Loading...
HomeMy WebLinkAbout23681-M-EXH-Plot Plan-HS 09-2026-02-27CERTIFICATE OF AUTHORIZATION CORESTATES, INC. NO. 3132 WASHINGTON, ENGINEERING 18215 72nd Avenue South Kent, WA 98032 855.CSG.1999 www.core-states.com Sheet Job Number of Date Drawn Scale 2/27/26 1"=20' Ksumrok Q: \ S h a r e d \ P r o j e c t s I n t e g r a t i o n \ B C E \ A c t i v e \ P r o j e c t s \ 2 3 0 0 0 s \ 2 3 6 8 1 \ l o t \ 2 3 6 8 1 - C E N T U R Y - P l o t P l a n s . d w g 2/ 2 7 / 2 0 2 6 9 : 3 9 P M KS U M R O K NOTE: FLAT WORK IS SHOWN FOR ILLUSTRATIVE PURPOSES ONLY. FINAL CONDITIONS MAY VARY. SEPARATION NOTE: ANY PORTIONS OF STRUCTURES WITH LESS THAN 10-FEET OF SEPARATION SHALL BE FIRE RATED. BUILDING SETBACKS: FRONT/GARAGE: 15' SIDE: 5' REAR: 25'=INSTALL TEMP. CONST. ENTRANCE =INSTALL TEMP. SOIL STOCKPILE UE =UTILITY EASEMENT M =MODEL P =PARKING CLEARING NOTE: THIS SITE HAS BEEN CLEARED WITH RECENT SITE DEVELOPMENT OF THIS PLAT. NO ADDITIONAL CLEARING IS PROPOSED. NOTE: ROOF AND FOOTING DRAINS SHALL BE TIGHTLINED TO THE PROVIDED STORM SYSTEM AS SHOWN PSE POWER TRANSFORMER SETBACK NOTES: 1.MINIMUM DISTANCE FROM ANY POWER TRANSFORMER TO ANY DOOR, WINDOW, VENT, FIRE ESCAPE OR OTHER BUILDING OPENINGS SHALL BE 10-FEET. 2.MINIMUM DISTANCE FROM ANY POWER TRANSFORMER TO ANY COMBUSTIBLE WALLS OR ROOF SHALL BE 10-FEET. STEP TANK SETBACKS 5' 2' 5' 2' NOTE: WHEN LOCATED IN THE YARD, THE STEP TANKS MUST BE 5' FROM STRUCTURE AND 5' FROM PROPERTY LINE. THE STEP TANK MUST ALSO BE 2' FROM ANY WALK OR DRIVEWAY AND 2' FROM THE 10' UE. WHEN LOCATED IN THE DRIVEWAY, THE EDGE OF THE TANK MAY BE ON THE 10' UE, BUT MAINTAIN 5' SETBACK FROM STRUCTURE. STORM DRAINAGE NOTE: ALL DRYWELLS AND INFILTRATION TRENCHES WERE SIZED BY SCJ ALLIANCE. PLEASE REFER TO THE STORMWATER SITE PLAN PREPARED BY SCJ ALLAINCE, DATED AUG 6, 2025. TCE TSS SCALE: 1"=20' 0 40'20'10' TCE SS STUB ROW TSS BSBL (TYP.) PORCH 16' DRIVEWAY GARAGE R WALK EXISTING CONTOUR (TYP) FERNS LOOP SE PUBLIC ROAD 10 ' UE 5% M A X N88°23'25"W 50.00' S88°39'15"E 38.86' INSTALL SILT FENCE, STRAW WATTLE, OR FUNCTIONALLY EQUIVALENT (TYP) RDRD SS COVERED PATIO 2" PVC CONDUIT RD WMSEWER SERVICE BOX 2.0' W X 2.0' D X 30' L INFILTRATION TRENCH W/6" MIN. COVER SEDIMENT CONTROL STRUCTURE 13 LF 4" DIAM. PVC 2' 10 ' 13 . 0 4 ' PROPOSED CONTOUR (TYP) APPROXIMATE LOCATION OF SEWER STEP TANK CONTROL PANEL PLACED ON OUTER GARAGE WALL. CONTRACTOR TO FIELD FIT AS NEEDED. 7' LOT LINE (TYP) SERVICE LINE SHALL BE SLEEVED UNDER DRIVEWAYS, SIDEWALKS AND WHERE THE SERVICE LINE CAN MAKE CONTACT WITH ANY PART OF THE TANK. SSCO SD RD POWER STRIKE SUBDIVISION HOMESITE NO. 9 PARCEL NO. 84080000900 LOT ADDRESS: 9854 FERNS LOOP SE YELM WA, 98597 LOT SIZE = 4,398 SF IMPERVIOUS TOTAL IMPERVIOUS: 2,179 SF (49.5%) ROOF:1,764 SF DRIVEWAY:374 SF WALK:41 SF PATIO:0 SF HS 9 PROPOSED SFR ℄ 10'30'10' 343 342 342 W EAVE BUILDING ENVELOPE SS 8" W 12'x5' ROTH MULTITANK® 1250 GALLON STEP TANK MODEL RMT-1250 RD S0 1 ° 2 0 ' 4 5 " W 8 8 . 5 3 ' S0 1 ° 2 0 ' 4 5 " W 87 . 8 2 ' RD J-BOX UTILITY SERVICE W SS SD WATER SERVICE CONNECTION POINT SEWER SERVICE CONNECTION POINT STORM SERVICE CONNECTION POINT PLAT BOUNDARY (TYP) LUMINARE W L=11.16' R=128.00' Δ=04°59'39" 34 4 24 . 9 8 ' 5' 5' 5' 5'5' 5' 25 . 2 1 ' 40 ' 23 . 3 3 ' 7. 5 ' 27 . 5 ' 5' 22 . 8 4 ' 10' VACATED FLUME LANE TRANSFORMER SS