINT AND
2.00 SQFT. OF VENT'G TO BE PROVIDED BELOW THE HALF -WAY POINT.
UPPER VENTING:
2.00 SQ. FT. / .34 PER VENT = 5.88 : PROVIDE (6) ROOF JACKS
LOWER VENTING:
(30) MAX. EAVE VENTS : (30) x .049 PER VENT = 1.47 S.F.
2.0 SQ. FT. - 1.47 SQ. FT PROVIDE _ .53 REMAINING
.53 SQ. FT. / .34 PER VENT = 1.55 PROVIDE (2) ROOF JACKS
LOWER ROOF:
296.0 SQ. FT ATTIC AREA / 300 = .99 SQFT. VENT'G REQ'D
.50 SQFT. OF VENT'G TO BE PROVIDED ABOVE THE HALF -WAY POINT AND
.50 SQFT. OF VENT'G TO BE PROVIDED BELOW THE HALF -WAY POINT.
.50 SQ. FT. / .34 PER VENT = 1.47 : PROVIDE (2) ROOF JACKS
LOWER VENTING:
.50 SQ. FT. / .049 PER VENT = 10.5 : PROVIDE (11) EAVE VENTS
OPT. PATIO ROOF:
100.0 SQ. FT ATTIC AREA / 300 = .34 SQFT. VENT'G REQ'D
.17 SQFT. OF VENT'G TO BE PROVIDED ABOVE THE HALF -WAY POINT AND
.17 SQFT. OF VENT'G TO BE PROVIDED BELOW THE HALF -WAY POINT.
UPPER VENTING:
.17 SQ. FT. / .34 PER VENT = .5 : PROVIDE (1) ROOF JACKS
LOWER VENTING:
.17 SQ. FT. / .049 PER VENT = 3.47 : PROVIDE (4) EAVE VENTS
m
J �
J ~
w
0
v, z
z
o Z
Y
LLj U
o
o m
J x
CV
Z p
W J
> O
Ln
>w
im
CD�
z �
PROVIDE STC CLIP CONNECTION AT
TOP PLATE OF ALL NON -BEARING WALLS
TO BOTTOM CHORD OF TRUSS. INSTALL
PER MFR.'S INSTRUCTIONS, TYP.
TYP
CONT. METAL GUTTER, TYP.
DS
-1L2x
GL
4x
DF 2
48
DF 2
DS
II
(2)
2.5
III II
II
I
II II
II
(3)2�6
3)2x6
II II II II
II
II III (3)2x
(2)H2%
N
III N II
II
II II
�Q
N
"'
MFID. TRUStES II II
II
II III �
I
�-�
0
24"0
�U
II
A PROVE,
_ V) _
w
"' N
-
_
w
AFTEY�ANCHO
®
o
II II II II
- -
II III o
III II
RJ II
❑
RJ
RIDGE
RJ
R�J
'YiJ
RJ
_ �
II II II II II
II
I
LOW
I
_
III II
007
I�n\��MII
II II
�Q
III II
II II II II
-
(3)2x61
=
_
x8
F#2
(2)H2
III II
II II II II
GIRDER TuU S11 lu
TYP
lL�f1L.J
LOW
RJ 5LTJ
TYP
DS
TYP. OVERFRAME NOTE:
PROVIDE 2x6 HF#2 @ 24" O.C. RAFTER & RIDGE
BRACE TO TRUSSES BELOW W/ 2x4 BRACE @ 48" O.C.
EACH WAY, EACH MEMBER, TYP. ALL CONNECTIONS PER
MINIMUM NAILING REQUIREMENTS OF IBC TABLE 2304.10.1
ALL END MEMBERS SHALL BE SCREWED TO FRAMING
BELOW W/ 1 /4"x4-1 /2" SDS SCREWS @ 12" O.C.
PROVIDE CONT. ROOF SHEATHING UNDER OVERFRAME
PROVIDE 22"x3O" ACCESS OPENING
UPPER ROOF FRAMING PLAN
TABLE R03.2.1(1
EXTERIOR WALLS
EXTERIOR WALL ELEMENT
MINIMUM
FIRE -RESISTANCE RATING
MINIMUM FIRE
SEPARATION DISTANCE
WALLS
FIRE -RESISTANCE RATED
1HOUR- TESTED IN ACCORDANCE WITH ASTME 119
OR UL 263 WITH EXPOSURE FROM BOTH SIDES
< 5 FEET
NOT FIRE -RESISTANCE RATED
0 HOURS
> OR = 5 FEET
PROJECTIONS
NOT ALLOWED
N/A
< 2 FEET
FIRE -RESISTANCE RATED
1 HOUR ON THE UNDERSIDE °' b
> OR = 2 FEET TO < 5 FEET
NOT FIRE -RESISTANCE RATED
0 HOURS
> OR = 5 FEET
OPENING IN WALLS
NOT ALLOWED
N/A
< 3 FEET
25% MAXIMUM OF WALL AREA
0 HOURS
3 FEET
UNLIMITED
0 HOURS
5 FEET
PENETRATIONS
ALL
COMPLY WITH SECTION R302.4
NONE REQUIRED
< 3 FEET
3 FEET
N/A = NOT APPLICABLE.
a. ROOF EAVE FIRE -RESISTANCE RATING SHALL BE PERMITTED TO BE REDUCED TO 0 HOURS ON THE UNDERSIDE OF THE EAVE IF
FIREBLOCKING IS PROVIDED FROM TEH WALL TOP PLATE TO THE UNDERSIDE OF THE ROOF SHEATHING.
B. ROOF EAVE FIRE -RESISTANCE RATING SHALL BE PERMITTED TO BE REDUCED TO 0 HOURS ON THE UNDERSIDE OF THE EAVE
PROVIDED THAT GABLE VENT OPENINGS ARE NOT INSTALLED.
DS
GABLE END TRUSS
(2)2x6 HF#2 HDR.
TYP UNO PER
TYP
H
S1
TYP
TYP
m
U)
J �
Q
w
0
z CD
O Z
p Y
uj o
O J
J m
Q x
N
W �
> O
co
>W
cm
Z �
SIM TA��
24149
IST IQ
o� S ONAL � 1
EXPIRES 2/1/2025
• a
dan@brobstdesignworks.com
206.409.6690
W Q
J _I
�W LLo �
v r V
p� N
Q V.-
CD-
' Z �
W Q
0 o LL.
CU
'Ir- LL.
0 0CN O
co
O
co
Q
O
W Z
H J 14
z r
N
w
W u c/)
Q
U �
2
cn
Q
ao
O
IT-
C)
REVISED
1 /4"=1,_0„
SCALE
6.15.2024
DA IE
2155-P
COMPUTER FILE NAME
A31
1
SHEET NUMBER
LEFT SIDE ELEVATION PLAN 2155 - ELEVATION B
RIGHT SIDE ELEVATION
�oo�oo�❑❑
00 00
00
REAR ELEVATION
[K�l�ll�lyrl:[il��yal�[el��:�iI�l�l�[r
II1300610L10�101iII�1e31�11111�Ic
5/48 BAND W "Z" FLASHING
P. BAND TRIM
2x8 BARGE BOARD W/
GALV. EDGE FLASHING
PROVIDE "Z" FLASHING AT ALL
HEAD TRIM LOCATIONS
5/44 WINDOW TRIM, TYP.
5/44 CORNER BOARDS, TYP.
CONT. METAL GUTTERS
DOWNSPOUTS PER ROOF PLAN
(2x6 FASCIA FRONT ELEVATION)
FIBER CEMENT SIDING
8" EXPOSURE +/— PER MFR.
SLOPE FINISHED GRADE AWAY
FROM HOUSE 1/4" / FT.
5/4 WOOD WRAP POST
5/44 TOP TRIM &
5/46 CEDAR BASE TRIM HOLD UP
1/4" ABOVE CONC., CAULK W/ BACKER ROD
5/46 GARAGE TRIM, TYP.
dan@brobstdesignworks.com
206.409.6690
LL
LJJ
J
LLJ LL m
� z
Q N O
7 Q
M Q Lu
O Lu
U
0
N
ti
00
0
00
a�
�—I O
� O
w z
J
'a (p
N
W
Wuu c/)
Q
U �
Q
0o
lir-
co
REVISED
1/4 1 0"
SCALE
6.15.2024
DALE
PLAN 2155
COMPUTER FILE NAME
-A5
SHEET NUMBER
ROOF CONSTRUCTION
COMPOSITION ROOF ON 30# FELT o/
7/16" OSB o/
2X RAFTERS OR PRE -MANUFACTURED TRUSSES o/
R-60 INSULATION, R-23 MIN. AT EAVES
1/2" G.W.B. CEILING
co
R
bo
CA
EXTERIOR WALL CONSTRUCTION
SIDING o/
7 1/2# FELT OR BREATHABLE HOUSE -WRAP o/
7/16 OSB o/
2x6 STUDS PER PLAN
R-23.0 INSULATION w/ V.B. o/
1/2" G.W.B.
WINDOWS U VALUE = 0.25
SECTION AA
FLOOR CONSTRUCTION
FINISH FLOOR o/
22/32" T & G OSB o/
JOISTS / TRUSSES PER PLAN o/
R-38 INSULATION ABOVE NON -HEATED AREAS
STAIR CONSTRUCTION
2x12 STRINGERS
1-1/8" ENGINEERED WOOD TREADS
1/2" GWB ® USEABLE
SPACE UNDER STAIRS
FIREBLOCK BETWEEN STUDS
ALONG RUN AND ® MID POINT
BETWEEN STRINGERS
R-10 RIGID INSULATION AT 4x HEADERS
PREMANUFACTURED ROOF TRUSSES PER PLAN
R-60 INSULATION, R-23 MIN. AT EAVES
1/2 G.W.B. ® INTERIOR WALLS & CEILINGS
R-23 INSULATION, TYP. ALL EXTERIOR WALLS
18" MANUFACTURED OPEN WEB FLOOR TRUSSES
5/8" TYPE "X" DRYWALL ON
NLL WALLS, POSTS, BEAMS & CEILING
N GARAGE, TYP.
3/4" T&G PLWYOOD, GLUE & NAIL
R-38 INSULATION MAIN FLOOR &
UNDERSIDE OF UPPER FLOOR 0 GARAGE
SEE DETAIL Q/AD1 FOR CRAWL INSULATION DETAIL
2x FLOOR SYSTEM PER PLAN
4" PERF. DRAIN PIPE W/
FREE DRAINING MATERIAL
FILTER FABRIC COVER
CONNECT TO STORM SYSTEM
6 MIL BLACK POLY VAPOR BARRIER
dan@brobstdesignworks.com
206.409.6690
W
J
LLJ Lo
v Lo
044
Q r z
' Z
Lu Q U
cl J w
O C!)
U
N
O
N
ti
00
O
00
O
�—I O
� O
w z
N
w
wo
Q
U �
Q
co
0
REVISED
1/4 1 0"
SCALE
6.15.2024
DALE
PLAN 2155
COMPUTER FILE NAME
_A7
SHEET NUMBER
I GREA� ROOM
I
OPTIONAL II
ELEC FIREPLACE. INSTALL L
RAISE TO
PER CODE & MFR. SPECS. +78" W/ FIREPLACE
17,000 +/- BTU L
6
I /
I
W/ OPT.
+r-0"
A.F.F. \
6
0
OPT. COVERED PATIO
LIGHTS W/ COVER OL
(OMI+7)V/„OPT.)
A.F.F.
HEAT ALARM H❑
110v INTERCONNECT
O.H.D OU ET
OPENER � \
GARAGE
PROVIDE (1) 40 AMP
EV CHARGER IN GARAGE
PER R309.6 (WSBC)
MAIN LEVEL ELEC. PLA_N
DINING
mypp
I/
O CO I
110v
/PORCH
qp
KI HEN
13A--
GFI
II
Z
W O
II
4
II
IIGF
C.D
Ell
E1
4
wjLJ
ii
OPT. GUEST SUITE
2021 CODE NOTES
ALL OUTLETS TO BE PLACED PER CODE AND
IN AREAS AS REQUESTED BY CONTRACTOR
DENOTES MIN. 50 CFM EXHAUST FAN., UNO
ALL FANS MUST VENT TO THE OUTSIDE
1 10v DENOTES SMOKE DETECTOR LOCATION
ALL SMOKE DETECTORS TO BE 110V.
INTERCONNECTED WITH BATTERY BACK-UP
LOCATED NOT LESS THAN 3' FROM ANY BATHROOM
CONTAINING A BATHTUB OR SHOWER
CO CARBON MONOXIDE DETECTOR TO BE 110v
WITH BATTERY BACK-UP
ANY RECESSED LIGHT FIXTURE IS TO
VERIFY POWER NEEDS HAVE PROPER PROTECTION SO THAT
FOR VENT HOOD THE FIXTURE WILL NOT BECOME OVERHEATED
(SEE PAGE N1 AND N2 FOR ADD'L INFORMATION)
- HVAC CONTROLS WITH PROGRAMMABLE SCHEDULE PER
WSEC 403.1.1
- ALL PERMANENTLY INSTALLED LIGHTING
FIXTURES SHALL BE HIGH -EFFICACY PER R404.1
R404.2: ALL PERMANENTLY INSTALLED INTERIOR LIGHTING
FIXTURES SHALL BE CONTROLLED WITH EITHER A DIMMER,
AN OCCUPANT SENSOR CONTROL OR OTHER CONTROL THAT
IS INSTALLED OR BUILT INTO THE FIXTURE.
EXCEPTIONS WHERE NOT REQUIRED:
- BATHROOMS
- HALLWAYS
- LIGHTING DESIGNED FOR SAFETY OR SECURITY
R404.3: ALL PERMANENTLY INSTALLED EXTERIOR LIGHTING
POWER GREATER THAN 30 WATT SHALL COMPLY
WITH THE FOLLOWING:
1. CONTROLLED BY A MANUAL ON AND OFF SWITCH WHICH
PERMITS AUTOMATIC SHUT-OFF ACTIONS.
EXCEPTION: LIGHTING SERVING MULTIPLE DWELLING UNITS
2. LIGHTING SHALL BE AUTOMATICALLY SHUT-OFF WHEN
DAYLIGHT IS PRESENT AND SATISFIES THE LIGHTING NEEDS.
3. CONTROLS THAT OVERRIDE AUTOMATIC SHUT-OFF
ACTIONS SHALL NOT BE ALLOWED UNLESS THE OVERRIDE
AUTOMATICALLY RETURNS AUTOMATIC CONTROL TO IT'S
NORMAL OPERATION WITHIN 24 HOURS
WSEC R402.4.4 : ALL ELECTRICAL AND COMMUNICATION
BOXES INSTALLED IN THE THERMAL ENVELOPE TO BE
AIR -SEALED AND LABELED "NEMA OS4" OR OS 4"
UPPER LEVEL ELEC. PLAN
ELECTRICAL LEGEND
STANDARD SWITCH
WP
WEATHER-PROOF DUPLEX OUTLET
3
TWO-WAY SWITCH
CO
CARBON MONOXIDE DETECTOR
D
DIMMER SWITCH
®
SPECIAL PURPOSE CONNECTION
CEILING MOUNT FIXTURE
EXHAUST FAN
E
HIGH EFFICACY WALL LIGHT
WHOLE HOUSE FAN
PENDANT LIGHT FIXTURE
b
TELEPHONE JACK
HIGH EFFICACY CELING LIGHT
MF
MULTI -FUNCTION JACK
DIRECTIONAL RECESSED CAN
0
TELEVISION (CO -AXIAL CABLE)
WALL MOUNTED FIXTURE
0
NETWORK DATA JACK
-��-0
SMALL BAR LIGHT
T
REMOTE BUTTON
n n n��
LARGE BAR LIGHT
OT
THERMOSTAT
®
UNDER CABINET LIGHTS
b
DOOR BELL RINGER
110v DUPLEX OUTLET
o
PHOTO -EYE AT GARAGE DOOR
6
220V OUTLET
G)110v
SMOKE DETECTOR W/ BATTERY BACK-UP
6GFI
110v GFI DUPLEX OUTLET
HALF -HOT DUPLEX OUTLET
CENTER OVER SINGLE
SINK IF DOUBLE IS
NOT SELECTED
dan@brobstdesignworks.com
206.409.6690
U— z
UJ Q
J J
� J
r
Q O
� U
w Q 0:0.00
0 J
0 �U
U W
CN
O J
c%4 W
ti
co
O
co
O
0
H J
— z
N
ZW
wo
Q
U �
co
O
Cfl
REVISED
4.13.2025
8.29.2025
1/4 "=V-0"
SCALE
6.15.2024
DATE
2155-P
COMPUTER FILE NAME
El
SHEET NUMBER
F_
iF
IlTll 11 11111 11 11 T
III II I III I�I� II III
II II � II
I�
I II II LLIII II
ALL DUCTWORK TO BE LOCATED ON THE
WARM SIDE OF INSULATION WITHIN FLOOR
CAVITY, TYP.
