HomeMy WebLinkAbout2025.11.18 TACO BELL YELM-HVAC PERMIT SET“
HVAC LEGENDS
AND NOTES
M0.0
REVISIONS
JOB NUMBER
CADD FILE
DATE
CHECKED
DRAWN
DESIGNED
TITLE
DESCRIPTIONDATEBYNO
TA
C
O
B
E
L
L
-
Y
E
L
M
13
1
0
Y
E
L
M
A
V
E
E
,
YE
L
M
,
W
A
,
9
8
5
9
7
2025.43
MB
KB
MB
-11/18/25 MEB PERMIT SET
2025.43 M0.0.DWG
11/18/2025
8021 State Avenue
Marysville, WA 98270
p (425)744-6033
www.beronaengineers.com
ROOFTOP UNIT (RTU) SCHEDULE
EQUIPMENT TAG MANUFACTURER MODEL
NOM.
CAP
(TONS)
AREA SERVED
DESIGN
AIRFLOW
(CFM)
OSA
AIRFLOW
(CFM)
ESP MOTOR
HP
TOTAL COOL
CAPACITY
SENS COOL
CAPACITY
HEAT PUMP
HEATING CAPACITY
ALT HEAT
FUEL
HEATING
CAPACITY
INPUT
HEATING
OUTPUT VOLT / Hz /PH EER IEER AFUE %MCA
(AMP)MOCP DIMENSIONS
(L x W x H)
NET
WEIGHT
(LBS)
NOTES
RTU-1 (EXIST)TRANE YCD151C3H0BB (R-22)12.5 DINING 4,400 100 (ADJ)0.75 5 154,000 NA -NAT GAS 250,000 203,000 208-230/60/3 11.3 NA 81 70 90 88" X 53" X 41"1,502 (E) REMOVED, CONTROLS, POWER AND GAS DISCONNECTED
RTU-2 (EXIST)TRANE YCD181C3LBCA (R-22)15 KITCHEN 5,300 100 (ADJ)0.75 5 189,000 NA -NAT GAS 350,000 284,000 208-230/60/3 11.5 NA 81 80 100 99" X 53" X 52"1,729 (E) REMOVED, CONTROLS, POWER AND GAS DISCONNECTED
RTU-1 (NEW)TRANE YHC060F3RHA (410A)5 DINING 2,000 200(ADJ)1 1 61,000 45,830 -NAT GAS 130,000 106,600 208-230/60/3 12.8 15 80 26 40 70" X 44" X 41"755 1-18
RTU-2 (NEW)TRANE YSJ150A3SOH 12.5 KITCHEN 5,000 200(ADJ)1.5 4.6 146,470 111,000.0 NAT GAS 250,000 194,400 208-230/60/3 10.8 14 78 64 90 123" X 87" X 66"1,404 1-18
NOTES:
1. POWER WIRING, CONDUIT AND DISCONNECT BY ELECTRICAL CONTRACTOR.
2. NEW RTU WITH PREFAB ROOF CURB, CONTRACTOR TO VERIFY AND COORDINATE WITH GENERAL cONTRACTOR. IiF EXISTING CURB TO BE REUSED THEN, PROVIDE RTU WITH CURB ADAPTER. PROVIDE STRUCTURAL CALCULATIONS IF REQUIRED.
3. WITH 100% DRY BULB ECONOMIZER. (MOTORIZED) PROVIDE CONTROLS TO CLOSE OSA AND OPEN RA DAMPERS WHEN UNIT IS OFF. PER 2021 WSEC
4. WITH R410A REFRIGERANT.
5. WITH STANDARD CONDENSER COIL WITH HAIL GUARD.
6. WITH MOTORIZED RELIEF DAMPER. PER 2021 WSEC
7. WITH MICROPROCESSOR CONTROLS. PIVOT SMART THERMOSTAT - ELECTROMECHANICAL
8. WITH FROST STAT.
9. WITH MEDIUM GAS HEAT (STAINLESS STEEL HEAT EXCHANGER).
10. WITH 7 DAY PROGRAMMABLE THERMOSTAT. PER 2021 WSEC
11. WITH DUAL COMPRESSORS.
12. WITH OPTIONAL BELT DRIVE MOTOR.
13. WITH RETURN DUCT SMOKE DETECTOR. INTERTIE WITH FIRE ALARM SYSTEM.
14. VERIFY THROUGH THE BASE SINGLE POINT ELECTRICAL SUPPLY CONNECTION.
15. MERV 13, 2" FILTERS
16. PROVIDE WITH CONCIENCE OUTLET, 120/1PH
17. PROVIDE NAT GAS PRV AS REQUIRED. 18. Unit weight does not include accessories, like economizer, curb adapter, existing adapter.
