HomeMy WebLinkAboutPlan 012090 GR Elev B 2021 code Yelm 07-17-2025WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. DUE TO POTENTIAL ALTERING DURING THE PRINTING PROCESS, DO NOT SCALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO PROCEEDING WITH CONSTRUCTION. ANY ALTERATION, REVISION OR SITE CONDITION WARRANTING GHANGE TO THE PLANS MUST BE VERIFIED WITH MWJ HOMES AND THE PROJEGT STRUGTURAL ENGINEER PRIOR TO GONSTRUGTION. ANY GONSTRUGTION TRADE WORKING ON THE PROJECT MUST HAVE KNOWLEDGE OF THE LOCAL AND NATIONAL CODES. MWJ HOMES IS NOT RESPONSIBLE FOR THE KNOWLEDGE OF TRADESPEOPLE THAT ARE NOT EMPLOYED BY MWJ HOMES. ANY ALTERATION TO THE PROJECT MADE WITHOUT PRIOR APPROVAL BY MWJ HOMES AND/OR THE PROJECT STRUCTURAL ENGINEER CAN/MAY/WILL RESULT IN PROJECT DELAYS AND THE GONTRAGTOR SHALL AGGEPT FULL RESPONSIBILITY FOR THE GOST AND TIME REQUIRED TO REGTIFY D R CTOR Al - FRONT/REAR ELEVATION IIAII E31 - FRONT/REAR ELEVATION 11511 GI - FRONT/REAR ELEVATION " "11 A2 - SIDE ELEVATIONS ELEVATION ''All E32 - SIDE ELEVATIONS ELEVATION I'B'I G2 - SIDE ELEVATIONS ELEVATION A5 - FOUNDATION PLAN A4 - MAIN FLOOR PLAN A5 - UPPER FLOOR PLAN - ROOF FLAN El EVATION Al - E I LD I NG SECT I ON-M I NOTES E - ELECTRICAL PLAN EN I -EN5 - WSEG NOTES aOL';)E I NP® MAT I ON CONSTRUCTION TYPE: 55 OCCUPANCY: R5, U (garage) 2021 INTERNATIONAL RESIDENTIAL CODE FOR ONE AND TWO FAMILY DWELLINGS 2021 INTERNATIONAL FIRE CODE 2021 UNIFORM PLUMBING CODE 2021 WASHINGTON STATE ENERGY CODE 2021 INTERNATIONAL MECHANICAL CODE CONSUL-TANTS ,ARCH 1 TEGT MWJ HOMES I ci515 NORTH CREEK PARKWAY SUITE 514 BOTHELL, WA -518011 PHONE: (425) 65a-4854 STRUCTURAL ENG 1 NEER RB ENGINEERS 1512 2nd STREET KIRKLAND, WA cib055 PHONE: (425) 522-5009 NOTES: I. ALL WOOD EXPOSED TO WEATHER SHALL BE PRESSURE TREATED, PAINTED OR CEDAR. 2. CAULK AND SEAL ALL WINDOW/DOOR AND EXTERIOR ENVELOPE PENETRATIONS. B. GLAZING PER STATE ENERGY CODE. 4. PROTECTION FROM DECAY 15 REOU I RED FOR ALL WOOD SIDING AND WALL FRAMING LESS THAN 2" ABOVE GONGRETE STEPS, PORGH SLABS, PATIO SLABS, AND SIMILAR HORIZONTAL SURFACES EXPOSED TO THE WEATHER S. REFER TO ALL ELEVATIONS FOR TYPICAL NOTES. 6. S.G. = SAFETY GLASS FLASHING NOTE APPROVED CORROSION-RES 1 STANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN SUCH A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF WATER INTO THE BUILDING STRUCTURAL FRAMING COMPONENTS THE FLASHING SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION RESISTANT FLASHING SHALL BE INSTALLED AT THE FOLLOWING LOCATIONS: 1. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION W 1 TH FRAME OR STUCCO WALLS S. UNDER AND AT THE ENDS OF MASONRY, WOOD, OR METAL GOP I NGS AND SILLS 4. CONTI NUOUSLI' ABOVE ALL PROJECTING WOOD TRIM S. WHERE EXTERIOR PORCHES, DECKS, OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD FRAME CONSTRUCTION 6. AT WALL AND ROOF INTERSECTIONS -7. AT BUILT IN GUTTERS ADDRESS NOTE: ADDRESS NUMBERS SHALL BE A MINIMUM 4" HIGH WITH A MINIMUM STROKE WIDTH OF 1/2" AND TO BE ON A CONTRASTING BACKGROUND PER I RG S 1 ci.1 ASPHALT COMP. SHINGLES METAL FASC I A GUTTER BOARD AND BATTEN S 1 D I NG- I X5 BATTENS (g) 12" O.G. W/ HARD I E-PANEL BEHIND L\21h.- ��� \1 12 01 r-FkONT r=L-r=\/AT 1 ON ''A'-' SEE C7ENERAL NOTES SCALE: 1/4" = 1'-0" fR,,r=AI\ r=Lr ll ATI OIL, 11A11 SEE GENE'_RAL NOTE=5 SCALE: 1/4" = 1'-0" HEIGHT OF STRUCTURE 5 /4 x 10 BARGE - BOARD W/ I XS AT GABLE ENDS UPPER FLOOR P.L. 5 /4 X 4 WINDOW/ DOOR TRIM AT ALL ELEVATIONS FIN. FLR. UPPER MAIN FLOOR P.L. HORIZONTAL LAP SIDING I X 4 CORNER 1 PIN. PLR. MAIN ER FLOOR P.L. FLR. UPPER N FLOOR P.L. FLR. MA I SQUAR'E: �OOTAGE:S UPPER 1255 TOTAL_ 20cf O C�ARAC�E: 4-74 G0NE=51"E=D 8a PORGY PST I O 100 ADDRESS NOTE: ADDRESS NUMBERS SHALL BE A MINIMUM 4" HIGH WITH A MINIMUM STROKE WIDTH OF 1/2" AND TO BE ON A CONTRASTING BACKGROUND PER I RC 51q.1 125-71 REG 15TERED V'�� ARC -HI TEGT MIGH L YNE JOHNSON STATE OF WASHINGTONop �z w N Q z<wQQ 0 wp� zzo40Q<z0 wI 00.0.0.z�wF O z0�n 0 I Q� �OT11 MU-� pd 000z 7w0--@ Jz�m�i0w,n Q a i= � O a a� o UoMo Z M � ll') N � �— co .7 � w 0 2 7 • E: L_ E: V.� T I ON ,� o l�n o - V V date : 0-7-09-25 permit: revisions: drawn by .by CWL checked : MWJ I WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. DUE TO POTENTIAL ALTERING DURING THE PRINTING PROCE!!, DO NOT !GALE DRAW 1 NGl. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO PROCEEDING WITH CONlTRUCTI ON. ANY ALTERATION, REVISION OR SITE CONDITION WARRANTING GHANGE TO THE PLANS MUST BE VERIFIED W 1 TH MWJ HOMES AND THE PROJEGT STRUGTURAL ENGINEER PRIOR TO GONlTRUGTION. ANY GONSTRUGTION TRADE WORKING ON THE PROJECT MUST HAVE KNOWLEDGE OF THE LOCAL AND NATIONAL CODES. MWJ HOMES IS NOT RESPONSIBLE FOR THE KNOWLEDGE OF TRADESPEOPLE THAT ARE NOT EMPLOYED BY MWJ HOMES. ANY ALTERATION TO THE PROJECT MADE WITHOUT PRIOR APPROVAL BY MWJ HOMES AND/OR THE PROJECT STRUCTURAL ENGINEER CAN/MAY/WILL RESULT IN PROJECT DELAYS AND THE GONTRAGTOR SHALL AGGEPT FULL RESPONSIBILITY FOR THE G05T AND TIME REOUIRED TO REGTIFY NOTES: I. ALL WOOD EXPOSED TO WEATHER SHALL BE PRESSURE TREATED, PAINTED OR CEDAR. 2. CAULK AND SEAL ALL WINDOW/DOOR AND EXTERIOR ENVELOPE PENETRATIONS. 5. GLAZING PER STATE ENERGY CODE. 4. PROTECTION FROM DECAY 15 REQU I RED FOR ALL WOOD S 1 D I NCB AND WALL FRAMING LESS THAN 2" ABOVE GONGRETE STEPS, PORCH SLABS, PATIO SLABS, AND SIMILAR HORIZONTAL SURFAGES EXPOSED TO THE WEATHER 5. REFER TO ALL ELEVATIONS FOR TYPICAL NOTES. 6. S.G. = SAFETY GLASS FLASHING:, NOTE APPROVED GORROS I ON -RESISTANT FLASHING SHALL BE APPLIED SHINGLE FASHION IN SUCH A MANNER TO PREVENT ENTRY OF WATER INTO THE WALL GAV I TY OR PENETRATION OF WATER INTO THE BU I LLD I NG 5TRUGTURAL FRAMING COMPONENTS THE FLASHING SHALL EXTEND TO THE SURFAGE OF THE EXTERIOR WALL FINISH. APPROVED CORROSION RESISTANT FLASHING SHALL BE INSTALLED AT THE FOLLOW 1 NG LOGATI ONS: I. EXTERIOR WINDOW AND DOOR OPENINGS. FLASHING AT EXTERIOR WINDOW AND DOOR OPENINGS SHALL EXTEND TO THE SURFACE OF THE EXTERIOR WALL FINISH OR TO THE WATER RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE 2. AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY GONSTRUGTI ON WITH FRAME OR STUCCO WALLS 5. UNDER AND AT THE ENDS OF MASONRY, WOOD, OR METAL GOP I NG! AND SILLS 4. GONTI NUOUSLY ABOVE ALL PROJEGTI NG WOOD TRIM 5. WHERE EXTERIOR PORCHES, DECKS, OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF WOOD FRAME GONSTRUGTI ON 6. AT WALL AND ROOF INTERSECTIONS -7. AT BUILT IN GUTTERS SEE GENERAL NOTES SCALE: I/4" = I'-O" 4x OUTLOOKERS BHT OF STRUCTURE zGE I XS NDS 'ER FLOOR P.L. -I AT IONS FLR. UPPER IN FLOOR P.L. �L LAP SIDING zNER d) FLR. MA I N UPPER FLOOR P.L. FIN. FLR MAIN FL F I N. FLR. �� �� OPT. GVRD. PATIO f;kr=AR-, r=L-r l/ AT 1 O N IIE511 SEE GENERAL NOTES SCALE: 1/4" = 1'-0" UPPER FOR P.L. MA I I �� I REG 15TERED ARC -HI TEGT MIGH L YNE JOHNSON STATE OF WASHINGTONop �z w Q z'(jwzQQ 0 wQ� •0.Q- z0QWOQ�zQ O OIL z0�n Qd �OOz Jz�t��i0u�,n N f�� < # Q 4ztH Q a i= � O a a� o UoMo Z M � u'� N `d � W 0 2 7 • E L. EV.�T I Ol�l � 0 0 date : 0-7-09-25 permit: revisions: drawn by .by CWL checked : MWJ I NRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SGALED DIMENSIONS. DUE TO POTENTIAL ALTERING DURING THE PRINTING PROCESS, DO NOT SGALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND GONI7I TI ONS PRIOR TO PROGEEIDING KITH GONSTRUGTION. ANY ALTERATION, REVISION OR SITE CONDITION NARRANTING CHANGE TO THE PLANS MUST BE VERIFIED NI TH MNJ HOMES AND THE PROJECT STRUGTURAL ENGINEER PRIOR TO CONSTRUGTION. ANY GONSTRUGTION TRADE NORKING ON THE PROJECT MUST HAVE <NONLEDGE OF THE LOCAL AND NATIONAL GODES. MNJ HOMES IS NOT RESPONSIBLE FOR THE KNOWLEDGE OF TRADESPEOPLE THAT ARE NOT EMPLOYED BY MNJ HOMES. ANY ALTERATION TO THE PROJEGT MADE NITHOUT PRIOR APPROVAL BY MNJ HOMES AND/OR THE PROJECT STRUGTURAL ENGINEER GAN/MAY/NI LL RESULT IN PROJECT DELAYS AND THE GONTRAGTOR SHALL ACGEPT FULL RESPONSIBILITY FOR THE GOST AND TIME REOU I RED TO REGTI FY i d UPPER FL( FLC MAIN FLC 14. F1 i d UPPER FL( I FLr- MAIN FLC FIN. F1 FkI C-7�4T F.Lr=\/AT 1 ON I I E3 I I SEE CGENER?.L NOTES SCALE: 1/4" = I'-O" L.r=r—m7 111511 SEE GENERAL NOTES SCALE: 1/4" = 1'-0" �� REGISTERED ARGiiITEGT Mlc:,H L YNE JOHNSON STATE OF WASFFINGTON 00 N Q Q zz�� Oz0U1�-l��Q� �i�u�i� N Po Q � lu # <Q�o a zz lu Y(wzo �a a a � o N � cn N � N UoM ma m ; O Z M � � n �a) `° 3 °� in .N7 cn w Q 2 • ELE�IAT 101�1 � O 0 date: o7-oq-z5 permit: revisions: drawn by: G1N1_ che�i«d by: WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SGALED DIMENSIONS. DUE TO POTENTIAL ALTERING DURING THE PRINTING PROCESS, DO NOT SGALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND GONI7I TI ONS PRIOR TO PROGEEID I NG WITH GONSTRUGTI ON. ANY ALTERATION, REVISION OR SITE CONDITION WARRANTING CHANGE TO THE PLANS MUST BE VERIFIED WITH MWJ HOMES AND THE PROJECT STRUGTURAL ENGINEER PRIOR TO CONSTRUGTION. ANY GONSTRUGTION TRADE WORKING ON THE PROJECT MUST HAVE <NOWLEDGE OF THE LOCAL AND NATIONAL GODES. MWJ HOMES IS NOT RESPONSIBLE FOR THE KNOWLEDGE OF TRADESPEOPLE THAT ARE NOT EMPLOYED BY MWJ HOMES. ANY ALTERATION TO THE PROJEGT MADE WITHOUT PRIOR APPROVAL BY MWJ HOMES AND/OR THE PROJECT STRUGTURAL ENGINEER GAN/MAY/WILL RESULT IN PROJECT DELAYS AND THE GONTRAGTOR SHALL ACGEPT FULL RESPONSIBILITY FOR THE GOST AND TIME REOU I RED TO REGTI FY A GRANLSFACGE VENT C ALGULATI ON qOq SOUARE FEET = 5.05 E300 .5-1 VENTS R) EOU I RFD \I FOUNDATION VENTS 16"x8" SCREENED 6 REOUIRED F -17 � �I 6 MIL. BLACK VAPOR I °sBu -IN BARRIER TO TOP OF PTG. dI W/ I2" LAP ® ALL 5EAM5 I D I, I �II 12" MINIMUM UNMUM RLBEAMS N I I II � �II I IL = JI II I IS"x24" CRWL. L LJ _ SPACE AGGE55 - INS W5 I INK BV. CC�CC — — — W.G. G REF. i 01 — — — BV AB\/. T- — 3" STEEL IABV./ BOLLARD J AB\/. \ I II I II I I� 4" CONCRETE SLAB SLOPE _ E5 TO OVERHEAD DOOR GRANULAR PILL UNDER GARAGE SLAB N N I 4" CONCRETE SLAB SLOPE AWAY FROM THE HOUSE 1/4" PER FOOT MINIMUM A A-y TOUN��71Oil f=L.ANN SEE CGENER?.L NOTES SCALE: 1/4" = I'-O" i-EG I STEREO ARCHITECT LSBTA�TFOF� ,H YNE JOHN50N WASFFINGTON 0 a a a o (D cn N -C N U0Ma 4 co O 3 Z U-) un a) ° 3 L °'inCN W z Q i • O 0 date: o7-oq-z5 permit: revisions: drawn by GwL GheG�ced by : MWJ SHFEE E=—T N zz Q Q ZQlu jWQQ R 0 � zoo N Q � lJCJZ zz ul Q NRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SGALED DIMENSIONS. DUE TO POTENTIAL ALTERING DURING THE PRINTING PROCESS, DO NOT SGALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND GONI7I TI ONS PRIOR TO PROGEEIDING KITH GONSTRUGTION. ANY ALTERATION, REVISION OR SITE CONDITION NARRANTING CHANGE TO THE PLANS MUST BE VERIFIED NI TH MNJ HOMES AND THE PROJECT STRUGTURAL ENGINEER PRIOR TO CONSTRUGTION. ANY GONSTRUGTION TRADE NORKING ON THE PROJECT MUST HAVE IGNONLEDGE OF THE LOCAL AND NATIONAL GODES. MNJ HOMES IS NOT RESPONSIBLE FOR THE KNOWLEDGE OF TRADESPEOPLE THAT ARE NOT EMPLOYED BY MNJ HOMES. ANY ALTERATION TO THE PROJEGT MADE NITHOUT PRIOR APPROVAL BY MNJ HOMES AND/OR THE PROJECT STRUGTURAL ENGINEER GAN/MAY/NI LL RESULT IN PROJECT DELAYS AND THE CONTRAGTOR SHALL ACGEPT FULL RESPONSIBILITY FOR THE GOST AND TIME REOU I RED TO REGTI FY NOTES: ALL EXTERIOR HEADERS MUST BE INSULATED KITH R-10 INSULATION PER NSEG FOR NINDONS KITH OPERABLE OPENINGS MORE THAN -72" ABOVE THE FINISHED GRADE OR SURFACE C BELON, THE LONEST PART OF THE CLEAR OPENING 1 SHALL BE 24" MINIMUM ABOVE THE FLOOR. EXCEPTIONS: - FULLY OPEN NINI70NS NHERE A 4" SPHERE MAY NOT PASS THROUGH OR NHERE FALL PROTECTION DEVICES ARE PROVIDED PER ASTM F 20ci0 OR R612.3 TUB/SHOVER UNITS SHALL HAVE FIRE BLOCKING BETNEEN NALL STUDS AND NATERPROOF SURROUNDS TO +-72" FROM DRAIN. GLAZING, INCLUDING NINDONS WITHIN +72" OF DRAIN, SHALL BE SAFTEY GLASS. SHOVER FLON IS LIMITED TO 2.5 GAL/MIN. EXHAUST FANS LARGER THAN 50GFM MAY BE CONNECTED TO 4" SMOOTH HALL VENT PIPE IF RUNS DO NOT EXCEED 20' IN LENGTH. THE MINIMUM SIZE OF FLEX DUCT IS 5" DIAMETER KITH A MAXIMUM RUN OF 15' COMBUSTION AIR REQUIRED FOR ALL FUEL BURNING APPL I ANGE5 EXTERIOR DOORS SHALL BE PROVIDED KITH LANDINGS OR FLOORS NOT MORE THAN "7-5/4" BELON THE TOP OF THE THRESHOLD PER I RC R311.3 PROVIDE A MOISTURE EXHAUST DUGT FOR THE CLOTHES DRYER TO OUTSIDE AIR. THE DUCT SHALL BE MINIMUM 4" INCH IN DIAMETER OF METAL OR APPROVED MATERIAL KITH SMOOTH SURFACE. THE LENGTH SHALL NOT EXCEED 35 FEET (INCLUDING TRANSITION DUCTS) IF FITTINGS ARE USED, THE MAXIMUM LENGTH SHALL BE REDUCED TO BE PER DRYER OR THE DRYER EXHAUST POKER VENTILATOR'S MFG'S INSTALLATION PER IMG 504.5 ENVIRONMENTAL AIR DUCT EXHAUST SHALL TERMINATE NOT LESS THAN 5 FEET FROM A PROPERTY LINE AND 5 FEET FROM OPENINGS INTO A BUILDING PER IMG 501.5.1 THE MIXING VALVE IN A SHOVER (INCLUDING OVER A TUB) SHALL BE PRESSURE BALANCING SET AT 120F. THE HATER HEATER THERMOSTAT CANNOT BE USED TO MEET THESE PROVISIONS PER UPC 405.3 AND 40q.4 GOMBUSTION AIR TO BE PROVIDED TO FURNACE CLOSET VIA FRESH AIR FROM OUTSIDE. MEGH CONTRACTOR TO FIELD VERIFY EXPANSION TANK, PRESSURE RELIEF VALVE, AND SHUT OFF VALVE TO BE INSTALLED FOR THE HATER HEATER PER UPC, 605.3 BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUCTS OR PLENUMS. INSTALLATION OF DUCTS SHALL NOT DISPLACE REQUIRED ENVELOPE INSULATION PER NSEG R403.3.5 DUCTS NHIGH PENETRATE THE HALL OR FLOOR BETNEEN THE HALL OR FLOOR BETNEEN THE DNELLING AND GARAGE SHALL BE GONSTRUGTED OF A MINIMUM NO. 26 GAGE SHEET STEEL OR APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE PER I RG R302.5.2. LEGEND: O SMOKE DETECTOR IIOV INTERCONNECTED N/ BATTERY BACK-UP. PER I RG 514 OCARBON MONOXIDE DETECTOR PER IRG 315 HEAT DETECTOR ® GARAGE PER NA STATE AMENDMENT GARAGE NOTES: I. GARAGE/LIVING SEPARATION, USE 5/5" TYPE 'X' GNB AT CEILING/MALL. NRAP POSTS AND BEAMS. 