DUCT -WORK LAYOUT IN UPPER FLOOR FRAMING
i--
RETURN AIR PLAN
18"0 FLEX LINE TO FURNACE
b K 1108 DST
dan@brobstdesignworks.com
206.409.6690
L~L
J
z
(7 Lo J
N �
Q r
C7 O fro
I Z O
Lu Q
o J�
0 U
U �
0
N
O
N
ti
00
0
00
o�
Q
�-I O
W z
H J
— zr
N
r
W
W u cn
Q
U �
cn
Q
00
0
IT -
REVISED
1 /4n=1,_ O„
SCALE
6.15.2024
WE
2155-P
COMPUTER FILE NAME
m 1
SHEET NUMBER
FLOOR MEMBER PER PLAN
_— __---
HEADER
OSB SHEATH II WINDOW II
OP ING
II
OSB SHEATH
I NDOW
GH OP ING
I I
A3 CLIP EA. STRINGER 11$"
NIIGH
II II
I I
W/5 TICO NAILS
II II
I I
1 x KICKBOARD U.N.O
II SILL II
I s'LL I
CARPET &PAD 1$" 10" MIN
dan@brobstdesignworks.com
II II
II II
01
206.409.6690
AFTER SILL STRIP IS IN PLACE, ATTACH JAMB STRIPS INSIDE OF
ATTACH A SILL STRIP OF FLASING MATERIAL AT LEAST 12" WIDE
10
WITH THE TOP EDGE EVEN WITH THE TOP EDGE OF THE ROUGH
OPENING AT LEAST 12" WIDE WITH INSIDE EDGE OF FLASHING EVEN
10 .�
SILL. EXTEND THIS SILL STRIP AT LEAST 12" BEYOND THE EDGE
WITH EDGE OF WINDOW OPEINING. START JAMB STRIPS 1" BELOW
`
OF THE ROUGH OPENING FOR WINDOW. ATTACH FLASHING WITH
THE SILL STRIP AND EXTEND JAMB STRIPS 6" ABOVE THE LOWER
1-1/8" BULLN05E
GALVANIZED ROOFING NAILS OR RUST -RESISTANT STAPLES.
EDGE OF THE HEADER TOP OF WINDOW OPENINGS.
GARAGE DOOR
`. PLYWOOD TREADS
��
"SUPER 60" 1 HOURX1
FORTIFIBER SK
PERMEABLE BLDG. PAPER
` \�`��
FLASHING
STOP BLOCK
a
2x6 TRIM
a
WINDOW FLANGE
171
_- -
5/4x4 CORNER BOARDS
x4 TRIM
2x6 CLEAT \� . M
\�
W
HORIZONTAL LAP SIDING
�
z
_ _____ __
SIDING PER ELEVATIONS
C3)2x12 STRINGERS �`�
W/ 2x4 STRONG -BACK `.
Q
-
O.S.B SHEATHING
O.S.B SHEATHING
3/4" PLYWOOD RISERS
O 0
SINGLE LAYER AT
APPLY A BEAD OF CAULKING TO THE BACK SURFACES OF THE
STARTING AT THE BOTTOM OF THE WALL (SOLE PLATE), LAY
1/2" TYPE G.W.B.
WATER RESISTANT PAPER UNDER THE SILL STRIP. CUT ANY
2x4 BLOCK
WINDOW, THEN PLACE THE WINDOW INTO THE ROUGH OPENING
EXCESS WATER RESISTANT PAPER THAT MAY EXTEND ABOVE
WITH FLANGES OVER THE INSTALLED FLASHING STRIPS. AFTER
WINDOW IS PLACED, INSTALL THE HEAD FLASING OVER THE
THE SILL FLANGE ON EACH SIDE OF THE OPENING, (SHOWN IN
A3 CLIP EA. STRINGER
DIAGRAM AS SHORT DASHED LINES), INSTALL SUCCEEDING
W/5 TICO NAILS
WINDOW FLANGE. THIS IS ANOTHER STRIP OF FLASING AT
LEAST 12" WIDE.
COURSES OF WATER RESISTANT PAPER OVER JAMB AND HEAD
FLANGES IN SHINGLE-BOARDW
uj
A
WINDOW FLASHING DETAIL
NONE
B
CORNER TRIM DETAIL
C
DGE DETAIL @ GARAGE DOOR
11-1/2 n
F
TYPICAL STAIR DETAIL
3/4" =1'
1-1/2" =19
=1y
W
U
INSULATION PER PLAN
1�
STUD WALL PER PLAN
GYP. BOARD
7/16" O.S.B OR
UPPER AF-50 ROOF JACK
SIDING PER ELEVATIONS
1/2" CDX PLYWOOD
LOCATED WITHIN 3'-0" OF RIDGE
(OPT. PRESSURE TREATED)
(2)LAYERS GRADE D
SEE ROOF PLAN FOR QUANTITY AND LOCATION OF JACKS
12" MIN.
2" MAX, 12 M N.
BUILDING PAPER WEATHER
RESISTANT BARRIER
ATTIC INSULATION PER PLAN
2x10 FLAT BLK'G
INSTALL BAFFLES AT ALL RIM VENTS
HARDWOOD HAND -RAIL CONTINUOUS &
CORROSION RESISTANT
LOWER AF-50 ROOF JACK
VENT PER PLAN TO BE INSTALLED AT A 30' ANGLE
PER WSEC 40.2.7 #2
PARALLEL TO
(GALVANIZED) METAL LATH
LOCATED IN THE BOTTOM HALF
HANDRAIL
OF THE ROOF, MIN. 2" CLEARANCE
ABOVE INSULATION
SIMULATED STONE VENEER
(ADHERED)
ROOF TRUSS AND SHEATHING PER TYP.
00
TYPE "N" MORTAR JOINT
AND SEATING BED
SOLID 2x BLKG.
SOLID BRASS HANDRAIL
III=III=III=III :.. ' PROVIDE LOOSE STRING LINE
BRACKETS- ATTACH TO
WALL W / LAG BOLTS
26 GA. GALVANIZED CORROSION -
''-III-III-II1=1II TO SUPPORT INSULATION
=1 1=111=1TI1-I
TO BLOCKING. PROVIDE
RESISTANT WEEP SCREED. OVERLAP
BUILDING PAPER, LATH TO COVER °
~
' 11=111=11 =III
III -III -III -II
-III-III-111 '' '
METAL SLEEVES AT
LAG BOLT ATTACHMENT
I
& TERMINATED ON FLANGE00
ONLY NATURAL STONE OR
co
LI=111
NOTE:
Q
11=111 =
HANDRAIL SHALL BE CONTINUOUS THE FULL
MANUFACTURED STONE DESIGNED
LENGTH OF THE STAIRS. ENDS SHALL TERMINATE
FOR GROUND CONTACT TO EXTEND
-III =__------
TIII=III=III-III-III
1II-1 I I-1 I I- '
IN NEWEL POSTS, SAFETY TERMINALS OR QUARTER TURN TO WALL
BELOW GRADE
p
DISTANCE OF GRADE TO SIMULATED
Q
STONE PER MANUFACTURER'S SPECS.
�/ W
I...I J
G
INSULATION BAFFELS @ RIM VENTS
3/4" = 1,
H
HANDRAIL AT WALL
NONE
R
ADHERED STONE VENEER DETAIL
SS
ROOF VENT DIAGRAM
3/4" =1'
,"=,�_o"
w
4" MIN, 12" MAX.
W u c/)
SIDING PER ELEVATIONS
GYPSUM WALL BOARD
1" CLEARANCE ABOVE FLASHING
WOOD STUDS &
1/4"x2-1/2" LAG BOLTS
Q
U
Z CORROSIVE
FLASHINGRESISTANT
WALL INSULATION
2
co
EDGE OF THERMAL ENVELOPE
Q
HEAD TRIM ��
TOP OF INSULATION TO BE
IN CONTACT W/ BOTTOM OF
o0
C=>
BOTTOM EDGE OF JOIST
FLOOR SHEATHING
cr
fl
��
WINDOW PER PLAN
R-38 FIBERGLASS BATT
INSULATION
4" DIA. STEEL PIPE
LISTED AND RECOGNIZED SESMIC STRAPPING
EQUALLY SPACED CIRCLING TANK FROM BOTH SIDES WATER HEATER
1" CLEARANCE ABOVE FLASHING
0
FLEXIBLE WATER CONNECTIONS
CORROSIVE RESISTANT
"Z" FLASHING
rn No o
�
MIS m
°
° 4
M
CONC. SLAB
FLEXIBLE WATER CONNECTIONS
TRIM BAND PER ELEVATIONS ��
.°: BOTTOM EDGE OF FIBERGLASS BATT
REVISED
=I11=111=1I1=111=1 . PROVIDE LOOSE STRING LINE
UPPER STRAP TO BE LOCATED WITHIN
I_I IIIII111 �, TO SUPPORT INSULATION
TOP 1/3 OF TANK
OSB SHEATHING
-I 11=1 11=1
I11=11I .
a ° °
-ITI-1
-_JTI =III a
_i <, � ° A�
WATER HEATER
1" CLEARANCE ABOVE FLASHING
-11 III=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=� i �_"-- `� 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11=1 11-
II it -I I1=1I1=1I1=1I1=1TI li I1= '- I III -III -I I1=1I1=1I1=1I1=1I1=1I1=1I1=1I ,I I1-
-I 11-1 11=1 11-1 11=1 I I_ �-1 11-1 I I-1 11=1 I I-1 I I-1 11=1 11=1 I I -I T i-
o
PPROVED AND RECOGNIZED SEISMIC STRAPS
SCALE
CORROSIVE RESISTANT
_ _ _ _ _ —
a
BOTTOM STRAP TO BE LOCATED WITHIN
"Z" FLASHING
PARALLEL W/ JOISTS PERPENDICULAR W/ JOISTS
CONC. FOOTING M
4HECBEARANCE OTTOM 1/3
ANY �CONTROLSNG
6.15.2024
DALE
BELLY BAND PER ELEVATIONS
APPROVED WATER TANK STAND
Q
8"
MIN 18" ABOVE GARAGE SLAB
2021 CODE
FILE NAME
°f]COMPUTER
FLASHING IS REQUIRED ABOVE ALL
ALL PROJECTING EXTERIOR TRIM
CONC. SLAB
W
7" FLASHING DETAILS
Q
R-38 UNDERFLOOR INSULATION SUPPORT
Y
STEEL PIPE BOLLARD - BUMPER GUARD
Z
WATER HEATER SEISMIC STRAPPING
SHEET NUMBER
3/4" = 1'
3/4" =1'
16d @ 3" O.C. STAGGER
8d @ 6" Q.C.
2x6 P.T. MUDSILL W/ A.B. FULL WIDTH 2x P.T.
PER SHEARWALL SCHEDULE SHEATHING EDGE NAILING MUDSILL W/ A.B.
12" MIN. AT MUDSILL ENDS & TO EA. STUD, TYP. PER SHEARWALL SCHEDULE SHEATHING EDGE NAILING
JOINTS, WITH 7" MIN. EMBED. W/ CONT. SHEATHING TO SILL " TO EA. STUD, TYP.
12 MIN. AT MUDSILL ENDS &
3"x3"x1/4" PLATE WASHERS (2)2X6 AT HOLD-DOWN JOINTS, WITH 7" MIN. EMBED. W/ CONT. SHEATHING TO SILL
STHDRJ HOLDDOWN, FILL ALL 3"x3"x1/4" PLATE WASHERS
FLOOR JOIST PER PLAN NAIL HOLES TO DBL. STUD (22X6 AT HOLD-DOWN
AT STRAP LOCATION (PER PLAN) TOP FLANGE HANGER D HOLDDOWN, FILL ALL
OPT: GLUE JOIST IN HANGER NAIL HOLES TO DBL. STUD
EDGE NAILING (HANGER W/ TYP. SHEATHING AT STRAP LOCATION (PER PLAN)
PER S.W. SCHED.
2x10 RIM BOARD ADHESIVE TO REDUCE 16d @ 3" O.C., STAGGER
w SQUEEKING NOT REQUIRED) 8d @ 6" O.C. o
EDGE NAILING () FLOOR JOIST PER PLAN z
z EDGE NAILING
PER S.W. SCHED. J PER S.W. SCHED. a
Ib z m00 z Ib z
GRADE = FINISH D0 w X
x a (2)LAYERS OF GRADE- - Q
W W 30# FELT BETWEEN ° 1=III=� a
- _ Z
� � III
z J � WOOD AND CONC. = �= � I- a � � o
-III-_-#4 CONT. @ TOP a J 0 _ �� z 2 I
HOOK VERTICAL REBAR, I aQ =- - T o a Y HOOK VERTICAL REBAR, - _-#4 CONT. @ TOP J - 0 0
ALTERNATE SIDES _#4 @ 24 OC I -_—III= #4 @ 24 OC o co a YLL_ w
I I I III— VERT. @ CL OF WALL - 1 z a � ALTERNATE SIDES I III = _ I 1 m v
6 MIL. BLACK _ _ N m VERT. @ OF WALL - N Z) m
-III=III=TYP. 6 MIL. BLACK =III —III —II =
POLY VAPOR BARRIER I POLY VAPOR BARRIER I -III=III=NP'-111-11 '1
UNYIELDING SOIL e L. 00 Q UNYIELDING SOIL a L I I M 11- 00
III I I- Ld=1 1- w
"'-1II-1I1= II=1II=1 1 w - w
4 HORIZ. BARS- _ X-111-111-111— 1 3„ (2)#4 CONT. BOTTOM 4 HORIZ. BARS- - (2)#4 CONT. BOTTOM
@ 10 O.C., TYP UNO GR. 40, TYP. @ 10' O.C., TYP UNO 3 6' 3
GR 40 TYP
V-0"
NOTE: FOR UNBLANCED BACKFILL
a. OF 2'-7" - 4'-0" USE
ALTERNATE FOOTING DESIGN
° Q e.
4„ 8„ 4"
1'-4" or 4 ALTERNATE FOOTING
EXTERIOR SHEARWALL @ CRAWL SPACE
3/4"=1'-0" JOISTS ON TOP OF STEM WALL
2x6 P.T. MUDSILL W/ A.B. v
PER SHEARWALL SCHEDULE
PLY. EDGE NAILING
® HOLDOWN STUD
12" MIN. AT MUDSILL ENDS &
JOINTS, WITH 7" MIN. EMBED. W/
(2)2x STUDS
3"x3"x1/4" PLATE WASHERS
AT HOLD-DOWNS
#4 CONT.
EXPANSION
S D14
JOINT
w 38-2 1/ 2x .148
NAILS o
STRAP LOCATION uJ
PER PLAN z
° e '4
e• ° •�d. ,.
FINISH EDGE NAILING a
a
GRADE
z
-
Q
"�:.
#4� 0 24 O.C. VERT. —=
ALT. HOOKS
I I —III-_ z v_ w
� a� 0
.11 I —III : le..d
#4 0 10" O.C. HORZ. _— ` '. f
I I I —I JLJ-
I I —I I IE C° 1110 o
—III—I I ° '• , :.:°
I I— za w
N Dm
-I
-
00 �-
UN -YIELDING SOIL —
- a
_—
' I I I 1
I (2)#4 CONT.
w
w
3" 6" 3" U)
1'-0»
01
e
a NOTE: FOR UNBLANCED BACKFILL
as
OF 2'-7" - 4'-0" USE
[4"[ 8" 4"
ALTERNATE FOOTING DESIGN
1'-4" ALTERNATE FOOTING
oil
EXT SHEARWALL @ SLAB
3/4"=1'-0"
EDGE NAILING
PLYWOOD SPLICE
PANEL EDGE NAILING PER
SHEARWALL SCHEDULE
7/16" O.S.B. SHEAR PANEL
PLATE NAILING PER
SHEARWALL SCHEDULE
2x10 BLOCKING @
PLYWOOD SPLICE
END TRUSS PER
MANUFACTURER
PLATE NAILING PER
SHEARWALL SCHEDULE
(MIN. 16d @ 6" O.C.)
FOR SHEARWALL TYPE 4
USE A35F CLIP @ 12" O.C.
TRUSS PARALLEL TO EXTERIOR WALL
3 /4"=1'-0"
TRU!
.
1'-0"
a a NOTE: FOR UNBLANCED BACKFILL
a. OF 2'-7" - 4'-0" USE
ALTERNATE FOOTING DESIGN
° e
a
4„ 8„ 4„
01
01
1'-4" ALTERNATE FOOTING
EXTERIOR SHEARWALL @ CRAWL SPACE
3/4"=1'-0"
PER PLAN
SAVE @ ROOF
3/4"=1'-0"
2x4 RIBBON SUPPLIED BY TRUSS MFR.
ao
(2) CS16 STRAP/
FILL ALL HOLES —
w/ NAILS
2x4 RIBBON SUPPLIED -
BY TRUSS MFR.
JOISTS HANGING FROM STEM WALL
SIMPSON H1 EA. END/ EA. TRUSS/
RAFTER
PLY. EDGE NAILING
2x BLOCK w/ 1 1/2"
REQUIRED w/ (2)16d T.N.
EA. TRUSS/ EA. END
EDGE NAILING
2x STUD @ 16" O.C.