HVAC
SCHEDULES
M0.1
REVISIONS
JOB NUMBER
CADD FILE
DATE
CHECKED
DRAWN
DESIGNED
TITLE
DESCRIPTIONDATEBYNO
TA
C
O
B
E
L
L
-
Y
E
L
M
13
1
0
Y
E
L
M
A
V
E
E
,
YE
L
M
,
W
A
,
9
8
5
9
7
2025.43
MB
KB
MB
-11/18/25 MEB PERMIT SET
2025.43 M0.1.DWG
11/18/2025
8021 State Avenue
Marysville, WA 98270
p (425)744-6033
www.beronaengineers.com
DEMO ROOF
PLAN
M1.2
REVISIONS
JOB NUMBER
CADD FILE
DATE
CHECKED
DRAWN
DESIGNED
TITLE
DESCRIPTIONDATEBYNO
TA
C
O
B
E
L
L
-
Y
E
L
M
13
1
0
Y
E
L
M
A
V
E
E
,
YE
L
M
,
W
A
,
9
8
5
9
7
2025.43
MB
KB
MB
-11/18/25 MEB PERMIT SET
2025.43 M1.2.DWG
11/18/2025
8021 State Avenue
Marysville, WA 98270
p (425)744-6033
www.beronaengineers.com
S-550
HVAC RCP
PLAN
M2.1
REVISIONS
JOB NUMBER
CADD FILE
DATE
CHECKED
DRAWN
DESIGNED
TITLE
DESCRIPTIONDATEBYNO
TA
C
O
B
E
L
L
-
Y
E
L
M
13
1
0
Y
E
L
M
A
V
E
E
,
YE
L
M
,
W
A
,
9
8
5
9
7
2025.43
MB
KB
MB
-11/18/25 MEB PERMIT SET
2025.43 M2.1.DWG
11/18/2025
8021 State Avenue
Marysville, WA 98270
p (425)744-6033
www.beronaengineers.com
HVAC ROOF
PLAN
M2.2
REVISIONS
JOB NUMBER
CADD FILE
DATE
CHECKED
DRAWN
DESIGNED
TITLE
DESCRIPTIONDATEBYNO
TA
C
O
B
E
L
L
-
Y
E
L
M
13
1
0
Y
E
L
M
A
V
E
E
,
YE
L
M
,
W
A
,
9
8
5
9
7
2025.43
MB
KB
MB
-11/18/25 MEB PERMIT SET
2025.43 M2.2.DWG
11/18/2025
8021 State Avenue
Marysville, WA 98270
p (425)744-6033
www.beronaengineers.com
1310
HVAC
ELEVATION
PLAN
M3.0
REVISIONS
JOB NUMBER
CADD FILE
DATE
CHECKED
DRAWN
DESIGNED
TITLE
DESCRIPTIONDATEBYNO
TA
C
O
B
E
L
L
-
Y
E
L
M
13
1
0
Y
E
L
M
A
V
E
E
,
YE
L
M
,
W
A
,
9
8
5
9
7
2025.43
MB
KB
MB
-11/18/25 MEB PERMIT SET
2025.43 M3.0.DWG
11/18/2025
8021 State Avenue
Marysville, WA 98270
p (425)744-6033
www.beronaengineers.com
Existing Curb
1
2
3
New RTU
CURB ADAPTER INSTALLATION
1.Before removing the existing unit, verify the dimensions of the existing curb O.D. & the new unit with the
enclosed drawings. (Note that the curb adapter is oversized by 1-1/2" in both directions.
2.Have a licensed professional turn off and disconnect all utilities from the old unit.
3.Remove the old unit and verify the return & supply sizes and locations with the enclosed drawings.
4.Remove all the old gasket material from the existing curb (1) and replace with the new gasket material
that is supplied with the curb.
5.Set curb adapter (2) on the existing curb (1) in the proper orientation.
6.Remove lifting lugs from curb if need be.
7.Apply gasket material to the top rails and perimeter of the new curb adapter.
8.Install equipment rail; if applicable, shimming may be required (shims supplied by others).
9.Set new unit (3) on curb adapter (2).
10.Have a licensed professional reconnect necessary utilities to the new rooftop unit and verify
utilities are connected before turning back on.
11.CDI recommends that the adapter be attached to the existing curb once the RTU is in place and running
properly. Attachment of the adapter should be done by using #12 self drilling screws (of sufficient length
to screw into existing curb) at approximate spacing of 10"-12"O.C. and in approx 6" from the end of the
curb. The screws shall be placed through the 3" weather skirt(overhang), making sure not to damage the
roofing material of existing curb.
DIMENSIONED AND TOLERENCED PER ANSI Y14.5M-1982
RED LINES INDICATE
GASKET LOCATION
HVAC DETAILS
M4.0
REVISIONS
JOB NUMBER
CADD FILE
DATE
CHECKED
DRAWN
DESIGNED
TITLE
DESCRIPTIONDATEBYNO
TA
C
O
B
E
L
L
-
Y
E
L
M
13
1
0
Y
E
L
M
A
V
E
E
,
YE
L
M
,
W
A
,
9
8
5
9
7
2025.43
MB
KB
MB
-11/18/25 MEB PERMIT SET
2025.43 M4.0.DWG
11/18/2025
8021 State Avenue
Marysville, WA 98270
p (425)744-6033
www.beronaengineers.com