Loading...
HomeMy WebLinkAbout2025.11.18 TACO BELL YELM-PLUM PERMIT SETPLUMBING LEGENDS AND NOTES P0.0 REVISIONS JOB NUMBER CADD FILE DATE CHECKED DRAWN DESIGNED TITLE DESCRIPTIONDATEBYNO TA C O B E L L - Y E L M 13 1 0 Y E L M A V E E , YE L M , W A , 9 8 5 9 7 2025.43 MB KB MB -11/18/25 MEB PERMIT SET 2025.43 P0.0.DWG 11/18/2025 8021 State Avenue Marysville, WA 98270 p (425)744-6033 www.beronaengineers.com PLUMBING FIXTURE UNIT COUNT Fixture WSFU DFU QTY FU TOTAL GPM SIZE QTY FU TOTAL SIZE WC Tank 2 2.5 5 2 3 6 LAV 2 1 2 2 1 2 HS 2 2 4 2 2 4 3 COMP 1 2 2 1 3 3 ICE MACH.1 0.5 0.5 1 0 0 DW 1 3 3 1 3 3 FS 3 0 0 3 3 9 Mop 1 3 3 1 3 3 HB 0 2.5 0 0 0 0 FD 2 0 0 2 2 4 TOTAL 19.5 15 1"34 4" PIPE MATERIAL, JOINTS, HANGERS AND SUPPORTS MATERIALS SYSTEM TYPES OF JOINTS HORIZONTAL HANGERS VERTICAL SUPPORTS ABS DWV DVW SOLVENT CEMENTED ALL SIZES, 4 FEET; ALLOW FOR EXPANSION EVERY 30 FEET³ BASE AND EACH FLOOR; PROVIDE MID-STORY GUIDES PROVIDE FOR EXPANSION EVERY 30 FEET COPPER DOM COLD/HOT WATER (BELOW GRADE, THRU BLDG, WATER RISERS) SOLDERED, BRAZED, THREADED, MECHANICAL 1-1/2 INCHES AND SMALLER, 6 FEET; 2 INCHES AND LARGER, 10 FEET EACH FLOOR, NOT TO EXCEED 10 FEET5 CPVC DOM COLD/HOT WATER (BELOW GRADE, THRU BLDG, WATER RISERS) ORANGE PRIMER, SOLVENT CEMENTED 1 INCH AND SMALLER, 3 FEET; 1-1/4 INCHES AND LARGER, 4 FEET BASE AND EACH FLOOR; PROVIDE MID-STORY GUIDES PEX DOM COLD/HOT WATER, RECIRC BRANCHES COLD EXPANSION, INSERT AND COMPRESSION 1 INCH AND SMALLER, 32 INCHES; 1-1/4 INCHES AND LARGER, 4 FEET BASE AND EACH FLOOR; PROVIDE MID-STORY GUIDES NOTES: 1 SUPPORT ADJACENT TO JOINT, NOT TO EXCEED 18 INCHES. 2 BRACE NOT TO EXCEED 40 FOOT INTERVALS TO PREVENT HORIZONTAL MOVEMENT. 3 SUPPORT AT EACH HORIZONTAL BRANCH CONNECTION. 4 HANGERS SHALL NOT BE PLACED ON THE COUPLING. 5 VERTICAL WATER LINES SHALL BE PERMITTED TO BE SUPPORTED IN ACCORDANCE WITH RECOGNIZED ENGINEERING PRINCIPLES WITH REGARD TO EXPANSION AND CONTRACTION, WHERE FIRST APPROVED BY THE AUTHORITY HAVING JURISDICTION. PLUMBING PIPE INSULATION SCHEDULE - WA STATE ENERGY CODE: 2018 INTERNATIONAL ENERGY CODE WITH WASHINGTON AMENDMENTS TABLE C403.2 SPECIFICATION: 220716 PLUMBING PIPING INSULATION PIPING SYSTEM TEMP RANGE (DEG F) THERMAL COND. MEAN RATING TEMPERATURE INSULATION MATERIAL NOTES <1" 1" TO <1-1/2"1-1/2" TO 4"4" - 8"OVER 8" DOMESTIC COLD WATER 40-60 0.21-0.27 75 MPI 0.5 0.5 1.0 1.0 1.0 1, 2, 4 NON-POTABLE COLD WATER 40-60 0.21-0.27 75 MPI 0.5 0.5 1.0 1.0 1.0 1, 2, 4 DOMESTIC HOT WATER 105-140 0.21-0.28 