HomeMy WebLinkAbout2090 OlympiaWSU Code Compliance Calculator
Project Information Messages / Comments *RESULT=PASS
Century Communities
Olympia Note: Review required for custom entries: - Doors- Flat/Vaulted Ceilings
Plan 2090 UA Reduction = 39.65, Proposed UA is better than baseline by 16%
Contact Information UA reduction meets percent target of selected Option 1.2
Jacob Hooper, RESNET Rater/QAD Window area is 9% of floor area
ICS-Inspectors -
jacobh@ics-inspectors.com 360.713.1896 Whole House Mechanical Ventilation Airflow Rate: 97.5 CFM with Run Time Percent of 100%, Unbalanced, Not Distributed
Maximum allowable total measured duct leakage: 167 CFM25
ANALYSIS SET UP
What code compliance pathway are you using?
Project Building Type?
Occupancy Type?
Code Version?
Classification:Medium Dwelling Unit -- 2090 sq. ft.
Baseline Description: Code Baseline - Maximum baseline window area is 15% of floor area.
About Your Selection:No exempt window or door areas
-
RESULTS - Comparison of Baseline and Proposed Design **
Component Performance, R occupancies
U *Area UA Area UA
Doors U =0.300 38 11.3 38 6.4
Overhead Glazing U =0.500 0 0.0 0 0.0
Vertical Glazing U =0.300 185 55.5 185 46.3
Flat/Vaulted Ceilings U =0.024 1,306 31.3 1,306 24.2
Wall (above grade) U =0.056 2,101 117.7 2,101 105.4
Floors over Crawlspace U =0.029 1,306 37.9 1,306 31.8
Slab on Grade F =0.540 0 0.0 0 0.0
Below Grade Wall U =N/A 0 0 0.0
Below Grade Slab F =N/A 0 0 0.0
* Values from Table R402.1.2 (Oct 2023)
Baseline UA Total 253.7 Proposed UA Total 214.1
Required Credits 8.0 Proposed Credits 8.0 from Tables 406.2 and 406.3
UA Percent Reduction 16%
UA Reduction 39.6
** Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ.
Total Credits
(406.2 & 406.3)
8.0
* Results assume your inputs are complete and correct. Results do not constitute an approval. Analysis should be reviewed by your AHJ.
Air source ducted Heat Pump w/ Min HSPF2 of 10 (HSPF of 11). If htg
design temp is 23F or below,a cold climate variable capacity heat pump
is required.
Ducts/distribution system in conditioned space per R403.3.2 Electric
resistance, hydronic, ductless and gas fired systems < 80% AFUE
systems not permitted
1.0
0.5
Efficient Building Envelope
3.1 -3.10
1
Option 3.6
3.11
4
High Efficiency HVAC: Smart Thermostat NA
High Efficiency HVAC Distribution System
0.250
0.019
0.050
0.024
Proposed Design
Total UA Alternative, Whole Building Trade Off Analysis
U
Baseline Design
New Construction
R3 Single family dwellings and townhouses
WSEC 2021
0.170
Option 4.1
5.0
Full Description
For heating system using a heat pump that meets federal standards for the equipment
listed in Table C403.3.2(2) or Table C403.3.2(9) OR Air to Water heat pump units that
are configured to provide both heating and cooling and are rated in accordance with
AHRI 550/590
High Efficiency HVAC
System No.
4
1.0
Brief Description of Selected Options*Category
Select System Type
Energy Credits
Fuel Normalization
Credits (406.2)
Table R406.2 Energy Equalization Credits
3.0Variable Refrigerant Heat Pump or Air-to-
Water Heat Pump
Table R406.3 Energy Credits
Energy Credits (406.3)
Select Options
Option 1.2
Perscriptive compliance per Table 402.1.3 / U-0.25 vertical fenestration /
R-38 floors or R-10 perimeter & fully insulated slab. Or 15% reduction in
UA per section R402.1.5
Option No.