PLY. PER SCHEDULE
(2)2x STUDS
@ HOLDOWN
TRUSS PER PLAN
BLOCKING ATTACHED
BY TRUSS MFR.
SHEATHING FILLER PIECE
(2)2x STUDS
@ HOLDOWN
STRAP HOLDOWN AT FLOOR
3/4"=1'-0"
DOUBLE PORTAL
FRAME
SINGLE PORTAL FRAME
el o e e o° o e la e
e1 e e e e e e ,Iee 3"x11 1/4" MIN. HDR.
el e ° ° , ° ° °lee (BUILT-UP, SOLID SAWN,
el , e e ° e ° e le ° LGL, ETC.)
FASTEN T.PL. TO HDR. W/ 2 ROWS OF
16D SINKERS 03" o.c. (TYP.)
MSTC28 STRAP OPPOSITE SHEATHING
AS SHOWN (SEE SECTION A -A) (TYP.)
FASTEN SHEATHING TO HDR. W/ 8D COMMON
NAILS IN 3" GRID PATTERN AS SHOWN AND 3" ox.
IN ALL FRMNG. (STUDS & SILLS) TYP.
FOR FRAMES OVER 8", PANEL SPLICE (IF NEEDED)
SHALL OCCUR WITHIN 24" OF MID -HEIGHT. BLOCKING
IS REQUIRED. IF 2X_ BLOCKING IS USED THEN IT
MUST BE STITCH NAILED W/ 1 ROW OF 16D SINKERS
@ 3" o.c.
° STHD14 HOLD DOWN STRAP APPLIED
�• 1,16OVER SHEATHING INSTALLED IN CONCRETE
• •i• PER MANUFACTUREERS INSTRUCTION
I° °I°
l°e a —o o°le
sae —_a
• e e e e •- (2) 5/8" DIA. ANCHOR BOLT 7" MIN.
EEMMBEDDMENT 08" o.c.& 3"x3"x1 4" PLT. WASHER
1. 'I
e °.
J- a LJ° d 4
FRONT ELEVATION
MIN. LATERAL PANEL
1 /2"-1'-0"
END OF PLATE
NOTE:
SPLICE AND NAIL TOP PLATES AS SHOWN @ ALL
EXTERIOR WALLS, SHEAR WALLS, & AT EACH FLOOR
LEVEL AND AT ROOF.
ELEVATION
DBL. TOP PLATE SPLICE
3 /4"=1'-0"
SECTION
SUBFLOOR,
P PLATE
STUDS
PREMANUFACTURED FLOOR
TRUSS PER PLAN
8d @ 6" O.C.
(TYP) _,-v 2x BLOCKING
(4)12d BLOCKING TO J
PLATES @ EA. PANEL DBL. 2x TOP PLATE
ELEVATION
DBL. 2x
STA18
TRAP
TYPICAL
eie
POST FRAME
CONSTRUCITON
.i•
•i°
0101
I1
.I°i
el°I
I1
9101
oloro u—o
e,e,
Ii
vial
THD8 min.
0l°1
°i°
OWN STRAP
.2
I1
°I°I
o1°
2X_ FRAMING
PANEL EDGE NAILING PER
SHEARWALL SCHEDULE
2x10 RIM
PLYWOOD SPLICE
2x4 RIM
PANEL EDGE NAILING PER
SHEARWALL SCHEDULE
7/16" O.S.B. SHEAR PANEL
0 o e e a e e Ie
0 0 o s e e e la
°° o o e o e l•
0 0 o s e e e Is
SHEATHING FI
IF NEEDED
.—O e
— — -- —Teo
•i•
Q
•i• 16D-
SINKERS
°i° 2 ROWS @
°1° 3 O.C.
°i°
Ie1e
:l: 7/16" MIN.
THICKNESS
WOOD
1e1e
lele STRUCTURAL
PANEL
LJd ° e°LJ
4 '
A —A
7 16" MIN.
THI KNESS
WOOD
STRUCTURAL
PANEL
HDR.
STRAP
SECTION A —A
SIDE ELEVATION
PLATE NAILING PER
SHEARWALL SCHEDULE
FLOOR SHEATHING o/
MANUFACTURED TRUSSES
TRUSS PER PLAN
TRUSS PERPENDICULAR TO EXT. WALL
3/4"=1'-0"
8d @ 6" O.C.
SUB FLOOR
EXTERIOR
PLYWOOD
12d @ 4" O.C.
EDGE NAIL
�12d @ 4" O.C. ` 1 3/4"xFULL DEPTH" LSL
O.S.B. STIFFNER 7/16" PLY. SHEAR PANEL EDGE NAIL 2X RIM RIM OR BUILT-UP
TRUSS MFR.
w/ 2x4 EACH SIDE
w / 12d @ 4" O.C. 7/16" O.S.B./ PLYWOOD
NAIL PLY. w/ 8d @ 4" O.C. PER SCHEDULE
(TYP.)
0 NAILING DETAIL @ CANT. FLOOR TRUSS
3/4" T&G PLYWOOD SUBFLOOR TRUSS / DRAG 8d @ 4" OC
w/ EDGE NAILING TO BLOCKING STRUT DESIGN FOR PLYWOOD
PANEL BELOW 240#/FT LATERAL
I N LOAD
8d @ 6" O.C.
ALL EDGES
7/16" O.S.B.
STIFFNER w/
8d @ 4" Z\ak,4e
O.C.
ALL EDGES EDGE NAIL
2x4 BLOCKING (4 SIDES) w/ A35 @
12d @ 14" O.C. ALL EDGES 16" OC
EDGE NAIL PEPLYWOODi
R SCHED. SHEARWALL
2x4 STUDS @ 16" O.C. PER PLAN
(3)16d TO PLATES
TYP. EACH PANEL
SECTION PARALLEL
YM INT. SHEARWALL TO FLOOR ABV.
& -1'—n"
EDGE NAIL PLY. TO STUD
z
(1)2x STUDS
@ EACH HOLDOWN
�_
/-TRUSS PER PLAN
SIMPSON CS16 STRAP
FILL HOLES W/ 8d
NAILS AS SHOWN
`-BEAM PER PLAN
STRAP HOLDOWN AT HDR
3/4"=1'-0"
2021 CODE VERSION
SHEARWALL SCHEDULE:
SW-4
INDICATES SHEARWALL w/ SHEATHING ONE SIDE
1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/
8d @ 4"o.c. ALL EDGES & 12"o.c. FIELD.
2. BOLT SILL PLATE TO CONCRETE w/ 5/8 0 x 10" ANCHOR BOLTS @ 32"o.c.
3. NAIL BOTTOM PLATE TO FRAMING BELOW w/ 16d @ 3"o.c.
4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE PER DETAILS AS
PROVIDED.
SW-3
INDICATES SHEARWALL w/ SHEATHING ONE SIDE
1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/
8d @ 3"o.c. ALL EDGES & 12"o.c. FIELD.
2. a. BOLT (3)2x SILL PLATE TO CONCRETE w/ 5/8 0 x 12" ANCHOR BOLTS
@ 16"o.c. PER DETAIL D/S1
2. b. BOLT (2)2x SILL PLATE TO CONCRETE w/ 5/8 0 x 12" ANCHOR
BOLTS @ 16"o.c.
3. NAIL BOTTOM PLATE TO FRAMING BELOW w/ 16d @ 4"o.c.
4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE PER
DETAILS AS PROVIDED.
5. USE 3x OR (2)2x @ ALL FRAMING MEMBERS RECEIVING END NAILING
FROM ABUTTING PANELS.
sw-2
INDICATES SHEARWALL w/ SHEATHING ONE SIDE
1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/
8d @ 2"o.c. ALL EDGES & 12"o.c. FIELD.
2. BOLT (2)2x SILL PLATE TO CONCRETE w/ 5/8 0 x 12" ANCHOR BOLTS
@ 16"o.c.
3. FASTEN DOUBLE BOTTOM PLATE TO FRAMING BELOW w/ 2-LAYERS 16d @
3"o. c.
4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE w/ SIMPSON
LTP4 @ 10"o.c. PER DETAILS AS PROVIDED,
5. USE 3x OR (2)2x @ ALL FRAMING MEMBERS RECEIVING END NAILING
FROM ABUTTING PANELS.
TYPICAL ROOF SHEATHING:
7/16" O.S.B., INDEX 40/20, UNBLOCKED, w/ FACE GRAIN PERPENDICULAR
TO FRAMING BELOW.
NAIL AS FOLLOWS:
DIAPHRAGM BOUNDARY, OVER EXTERIOR
WALLS, SHEAR WALLS, & DRAG STRUTS: 8d @ 6"o.C.
ALL SUPPORTED EDGES: 8d @ 6"o.c.
FIELD: 8d @ 12"o.c.
TYPICAL FLOOR SHEATHING:
3/4" T&G O.S.B., INDEX 40/20, UNBLOCKED, LAID UP w/ FACE GRAIN
PERPENDICULAR TO FRAMING BELOW
STAGGER END JOINTS, GLUE & NAIL AS FOLLOWS:
DIAPHRAGM BOUNDARY, OVER EXTERIOR
WALLS, SHEAR WALLS, & DRAG STRUTS: 8d @ 6"o.c.
ALL SUPPORTED EDGES: 8d @ 6"o.c.
FIELD: 8d @ 10"o.c.
NOTES:
1. USE 3%3%1/4" PLATE WASHERS ON ALL ANCHOR BOLTS.
2. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE
EDGE OF THE BOTTOM PLATE ON
THE SIDE(S) w/SHEATHING PER NDS 2021 EDITION (SDPWS) 4.3.6.4.3
3. EXPANSION BOLTS MAY BE USED IN LIEU OF ANCHOR BOLTS
w/ SAME SPACING, DIAMETER & 4 1/2"min. EMBEDMENT.
4, ALL POWDER DRIVEN NAILS SHALL BE 2 3/4" LONG(min.) x
0.156 SHANK 0, w/ MINIMUM 1 1/4" PENETRATION.
5. USE 20d NAILS @ 3x FRAMING MEMBERS.
6. a. 8d NAILS SHALL BE .131 x 2 1/2" LONG
b. 10d NAILS SHALL BE .148 x 3" LONG
C. 16d NAILS SHALL BE .162 x 3 1/2" LONG
d. 20d NAILS SHALL BE .192 x 4" LONG
U
Cn
z
CO
r
CO
M
N
_00
0)
� 0
�//'��
VNJ
j
N J
LL
c
... �
W
C�
w
LL @
Z
4
N
of rn
Zr
.r
M w
m
Z
�
-0
NW
00 . .
W
C�
� j �C0
N E
M
N
M
w
J
Q
N
c�
UJ
O
O
Z
z
J
U
ti
00
O
00
O
o
z
w
O
CV
�I
w
W
0
cn
U
Q
�
co
Q
OO
O
CD
r
oy�s�Gis 4'1'�ti�
`SIGNAL �
EXPIRES 2/2025
Project
FILE NUMBER
DRAWN BY
Date
6.15.2024
Sheet
S1
8d ® 4" O.C.
PLY. TO BLOCK
(2)2x6 BLOCK
(6) 12d BRACE
TO BLOCK
0 01
0 0
0
1
(2)A35 CLIPS
0
W)2x6 DIAGONAL "T" BRACE /
RIDGE AND 010'-0" O.C. MAX.
(VERIFY w/ TRUSS MFGR.) 2x6 CONT.
12d ® 6" O.C. 2x6 CONT.
TO TOP PLATE
TYP. GABLE TRUSS DETAIL
3/4"=1'-0"
2x TRUSSES ® 24" O.C.
2x OUTRIGGER (OPTIONAL)
EGDE NAILING
DBL. TOP CHORD
HORZ. WEB BRACING BY
TRUSS MFGR. PER T.P.I. SPECS.
NAIL TO ALL TRUSSES
12d ® 6" O.C.
(2)2x6 CONT. ® GABLEEND TRU
MID HEIGHT
STRUCTURAL TRUSS w/ 2x4
FLAT INLET STUDS ® 24" O.C.
(2)A35 CLIPS (ONE EA. SIDE)
12d ® 6" O.C. (TRUSS TO 2x6)
EDGE NAILING
7/16" O.S.B. OR
1/2" PLYWOOD
CONT. PLY
ROOF TO F
8d@6"o. c.
16d04"o. c.
A35 CLIPS
ROOF PLY.
EDGE NAILING
MONO TRUSSES
PER PLAN
TRUSS HANGER
2x10 LEDGER
PER PLAN
w/(7) 16d®16"c
EDGE NAILING
PLY PER PLAN
2xBLOCKING
2xSTUDS ® 16"o.c.
2x LEDGER
w/(3) 16d016"o.c.
® EA. 2x STUD
(TYP.)
O.C.
). C.
PLY.
JOIST
AN
_I P ® 16"o. c.
IS 0 16"o.c.
TRUSS TO WALL CONNECTION
(2) 2x TOP PLATE, U.N.O
2x CRIPPLE STUDS 0 16" O.C.
WHERE HEADER IS NOT TIGHT
TO PLATE
(2) 2x HEADER OR BEAM
SIZER PER PLAN
2 ROWS OF 16d NAILS 0 8" O.C.
ALTERNATE NAILING FORM EACH SIDE
7/16" OSB SPACER
R-10 RIGID INSULATION (PER ARCH)
BUILT-UP HEADER
HTT5
HOLDOWN ANCHOR
FILL ALL HOLES w/ NAILS
(2)2x STUDS
EDGE NAILING PLY.
TO EACH DOUBLE STUD
5 8" DIA. THREADED ROD
I SIMPSON EPDXY- TIE 22
ADHESIVE SYSTEM OR EQUIVALENT
PER MFGR. RECOMMENDATION
CONC. FOUNDATION
TYP. HOLDOWN TO EXISTING HOOTING
3/4"=1'-0"
TO BE USED IN CASE OF A MISPLACED HOLD-DOWN
2x BLKG W/ 16d
TOE NAILS 0 6" O.C.
2x F.J'S PER PLAN
LAPE 6" W/ (4) 16d
FACENAILS
20 CLEAT
EA. SIDEAz SIMPSON A35 TWO SIDES
PT 40 POST
z PT 46 ® BM. SPLICE FOOTING AND REBAR
PER PLAN PER PLAN
a
=iTl=1 11-1 11-1 11-1 I I-1 I i="
CC POST PAD CONNECTION
3/4"=1'-0"
2x STUD, TYP.
2x4 STUD 2x4 STUD J
PLAN VIE W NAILING, TYP.
CORNER DETAIL
DOUBLE TOP PLATE
(4)16d
(2)16d TOES
Of 16d 0 12" O.C.
2x CRIPPLE
PER SCHED.
I
(2)16d
EA. STUD
II II II
SILL WHEN
APPLICABLE
BEARING OPENING
SEE SCHEDULE FOR
CRIPPLE & KING STUD
INFORMATION
�y�Dje>•��I
(1) 2x 8'-0" MAX
2 2x OVER 8'-0"
(2)16d TOENAIL
TOP & BOTTOM
WALL OPENING FRAMING SCHEDULE (UNO ON PLAN)
WIDTH OF OPENING
CRIPPLES
KINGS
COMMENTS
SILL
0 — 4'-0" MAX.
1
1
(4)16d EA. KING STUD TO HDR.
4'-1"— 5'-6" MAX.
2
1
(4)16d EA. KING STUD TO HDR.
5'-7" — 8-0" MAX.
2
2
(4)16d EA. KING STUD TO HDR.
& (1)LTP4 HDR TO EA. KING STUD
8'-1" & OVER
SEE PLANS
SEE PLANS
SEE PLANS
2021 CODE VERSION
I n *% 4 C J T^ r- K I A I I _rY P.
INTERIOR NON —BEARING OPENING
(NOT AT GARAGE TO HOUSE MAN DOOR)
NOTES:
1. ALL HEADERS PER PLAN
2. PROVIDE (2)2x6 HDR. ®BEARING
OPENINGS & BELOW STRUCTURAL
GIRDER END TRUSSES
3. SEE PLANS FOR INFORMATION NOT NOTES
WALL OPENING DETAIL
z
M
CON
_
0)
� 0
N Q
W
cu
w
LL V
z
Y
N
of rn
.r
co Lu
m
Z
�
a
00
W
C14
L j �C>3
N E
M
W
N
M
� W
7D
ti
00
O
00
m
o
W
Z
CV
Zw
OV
w
u)
U
Q
�
v,
M�
W
O
CD
EXPIRES 2/2025 I
Project
FILE NUMBER
DRAWN BY
Date
6.15.2024
Sheet
S2
(TYPICAL)
E
GENERAL STRUCTURAL NOTES
(The following applies unless specifically indicated otherwise on the plans.)
ox
w 1. ALL MATERIALS & WORKMANSHIP, DESIGN, & CONSTRUCTION SHALL CONFIRM TO THE REQUIREMENTS OF THE DRAWING
SPECIFICATIONS, THE INTERNATIONAL BUILDING CODE, 2021 EDITION.
