HomeMy WebLinkAboutPULSE HEART CLINIC FAPWe] VAN-] SMA N Symbol Legend SYMBOL DESCRIPTION MANUFACTURER PART NUMBER MODEL QUANTITY NAc HPF-PS10, Power Supply, Remote Charger, 10A, 120VAC, Red Enclosure HONEYWELL PRODUCTS HPF-PS10 HPF-PS10 1 L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL SYSTEM SENSOR P2WL P2WL 1 I\�O\ SWLED, Strobe, Wall, White, L-Series SYSTEM SENSOR SWLED SWLED 13 moo\ SCWLED, Strobe, Ceiling, White SYSTEM SENSOR SCWLED SCWLED 1 H L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING SYSTEM SENSOR PC2WL PC2WL 4 E° He SK, EOL, 4.7K Ohms SILENT KNIGHT EOL-4.7 EOL-4.7 1 Circuit Calculations Panel: P1 Card: 00 Circuit:NAC1 Circuit Name: NAC1 Circuit Type: Notification Terminal Voltage: 20.4V:DC Amperage: 3.000OA Cable: 7611323, Wire/Cable/Fiber, 16 AWG, 2 Conductor Bare Copper, Twisted #16 Calculations based on Running Total Length. Design Criteria: Ambient temperature: 167°F Max. operating voltage drop: 18% Device Part No Appliance Desc Distance Current Voltage Voltage Drop HPF-PS10 Panel 20AV 001 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 22'-2'/2 18.000OmA 20.3238V (0.0762V) 002 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 8'-8'/4 18.0000mA 20.2948V (0.029V) 003 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 7'-1'/4 18.000OmA 20.2718V (0.0231V) 004 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 10'-3 18.0000mA 20.2394V (0.0324V) N:005 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 30CD 12'-91�2 90.000OmA 20.2001V (0.0393V) N:007 P2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL, 30CD 20'-01/z 74.000OmA 20.1494V (0.0507V) 008 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 28'-61/4 18.000OmA 20.0878V (0.0616V) N:009 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 30CD W-9 90.00OOmA 20.0738V (0.014V) 010 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 7'-11'�2 18.000OmA 20.0609V (0.0129V) 011 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 10'-234 18.000OmA 20.0453V (0.0156V) 012 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 10'-2 18.000OmA 20.0306V (0.0147V) 013 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 10'-034 18.000OmA 20.017V (0.0136V) N:014 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 30CD 5%61,'2 90.000OmA 20.0101V (0.007V) 015 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 6'-6 18.000OmA 20.0048V (0.0053V) 016 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 16'-434 18.000OmA 19.993V (0.0118V) N:017 PC2WL L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING, 30CD 10'-11)'2 90.000OmA 19.9866V (0.0064V) 018 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 9'-6 18.000OmA 19.9849V (0.0017V) N:019 SCWLED SCWLED, Strobe, Ceiling, White, 15CD 10'-10 18.000OmA 19.9839V (0.001V) EOL: EOL-4.7 SK, EOL, 4.7K Ohms 2'-10 z 0.000OmA 19.9839V (OV) 006 SWLED SWLED, Strobe, Wall, White, L-Series, 15CD 8'-9'/4 18.000OmA 20.1993V (0.0008V) 225'-3 z 686.000OmA Total Current: 686.000OmA (Total VDrop Percent:2.04%) Total Voltage Drop : 0.4161V Battery Calculations for Panel: P1 Part No:HPF-PS10 - HPF-PS10, Power Supply, Remote Charger, 10A, 120VAC, Red Enclosure Part No. Qty. Description Standby Total