2. INSULATE ALL HARM HALLS AND CEILING. 3. DOOR BETWEEN GARAGE AND RESIDENCE SHALL BE 1-5/5" MINIMUM THICK SOLID WOOD OR STEEL WITH SOLID OR HONEYCOMB GORE OR 20 MINUTE FIRE RATED EQUIPPED WITH A SELF GLOSING DEVICE. 4. DUCTS IN GARAGE AND DUCTS PENETRATING THE HALLS OR GE I L I NGS SEPERATI NG THE RESIDENCE FROM THE GARAGE SHALL BE NO. 26 GAGE SHEET STEEL AND HAVE NO OPENINGS INTO THE GARAGE 21f'-0" 16'-62 - - - - - - - - IJ �I I I I I I I PATIO ;PT. c vlzn 6050 x SLDR. 606 I O S I D I NCB CLASS OOR I I I �N T �r � DINING ROOM I. 01�u FLGREAT II I I o vQ 4� Op z II <>°_ o b IS"x24" CRNL. Li SPACE ACCESS INS NS K I TGHi=N I cV � 2668 6 2468 QS P N17ER 500 CFM p O OPT. J -- FAN® VTO �OW� REFCG. -- N N L — PANTRY STEP LOC. 00 �✓" STEEL HEAT PUMP BOLLARD VT IIOV S.D. UP TO 30" \ - MINIMUM d Q J HEAT DETECTOR <2 TO BE INTERCONNECTED TO THE ALARM IN 2T" THE HALLNAY THAT m K HILL PROVIDE UP 15 I OCCUPANT NOTIFICATION RISERS GARAGE LZ91 O.H. DOOR I _ I I _OF _ _ _LINE _ — — — — IN UPRIGHT POSITION I I I I COVERED I I I I I I PORCH I I I I I 16070 O.H. GARAGE DOOR 2 40 RIG. Cs o.) 2'-I I " 2'-S 1 1"-10 1 I11 2'-62 2 S -I I 2 2 16'-S" /I I A A-y 'I�AON r-L-OOf;k i=L.AN SEE CGENERAL NOTES SCALE: 1/4" = I'-O" ^ 128-71 I\\/> REGISTERED ARCHITECT �SBTA�TFOF� GH YNE JOHN50N WASFFINGTON 0 a a a o (D cn N _ N UoM0 mm 0 3 z to °) Ln a) `° 3 L o' in .N7 cn w z Q 2 • O 0 date: O7-Oq-25 permit: revisions: draNn by GNL checked by: MNJ !E:;,HFEE-_=T N zz Q Q �Q�QQ b QI=�n4p� R b zib<0<<z0 (YTJIIUJ b z0U1� l��QF koTMUA 0 Mlb_ � 1n� II IZIM60wo 1� ) <0)-mDoiz N Q � lu K # <zzjucj Q WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. DUE TO POTENTIAL ALTERING DURING THE PRINTING PROCE!!, DO NOT !GALE DRAW NGl. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO PROCEEDING WITH CONlTRUCTI ON. ANY ALTERATION, REVISION OR SITE CONDITION WARRANTING GHANGE TO THE PLANS MUST BE VERIFIED WITH MWJ HOMES AND THE PROJEGT STRUGTURAL ENGINEER PRIOR TO GONlTRUGTION. ANY GONSTRUGTION TRADE WORKING ON THE PROJECT MUST HAVE KNOWLEDGE OF THE LOCAL AND NATIONAL CODES. MWJ HOMES IS NOT RESPONSIBLE FOR THE KNOWLEDGE OF TRADESPEOPLE THAT ARE NOT EMPLOYED BY MWJ HOMES. ANY ALTERATION TO THE PROJECT MADE WITHOUT PRIOR APPROVAL BY MWJ HOMES AND/OR THE PROJECT STRUCTURAL ENGINEER CAN/MAY/WILL RESULT IN PROJECT DELAYS AND THE GONTRACTOR SHALL AGGEPT FULL RESPONSIBILITY FOR THE G05T AND TIME REQUIRED TO REGTIFY NOTES: ALL EXTERIOR HEADERS MUST BE INSULATED WITH R-10 INSULATION PER NSEG FOR NINOONS KITH OPERABLE OPENINGS MORE THAN 72" ABOVE THE FINISHED GRADE OR SURFACE O BELON, THE LONEST PART OF THE CLEAR OPENING SHALL BE 24" MINIMUM ABOVE THE FLOOR. EXCEPTIONS: - FULLY OPEN NINDONS NHERE A 4" SPHERE MAY NOT r PASS THROUGH OR NHERE FALL PROTECTION DEVICES ARE PROVIDED PER ASTM F 20cf0 OR R612.3 TUB/SHOVER UNITS SHALL HAVE FIRE BLOCKING BETNEEN HALL STUDS AND NATERPROOF SURROUNDS TO +72" FROM DRAIN. GLAZING, INCLUDING NINIDONS NITHIN +72" OF DRAIN, SHALL BE 5AFTEY GLASS. 5HONER FLON 15 LIMITED TO 2.5 GAL/MIN. EXHAUST FANS LARGER THAN 50CFM MAY BE CONNECTED TO 4" SMOOTH HALL VENT PIPE IF RUNS DO NOT EXCEED 20' IN LENGTH. THE MINIMUM SIZE OF FLEX DUCT IS 5" DIAMETER KITH A MAXIMUM RUN OF IS' COMBUSTION AIR REQUIRED FOR ALL FUEL BURNING APPLIANCES EXTERIOR DOORS SHALL BE PROVIDED NI TH LANDINGS OR FLOORS NOT MORE THAN 7-5/4" BELON THE TOP OF THE THRESHOLD PER IRG R311.3 PROVIDE A MOISTURE EXHAUST DUCT FOR THE CLOTHES DRYER TO OUTSIDE AIR. THE DUCT SHALL BE MINIMUM 4" INCH IN DIAMETER OF METAL OR APPROVED MATERIAL KITH SMOOTH SURFACE. THE LENGTH SHALL NOT EXGEED 35 FEET (INCLUDING TRANSITION DUGTS) IF FITTINGS ARE USED, THE MAXIMUM LENGTH SHALL BE REDUCED TO BE PER DRYER OR THE DRYER EXHAUST POKER VENTILATOR'S MFG'S INSTALLATION PER I MG 504.E ENVIRONMENTAL AIR DUCT EXHAUST SHALL TERMINATE NOT LESS THAN 5 FEET FROM A PROPERTY LINE AND 5 FEET FROM OPENINGS INTO A BUILDING PER IMG 501.3.1 THE MIXING VALVE IN A SHOVER (INCLUDING OVER A TUB) SHALL BE PRESSURE BALANGING SET AT 120F. THE HATER HEATER THERMOSTAT GANNOT BE USED TO MEET THESE PROVISIONS PER UPG 408.5 AND 40cl.4 COMBUSTION AIR TO BE PROVIDED TO FURNAGE CLOSET VIA FRESH AIR FROM OUTSIDE. MECH GONTRAGTOR TO FIELD VERIFY EXPANSION TANK, PRESSURE RELIEF VALVE, AND SHUT OFF VALVE TO BE INSTALLED FOR THE HATER HEATER PER UPC, 608.3 BUILDING FRAMING CAVITIES SHALL NOT BE USED AS DUGTS OR PLENUMS. INSTALLATION OF DUGTS SHALL NOT DISPLACE REQUIRED ENVELOPE INSULATION PER NSEG R403.3.5 DUGTS NHICH PENETRATE THE NALL OR FLOOR BETNEEN THE HALL OR FLOOR BETNEEN THE DNELLING AND GARAGE SHALL BE CONSTRUCTED OF A MINIMUM NO. 26 GAGE SHEET STEEL OR APPROVED MATERIAL AND SHALL HAVE NO OPENINGS INTO THE GARAGE PER IRG R302.5.2. SMOKE DETECTOR O IIOV INTERCONNECTED N/ BATTERY BACK-UP. PER IRG 514 O GARBON MONOXIDE DETEGTOR PER IRG 315 HEAT DETECTOR ® GARAGE PER NA STATE AMENDMENT GARAGE NOTES: 1. GARAGE/LIVING SEPARATION, USE 5/5" TYPE 'X' GNB AT GE I L I NG/HALL. NRAP POSTS AND BEAMS. 2. INSULATE ALL HARM HALLS AND CEILING. 3. DOOR BETNEEN GARAGE AND RESIDENCE SHALL BE 1-3/5" MINIMUM THICK SOLID NOOD OR STEEL KITH SOLID OR HONEYCOMB GORE OR 20 MINUTE FIRE RATED EQUIPPED KITH A SELF CLOSING DEVICE. 4. DUCTS IN GARAGE AND DUCTS PENETRATING THE HALLS OR GEILINGS SEPERATIOO THE RESIDENCE FROM THE GARAGE SHALL BE NO. 26 GAGE SHEET STEEL AND HAVE NO OPENINGS INTO THE GARAGE (EGRESS) inN LINEN— N 6 c4 I 50 ciJ l� �N 6 E ?ATH 6� 1Mj ® VTo I N 0 o I I 1 x� NFM - VTO ® o I I u� 0 o I -- FURN N OPT. —OPT N I'-4' 2'-12' �, 3'-82" J-LS D J — O T m z668 O �8 —N W.H. FAN I - =IN IOV S.D. O 6 8 _ ® PER J O I I IOV S.D. ln� ENERGY O r- IdIL?N7 0 m zR Lrym- � IN2868 _ I 15 O RISERS n I IL (L LOi=T 0 W -1 _1 =1cv X Q OUR m 110V S.D. I -I(V II � r 22'-10' 2 5 _53 _5 2 2 2 2 3'- 6'-72 2 = O — 2668 lli 4068 0 0 0 0 o H(V LINEN (3 B 1-PASS 50 �R6 N 0 GFM (�ciD� E ,ATH P -$S ------- -I(V FAN® 2 Cg m VTO _ �6 N I 468 I-2 LINE OF � O 6� 4068 O BI-PASS = —IN I OUTSIDE VAALL IOV S.D. N I1oV S.D. I BE OL N ---PAS--- -IN SE]7RooM SEnRooM r TWO THREE - I (EGRESS) (EGRESS) Uf=f=r=f;k �L-00f;k f=L-�N SEE CGENER?.L NOTES 5C,ALE: 1/4" = I'-O" 12&71 RE015TERED ARC -HI TEGT MIGH L YNE JOHNSON STATE OF NASHINGTONOD �z 'kN Q z,(IwzQQ 0 wQ� 0.Q- Q�4W0Q<zO O Q�UI-J-I�IL 7U1v--dl Jz�m�i�ul,n ���Q�U N L�� � # Q 4Qztu Q � O a a� o UoMo Z M � u'� N `d � W 0 7 • • 0 0 date : O-i-09-25 permit: revisions: drawn by GWL .by checked : MWJ WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. DUE TO POTENTIAL ALTERING DURING THE PRINTING PROCE!!, DO NOT !GALE DRAW 1 NGl. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO PROCEEDING WITH CONlTRUCTI ON. ANY ALTERATION, REVISION OR SITE CONDITION WARRANTING GHANGE TO THE PLANS MUST BE VERIFIED WITH MWJ HOMES AND THE PROJEGT STRUGTURAL ENGINEER PRIOR TO GONlTRUGTION. ANY GONSTRUGTION TRADE WORKING ON THE PROJECT MUST HAVE KNOWLEDGE OF THE LOCAL AND NATIONAL CODES. MWJ HOMES IS NOT RESPONSIBLE FOR THE KNOWLEDGE OF TRADESPEOPLE THAT ARE NOT EMPLOYED BY MWJ HOMES. ANY ALTERATION TO THE PROJECT MADE WITHOUT PRIOR APPROVAL BY MWJ HOMES AND/OR THE PROJECT STRUCTURAL ENGINEER CAN/MAY/WILL RESULT IN PROJECT DELAYS AND THE GONTRAGTOR SHALL AGCEPT FULL RESPONSIBILITY FOR THE GOlT AND TIME REQUIRED TO REGTIFY HANDRAIL: GRIP 1%" - 2" PROJEGTION FROM NALL NO LESS THAN lie". OPEN RAIL: OPEN 5PAGE BETWEEN PICKETS SHALL BE LESS THAN 4" GLEAR - 2X4 STOP 2-2X HEADER FLOOR J015T FIREBLOGK STAIRS: ONCE IN TOP 4 BOTTOM OF RUN BETWEEN STRINGERS 4 ALONG RUN BETWEEN STUDS USABLE SPACE UNDER STAIRS TO BE I HR FIRE GONSTRUGTION 5/8" TYPE 'X' 6.N.B. (TWO LAYERS AT STAIR GEILING) NOS I N6 HANGER � / 0 \-5-2xl2 0 STRINGERS W I 2X4 BLOGKIN6 z (FIRESTOP) i FIREBLOGKS 57A I R I:)r=TA I L. - TYF I GAL. SGAL=: N.T.S. STAIR NOTES: RISER HE 16HT = -7-5/4" MAX. TREND DEPTH = 10" MIN. FLC R. U MAIN FLOC ZX6 NALL SHE, SPAN APPF PAPE SHEA HARL SIMIL MFG. FIN. FLR. T` ROOF TRUSSES PER ENG 1 NEER'S LAYOUT MOM 99= R-60 >OR P.L. _ F-- Ff=f=-R FLOOR TRUSSES PER ENGINEER'S LAYOUT >R P.L. STUD THING 24/16 RAT NG R-25 .OVER E3UILDING R ON TOP OF THING N I TH ,IE SIDING OR AR- INSTALL PER SPEC I F I CATIONS fAI N FLOOR JOISTS PER ENGINEER'S LAYOUT mmmm R-S8 OI Sr=GT 1 ON A -A SEE GENERAL NOTES 5C,ALE: 1/4" = 1'-0" 125-71 REG 15TERED V'�� ARC -HI TEGT MIGH L YNE JOHNSON STATE OF WASHINGTONop M7 �z w Q z<IwzQQ •0.Q- zQ040Q<z0 O z0�n Qd �OOz Jz�m�i0u�,n < # Q 4QtHo� Q � O a a� o UoMo Z M � u'� N `d � �- co .7 � W 0 • 0 0 date : 0-7-09-25 permit: revisions: drawn by .by GNL checked : MNJ WRITTEN DIMENSIONS ON THIS DRAWING SHALL HAVE PRECEDENCE OVER SGALED DIMENSIONS. DUE TO POTENTIAL ALTERING DURING THE PRINTING PROCESS, DO NOT SGALE DRAWINGS. CONTRACTOR SHALL VERIFY ALL D I MENS 1 ONS AND GONI7I TI ONS PRIOR TO PROGEEID I NG WITH GONSTRUGTI ON. ANY ALTERATION, REVISION OR SITE CONDITION WARRANTING CHANGE TO THE PLANS MUST BE VERIFIED WITH MWJ HOMES AND THE PROJECT STRUGTURAL ENGINEER PRIOR TO CONSTRUCTION. ANY GONSTRUGTION TRADE WORKING ON THE PROJECT MUST HAVE <NOWLEDGE OF THE LOCAL AND NATIONAL GODES. MWJ HOMES IS NOT RESPONSIBLE FOR THE KNOWLEDGE OF TRADESPEOPLE THAT ARE NOT EMPLOYED BY MWJ HOMES. ANY ALTERATION TO THE PROJEGT MADE WITHOUT PRIOR APPROVAL BY MWJ HOMES AND/OR THE PROJECT STRUGTURAL ENGINEER GAN/MAY/WILL RESULT IN PROJECT DELAYS AND THE CONTRAGTOR SHALL AGGEPT FULL RESPONSIBILITY FOR THE GOST AND TIME REQU I RED TO REGTI FY �L�GTi� I GAL L�G�ND =Q__ I I O VOLT WALL GONVEN I ENGE OUTLET 110 VOLT WALL C,ONVE 1 N 1 ENGE OUTLET G.>=.