2. DESIGN CRITERIA
ROOF LIVE LOAD (SNOW) 25 psf
PHOTOVOLTAIC PANEL SYSTEM 4 psf & 175 lb INVERTER LOAD ON 4 SQFT EVERY 1000 SQFT
SPRINKLERS 1.5 psf (IF APPLICABLE)
FLOOR LIVE LOAD (RESIDENTIAL) 40 psf
FLOOR LIVE LOAD (DECK) 60 psf (1.5x AREA SERVED)
HANDRAILS & GUARDS RAIL LINE LOAD: 50 psf RAIL CONCENTRATE LOAD: 200#
STAIR & CORRIDOR LIVE LOAD 100 psf
MECHANICAL UNITS WEIGHTS AS FURNISHED BY MFG.
WIND 100mph (BASIC WIND SPEED) EXPOSURE 'B' (RISK CATEGORY II) Kzt = 1.2
s 1
EARTHQUAKE S =1.60 S =.57 (CLASS 'D') LIGHT FRAMED SHEAR WALL R=6.5
ALLOWABLE SOIL PRESSURE 2,000 psf. (NATURAL SOILS or COMPACTED)
SEE PLANS & COMPUTATIONS FOR ADDITIONAL LOADING CRITERIA PER I.B.C. SECTION 1605-1609.
3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION w/ ARCHITECTURAL DRAWINGS FOR BIDDING CONSTRUCTION. CONTRACTOR
SHALL VERIFY DIMENSIONS & CONDITIONS FOR COMPATIBILITY & SHALL NOTIFY THE ARCHITECT & STRUCTURAL ENGINEER, OF ANY
DISCREPANCIES PRIOR TO CONSTRUCTION TO ALLOW ARCHITECT & ENGINEER TO COMPLETE PROPER REVISIONS TO THE WORK.
4. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE
INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED & IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION
DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING
DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 psf.
CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, & CONDITIONS PRIOR TO COMMENCING ANY WORK, ALL
DIMENSIONS OF EXISTING (e) CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY & MUST BE FIELD
VERIFIED.
5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING & SHORING FOR THE STRUCTURE & STRUCTURAL COMPONENTS UNTIL ALL FINAL
CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED SAFETY PRECAUTIONS & THE METHODS, TECHNIQUES, SEQUENCES &
PROCEDURES REQUIRED TO PERFORM HIS WORK.
7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT & THE STRUCTURAL ENGINEER FOR APPROVAL
PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT.
8. DRAWINGS INDICATE GENERAL & TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE
OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW & APPROVAL
BY THE ARCHITECT & STRUCTURAL ENGINEER.
9. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED, SHALL BE SUPERVISED BY THE
SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE & ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY
THE SUPPLIER.
10. SHOP DRAWINGS FOR STRUCTURAL STEEL, GLUED LAMINATED MEMBERS, OPEN WEB WOOD TRUSSES, & PLYWOOD WEB JOISTS SHALL
BE SUBMITTED TO THE ARCHITECT & STRUCTURAL ENGINEER FOR REVIEW TWO WEEKS PRIOR TO FABRICATION OF THESE ITEMS.
11. SHOP DRAWINGS REVIEW: DIMENSIONS & QUANTITIES ARE NOT REVIEWED BY THE ENGINEER OF RECORD, & THEREFORE MUST BE
VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL REVIEW & STAMP DRAWINGS PRIOR TO REVIEW BY
ENGINEER OF RECORD. SUBMISSIONS SHALL INCLUDE A REPRODUCIBLE & ONE COPY; REPRODUCIBLE WILL BE
MARKED & RETURNED.
SHOP DRAWINGS SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SHOP DRAWING
SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN
CONCEPT, THAT HE DEMONSTRATES HIS UNDERSTANDING BY INDICATING WHICH MATERIAL HE INTENDS TO FURNISH & INSTALL & BY
DETAILING THE FABRICATION & INSTALLATION METHODS HE INTENDS TO USE. IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN
SHOP DRAWING SUBMITTALS & THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS
ARE PROCESSED BY THE ENGINEER, THE DESIGN DRAWINGS & SPECIFICATIONS SHALL CONTROL & SHALL BE FOLLOWED.
GEOTECHNICAL
12. FOUNDATION NOTES:
SUB -GRADE PREPARATION INCLUDING DRAINAGE, EXCAVATION, COMPACTION, & FILLING REQUIREMENTS, SHALL CONFORM
STRICTLY WITH RECOMMENDATIONS GIVEN IN THE SOILS REPORT JN23021 BY GEOTECH CONSULTANTS, INC DATED ON JAN 30, 2023.
FOOTINGS SHALL BEAR ON SOLID UNDISTURBED EARTH (CONTROLLED, COMPACTED STRUCTURAL FILL or BOTH) AT LEAST 18" BELOW
LOWEST ADJACENT FINISHED GRADE. FOOTING DEPTHS/ELEVATIONS SHOWN ON PLANS (or IN DETAILS) ARE MINIMUM & FOR GUIDANCE
ONLY; THE ACTUAL ELEVATIONS OF FOOTINGS MUST BE ESTABLISHED BY THE CONTRACTOR IN THE FIELD WORKING WITH THE TESTING
LAB & SOILS ENGINEER. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING GRANULAR FILL & PROVIDE FOR SUBSURFACE
DRAINAGE.
STRUCTURAL FILL:
AS APPLICABLE PER SITE CONDITIONS OR AS DIRECTED BY THE SOILS ENGINEER. FOLLOW ALL RECOMMENDATIONS &
SPECIFICATIONS AS GIVEN PER THE SOILS REPORT.
CONCRETE
13. CONCRETE SHALL ATTAIN A 28 DAY STRENGTH OF f c= 2,500 psi & MIX SHALL CONTAIN NOT LESS THAN 5 1/2 SACKS OF CEMENT
PER CUBIC YARD & NO MORE THAN 6 GALLONS OF WATER PER SACK OF CEMENT.
ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO I.B.C. THE AMOUNT
SHALL BE 47o + 1% BY VOLUME. fc = 3,000 psi.
14. REINFORCING STEEL SHALL CONFORM TO ASTM A615, (INCLUDING SUPPLEMENT S1) GRADE 60, fy = 60,000 psi. EXCEPTION:
COLUMN TIES, BEAM STIRRUPS, BARS TO BE FIELD BENT, BARS TO BE WELDED & ANY OTHER BARS SPECIFICALLY SO NOTED ON THE
DRAWINGS SHALL BE GRADE 40, fy = 40,000 psi REINFORCING COMPLYING WITH ASTM A706 (S1) MAY BE WELDED ONLY IF MATERIAL
PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN A.W.S. D1.4 ARE SUBMITTED. NO REINFORCING
SHALL BE WET -SET UNLESS SPECIFICALLY SO DETAILED.
WELDED WIRE MESH SHALL CONFORM TO ASTM A-185.
15. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS & BENDS) IN ACCORDANCE WITH ACI 318-19. LAP ALL CONTINUOUS
REINFORCEMENT 58 BAR DIAMETERS (2'-6" min.). PROVIDE CORNER BARS AT ALL WALL INTERSECTIONS. LAP CORNER BARS 30 BAR
DIAMETERS (2'-6" min.). LAP ADJACENT MATS OF WELDED WIRE FABRIC TWO SQUARES (min. OF 12") AT SIDES & ENDS.
NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY
THE STRUCTURAL ENGINEER.
16. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS:
FOOTINGS & OTHER UNFORMED SURFACES, EARTH FACE 3"
FORMED SURFACES EXPOSED TO EARTH (i.e. WALLS BELOW GROUND) OR WEATHER
#6 BARS OR LARGER 2"
#5 BARS OR SMALLER 1 1/2"
COLUMN TIES OR SPIRAL & BEAM STIRRUPS 1 1/2"
SLABS & WALLS (INTERIOR FACE) 3/4-
CAST-IN-PLACE CONCRETE:
SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS & DIMENSIONS OF DOOR & WINDOW OPENINGS IN ALL CONCRETE WALLS.
SEE MECHANICAL DRAWINGS FOR SIZE & LOCATION OF MISCELLANEOUS MECHANICAL OPENINGS THROUGH CONCRETE WALLS, SEE
ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, & OTHER FINISH DETAILS
AT ALL EXPOSED CONCRETE SURFACES, BOTH CAST -IN -PLACE & PRECAST.
17. NON -SHRINK GROUT (3,000psi MINIMUM STRENGTH) SHALL BE FURNISHED BY AN APPROVED MANUFACTURER & SHALL BE MIXED &
PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURE'S PUBLISHED RECOMMENDATIONS.
CTl�_ �_I
18. STRUCTURAL STEEL DESIGN, FABRICATION, & ERECTION SHALL BE BASED ON ON THE A.I.S.C. "SPECIFICATION FOR THE DESIGN,
FABRICATION, & ERECTION OF STRUCTURAL STEEL BUILDINGS", LATEST EDITION, PLUS ALL REFERENCES CODES.
19. STRUCTURAL WIDE FLANGE SHAPES TO CONFORM TO ASTM A992, Fy = 50 ks
OTHER STRUCTURAL STEEL INCLUDING PLATES SHALL CONFORM TO ASTM A36, Fy = 36 ksi
STEEL PIPE SHALL CONFORM TO ASTM A-53, TYPE E, OR S, GRADE B, Fy = 35 ksi
STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, Fy = 46 ksm
BOLTS SHALL CONFORM TO ASTM A307 (CONNECTION BOLTS A325-N)
EXPANSION SHALL BE "PARABOLT" or APPROVED EQUAL INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURES'S PUBLISHED
RECOMMENDATION.
EXPANSION BOLTS SHALL ALSO BE SIMPSON STRONG BOLT INSTALLED PER ICC-ESR REQUIREMENTS OR EQUAL.
20, ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.C. & A.W.S. STANDARDS & SHALL BE PERFORMED BY W.A.B.O. CERTIFIED
WELDERS USING E70XX ELECTRODES,
ONLY PRE -QUALIFIED WELDS (AS DEFINED BY A.W.S.) SHALL BE USED,
WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E70XX ELETRODES & PER ASTM A706. WELDING
WITHIN 4" OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS
OF WELDED BARS.
STEEL FABRICATION
GENERAL:
ALL WELDING IS REQUIRED TO BE DONE BY A WABO CERTIFIED WELDER & HAVE SPECIAL INSPECTIONS BY WABO CERTIFIED
INSPECTION AGENCY, OR BE DONE IN A WABO CERTIFIED FABRICATION SHOP.
HAVE EITHER THE SPECIAL INSPECTION REPORT OR WABO FABRICATION SHOP CERTIFICATION AVAILABLE ON SITE FOR THE
BUILDING INSPECTOR.
21. WELDING:
1) WELDING SHALL CONFIRM TO AWS D1.1 & VISUALLY CONFIRM TO AWS SECTION 6 & TABLE 6.1. FABRICATION/ERECTION
INSPECTIONS BY THE CONTRACTOR PER AWS D1.1 SECTION 6, SHALL BE BY ASSOCIATE/CERTIFIED INSPECTORS (AWI/CWI) PER
AWS QC1 OR AWS B5.1. SPECIAL INSPECTIONS (VERIFICATION INSPECTIONS SHALL BE BY A CERTIFIED WELDING INSPECTOR (WI)
OR SENIOR WELDING INSPECTOR (SWI) PER AWS B5.1
2) WELDERS SHALL BE QUALIFIED FOR THE SPECIFIC PRE -QUALIFIED JOINTS REQUIRED BY THE DESIGN & CERTIFIED IN
ACCORDANCE WITH WABO REQUIREMENTS.
3) WELDING SHALL BE DONE IN ACCORDANCE WITH APPROPRIATE WELD PROCEDURE SPECIFICATIONS (WPS's). WELDERS SHALL BE
FAMILIAR WITH THE APPLICABLE WPS's.
4) WELDING SHALL BE DONE WITH AWS PRE -QUALIFIED WELDING PROCESSES UNLESS OTHERWISE APPROVED.
5) WELDER QUALIFICATIONS & WPS's SHALL BE MAINTAINED AT THE SITE OF THE WORK & SHALL BE READILY AVAILABLE FOR
INSPECTION UPON REQUEST, BOTH IN THE SHOP & IN THE FIELD.
6) USE E70 OR E71 T, 70ksi STRENGTH ELECTRODES APPROPRIATE FOR THE PROCESS SELECTED.
22. FABRICATION:
1) CONFORM TO AISC 303, SECTION 8 & AISC 360 SECTION M2 & M5.
2) STRUCTURAL WELDING & QUALIFICATIONS SHALL CONFORM TO THE AWS D1.1
23. VERIFICATION INSPECTION:
1) STRUCTURAL WELDING INSPECTIONS & QUALIFICATIONS SHALL CONFIRM TO THE AWS D1.1. SEE WELDING NOTES & SPECIAL
INSPECTIONS FOR STRUCTURAL STEEL.
2) SPECIAL INSPECTOR SHALL REVIEW THE PROCEDURES FOR COMPLETENESS & ADEQUACY RELATIVE TO THE CODE & THE WORK.
FURTHER SHOP SPECIAL INSPECTIONS MAY BE WAIVED IF THE FABRICATOR IS "AISC CERTIFIED" OR OTHERWISE "APPROVED" BY
THE AUTHORITY HAVING JURISDICTION PER IBC SECTION 1704.2.2 SEE SPECIAL INSPECTIONS FOR STRUCTURAL STEEL.
24. ERECTION:
1) CONFIRM TO AISC 303, SECTION 7 "ERECTION", SECTION 8 "QUALITY ASSURANCE." & AISC 360, SECTION M4.
2) THE ERECTOR SHALL MAINTAIN DETAILED FABRICATION & ERECTION QUALITY CONTROL PROCEDURES THAT ENSURE THAT THE WORK
IS PERFORMED IN ACCORDANCE WITH AISC 360 SECTION M, AISC 303, & THE CONTRACT DOCUMENTS.
3) STEEL WORK SHALL BE CARRIED UP TRUE & PLUMB WITHIN THE LIMITS DEFINED IN AISC 303, SECTION 7.13.
4) STRUCTURAL WELDING TO CONFORM TO THE AWS D1.1 & APPLICABLE WELDING NOTES ABOVE.
5) SPECIAL INSPECTOR SHALL INSPECT THE STEEL FRAMING TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN ON THE CONTRACT
DOCUMENTS INCLUDING MEMBER SIZE, LOCATION, BRACING & THE APPLICATION OF PROPER JOINT DETAILS AT EACH
CONNECTION.
25. BRACING & SAFETY PROTECTION:
THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING & SAFETY PROTECTION REQUIRED BY AISC 360 SECTION M4.2 & AISC 303
SECTION 7010 & 7.11.
26. PROTECTIVE COATING REQUIREMENTS:
1) SHOP PAINTING: CONFORM TO AISC 360 SECTION M3 & AISC 303 SECTION 6.5 UNLESS A MULTI -COAT SYSTEM IS REQUIRED
PER THE PROJECT SPECIFICATIONS.
2) INTERIOR STEEL:
a. UNLESS NOTED OTHERWISE, DO NOT PAINT STEEL SURFACES TO BE,
1. WELDED; IF AREA REQUIRES PAINTING, DO NOT PAINT UNTIL AFTER WELD INSPECTION & NON-DESTRUCTIVE
TESTING REQUIREMENTS, IF ANY, ARE SATISFIED.
b. INTERIOR STEEL, EXPOSED TO VIEW, SHALL BE PAINTED WITH ONE COAT OF SHOP PRIMER UNLESS OTHERWISE INDICATED
IN THE PROJECT SPECIFICATIONS. FIELD TOUCH-UPS TO MATCH THE FINISH COAT OR AS OTHERWISE INDICATED IN THE
PROJECT SPECIFICATIONS.
AlTraffaffirs
27. FRAMING LUMBER SHALL BE KILN DRIED OR MC-15 (MC-192), & GRADED & MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD
GRADING RULES FOR WEST COAST LUMBER NO. 16 (172), LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS:
JOISTS (2x MEMBERS) HEM -FIR #2
BEAMS & STRINGERS DOUGLAS FIR #1
POSTS & TIMBERS DOUGLAS FIR #1
STUDS, PLATES & MISC. LIGHT FRAMING DOUGLAS FIR or HIM -FIR STAND. GRADE
TOP & BOTTOM PLATES @ BEARING & SHEAR WALLS DOUGLAS FIR #2 or CONST. GRADE
BOLTED STUDS, LEDGERS & PLATES HEM -FIR #2 or CONST. GRADE 2
2x6 STUDS HEM -FIR #2 or HEM -FIR CONST. GRADE 2
28. GLUE -LAMINATED MEMBERS SHALL BEAR AN AITC IDENTIFICATION MARK & SHALL BE ACCOMPANIED BY AN AITC CERTIFICATION OF
CONFORMANCE.
ALL SIMPLE SPAN BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V4, Fb= 2,400 psi, Fv = 240 psi.
ALL CONT. & CANTILEVER BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V8, Fb = 2,400 psi, Fv = 240 psi.
29. LAMINATED VENEER LUMBER SHALL BE FABRICATED IN CONFORMANCE WITH ICC-ES ESR-1387. EACH MEMBER SHALL BEAR AN
IDENTIFICATION MARK.