100 MPI 1.0 1.0 1.5 1.5 1.5 1, 2, 4, 5 NON-POTABLE HOT WATER 105-140 0.21-0.28 100 MPI 1.0 1.0 1.5 1.5 1.5 1, 2, 4, 5 RAINWATER DRAINAGE ALL 0.21-0.28 75 MPI 1.0 1.0 1.0 1.0 1.0 6 FOR FURTHER INFORMATION ON INSULATING SYSTEMS AND EQUIPMENT EITHER LISTED OR NOT LISTED, SEE SPECIFICATION SECTION 220700 "PLUMBING INSULATION." MPI: MINERAL WOOL PREFORMED PIPE INSULATION E: ELASTOMERIC CLOSED CELL INSULATION PF: POLYURETHANE FOAM CGPI: CELLULAR GLASS PIPE INSULATION CAL-SIL: CALCIUM SILICATE NOTES: 1. FOR PIPING CLAMPED TO UNISTRUCT SUPPORTS, UTILIZE RIGID INSERTS WITH SHEETMETAL SHIELDS CONTINUOUS THROUGH THE HANGER; UTILIZE CALCIUM SILICATE INSERTS OR STYRENE INSERTS. 2. FOR PIPING SUPPORTED FROM CLEVIS HANGERS, IF RIGID INSERTS ARE NOT UTILIZED THE INSULATION SHALL FULLY ENCLOSE THE HANGER AND BE SEALED AT THE TOP AROUND THE SUPPORT ROD; IF RIGID INSERTS ARE UTILIZED THE INSULATION SHALL BE CONTINUOUS THROUGH THE HANGER; INSERT MATERIAL TO BE CALCIUM SILICATE INSERTS OR STYRENE INSERTS. 3. DOMESTIC WATER PIPING AND WASTE DRAIN TRAPS EXPOSED TO OUTDOOR CONDITIONS SUCH AS THE GARAGE ENTRY AND FIRST GARAGE LEVEL BELOW GRADE SHALL BE HEAT TRACED AND INSULATED. 4. JACKETING: ALUMINUM ROLLED JACKETING (ARJ) APPLIED TO EXTERIOR PIPING INSULATION EXPOSED TO WEATHER (I.E. ROOFTOP PIPING). PVC JACKETING WILL BE UTILIZED ON ALL EXPOSED INSULATION WITHIN 6 FEET OF THE FLOOR (PUBLIC AREAS). 5. FOR PIPES SMALLER THAN 1-1/2 INCH AND LOCATED IN PARTIONS WITHIN A CONDITIONED SPACE, MAY REDUCE THICKNESSES BY 1 INCH BUT TOTAL THICKNESS TO NOT BELOW 1" AS ALLOWED BY ENERGY CODE. 6. PROVIDE INSULATION ON ALL HORIZONTAL PRIMARY AND OVERFLOW ROOF DRAINAGE BELOW THE ROOF DECK. WHERE THE HORIZZONTAL RUN IS LESS THAN 15', PROVIDE INSULATION ON THE RISER DOWN THROUGH THE NEXT FLOOR BELOW THE ROOF DECK, OR A MINIMUM OF 15'. 7. DIRECT BURIED PIPING THAT CONVEYS FLUID AT OR BELOW 60 DEG F IS EXEMPT FROM INSULATION PER WSEC. 8. DIRECT BURIED HEATING AND HOT WATER SYSTEM PIPING MAY REDUCE THICKNESS BY 1.5" BUT NOT TO A THICKNESS LESS THAN 1". 9. DOMESTIC HOT WATER WITH ONE WAY DISTRIBUTION TO FIXTURE THAT IS INSTALLED IN-SLAB PEX WITH A SMURF TUBE AND AIR BARRIER MEETS WASHINGTON STATE ENERGY CODE PER C404.6. 