Loading...
HomeMy WebLinkAbout2026.02.09 8503 Canal Rd SE YelmSCOPE OF WORK: • ADD TWO WALLS IN MASTER SUITE TO CREATE BATHROOM • ADD BATHROOM IN MASTER SUITE • REPLACE ALL BATHROOM FIXTURES • REPLACE ALL KITCHEN CABINETRY AND FIXTURES • MODIFY WATER SUPPLY LINES AS NEEDED • NEW BATHROOM 90CFM FANS, 110 CFM LAUNDRY FAN, AND DUCT WORK • NEW VENT FOR KITCHEN RANGE HOOD • ALL NEW LIGHTS, PLUGS AND SWITCHES (SEPARATE PERMITS BY OTHER CONTRACTOR) • NEW 110V INTERCOMMUNICATING SMOKE DETECTOR SYSTEM THROUGHOUT HOME • ALL NEW WINDOWS LIKE FOR LIKE • NEW DOORS AND TRIM • NEW FLOORING THROUGHOUT • DRYWALL REPAIRS AS NEEDED • INTERIOR PAINT • NEW LAYOVER ROOF • LANDSCAPING • CLEANUP Ln U N o N 60 o, N Centralia Canai �- N m Gam► Rd SE Canal Rd SE 1111, 03 n PROJECT EL LOCATION N z Yield SE View Dr NW PROJECT NORTH VICINITY MAP rF'� 1 SCALE: N.T.S. QL�/ FLOOR PLAN LEGEND: EXIST EXTERIOR WALL, 2X4 WD STUDS @ 16" OC W/ EXIST 1/2" GWB ON EXPOSED FACES. REPLACE GWB AS REQUIRED, NEW 2X4 WD STUDS @ 16" OC W/ NEW 1/2" GWB ON EXPOSED FACES EXIST 2X4 WD STUDS @ 16" OC W/ EXIST 1/2" GWB ON EXPOSED FACES. REPAIR / REPLACE GWB AS REQUIRED ® NEW 90 CFM EXHAUST FAN VENTED THRU ROOF AT BATHROOMS, NEW 110 CFM RANGE HOOD AT KITCHEN RANGE. VENTED THRU ROOF sD NEW INTERCONNECTED SMOKE DETECTOR W/ BATTERY BACKUP co NEW INTERCONNECTED SMOKE / CO2 DETECTOR W/ BATTERY BACKUP 5°X4° EGRESS 52X42 EGRESS BEDROOM BEDROOM SD SD 10'-10"xl 0'4' 8'-10"x9'4' P8 PR 2Wa _� xI �N CL CL N CL 0 HALL PR 2WX A X I N F(o BEDROOM sD BAT SD 10' 10"x12' 2" 5' 0"x12' 2" yo, I I L_ _ KITCHEN 9'-5"xl2'-2" 48'-0" FLOOR PLAN NOTES: 1. BEDROOM WINDOWS SHALL MEET EGRESS, SEE LOCATION & ON PLAN. 2. ALL EXTERIOR DOORS & WINDOWS SHALL BE R-22 = U-0.045 MIN. HDR HT = 6-8", UNO. EGRESS WINDOWS SHALL PROVIDE CLEAR OPENING OF 5.0 SF, 20"W MIN, 24"H MIN, & W/ A 42" MAX SILL HT. 3. ALL REPLACEMENT INSULATION SHALL BE A MIN: a. WALLS = R-15 BATT INSULATION b. FLOORS = R-30 BATT INSULATION C. CEILING = R-49 BLOW-IN INSULATION 4. ALL SHOWERHEADS & KITCHEN SINK FAUCETS SHALL BE 1.75 GPM MAX & ALL LAV FAUCETS SHALL BE 1.0 GPM MAX. 5. ALL NEW APPLIANCES & HVAC EQUIPMENT SHALL BE HIGH - EFFICIENCY ENERGY STAR RATED. 6. WHOLE -HOUSE FRESH -AIR VENTILATION SYSTEM: (0.01 X 1,344 SF) + [7.5 X (4 BED +1) = 43.44 CFM MIN, COORDINATE W/ MECH DESIGNER FOR FRESH -AIR INTAKE. 7. ALL FINISHES, FIXTURES, & CABINETS, APPLIANCES, SHALL BE NEW. 42X52 DH 42X59 DH LIVING 14'-11 "xl4'-11" DINING 9'-4"xl2'-2" WHOLE-F FRESH -A VENTILA- SYSTEM EGRESS 2�X* SL . 3IX32 DH 5`-'X69 SLGDR 1ST FLOOR PLAN SCALE: 3/16" = l'-0" EGRESS BEDROOM SD 10'-10"xl4'-3" 1,344 SF LIVING AREA PROJECT NORTH JZ NZ Oa i •Q a ii CO o a3 V1 ~ ai z >o G" J w 06 0 1_ O Z 2 ww C G ti rn W J 00 ao UQ Q J Q E LU U w U) O U) U U 0 (a z i Z U _ �z O E 00 �Lo co 00 PROJECT NO: 26002.00 DATE: 02.09.2026 SHEET: FLOOR PLAN A1.1