ALL BEAMS SHALL BE WESTERN SPECIES, GRADE 1.8E, Fb = 2,600 psi, Fv = 285 psi.
30. LAMINATED STRAND LUMBER (TIMBERSTRAND LSL) SHALL BE FABRICATED IN CONFORMANCE WITH CODE EVALUATION ICC ES
ESR-1387. EACH MEMBER SHALL BEAR AN IDENTIFICATION MARK.
ALL BEAMS SHALL BE WESTERN SPECIES, GRADE 1.55E, Fb = 2,325 psi, Fv = 310 psi.
31. PARALLEL STRAND LUMBER SHALL BE FABRICATED IN CONFORMANCE WITH ICC-ES ESR-1387. EACH MEMBER SHALL BEAR AN
IDENTIFICATION MARK.
ALL BEAMS SHALL BE DOUGLAS FIR, GRADE 2.OE, Fb = 2,900 psi, Fv = 290 psi
32. [DEFERRED SUBMITTAL:] PREFABRICATED OPEN WEB WOOD TRUSSES (or COMBINATION WOOD & METAL) SHALL BE DESIGNED BY THE
MANUFACTURER FOR THE SPANS & CONDITIONS SHOWN ON THE PLANS & SHALL BE FURNISHED & INSTALLED IN CONFORMANCE WITH
THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. ALL NECESSARY BRACING, BRIDGING, BLOCKING, PRE -NOTCHED PLATES ETC.,
SHALL BE DETAILED & FURNISHED BY THE MANUFACTURER.
SUBMIT SHOP DRAWINGS & DESIGN CALCULATIONS (COMPLETE WITH STRESS DIAGRAMS) TO THE ARCHITECT & THE STRUCTURAL
ENGINEER FOR REVIEW TWO WEEKS PRIOR TO FABRICATION.
DESIGN SUBMITTALS SHALL BEAR THE STAMP OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON.
PERMANENT & TEMPORARY BRIDGING & BRACING SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS.
33. PLYWOOD SHEATHING SHALL BE GRADE C-D EXTERIOR GLUE or STRUCTURAL II, EXTERIOR GLUE ORIENTED STRAND BOARD OF
EQUIVALENT THICKNESS, EXPOSURE 1 RATING & PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD.
SEE PLANS FOR THICKNESS, PANEL IDENTIFICATION INDEX & NAILING REQUIREMENTS.
STRUCTURAL WOOD SHEATHING PANELS SHALL HAVE APA GRADE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION.
34. ALL WOOD PLATES & BLOCKING IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN A.W.P.A.
APPROVED PRESERVATIVE.
PROVIDE 2-LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LEDGERS, BLOCKING, ETC., & CONCRETE OR
MASONRY,
35. TIMBER CONNECTORS CALLED OUT BY LETTERS & NUMBERS SHALL BE BY SIMPSON COMPANY, AS SPECIFIED IN
THEIR CATALOG.
EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC APPROVAL FOR
EQUAL or GREATER
LOAD CAPACITIES. PROVIDE NUMBER & SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL
BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
WHERE CONNECTORS STRAPS CONNECT TWO MEMBERS, PLACE HALF OF THE NAILS or BOLTS IN EACH MEMBER.
ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS & NUTS OF
ALL BOLTS & LAG
SCREWS BEARING ON WOOD UNLESS NOTED OTHERWISE.
ALL NAILS SHALL BE COMMON.
ALL SHIMS SHALL BE SEASONED & DRIED & THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED.
ALL JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS.
ALL DOUBLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS.
ALL TRIPLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS.
TJI JOIST HANGERS PER MANUFACTURER TJI SHOP DRAWINGS (U.N.O.)
36. PROTECTION OF CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD ALL BOLTS, NAILS, JOIST HANGERS &
ANY OTHER
CONNECTORS SHALL BE HOT DIPPED GALVANIZED FASTENERS RECOMMENDED TO CONFORM WITH ASTM STANDARD A-153
& HOT DIPPED
GALVANIZED CONNECTORS SHOULD CONFORM TO ASTM A165, CLASS G-183. STAINLESS STEEL FASTENERS & CONNECTORS SHOULD BE
TYPE 304 OF 316 SIMPSON PRODUCT FINISHES CORRESPONDING TO THESE REQUIREMENTS ARE ZMAX 9158 (HOT DIPPED
GALVANIZED) & SST3000 (STAINLESS STEEL).
37. ALL WOOD FRAMING DETAILS - THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS.
A. MINIMUM NAILING REQUIREMENTS: UNLESS OTHERWISE NOTED, MINIMUM NAILING SHALL BE IN ACCORDANCE WITH TABLE
2304,10.1 OF THE INTERNATIONAL BUILDING CODE.
B. AT SAWN TIMBER JOIST AREAS: PROVIDE CROSS -BRIDGING @ 8'-0"o.c. max. SPACING & SOLID BLOCKING AT BEARING
POINTS, PROVIDE DOUBLE JOISTS UNDER ALL PARTITIONS. PROVIDE DOUBLE JOISTS EACH SIDE OF OPENINGS UNLESS DETAILED
OTHERWISE.
C. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITIONS THAT EXTEND MORE THAN HALF THE JOIST LENGTH & DOUBLE JOIST
HEADERS & DOUBLE JOISTS EACH SIDE OF ALL OPENINGS IN FLOORS & ROOFS UNLESS DETAILED OTHERWISE. COORDINATE SIZE
& LOCATION OF ALL OPENINGS WITH ARCHITECTURAL & MECHANICAL DRAWINGS.
D. PROVIDE TWO 2x10 HEADERS OVER & DOUBLE STUDS EACH SIDE OF ALL OPENINGS IN STUD BEARING WALLS NOT DETAILED
OTHERWISE,
E. PROVIDE SOLID BLOCKING FOR WOOD COLUMNS & MULTIPLE STUD POSTS THROUGH FLOORS TO SUPPORTS BELOW.
F. PROVIDE CONTINUOUS SOLID BLOCKING AT MID OF ALL STUDS OVER 10' IN HEIGHT.
G. TOENAIL JOISTS TO SUPPORTS WITH 2-16d NAILS. ATTACH ALL BEAMS AT THE ROOF EXCEEDING 8'-0" IN LENGTH TO
SUPPORTS WITH ST22 STRAP EACH END.
H. ATTACH TIMBER JOISTS TO FLUSH HEADERS AND BEAMS WITH "U" SERIES METAL JOIST HANGERS TO SUIT THE JOIST SIZE
I. WALL FRAMING ALL STUD WALL SHOWN & NOT OTHERWISE NOTED SHALL BE 2x4 STUDS @ 16"o.c. AT INTERIOR WALLS & 2x6
STUDS @ 16" o.c. AT EXTERIOR WALLS.
J. NOTATIONS ON DRAWINGS RELATING TO FRAMING CLIPS, JOIST HANGERS, & OTHER CONNECTING DEVICES REFER TO CATALOG
NUMBERS OF CONNECTORS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY OR EQUIVALENT DEVICES BY OTHER
MANUFACTURES MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL LOAD CAPACITIES.
K. INDIVIDUAL MEMBERS OF BUILT-UP POSTS & BEAMS SHALL EACH BE ATTACHED WITH 16d NAILS @ 6"o.c. STAGGERED.
L. ALL WOOD STUDS WALLS SHALL HAVE LOWER WOOD PLATE ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS @ 6" o.c.
STAGGERED UNLESS SHOWN OTHERWISE.
M. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO MINIMUM STANDARDS OF THE INTERNATIONAL
BUILDING CODE.
N. PLYWOOD ROOF SHEATHING & FLOOR SHEATHING UNLESS OTHERWISE NOTED ON PLANS SHALL BE LAID UP WITH FACE GRAIN
PERPENDICULAR TO SUPPORTS & NAILED WITH 8d NAILS @ 6" o.c. TO FRAMED PANEL EDGES & OVER STUD WALLS SHOWN ON
PLANS & @ 12"o.c. (10"o.c. AT FLOORS TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED EDGE CLIPS @ 16"o.c. AT
UNBLOCKED ROOF SHEATHING EDGES.
PROVIDE SOLD BLOCKING AT LINES OF SUPPORT AT FLOORS.
TOENAIL BLOCKING TO SUPPORTS WITH 16d NAILS @ 12"o.c. UNLESS OTHERWISE NOTED IN THE SHEAR WALL SCHEDULE.
0. PLYWOOD WALL SHEATHING SHALL HAVE SOLID BLOCKING AT ALL EDGES.
P. ALL WOOD STUD WALLS SHALL HAVE LOWER WOOD PLATE ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 6"o.c.
STAGGERED or BOLTED TO CONCRETE WITH 5/8" DIA. ANCHOR BOLTS @ 4'-0"o.c. UNLESS SHOWN OTHERWISE.
Q. PLYWOOD NAILING: (USE UNLESS GREATER NAILING IS DETAILED OR SPECIFIED)
8d @ 6"o.c. AT SHEET EDGES
8d @ 12"o.c. AT INTERMEDIATE BEARING POINTS
R. 1.
PROVIDE
ABU POST BASE @ ISOLATED POSTS
TO CONCRETE
CONNECTION
2.
PROVIDE
(2)A35 CLIPS @ TOP & BOTTOM OF
ALL POST TO
OTHER FRAMING MEMBERS
3.
PROVIDE
AC or ACE POST CAP @ ISOLATED POSTS
TO BEAM CONNECTIONS
4.
PROVIDE
MIN. (2)A35 CLIPS @ POST TO BEAM
CONNECTION
(U.N.O.)
5.
PROVIDE
(2)CS16 x 30" AT ALL CUT DOUBLE
TOP PLATES,
TYPICAL,
S. PROVIDE (2)CS16 x 36" AT ALL CUT DOUBLE TOP PLATE, TYP.
T. ANCHORAGE:
EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING
BAR) SPECIFIED
ON THE DRAWINGS SHALL BE
INSTALLED USING "SET-XP" HIGH STRENGTH EPDXY AS MANUFACTURED
BY
THE SIMPSON STRONG -TIE COMPANY. INSTALL
IN
STRICT ACCORDANCE WITH ICC-ES REPORT NO. ESR-2508.
MINIMUM BASE
MATERIAL TEMPERATURE IS 507. RODS SHALL
BE
ASTM A-36 UNLESS OTHERWISE NOTED. PERIODIC SPECIAL
INSPECTION OF
INSTALLATION IS REQUIRED TO VERIFY ANCHOR
OR
EMBEDDED BAR TYPE & DIMENSIONS, LOCATION, ADHESIVE
IDENTIFICATION & EXPIRATION, HOLE DIMENSIONS, HOLE CLEANING
PROCEDURE, ANCHOR EMBEDMENT & ADHERENCE TO THE INSTALLATION INSTRUCTIONS. CONTINUOUS SPECIAL INSPECTION
IS
REQUIRED FOR HORIZONTAL & OVERHEAD INSTALLATIONS.
EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING
"AT-XP" AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH IAMPO REPORT NO.
ER-0281. MINIMUM BASE MATERIAL TEMPERATURE IS 14'F. RODS SHALL BE ASTM A-36 UNLESS OTHERWISE NOTED. PERIODIC
SPECIAL INSPECTION OF INSTALLATION IS REQUIRED TO VERIFY ANCHOR OR EMBEDDED BAR TYPE & DIMENSIONS, LOCATIONS,
ADHESIVE IDENTIFICATIONS & EXPIRATION, HOLE DIMENSIONS, HOLE CLEANING PROCEDURE, ANCHOR EMBEDMENT, & ADHERENCE
TO THE INSTALLATION INSTRUCTIONS. CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR HORIZONTAL & OVERHEAD
INSTALLATIONS.
2021 IBC CODE VERSION
d
Z
M~
co
_CD
rn
N
1
2
O
04
0
J
N
Q
W
W
ALL@
Z
Y04
0
rn
N
M
W
0
V
N
00
W
N
N
LO
N
CU
E
M
W
L.L
0
O
Z
CU
V
U)
00
-
0
00
L_
0
Q
O
O
Z
W
J
CV
W
W
U
cn
U
Q
00
0
co
EXPIRES 2 2025
Project
Project No.
Drawn By
Date
6.15.2024
Sheet
S3
12%18" PLOT = 112 SCALE
2021 IRC WHOLE HOUSE VENTILATION INFORMATION
WASHINGTON STATE AMENDED
WHOLE HOUSE VENTILATION SYSTEM
IRC M1505.4 WHOLE HOUSE VENTING USING EXHAUST FANS
WHOLE HOUSE VENTILATION RATE: 65 CFM. FROM TABLE M1505.4.3(1) CONTINUOUS OPERATION
SEE CHART BELOW FOR ADJUSTED CFM
2018 TABLE M1505.4.3(2) WHOLE HOUSE VENTILATION QUALITY ADJUSTMENT (Cq)
SYSTEM TYPE
DISTRIBUTED
NOT DISTRIBUTED
MIN. ADJUSTED FAN SIZE (CFM)
BALANCED
1.0
1.25
NOT BALANCED
1 1.25
1.5
97.5
KEY REQUIREMENTS OF EACH SYSTEM:
A CLEARLY VISIBLE LABEL SHALL BE AFFIXED TO THE CONTROLS THAT READS
"WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)."
IRC M1505.4.1.1: WHOLE HOUSE VENTILATION SUPPLY AND EXHAUST FANS SHALL HAVE A MINIMUM EFFICACY AS PRESCRIBED IN THE WA STATE ENERGY CODE
WHOLE HOUSE FANS SHALL BE RATED AT NO LESS THAN THE MINIMUM AIRFLOW RATE REQUIRED BY SECTION M1505.4.3.1
VENTILATION FANS SHALL BE RATED FOR SOUND AT A MAXIMUM OF 1.0 SONE
IRC M1505.4.1.2 EXHAUST FANS SHALL BE DUCTED OUTSIDE DIRECTLY
EXHAUST FANS SHALL TO LIMIT THE PRESSURE DIFFERENCE TO THE OUTSIDE AND EQUIPPED WITH BACK DRAFT DAMPERS PER WA STATE ENERGY CODE
EXHAUST FANS SHALL BE RATED AND TESTED IN ACCORDANCE WITH THE AIRFLOW AND SOUND RATING PROCEDURES OF THE HOME VENTILATING INSTITUTE
IRC M1505.4.1.3: SUPPLY FANS SHALL SUPPLY OUTDOOR AIR FROM INTAKE OPENINGS IN ACCORDANCE WITH IMC SECTIONS 401.4 AND 401.5
IRC M1505.4.2: WHOLE HOUSE VENTILATION SYSTEM SHALL BE CONTROLLED WITH SWITCHES, TIMERS OR OTHER MEANS THAT PROVIDE AUTOMATIC OPERATION OF
THE VENTILATION SYSTEM WITH READY ACCESS BY THE OCCUPANT. CONTROLS SHALL PROVIDED TO OVERRIDE SYSTEM IN TIMES OF POOR AIR QUALITY. CONTROLS
SHALL INCLUDE PERMANENT TEXT OR A SYMBOL INDICATING THEIR FUNCTION. SUGGESTED "LEAVE ON UNLESS OUTDOOR AIR QUALITY IS VERY POOR"
MANUAL CONTROLS SHALL BE READILY ACCESSIBLE. WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CONFIGURED TO OPERATE CONTINUOUSLY EXCEPT
WHERE INTERMITTENT OFF CONTROLS AND SIZING ARE PROVIDED PER SECTION M1505.4.3.2
NOTE: THE ABOVE NOTES ARE EXCERPTS FROM THE CODE. FOR COMPLETE DETAILS, YOU MUST REFER TO THE CODE
SECTIONS FOR TOTAL COMPLIANCE.
THE REQUIRED WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM CERTIFICATE TO BE COMPLETED BY A MECHANICAL CONTRACTOR,
TEST AND BALANCE CONTRACTOR, OR OTHER APPROVED PARTY, LISTING THE TYPE OF SYSTEM USED AND THE DELIVERED AIRFLOW
AS INSTALLED AND POSTED IN AN APPROVED LOCATION PER M1505.4.1.7
WHOLE HOUSE VENTILATION SIZING INFORMATION
TABLE M1505.4.3(1)
WHOLE HOUSE MECHANICAL VENTILATION
(FT
BEDROOMS0)
0-1
2
3
4
5 OR MORE
<500
30
30
35
45
50
500-1000
30
35
40
50
55
1001-1500
30
40
45
55
60
1501-2000
35
45
50
60
65
2001-2500
40
50
55
65
70
2501-3000
45
55
60
70
75
3001-3500
50
60
65
75
80
3501-4000
55
65
70
80
85
4001-4500
60
70
75
85
90
4501-5000
65
75
80
90
95
TABLE M1505.4.4.1
MINIMUM LOCAL EXHAUST RATES
AREA TO BE
VENTILATED
VENTILATION RATES
INTERMITTENT
CONTINUOUS
OPEN
KITCHENS
IN ACCORDANCE WITH
SECTION M1505.4.4.3
NOT PERMITTED
ENCLOSED
KITCHENS
IN ACCORDANCE WITH
SECTION M1505.4.4.3
5 ACH BASED ON
KITCHEN VOLUME
BATHROOMS -
TOILET ROOMS
50 CFM
20 CFM
REFERENCE SECTION M1505.4.4.2 FOR ALL EXHAUST
FAN REQUIREMENTS AND DUCT SYSTEM
MECHANICAL SYSTEMS
Electrical
60. Electrical Connections. Equipment electrical connection shall be
regulated in accordance with the adopted state electrical code.
