HomeMy WebLinkAbout101189063R1_SIGNEDWA-5
0
7
P# 21724440500
15425
P# 22719330801
504
P# 21724440500
15425
MI
L
L
R
D
S
E
100T
Y271
X96896FS
X96896BP
WA-5
0
7
YEL
26
YEL
26
LO
A
D
S
I
D
E
LOA
D
S
I
D
E
ROW=90'
EOR=28'
ROW=40'
EOR=34'
CL
CL
CL
CL
CL
100T
X96896FS
X96896BP
NVicinity Map
10
1
1
8
9
0
6
3
R
1
FOREMAN (CHECK BOX WHEN COMPLETED)
PSE Equipment LOCKED/SECURED & Work Area left in CLEAN/SAFE Condition.
Grid, Cable, and Switch numbers INSTALLED & VERIFIED.
Field Changes RED-LINED on As-built.
Indicate correct FUSE SIZE on As-built & VERIFY proper PHASE.
Foreman's Signature _______________________________________________
Print Name ___________________________________ Date ______________
Material VERIFIED and CHANGES noted on Paperwork.
Total PRIMARY Cable noted on As-built.
Company ID#'s RECORDED in correct location on As-built.
Deviations noted on the As-built and their reason.
I certify that the work performed meets PSE's standards and procedures
and that all quality requirements are met.
YEL-26 SW#Y271 INST 3 FS MILL R
PHONE
CABLE TV
11953620 101189063
PROJECT PHASE
PWR
NOTIF#ORDER#
Superior
OH Expense
THIS SKETCH NOT TO BE RELIED UPON FOR EXACT LOCATION OF EXISTING FACILITIES
CALL (800) 424-5555
2 BUSINESS DAYS BEFORE YOU DIG
For contacts below dial 1-888-CALL PSE (225-5773)
JOB SITEOVERHEAD CONSTRUCTION
Poles & Structures
-Poles are to be installed or relocated as staked. Unless otherwise noted, all pole location
measurements are from the face of the pole.
-All new poles set shall be the class indicated on the sketch, or better. Do not set a lower class
pole than specified.
-Install ground plate assembly on all new poles. Install Switch Ground Assembly per standard
specification 6014.1000 at new gang operated switch locations.
-Install grid numbers on all new and existing poles as shown on sketch.
-Straighten existing poles as indicated or as necessary.
-Treat all field-drilled poles with copper napthenate wood preservative.
-Remove old poles after communication companies have transferred off and return to PSE
storeroom. Fill and crown pole holes and restore area similar to adjacent landscaping.
Conductors & Equipment
- Transfer all overhead and underground primary, secondary and service conductors and guys to
new poles set, unless otherwise indicated on this sketch.
- Transfer existing transformers to new poles unless otherwise indicated on this sketch.
- Use stirrups to connect all overhead and underground primary taps, and all transformers. Install
at all sites being worked within the scope of the project where they are currently missing.
- Use 397 AAC and Ampact connectors for all bare conductor feeder jumpers and 600 amp switch
jumpers. Install tree wire conductor for jumpers on all poles that are double deadended with tree
wire.
- Apply grit inhibitor on all Ampact, stirrup, and dead-end connections.
- Connect primary taps and transformers to same phase as existing unless otherwise shown on
the drawing.
- All neutral connections to be made with solid compression connectors. Connect all pole grounds
to common neutral.
- Use Load-interrupter cutouts (with arc shields) on all primary overhead and underground taps
with fused protection above 40T.
- Install Wildlife Protectors on all transformers.
PLAN VIEW
SCALE: 1" = 50'
GENERAL SPECIFICATIONS
Electric Project Scope Document
Project Information:
Project Name: YEL-26 SW#Y271 INST 3 FS MILL R
Notification Number: 11953620
System Planner: Tim LoPresto 425-748-6374
Required In-Service Date: 12/31/2027
Project Summary:
At SW# Y271, Grid # 559260-147279 install 3 Siemens Fusesavers. Install stirrups
with hot taps and all jumpers will be insulated.
Non-storm customer minute interruptions saved: 1246
Non-storm customer interruptions saved: 21
Non-storm outages saved: 0.12
Project Justification:
In PSE's service territory, it is projected that 60% of the outages on overhead systems
are temporary in nature, such as a limb falls through the primary line making contact
along the way. Fusesavers are devices that when placed in series with fused cutouts
will provide an instantaneous operation and then after a period of time reclose. If the
fault is temporary then customers will see the brief drop and pick, but if permanent it
will allow the fuse to blow.
Construction Criteria:
Use temporary jumpers around existing fuses to keep system in service and avoid the
need for customer outages during the installation of the Siemens Fuse Savers.
Install grid number boards on PSE poles where they're missing.
Install new OH switch number boards if not present.
Provide Planner with preliminary and final work sketches and notify Planner when the
project is scheduled, then complete. Keep Planner notified of correspondence with
ROW.
Safety
-Refer to PSE standards 6275.3000 and 6275.6000 for system ground requirements.
-Refer to PSE standards 6275.9050 for personal protective grounding requirements.
-Refer to PSE standards 6275.9150 for vehicle grounding and barricading
requirements.
-Proper line clearances shall be taken at the beginning, and released at the end, of
each work day, or as otherwise instructed by the System Operator.
-Provide signs, barricades, and traffic control in conformance with permit regulations.
-Utilize flagging and other vehicle traffic control as necessary and in conformance with
local traffic regulations.
-Maintain traffic flow as required by permitting agency.
