HomeMy WebLinkAbout23681-M-EXH-Plot Plan-HS 09-2026-02-27CERTIFICATE OF AUTHORIZATION
CORESTATES, INC.
NO. 3132
WASHINGTON, ENGINEERING
18215 72nd Avenue South
Kent, WA 98032
855.CSG.1999
www.core-states.com
Sheet
Job Number
of
Date
Drawn
Scale
2/27/26
1"=20'
Ksumrok
Q:
\
S
h
a
r
e
d
\
P
r
o
j
e
c
t
s
I
n
t
e
g
r
a
t
i
o
n
\
B
C
E
\
A
c
t
i
v
e
\
P
r
o
j
e
c
t
s
\
2
3
0
0
0
s
\
2
3
6
8
1
\
l
o
t
\
2
3
6
8
1
-
C
E
N
T
U
R
Y
-
P
l
o
t
P
l
a
n
s
.
d
w
g
2/
2
7
/
2
0
2
6
9
:
3
9
P
M
KS
U
M
R
O
K
NOTE:
FLAT WORK IS SHOWN FOR ILLUSTRATIVE
PURPOSES ONLY. FINAL CONDITIONS MAY VARY.
SEPARATION NOTE:
ANY PORTIONS OF STRUCTURES WITH LESS THAN
10-FEET OF SEPARATION SHALL BE FIRE RATED.
BUILDING SETBACKS:
FRONT/GARAGE: 15' SIDE: 5' REAR: 25'=INSTALL TEMP. CONST. ENTRANCE
=INSTALL TEMP. SOIL STOCKPILE
UE =UTILITY EASEMENT
M =MODEL
P =PARKING
CLEARING NOTE:
THIS SITE HAS BEEN CLEARED WITH RECENT SITE
DEVELOPMENT OF THIS PLAT.
NO ADDITIONAL CLEARING IS PROPOSED.
NOTE:
ROOF AND FOOTING DRAINS SHALL BE TIGHTLINED
TO THE PROVIDED STORM SYSTEM AS SHOWN
PSE POWER TRANSFORMER SETBACK NOTES:
1.MINIMUM DISTANCE FROM ANY POWER
TRANSFORMER TO ANY DOOR, WINDOW, VENT,
FIRE ESCAPE OR OTHER BUILDING OPENINGS
SHALL BE 10-FEET.
2.MINIMUM DISTANCE FROM ANY POWER
TRANSFORMER TO ANY COMBUSTIBLE WALLS
OR ROOF SHALL BE 10-FEET.
STEP TANK SETBACKS
5'
2'
5'
2'
NOTE:
WHEN LOCATED IN THE YARD, THE STEP TANKS MUST BE 5'
FROM STRUCTURE AND 5' FROM PROPERTY LINE. THE STEP
TANK MUST ALSO BE 2' FROM ANY WALK OR DRIVEWAY AND
2' FROM THE 10' UE.
WHEN LOCATED IN THE DRIVEWAY, THE EDGE OF THE TANK
MAY BE ON THE 10' UE, BUT MAINTAIN 5' SETBACK FROM
STRUCTURE.
STORM DRAINAGE NOTE:
ALL DRYWELLS AND INFILTRATION TRENCHES
WERE SIZED BY SCJ ALLIANCE. PLEASE REFER TO
THE STORMWATER SITE PLAN PREPARED BY SCJ
ALLAINCE, DATED AUG 6, 2025.
TCE
TSS
SCALE: 1"=20'
0 40'20'10'
TCE
SS STUB
ROW
TSS
BSBL (TYP.)
PORCH 16' DRIVEWAY
GARAGE R
WALK
EXISTING
CONTOUR (TYP)
FERNS LOOP SE
PUBLIC ROAD
10
'
UE
5%
M
A
X
N88°23'25"W 50.00'
S88°39'15"E
38.86'
INSTALL SILT FENCE, STRAW
WATTLE, OR FUNCTIONALLY
EQUIVALENT (TYP)
RDRD
SS
COVERED
PATIO
2" PVC
CONDUIT
RD
WMSEWER SERVICE BOX
2.0' W X 2.0' D X 30' L
INFILTRATION TRENCH
W/6" MIN. COVER
SEDIMENT CONTROL
STRUCTURE
13 LF 4" DIAM. PVC
2'
10
'
13
.
0
4
'
PROPOSED
CONTOUR (TYP)
APPROXIMATE LOCATION OF SEWER
STEP TANK CONTROL PANEL PLACED ON
OUTER GARAGE WALL. CONTRACTOR
TO FIELD FIT AS NEEDED.
7'
LOT LINE (TYP)
SERVICE LINE SHALL BE SLEEVED UNDER
DRIVEWAYS, SIDEWALKS AND WHERE
THE SERVICE LINE CAN MAKE CONTACT
WITH ANY PART OF THE TANK.
SSCO
SD
RD POWER STRIKE
SUBDIVISION HOMESITE NO. 9
PARCEL NO. 84080000900
LOT ADDRESS:
9854 FERNS LOOP SE
YELM WA, 98597
LOT SIZE = 4,398 SF
IMPERVIOUS
TOTAL IMPERVIOUS: 2,179 SF (49.5%)
ROOF:1,764 SF
DRIVEWAY:374 SF
WALK:41 SF
PATIO:0 SF
HS 9
PROPOSED
SFR
℄
10'30'10'
343
342
342
W
EAVE
BUILDING
ENVELOPE
SS
8" W
12'x5' ROTH MULTITANK®
1250 GALLON STEP TANK
MODEL RMT-1250
RD
S0
1
°
2
0
'
4
5
"
W
8
8
.
5
3
'
S0
1
°
2
0
'
4
5
"
W
87
.
8
2
'
RD
J-BOX
UTILITY SERVICE
W
SS
SD
WATER SERVICE CONNECTION POINT
SEWER SERVICE CONNECTION POINT
STORM SERVICE CONNECTION POINT
PLAT BOUNDARY (TYP)
LUMINARE
W
L=11.16'
R=128.00'
Δ=04°59'39"
34
4
24
.
9
8
'
5'
5'
5'
5'5'
5'
25
.
2
1
'
40
'
23
.
3
3
'
7.
5
'
27
.
5
'
5'
22
.
8
4
'
10' VACATED
FLUME LANE
TRANSFORMER
SS