Exceptions:
1. Means of disconnect. Independent means of disconnect for the electrical
supply to each piece of equipment shall be provided in sight of the
equipment served when the supply voltage exceeds 50 volts.
2. Service Receptacle. A 120-volt service receptacle shall be located
within 25 feet of, and on the some level as, the equipment.
3. Illumination. Permanent switch controlled lighting shall be installed
for maintenance of equipment. The lighting shall provide sufficient
illumination to safely approach the equipment and perform maintenance.
Control of the lighting shall be provided at the access entrance.
Equipment
61. Mechanical Equipment.. Equipment shall be approved by the building
official for safe use or comply with applicable nationally recognized
standards as evidenced by the listing and label of an approved agency.
Listed appliances. The installer shall leave the manufacturer's
installation and operating instructions attached to the appliance.
Clearances of listed appliances from combustible materials shall be as
specified in the listing or on the rating plate.
62. Water Heaters. Fuel burning water heaters shall not be installed in
bathrooms or in a closet with access only through a bedroom or bathroom.
Exceptions:
1. Water heaters installed having direct vent systems.
2. Water heaters installed in a closet that has a weather-stripped solid
door with an approved door closing device, and designed exclusively for
the water heater and where all air for combustion and ventilation is
supplied from the outdoors.
3. Water heaters of the automatic storage type installed as a replacement
in a bathroom, when specifically approved, properly vented and supplied
with adequate combustion air.
Heating system
Water heaters shall be installed in accordance with the manufacturers installation
instructions and the requirements of this code. Water heaters shall be anchored against
movement and overturning in accordance with M1307.2. Gas -fired water heaters shall
conform to the requirements in Chapter 24. with UL 174. Oiled -fired water heaters
shall comply with UL 732
Prohibited locations: Fuel -fired water heaters shall not be installed in a room used as a
storage closet. Water heaters located in a bedroom or bathroom shall be installed in a
sealed enclosure so that combustion air will not be taken from the living space. Installation
of direct -vent water heaters within an enclosure is not required. M2005.2.
64. Listing Required. All furnaces shall be listed and labeled by an
approved agency and installed to listed specifications.
Location
65. Installation Per Listing. Equipment shall be located as required in
Section M1307 & M1308, IRC, specific requirements elsewhere in the IRC and the
conditions of the equipment's approval.
66, Prohibited Location. Fuel -burning equipment shall not be installed in
a closet, bathroom or a room readily usable as a bedroom, or in a room,
compartment or alcove opening directly into any of these, except direct
vent equipment, electric heat furnaces and other conditions noted in
In areas subject to flooding, equipment which would be damaged or create
hazardous conditions if subjected to inundation shall not be installed at
or below grade unless suitably protected by elevation or other approved
means.
67. Liquefied petroleum gas burning appliances shall not be installed in a
pit, an underfloor space, below grade or similar location where vapors or
fuel might unsafely collect unless an approved method for the safe
collection, removal and containment or disposal of the vapors or fuel is
provided.
68, Clearances. Furnaces within compartments or alcoves shall be accessed
by an opening or door and an unobstructed passageway measuring not less
24" wide and large enough to allow removal of the largest appliance in the
space, provided there is a space 30" deep & the height of the appliance
but not less than 30" at the front or service side with the door open.
Section M1305.1.1, IRC.
70. Support. Appliances designed to be in a fixed position shall be
securely fastened in place. Supports for appliances shall be designed and
constructed to sustain vertical and horizontal loads within the stress
limitations in the building code. Section M1307.2, IRC.
71. Mechanical System in Garage.
A. Protection from damage. Equipment shall not be installed in a location
where it is subject to mechanical damage unless protected by approved,
substantial barriers. Section M1307.3.1.
B. Elevation of ignition source. Heating or cooling equipment located in a
garage and which generates a glow, spark, or flame capable of igniting
flammable vapors shall be installed with the pilots and burners or heating
elements and switches at least 18 inches above the floor level. Section
M 1307.3
Venting and Combustion Air
73. All fuel burning equipment shall be provided with combustion air.
Appliances located within the building envelope shall obtain combustion air
from outdoors. Heating equipment located within the Building Envelope shall be
thermally isolated from the heated area. Chapter 17 IRC
74. Every appliance designed to be vented shall be connected to a venting
system complying with Chapter 18, IRC.
75. Every factory -built chimney, Type L vent, Type B gas vent, or Type BW
gas vent shall be installed in accordance with the terms of its listing,
manufacturer's instructions, and the applicable provisions of Chapter 18,
IRC.
76. Vent connectors shall be installed within the space or area in which
the appliance is located and shall be connected to a chimney or vent in
such a manner as to maintain the clearance to combustibles per Section M1803.3.4
and Table M1306.2 IRC. and Figure M1306.1 IRC
77. Type B or BW. Type B or BW gas vent shall terminate per M1804 IRC
Duct work
78. Duct systems shall be of metal as set forth in Table M1601.1.1(2) IRC
factory made air ducts complying with Chapter 16, IRC.
Joints and seams shall be substantially airtight by means of tapes,
mastics, gaskets or other means.
2021 WASHINGTON STATE ENERGY CODE:
El. Access Hatches and Doors. Access doors from conditioned spaces to
unconditioned spaces (e.g., attics and crawl spaces) shall be
weather-stripped and insulated to a level equivalent to the insulation on
the surrounding surfaces. Access shall be provided to all equipment which
prevents damaging or compressing the insulation. A wood framed or
equivalent baffle or retainer must be provided when loose fill insulation
is installed. Section R402.2.4. WSEC
INSULATION: All insulation materials, including facings such as vapor
barriers or breather papers, installed within floor/ceiling assemblies,
roof/ceiling assemblies, walls, crawl spaces, or attics shall have a
flame -spread rating not to exceed 25 and a smoke density not to exceed 450
Exceptions:
1. Foam plastic insulation shall comply with Section R316, IRC,
2. When such materials are installed in concealed spaces, the flame spread
and smoke -developed limitations do not apply to the facing, provided that
the facing is installed in substantial contact with the unexposed surface
of the ceiling, floor, or wall finish.
3. Cellulose insulation shall comply with Section R302.10.3 IRC
E2. Insulation Clearances. Where required, insulation shall be installed
with clearances according to manufacturer's specifications. Insulation
shall be installed so that required ventilation is unobstructed. For blown
or poured loose fill, clearances shall be maintained through installation
of a permanent retainer.
E3. Roofs/Ceilings. Open blown or poured loose fill insulation may be used
where the slope of the ceiling is not more than 3:12 and there is more
than 30 inches from the top of the ceiling framing to the underside of the
roof sheathing at the roof ridge. When eave vents are installed, baffling
of the vent openings shall be provided so as to deflect the incoming air
above the surface of the insulation. Baffles shall be rigid material,
resistant to wind driven moisture. Section R402.2.1.1 WSEC Refer to Section
R806 IRC for additional information.
E4. Walls. Insulation installed in exterior walls shall comply with the
provisions of this section. All wall insulation shall fill the entire
framed cavity. Exterior wall cavities isolated during framing shall be
fully insulated to the levels of surrounding walls. All faced insulation
shall be face stapled to avoid compression. Table R402.4.1.1 WSEC
Vapor retarders shall be installed on the warm side (in winter)
of the insulation Section IRC R702.7
E5. Floors. Floor insulation shall be installed in a permanent manner in
substantial contact with the surface being insulated. Insulation supports
shall be installed so spacing is no more than 24 inches on center.
Foundation vents shall be placed so that the top of the vent is below the
lower surface of the floor insulation. Section R402.2.7 WSEC
E6. Slab on grade floors. The minimum thermal resistance (R-Value) of the
insulation around the perimeter of unheated or heated slab -on -grade floors shall
be as specified in Table R402.1.1. The insulation shall be placed on the outside
of the foundation or on the inside of the foundation wall. The insulation shall extend
downward from the top of the slab for a minimum distance as shown in the table
or to the top of the footing, whichever is less, or downward to at least the bottom
of the slab and then horizontally to the interior or exterior for the total distance shown
in the table. A two inch by two inch (maximum) pressure treated nailer may be placed
at the finished floor elevation for attachment of interior finish materials.
Radiant Slabs. The entire area of a radiant slab shall be thermally
isolated from the soil with a minimum of R-10 insulation. The insulation
shall be an approved product for its intended use.
E7. Below Grade Walls. Below grade exterior wall insulation (cold side of
the wall) shall extend from the top of the below grade wall to the top of
the footing and shall be approved for below -grade use. Above grade
insulation shall be protected. Insulation used on the interior (warm side
of the wall) shall extend from the top of the below -grade wall to the
below -grade floor level. Section R402.2.8 WSEC
E8. Roof/Ceiling assemblies where the ventilation space above the
insulation is less than an average of 12 inches shall be provided with a
vapor retarder. Faced batt insulation where used as a vapor retarder shall
be face stapled. Single rafter joist vaulted ceiling cavities shall be of
sufficient depth to allow a minimum one inch vented air space above the
insulation. Vapor retarders are not required where the ventilation space
above the insulation averages 12 inches or greater or where the insulation
is installed between the roof membrane and the structural roof deck.
E9. Walls separating conditioned space shall have a vapor retarder
installed. Faced batt insulation shall be face stapled.
El0. Floors separating conditioned space from unconditioned space shall
have a vapor retarder installed with a one perm dry cup (4 ml.) rating or
less..
El 1. Ground cover of six mil (0.006" thick) black polyethylene or approved
equal shall be laid over the ground within crawl spaces. The ground cover
shall be overlapped 12" minimum at the joints and shall extend to the
foundation wall.
Exception: The ground cover may be omitted in crawl spaces if the crawl
space has a concrete slab floor with minimum thickness of 3-1/2 inches.
E12. Air Leakage Control. Seal all exterior openings Section R402.4
A. Exterior doors and windows shall be designed to limit air leakage into
or from the building envelope, except for assemblies that are required to
be of fire -resistive construction.
B. Exterior joints around windows and door frames, openings between walls
and foundation, between roof and wall panels; openings at penetrations of
util ity services through wall, floors and roofs; and all other openings
in the building envelope shall be sealed, caulked, gasketed, or weather
stripped. All other openings shall be sealed , caulked, gasketed or
weather-stripped to limit air leakage.
C. Site constructed doors and windows are not required to be tested, but
shall be made tight fitting. Fixed lights shall be stopped with salient
all around. Operating sash shall have weather-stripping working against
overlapping trim, and a latch which will hold the sash closed.
D. Recessed Light Fixtures. When installed in the building envelope,
recessed lighting fixtures shall be an Type IC rated and certified under
ASTM E283 as having an air leakage rate not more than 2.0 cfm
(0.944 L/s) when tested at a 1.57 pdf (75 Pa) pressure differential and
shall have a label attached showing compliance with this test method
all recessed luminaires shall be sealed with a gasket or
caulk between the housing and the interior wall or ceiling covering.
WSEC R402.4.3
E14. Duct Construction. All duct work shall be constructed in accordance
with standards RS-15, RS-16, RS-17, RS-18, RS-19, or RS-20, as applicable,
and the International Mechanical Code. Section R403.3 WSEC
E15 R403.1 At least one thermostat shall be provided for each separate
heating and cooling system. Programable per R403.1.1
ENERGY NOTES:
- DUCT TESTING REQUIRED PER WSEC R403.3.5
- BUILDING AIR LEAKAGE TESTING REQUIRED PER WSEC R402.4.1.2
(SEE NOTE THIS PAGE)
- HVAC CONTROLS WITH PROGRAMMABLE SCHEDULE PER
WSEC R403.1.1
- ALL PERMANENTLY INSTALLED LIGHTING
FIXTURES SHALL BE HIGH -EFFICACY PER R404.1
- INSULATION MARKERS SHALL BE PLACED EVERY 300 S.F. IN THE ATTIC
AND FACE TOWARD THE ATTIC ACCESS
PER WSEC R401.3:
A CERTIFICATE IS TO BE POSTED IN SPACE THE SPACE WHERE THE
FURNACE IS LOCATED, UTILITY ROOM OR ON AN APPROVED LOCATION
INSIDE THE BUILDING. WHEN LOCATED ON THE ELEC. PANEL, THE
CERTIFICATE SHALL NOT COVER OR OBSTRUCT THE VISIBILITY OF THE
CIRCUIT DIRECTORY LABEL, DISCONNECT LABEL OR OTHER REUD LABELS.
1. R-VALUES OF ALL INSULATION INSTALLED (ATTIC, FLOOR,
WALLS, DUCT WORK OUTSIDE OF CONDITIONED SPACE, ETC.)
2. U-FACTORS AND SOLAR HEAT GAIN COEFFICIENT (SHGC)
OF FENESTRATION
3. RESULTS FROM ANY REQ'D DUCT SYSTEM & BUILDING ENVELOPE AIR LEAKAGE TESTING
4. RESULTS FROM THE WHOLE -HOUSE MECHANICAL SYSTEM FLOW RATE TEST
5. TYPES, SIZES AND EFFICIENCIES OF HEATING, COOLING, WHOLE HOUSE VENTILATION
AND SERVICE WATER HEATING APPLIANCES
6, WHERE ON -SITE PHOTO VOLTAIC PANEL SYSTEMS HAVE BEEN INSTALLED
THE ARRAY CAPACITY, INVERTER EFFICIENCY, PANEL TILT, ORIENTATION AND ESTIMATED
ANNUAL ELECTRICAL GENERATION SHALL BE NOTED ON CERTIFICATE
7. THE CODE EDITION UNDER WHICH THE STRUCTURE WAS PERMITTED
AND THE COMPLIANCE PATH USED.
ALL CERTIFICATES LOCATED AT:
hftps:/Iwww.energy.wsu.edulbuildingefficiency/energycode.aspx
ALL HEADER MEMBERS ARE TO BE INSULATED WITH R-10 RIGID
INSULATION UNLESS THE HEADER MEMBER IS 5-1/2" IN WIDTH
FRESH AIR IN HABITABLE ROOMS SHALL BE PROVIDED THROUGH
WINDOWS, DOORS, SKYLIGHTS, LOUVERS OR OTHER APPROVED
OPENINGS TO THE OUTDOOR AIR. SUCH OPENINGS SHALL BE
PROVIDED WITH READY ACCESS OR SHALL OTHERWISE BE READILY
CONTROALLABLE BY THE BUILDING OCCUPANTS. THE OPENABLE
AREA TO THE OUTDOORS SHALL NOT BE LESS THAN 8% OF THE
FLOOR AREA BEING VENTILATED. R303.1
ALL DOORS ARE TO BE UNDERCUT 1/2" WHERE SEPARATED FROM
EXHAUST SOURCE
WALL CORNER INSULATION:
CAVITIES WITHIN CORNERS AND HEADERS OF FRAME WALLS SHALL BE
INSULATED BY COMPLETELY FILLING THE CAVITY WITH A MATERIAL
HAVING A THERMAL RESISTANCE OF R-3 PER INCH, MINIMUM.