Standby Alarm Total Alarm Panel Equipment HPF-PS10 MB 1 HPF-PS10 MB, Main Board 156.000OmA 156.000OmA 185.000OmA 185.000OmA Total Panel Stby 156.000OmA Total Panel Alarm 185.000OmA Peripheral Devices P2WL 1 L-SERIES 2-WIRE, HORN STROBE, WHITE, WALL (Notification) 30CD 89dB 0.000OmA 0.000OmA 74.000OmA 74.000OmA SWLED 13 SWLED, Strobe, Wall, White, L-Series (Notification) 15CD 0.000OmA 0.000OmA 18.000OmA 234.0000mA SCWLED 1 SCWLED, Strobe, Ceiling, White (Notification) 15CD 0.000OmA 0.000OmA 18.000OmA 18.000OmA PC2WL 4 L-SERIES 2-WIRE, HORN STROBE, WHITE, CEILING (Notification) 30CD 89dB 0.0000mA 0.000OmA 90.000OmA 360.000OmA EOL-4.7 1 SK, EOL, 4.7K Ohms (Notification) 0.0000mA 0.000OmA 0.000OmA 0.000OmA Total Peripheral Stby 0.000OmA Total Periph Alarm 686.000OmA Total Standby Amps 156.000OmA Total Alarm Amps 871.0000mA Standby time: 24 Hrs 3.744Ah Alarm time: 5 Min 0.073Ah Battery requirement: 3.817Ah Compensation Factors - Standby:1.25 Alarm:1.25 Requirement with compensation: 4.771Ah SYSTEM OUTPUTS Notification o4:'_ o Co Qo a �o �°j C Caj o� a Uj zctr 'Q Co Qj 0 co Co A�' Q �� GD �Q ��o o� Cj o moo, o 0 /a O� a O� a \� �c� J �. v 'T . r .' v v � . J�D'/,RT �J� rII �J(D' .riT �JrII rU co � � m Mr SYSTEM INPUTS A B C D[El F G HI I I J FK L 1 Manual Fire Alarm Boxes 0 0 1 2 Smoke Detectors 00 0100 0 2 3 Waterflow 3 4 Sprinkler Control Valve lee 0010 46 4 5 Fire Alarm AC Power Failure 0 0, 00- 5 6 Fire Alarm System Low Battery 6 7 Open Circuit ® 7 8 Ground Fault ® 8 9 Notification Appliance Circuit Short 9 DEVICE MOUNTING HEIGHTS CEILING 24" MIN, ADA ROOM NFPA 72 SYNCHRONIZE MORE THAN TWO APPLIANCES IN ANY FIELD OF VIEW NFPA 72 FINISHED FLOOR CEILING MOUNTED AUDIBLE/VISUAL DEVICE AUDIO / VISUAL AND VISUAL -ONLY DEVICES 80" MIN. 96" MAX NFPA 72 IAMB C D E F G H I J K LI OPERATIONAL MATRIX CEILING MOUNTED SMOKE/HEAT DETECTOR 10' A.F.F. ANYTHING ABOVE 10' SHALL BE DERATED PER NFPA 72 48" MAX 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSTALLATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T-TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. FIRE SYSTEMS WEST WILL RELOCATE (1) EXISTING PULL STATION. 8. FIRE SYSTEMS WEST WILL RELOCATE (1) EXISTING HORN STROBE. 9. FIRE SYSTEMS WEST WILL RUN NEW FIRE ALARM CIRCUIT. 10. FIRE SYSTEMS WEST WILL INSTALL NEW FIRE ALARM NOTIFICATION DEVICES FOR NEW TENANT LAYOUT. WORK AREA (SUITE Al EI�Rey�Burro Mexican Mr D lug Restaurant Traditional American k k N •V i FA - - r -� 71 r 0 �3 . • �yZV VICINITY MAP NOT TO SCALE a A 14/2 FPLP CODE COMPLIANCE DESIGNER REVISIONS "Is B 16/2 FPLP 206 Frontage Rd. North #C JORDAN GARRISON NO. DESCRIPTION DATE BY CHK ��Qi W. Pacific WA 98047 JOB #: 817-1838 PULSE HEART E EXISTING LOCATION OCCUPANT TYPE: B CITY MUNICIPAL CODE 1 ISSUED FOR REVIEW 01/29/2026 JHG MWC ssu o ' D DEMO DEVICE FIRE SYSTEMS WEST, INC ' f:(253) 735-0113 DATE: 01/29/2026 CONTRACT NAME: CONTRACT WITH: N NEW DEVICE OCCUPANT LOAD: 25 2021 INTERNATIONAL BUILDING CODE •�'C PULSE HEART RANGE ELECTRIC 206 FRONTAGE ROAD NORTH #C ,� t:(253) 833-1248 R RELOCATE AREA: 2200 SF. 2021 INTERNATIONAL FIRE CODE PACIFIC, WASHINGTON 98047 • 902 E YELM AVE, SUITE A PO BOX 1506 STROBE COVERAGE AREA