�. W 1 TH GROUND FAULT NNTERUPTOR 220 VOLT WALL CONVENIENCE OUTLET 1 10 VOLT WEATHERPROOF OUTLET WITH GAP W.F. I I O VOLT SPLIT WIRED GONVEN 1 ENGE OUTLET DOOR JAMB SW 1 TGH IYFIGAL AT ALL GLOSETS 110 VOLT SMOKE ® DETECTOR I NTERGONNEGTED GABLE OUTLET Q COMPUTER G I RGU I T ® 1 1 O OR 220 VOLT SPEC,1 AL PURPOSE OUTLET O TELEPHONE, $ T.V. GABLE LED GE I L I N(5, MOUNTED L I GHT FIXTURE ® TELEPHONE OUTLET FAN G.F.M. FAN �/TO (VENT TO OUTS I nE) PENDANT LIGHT FIXTURE FEND. ® GH I MES WALL MOUNTED L I GHT F 1 XTURE (OR SCONCE) DOORBELL WALL MOUNTED L I GHT F 1 XTURE W 1 TH F G PULL CHORD I rl THERMOSTAT GE I L I NG FAN PRE -WIRE II FLOOD L I GHT O LOW VOLTAGE LIGHTS O HEAT LAMP 9 GAS OUTLET O CARBON MONOXIDE DETECTOR ❑® UNDERWATER L I GHT SINGLE POLE SW I TGH �Q RECESSED LIGHT FIXTUF;PF- r. SINGLE POLE SWITCH WITH DIMMER DEVICE D I REGTI ONAL RECE55ED'E3 THREE WAY SW I TGH L I GHT F I XTURE '4 FOUR WAY SW 1 TGH F_LF_GTfi;;,'1GAL NOTES: I. INSTALLATION OF BOTH PHONE AND TV SHALL PROVIDE ALL OUTLETS TO BE RUN AS HOME RUNS WITH ALL WIRES TERMINATING AT A SINGLE JUNGTION LOCATION IN EITHER THE HOUSE/UNIT OR 6ARAOE 2. PHONE/TV-GAT 5-ROUGH IN ONLY, GABLE GOMPANY PROVIDES TRIM 5. RANGE TO BE WIRED FOR 220v 4. FAN SIZES: POWDER ROOM-50 GFM WITH 30 MINUTE GRANK TIMER BATHROOMS-50 GFM FAN/L I GHT COMBO WITH 60 MINUTE GRANK TIMER UTILITY ROOM- 75 GFM WITH 24 HOUR PROGRAMMABLE TIMER ��G�o�� I� 37iTi��i�it�f��11� :' ��` � .�` ►1�� 6. TYPES AND LOCATIONS OF LUMINAIRES IN CLOTHES GLOSETS SHALL GOMPLY WITH NEC, 410.16. 7. RECESSED LUMINAIRES INSTALLED IN THE BUILDING THERMAL ENVELOPE ARE SUBJEGT TO THE PROVISIONS OF I RG N 1102.4.5. FIXTURES SHALL BE I G-RATED (FOR ZERO GLEARANGE INSULATION GONTAGT) AND SEALED AIR T16HT 8. DWELLING UNIT REGEPTAGLE OUTLETS SHALL BE INSTALLED SUGH THAT NO POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL SPAGE 15 MORE THAN 6' REGEPTAGLE OUTLET PER NEC, 210.52(A)(1). PROVIDE ADDITION REGEPTAGLES ON PLAN AS REQU I RED ci. LUMINAIRES IN NET OR DAMP LOCATIONS SHALL BE MARKED SUITABLE FOR NET OR DAMP LOCATIONS PER NEC, 410.10. THIS I NGLUDES FIXTURES MOUNTED OVER TUBS AND SHOWERS. 10. PROVIDE TAMPER -RESISTANT REGEPTAGLES IN EVERY K I TGHEN, FAMILY ROOM, DINING ROOM, LIVING ROOM, PARLOR, LIBRARY, DEN, SUNROOM, BEDROOM, RECREATION ROOM, OR SIMILAR ROOM OR AREA OF DWELLING UNITS PER NEC, 406.12. 11. REGEPTAGLE AT GARAGE GE I L I NG SHOULD BE NOTED GFG I AS REQU I RED BY NEC210.5. TH 1 S OUTLET 15 OFTEN USED FOR PORTABLE LIGHTING AND POWER TOOLS. WHERE HABITABLE SPAGE ABOVE, OUTLET BOX SHALL BE STEEL OR FIRE -RATED EQUIVALENT. COMPLY WITH I RG R302.4.2 FOR MEMBRANE PENETRATIONS. THE ANNULAR SPAGE BETWEEN THE WALL MEMBRANE AND THE BOX SHALL NOT EXGEED 8" 12. ARG-FAULT G I RGU I T INTERRUPTER PROTEGTI ON 15 REQU I RED IN K I TGHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, REGREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, OR SIMILAR ROOMS PER NEC, 210.12(A). AV, IN �=L00f;k FLANK SEE GENERAL NOTES SCALE: 1/4" = P-oil PER 2021 WASHINC�TON STATE ENERC�1' GORE SECTION R404.5 "EXTERIOR LIGHTING CONTROLS", WHERE THE TOTAL PERMANENTLY INSTALLED LIGHTING POWER IS GREATER THAN SO WATTS, THE LIGHTING FIXTURE SHALL BE CONTROLLED BY A MANUAL ON AND OFF SW I TGH WHICH PERMITS AUTOMATIC, SHUT OFF ACTIONS, SHALL BE AUTOMATICALL't' SHUT OFF WHEN DAYL I GHT IS PRESENT AND SATISFIES L I GHTI NC-� NEEDS AND CONTROLS THAT 0\/ERRIIDE AUTOMATIC SHUT OFF ACTIONS SHALL NOT BE ALLOWED UNLESS THE OVERRIDE AUTOMATICALLY RETURNS AUTOMATIC CONTROL TO ITS NORMAL OPERATION WITHIN 24 HOURS ELEGTRIG VEHICLE PROVIDE ONE EV READY PARKING STALL- LOCATE AN OUTLET WITH A MINIMUM 40 AMPERE DED I GATED 208/240 BRANGH GIRGUIT WITHIN THE GARAGE FOR EV PLUG IN/GHARGER PLUG IN U���f;k TL00� f=L�N SEE GENERAL NOTES SCALE: 1/4" = 1'-0" F>ER 2021 MASH I NC�TON STATE ENEfizC�Y GODS SECTION 404.2 "INTERIOR L I C�HT I NCB CONTROLS", FERNAMENTL'I' INSTALLED INTERIOR LIGHTING;, FIXTURES SHALL BE GONTROLLEID N I TH EITHER A DIMMER, AN OGGUFANT SENSOR CONTROL OR OTHER CONTROL THAT 15 I NSTALED OR BUILT INTO THE FIXTURE EXGEFTI ON: L I OHTI NO CONTROLS ARE NOT REOU I REE) IN BATHROOMS, HALLVIA'I'S OR L I C�HTI NCB DES I CANED FOR SAFET'i' OR SEGUR I T'Y 125-71 REG I5TERED ARr-HITEGT HIGH L YNE JOHNSO STATE OF HASHINGTON 00 N Q Q Z<Wzzo 0 Q�=�i4 0 Q0<0<<zo �V a zz �a a a � o N � N � cn N UoMa Z M � � �n a) `° 3 to W • O 0 date: 07-Oq-25 permit: revisions: drawn by: GWL che�i«d by: N5uL_A71 ON u -VAI�u 5 ANC N 57 A7 � ON Ou I M N75 5� COS ON N7 a GL I MATE ZONE 5 AND MARINE 4 ( PRESCRIPTIVE ) FENESTRATION U-FACTOR b, J 0.30 SKYLIGHT b U-FACTOR 0.50 GE I L I NS R-VALUE e 60 WOOD FRAME WALL 9,1 R-VALUE 20+5 OR 13+10 FLOOR R-VALUE 30 BELOW -GRADE c,h WALL R-VALUE 10/15/21 INT + 575 SLAB d,f R-VALUE 4 DEPTH 10, 4 FT a. R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation, the compressed R-value of the insulation from Appendix A Table A101.4 of chapter 51-11 C WAC shall not be less than the R-value specified in the table. b. The fenestration U-factor column excludes skylights. c. 10/15/21 +5TB" means R-10 continuous insulation on the exterior of the wall, or R-15 continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. 10/15/21 +5TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "5TB" means R-5 thermal break between floor slab and basement wall. d. R-10 continuous insulation is required under heated slab on grade floors. See Section R402.2.9.1. e. For single rafter- or joist -vaulted ceilings, the insulation may be reduced to R-38 if the full insulation depth extends over the top plate of the exterior wall. f. R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used, it shall meet the requirements for thermal barriers protecting foam plastics. g. For log structures developed in compliance with Standard ICC 400, log walls shall meet the requirements for climate zone 5 of ICC 400. h. Int. (intermediate framing) denotes framing and insulation as described in Section All03.2.2 including standard framing 16 inches on center, 78 percent of the wall cavity insulated and headers insulated with a minimum of R-10 insulation. i. The first value is cavity insulation, the second value is continuous insulation. Therefore, as an example, "R13+10" means R-13 cavity insulation plus R-10 continuous insulation. j. A maximum U-factor of 0.32 shall apply to vertical fenestration products installed in buildings located above 4000 feet in elevation above sea level, or in windborne debris regions where protection of openings is required under Section R301.2.1.2 of the International Residential Code. CLIMATE ZONE 5 AND MARINE 4 ( PROPOSED ) FENESTRATION U-FAGTOR b, j U=.25 SKYLIGHT b U-FACTOR 0.50 GE I L I NS R-VALUE e R-60 WOOD FRAME WALL 9,1 R-VALUE R-25 FLOOR R-VALUE R-55 BELOW -GRADE c,h WALL R-VALUE 10/15/21 INT + 5T5 SLAB d,f R-VALUE $ DEPTH 10, 4 FT INSULATION VALUES HAVE BEEN GALGULATED US I NCB THE 2021 CODE GOMPL I ANGE GALGULATOR. SEE GALGULATI ON PAGKET WILL REOU I RE CONTINUOUS EXTERIOR INSULATION (R-5) AND WILL USE RIGID FOAM. A I LL REOU I RE CONTINUOUS EXTERIOR INSULATION (R-5) AND AI LL USE Z I P-SHEATH I NS OR A S 1 M I LAR PRODUCT. AI LL NOT REQUIRE CONTINUOUS EXTERIOR INSULATION PER ASU's CODE COMPLIANCE CALCULATOR. 5Y57M5 R403.3.5 Duct testing. Ducts shall be leak tested in accordance with WSU RS-33, using the maximum duct leakage rates specified. Exception: A duct air leakage test shall not be required for ducts serving ventilation systems that are not integrated with ducts serving heating or cooling systems. A written report of the results shall be signed by the party conducting the test and provided to the code official. R403.3.6 Duct leakage. The total leakage of the ducts, where measured in accordance with Section R403.3.3, shall be as follows: 1. Rough -in test: Total leakage shall be less than or equal to 4.0 cfm (113.3 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the system, including the manufacturer's air handler enclosure. All registers shall be taped or otherwise sealed during the test. If the air handler is not installed at the time of the test, total leakage shall be less than or equal to 3.0 cfm (85 L/min) per 100 square feet (9.29 m2) of conditioned floor area. 2. Postconstruction test: Leakage to outdoors shall be less than or equal too cfm (113.3 Umin) per 100 square feet (9.29 m2) of conditioned floor area or total leakage shall be less than or equal to 4 cfm (113.3 Umin) per 100 square feet (9.29 m2) of conditioned floor area when tested at a pressure differential of 0.1 inches w.g. (25 Pa) across the entire system, including the manufacturer's air handler enclosure. All register boots shall be taped or otherwise sealed during the test. 3. Test for ducts within thermal envelope: Where all ducts and air handlers are located entirely within the building thermal envelope, total leakage shall be less than or equal to 8.0 cubic feet per minute (226.6 L/min) per 100 square feet (9.29 m2) of conditioned floor area. For forced air ducts, a maximum of 10 linear feet of return ducts and 5 linear feet of supply ducts may be located outside the conditioned space. All metallic ducts located outside the conditioned space must have both transverse and longitudinal joints sealed with mastic. If flex ducts are used, they cannot contain splices. Flex duct connections must be made with nylon straps and installed using a plastic strapping tensioning tool. Ducts located in crawl spaces do not qualify for this exception. L C=fi I C,L FO^ER ANC L I SH7I NS 5`I'57EY5 R404.1 Lighting equipment. All permanently installed lighting fixtures, excluding kitchen appliance lighting fixtures, shall contain only high -efficacy lighting sources. R404.1.1 Exterior lighting. Connected exterior lighting for residential buildings shall comply with Section C405.5. Exceptions: Solar -powered lamps not connected to any electrical service. R404.1.2 Fuel gas lighting equipment. Fuel gas lighting systems shall not have continuously burning pilot lights. R404.2 Interior lighting controls. Permanently installed interior lighting fixtures shall be controlled with either a dimmer, an occupant sensor control or other control that is installed or built into the fixture. Exception: Lighting controls shall not be required for the following: 1. Bathrooms. 2. Hallways. 3. Lighting designed for safety or security. R404.3 Exterior lighting controls. Where the total permanently installed exterior lighting power is greater than 30 watts, the permanently installed exterior lighting shall comply with the following: 1. Lighting shall be controlled by a manual on and off switch which permits automatic shut-off actions. Exception: Lighting serving multiple dwelling units. 2. Lighting shall be automatically shut off when daylight is present and satisfies the lighting needs. 3. Controls that override automatic shut-off actions shall not be allowed unless the override automatically returns automatic control to its normal operation within 24 hours. Additional Items: 1. Provide door blower test affidavit by final building inspection. 2. Provide (1) programmable thermostat. 3. A minimum of 75% of all permanent lighting shall be high efficiency. 4. Building framing cavities shall not be used for ducts or plenums. Installation of ducts in exterior walls, floors, or ceilings shall not displace required envelope insulation. 7AE3L�40&.2- 64*ro' EOVAL I ZA71 ON CREW 75 CRED I TS SYSTEM DESCRIPTION OF PRIMARY HEATING SOURCE ALL OTHER GROUP R-2 a TYPE FOR COMBUSTION HEATING EQU I PMENT MEETING O O MINIMUM FEDERAL EFFICIENCY STANDARDS FOR THE EOU I PMENT L 1 STED IN TABLE 0405.3.2(5) OR 0403.3.2(6) FOR AN INITIAL HEATING SYSTEM USING A HEAT PUMP 1.5 0 THAT MEETS FEDERAL STANDARDS FOR THE 2 EQU I PMENT L I STED IN TABLE C403.3.2(2) AND SUPPLEMENTAL HEATING PROVIDED BY ELECTRIC RESISTANCE OR A COMBUSTION FURNACE MEETING M I N I MUM STANDARDS L I STED I N TABLE G405.5.2(5) b FOR HEATING SYSTEM BASED ON ELECTRIC 0.5 -0.5 RES 1 STANCE ONLY (EITHER FORGED AIR OR ZONAL) FOR HEATING SYSTEM USING A HEAT PUMP THAT 5.0 2.0 MEETS FEDERAL STANDARDS FOR THE EaU I PMENT L I STED IN TABLE 0403.3.2(2) OR G405.5.2(Q) OR AIR TO RATER HEAT PUMP UNITS THAT ARE GONF I CURED TO PROVIDE BOTH HEATING AND COOLING AND ARE RATED IN ACCORDANCE WITH AHRI 550/5g0 FOR HEATINS SYSTEM BASED ON ELECTRIC 2.0 O RESISTANCE WITH: 1. INVERTER -DRIVEN DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM INSTALLED IN THE LARGEST ZONE IN THE DWELL I NS, OR 2. WITH 2KA OR LESS TOTAL INSTALLED HEATING CAPACITY PER DWELL I NS a. See Section R401.1 and residential building in Section R202 for Group R-2 scope. b. The gas back-up furnace will operate as fan -only when the heat pump is operating. The heat pump shall operate at all temperatures above 38°F (3.3°C) (or lower). Below that "changeover" temperature, the heat pump would not operate to provide space heating. The gas furnace provides heating below 380F (3.3°C) (or lower). c. Additional points for the HVAC system are included in Table R406.3. R406.3 Additional energy efficiency requirements. Each dwelling unit in a residential building shall comply with sufficient options from Tables R406.2 and R406.3 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit:........................................................................................... 