NO VOIDS
PIPE INSULATION NOTE
R403.5.3 WSEC
INSULATION FOR HOT WATER PIPES, BOTH WITHIN AND
OUTSIDE THE CONDITIONED SPACE, SHALL HAVE A MINIMUM
THERMAL RESISTANCE OF R-3
EXCEPTION:
PIPE INSULATION IS PERMITTED TO BE DISCONTINUOUS
WHERE IT PASSES THROUGH STUDS, JOISTS OR OTHER
STRUCTURAL MEMBERS AND WHERE THE INSULATED
PIPES PASS OTHER PIPING, CONDUIT OR VENTS,
PROVIDED THE INSULATION IS INSTALLED TIGHT TO
EACH OBSTRUCTION.
dan@brobstdesignworks.com
206.409.6690
W
w
o
H
O
O
z
U
UJ06
�
Q
U
�
�
C,7
IT-
Of
N
W
N
Z
L.I.J
i
E-I
11-4
Wo
U
���F1a►
SCALE
6.15.2024
DALE
2021 CODE
COMPUTER FILE NAME
N1
ti
00
O
00
O
0
Z
J
SHEET NUMBER
7l_.1 Cove Cc -prance Caeofsior A3EC 2CIS
Al 3J Cooe Co -plane Caeudmw W3EC 2011
W3J Cane Cc-p once C3cL-31Cr .SCE:::'5
Cerrh,ry Comr•uuses
•IOn/es 3lreet-Cherels
a',-0 21e_5
,IBCob Moon!►. HE43 Rill adS?0ls5
IG8 tmdecaors. CtG
;KOtIh�Ca-ew0lC'a7rS com 36C ' 13.185E
ANALYSIS SET 11P
it
IN
Ravlaw reauttld for ouvem entrlsc .:,00m- Flat'V ourto l CeeMtp%
UA Reductcr - 42 76. Procosed J A Is bel er Tian paselne by 16%
UA reduction -%*M pem"t large'. cr . elected 000M 1
W a1do- area :s 10% of floor we a
Whoe Mouse 1149MMMIX0 VRtaaOpn Ar%M Rate: 925 GFU TIM Rut Mine Percent Of 1100%. UnbalMCed. Net r!ISOONa
LUMN wm asrBnle toll! m44111tt_i_t_ticl W~. 172 CFM225
ewtvw* seta !twee � mrrwlala v..c! 1t wut► ac -� =a.IRb r pc•. •� •: s rr f►tL a W •wrwM ter r..+ Ar•�
What Does ooatpb WO 041108Y an you la%Nlaf U-FaMOr Caw atawaa Pedh (TI Im UA AftMNNV*
Pro)•ol Buliding Typal 11ew Condrustleo
Ooouparwy Type? RB Mob tam.9l homes and d ass
Coen VOMAD t WBEC 2621 iWaECJ1 Rev DM 2023. Mtge:: wwra eDaors 0ort+tae:eabultRtwi8:3
Claccdloetlon: Wedlum Owe "no Uri - 2155 tie. 1t
Based" Dec"Mon: Code BasNne - Marmon baserine wlndzir area,_- 15% = rr :• area Cer : o14r ' UA re,:,_:cr coculab1 (Sacb" R402.1 51
Abort Vote Sol*~: lido exempt ammo or door areas
RESULTS - Cornpartaon of 5864I0 and Pf pMO DS@W _
Component Perfc•rmanoe, P coo jpanol" Boseane Peapio" oveon
U Area UA U Areas UA
Doors U 2
over"ead e"Zong U 2
V erttoa I O taz,tlp U a
Flatlr'auMod C@OIW4a Y 2
lVall Iabone Craidol Us
Fioorc over Crawlaeaoa U 2
s lab on Ora" F a:
Below tirade "a U 2
Bo•ow Oraos a:ab F =
0.3M
39 113
gip
0
OD
0.3M
2D7
621
0n'a
1A
26-8
glyss
2,w1
1263
OA2!
1.1f!
34-2
03t0
0
0-0
AMA
0
0.
sUA
0.170
36
SA
0
OD
Oise
20'
S13
0.019
1.199
22.2
OAA!
2,3t31
1.1"
tf27
CA25
30.0
0
0.11
0
0.0
0
OD
' Vawes from Table R.&C2 1 _' Oct 2C23t
Baaaart* UA Total MAN PropsceC UA Total 223.1
Roatdrea Creel le% 8-0 Prepflced Crean% 1A horn Tape%.06- and 406.
VA Pertlent Roduabia 16.1%
UA Redasl8an 42.8
11 the Proposed UA s the Target UA, and the Pfcpoced Credits from Table 404 are : M+oce roput*d In Sootion a404, then the none meet% tne WBEC.
Tabu R4062 Enarav Eausnutlon Cradlta
COr neanv system amg a neat owro Rffi nee-.- -em-3-.mncwes for :.e
4 ealijo `e'er Itlad In Table C-401 3: 1 Of Tw4e C4L-3 32, 9 CAR .A;r to NOW neat Vat1MSM RoWNWMt MGM Pump of Ar4c,-
pu-o units that are con!prrea b orehOe Dar healing and cooanp and are -seed In waaar Maas PUMP
lacc orlwce a" AMR1 SSQ S90
FuelNormalttalbnl EnergyC►adfa TOW Cmdlb
310 1 50 1.0
Opbm Nd -
CaLpri
ssssal OP"M
sailor Creates
w1ar DO&W% 110n as sehom d Opttwtav
I ErCert fiu'•aMy Eevelon o6Jon 1 2
1 0
Persc-ve.e co^rolrce W -sme 4C_ 1 3 U-3.25 vermst
1trletw for ' 34-3a fipors or R-13 permMN 6ltrtrt rfsutmed
&ap Or 15% McLX:on in LA per sec:un Rifj_` 1.5
3 1-3 10
Air :.eatage Csradl and Elnclera'verDalton
H gM E-clent l .I1, AC
ODO M 2-0
Air Sou roe mlcted Meet P,.ry rr.' Un M3PF2 of 10 1143PF 01
11). raft demo temp Is 23F or be10e 3 cad ornate varatlle
c1MK�tNytpu^np Kre0lWee.
1.0
3 11
Hqn E•clerxr - AC C-:aM Ther-.ostst
0.0
1-12011 WSEC1=18 C-OMOL nce/br-1r.2D21'Cax C ' o0 arse C-scwaldrlw
'A'__ Coot Cc-D'ance C-3C1r41a A3EC 2019
Sum of Area and UA
3.26 2C2a
_
04911 E Nc ) ftVAC DatEtcon 3rstem
ova" 4.1
C 5
Docts otstrbubon rystem m contltioned space per R403.3.2
Electnc res.stance. RTaronc eutsess and pas !ed rysterrrs <
90% A=UE systems not permlled
5 1
Ef'cere Amer tlemlrlp Oran Heat Recovery
C 0
52
El-cen Water Heaeno Comoact Mot Wow Dslrtuson
OpOon 4-2
03
COmpactHN A31e`D%V Mt`Cr 3y-ter^ Vas •OUMebelreen
hat source and lrtie 1s 16 Oz or section RAC3.52. on
0lmand c1rc PN-p lnay at revues
Extols heal Durnp water hater-•ettrng KEEA Tler 3
5 3-5-8
EPciert A seer «4eacn0
Opobal A's
20
6
Renee -we rears Energy
law"
OD
Acplan;e Pactage
ap�lls
00
�
•Rehr to 'rysEC 2016 Tat* P.4,A 2 for oompttte optlon dKorlpJonc and reduuementr
1'tM18WSEC1M18Como Uncelbr- 'CodeGOntramCRQKYlalonW3U C3_2C2tr02a03�•tMRltin
W 3U Code Co,oksrice Caeulator .V.EC 2010
►" Coiling - it Fasts UA
ID _ Oatort OB" 811L U Ma
V. AIN Rat worded JONI 0021 1.:. ` : 20 18 1 A-1.4) 10-3 0.025 99' 2s
: _a GA R28 vordod Jold CM21 12. 1.3. 2018 1.8-1-41 10-1 B-03 a s
Sala of An* eats
SIaO on Oraee t o" than 2 Mt below
Plan C err pont'd 0r sate•
M Jscorlpticn W F rout FP
low of PO WAK Bad FP 01
5.10. arads waft and slats = _
PIN! COmpono d Blab was -- - wN 1 wasl Blab 8� elm►
w Doserlpbon a"" Red U Ana UA F PIrt11n UA
Bunt of Area, Length and UAI ;40
Links to Download Fora, Cbfdtlbb ant] Other NfNoUircm Lb1b
Como ""DoCertKbate CC at I.n • &rr•r.-.r .n_tr�»rns
ine,wation Certhlosto for FeWemw New Conctructlon rlsJator Ctrn'Y_xe
D not TKtin 0 Affsdavft
£alsti0 :on5lnrCEa kf. tr t F.I•trn
Ves Corsrrctcr Atrda'rt his
Proeertpbve CIw00tt%t1or2011 W8EC P'esc'Lece Crest -at
ANaeanons tRamodorl Worsehoot Arvktreet
EER SEER2 COP MSPF2 Converter 1112: awr a=ena reerra :ram- der meet^tcc ser^trsarrcrw renew
Retplcrements
Condroonod Floor Area 2.fl5 an IL
Nurnper of Bedrooms _
o Run -TV" Poiont In Egon 4-How Bagman! lBay
K "To %yelotw 111alan"67 - roalarteed
is the syetsen OlatMule ? D4trltvt&d
Vorttaatbn Cots* ao*tlon C11acter t5
Whcle Houct Ysor.anloal Vt1buill n At4ow Rhea q]CF11
shoe OWtnoutlon a %teal CmMadOf? ° or
MAC ThIf" D1atr7dtRbrl s OpwdsM No-go t=aoal _
Is this a hyoronlo iwatlro %)Stem? Nc
_ODat Wn of :lusts COIIQllO1Md epees 1
-cost on of A.V "angler Conglow" spaiss
It Duet Tatlllf0 MSNbN} YM
W a. Imam! Duet Loataos:
Maylmwr local measured duct leakage per MuMfe bet IN C Mm25 per so. tt
Wrmtr- ahowKle total measured duct teseape 172 ;CFM26
.A � of 10 tatof rear• ducts and S let of stpDY tsa0s are sloeled b Ot totale0 orrsne Of tx ptAtlrlp Tennis elHH00e. Y ncJatd and fasted per RAM 3
snow H.!♦tlnIs stern StrI ? t
HeabrrtQ Srshnt Sizing - Prgpved Design Try Out 0egt OuM Ms NVAC Sway Toat- Peas- •beaeftJM1* Ccm,.rsdarces a:-S;0M2-oa
N*w*st Weather station I n.hai s
Indoor Design Temperature 70 F
Outdoor Design Teen paratune 21 F
0*0gn Temperature Dmrrenoe I:.TJ 49 F
Conditioned Floor Area Proposad D*s10h 2.155 ft2
n v�vrc v>=t wca - rasMtreev tAlsawa
Conditioned Foot Ater Pro w"d Dols ton - -- :7 R
0Iat4Rleatlon 1/eQor pwe'rq Jnt!
Not",
1/ MCSI GIa21N S
Pian COlapaaaa0 ONZ" %Vl t
Dommvftn Ibt U Yt. Fed
t XO
2 XCI
U=016 {2021 12: 28/8 1.4)
U=0 !612021 12; MA IA)
7aoe ao6�
Tabr406.2
02s
4
4
025
2
6JW
3 330
U=0.26 MI 1.2' 2011 1.4
Taus406;
gas
1
6
4 x0
! z0
UZO-24 J a21 /2 281S 1 4;
U=0-26(MI I_t241s 14)
Tae,e4062
Ta *4o62
62s
2
3
925
1
_
6
i
B
1C
News; b
Bain of Ma and UA
V►r%WSMdng Area W'elanted U
Na111M1 04UIng and DOM Are,! WetOriled U
64.3 16 CO
63-D 5 CO
41.D 'C.25
I" 450
24A 6 CO
Wass IAaove 0rede; _ y
Plan C+aa/wf1! 1ara11
D I per Y I P•*t Area UA
EXT IR 23 Davit • RD foam PIT 271 BN LaP AM A 0 04! • 5#a 9i
3 R23 DavtlyRs foam INT 2x81W Lap &V A
32 ,213-14 I I; =I$ WSEC12018 COmpashceltRnV=?'Code Cow -prance Cacu+alon W'3U_G32021_2II2aC32 �u>saetsm
--------- I i W_..Cade: - arceCaeovior W2EC2019
CoodkkKea VOIUMO
�- �ft3 Vdftsll wAtoning Del rn2 he1pM of 4-611. = 18416 n3
Lane tear• ft uw era h ji d E! 1 ,are•d'.e1rn
M VAC System Type
we at P tar
L000&MaMVACDtctrtbutlu ayt:tom
CondmonedOPKC
St:m of UA, hwtudlre stem sit door and wlhdow
223
Envelope Meat Load
tC,l31 Btu I Matt
go" d to A Al
Alf Lsebopa Had Leal)
! 6!4 Bbr r Mow
11'Meew" a 0a1 9.11) x olap
■ufd" Daalgn M d Least
20.i24 Out # Now
Ar Lauer. • Lftwu to mere Low
BufaMlp and Dad 6*9 Leas
20 6: l nu 1 Nor
y dvMmcned w www"Ni wal wm. 1►ff. of MiAMM 4ndLane R I 1
P w !A M=Md w andawwe Was w solar a." d Iv/N 4owl La X 1
masblma Meal Eadpwaat ON%"
701
Still! our
MILM" dt* 010111wd Lae* A 12110 kOd PORTIM
7.0
p.wty 0" Dias "ad La a t ad 11. dI I* w talearlw
R*ha to WSEC A412.1
ROW to WBEC RA02-1
Pere- l- h1 c.: P40? `.
3.26 2=4
dan@brobstdesignworks.com
206.409.6690
U)
W
W QO
W
O CnU z
Z Q
WC/) C:)J
-CL
04
CDC/3 V
Q �
wes
or
Z
W
ti
00
0
00
M
O
W
Z
J
�
r
Fewal���.+/
F--�
O
N
lam ---I
1�4t
W
Wo
C/)
U
Q
�
Q
00
0
r
r
W�N7A
SCALE
6.15.2024
DALE
2021 CODE
COMPUTER FILE NAME
N1 11
SHEET NUMBER
I_`31BW_ECZC1BComp+ancefor-a'= iCoseCor-punceC.aclramr-W3U_C3=:
3'26:=.I
a^:e':-_:_ VJCJ sOeCor-*IanCeCacur;aaonW31+_C32C_1_ aC3�.BOlO!!tm
3' 25 2C:a
2021 IRC CODE
GROUP R-3 OCCUPANCY
Wind and Snow load factors may vary based on geographical location.
GENERAL
DEFINITION: Habitable Space (room) is space in a structure for living,
sleeping, eating or cooking. Bathrooms, toilet compartments, closets,
halls, storage or utility space and similar areas, are not considered
habitable space. Section R202, IRC
1. Ceiling Heights. IRC R305.1
Habitable rooms, hallways, corridors, bathrooms,
toilet rooms, laundry rooms and basements shall have a ceiling height of
not less than 7 feet. The required height shall be measured from the
finished floor to the lowest projection from the ceiling.
Exceptions:
1. Beams and girders spaced not less than 36" on center may project not
more than 78" from finished floor
2. Ceilings in basements without habitable spaces may project to within
6'-8" of the finished floor, and beams, girders, ducts or other
obstructions may project to within 6'-4" of the finished floor.
3. Not more than 50% of the required floor area of a room or space is
permitted to have a sloped ceiling less than 7 feet in height, with no
portion of the required floor area less than 5 feet in height.
4. Bathrooms shall have a min. ceiling height of 6'-8" over the fixture
and at the front clearance area for fixtures. A shower or tub equiped with a
showerhead shall have a min. ceiling height of 6'-8" above a min. area
30"x3O" at the showerhead.
LIGHT, VENTILATION AND SANITATION
1. All habitable rooms shall be provided with aggregate glazing area of not less
than 8% of the floor area of such rooms. Natural ventilation shall be through
windows, doors, louvers or other approved openings to the outdoor air. Such
openings shall be provided with ready access or shall otherwise be readily
controllable by the occupants. IRC Section R303.1
Exceptions provided per IRC Section R303.1
2. Ventilation. Group R Occupancies shall be provided with ventilation
systems which comply with Section 303
The point of discharge for mechanical ventilating
systems shall be at least 3 feet from any opening which allows air entry
into occupied portions of the building. M1506.3
Refer to additional exhaust ventilation requirements in Section R303.3
for bathrooms and water closets. See Chapter 15 for kitchens & laundry room requirements
3. Range &
Dryer Vents.
Ducts used for domestic
kitchen range ventilation
and clothes
dryers exhaust
shall be of metal and
have smooth interior
surfaces. Ducts shall be
substantially airtight and shall comply with the
provisions of
Chapter 15,
IRC. Exhaust ducts shall
terminate outside the
building and
be equipped
with back draft dampers.
IRC Sections M1501, M1502 & M1503
4. Moisture Exhaust Ducts. Moisture exhaust ducts for domestic clothes
dryers shall terminate on the outside of the building and shall be
equipped with a back -draft damper. Screens shall not be installed at the
duct termination. Ducts for exhausting clothes dryers shall not be
connected or installed with sheet metal screws or other fasteners which
will obstruct the flow. Clothes dryer moisture exhaust ducts shall not be
connected to a gas vent connector, gas vent or chimney. Clothes -dryer
moisture exhaust ducts shall not extend into or through ducts or plenums.
Length Limitation. Unless otherwise permitted or required by the dryer
manufacturer's installation instructions and approved by the building
official, domestic dryer moisture exhaust ducts shall not exceed a total
combined horizontal and vertical length of 35 feet, with reductions for
elbows per IRC TABLE M1502.4.6.1
IF FITTINGS ARE USED, THE MAX. LENGTH SHALL BE REDUCED TO BE PER DRYER
OR THE DRYER EXHAUST DUCT POWER VENTILATOR MANUFACTURER'S INSTALLATION
THE DUCT SHALL BE A MINIMUM OF 4" DIAMETER, 0 FMETAL OR APPROVED MATERIAL
WITH SMOOTH SURFACE
5. Water Closet Space Requirements. The water closet stool in all
occupancies shall be located in a clear space not less than 30 inches in
width, with a clear space in front of the stool of not less than 24"
6. Tub & Shower Walls. When gypsum is used as a base for tile or wall
panels for tub, shower or water closet compartment walls, water- resistant
gypsum backing board shall be used. Regular gypsum wallboard is permitted
under tile or wall panels in other wall and ceiling areas
Bathtub and shower floors and walls above bathtubs with installed shower heads and
in shower compartments shall be finished with a nonabsorbant surface. such wall
surfaces shall extend to a height of not less than 6 feet above the floor
Water-resistant gypsum board shall not be used in the following locations:
a) Over a vapor retarder.
b) In areas subject to continuous high humidity, such as saunas, steam
rooms or gong shower rooms.
c) On ceilings where frame spacing exceeds 12 inches on center.
