HomeMy WebLinkAboutSM01 Site PlanRD RD
SD
SD
SD
RD RD
RD RD
RD
RD
RD
RD RD
SD
SD
SD SD
SD SD
SD
SD
SD
SD
SD
SD
SD
SD SD
SD SD SDSDSDSDSDSD
RD RDRDRD
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
SS
W
W
W
W
W
W
W
W W W W W W W W W W W W W W
W
W
W
W
W W
W
RD
SD SD SD SD
C C C C C C C C C C C C C C C C CCCC
FI
L
E
N
A
M
E
:
Z:
\
P
\
S
M
0
1
\
C
A
D
\
S
h
e
e
t
s
\
S
M
0
1
P
r
e
l
i
m
i
n
a
r
y
S
i
t
e
P
l
a
n
.
d
w
g
D
A
T
E
/
T
I
M
E
:
4/
9
/
2
0
2
6
3
:
5
6
:
3
6
P
M
SI
T
E
P
L
A
N
PR
O
P
O
S
E
D
I
N
D
O
O
R
AT
H
L
E
T
I
C
F
A
C
I
L
I
T
Y
NDT
WRK
04-09-2026
SM01
NDT
C1
1 1
SCALE IN FEETSCALE IN FEET
30150 45 60
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
A
B
C
D
E
F
G
H
I
J
3
6
0
-
8
9
0
-
8
9
5
5
|
2
9
9
N
M
a
r
k
e
t
B
l
v
d
,
C
h
e
h
a
l
i
s
,
W
A
9
8
5
3
2
DESIGNED BY:
DRAWN BY:
DATE:
PROJ. NO:
OF
REVIEWED BY:
Know what's BELOW
Call 811 before you dig.
NICHOLAS DA VID AYLORSTATEOFWASHINGTON
REGIS TERED
PROFESSIONAL ENGINEER
T
4611304/
0
9
/
2
0
2
6
100'
70
'
50'
75
'
5'
5'
10'
YE
L
M
A
V
E
S
E
NW CULLENS RD
VICINITY MAP
NOT TO SCALE
KEY NOTES
1.PROPOSED 7,000 SF INDOOR ATHLETIC FACILITY (TYP)
2.PROPOSED 3,750 SF OFFICE / ADMINISTRATION BUILDING
3.PROPOSED CONCRETE WALKWAY
4.PROPOSED PAVED PARKING AREA
5.PROPOSED LANDSCAPING PER SEPARATE LANDSCAPING PLAN (TYP)
6.PROPOSED REFUSE AND RECYCLING AREA
7.PROPOSED 31' DRIVEWAY
8.PROPOSED 5' PUBLIC SIDEWALK
9.PROPOSED 53' ACCESS EASEMENT
10.PROPOSED SANITARY SEWER LATERAL
11.PROPOSED PRIVATE SANITARY SEWER MANHOLE (TYP)
12.PROPOSED CONNECTION TO EXISTING SANITARY SEWER
13.PROPOSED WATER MAIN LOOP EXTENSION
14.PROPOSED WATER SERVICE LATERAL
15.PROPOSED 6" ROOF DRAIN PIPING
16.PROPOSED 6" STORM DRAIN PIPING
17.PROPOSED STORMWATER CLEANOUT
18.PROPOSED TYPE 1 CB WITH LOCKING VANED GRATE (TYP)
19.PROPOSED STORMWATER TREATMENT TYPE 2 CB WITH MANHOLE
20.PROPOSED TYPE 2 CB WITH SOLID LOCKING LID
21.PROPOSED STORMWATER INFILTRATION GALLERY
22.PROPOSED 90° STANDARD PARKING STALL (TYP)
23.PROPOSED 60° STANDARD PARKING STALL (TYP)
24.PROPOSED 60° COMPACT PARKING STALL (TYP)
25.PROPOSED 60° ACCESSIBLE STALL (TYP)
26.PROPOSED 60° VAN ACCESSIBLE STALL
27.PROPOSED CROSSWALK (TYP)
28.PROPOSED 10' TALL 36 SF ELECTRONIC FREE STANDING SIGN
29.PROPOSED 6' TALL 51 SF MONUMENT SIGN
30.EXISTING ROW LINE