5.0 credits Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building greater than 500 square feet of heated floor area but less than 1500 square feet. 2. Medium Dwelling Unit: 8.0 credits All dwelling units that are not included in #1, #3 or #4. 3. Large Dwelling Unit: 9.0 credits Dwelling units exceeding 5000 square feet of conditioned floor area. 4. Dwelling units serving Group R-2 occupancies.................................................6.5 credits See Section R401.1 and residential building in Section R202 for Group R-2 scope. 5. Additions 150 square feet to 500 square feet :................................................... 2.0 credits The drawings included with the building permit application shall identify which options have been selected and the point value of each option, regardless of whether separate mechanical, plumbing, electrical, or other permits are utilized for the project. 7A5LE R40& .5 6 CREW 175 CREDITS OPTION DESCRIPTION ALL OTHER GROUP R-2 b 1. EFFICIENT BUILDING ENVELOPE OPTIONS ONLY ONE OPTION FROM ITEMS 1.1 THROUGH 1.4 MAY BE SELECTED IN THIS CATESORY. COMPLIANCE WITH THE CONDUCTIVE UA TARGETS 15 DEMONSTRATED US 1 NS SECTION R402.1.5, TOTAL UA ALTERNATIVE, AHERE [1-(PROPOSED UA/TARGET UA)] > THE REGU I RED YUA REDUCTION PRESCRIPTIVE COMPLIANCE 15 BASED ON TABLE 0.5 0.5 I.I R402.1.5 WITH THE FOLLOWINS MODIFICATIONS: VERTICAL FENESTRATION U = 0.22. PRESCRIPTIVE COMPLIANCE 15 BASED ON TABLE 1.0 1.0 R402.1.5 WITH THE FOLLOWING MODIFICATIONS: VERTICAL FENESTRATION U = 0.25 FLOORR-38 1.2 SLAB ON GRADE R-1 O PERIMETER AND UNDER ENTIRE SLAB XXX BELOW GRADE SLAB R-10 PERIMETER AND UNDER ENTIRE SLAB OR COMPLIANCE BASED ON SECTION R402.1.5: REDUCE THE TOTAL CONDUCTIVE UA BY 15%. A ;1] GISTEMir-L YNE JOi-IN50 STATE OF WASHINGTON V � !ta -_ 0 �0 T UA --I0 Cn w 2 VI Z In LU V Z VI `l V L VI 0 N DATE: 10-06-24 REV 1 S 1 ONS : DRAWN BY: MWJ GHEGKED BY: MWJ N®I FOR FOOTNOTES, SEE SHEET EN-3 CREDITS CREDITS CREDITS OPTION DESCRIPTION OPTION DE50R1 PTI ON OPTION DE50R1 PTI ON ALL OTHER GROUP R-2 b ALL OTHER GROUP R-2 b ALL OTHER GROUP R-2 b 1. EFFICIENT BUILDING ENVELOPE OPTIONS 3. HIGH EFFICIENCY HVAG EQUIPMENT OPTIONS AIR -TO -WATER HEAT PUMP W 1 TH MINIMUM GOP OF 1.0 N/A 3.2 AT 47 ° F, RATED IN ACCORDANCE WITH AHR I ONLY ONE OPT I ON FROM 1 TEM5 1.1 THROUGH 1.4 MAY BE SELECTED I N TH 15 CATEGORY. ONLY ONE OPTI ON FROM ITEMS 5.1 THROUGH 5.1 O MAY BE SELECTED I N TH 15 CATE6ORY. 17EM 550/5g0 BY AN ACCREDITED OR CERTIFIED TE5T1 N6 COMPLIANCE WITH THE CONDUCTIVE UA 7AR6E75 15 DEMONSTRATED USING SECTION 5.11 MAY BE TAKEN WITH ITEMS 5.1 AND 3.30 ONLY. LAB. R402.1.5, TOTAL UA ALTERNATIVE, WHERE [1-(PROPOSED UA/TARGET UA)] > THE REQU I RED %UA REDUCTION 3.ga d TO QUALIFY TO CLAIM THIS CREDIT, THE BUILDING PERMIT DRAW I N65 SHALL SPECIFY THE OPTION FOR A SYSTEM TYPE I I N TABLE R406.2 : 1.0 1.0 BEIN6 SELECTED, THE HEATED FLOOR AREA PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE 1.5 0.5 ENER6Y STAR RATED (U.S. NORTH) GAS OR CALCULATION, THE HEATI N6 EQUIPMENT 7YPE(5), R402.1.3 WITH THE FOLLOW I N6 MOD I F I GAT I ON5: PROPANE FURNACE WITH MINIMUM AFUE OF 015% THE MINIMUM EQUIPMENT EFFICIENCY, AND TOTAL INSTALLED HEAT CAPACITY (BY EQUIPMENT TYPE). VERTICAL FENESTRATION U = O.IS OR GE I L I N6 AND 51 N6LE-RAFTER OR JO I ST-VAULTED 3'I a ENERGY STAR RATED (U.S. NORTH) GAS OR R-60 ADVANCED PROPANE BOILER WITH MINIMUM AFUE OF q0%. GAS -FIRED HEAT PUMP(5) MEETING ANSI Z21.40.2 AND 1.5 1.5 WOOD FRAME WALL R-21 I NT PLUS R-12 01 TO QUALIFY TO CLAIM THIS GRED I T THE BUILDING Z21.40.4 OR GSA, WITH A MINIMUM UEF OF 1.15. FLOOR R-55 PERM 1 T DRAW I N65 SHALL SPECIFY THE OPT 1 ON 3 ct FOR R-2 OCCUPANCY, GAS-F I RED HEAT PUMP(S) 13 BASEMENT WALL R-21 I NT PLUS R-12 01 5EIN6 SELECTED AND SHALL SPECIFY THE HEAT I N6 MEET I N6 ANSI Z21.40.2 AND Z21.40.4 OR GSA, W 1 TH A SLAB ON GRADE R-1 O PERIMETER AND UNDER EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT MINIMUM UEF OF 1.15, SHALL SERVE ALL UNITS. ENTIRE SLAB EFFICIENCY. BELOW GRADE SLAB R-10 PERIMETER AND UNDER ENTIRE SLAB COMBINATION WATER HEATING AND SPACE HEATING 2.5 2.5 FOR SECONDARY HEATI N6 SYSTEM SERV I N6 0.5 0.5 SYSTEM SHALL INCLUDE ONE OF THE FOLLOW I N6: OR SYSTEM TYPE 2 IN TABLE R406.2: GAS-F I RED HEAT PUMP WATER HEATERS) MEETI N6 COMPLIANCE BASED ON SECTION R402.I.S: AIR -SOURCE CENTRALLY DUCTED HEAT PUMP W17H TIER 2 OF THE NEEA ADVANCED WATER HEA7IN6 REDUCEDUC RE THE TOTAL CONDUCTIVE UA BY 22.5%. MINIMUM H5PF OF q.5 SPECIFICATION FOR GAS -FUELED RESIDENTIAL OR 5TORA6E WATER HEATERS VERSION 1.0. PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE 2.5 2.0 3.2a ENERGY STAR RATED (U.S. NORTH) GAS OR OR R402.1.3 W 1 TH THE FOLLOW I N6 MOD I F I GAT 1 ONS: PROPANE BO 1 LER W 1 TH MINIMUM AFUE OF QO%. FOR R-2 OCCUPANCY, GAS-F I RED HEAT PUMP VERT 1 GAL FENF-57RA71 ON U = 0.15 TO QUALIFY TO CLAIM TH 15 CREDIT, THE BU I LD I N6 WATER HEA7ER(5) MEET 1 N6 T 1 ER 2 OF THE NEEA GE I L I N6 AND 5I N6LE-RAFTER OR JO I5T-VAULTED PERM 1 T DRAW I N65 SHALL SPECIFY THE OPT 1 ON 5.10 f ADVANCED WATER HEAT 1 N6 SPECIFICATION FOR R-60 ADVANCED BEIN6 SELECTED AND SHALL SPECIFY THE HEATI N6GAS-FUELED RESIDENTIAL STORAGE WATER WOOD FRAME WALL R-21 I NT PLUS R- 16 01 EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT HEATERS VERSION 1.0., SHALL SERVE ALL UNITS. FLOOR R-45 EFFICIENCY. OR '4 BASEMENT WALL R-21 I NT PLUS R- 16 CI FOR R-2 OCCUPANCY, GAS-F I RED HEAT PUMP(5) SLAB ON GRADE R-20 PERIMETER AND UNDER AIR -SOURCE, CENTRALLY DUCTED HEAT PUMP 0.5 N/A MEETING ANSI Z21.40.2 AND Z21.40.4 OR GSA, WITH ENTIRE SLAB WITH MINIMUM HSPF 2 OF 8.1 (HSPF OF q .5) . A MINIMUM UEF OF 1.15, SHALL SERVE ALL UNITS. BELOW GRADE SLAB R-20 PERIMETER AND UNDER I N AREAS WHERE THE WINTER DES 16N TO QUALIFY TO CLAIM THIS CREDIT, THE BU I LD I N6 ENTIRE SLAB TEMPERATURE AS SPECIFIED IN APPENDIX RG PERMIT DRAW I N65 SHALL SPECIFY THE OPTION OR 15 23 °F OR BELOW, A GOLD CLIMATE HEAT PUMP 5EIN6 SELECTED AND SHALL SPECIFY THE WATER COMPLIANCE BASED ON SECTION R402.1.5: FOUND ON THE NEEP CC ASHP QUALIFIED HEATER EQUIPMENT TYPE AND THE MINIMUM REDUCE THE TOTAL CONDUCT I VE UA BY 30% 3 3 a,c,d PRODUCT LIST SHALL BE USED. EQUIPMENT EFFICIENCY AND, FOR SOLAR WATER . HEAT I N6 SYSTEMS, THE CALCULATION OF THE TO QUALIFY TO CLAIM THIS GRED I T, THE MINIMUM ENERGY SAVINGS. BU I LD I N6 PERMIT DRAW I N65 SHALL SPECIFY 2. AIR LEAKA6E CONTROL AND EFFICIENT VENTILATION OPTIONS THE OPTION BEIN6 SELECTED AND SHALL ONLY ONE OPT 1 ON FROM ITEMS 2.1 THROUGH 2.5 MAY BE SELECTED IN TH 15 CATE6ORY. SPECIFY THE HEAT I N6 EQUIPMENT TYPE AND CONNECTED THERMOSTAT MEET I N6 ENERGY STAR 0.5 0.5 THE MINIMUM EQUIPMENT EFFICIENCY. CERT 1 F I ED SMART 7HERMO57A75/EPA ENERGY 57AR SPECIFICATIONS. COMPLIANCE BASED ON SECT 1 ON R402.4.1.2: 1.0 1.0 3 c TO QUAL 1 FY TO CLAIM THIS GRED 1 T, THE BU I LD I N6 CLOSED -LOOP GROUND SOURCE HEAT PUMP; W 1 TH 1.5 1.0 REDUCE THE TESTED AIR LEAKAGE TO 2.0 AIR A MINIMUM GOP OF 5.3 PERMIT DRAW I N65 SHALL SPECIFY THE OPTION CHAN6E5 PER HOUR MAXIMUM AT 50 PASCALS, OR OR BEIN6 SELECTED AND SHALL SPECIFY THE FOR R-2 OCCUPANCIES, OPTIONAL COMPLIANCE THERMOSTAT MODEL. BASED ON SECTION R402.4.1.2: REDUCE THE TESTED OPEN LOOP WATER SOURCE HEAT PUMP WITH A AIR LEAKAGE TO 0.25 GFM/F72 MAXI MUM AT 50 3 a, 1 MAXIMUM PUMP I N6 HYDRAULIC HEAD OF 150 FEET AND MINIMUM GOP OF 3.6. 4. HIGH EFFICIENCY HVAC DISTRIBUTION SYSTEM OPT I ON5 PASCALS TO QUALIFY TO CLAIM THIS CREDIT, THE BU I LD I N6 AND PERM 1 T DRAW I N65 SHALL SPECIFY THE OPT 1 ON ALL WHOLE HOUSE VENTILATION REQUIREMENTS AS BEIN6 SELECTED AND SHALL SPECIFY THE HEATING HVAC EQUIPMENT AND ASSOCIATED DUCT 0.5 N/A 2.1 DETERMINED BY SECTION M 1505.3 OF THE EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT SYSTEM(5) 1 N5TALLAT 1 ON SHALL COMPLY WITH THE INTERNATIONAL RES I DENTI AL CODE OR SEGTI ON EFF I G I ENGY. REQUIREMENTS OF SEGTI ON R403.3.2. 403.5 Off NTERNAT I ONAL MECHANICAL CODE ELECTRIC RESISTANCE HEAT, HYDRON I G HEATING SHALL BE MET W 1 TH A HEAT RECOVERY DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM, ZONAL 1.5 2.0 AND DUCTLESS HEAT PUMPS ARE NOT PERMITTED VENTILATION SYSTEM WITH MINIMUM SENSIBLE CONTROL: IN HOMES WHERE THE PRIMARY SPACE UNDER 7HI5 OPTION. HEAT RECOVERY EFFICIENCY OF 0.65. HEAT I N6 SYSTEM 15 ZONAL ELECTRIC HEAT I N6, A DIRECT COMBUSTION HEAT I N6 EQUIPMENT W 1 TH TO QUALIFY TO CLAIM THIS GRED 1 T, THE BU I LD I N6 DUCTLESS MINI -SPLIT HEAT PUMP SYSTEM W 1 TH A AFUE LE55 THAN 50% IS NOT PERMITTED UNDER PERM 1 T DRAW I N65 SHALL SPECIFY THE OPT 1 ON MINIMUM HSPF 2 OF q (HSPF OF 10.0) SHALL BE THIS OPTION. BEIN6 SELECTED, THE MAXIMUM TESTED BU I LD I N6 INSTALLED AND PROVIDE HEAT 1 N6 TO THE TO QUALIFY TO CLAIM THIS GRED 1 T, THE BU I LD I N6 AIR LEAKAGE, AND SHALL SHOW THE QUAL I FY I N6 LARGEST ZONE OF THE HOUS I N6 UNIT. PERMIT DRAW I N65 SHALL SPECIFY THE OPTION VENTILATION SYSTEM AND 175 CONTROL SEQUENCE TO QUALIFY TO CLAIM TH 15 CREDIT, THE BU I LD I N6 BEIN6 SELECTED AND SHALL SPECIFY THE HEAT 1 N6 OF OPERATION. PERMIT DRAWINGS SHALL SPECIFY THE OPTION EQUIPMENT TYPE AND SHALL SHOW THE LOCATION BEIN6 SELECTED AND SHALL SPECIFY THE Idj OF THE HEATI N6 AND COOL I N6 EQUIPMENT AND COMPLIANCE BASED ON SECTION R402.4.1.2: 1.5 1.5 HEATI N6 EQUIPMENT TYPE AND THE MINIMUM ALL THE DUCTWORK. REDUCE THE TESTED AIR LEAKAGE TO 1.5 AIR EQUIPMENT EFFICIENCY. I CHANGES PER HOUR MAXIMUM AT 50 PASCALS, OR FOR R-2 OCCUPANCIES, OPTIONAL COMPLIANCE XXX AIR -SOURCE, CENTRALLY DUCTED HEAT PUMP WITH 1.0 N/A 5. EFFICIENT WATER HEAT 1 N6 OPT 1 ON5 BASED ON SECTION R402.4.1.2: REDUCE THE TESTED XXX MINIMUM HSPF 2 OF q.4 (H5PF OF 11.0). ONLY ONE OPTION FROM ITEMS 5.5 THROUGH 5.5 MAY BE SELECTED IN THIS CATEGORY. ITEMS AIR LEAKA612 TO 0.20 GFM/FT MAXIMUM AT 50 XXX A CENTRALLY DUCTED AIR SOURCE GOLD CLIMATE 5.1 AND 5.2 MAY BE COMBINED WITH ANY OPTION. PASCALS XXX VARIABLE CAPACITY HEAT PUMP (GC VCHP) FOUND AND XXX XXX ON THE NEEP Cr-. VCHP QUALIFIED PRODUCT L I5T A DRAIN WATER HEAT RECOVERY UN 1 T(5) SHALL BE 0.5 0.5 ALL WHOLE HOUSE VENTILATION REGU I REMENT5 AS W 1 TH A MINIMUM OF q HSPF 2 (1 O HSPF) MAY BE INSTALLED, WH I GH CAPTURES WA57E WATER HEAT 2.2 DETERMINED BY SECTION M 1505.3 OF THE USED TO SAT 15FY THIS REQUIREMENT. FROM AT LEAST TWO SHOWERS, I NCLUD I N6 INTERNATIONAL RESIDENTIAL CODE OR SECTION IN AREAS WHERE THE WINTER DE516N TUB/SHOWER COMBINATIONS. IT 15 ACCEPTABLE, 403.8 OF THE INTERNATIONAL MECHANICAL CODE 3'6 a TEMPERATURE AS SPECIFIED IN APPENDIX RC 15 BUT NOT REQU I RED, FOR SINK WATER TO BE SHALL BE MET WITH A HEAT RECOVERY VENTILATION 25°F OR BELOW, AN AIR SOURCE CENTRALLY CONNECTED. UNIT SHALL HAVE A MINIMUM SYSTEM W 1 TH MINIMUM SENSIBLE HEAT RECOVERY DUCTED HEAT PUMP SHALL BE A GOLD CLIMATE EFFICIENCY OF 40% IF INSTALLED FOR EQUAL FLOW EFFICIENCY OF 0.75. VARIABLE CAPACITY HEAT PUMP AS L 157ED ON THE OR A M I N I MUM EFF I G I ENGY OF 54% 1 F I N5TALLED TO QUALIFY TO CLAIM THIS CREDIT, THE BU I LD I N6 NEEP QUALIFIED PRODUCT LIST. 3' FOR UNEQUAL FLOW. SUCH UN 1 T5 SHALL BE RATED PERMIT DRAW I N65 SHALL SPECIFY THE OPTION XXX TO QUALIFY TO CLAIM THIS GRED I T, THE BU I LD I N6 IN ACCORDANCE W 1 TH 05A 555.1 OR I APMO 160 BEIN6 SELECTED AND SHALL SPECIFY