2 Air Leakage Control and Efficient Ventilation
2090 Template.xlsm, Version:5/28/2025 1:26:11 PM 7/24/2025 1
WSU Code Compliance Calculator
Renewable Electric Energy kWh
Energy Credits
*Refer to WSEC 2021 Table R406.3 for complete option descriptions and requirements
0.0
Electric heat pump water heater meeting NEEA Tier 3.
Compact Hot Water Distribution System Max volume between heat
source and fixture is 16 Oz per section R403.5.2, on demand circ. Pump
may be required.
0.0
5.0
7 Appliance Package
https://sbcc.wa.gov/state-codes-regulations-guidelines/state-building-code/energy-code
6
2.0
Efficient Water Heating: Drain Heat Recovery
Efficient Water Heating
Efficient Water Heating: Compact Hot Water Distribution
5.1
5.3-5.8
5.2
Option 5.6
Option 5.2 0.5
0.0
2090 Template.xlsm, Version:5/28/2025 1:26:11 PM 7/24/2025 2
WSU Code Compliance Calculator
THERMAL ENVELOPE DETAILS - Proposed Design
Conditioned Floor Area, Proposed Design 2,090 sq. ft
Classification Medium Dwelling Unit
Exterior Doors
Plan Component Door
ID Description Ref. U Qt. Feet Inch Feet Inch Area UA
Entry Solid Core Door Custom 0.17 1 3 6 8 20 3.4 Refer to WSEC R402.1.5 U-factor Reference and Calculations
Garage Solid Core Door Custom 0.17 1 2 8 6 8 18 3.0 Refer to WSEC R402.1.5 U-factor Reference and Calculations
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
0 0.0
Sum of Area and UA 38 6.4 0 2
Exterior Doors Area Weighted U 0.170
Overhead Glazing
Plan Component Glazing
ID Description U Feet Inch Feet Inch
-
-
-
-
-
0.0 0 0 0
Overhead Glazing Area Weighted U
Vertical Glazing Schedule Rows to Show 16
Plan Component Glazing
ID Description U Feet Inch Feet Inch
1 SH U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 1 2 4 8.0 2.00
2 SLDR U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 4 4 4 64.0 16.00
3 SLDR U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 1 6 5 30.0 7.50
4 SGD U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 1 6 6 10 41.0 10.25
5 SH U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 1 2 3 6.0 1.50
6 SLDR U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 1 6 4 24.0 6.00
7 PIC U=0.25 (2021 1.2; 2018 1.4)Table 406.2 / 406.3 0.25 1 3 4 12.0 3.00
8 - -
9 - -
10 - -
11 - -
12 - -
13 - -
14 - -
15 - -
16 - -
Sum of Area and UA 185.0 46.3 0
Vertical Glazing Area Weighted U 0.250
Vertical Glazing and Doors Area Weighted U 0.236
Flat/Vaulted Ceilings
Plan Component Attic
ID Description U
Ceiling 2x6 24"oc R60 cavity + R23 Eaves Custom 0.019 1,306 24.2 Refer to WSEC R402.1.5 U-factor Reference and Calculations
1,306 24.2 1
Area Weighted U-Value 0.019
Walls (Above Grade)
Plan Component Wall
ID Description Ref. U UA
Width
Ref.
Ref.
Height
Notes
Height
Area
Width
Qt.
Sum of Area and UA
Qt. UAArea
HeightWidth
Sum of Area and UA
Ref.