31.EXISTING ROW LINE AFTER 5' DEDICATION
32.EXISTING SIDEWALK
33.EXISTING DENTAL OFFICE
34.EXISTING DENTAL OFFICE PARKING LOT
35.PROPOSED BOUNDARY LINE AFTER ADJUSTMENT
#
·EXISTING HARD SURFACE: 0 SF
·NEW HARD SURFACE (ROOF):31,750 SF
·NEW HARD SURFACE (OTHER):70,220 SF
·TOTAL NEW PLUS REPLACED HARD SURFACE:101,970 SF
·TOTAL HARD SURFACE AFTER PROJECT:101,970 SF
·NEW POLLUTION GENERATING HARD SURFACE:57,218 SF
·PROPOSED EFFECTIVE HARD SURFACE:0 SF
·DISTURBED AREA 120,916 SF
SITE COVERAGE DATA (WITHIN LOD)
SITE DATA
PARCEL #:21724140900, 21724141001
SITE ADDRESS: 718 YELM AVE W & 209 CULLENS ST SE
YELM, WA 98597
GROSS ACREAGE: 2.78 AC
ZONING:C-1
EXISTING USE: COMMERCIAL, VACANT
PRESIDING JURISDICTION:YELM, WA
EXISTING FEATURES ARE APPROXIMATELY AS DEPICTED IN A TOPOGRAPHIC
AND BOUNDARY SURVEY PREPARED BY BUTLER SURVEYING INC., DATED
7/25/25. ALL EXISTING FEATURES AND TOPOGRAPHY SHOWN SHALL BE
VERIFIED AT CONTRACTOR'S EXPENSE PRIOR TO BEGINNING CONSTRUCTION.
ANY AND ALL DISCREPANCIES FOUND BETWEEN ACTUAL EXISTING
CONDITIONS AND THE EXISTING CONDITIONS SHOWN HERE SHALL BE
IDENTIFIED TO THE PROJECT ENGINEER PRIOR TO CONTINUANCE OF ANY
WORK.
BASIS OF BEARINGS: WASHINGTON STATE PLANE SOUTH ZONE (NAD 83/2011)
DERIVED FROM TIES TO THURSTON COUNTY CONTROL POINTS #1252TBM AND
#253. HELD THE PUBLISHED COORDINATE AT "1252TBM" AND APPLIED THE
COMBINED SCALE FACTOR OF 0.999921334 TO PRODUCE THE GROUND
DISTANCES DEPICTED HEREON.
BASIS OF ELEVATIONS: NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88)
RELATIVE TO THURSTON COUNTY CONTROL POINT #1252TBM HAVING A
PUBLISHED ELEVATION OF 349.818' (NAVD 88).
EXISTING CONDITIONS
SITE
31'
18.6'
53
'
1
2
3
4
5
6
7
5'
8
9
10
11
12
13
14
15
16
17
18
19
20
21
32
33
34
EXISTING
COMMERCIAL
BUILDING
PROPOSED
INDOOR ATHLETIC
FACILITY
PROPOSED
INDOOR ATHLETIC
FACILITY
PROPOSED
INDOOR ATHLETIC
FACILITY
PROPOSED
INDOOR ATHLETIC
FACILITY
PR
O
P
O
S
E
D
OF
F
I
C
E
/
MU
L
T
I
P
U
R
P
O
S
E
BU
I
L
D
I
N
G
23
24
22
'
8.5'
18
'18
'
23'23'
7.6'5'
5'
8.
5
'
20'
5'
5'
6.
7
'
5'
5'
20'
10
'
5'
10'
20.4'
23
'
30
'
25
'
17
'
18'
9.2
'
23.1
'
8.7'
2625
22
27
28
29
31
30
REQUIRED STALLS:172
PROPOSED STANDARD STALLS:152
PROPOSED COMPACT STALLS:20
*TOTAL PROPOSED STALLS:172
*INCLUDES 6 ACCESSIBLE STALLS,
ONE OF WHICH IS VAN ACCESSIBLE
PARKING
35
35