THE MAXIMUM XXX PERM 1 T DRAW I N&S SHALL SPECIFY THE OPT 1 ON 346-2017 AND BE 50 LABELED. TESTED BU I LD I N6 AIR LEAKAGE AND SHALL SHOW BEIN6 SELECTED AND SHALL SPECIFY THE HEAT I N6 TO QUALIFY TO CLAIM THIS GRED 1 T, THE BU I LD I N6 THE HEAT RECOVERY VENTILATION SYSTEM. EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT PERMIT DRAW I N65 SHALL INCLUDE A PLUMB 1 N6 EFFICIENCY. D I ARAM THAT SPECIFIES THE DRAIN WATER HEAT RECOVERY UN175 AND THE PLUMBING LAYOUT COMPLIANCE BASED ON SECTION R402.4.1.2: 2.0 2.0 NEEDED TO I N57ALL 17. LABELS OR OTHER REDUCE THE TESTED AIR LEAKAGE TO 0.6 AIR DU07LE55 5PL 1 T SYSTEM HEAT PUMPS WITH NO 2.0 5.0 DOCUMENTATION SHALL BE PROVIDED THAT CHAN6E5 PER HOUR MAXIMUM AT 50 PASCALS, OR ELEGTR I C RES I STANCE HEAT 1 N6 IN THE PRIMARY DEMONSTRATES THAT THE UN 1 T COMPLIES W 1 TH FOR R-2 OCCUPANCIES, OPTIONAL COMPLIANCE L I V I N6 AREAS. A DU07LE55 HEAT PUMP SYSTEM THE STANDARD. BASED ON SECT 1 ON R402.4.1.2- REDUCE THE W 1 TH A MINIMUM HSPF 2 OF q (HSPF OF 10) SHALL BE TESTED AIR LEAKAGE TO 0.15 CFM/FT2 MAXI MUM AT 51 ZED AND INSTALLED TO PROVIDE HEAT TO ENTIRE 50 PASCALS DWELLING UNIT AT THE DESIGN OUTDOOR AIR FOR COMPACT HOT WATER DISTRIBUTION SYSTEM 0.5 0.5 AND TEMPERATURE. GRED 1 T, THE VOLUME SHALL STORE NOT MORE THAN EXCEPTION: IN HOMES WITH TOTAL HEATING LOADS 16 OUNCES OF WATER BETWEEN THE NEAREST ALL WHOLE HOUSE VENTILATION REQU I REMENT5 3.7 OF 24,000 OR LE55 US 1 N6 MULTI -ZONE MINI -5PL 1 T SOURCE OF HEATED WATER AND THE TERMINATION AS DETERMINED BY SECTION M1505.3 OF THE SYSTEMS WITH NOMINAL RATIN65 OF 24,000 OR OF THE FIXTURE SUPPLY PIPE WHERE CALCULATED 2.3 INTERNATIONAL RESIDENTIAL CODE OR SECTION LESS, THE MINIMUM HSPF 5 TO CLAIM THIS CREDIT U51 N6 SECTION R403.5.2. CONSTRUCTION 403.5 OF THE INTERNATIONAL MECHANICAL CODE SHALL BE S.IQ HSPF 2 (OR q H5PF). DOCUMENTS SHALL INDICATE THE OUNCES OF SHALL BE MET WITH A HEAT RECOVERY TO QUALIFY TO CLAIM THIS GRED I T, THE BU I LD I N6 3'2 WATER IN P I P I N6 BETWEEN THE HOT WATER SOURCE VENTILATION SYSTEM W17H MINIMUM SENSIBLE PERMIT DRAWINGS SHALL SPECIFY THE OPTION AND THE TERMINATION OF THE FIXTURE SUPPLY. HEAT RECOVERY EFFICIENCY OF 0.50. DUCT BEIN6 SELECTED, THE HEATED FLOOR AREA WHEN THE HOT WATER SOURCE IS THE NEAREST INSULATION SHALL COMPLY WITH SECTION CALCULATION, THE HEATING EQUIPMENT 7YPE(5), PRIMED PLUMBING LOOP OR TRUNK, THIS MUST BE R403.3.2 . TO QUALIFY TO CLAIM TH 15 CREDIT, THE BU I LD I N6 THE MINIMUM EQUIPMENT EFFICIENCY, AND TOTAL PRIMED W 1 TH AN ON DEMAND REO I ROULA71 ON PUMP PERM1 T DRAW I N65 SHALL SPECIFY THE OP71 ON INSTALLED HEAT CAPAC 1 TY (BY T TYPE). . AND MUST RUN A DE7 I GATED AMBIENT RETURN LINE FROM THE FURTHEST FIXTURE OR END OF LOOP TO BEIN6 SELECTED AND SHALL SPECIFY THE L THE WATER HEATER. MAXIMUM TESTED BU I LD I N6 AIR LEAKAGE AND SHALL SHOW THE HEAT RECOVERY VENTILATION TO QUALIFY FOR THIS GRED I T, THE DWELL I N6 MUST SYSTEM. HAVE A MINIMUM OF 1.5 BATHROOMS. FOR FOOTNOTES, SEE SHEET EN-3 Iz871 \\I;AP-C-H:ITE G 1ED GT � MIGH EL , JOHNSON STATE OF WRSHINOTON V � -_ 0 0<D-10 _ CQ w O 2 VI V VI i1 V VI 0 N tu I DATE: 10-06-24 REV 1510N5: DRAWN BY: C,HEGKED BY: MWJ MWJ N 7A5L� 406 ,5 C,,ON7N�� CREDITS OPTION DESCRIPTION ALL OTHER GROUP R-2 b WATER HEATING SYSTEM SHALL INCLUDE THE 0.5 0.5 FOLLOWING: ENERGY STAR RATED GAS OR PROPANE WATER HEATER WITH A MINIMUM UEF OF 0.50. TO QUALIFY TO CLAIM THIS CREDIT, THE BUILDING PERMIT DRAW I NGS SHALL SPECIFY THE OPTION BEING SELECTED AND SHALL SPECIFY THE WATER HEATER EaU I PMENT TYPE AND THE MINIMUM EOU I PMENT EFFICIENCY. WATER HEATING SYSTEM SHALL INCLUDE ONE OF 1.0 1.0 THE FOLLOWING: ENERGY STAR RATED GAS OR PROPANE WATER HEATER WITH A MINIMUM UEF OF O.Q I OR SOLAR WATER HEATING SUPPLEMENTING A MINIMUM STANDARD WATER HEATER. SOLAR WATER HEATING WILL PROVIDE A RATED MINIMUM SAV I NGS OF 85 THERMS OR 2000 KWH BASED ON THE SOLAR RATING AND CERTIFICATION CORPORATION (5RCO) ANNUAL PERFORMANCE OF rj t� 0G-500 CERTIFIED SOLAR WATER HEATING SYSTEM OR WATER HEATER HEATED BY GROUND SOURCE HEAT PUMP MEETING THE REaU I REMENTS OF OPTION 5.4. TO DUAL I FY TO CLAIM THIS CREDIT, THE BUILDING PERMIT DRAW I NGS SHALL SPECIFY THE OPTION BEING SELECTED AND SHALL SPECIFY THE WATER HEATER EaU I PMENT TYPE AND THE MINIMUM EG2U I PMENT EFFICIENCY AND, FOR SOLAR WATER HEATING SYSTEMS, THE CALCULATION OF THE MINIMUM ENERGY SAV I NGS. WATER HEATING SYSTEM SHALL INCLUDE ONE OF 1.5 1.5 THE FOLLOWING: GAS-F I RED HEAT PUMP WATER HEATER(5) MEETING TIER 2 OF THE NEEA ADVANCED WATER HEATING SPECIFICATION FOR GAS -FUELED RESIDENTIAL STORAGE WATER HEATERS VERSION I.O. OR FOR R-2 OCCUPANCY, GAS-F I RED HEAT PUMP WATER HEATER(5) MEETING TIER 2 OF THE NEEA AD\/ANCED WATER HEATING SPECIFICATION FOR GAS -FUELED RESIDENTIAL STORAGE WATER HEATERS \/ER51ON I.O. SHALL SUPPLY DOMESTIC HOT WATER TO ALL UNITS. OR FOR R-2 OCCUPANCY, GAS-F I RED HEAT PUMP WATER HEATER(5) MEETING ANSI Z21.40.2 AND Z21.40.4 OR 05A, WITH A MINIMUM UEF OF 1.15, SHALL SUPPLY DOMESTIC HOT WATER TO ALL UNITS. TO QUALIFY TO CLAIM THIS CREDIT, THE BUILDING PERMIT DRAW I NGS SHALL SPECIFY THE OPTION BEING SELECTED AND SHALL SPECIFY THE WATER HEATER ECU I PMENT TYPE AND THE MINIMUM EG2U I PMENT EFFICIENCY AND, FOR SOLAR WATER HEATING SYSTEMS, THE CALCULATION OF THE MINIMUM ENERGY SAYI NGS. WATER HEATING SYSTEM SHALL INCLUDE ONE OF 2.0 2.5 THE FOLLOWING: ELECTRIC HEAT PUMP WATER HEATER MEETING THE STANDARDS FOR TIER III OF NEEA'5 AD\ANCED WATER HEATI N6 SPECIFICATION OR FOR R-2 OCCUPANCY, ELECTRIC HEAT PUMP WATER HEATER(S), MEETING THE STANDARDS FOR TIER III 5.6 OF NEEA'S ADYANOED WATER HEATI N6 SPECIFICATION, SHALL SUPPLY DOMESTIC HOT WATER TO ALL UNITS. IF ONE WATER HEATER 15 5ERY I NG MORE THAN ONE DWELLING UNIT, ALL HOT WATER SUPPLY AND RECIRCULATION PIPING SHALL BE INSULATED WITH R-5 MINIMUM PIPE INSULATION. TO DUAL I FY TO OLA I M TH IS ORED 17, THE BU I LD I NG PERM 1 T DRAW 1 NGS SHALL SPECIFY THE OPTION BEING SELECTED AND SHALL SPECIFY THE WATER HEATER EaU I PMENT TYPE AND THE MINIMUM EaU I PMENT EFFICIENCY. WATER HEATING SYSTEM SHALL INCLUDE ONE OF 2.5 3.0 THE FOLLOWING: ELECTRIC HEAT PUMP WATER HEATER WITH A MINIMUM UEF OF 2.1 AND UTILIZING A SPLIT SYSTEM CONFIGURATION WITH THE AIR -TO -REFRIGERANT HEAT EXCHANGER LOCATED OUTDOORS. EOU I PMENT SHALL MEET SECTION 4, REG2UIREMENT5 FOR ALL UNITS, OF THE NEEA STANDARD ADVANCED WATER HEATING SPECIFICATION WITH THE UEF NOTED ABO\/E OR FOR R-2 OCCUPANCY, ELECTRIC HEAT PUMP WATER HEATER(5), MEETING THE STANDARDS FOR TIER III OF NEEA'S ADVANCED WATER HEATING SPECIFICATION AND UTILIZING A SPLIT SYSTEM CONFIGURATION WITH THE AIR -TO -REFRIGERANT HEAT EXCHANGER LOCATED OUTDOORS, SHALL SUPPLY DOMESTIC HOT WATER TO ALL UNITS. IF ON WATER HEATER 15 SERVING MORE THAN ONE DWELLING UNIT, ALL HOT WATER SUPPLY AND RECIRCULATION PIPING SHALL BE INSULATED WITH R-5 MINIMUM PIPE INSULATION. TO QUALIFY TO CLAIM THIS CREDIT, THE BUILDING PERMIT DRAW I NGS SHALL SPECIFY THE OPTION BEING SELECTED AND SHALL SPECIFY THE WATER HEATER EaU I PMENT TYPE AND THE MINIMUM EOU I PMENT EFFICIENCY. a. An alternative heating source sized at a maximum of 0.5 Watts/ftZ (equivalent) of heated floor area or 500 Watts, whichever is bigger, may be installed in the dwelling unit. b. See Section R401.1 and residential building in Section R202 for Group R-2 scope. c. Option 3.11 can only be taken with Options 3.1 and 3.3. To qualify to claim Option 3.11 with 3.3, the system shall be a 1-2 speed heat pump system. Variable capacity heat pumps are ineligible from claiming this option. d. This option may only be claimed if serving System Type 4 or 5 from Table R406.2. e. Primary living areas include living, dining, kitchen, family rooms, and similar areas. f. Option 3.10 may one be taken with Efficient Water Heating Option 5.1 or 5.2. Equipment sizing for space heating shall be calculated as provided in Section R403.7 with increased capacity to provide a minimum of 75 percent of peak hot water demand or shall be sized in accordance with approved manufacturer's specifications or guidance. Supplementary heat for water heating shall be in accordance with Section R403.5.7. i REGISTERED .4Rr-H I TEGT s� EMlr_H EL YNE .. OHNSON STATE OF WASHINGTON V W — 6 m � T z �tu0 U) W 0 2 VI Z (n V V1 l 1 V V1 n 1V �_ 0 N � DATE: 10-06-24 REVISIONS: DRAWN BY: MWJ C,HEGiGED BY: MWJ N — 5 16d ® 3" O.C. STAGGER 8d ® 6" O.C. 2x6 P.T. MUDSILL W/ A.B. FULL WIDTH 2x P.T. PER SHEARWALL SCHEDULE SHEATHING EDGE NAILING MUDSILL W/ A.B. 12" MIN. AT MUDSILL ENDS & TO EA. STUD, TYP. PER SHEARWALL SCHEDULE JOINTS, WITH 7" MIN. EMBED. W/ CONT. SHEATHING TO SILL 12" MIN. AT MUDSILL ENDS & 3"x3"x1 /4" PLATE WASHERS (2)2X6 AT HOLD—DOWN JOINTS, WITH 7" MIN. EMBED. W/ STHDRJ HOLDDOWN, FILL ALL 3"x3"x1/4" PLATE WASHERS FLOOR JOIST PER PLAN NAIL HOLES TO DBL. STUD AT STRAP LOCATION (PER PLAN) TOP FLANGE HANGER EDGE NAILING (OPT: GLUE JOIST IN HANGER PER S.W. SCHED. HANGER W/ TYP. SHEATHING 2x10 RIM BOARD ADHESIVE TO REDUCE o SQUEEKING NOT REQUIRED) Ld EDGE NAILING FLOOR JOIST PER PLAN PER S.W. SCHED. a b z m FINISH D0 GRADE w (2)LAYERS OF ° z X w Q 30# FELT BETWEEN Z WOOD AND CONIC. HOOK VERTICAL REBAR, I — � #4 CONT. � TOP J � � ALTERNATE SIDES a _ #4 ®24 OC co m v o HOOK VERTICAL REBAR, 6 MIL. BLACK I a III= VERT. @ CL OF WALL -1 1 z Q ALTERNATE SIDES POLY VAPOR BARRIER =III=III=TYP. � `"' =m � 6 MIL. BLACK I POLY VAPOR BARRIER UNYIELDING SOIL L- - co Q UNYIELDING SOIL III_ 77-77 4 HORIZ BARS- I - SHEATHING EDGE NAILING TO EA. STUD, TYP. CONT. SHEATHING TO SILL (2)2X6 AT HOLD—DOWN STHD HOLDDOWN, FILL ALL NAIL HOLES TO DBL. STUD AT STRAP LOCATION (PER PLAN) 16d @ 3" O.C., STAGGER 8d @ 6" O.C. w EDGE NAILING z PER S.W. SCHED. Q Ib OF - GRADE 00 z z m o' II �IIIII�iII' z Q °� °IIIIIII L)Ld #4 CONT. C� TOP J J � _ ='#4 0 24" OC m y L, 0� VERT. ®� OF WALL _ 1 Z Q Dm N I_TYP. I III —III- Q a 00 I=1 11- w w - — — - cn ® 10' O.C., TYP UNO (2)#4 T. BOTTOM4 HORIZ. BARS 3"I 61"- 3" (2)4 CUN 1. t3U l I UM GR. 40, TYP. C�? 10 O.C., TYP UNO GR_ 40_ TYP_ 1'-0" NOTE: FOR UNBLANCED BACKFILL ° a OF 2'-7" - 4'-0" USE ALTERNATE FOOTING DESIGN ° G d, a 4„ 8„ 4„ L L 'd .I Of 101 V-4" ALTERNATE FOOTING EXTERIOR SHEARWALL @ CRAWL— SPACE 3/4"=1'-0" 2x6 P.T. MUDSILL W/ A.B. PER SHEARWALL SCHEDULE 12" MIN. AT MUDSILL ENDS & JOINTS, WITH 7" MIN. EMBED. W/ 3"x3"x1/4" PLATE WASHERS #4 CONT. EXPANSION JOINT d d d . I I ; � I I I —III —III °d � • —III—III °.41.. #q4 0 24" O.C. VERT. ALT. HOOKS :III=III d.:d #4 0 10" O.C. HORZ. UN -YIELDING SOIL — JOISTS ON TOP OF STEM WALL \ PLY. EDGE NAILING HOLDOWN STUD (2)2x STUDS AT HOLD-DOWNS S D14 w7 38-2 1 / 2x .148 STRAP LOCATION o PER PLAN z EDGE NAILING FINIS a GRADE 0° z 7 D �fh I X o� Qz_J� ry 0 �III� -I 1= QY D' o I ZQ DIM =1 00 J a 3" 6» 3" w w v, .da. ° .d d° NOTE: FOR UNBLANCED BACKFILL 9' de 'A OF 2'-7" - 4'-0" USE ALTERNATE FOOTING DESIGN [4"[ 8" [4"[ 1'-4" ALTERNATE FOOTING EXT. SHEARWALL @ SLAB 3/4"=1'-0" EDGE NAILING PLYWOOD SPLICE PANEL EDGE NAILING PER SHEARWALL SCHEDULE 7/16" O.S.B. SHEAR PANEL PLATE NAILING PER SHEARWALL SCHEDULE 2x10 BLOCKING PLYWOOD SPLICE END TRUSS PER MANUFACTURER PLATE NAILING PER SHEARWALL SCHEDULE (MIN. 16d ® 6" O.C.) FOR SHEARWALL TYPE 4 USE A35F CLIP ® 12" O.C. TRUSS PARALLEL TO EXTERIOR WALL 3/4"=1 °-0" TRUI NOTE: FOR UNBLANCED BACKFILL a OF 2'-7" - 4'-0" USE a ALTERNATE FOOTING DESIGN a a 4„ 8„ 4„ 1'-4" ALTERNATE FOOTING EXTERIOR SHEARWALL @ CRAWL SPACE 3/4"=1'-0" PER PLAN SAVE @ ROOF 3 4 =1 —0 2x4 RIBBON SUPPLIED BY TRUSS MFR. (2) CS16 STRAP/ FILL ALL HOLES— w/ NAILS 00 2x4 RIBBON SUPPLIED - BY TRUSS MFR. JOISTS HANGING FROM STEM WALL SIMPSON H1 EA. END/ EA. TRUSS/ RAFTER PLY. EDGE NAILING 2x BLOCK w/ 1 1/2" REQUIRED w/ (2)16d T.N. EA. TRUSS/ EA. END EDGE NAILING 2x STUD 0 16" O.C. PLY. PER SCHEDULE (2)2x STUDS HOLDOWN TRUSS PER PLAN BLOCKING ATTACHED BY TRUSS MFR. SHEATHING FILLER PIECE (2)2x STUDS ® HOLDOWN STRAP HOLDOWN AT FLOOR 3/4"=1'-0" EXTENT OF HEADER WITH