Erosion & Sediment Control
-Refer to PSE standards 0150.3200 for minimum requirements.
-Comply with all requirements of permitting agency.
-Installed erosion & sediment devices shall be maintained until vegetation has been
re-established or disturbed soil has been otherwise permanently stabilized.
UTILITIES
CONTACT
PHONE#
COUNTY
1/4 SEC
U-MAP NO (POWER)
OP MAP
Emer Sect Gas Wk Ctr POWER WK CTR
PLAT MAP
JOINT FACILITIES ARRANGEMENTS
DRAWN BY
CHECKED BY
APPROVED BY
FOREMAN #1
FOREMAN #2
MAPPING
INCIDENT MAOP
Gas Order Elect Order
SCALE PAGE
ENGR - POWER
ENGR - GAS
FUNCTION
PROJECT MGR
PERMITREAL ESTATE/EASEMENT
2
1
REV#
3
DATE DESCRIPTIONBY
CONTACT PHONE NO DATE
OH CKT MAP CIRCUIT NOUG CKT MAP
K. BARTENHAGEN 253-561-4641 11/13/25
N. COSME 253-569-6158 11/13/25
N/A N/A N/A
C. RAVANERA 253-308-8956 11/13/25
N/A CITY OF YELM
YEL-26 SW#Y271 INST 3 FS MILL R
INSTALL 3-PH FUSESAVERS W/ BYPASS
15425 WA-507, YELM, WA 98597
N/A N/A
N/A 101189063R1
AS NOTED 1/1
THURSTON N/A N/A QSTHLE
SE 24-01-17 N/A N/A
1701E096 1702E116 1701E096 YEL-26
WAVE BROADBAND COMCAST - OLYMPIA
2/25/26 ALEX V.CITY OF YELM JURISDICTION
N/A N/A N/A
N/A N/A N/A
Potelco, Inc.DESIGNED BY
Installed at site:
Grid Number:
Material ID#:
Foreman to redline the following information
INSTALLATION
Company ID#:
Primary phase connected to:
FUSE SAVER TRIP SAVER
P01
559260-147279
9946707
*
No
No
No
Yes
Yes
Yes
"Flagging Required"
"Outages Required"
"Locates Required"
No
No
Yes
Yes
"Joint Trench Coordination Required"
"Vegtation Management Required"
UNITS OF PROPERTY
REMOVAL ONLY
MATERIAL QTY
DIST. ARRESTERS
DIST. CUTOUTS
DIST. INSULATORS
TRANS. ARRESTERS
TRANS. INSULATORS
CROSSARMS - DISTRIBUTION
CROSSARMS - TRANSMISSION
Installed at site:
Grid Number:
Material ID#:
Foreman to redline the following information
INSTALLATION
Company ID#:
Primary phase connected to:
FUSE SAVER TRIP SAVER
P01
559260-147279
9946707
Installed at site:
Grid Number:
Material ID#:
Foreman to redline the following information
INSTALLATION
Company ID#:
Primary phase connected to:
FUSE SAVER TRIP SAVER
P01
559260-147279
9946707
Removal
593266069
108168568
SITE SPECIFIC NOTES:
P01: 559260-147279
-EX 80' CL H2, 2010 POLE TO REMAIN
-INST 3Ø ARM MTD FUSESAVERS ON BUCK ARM (6022.1061, FUS3AMB) 2-24Nx2
-INST BYPASS C/O'S ON BUCK ARM (6022.1061)
-HANG FUSE DOORS AT NEUT LEVEL
-REPL EXIST L/I C/O'S ON BUCK ARM (6022.1061) 2-24O
-FUSE AT 100T
-RETIRE SW# Y271
-INST SW# X96896FS
-INST SW# X96896BP
JOB SITE
SCALE: 1:880
OH CIRCUIT (BEFORE): MAP 1702E116
SCALE: NTS
OH CIRCUIT (AFTER): MAP 1702E116
UNITS OF PROPERTY
INSTALL ONLY
CROSSARMS
MATERIAL QTY
DIST. ARRESTERS
DIST. CUTOUTS
DIST. INSULATORS
TRANS. ARRESTERS
TRANS. INSULATORS
CROSSARM - DISTRIBUTION
CROSSARM - TRANSMISSION
EXISTING PROPERTY LINE
EXISTING UG RISER
NEW UG RISER
EXISTING 3Ø WIRE
EXISTING CENTER LINE
EXISTING CONDUCTOR TO BE REMOVED
DISCONNECT - FUSED
EXISTING 1Ø WIRE
EXISTING RIGHT OF WAY
EXISTING POLE
DOWN GUY
EXISTING SECONDARY SERVICE LINE
DISCONNECT - UNFUSED
SPAN GUY
NEW POLE
NEW CONDUCTOR
REMOVAL
WINGARM
EXISTING TRANSFORMER
DISCONNECT - FUSED
DISCONNECT - UNFUSED
OR
OR
OVERHEAD JUMPER CONNECTION
GANG OPERATED SWITCH
FUSESAVER W/ FUSED BYPASS
PHASE SHIFTER
STREET LIGHT
9"
3'-3"
Note:
The common neutral
height should be 10'-1"
based on single phase
tap standard 6031.5100
12 kV 10'-1"
34 kV 10'-1"
Hang fuse door at pole
Down/span guy
position ±8"of the
neutral position
Down guy position
4'-1"
X
1
2
3
4
B
P
X
1
2
3
4
F
S
FUSESAVER W/ 100T BYPASS - 6022.1061
THREE PHASE ARM MOUNT INSTALLATION (PERPENDICULAR)