FOUNDATIONS
7. Slope Limits. Cut slopes for permanent excavations shall be not steeper
than 2 horizontal to 1 vertical and slopes for permanent fills shall be
not steeper than 2 horizontal to 1 vertical unless substantiating data
justifying steeper slopes are submitted. Deviation from the foregoing
limitations for slopes shall be permitted only upon the presentation of a
soil investigation report acceptable to the building official.
8. Setbacks from Slopes. Foundation setbacks from ascending and
descending slopes shall comply with IRC Figure R403.1.7.1
9. Stepped Foundations. Foundations for all buildings where the surface
of the ground slopes more than 1 foot vertical in 10 feet horizontal shall
be level or shall be stepped so that both top and bottom of such
foundation are level. IRC Section R403.1.5
10. Pier Footings. Individual concrete pier footings shall project minimum
of 8 inches above exposed ground unless the columns or posts are of
approved wood of natural resistance to decay or of treated wood.
Exterior concrete piers shall be 12" minimum below grad or to bearing soil
whichever is greater
11. Column and Posts Supports. Columns and posts located on concrete or
masonry floors or decks exposed to the weather or to water splash or in
basements and which support permanent structures shall be supported by
concrete piers or metal pedestals projecting above floors unless approved
wood of natural resistance to decay or treated wood is used. The pedestals
shall project at least 6 inches above exposed earth and at least 1 inch
above such floors.
12. Under -floor Clearance & Access. When wood joists or the bottom of
wood structural floors without joists are located closer than 18 inches or
wood girders are Located closer than 12 inches to exposed ground in crawl
spaces or unexcavated areas located within the periphery of the building
P P P Y 9
foundation, the floor assembly, including posts, girders, joists and
subfloor, shall be approved wood of natural resistance to decay as listed
in IRC Section R317.1 or treated wood. Min. 8" clear exposed ground to
wood framing members that rest directly on concrete R317.1(2)
When the above under -floor clearances are required, the under -floor area
shall be accessible. Accessible under -floor areas shall be provided with a
minimum 18 inch-by-24 inch opening unobstructed by pipes, ducts and
similar construction. All under -floor access openings shall be effectively
screened or covered. Pipes, ducts and other construction shall not
interfere with the accessibility to or within under -floor areas.
IRC Section R408.4
13, Under -floor Ventilation. Under -floor ventilation, minimum net area of
1 square foot for each 150 square feet of under floor area, one opening shall
be located within 3' of each corner of the building and shall provide cross
ventilation. The openings shall be covered with one -quarter inch corrosion
resistant wire mesh.
IRC Section R408.2
FRAMING
14. Quality & Identification. All lumber, wood structural panels,
particleboard, structural glued -laminated timber, end -jointed lumber,
fiberboard sheathing (when used structurally), hardboard siding (when used
structurally), piles and poles regulated by this chapter shall conform to
the applicable standards and grading rules specified in the UBC and shall
be so identified by the grade mark or a certificate of inspection issued
by an approved agency.
All preservative treated wood required to be treated under Section R317
shall be identified by the quality mark of an approved inspection.
15. Foundation Cripple Walls. Foundation cripple walls shall be framed of
studs not less in size than the studding above with a minimum length of
14 inches, or shall be framed of solid blocking. When exceeding 4 feet in
height, such walls shall be framed of studs having the size requirements
for an additional story. Solid blocking or wood structural panels may be
used to brace cripple walls having a stud height of 14 inches or less.
Cripple walls having a stud height exceeding 14 inches shall be braced in
accordance with Section R602.9, IRC.
16. BEARING: the ends of each floor joist shall have not
less than 1-1/2 inches of bearing on wood or metal, nor less than 3 inches
on masonry except where supported on a 1 x 4 ribbon strip nailed to
adjoining stud. Section R502.6, IRC,
17. Supporting Bearing Partitions. Supporting bearing partitions
perpendicular to floor joists shall not be offset from supporting girders,
walls, or partitions more than floor joist depth. Floor joists under and
parallel to bearing partitions shall be doubled.
18. Cutting, Notching and Boring.
A. Notches on ends of rafters and ceiling joists shall not exceed
one-fourth of the depth. Holes bored in rafters or ceiling joists shall
not be within 2 inches of the top or bottom, and their diameter shall not
exceed one-third the depth of the member. Notches in the top or bottom of
the rafter or ceiling joist shall not exceed one -sixth the depth and shall
not be located in the middle third of the span. Sections R602.6, IRC.
B. In exterior walls and bearing partitions, any wood stud may be cut or
notched to a depth not exceeding 25% of its width. Cutting or notching of
studs to a depth of 40% of the stud width is permitted in non -bearing
partitions. Section R602.6, IRC.
C. Notches in sawn lumber beams shall not exceed one -sixth the beam depth
of the member and shall not be located in the middle third of the span.
Notches at the ends shall not exceed one-fourth the beam depth. The
tension side of sawn lumber beams of 3-1/2 inches or greater thickness
shall not be notched except at the ends.
D. Manufactured glue laminated beams may not be notched, cut or bored
without submission and approval of substantiating calculations from a
licensed Structural Engineer.
Cutting, Drilling, Notching Structural members shall not be cut, bored
or notched in excess of the limitations specified in IRC Sections: R502.8.1,
R602.6, R802.7
19. Bridging and Blocking
Wall Framing. Bridging. Unless covered by interior or exterior wall
covering or sheathing meeting the minimum requirements of this code, all
stud partitions or walls with studs having a height -to -least thickness
ratio exceeding 50 shall have bridging not less than 2 inches in thickness
and of the some width of the studs fitted snugly and nailed thereto to
provide adequate lateral support.
Floor Joists. Blocking. Floor joists shall be blocked when required by the
provisions R502.7.1 IRC
Roof Framing. Blocking. Roof rafters and ceiling joists shall be supported
laterally to prevent rotation and lateral displacement. R802.10.3 IRC
20. Post -Beam Connections. Where post and beam or girder construction is
used, the design shall be in accordance with the provisions of this code.
Positive connection shall be provided to ensure against uplift and lateral
displacement.
21. Manufactured Roof Trusses --Sections R802.10.1, IRC.
A. Trusses. Stress analysis and drawings/details shall be stamped by an
approved State of Washington Registered Engineer.
Drawings/details shall be on job site for framing inspection.
Pre -manufactured trusses shall be identified by manufacturer's stamp.
Girder and field identification of light metal plate connected trusses
is required.
Information branded, marked, or otherwise permanently affixed to each
truss shall contain the following:
1) identification of the truss manufacturing company;
2) the design load; and
3) the truss spacing.
Engineering data and details shall be approved by the building official
before any field cuts or truss alterations.
All roof trusses shall be so framed and tied into the framework and
supporting wails so as to form an integral part of the whole building.
Roof trusses shall have joints well fitted and shall have all tension
members well tightened before any load is placed upon the truss. Diagonal
and sway bracing shall be used to brace all roof trusses.
B. Girder and Field Assembled Truss. Engineered stress analysis and
details shall be submitted to building division for approval.
C. Use approved/applicable truss support hangers.
22. Wood Exposed to Weather. All wood exposed to weather, such as wood
used for deck framing including decking, railings, joists, beams, and
posts shall be naturally durable wood or wood that is preservative treated
in accordance with AWPA U1. Section R317, IRC.
23. Guardrails. When decks, landings, stairs, ramps or porches are more
than 30 inches above grade or floor below, the building shall be protected
by a guardrail not less than 36 inches high with intermediate members
spaced such that a sphere 4 inches in diameter cannot pass through.
Section R312, IRC
24, Decks. Decks 30 inches or more above grade require a permit. All
decks must be designed and constructed in accordance with
Section R507 IRC
Solid Sheathed Decks and Roofs. Solid sheathed decks and roofs shall be
sloped a minimum 1/4 " per foot. When decks or roofs are not sloped to
drain over deck or roof edges, roof drains in combination with overflow
drains) and/or scupper(s) shall be installed. R903.4, R903.4.1 IRC
25, Roofs. Application of roof covering materials shall be in accordance
with Section R903 IRC.
26. Roof Ventilation. The net free ventilating area of enclosed rafter or
attic spaces shall be not less than 1/150 of the area of each space to be
ventilated, except that the area may be 11300, provided that 50% of the
required ventilating area is located at least 3 feet above eave or cornice
vents with the balance being provided by the eave or cornice vents, or if
a vapor retarder not exceeding a 1 perm rating is installed on the warm
side of the attic insulation. The openings shall be covered with
corrosion -resistant metal mesh with mesh openings of 1/4 inch max.
& 1/16 inch min. Section R806, IRC
27. Flashing & Counter -flashing. At the juncture of the roof and vertical
surfaces, flashing and counterflashing shall be provided per the roofing
manufacturer's instructions and , when of metal, shall not be less than
0.019- inch (No. 26 ga. galvanized sheet) corrosion -resistant metal.
Section R903.2, R903.2.1, R903.2.2 IRC.
28. Attic Space Access Opening. Attic spaces with 30 inches or more
in vertical height and an area of 30 square feet or greater.
shall be provided with an access opening 22 inches by 30
inches. The opening shall be located in a corridor, hallway or other
readily accessible location and have at least 30 inches head room. Section
R807.1 IRC
EXTERIOR WALLS
29. Exterior Wall Coverings. Exterior wood stud walls shall be covered on
the outside with materials and in the manner specified in Section R703, IRC
30. All weather -exposed surfaces shall have a weather -resistive barrier to
protect the interior wall covering. Section R703.1 IRC
31. Anchored veneer shall comply with the provisions of Section R703.8,
and Table R703.8(1) & (2), Figure R703.8
32. Veneer support shall conform to all standards in Section R703.8.2 IRC
GARAGE / CARPORT (occupancy separation)
33. The garage shall be separated from the residence and its attic
area by not less than 1/2" type "X" gypsum board applied to the garage side.
Garages beneath habitable rooms shll be separated from all habitable rooms
above by not less than 5/8" Type X gypsum board or equivalent. Where
the separateion is a floor -ceiling assembly, the structure supporting the
separateion shall also be protected by not less than 1/2" gypsum board
or equivalent.
34. Doors between the garage and residence shall be equipped with solid wood
doors not less than 1-3/8" in thickness, solid or honeycomb core steel
doors not less than 1-3/8" thick, or 20-minute fire -rated door.
Door shall be equipped with self closing hinges
35. In areas where motor vehicles are stored or operated, floor surfaces
shall be of noncombustible materials & slope to move liquid away.
36. An occupancy separation need not be provided
between residence and a carport
having no enclosed uses above, provided the carport
is entirely open on two or more sides.
MEANS OF EGRESS
DEFINITIONS: A means of egress is an exit system that provides a
continuous, unobstructed and undiminished path of exit travel from any
occupied point in a building or structure to a public way. Such means of
egress system consists of three separate and distinct elements: 1.) The
exit access, 2.) The exit, and 3.) The exit discharge.
Public way is any street, alley, or similar parcel of land essentially
unobstructed from the ground to the sky that is deeded, dedicated or
otherwise permanently appropriated to the public for public use and having
a clear width of not Less than 10 feet.
37. Exterior Exit Door. Buildings or structures used for human occupancy
shall have at least one exterior exit door with dimensions of 3 feet by 6
feet, 8 inches. Sections R311.2, IRC.
38. Hallways. Width. Hallways shall not be less than 36 inches wide.
Section R311.6, IRC.
39, Door Landing. A floor or landing is required on each side of an
exterior door. The door may open at a landing that is not more than 7-3/4"
inches lower than the floor level, provided the door does not swing over
the landing. The landing shall be 36 inches in length minimum. Section
R311.3 IRC.
40. WINDOW EGRESS
IRC R310.1: Emergency escape and rescue required:
Basements, habitable attics and every sleeping room shall have at least one
operable emergency escape and rescue opening. Where basements contain
one or more sleeping rooms, emergency egress and rescue openings shall be
required in each sleeping room. Where emergency escape and rescue openings
are provided they shall have a sill height of not more than 44 inches above the floor.
Where a door opening having a threshold below the adjacent ground elevation
serves as an emergency escape and rescue opening and is provided with a bulkhead
enclosure, the bulkhead enclosure shall comply with IRC Section R310.3.
The net clear opening dimensions required by this section shall be obtained by
the normal operation of the emergency escape and rescue opening from the inside.
Emergency escape and rescue openings with a finished sill height below the
adjacent ground elevation shall be provided with a window well in accordance with
IRC Section R310.2. Emergency escape and rescue openings shall open directly
into a public way, or to a yard or court that opens to a public way.
Exception: Basements used only to house mechanical equipment or storm shelters
and not exceeding total floor area of 200 square feet
Where the dwelling is equipped with an automatic sprinkler system
installed in accordance with section P2904, sleeping rooms in
basements shall not be required to have emergency escape and
rescue openings provided that the basment has one of the following:
- one means of egress complying with section R311 and one
emergency escape and rescue opening
- two means of egress complying with section R311
R310.2.1: Minimum opening area. All emergency escape and rescue
openings shall have a minimum net clear opening of 5.7 square feet.
Exception: grade floor openings shall have a minimum net clear opening of 5 s.f.
R310.2.1: Minimum opening height. The minimum net clear openings
height shall be 24 inches.
R310.2.1: Minimum opening width. The minimum net clear
opening width shall be 20 inches.
R310.1.1: Operational constraints. Emergency escape and rescue openings
shall be operational from the inside of the room without the use of keys,
tools or special knowledge.
MISCELLANEOUS
41-A. Smoke Detection Location. A smoke detector shall be installed in each
sleeping room and outside each separate sleeping area in the immediate vicinity
of each bedrooms. When the dwelling unit has more than one story and in
dwellings with basements, a detector shall be installed on each story and in
the basement. Smoke alarms shall be installed not less than 3' horiz. from the
door opening to a bathroom with a shower or tub unless this would prevent
placement required by R314.3. See Section R314.3.1 for placement of smoke alarms
near cooking appliances. Not less than 20' for Ionization type, not less than 10'
ionization with an alarm -silencing switch or not less than 6' for a photoelectric type.
41-B. Carbon Monoxide Alarms. A Carbon monoxide alarm shall be installed
outside of each separate sleeping area in the immediate vicinity of the bedrooms.
Where a fuel burning appliance liance is located within a bedroom or its attached bathroom
a carbon monoxide alarm shall be installed within the bedroom. R315.3
Alarms shall be listed as complying with UL 2034 and installed per manufacturer's
listing. R315.2 WAC, R315.1, R315.4 WA. State ammendment
FACTORY BUILT FIREPLACES
Factory built fireplaces shall be listed and labeled and shall be
installed in accordance with the conditions of the listing. Factory -built
fireplaces shall be tested in accordance with UL 127. R1004.1
Fireplaces shall comply with all provisions of section R1004
42, Installation of vented gas fireplaces (decorative appliances) shall be in
accordance with the manufacturer's installation instructions.
And shall comply with all standards of Section G2434 (604) IRC
43. Gas Fire Log Lighters. Approved gas fire log lighters shall be
installed in accordance with manufacturer's installation instructions.
Section G2433.1
STAI RWAYS
44. Usable space under stairs shall have walls and soffits (on the
enclosed side) protected as required with 1/2" g.w.b at min.
45. Fireblock Stairs. Between stair stringers at top and bottom and along
and in line with the run of the stairs between studs.
46. Stairways. Section R311.7 IRC
Maximum rise 7-3/4" inches; minimum run 10 inches; headroom minimum
6 feet 8 inches; minimum width 36 inches.
Handrails to have ends returned and placed minimum 34 inches, maximum 38
inches above tread nosing. Unless designated for the disabled, the
handgrip portion of handrails shall be not less than 1-1/4 inches nor more
than 2 inches in cross -sectional dimension or the shape shall provide an
equivalent gripping surface.
The handgrip portion of handrails shall have a smooth surface with no
sharp corners. Handrails projecting from a wall shall have a space of not
less than 1-1/2 inches between the wall and the handrail.
Exit Facilities. Stairs and exit balconies shall be positively anchored
to the primary structure at 8 feet on center max. or be designed for
lateral forces. Such attachment shall not be accomplished by use of
toenails or nails subject to withdrawal.
GLAZING
47. Safety Glazing. Safety glass must comply with Section R308 IRC
a a W
dan@brobstdesignworks.com
206.409.6690
W
W O
O
U �
U
r LU
N z
O W
N
ti
00
O
00
M
�-I O
� O
W Z
J
Eq 'a o
N
W
w � �
Q
U
C0
Q
00
0
co
REVISED
SCALE
4.6.2024
DALE
2021 CODE
COMPUTER FILE NAME
N2
SHEET NUMBER