DOUBLE PORTAL FRAMES (TWO BRACED WALL PANELS) EXTENT OF HEADER WITH SINGLE PORTAL FRAME (ONE BRACED WALL PANEL) 2' to 18' R.O. WIDTH FOR SINGLE OR DOUBLE PORTAL HEI FASTEN SHT'G. TO HEADER w/ 8d COMMON OR GALVANIZED BOX NAILS Q 3"o.c. GRID PATTERN AS SHOWN HEADER TO JACK -STUD STRAP PER 1 WIND DESIGN. MIN. 1,0001b ON BOTH MAX. SIDES OF OPENING. INSTALL ON Z i8" O.S.B./PLYWOOD �0 AL OPPOSITE SIDE OF SHT'G. SHT'G. WALL 1 El 3,HT - MIN. DOUBLE 2x4 FRAMING COVERED M X. W/ 16" O.S.B./PLYWOOD SHT'G. w/ HEI HT 8d COMMON OR GALVANIZED BOX MIN. DOUBLE 2x4 NAILS @ 3"o.c. IN ALL FRAMING POST (KING & JACK (STUDS, BLOCKING, & SILLS), TYP. STUD). NUMBER OF JACK STUDS PER 16" MIN. LENGTH OF PANEL IRC TABLES R602.7(1) & (2) r i MIN. (2)3,5001b (STHD14) STRAP -TYPE •�r j• 7 HOLD DOWNS (EMBEDDED INTO h. x 4 CONCRETE & NAILED INTO FRAMING) MIN. 1,000Ib (STHD14) 4 w i . a' HOLD DOWN x (EMBEDDED INTO �• •r MIN. REINFORCING OF FOUNDATION, CONCRETE & NAILED _ Ot 10 (2)#4 BAR TOP & BOTT. OF FOOTING. INTO FRAMING) 01 01 d IV pl a LAP BARS 15" MIN. HOOK ENDS Q� °11' rp d np� Ml -' �`a a ° ° d MIN. (1)8"� ANCHOR BOLT MIN. FOOTING SIZE UNDER OPENING IS INSTALLED PER IRC R403.1.6 12"x12". A TURNED -DOWN SLAB SHALL A w/ 2%2"xi" PLATE WASHER BE PERMITTED @ DOOR OPENINGS. PAPA PORTAL —FRAME w/ HOLD DOWNS N.T.S. END OF PLATE P PLATE STUDS PANEL EDGE NAILING PER SHEARWALL SCHEDULE 2x10 RIM PLYWOOD SPLICE 2x4 RIM PANEL EDGE NAILING PER SHEARWALL SCHEDULE 7/16" O.S.B. SHEAR PANEL HEADER TO JACK -STUD STRAP PER WIND DESIGN. MIN. 1,0001b ON BOTH SIDES OF OPENING. INSTALL ON OPPOSITE SIDE OF SHT'G. FASTEN KING STUD TO HEADER w/ (6)16d SINKERS SHIM Q STRAP AS REQUIRED FASTEN TOP PLATE TO HEADER w/ (2)ROWS OF 16d SINKER NAILS O 3"o.c. TYP. TYP. PORTAL FRAME CONSTRUCTION PANEL SPLICE EDGES SHALL OCCUR o/ & BE NAILED TO COMMON 2x4 MIN. BLK'G. WITHIN MIDDLE 24" OF PORTAL -LEG HEIGHT. (1)ROW OF 8d ® 3"ox. NAILING IS REQUIRED IN EA. PANEL EDGE. BLK'G. TO STUDS w/ (2)8d TOE NAILS ® EA. END STRAP HOLD-DOWN MAY BE LOCATED ON THE BACKSIDE OF THE PORTAL -FRAME BRACING qqi @l5 d PLATE NAILING PER SHEARWALL SCHEDULE FLOOR SHEATHING o/ MANUFACTURED TRUSSES TRUSS PER PLAN TRUSS PERPENDICULAR TO EXT. WALL 3/4"=1'-0" NOTE: SPLICE AND NAIL TOP PLATES AS SHOWN ® ALL EXTERIOR EXTERIOR WALLS, SHEAR WALLS, & AT EACH FLOOR PLYWOOD LEVEL AND AT ROOF. ELEVATION 12d ® 4" O.C. 8d ® 6" O.C. DBL. TOP PLATE SPLICE SUBFLOOR EDGE NAIL 3 /4"=1'-0" PREMANUFACTURED FLOOR TRUSS PER PLAN SECTION 8d ® 6" O.C. SUBFLOOR_�'. D r(TYP-) �T 2x BLOCKING �12d ® 4" O.C. ` 1 3/4"XFULL DEPTH" LSL 7/16" PLY. SHEAR PANEL CONT. RIM OR BUILT-UP W/ 2x4 EACH SIDE EDGE NAIL 2X RIM PER TRUSS MFR. TIAO.S.B. STIFFNER w / 12d ®4" O.C. 7/16" O.S.B./ PLYWOOD NAIL PLY. w/ 8d 0 4" O.C. PER SCHEDULE (TYP.) 0 NAILING DETAIL @ CANT. FLOOR TRUSS (4)12d BLOCKING TO PLATES ® EA. PANEL DBL. 2x TOP PLATE ELEVATION 3/4" T&G PLYWOOD SUBFLOOR w/ EDGE NAILING TO BL PANEL 8d ® 6" O.C. ALL EDGES 7/16" O.S.B. STIFFNER w/ 8d ® 4" O.C. ALL EDGES 2x4 BLOCKING (4 SIDES) 12d ® 14" O.C. ALL ED, EDGE 2x4 STUDS ® 16" (3)16d TO PLA_ TYP. EACH PANEL SECTION 2021 IBC CODE VERSION SIMPSON (2)CS16 STRAPS ILL ALL HOLES W/ 8d NAILS PLYWOOD PER 8d ®4" OC EDGE NAIL PLY. TO STUD SCHEDULE TRUSS / DRAG STRUT DESIGN FOR z (2)2x STUDS PLYWOOD 240#/FT LATERAL .. z g ® HOLDOWN LOAD (1)2x STUDS - EDGE NAILING O EACH HOLDOWN 00 FLOOR PLYWOOD `J TRUSS PER PLAN .-. z EDGE NAIL A35 0 SIMPSON CS16 STRAP v 16" OC FILL HOLES W/ 8d PLYWOOD NAILS AS SHOWN PER SCHED y SHEARWALL PER PLAN PROVIDE (2) VERTICAL WEB MEMBERS @ EA. STRAP PARALLEL INT. SHEARWALL TO FLOOR ABV. �14..=1.-0. `BEAM PER PLAN STRAP HOLDOWN AT HDR 3/4"=1'-0" GIRDER TRUSS TO BE DESIGNED FOR-' 1600# x 2.5 OVERSIZE FACTOR UPLIFT & COMPRESSION PER EACH CS16 CALL -OUT HOLDDOWN (USE 1.6 LOAD DURATION) U.N.O. NOTE: AT EXTERIOR TRUSS TO WALL CONNECTION AT "SIM" P1 STRAP AT HOLDOWN AT TRUSS 3/4 =1 —0 U0) Z M� N rn 04 O V J j N ry > Q W CU C� W Y D- v Z Y N a� o r— V L_ uJ M im Z -v 00 W N N E M 00 N M Lu LL ~ J_ Q W 0 Q w CN ~ O Z z J U ti 00 O GO O Q O W H Z J - z �r N W Wo U) U 2 Q 00 O C� EXPIRES 2 2026 Project FlLE NUMBER DRAWN BY Date 7.15.2025 Sheet S1 2021 IBC CODE VERSION A35 CLIP TRUSS TO DBL. PLA 016"o. c. EDGE N DRAG STRUT TRUSS 3 4 =1'— 0 8d04"O.C. PLY. TO BLOCK - (2)2x6 BLOCK 0 6" O.C. Y. EDGE NAILING USS DRAG STRUT :R PLAN :SIGN FOR 200/# PER FT. 7ERAL LOAD .Y. PER SCHEDULE 16d PLYWOOD SUB—F PLYWOOD PER SCHEDULE — EDGE NAILING FLOOR GIRDER TRUSS OR BLOCKING DRAG STRUT FLOOR TRUSS UNDER SW 3/4"=1'-0" (6) 12d BRACE 2x TRUSSES 0 24" O.C. TO BLOCK 2x OUTRIGGER (OPTIONAL) EGDE NAILING ° ° ° ° - ° DBL. TOP CHORD ° HORZ. WEB BRACING BY ° ° ° ° 01 01 ° TRUSS MFGR. PER T.P.I. SPECS. NAIL TO ALL TRUSSES 12d 0 6" O.C. 1 �1 (2)2x6 CONT. 0 GABLEEND TRU MID HEIGHT ° ° ° ° STRUCTURAL TRUSS w/ 2x4 FLAT INLET STUDS 0 24" O.C. (2)A35 CLIPS X. (2)A35 CLIPS (ONE EA. SIDE) 2)2x6 DIAGONAL "T" QRACE 12d 0 6" O.C. (TRUSS TO 2x6) RIDGE AND 0 10'-0 O.C. MAX. (VERIFY w/ TRUSS MFGR.) 2x6 CONT. EDGE NAILING 12d 0 6" O.C. 2x6 CONT. TO TOP PLATE 7/16" O.S.B. OR 1/2" PLYWOOD T TYP. GABLE TRUSS DETAIL 3/4"=1'-0" EDGE NAIL PLY. TO EACH TRUSS ROOF TRUSS DESIGN FOR 200/# PER FT. LATERAL LOAD (4)12d TO 20 FLAT TO TOP PLATE 2x4 FLAT 0 12" O.C. (2)16d IEDULE ROOF TRUSS PARALLEL TO S.W. 3 /4"=1'-0" CONT. PLY ROOF TO F 8dO6"o.c. 16d04"o.c. A35 CLIPS ROOF PLY. EDGE NAILING MONO TRUSSES PER PLAN TRUSS HANGER 2x10 LEDGER PER PLAN w/(7) 16d016"c EDGE NAILING PLY PER PLAN 2xBLOCKING 2xSTUDS 0 16"o.c. 2x LEDGER w/(3) 16d016"o.c. 0 EA. 2x STUD (TYP.) TRUSS TO WALL CONNECTION JOIST AN IP 0 16"o.c. IS 0 16"o.c. H TT5 HOLDOWN ANCHOR FILL ALL HOLES w/ NAILS (2)2x STUDS EDGE NAILING PLY. TO EACH DOUBLE STUD 5_ /8" DIA. THREADED ROD I SIMPSON EPDXY- TIE 22 ADHESIVE SYSTEM OR EQUIVALENT PER MFGR. RECOMMENDATION CONIC. FOUNDATION TYP. HOLDOWN TO EXISTING FOOTING 3/4"=1'-0" TO BE USED IN CASE OF A MISPLACED HOLD—DOWN 2x F.J'S PER PLAN 2x BLKG W/ 16d LAPE 6" W/ (4) 16d TOE NAILS 0 6" O.C.\ 1 F FACENAILS + + + + 20 CLEAT EA. SIDE z SIMPSON A35 TWO SIDES PT 40 POST z PT 46 0 BM. SPLICE _ FOOTING AND REBAR PER PLAN PER PLAN o a I ° �.°.. A ,a ° G CC POST PAD CON-NECTION 2x STUD, TYP. 2x4 STUD 20 STUD J W NAILING, TYP. PLAN VIE CORNER DETAIL DOUBLE TOP PLATE SEE SCHEDULE FOR CRIPPLE & KING STUD I INFORMATION (4)16d ' SNUG FIT (2)16d TOES —All, 16d 0 12" O.C. (2) 2x TOP PLATE, U.N.O 2x CRIPPLE PER SCHED. (2)16d I I EA. STUD (1) 2x 8'-0" MAX I 2 2x OVER 8'-0" 2x CRIPPLE STUDS 0 16" O.C. WHERE HEADER IS NOT TIGHT I TO PLATE SILL WHEN I I I (2)16d TOENAIL APPLICABLE I I I I TOP & BOTTOM (2) 2x HEADER OR BEAM SIZER PER PLAN 2 ROWS OF 16d NAILS 0 8" O.C. ALTERNATE NAILING FORM EACH SIDE 7/16" OSB SPACER R-10 RIGID INSULATION (PER ARCH) BUILT-UP HEADER 3"=1'-0" BEARING OPENING WALL OPENING FRAMING SCHEDULE (UNO ON PLAN) WIDTH OF OPENING CRIPPLES KINGS COMMENTS SILL 0 — 4'-0" MAX. 1 1 (4)16d EA. KING STUD TO HDR. 4'-1"— 5'-6" MAX. 2 1 (4)16d EA. KING STUD TO HDR. 5'-7" — 8-0" MAX. 2 2 (4)16d EA. KING STUD TO HDR. & (1)LTP4 HDR TO EA. KING STUD 8'-1" & OVER SEE PLANS SEE PLANS SEE PLANS 16d 0 6" D.C. RUSS PER LAN ALA OP HEARWALL PER CHEDULE TRUSS .W1 2x4 EA. -,SID NAIL W/ 16 06 o.c. TO EA. TRUSS (TYPICAL SHEAR PANEL @ SH EARWALLS NOTE: TRUSS BLOCKING MAY BE SUBSTITUTED FOR SHEAR PANELS W/ (2)LTP4 @ 12" O.C. T.P. INTERIOR NON —BEARING OPENING (NOT AT GARAGE TO HOUSE MAN DOOR) NOTES: 1. ALL HEADERS PER PLAN 2. PROVIDE (2)2x6 HDR. 0 BEARING OPENINGS & BELOW STRUCTURAL GIRDER END TRUSSES 3. SEE PLANS FOR INFORMATION NOT NOTES WALL OPENING DETAIL U Z M� N 0) N 0 V J j N Iyf. > Q W ca X "�1 w Y ILLV Z Y N ai 0) N O � r� V �M LL Z -o 00 � W N " `� N E M W N M �W LL ~ ti 00 O GO cl 0 W H Z J - z N w Wo w U 2 U) M� w O EXPIRES 2 2026 Project FlLE NUMBER DRAWN BY Date 7.15.2025 Sheet S2 (TYPICAL) E GENERAL STRUCTURAL NOTES (The following applies unless specifically indicated otherwise on the plans.) ox w 1. ALL MATERIALS & WORKMANSHIP, DESIGN, & CONSTRUCTION SHALL CONFIRM TO THE REQUIREMENTS OF THE DRAWING SPECIFICATIONS, THE INTERNATIONAL BUILDING CODE, 2021 EDITION. 2. DESIGN CRITERIA ROOF LIVE LOAD (SNOW) 25 psf PHOTOVOLTAIC PANEL SYSTEM 4 psf & 175 lb INVERTER LOAD ON 4 SQFT EVERY 1000 SQFT SPRINKLERS 1.5 psf (IF APPLICABLE) FLOOR LIVE LOAD (RESIDENTIAL) 40 psf FLOOR LIVE LOAD (DECK) 60 psf (1.5x AREA SERVED) HANDRAILS & GUARDS RAIL LINE LOAD: 50 psf RAIL CONCENTRATE LOAD: 200# STAIR & CORRIDOR LIVE LOAD 100 psf MECHANICAL UNITS WEIGHTS AS FURNISHED BY MFG. WIND 100mph (BASIC WIND SPEED) EXPOSURE 'B' (RISK CATEGORY II) Kzt = 1.2 EARTHQUAKE SS=1.60 Sl =.57 (CLASS 'D') LIGHT FRAMED SHEAR WALL R=6.5 ALLOWABLE SOIL PRESSURE 2,000 psf. (NATURAL SOILS or COMPACTED) SEE PLANS & COMPUTATIONS FOR ADDITIONAL LOADING CRITERIA PER I.B.C. SECTION 1605-1609. 3. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION w/ ARCHITECTURAL DRAWINGS FOR BIDDING CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS & CONDITIONS FOR COMPATIBILITY & SHALL NOTIFY THE ARCHITECT & STRUCTURAL ENGINEER, OF ANY DISCREPANCIES PRIOR TO CONSTRUCTION TO ALLOW ARCHITECT & ENGINEER TO COMPLETE PROPER REVISIONS TO THE WORK. 4. DEMOLITION: CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS BEFORE COMMENCING ANY DEMOLITION. SHORING SHALL BE INSTALLED TO SUPPORT EXISTING CONSTRUCTION AS REQUIRED & IN A MANNER SUITABLE TO THE WORK SEQUENCES. DEMOLITION DEBRIS SHALL NOT BE ALLOWED TO DAMAGE OR OVERLOAD THE EXISTING STRUCTURE. LIMIT CONSTRUCTION LOADING (INCLUDING DEMOLITION DEBRIS) ON EXISTING FLOOR SYSTEMS TO 40 psf. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES, & CONDITIONS PRIOR TO COMMENCING ANY WORK, ALL DIMENSIONS OF EXISTING (e) CONSTRUCTION SHOWN ON THE DRAWINGS ARE INTENDED AS GUIDELINES ONLY & MUST BE FIELD VERIFIED. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING & SHORING FOR THE STRUCTURE & STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE PLANS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REQUIRED SAFETY PRECAUTIONS & THE METHODS, TECHNIQUES, SEQUENCES & PROCEDURES REQUIRED TO PERFORM HIS WORK. 7. CONTRACTOR -INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE ARCHITECT & THE STRUCTURAL ENGINEER FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWINGS ONLY WILL NOT SATISFY THIS REQUIREMENT. 8. DRAWINGS INDICATE GENERAL & TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED, SUBJECT TO REVIEW & APPROVAL BY THE ARCHITECT & STRUCTURAL ENGINEER. 9. ALL STRUCTURAL SYSTEMS WHICH ARE TO BE COMPOSED OF COMPONENTS TO BE FIELD ERECTED, SHALL BE SUPERVISED BY THE SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE & ERECTION IN ACCORDANCE WITH INSTRUCTIONS PREPARED BY THE SUPPLIER. 10. SHOP DRAWINGS FOR STRUCTURAL STEEL, GLUED LAMINATED MEMBERS, OPEN WEB WOOD TRUSSES, & PLYWOOD WEB JOISTS SHALL BE SUBMITTED TO THE ARCHITECT & STRUCTURAL ENGINEER FOR REVIEW TWO WEEKS PRIOR TO FABRICATION OF THESE ITEMS. 