HomeMy WebLinkAbout23681-M-EXH-Plot Plan-HS 75-2026-02-27CERTIFICATE OF AUTHORIZATION
CORESTATES, INC.
NO. 3132
WASHINGTON, ENGINEERING
18215 72nd Avenue South
Kent, WA 98032
855.CSG.1999
www.core-states.com
Sheet
Job Number
of
Date
Drawn
Scale
2/27/26
1"=20'
Ksumrok
Q:
\
S
h
a
r
e
d
\
P
r
o
j
e
c
t
s
I
n
t
e
g
r
a
t
i
o
n
\
B
C
E
\
A
c
t
i
v
e
\
P
r
o
j
e
c
t
s
\
2
3
0
0
0
s
\
2
3
6
8
1
\
l
o
t
\
2
3
6
8
1
-
C
E
N
T
U
R
Y
-
P
l
o
t
P
l
a
n
s
.
d
w
g
2
/
2
7
/
2
0
2
6
9
:
3
9
P
M
K
S
U
M
R
O
K
NOTE:
FLAT WORK IS SHOWN FOR ILLUSTRATIVE
PURPOSES ONLY. FINAL CONDITIONS MAY VARY.
SEPARATION NOTE:
ANY PORTIONS OF STRUCTURES WITH LESS THAN
10-FEET OF SEPARATION SHALL BE FIRE RATED.
BUILDING SETBACKS:
FRONT/GARAGE: 15' SIDE: 5' REAR: 25'=INSTALL TEMP. CONST. ENTRANCE
=INSTALL TEMP. SOIL STOCKPILE
UE =UTILITY EASEMENT
M =MODEL
P =PARKING
CLEARING NOTE:
THIS SITE HAS BEEN CLEARED WITH RECENT SITE
DEVELOPMENT OF THIS PLAT.
NO ADDITIONAL CLEARING IS PROPOSED.
NOTE:
ROOF AND FOOTING DRAINS SHALL BE TIGHTLINED
TO THE PROVIDED STORM SYSTEM AS SHOWN
PSE POWER TRANSFORMER SETBACK NOTES:
1. MINIMUM DISTANCE FROM ANY POWER
TRANSFORMER TO ANY DOOR, WINDOW, VENT,
FIRE ESCAPE OR OTHER BUILDING OPENINGS
SHALL BE 10-FEET.
2. MINIMUM DISTANCE FROM ANY POWER
TRANSFORMER TO ANY COMBUSTIBLE WALLS
OR ROOF SHALL BE 10-FEET.
STEP TANK SETBACKS
5'
2'
5'
2'
NOTE:
WHEN LOCATED IN THE YARD, THE STEP TANKS MUST BE 5'
FROM STRUCTURE AND 5' FROM PROPERTY LINE. THE STEP
TANK MUST ALSO BE 2' FROM ANY WALK OR DRIVEWAY AND
2' FROM THE 10' UE.
WHEN LOCATED IN THE DRIVEWAY, THE EDGE OF THE TANK
MAY BE ON THE 10' UE, BUT MAINTAIN 5' SETBACK FROM
STRUCTURE.
STORM DRAINAGE NOTE:
ALL DRYWELLS AND INFILTRATION TRENCHES
WERE SIZED BY SCJ ALLIANCE. PLEASE REFER TO
THE STORMWATER SITE PLAN PREPARED BY SCJ
ALLAINCE, DATED AUG 6, 2025.
TCE
TSS
SCALE: 1"=20'
0 40'20'10'
TCE
SS STUB
ROW
TSS
BSBL (TYP.)
PORCH
16' DRIVEWAY
GARAGE L
WALK
PROPOSED
CONTOUR (TYP)
FERNS LOOP SE
PUBLIC ROAD
10
'
UE
5%
M
A
X
N0
1
°
2
0
'
4
5
"
E
8
8
.
0
0
'
S88°39'15"E 50.00'
S88°39'15"E
50.00'INSTALL SILT FENCE, STRAW WATTLE, OR
FUNCTIONALLY EQUIVALENT (TYP)
RDRD
SS
N0
1
°
2
0
'
4
5
"
E
8
8
.
0
0
'
PATIO
2" PVC CONDUIT
RD
WM
SEWER SERVICE BOX
4" SS
2.0' W X 2.0' D X 30' L
INFILTRATION TRENCH
W/6" MIN. COVER
SEDIMENT CONTROL STRUCTURE
13 LF 4" DIAM. PVC
345
2'
10
'
13
'
EXISTING
CONTOUR (TYP)
APPROXIMATE LOCATION OF SEWER
STEP TANK CONTROL PANEL PLACED ON
OUTER GARAGE WALL. CONTRACTOR
TO FIELD FIT AS NEEDED.
7'
LOT LINE (TYP)
PLANTER STRIP
SIDEWALK
SSCO
SD
RD
POWER STRIKE
SUBDIVISION HOMESITE NO. 75
PARCEL NO. 84080007500
LOT ADDRESS:
9855 FERNS LOOP SE
YELM WA, 98597
LOT SIZE = 4,400 SF
IMPERVIOUS
TOTAL IMPERVIOUS: 2,180 SF (49.5%)
ROOF: 1,657 SF
DRIVEWAY: 390 SF
WALK:43 SF
PATIO:90 SF
HS 75
PROPOSED
SFR
℄
25
'
6'
6'
15.67'
5'
5'
25
'
38
.
5
'
24
.
5
'
35
'
6'
22
'
10'30'10'
344
343
342
342
TR
A
C
T
A
(O
P
E
N
S
P
A
C
E
/
D
R
A
I
N
A
G
E
)
W
EAVE
BUILDING
ENVELOPE
SS
W
18" SD
RD
UTILITY SERVICE
W
SS
SD
WATER SERVICE CONNECTION POINT
SEWER SERVICE CONNECTION POINT
STORM SERVICE CONNECTION POINT
6'x8.5' EVERGREEN PRE-CAST
CONCRETE TANK 1250 GALLON
TWO COMPARTMENT SEPTIC TANK
COVERED