10. FOR PIPING SMALLER THAN 1-1/2 INCH AND LOCATED IN PARTITIONS WITHIN A CONDITIONED SPACE, MAY REDUCE THICKNESS BY 1 INCH BUT TOTAL THICKNESS TO NOT BELOW 1" AS ALLOWED BY ENERGY CODE. PLUMBING FIXTURE SCHEDULE MARK FIXTURE DESCRIPTION MANUFACTURER/MODEL NUMBER LOCAL CONNECTION NOTES W V CW HW FS FLOOR SINK PVC 12" SQUARE FLOOR SINK, 8" DEEP, WITH ALUMINUM OR PVC DOME STRAINER AND LOOSE SET PVC SLOTTED TOP GRATE. SET FLOOR SINK LIP FLUSH WITH FLOOR TILE EXISTING 4 2 --EXISTING TO REMAIN FD FLOOR DRAIN PVC FLOOR DRAIN, 5" DIA, IF PVC OR ABS DRAINS ARE USED, SCHEDULE 80 PVC DRAIN PIPE SHALL BE USED FOR THE FIRST 10'-0" FROM THE DRAIN. EXISTING 3 2 --EXISTING TO REMAIN HD-1 HUB DRAIN CAST IRON DEEP SEAL P-TRAP WITH FUNNEL, NO-HUB OUTLET AND BRASS GASKETED CLEANOUT PLUG. JOSAM/ MODEL: 88213 WADE/ MODEL: 2453EF ZURN/ MODEL: Z-1019 3 2 --INDIRECT DRAIN P-1 WATER CLOSET WHITE VITREOUS CHINA FLOOR MOUNTED FLUSH VALVE. SLOAN 111-1.6 AT 1.6 GPF WITH TOP SPUD. ELONGATED SEAT WITH NO COVER, OLSONITE. FLUSH VALVES SHALL BE RIGHT OR LEFT HAND AS REQUIRES TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL, VERIFY. AM. STD: MADERA 3451.576 KOHLER BARRINGTON K-4305 4 2 1/2 -NEW P-2 LAVATORY WHITE VITREOUS CHINA, WALL HUNG, WITH CONCEALED ARMS SUPPORT, 4" CENTERS, WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE, FLAT GRID STRAINER, BRAIDED WATER LINES FAUCET: FURNISHED BY OWNER-INSTALLED BY G.C. ELECTRONIC SENSOR TYPE FAUCET. SLOAN SF-2300, ADA COMPLAINT. SEE 5/P6.0 FOR LAV SUPPORT DETAIL, 0.5 GPM AERATOR AM.STD. COMRADE/ MODEL: 0124.131 KOHLER "SOHO" MODEL: K-2084 4 2 1/2 -NEW P-3 HAND SINK S-1: STAINLESS STEEL HAND SINK, WALL HUNG, INCLUDES A 6" GOOSENECK STAINLESS FAUCET W/ SINGLE KNEE PEDAL. BRAIDED WATER LINES, 0.5 GPM AERATOR. EXISTING 1 1/2 1 1/2 1/2 1/2 SINK TO BE RELOCATED. P-4 PREP SINK ROUGH-IN AND CONNECT. SEE ARCHITECTURAL NEW 2 1 1/2 1/2 1/2 INDIRECT DRAIN P-5 THREE COMPARTMENT EXISTING TO REMNAIN AND REPIPED EXISTING 2 1 1/2 1/2 1/2 INDIRECT DRAIN MSK-1 MOP SINK MOP SINK: AERO-3MP-2121-6 W/ 48" HIGH S.S. LEFT SIDE AND BACK-SPLASH. FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. FAUCET: T&S #B2465, WITH VACUUM BREAKER, FURNISHED BY OWNER, INSTALLED BY CONTRACTOR. EXISTING 3 2 1/2 1/2 EXISTING TO REMAIN DWH-1 WATER HEATER GAS FIRED WATER HEATER, 96% THERMAL EFF, 199,900 BTUH INPUT, 67 DEG. F RISE @ 5.6 GPM. 2" CPVC FLUE & INTAKE, ASME RATED TEMPERATURE AND PRESSURE RELIEF VALVE, RECIRCULATION SYSTEM INCLUDING PUMP, ELECTRONIC IGNITION SYSTEM, AND ELECTRONIC CONTROLS NAVIEN NPE-S2 -- 3/4 3/4 INDIRECT DRAIN CP-1 HW RECIRC PUMP EXTERNAL INLINE PUMP. 2 GPM MINIMUM, 3 GPM MAXIMUM BASED ON 11 PSI PRESSURE DROP AT 3 GPM PER HWH-1. PROVIDE WITH PIPING, BALL SHUFOFF VALVES, CHECK VALVE AND FITTINGS. PROVIDE CIRCUIT SETTER TO SET