11. SHOP DRAWINGS REVIEW: DIMENSIONS & QUANTITIES ARE NOT REVIEWED BY THE ENGINEER OF RECORD, & THEREFORE MUST BE VERIFIED BY THE CONTRACTOR. CONTRACTOR SHALL REVIEW & STAMP DRAWINGS PRIOR TO REVIEW BY ENGINEER OF RECORD. SUBMISSIONS SHALL INCLUDE A REPRODUCIBLE & ONE COPY; REPRODUCIBLE WILL BE MARKED & RETURNED. SHOP DRAWINGS SUBMITTALS PROCESSED BY THE ENGINEER ARE NOT CHANGE ORDERS. THE PURPOSE OF SHOP DRAWING SUBMITTALS BY THE CONTRACTOR IS TO DEMONSTRATE TO THE ENGINEER THAT THE CONTRACTOR UNDERSTANDS THE DESIGN CONCEPT, THAT HE DEMONSTRATES HIS UNDERSTANDING BY INDICATING WHICH MATERIAL HE INTENDS TO FURNISH & INSTALL & BY DETAILING THE FABRICATION & INSTALLATION METHODS HE INTENDS TO USE. IF DEVIATIONS, DISCREPANCIES, OR CONFLICTS BETWEEN SHOP DRAWING SUBMITTALS & THE CONTRACT DOCUMENTS ARE DISCOVERED EITHER PRIOR TO OR AFTER SHOP DRAWING SUBMITTALS ARE PROCESSED BY THE ENGINEER, THE DESIGN DRAWINGS & SPECIFICATIONS SHALL CONTROL & SHALL BE FOLLOWED. GEOTECHNICAL 12. FOUNDATION NOTES: SUB -GRADE PREPARATION INCLUDING DRAINAGE, EXCAVATION, COMPACTION, & FILLING REQUIREMENTS, SHALL CONFORM STRICTLY WITH RECOMMENDATIONS GIVEN IN THE SOILS REPORT FOOTINGS SHALL BEAR ON SOLID UNDISTURBED EARTH (CONTROLLED, COMPACTED STRUCTURAL FILL or BOTH) AT LEAST 18" BELOW LOWEST ADJACENT FINISHED GRADE. FOOTING DEPTHS/ELEVATIONS SHOWN ON PLANS (or IN DETAILS) ARE MINIMUM & FOR GUIDANCE ONLY; THE ACTUAL ELEVATIONS OF FOOTINGS MUST BE ESTABLISHED BY THE CONTRACTOR IN THE FIELD WORKING WITH THE TESTING LAB & SOILS ENGINEER. BACKFILL BEHIND ALL RETAINING WALLS WITH FREE DRAINING GRANULAR FILL & PROVIDE FOR SUBSURFACE DRAINAGE. STRUCTURAL FILL: AS APPLICABLE PER SITE CONDITIONS OR AS DIRECTED BY THE SOILS ENGINEER. FOLLOW ALL RECOMMENDATIONS & SPECIFICATIONS AS GIVEN PER THE SOILS REPORT. CONCRETE 13. CONCRETE SHALL ATTAIN A 28 DAY STRENGTH OF f c= 2,500 psi & MIX SHALL CONTAIN NOT LESS THAN 5 1/2 SACKS OF CEMENT PER CUBIC YARD & NO MORE THAN 6 GALLONS OF WATER PER SACK OF CEMENT. ALL CONCRETE EXPOSED TO WEATHER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINING AGENT CONFORMING TO I.B.C. THE AMOUNT SHALL BE 47o + 1% BY VOLUME. fc = 3,000 psi. 14. REINFORCING STEEL SHALL CONFORM TO ASTM A615, (INCLUDING SUPPLEMENT S1) GRADE 60, fy = 60,000 psi. EXCEPTION: COLUMN TIES, BEAM STIRRUPS, BARS TO BE FIELD BENT, BARS TO BE WELDED & ANY OTHER BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, fy = 40,000 psi REINFORCING COMPLYING WITH ASTM A706 (S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN A.W.S. D1.4 ARE SUBMITTED. NO REINFORCING SHALL BE WET -SET UNLESS SPECIFICALLY SO DETAILED. WELDED WIRE MESH SHALL CONFORM TO ASTM A-185. 15. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS & BENDS) IN ACCORDANCE WITH ACI 318-19. LAP ALL CONTINUOUS REINFORCEMENT 58 BAR DIAMETERS (2'-6" min.). PROVIDE CORNER BARS AT ALL WALL INTERSECTIONS. LAP CORNER BARS 30 BAR DIAMETERS (2'-6" min.). LAP ADJACENT MATS OF WELDED WIRE FABRIC TWO SQUARES (min. OF 12") AT SIDES & ENDS. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE STRUCTURAL ENGINEER. 16. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: FOOTINGS & OTHER UNFORMED SURFACES, EARTH FACE 3" FORMED SURFACES EXPOSED TO EARTH (i.e. WALLS BELOW GROUND) OR WEATHER #6 BARS OR LARGER 2" #5 BARS OR SMALLER 1 1/2" COLUMN TIES OR SPIRAL & BEAM STIRRUPS 1 1/2" SLABS & WALLS (INTERIOR FACE) 3/4- CAST-IN-PLACE CONCRETE: SEE ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS & DIMENSIONS OF DOOR & WINDOW OPENINGS IN ALL CONCRETE WALLS. SEE MECHANICAL DRAWINGS FOR SIZE & LOCATION OF MISCELLANEOUS MECHANICAL OPENINGS THROUGH CONCRETE WALLS, SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, & OTHER FINISH DETAILS AT ALL EXPOSED CONCRETE SURFACES, BOTH CAST -IN -PLACE & PRECAST. 17. NON -SHRINK GROUT (3,000psi MINIMUM STRENGTH) SHALL BE FURNISHED BY AN APPROVED MANUFACTURER & SHALL BE MIXED & PLACED IN STRICT ACCORDANCE WITH THE MANUFACTURE'S PUBLISHED RECOMMENDATIONS. CTl�_ �_I 18. STRUCTURAL STEEL DESIGN, FABRICATION, & ERECTION SHALL BE BASED ON ON THE A.I.S.C. "SPECIFICATION FOR THE DESIGN, FABRICATION, & ERECTION OF STRUCTURAL STEEL BUILDINGS", LATEST EDITION, PLUS ALL REFERENCES CODES. 19. STRUCTURAL WIDE FLANGE SHAPES TO CONFORM TO ASTM A992, Fy = 50 ks OTHER STRUCTURAL STEEL INCLUDING PLATES SHALL CONFORM TO ASTM A36, Fy = 36 ksi STEEL PIPE SHALL CONFORM TO ASTM A-53, TYPE E, OR S, GRADE B, Fy = 35 ksi STRUCTURAL TUBING SHALL CONFORM TO ASTM A500, Fy = 46 ksm BOLTS SHALL CONFORM TO ASTM A307 (CONNECTION BOLTS A325-N) EXPANSION SHALL BE "PARABOLT" or APPROVED EQUAL INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURES'S PUBLISHED RECOMMENDATION. EXPANSION BOLTS SHALL ALSO BE SIMPSON STRONG BOLT INSTALLED PER ICC-ESR REQUIREMENTS OR EQUAL. 20, ALL WELDING SHALL BE IN CONFORMANCE WITH A.I.S.C. & A.W.S. STANDARDS & SHALL BE PERFORMED BY W.A.B.O. CERTIFIED WELDERS USING E70XX ELECTRODES, ONLY PRE -QUALIFIED WELDS (AS DEFINED BY A.W.S.) SHALL BE USED, WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E70XX ELETRODES & PER ASTM A706. WELDING WITHIN 4" OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS. STEEL FABRICATION GENERAL: ALL WELDING IS REQUIRED TO BE DONE BY A WABO CERTIFIED WELDER & HAVE SPECIAL INSPECTIONS BY WABO CERTIFIED INSPECTION AGENCY, OR BE DONE IN A WABO CERTIFIED FABRICATION SHOP. HAVE EITHER THE SPECIAL INSPECTION REPORT OR WABO FABRICATION SHOP CERTIFICATION AVAILABLE ON SITE FOR THE BUILDING INSPECTOR. 21. WELDING: 1) WELDING SHALL CONFIRM TO AWS D1.1 & VISUALLY CONFIRM TO AWS SECTION 6 & TABLE 6.1. FABRICATION/ERECTION INSPECTIONS BY THE CONTRACTOR PER AWS D1.1 SECTION 6, SHALL BE BY ASSOCIATE/CERTIFIED INSPECTORS (AWI/CWI) PER AWS QC1 OR AWS B5.1. SPECIAL INSPECTIONS (VERIFICATION INSPECTIONS SHALL BE BY A CERTIFIED WELDING INSPECTOR (WI) OR SENIOR WELDING INSPECTOR (SWI) PER AWS B5.1 2) WELDERS SHALL BE QUALIFIED FOR THE SPECIFIC PRE -QUALIFIED JOINTS REQUIRED BY THE DESIGN & CERTIFIED IN ACCORDANCE WITH WABO REQUIREMENTS. 3) WELDING SHALL BE DONE IN ACCORDANCE WITH APPROPRIATE WELD PROCEDURE SPECIFICATIONS (WPS's). WELDERS SHALL BE FAMILIAR WITH THE APPLICABLE WPS's. 4) WELDING SHALL BE DONE WITH AWS PRE -QUALIFIED WELDING PROCESSES UNLESS OTHERWISE APPROVED. 5) WELDER QUALIFICATIONS & WPS's SHALL BE MAINTAINED AT THE SITE OF THE WORK & SHALL BE READILY AVAILABLE FOR INSPECTION UPON REQUEST, BOTH IN THE SHOP & IN THE FIELD. 6) USE E70 OR E71 T, 70ksi STRENGTH ELECTRODES APPROPRIATE FOR THE PROCESS SELECTED. 22. FABRICATION: 1) CONFORM TO AISC 303, SECTION 8 & AISC 360 SECTION M2 & M5. 2) STRUCTURAL WELDING & QUALIFICATIONS SHALL CONFORM TO THE AWS D1.1 23. VERIFICATION INSPECTION: 1) STRUCTURAL WELDING INSPECTIONS & QUALIFICATIONS SHALL CONFIRM TO THE AWS D1.1. SEE WELDING NOTES & SPECIAL INSPECTIONS FOR STRUCTURAL STEEL. 2) SPECIAL INSPECTOR SHALL REVIEW THE PROCEDURES FOR COMPLETENESS & ADEQUACY RELATIVE TO THE CODE & THE WORK. FURTHER SHOP SPECIAL INSPECTIONS MAY BE WAIVED IF THE FABRICATOR IS "AISC CERTIFIED" OR OTHERWISE "APPROVED" BY THE AUTHORITY HAVING JURISDICTION PER IBC SECTION 1704.2.2 SEE SPECIAL INSPECTIONS FOR STRUCTURAL STEEL. 24. ERECTION: 1) CONFIRM TO AISC 303, SECTION 7 "ERECTION", SECTION 8 "QUALITY ASSURANCE." & AISC 360, SECTION M4. 2) THE ERECTOR SHALL MAINTAIN DETAILED FABRICATION & ERECTION QUALITY CONTROL PROCEDURES THAT ENSURE THAT THE WORK IS PERFORMED IN ACCORDANCE WITH AISC 360 SECTION M, AISC 303, & THE CONTRACT DOCUMENTS. 3) STEEL WORK SHALL BE CARRIED UP TRUE & PLUMB WITHIN THE LIMITS DEFINED IN AISC 303, SECTION 7.13. 4) STRUCTURAL WELDING TO CONFORM TO THE AWS D1.1 & APPLICABLE WELDING NOTES ABOVE. 5) SPECIAL INSPECTOR SHALL INSPECT THE STEEL FRAMING TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN ON THE CONTRACT DOCUMENTS INCLUDING MEMBER SIZE, LOCATION, BRACING & THE APPLICATION OF PROPER JOINT DETAILS AT EACH CONNECTION. 25. BRACING & SAFETY PROTECTION: THE CONTRACTOR SHALL PROVIDE TEMPORARY BRACING & SAFETY PROTECTION REQUIRED BY AISC 360 SECTION M4.2 & AISC 303 SECTION 7010 & 7.11. 26. PROTECTIVE COATING REQUIREMENTS: 1) SHOP PAINTING: CONFORM TO AISC 360 SECTION M3 & AISC 303 SECTION 6.5 UNLESS A MULTI -COAT SYSTEM IS REQUIRED PER THE PROJECT SPECIFICATIONS. 2) INTERIOR STEEL: a. UNLESS NOTED OTHERWISE, DO NOT PAINT STEEL SURFACES TO BE, 1. WELDED; IF AREA REQUIRES PAINTING, DO NOT PAINT UNTIL AFTER WELD INSPECTION & NON-DESTRUCTIVE TESTING REQUIREMENTS, IF ANY, ARE SATISFIED. b. INTERIOR STEEL, EXPOSED TO VIEW, SHALL BE PAINTED WITH ONE COAT OF SHOP PRIMER UNLESS OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. FIELD TOUCH-UPS TO MATCH THE FINISH COAT OR AS OTHERWISE INDICATED IN THE PROJECT SPECIFICATIONS. AlTraffaffirs 27. FRAMING LUMBER SHALL BE KILN DRIED OR MC-15 (MC-192), & GRADED & MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 16 (172), LATEST EDITION. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS (2x MEMBERS) HEM -FIR #2 BEAMS & STRINGERS DOUGLAS FIR #1 POSTS & TIMBERS DOUGLAS FIR #1 STUDS, PLATES & MISC. LIGHT FRAMING DOUGLAS FIR or HIM -FIR STAND. GRADE TOP & BOTTOM PLATES @ BEARING & SHEAR WALLS DOUGLAS FIR #2 or CONST. GRADE BOLTED STUDS, LEDGERS & PLATES HEM -FIR #2 or CONST. GRADE 2 2x6 STUDS HEM -FIR #2 or HEM -FIR CONST. GRADE 2 28. GLUE -LAMINATED MEMBERS SHALL BEAR AN AITC IDENTIFICATION MARK & SHALL BE ACCOMPANIED BY AN AITC CERTIFICATION OF CONFORMANCE. ALL SIMPLE SPAN BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V4, Fb= 2,400 psi, Fv = 240 psi. ALL CONT. & CANTILEVER BEAMS SHALL BE DOUGLAS FIR COMBINATION 24F-V8, Fb = 2,400 psi, Fv = 240 psi. 29. LAMINATED VENEER LUMBER SHALL BE FABRICATED IN CONFORMANCE WITH ICC-ES ESR-1387. EACH MEMBER SHALL BEAR AN IDENTIFICATION MARK. ALL BEAMS SHALL BE WESTERN SPECIES, GRADE 1.8E, Fb = 2,600 psi, Fv = 285 psi. 30. LAMINATED STRAND LUMBER (TIMBERSTRAND LSL) SHALL BE FABRICATED IN CONFORMANCE WITH CODE EVALUATION ICC ES ESR-1387. EACH MEMBER SHALL BEAR AN IDENTIFICATION MARK. ALL BEAMS SHALL BE WESTERN SPECIES, GRADE 1.55E, Fb = 2,325 psi, Fv = 310 psi. 31. PARALLEL STRAND LUMBER SHALL BE FABRICATED IN CONFORMANCE WITH ICC-ES ESR-1387. EACH MEMBER SHALL BEAR AN IDENTIFICATION MARK. ALL BEAMS SHALL BE DOUGLAS FIR, GRADE 2.OE, Fb = 2,900 psi, Fv = 290 psi 32. [DEFERRED SUBMITTAL:] PREFABRICATED OPEN WEB WOOD TRUSSES (or COMBINATION WOOD & METAL) SHALL BE DESIGNED BY THE MANUFACTURER FOR THE SPANS & CONDITIONS SHOWN ON THE PLANS & SHALL BE FURNISHED & INSTALLED IN CONFORMANCE WITH THE MANUFACTURER'S PUBLISHED SPECIFICATIONS. ALL NECESSARY BRACING, BRIDGING, BLOCKING, PRE -NOTCHED PLATES ETC., SHALL BE DETAILED & FURNISHED BY THE MANUFACTURER. SUBMIT SHOP DRAWINGS & DESIGN CALCULATIONS (COMPLETE WITH STRESS DIAGRAMS) TO THE ARCHITECT & THE STRUCTURAL ENGINEER FOR REVIEW TWO WEEKS PRIOR TO FABRICATION. DESIGN SUBMITTALS SHALL BEAR THE STAMP OF A REGISTERED PROFESSIONAL ENGINEER, STATE OF WASHINGTON. PERMANENT & TEMPORARY BRIDGING & BRACING SHALL BE INSTALLED IN CONFORMANCE WITH MANUFACTURER'S SPECIFICATIONS. 33. PLYWOOD SHEATHING SHALL BE GRADE C-D EXTERIOR GLUE or STRUCTURAL II, EXTERIOR GLUE ORIENTED STRAND BOARD OF EQUIVALENT THICKNESS, EXPOSURE 1 RATING & PANEL INDEX MAY BE USED IN LIEU OF PLYWOOD. SEE PLANS FOR THICKNESS, PANEL IDENTIFICATION INDEX & NAILING REQUIREMENTS. STRUCTURAL WOOD SHEATHING PANELS SHALL HAVE APA GRADE TRADEMARK OF THE AMERICAN PLYWOOD ASSOCIATION. 34. ALL WOOD PLATES & BLOCKING IN DIRECT CONTACT WITH CONCRETE OR MASONRY SHALL BE PRESSURE -TREATED WITH AN A.W.P.A. APPROVED PRESERVATIVE. PROVIDE 2-LAYERS OF ASPHALT IMPREGNATED BUILDING PAPER BETWEEN UNTREATED LEDGERS, BLOCKING, ETC., & CONCRETE OR MASONRY, 35. TIMBER CONNECTORS CALLED OUT BY LETTERS & NUMBERS SHALL BE BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG. EQUIVALENT DEVICES BY OTHER MANUFACTURERS MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC APPROVAL FOR EQUAL or GREATER LOAD CAPACITIES. PROVIDE NUMBER & SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. WHERE CONNECTORS STRAPS CONNECT TWO MEMBERS, PLACE HALF OF THE NAILS or BOLTS IN EACH MEMBER. ALL BOLTS IN WOOD MEMBERS SHALL CONFORM TO ASTM A307. PROVIDE WASHERS UNDER THE HEADS & NUTS OF ALL BOLTS & LAG SCREWS BEARING ON WOOD UNLESS NOTED OTHERWISE. ALL NAILS SHALL BE COMMON. ALL SHIMS SHALL BE SEASONED & DRIED & THE SAME GRADE (MINIMUM) AS MEMBERS CONNECTED. ALL JOISTS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS. ALL DOUBLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS. ALL TRIPLE JOIST BEAMS SHALL BE CONNECTED TO FLUSH BEAMS WITH "U" SERIES HANGERS. TJI JOIST HANGERS PER MANUFACTURER TJI SHOP DRAWINGS (U.N.O.) 36. PROTECTION OF CONNECTORS IN CONTACT WITH PRESSURE TREATED WOOD ALL BOLTS, NAILS, JOIST HANGERS & ANY OTHER CONNECTORS SHALL BE HOT DIPPED GALVANIZED FASTENERS RECOMMENDED TO CONFORM WITH ASTM STANDARD A-153 & HOT DIPPED GALVANIZED CONNECTORS SHOULD CONFORM TO ASTM A165, CLASS G-183. STAINLESS STEEL FASTENERS & CONNECTORS SHOULD BE TYPE 304 OF 316 SIMPSON PRODUCT FINISHES CORRESPONDING TO THESE REQUIREMENTS ARE ZMAX 9158 (HOT DIPPED GALVANIZED) & SST3000 (STAINLESS STEEL). 