SHALL BE DEFINED AS SCALE: 1 /4"=1'-0" YELM, WA 98597 ENUMCLAW, WA 98022 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. CONSTRUCTION: V-B 2023 NATIONAL ELECTRICAL CODE 15 cd = 20'x2o' 30 cd = 20'x2o' 75 cd = 20'x2o' WA ECL# FIRESWI 055LW SHEET: FA01 ON -SITE CONTACT: DREW MASSEY/PHONE:253-294-3550/EMAIL:DMASSEY@RANGE-ELECTRIC.COM 30cd=30'x3o' 75cd=30'x3o' 95cd=30'x3o' 75cd=40'x40' 95cd=40'x4o' 110cd=40'x4o' SPRINKLERED: YES 2022 NATIONAL FIRE ALARM &SIGNALING COD9 X WA CL# FIRESWI 140B1 95 cd = 50'x50' 110 cd = 50'x50' 115 cd = 50'x50' TO EXISTING POWER SUPPLY FIRE ALARM NOTIFICATION DEVICE PLAN N SCALE: ,/a._,._o. TO EXISTING FACP PULL STATION RELOCATION SCALE: 1/4"=1'-0" G.ENERAL.NOTES /_ SCOPE -OF WORK- 1. SYSTEM WIRING NOTED ON THE DRAWINGS IS PER MANUFACTURE AND CODE REQUIREMENTS. ANY ALTERATION TO SYSTEM WIRING, WITHOUT APPROVAL, IS AT ELECTRICAL CONTRACTOR'S OWN RISK!! 2. SYSTEM WIRING SHOWN ON DRAWINGS IS DIAGRAMMATIC AND ONLY USED FOR REFERENCE PURPOSES. ACTUAL WIRE AND DEVICE INSTALLATION MAY VARY DUE TO OBSTRUCTIONS. 3. WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS LEADING TO FIRE PROTECTION EQUIPMENT. OTHER WIRE SHALL NOT BE PERMITTED IN THE SAME RACEWAY. 4. FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE LATEST U.L., N.E.C., N.F.P.A., W.A.C., AND OTHER STANDARDS AS APPLICABLE TO THE CITY STANDARDS. 5. WHEN NECESSARY, DUE TO CHANGING DESIGN REQUIREMENTS, FACTORY AVAILABILITY, ETC. FIRE SYSTEMS WEST RESERVES THE RIGHT TO SUBSTITUTE EQUIPMENT HEREIN MENTIONED OR SPECIFIED, WITH EQUIPMENT OF EQUAL OR BETTER QUALITY, FUNCTION AND DESIGN. 6. PARALLEL BRANCHING (T-TAPPING) OF WIRE TO ALL NOTIFICATION APPLIANCE CIRCUITS SHALL NOT BE PERMITTED. 7. FIRE SYSTEMS WEST WILL RELOCATE (1) EXISTING PULL STATION. 8. FIRE SYSTEMS WEST WILL RELOCATE (1) EXISTING HORN STROBE. 9. FIRE SYSTEMS WEST WILL RUN NEW FIRE ALARM CIRCUIT. 10. FIRE SYSTEMS WEST WILL INSTALL NEW FIRE ALARM NOTIFICATION DEVICES FOR NEW TENANT LAYOUT. JOB #: 817-1838 PULSE HEART A 14/2 FPLP B 16/2 FPLP E EXISTING LOCATION D DEMO DEVICE N NEW DEVICE R RELOCATE STROBE COVERAGE AREA SHALL BE DEFINED AS 10 FT. CLG. HT. 20 FT. CLG. HT. 30 FT. CLG. HT. 15 cd = 20'x2o' 30 cd = 20'x2o' 75 cd = 20'x2o' 30cd=30'x3o' 75cd=30'x3o' 95cd=30'x3o' 75cd=40'x4o' 95cd=40'x4o' 110cd=40'x4o' 95 cd = 50'x50' 110 cd = 50'x50' 115 cd = 50'x50' CODE COMPLIANCE DESIGNER REVISIONS "is 206 Frontage Rd. North #C st �s Pacific WA 98047 �� ' •�''C ' o f:(253) 735-0113 t:(253) 833-1248 • WA ECL# FIRESWI 055LW WA CL# FIRESWI 140B1 OCCUPANT TYPE: B CITY MUNICIPAL CODE OCCUPANT LOAD: 25 2021 INTERNATIONAL BUILDING CODE AREA: 2200 SF. 2021 INTERNATIONAL FIRE CODE CONSTRUCTION: V-B 2023 NATIONAL ELECTRICAL CODE SPRINKLERED: YES 2022 NATIONAL FIRE ALARM &SIGNALING CODE JORDAN GARRISON FIRE SYSTEMS WEST, INC 206 FRONTAGE ROAD NORTH #C PACIFIC, WASHINGTON 98047 X NO. DESCRIPTION DATE BY CHK 1 ISSUED -FOR REVIEW 01/29/2026 JHG MWC DATE: 01/29/2026 CONTRACT NAME: PULSE HEART 902 E YELM AVE, SUITE A YELM, WA 98597 CONTRACT WITH: RANGE ELECTRIC PO BOX 1506 ENUMCLAW, WA 98022 SCALE: 1 /4"=1'-0" SHEET: FA02 ON -SITE CONTACT: DREW MASSEY/PHONE:253-294-3550/EMAIL:DMASSEY@RANGE-ELECTRIC.COM