Net Area
Area
UA
UA
2090 Template.xlsm, Version:5/28/2025 1:26:11 PM 7/24/2025 3
WSU Code Compliance Calculator
Ambient R23 cavity+R0 foam INT 2X6W Lap App A 0.049 1,823 89
Garage R23 cavity+R0 foam INT 2X6W Lap App A 0.049 256 13
STEM Int Concrete Floors, R-5 Ext., 6"wall 10-5B 0.161 22 4
2,101 105 0
Gross Wall Area 2,324 ft2
Area Weighted U-Value 0.050
Sum of Net Area and UA
2090 Template.xlsm, Version:5/28/2025 1:26:11 PM 7/24/2025 4
WSU Code Compliance Calculator
Floor (over crawl or exterior)
Plan Component Floor UA
ID Description Ref. U
Main R38 vented Post/Beam (2021 1.2, 1.3; 2018 1.3-1.5)10-3 0.024 835 20
Garage R38 vented Joist (2021 1.2, 1,3; 2018 1.3-1.5)10-3 0.025 455 11
Ambient R38 vented Joist (2021 1.2, 1,3; 2018 1.3-1.5)10-3 0.03 16 0
1,306 32 0
Area Weighted U-Value 0.024
Slab on Grade (less than 2 feet below grade)
Plan Component Slab
ID Description Ref. F FP
0 0 0
Area Weighted U-Value
Below Grade Walls and Slabs
Plan Component Slab Wall Wall Wall Slab
ID Description Depth Ref. U Area UA UA
Sum of Area, Length and UA 0 0 0 0 0
Weighted U- and F-values
Links to Download Forms, Checklists and Other Resources
Compliance Certificate Instructions
Insulation Certificate for Residential New Construction
Duct Testing Affadavits
Existing Construction
New Construction
Prescriptive Checklist for 2018 WSEC
Alterations (Remodel) Worksheet
EER SEER2 COP HSPF2 Converter https://www.adicotengineering.com/eer-seer2-cop-hspf2-kwton-converter
Ventilation Requirements
Conditioned Floor Area 2,090 sq. ft.
Number of Bedrooms 4
Run-Time Percent in Each 4-Hour Segment 100%
Is the system Balanced?
Is the system Distributed?
Ventilation Code Section IRC, Chapter 15
Whole House Mechanical Ventilation Airflow Rate 98 CFM
HVAC Thermal Distribution System Download RS-33 (2018)
Is this a hydronic heating system?
Location of Ducts
Location of Air Handler
Is Duct Testing Required? Yes
Maximum Duct Leakage:
Maximum total measured duct leakage per square foot 0.08 CFM25 per sq. ft.
Maximum allowable total measured duct leakage 167 CFM25
A maximum of 10 feet of return ducts and 5 feet of supply ducts are allowed to be located outside of the building thermal envelope, if insulated and sealed per R403.3.7.
Heating System Sizing - Proposed Design Try Out BetterBuiltNW's HVAC Sizing Tool:
Nearest Weather Station
Indoor Design Temperature 70 F
Outdoor Design Temperature 17 F
Design Temperature Difference (∆T)53 F
Conditioned Floor Area, Proposed Design 2,090 ft2
Conditioned Volume 18,759 ft3 Average ceiling height =9 ft. Volume = 18759 ft3 0.00
Leave blank to use default of 8.5 ft. ceiling height
Average ceiling height 9.0 ft
http://www.energy.wsu.edu/Documents/Duct%20Testing%20Standards%20_2018%20WSEC.pdf
Conditioned Space
https://betterbuiltnw.com/resources/hvac-sizing-tool
Link
Prescriptive Checklist
Affidavit, Existing
Affidavit, New
Worksheet
No
Sum of Perimeter and FP
Slab Slab
Perim
Conditioned Space
Area
Insulation Certificate
Sum of Area and UA
Not Distributed
Unbalanced
Compliance Certificate
Slab
Perim
F
Olympia, AP.
2090 Template.xlsm, Version:5/28/2025 1:26:11 PM 7/24/2025 5
WSU Code Compliance Calculator
HVAC System Type
Location of HVAC Distribution System Conditioned Space
Sum of UA 214
Envelope Heat Load 11,345 Btu / Hour
Sum of UA X ∆T
Air Leakage Heat Load 10,738 Btu / Hour
((Volume X 0.6) X ∆T) X .018))
Building Design Heat Load 22,083 Btu / Hour
Air Leakage + Envelope Heat Loss
Building and Duct Heat Load 22,083 Btu / Hour
For ducts located in unconditioned space: Sum of Building Heat Loss X 1.1
For ducts located in conditioned space or ductless: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 27,604 Btu / Hour
Building and Duct Heat Loss X 1.25 for heat pumps 8.1 kW
Building and Duct Heat Loss X 1.40 for all other systems
Heat Pump