MAX FLOW THROUGH HWH-1. GRUNDFOS UP15-10SU7P/TLC 3/4"NEW EX-1 EXPANSION TANK EXPANSION TANK, STEEL, EXPANSION MEMBRANE 150 PSI, 160 DEG. F, 12 GALLON CAPACITY WATTS SERIES DETA AMTROL SERIES ST WILKINS SERIES WXTP -- 3/4 3/4 NEW BP-1 BACKFLOW PREVENTOR REDUCED PRESSURE ZONE BACKFLOW PREVENTER, CAST BRONZE CONSTRUCTION WITH QUARTER TURN FULL-PORT BALL VALVES AND BRONZE STRAINER. WATTS/ MODEL: LF009M2QTS WILKINS/ MODEL: 975XLS FEBCO/ MODEL: 860 ----NEW PLUMBING SCHEDULES P0.1 REVISIONS JOB NUMBER CADD FILE DATE CHECKED DRAWN DESIGNED TITLE DESCRIPTIONDATEBYNO TA C O B E L L - Y E L M 13 1 0 Y E L M A V E E , YE L M , W A , 9 8 5 9 7 2025.43 MB KB MB -11/18/25 MEB PERMIT SET 2025.43 P0.1.DWG 11/18/2025 8021 State Avenue Marysville, WA 98270 p (425)744-6033 www.beronaengineers.com DEMO FLOOR PLAN P1.0 REVISIONS JOB NUMBER CADD FILE DATE CHECKED DRAWN DESIGNED TITLE DESCRIPTIONDATEBYNO TA C O B E L L - Y E L M 13 1 0 Y E L M A V E E , YE L M , W A , 9 8 5 9 7 2025.43 MB KB MB -11/18/25 MEB PERMIT SET 2025.43 P1.0.DWG 11/18/2025 8021 State Avenue Marysville, WA 98270 p (425)744-6033 www.beronaengineers.com S-550 B-290 N-061 B-241B-251 PLUMBING FLOOR PLAN P2.1 REVISIONS JOB NUMBER CADD FILE DATE CHECKED DRAWN DESIGNED TITLE DESCRIPTIONDATEBYNO TA C O B E L L - Y E L M 13 1 0 Y E L M A V E E , YE L M , W A , 9 8 5 9 7 2025.43 MB KB MB -11/18/25 MEB PERMIT SET 2025.43 P2.1.DWG 11/18/2025 8021 State Avenue Marysville, WA 98270 p (425)744-6033 www.beronaengineers.com PLUMBING ROOF PLAN P2.2 REVISIONS JOB NUMBER CADD FILE DATE CHECKED DRAWN DESIGNED TITLE DESCRIPTIONDATEBYNO TA C O B E L L - Y E L M 13 1 0 Y E L M A V E E , YE L M , W A , 9 8 5 9 7 2025.43 MB KB MB -11/18/25 MEB PERMIT SET 2025.43 P2.2.DWG 11/18/2025 8021 State Avenue Marysville, WA 98270 p (425)744-6033 www.beronaengineers.com HW, HWC, CW WASTE AND VENT RISER DIAGRAM-STREAM P3.0 REVISIONS JOB NUMBER CADD FILE DATE CHECKED DRAWN DESIGNED TITLE DESCRIPTIONDATEBYNO TA C O B E L L - Y E L M 13 1 0 Y E L M A V E E , YE L M , W A , 9 8 5 9 7 2025.43 MB KB MB -11/18/25 MEB PERMIT SET 2025.43 P3.0.DWG 11/18/2025 8021 State Avenue Marysville, WA 98270 p (425)744-6033 www.beronaengineers.com PLUMBING DETAIL P4.0 REVISIONS JOB NUMBER CADD FILE DATE CHECKED DRAWN DESIGNED TITLE DESCRIPTIONDATEBYNO TA C O B E L L - Y E L M 13 1 0 Y E L M A V E E , YE L M , W A , 9 8 5 9 7 2025.43 MB KB MB -11/18/25 MEB PERMIT SET 2025.43 P4.0.DWG 11/18/2025 8021 State Avenue Marysville, WA 98270 p (425)744-6033 www.beronaengineers.com