37. ALL WOOD FRAMING DETAILS - THE FOLLOWING APPLY UNLESS OTHERWISE SHOWN ON THE PLANS. A. MINIMUM NAILING REQUIREMENTS: UNLESS OTHERWISE NOTED, MINIMUM NAILING SHALL BE IN ACCORDANCE WITH TABLE 2304,10.1 OF THE INTERNATIONAL BUILDING CODE. B. AT SAWN TIMBER JOIST AREAS: PROVIDE CROSS -BRIDGING @ 8'-0"o.c. max. SPACING & SOLID BLOCKING AT BEARING POINTS, PROVIDE DOUBLE JOISTS UNDER ALL PARTITIONS. PROVIDE DOUBLE JOISTS EACH SIDE OF OPENINGS UNLESS DETAILED OTHERWISE. C. PROVIDE DOUBLE JOIST UNDER ALL PARALLEL PARTITIONS THAT EXTEND MORE THAN HALF THE JOIST LENGTH & DOUBLE JOIST HEADERS & DOUBLE JOISTS EACH SIDE OF ALL OPENINGS IN FLOORS & ROOFS UNLESS DETAILED OTHERWISE. COORDINATE SIZE & LOCATION OF ALL OPENINGS WITH ARCHITECTURAL & MECHANICAL DRAWINGS. D. PROVIDE TWO 2x10 HEADERS OVER & DOUBLE STUDS EACH SIDE OF ALL OPENINGS IN STUD BEARING WALLS NOT DETAILED OTHERWISE, E. PROVIDE SOLID BLOCKING FOR WOOD COLUMNS & MULTIPLE STUD POSTS THROUGH FLOORS TO SUPPORTS BELOW. F. PROVIDE CONTINUOUS SOLID BLOCKING AT MID OF ALL STUDS OVER 10' IN HEIGHT. G. TOENAIL JOISTS TO SUPPORTS WITH 2-16d NAILS. ATTACH ALL BEAMS AT THE ROOF EXCEEDING 8'-0" IN LENGTH TO SUPPORTS WITH ST22 STRAP EACH END. H. ATTACH TIMBER JOISTS TO FLUSH HEADERS AND BEAMS WITH "U" SERIES METAL JOIST HANGERS TO SUIT THE JOIST SIZE I. WALL FRAMING ALL STUD WALL SHOWN & NOT OTHERWISE NOTED SHALL BE 2x4 STUDS @ 16"o.c. AT INTERIOR WALLS & 2x6 STUDS @ 16" o.c. AT EXTERIOR WALLS. J. NOTATIONS ON DRAWINGS RELATING TO FRAMING CLIPS, JOIST HANGERS, & OTHER CONNECTING DEVICES REFER TO CATALOG NUMBERS OF CONNECTORS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY OR EQUIVALENT DEVICES BY OTHER MANUFACTURES MAY BE SUBSTITUTED, PROVIDED THEY HAVE ICC-ES APPROVAL FOR EQUAL LOAD CAPACITIES. K. INDIVIDUAL MEMBERS OF BUILT-UP POSTS & BEAMS SHALL EACH BE ATTACHED WITH 16d NAILS @ 6"o.c. STAGGERED. L. ALL WOOD STUDS WALLS SHALL HAVE LOWER WOOD PLATE ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS @ 6" o.c. STAGGERED UNLESS SHOWN OTHERWISE. M. ALL WOOD FRAMING DETAILS NOT SHOWN OTHERWISE SHALL BE CONSTRUCTED TO MINIMUM STANDARDS OF THE INTERNATIONAL BUILDING CODE. N. PLYWOOD ROOF SHEATHING & FLOOR SHEATHING UNLESS OTHERWISE NOTED ON PLANS SHALL BE LAID UP WITH FACE GRAIN PERPENDICULAR TO SUPPORTS & NAILED WITH 8d NAILS @ 6" o.c. TO FRAMED PANEL EDGES & OVER STUD WALLS SHOWN ON PLANS & @ 12"o.c. (10"o.c. AT FLOORS TO INTERMEDIATE SUPPORTS. PROVIDE APPROVED EDGE CLIPS @ 16"o.c. AT UNBLOCKED ROOF SHEATHING EDGES. PROVIDE SOLD BLOCKING AT LINES OF SUPPORT AT FLOORS. TOENAIL BLOCKING TO SUPPORTS WITH 16d NAILS @ 12"o.c. UNLESS OTHERWISE NOTED IN THE SHEAR WALL SCHEDULE. 0. PLYWOOD WALL SHEATHING SHALL HAVE SOLID BLOCKING AT ALL EDGES. P. ALL WOOD STUD WALLS SHALL HAVE LOWER WOOD PLATE ATTACHED TO WOOD FRAMING BELOW WITH 16d NAILS AT 6"o.c. STAGGERED or BOLTED TO CONCRETE WITH 5/8" DIA. ANCHOR BOLTS @ 4'-0"o.c. UNLESS SHOWN OTHERWISE. Q. PLYWOOD NAILING: (USE UNLESS GREATER NAILING IS DETAILED OR SPECIFIED) 8d @ 6"o.c. AT SHEET EDGES 8d @ 6"o.c. AT INTERMEDIATE BEARING POINTS R. 1. PROVIDE ABU POST BASE @ ISOLATED POSTS TO CONCRETE CONNECTION 2. PROVIDE (2)A35 CLIPS @ TOP & BOTTOM OF ALL POST TO OTHER FRAMING MEMBERS 3. PROVIDE AC or ACE POST CAP @ ISOLATED POSTS TO BEAM CONNECTIONS 4. PROVIDE MIN. (2)A35 CLIPS @ POST TO BEAM CONNECTION (U.N.O.) S. PROVIDE (2)CS16 x 36" AT ALL CUT DOUBLE TOP PLATE, TYP. T. ANCHORAGE: EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "SET-XP" HIGH STRENGTH EPDXY AS MANUFACTURED BY THE SIMPSON STRONG -TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH ICC-ES REPORT NO. ESR-2508. MINIMUM BASE MATERIAL TEMPERATURE IS 507. RODS SHALL BE ASTM A-36 UNLESS OTHERWISE NOTED. PERIODIC SPECIAL INSPECTION OF INSTALLATION IS REQUIRED TO VERIFY ANCHOR OR EMBEDDED BAR TYPE & DIMENSIONS, LOCATION, ADHESIVE IDENTIFICATION & EXPIRATION, HOLE DIMENSIONS, HOLE CLEANING PROCEDURE, ANCHOR EMBEDMENT & ADHERENCE TO THE INSTALLATION INSTRUCTIONS. CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR HORIZONTAL & OVERHEAD INSTALLATIONS. EPDXY -GROUTED ITEMS (THREADED RODS OR REINFORCING BAR) SPECIFIED ON THE DRAWINGS SHALL BE INSTALLED USING "AT-XP" AS MANUFACTURED BY SIMPSON STRONG -TIE COMPANY. INSTALL IN STRICT ACCORDANCE WITH IAMPO REPORT NO. ER-0281. MINIMUM BASE MATERIAL TEMPERATURE IS 14'F. RODS SHALL BE ASTM A-36 UNLESS OTHERWISE NOTED. PERIODIC SPECIAL INSPECTION OF INSTALLATION IS REQUIRED TO VERIFY ANCHOR OR EMBEDDED BAR TYPE & DIMENSIONS, LOCATIONS, ADHESIVE IDENTIFICATIONS & EXPIRATION, HOLE DIMENSIONS, HOLE CLEANING PROCEDURE, ANCHOR EMBEDMENT, & ADHERENCE TO THE INSTALLATION INSTRUCTIONS. CONTINUOUS SPECIAL INSPECTION IS REQUIRED FOR HORIZONTAL & OVERHEAD INSTALLATIONS. 2021 IBC CODE VERSION d Z M~ co _CD rn N 1 2 O 04 0 J N Q W W ALL@ Z Y04 0 rn N M W 0 V N 00 W N N LO N CU E M W L.L 0 O Z CU V U) 00 - 0 00 L_ 0 Q O O Z W J CV W W U cn U Q 00 0 co EXPIRES 2 2026 Project Project No. Drawn By Date 7.15.2025 51 heet S3 12%18" PLOT = 112 SCALE SHEARWALL SCHEDULE: Z 0 � v JJ LL u`i ui m 0 U r 0 N SW-6 INDICATES SHEARWALL w/ SHEATHING ONE SIDE 1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/ 8d @ 6"o.c. ALL EDGES & 6"o.c. FIELD. 2. BOLT SILL PLATE TO CONCRETE w/ 5/8 0 x 10" ANCHOR BOLTS @ 32"o.c. 3. NAIL BOTTOM PLATE TO FRAMING BELOW w/ 16d @ 4"o.c. 4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE PER DETAILS AS PROVIDED. SW-4 INDICATES SHEARWALL w/ SHEATHING ONE SIDE 1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/ 8d @ 4"o.c. ALL EDGES & 6"o.c. FIELD. 2. BOLT SILL PLATE TO CONCRETE w/ 5/8 4 x 10" ANCHOR BOLTS @ 32"o.c. 3. NAIL BOTTOM PLATE TO FRAMING BELOW w/ 16d @ 3"o.c. 4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE PER DETAILS AS PROVIDED. SW-3 INDICATES SHEARWALL w/ SHEATHING ONE SIDE 1. SHEATHING: 1/2" PLYWOOD or 7/16" O.S.B., ONE SIDE, BLOCKED, NAIL w/ 8d @ 3"o.c. ALL EDGES & 6"o.c. FIELD. 2. a. BOLT (3)2x SILL PLATE TO CONCRETE w/ 5/8 0 x 12" ANCHOR BOLTS @ 16"o.c. PER DETAIL D/S1 2. b. BOLT (2)2x SILL PLATE TO CONCRETE w/ 5/8 0 x 12" ANCHOR BOLTS @ 16"o.c. 3. NAIL BOTTOM PLATE TO FRAMING BELOW w/ 16d @ 4"o.c. 4. FASTEN DOUBLE TOP PLATE TO JOIST or BLOCKING ABOVE PER TYPICAL ROOF SHEATHING: 7/16" O.S.B., INDEX 40/20, UNBLOCKED, w/ FACE GRAIN PERPENDICULAR TO FRAMING BELOW. NAIL AS FOLLOWS: DIAPHRAGM BOUNDARY, OVER EXTERIOR WALLS, SHEAR WALLS, & DRAG STRUTS: 8d @ 6"o.c. ALL SUPPORTED EDGES: 8d @ 6"o.c. FIELD: 8d @ 6"o.c. TYPICAL FLOOR SHEATHING: 3/4" T&G O.S.B., INDEX 40/20, UNBLOCKED, LAID UP w/ FACE GRAIN DETAILS AS PROVIDED. PERPENDICULAR TO FRAMING BELOW 5. USE 3x OR (2)2x @ ALL FRAMING MEMBERS RECEIVING END NAILING STAGGER END JOINTS, GLUE & NAIL AS FOLLOWS: FROM ABUTTING PANELS. D S1 3 DIAPHRAGM BOUNDARY, OVER EXTERIOR WALLS, SHEAR WALLS, & DRAG STRUTS: 8d @ 6"o.c. ALL SUPPORTED EDGES: 8d @ 6"o.c. FIELD: 8d @ 6"o.c. NOTES: 1. USE 3"x3"x1/4" PLATE WASHERS ON ALL ANCHOR BOLTS. 2. THE PLATE WASHER SHALL EXTEND TO WITHIN 1/2" OF THE EDGE OF THE BOTTOM PLATE ON THE SIDE(S) w/SHEATHING PER NDS 2021 EDITION (SDPWS) 4.3.6.4.3 3. EXPANSION BOLTS MAY BE USED IN LIEU OF ANCHOR BOLTS w/ SAME SPACING, DIAMETER & 4 1/2"min. EMBEDMENT. 4. ALL POWDER DRIVEN NAILS SHALL BE 2 3/4" LONG(min.) x 0.156 SHANK 0. w/ MINIMUM 1 1/4" PENETRATION. 5. USE 20d NAILS @ 3x FRAMING MEMBERS. 6. a. 8d NAILS SHALL BE .131 x 2 1/2" LONG b. 10d NAILS SHALL BE .148 x 3" LONG C. 16d NAILS SHALL BE .162 x 3 1/2" LONG d. 20d NAILS SHALL BE .192 x 4" LONG mi mi 2021 CODE VERSION OO) z M CO _ CVco � COCr) 04 VJ 0 j N J W � 0�1 w 2 LL V z Y N 0)O) co W "r 0 Z a 0 W N L j �tC N N E M co�W 75 NV I..L_ U) Lu v� �Q QN� wQQ oJW OOM= 0 N ti c0 O c0 O 0 � 0 W Z J O CV W 0 = WU C/3 U 00 0 �ZM T�qh� w 24149 is �SjONAL �� EXPIRES 2 1 2026 Project FILE NUMBER DRAWN BY Date 7.15.2025 Sheet LOWER LEVEL SHEAR PLAN UPPER LEVEL SHEAR PLAN r I 00 M 0 a� 29'-0" 2'-52" 10'-0" OMIT PADS AT PATIO PER OPT. PT 44 ABOVE W/ ABU44, TYP. 24"x24"x 12" F / W/ (3)#4 B.E.W. _\ 4" CONIC. SLAB W/ FIBERMESH REINF. 0/ 2" GRAVEL BASE 0/ COMPACTED GRADE 1 SLOPE AWAY 1 /4" / FT 1 J I I I TYP w en Cm cm N o o NLn N S1 w N Al I si I STEP STEM WALL " II II II II II ' A0 DF# J01 TS 16"IIO.C.II II II II II II II II II I I 6 IL CK POLY VAP BA RIER THR( UGHC iT ' " II II II II II II II II II 6 2 � II II II II II I I s2 —1x10_ F 2�� —1 L J II TYr. II II �_lIL II II II II II III II I II II II II II A4 Cytl1p x 8" DEEP CON F00 ING A ((00Z2)) CO . TO AND OTT Si F00 I GS I II II II II II II II II II II II II II II II TYP 1-0. 2.-0 II 114'-4 II 1'4" ,11110" fi'-1 t 4'W II II 4'-4" II II 114'-411 II , 21410 1. WS210 TYP. PL - I II I� A TYP I 11- I I I ,A'_ n" L " 1l" L II Ilr� `iNl F- � _ II II II II II II II II II Li 9, � -1 1 II II � II II II III II II III II II II II III II II II II Ir 11 111 II ­_ II-1 4I1 '.72 2'- I � 1 Al I si 4� CONC. SLAB ON GRADE 10 W/ AbERMESH REINFORCEMENT Cb 0/ 2' GRAVEL BASE 0/ COMPACTED GRADE 1 SLOPE AWAY 114 / FT PT 6x6 POST ABV. W/ ABU66 BASE 36 PT 44 POST ABV. 30"00%12" W/ ABU44 BASE W/ (4)#4 B.E.W. 8'-4" 0 (1 SIM CONTROL JOINTS SIM 4" CONC. SLAB ON GRADE W/ FIBERMESH REINFORCEMENT 0/ 2" GRAVEL BASE 0/ 6 MIL POLY. V.B. 0/ COMPACTED GRADE SLOPE TOWARD DOOR ' II �JCONT. FOOTING — e REFERENCE DETAIL 24 S2 IN CASE OF MISPLACED HOLD—DOWN, TYP. HTT5 MAY BE USED IN = LIEU OF STHD14RJ 2'-0" 16'-O" 2,-8" 20'-8" lei 29'-0" FOUNDATION / MAIN LEVEL FLOOR FRAMING PLAN OF I CV —IC-4 I? I CV eV FOOTING SCHEDULE: 1- -1 1'-6"x1'-6"x8" DEEP (3)#4 EACH FOOTING WAY, TYP. F 2'-0"x2'-0"x8" DEEP ® CONC. FOOTING W/ 24 (3)#4 EACH WAY, TYP. F2'-6"x2'-6"x8" DEEP ® CONC. FOOTING W/ 30 (4)#4 EACH WAY, TYP. F- -1 3'-0"x3'-0"x8" DEEP ® CONC. FOOTING W/ L36 J (5)#4 EACH WAY, TYP. F —14'-0"x4'-O"x12" DEEP ® CONC. FOOTING W/ 48 (7)#4 EACH WAY, TYP. POINT LOAD NOTE: "PL' DESIGNATES POINT LOAD FROM ABOVE ON THE FOUNDATION PLAN. PROVIDE SOLID BLOCKING UNDER ALL LOCATIONS AND NO VENTS ARE ALLOWED BELOW PL. 3-1/2x9 GL -- --1 - II II II u I II II II II II II II II 18" DEEP 0 EN WES FLOOR TRUS S @ M" O.0 RgVID CHAS AY FOR HVAC DU I G I II II II ICI � � 1111 II II II o I II �I f f1 IL _-IIL J111 II �LIl__IL_11 1I I J J Cn I] ¢CC5U ft� C14� J CL L.� N CD o� J X J CV Q m (4)2x6 POST (2)A35 BM TO WALL (1)HGA10 (1)HGA10- 2021 CODE VERSION 2x6 ® 16" O.C. EXTERIOR WALLS TYP. U.N.O 2x4 ® 24" O.C. INTERIOR WALLS TYP. U.N.O. EXCEPT AT STAIRWELL & BEARING TO BE 2x4 ® 16" O.C. PROVIDE A MINIMUM OF 2" CLEARANCE AT ALL PLUMBING DRAINS FROM THE EDGE OF FLOOR TRUSSES, TYP. CONCEALED SPACE NOTE: PROVIDE DRAFT STOPPING @ CONCEALED FLOOR SPACES IN EXCESS OF 1000 S.F. R502.12 IRC d 0 zcm,) N Co C4 0 VJ j N J w C C� w L LL@ Z Y of N rn fn V M W m Z � � N co .. LLJ N .� Nj E M W N M 11'W L.L ~ —Qcn wO�C)Z mJQ �QC,6u-J QNZw� c�zp�C� wQ�w— pJQJ� O ZW� V =)a-UL O Q 0— CV L.L ti 00 0 00 m O w z CV Lu wU U cn Q 00 0 co EXPIRES 2 1 2026 Project FILE NUMBER DRAWN BY Date 7.15.2025 I Sheet S5 UPPER LEVEL FLOOR PLAN FRAMING PLAN (4) (2)A35 BM PT LICE PT 44 POST PT 44 POST 3 LCE4 CAP LCE4 CAP GABLE END TRUSS I I —J L— F F S1 S1 SIM - SIM w o 1 LTS20 7UYLTS20 (2)0 WALL (2)ATO WALL L(2)2x6 (2)2x6 2x10 LEDGER W/ (4)16d ® 16" O.C. & 16d ® 4" O.C. TO 2x BLOCKING BETWEEN STUDS 2x10 LEDGER W/ (4)16d ® 16" O.C. & 16d ® 4" O.C. TO 2x BLOCKING BETWEEN STUDS LOWER ROOF FRAMING PLAN D S1 TYP END TRUSS 48 DF 2 w U � N Cn w cn Of T S1 = SIM F S1 GABLE END TRUSS GABLE END TRUSS 5�ZZIxiuz ATrIG< o �AL`CESS�� o0 DRAG STRUT OVER 3.W. BELOW G TYP UPPER ROOF FRAMING PLAN x TYP TYP 2021 CODE VERSION Cn CO N _ co 0 02 N Q WCIO w u- V z 4 N � .r M W m z � 04 °0 W04 j .� N E M N M W L5 r = � m � z Q J �N Z pJ Om LL. N O � N ti 00 0 00 O Q O W z I —I J r O CV W WU 0 U Q 00 0 `5'IONAL �� EXPIRES 2 1 2026 Project FILE NUMBER DRAWN BY Date 7.15.2025 Sheet S7