Loading...
HomeMy WebLinkAboutSM01 Site PlanRD RD SD SD SD RD RD RD RD RD RD RD RD RD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SD SDSDSDSDSDSD RD RDRDRD SS SS SS SS SS SS SS SS SS SS SS W W W W W W W W W W W W W W W W W W W W W W W W W W W W RD SD SD SD SD C C C C C C C C C C C C C C C C CCCC FI L E N A M E : Z: \ P \ S M 0 1 \ C A D \ S h e e t s \ S M 0 1 P r e l i m i n a r y S i t e P l a n . d w g D A T E / T I M E : 4/ 9 / 2 0 2 6 3 : 5 6 : 3 6 P M SI T E P L A N PR O P O S E D I N D O O R AT H L E T I C F A C I L I T Y NDT WRK 04-09-2026 SM01 NDT C1 1 1 SCALE IN FEETSCALE IN FEET 30150 45 60 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 A B C D E F G H I J 3 6 0 - 8 9 0 - 8 9 5 5 | 2 9 9 N M a r k e t B l v d , C h e h a l i s , W A 9 8 5 3 2 DESIGNED BY: DRAWN BY: DATE: PROJ. NO: OF REVIEWED BY: Know what's BELOW Call 811 before you dig. NICHOLAS DA VID AYLORSTATEOFWASHINGTON REGIS TERED PROFESSIONAL ENGINEER T 4611304/ 0 9 / 2 0 2 6 100' 70 ' 50' 75 ' 5' 5' 10' YE L M A V E S E NW CULLENS RD VICINITY MAP NOT TO SCALE KEY NOTES 1.PROPOSED 7,000 SF INDOOR ATHLETIC FACILITY (TYP) 2.PROPOSED 3,750 SF OFFICE / ADMINISTRATION BUILDING 3.PROPOSED CONCRETE WALKWAY 4.PROPOSED PAVED PARKING AREA 5.PROPOSED LANDSCAPING PER SEPARATE LANDSCAPING PLAN (TYP) 6.PROPOSED REFUSE AND RECYCLING AREA 7.PROPOSED 31' DRIVEWAY 8.PROPOSED 5' PUBLIC SIDEWALK 9.PROPOSED 53' ACCESS EASEMENT 10.PROPOSED SANITARY SEWER LATERAL 11.PROPOSED PRIVATE SANITARY SEWER MANHOLE (TYP) 12.PROPOSED CONNECTION TO EXISTING SANITARY SEWER 13.PROPOSED WATER MAIN LOOP EXTENSION 14.PROPOSED WATER SERVICE LATERAL 15.PROPOSED 6" ROOF DRAIN PIPING 16.PROPOSED 6" STORM DRAIN PIPING 17.PROPOSED STORMWATER CLEANOUT 18.PROPOSED TYPE 1 CB WITH LOCKING VANED GRATE (TYP) 19.PROPOSED STORMWATER TREATMENT TYPE 2 CB WITH MANHOLE 20.PROPOSED TYPE 2 CB WITH SOLID LOCKING LID 21.PROPOSED STORMWATER INFILTRATION GALLERY 22.PROPOSED 90° STANDARD PARKING STALL (TYP) 23.PROPOSED 60° STANDARD PARKING STALL (TYP) 24.PROPOSED 60° COMPACT PARKING STALL (TYP) 25.PROPOSED 60° ACCESSIBLE STALL (TYP) 26.PROPOSED 60° VAN ACCESSIBLE STALL 27.PROPOSED CROSSWALK (TYP) 28.PROPOSED 10' TALL 36 SF ELECTRONIC FREE STANDING SIGN 29.PROPOSED 6' TALL 51 SF MONUMENT SIGN 30.EXISTING ROW LINE 31.EXISTING ROW LINE AFTER 5' DEDICATION 32.EXISTING SIDEWALK 33.EXISTING DENTAL OFFICE 34.EXISTING DENTAL OFFICE PARKING LOT 35.PROPOSED BOUNDARY LINE AFTER ADJUSTMENT # ·EXISTING HARD SURFACE: 0 SF ·NEW HARD SURFACE (ROOF):31,750 SF ·NEW HARD SURFACE (OTHER):70,220 SF ·TOTAL NEW PLUS REPLACED HARD SURFACE:101,970 SF ·TOTAL HARD SURFACE AFTER PROJECT:101,970 SF ·NEW POLLUTION GENERATING HARD SURFACE:57,218 SF ·PROPOSED EFFECTIVE HARD SURFACE:0 SF ·DISTURBED AREA 120,916 SF SITE COVERAGE DATA (WITHIN LOD) SITE DATA PARCEL #:21724140900, 21724141001 SITE ADDRESS: 718 YELM AVE W & 209 CULLENS ST SE YELM, WA 98597 GROSS ACREAGE: 2.78 AC ZONING:C-1 EXISTING USE: COMMERCIAL, VACANT PRESIDING JURISDICTION:YELM, WA EXISTING FEATURES ARE APPROXIMATELY AS DEPICTED IN A TOPOGRAPHIC AND BOUNDARY SURVEY PREPARED BY BUTLER SURVEYING INC., DATED 7/25/25. ALL EXISTING FEATURES AND TOPOGRAPHY SHOWN SHALL BE VERIFIED AT CONTRACTOR'S EXPENSE PRIOR TO BEGINNING CONSTRUCTION. ANY AND ALL DISCREPANCIES FOUND BETWEEN ACTUAL EXISTING CONDITIONS AND THE EXISTING CONDITIONS SHOWN HERE SHALL BE IDENTIFIED TO THE PROJECT ENGINEER PRIOR TO CONTINUANCE OF ANY WORK. BASIS OF BEARINGS: WASHINGTON STATE PLANE SOUTH ZONE (NAD 83/2011) DERIVED FROM TIES TO THURSTON COUNTY CONTROL POINTS #1252TBM AND #253. HELD THE PUBLISHED COORDINATE AT "1252TBM" AND APPLIED THE COMBINED SCALE FACTOR OF 0.999921334 TO PRODUCE THE GROUND DISTANCES DEPICTED HEREON. BASIS OF ELEVATIONS: NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD 88) RELATIVE TO THURSTON COUNTY CONTROL POINT #1252TBM HAVING A PUBLISHED ELEVATION OF 349.818' (NAVD 88). EXISTING CONDITIONS SITE 31' 18.6' 53 ' 1 2 3 4 5 6 7 5' 8 9 10 11 12 13 14 15 16 17 18 19 20 21 32 33 34 EXISTING COMMERCIAL BUILDING PROPOSED INDOOR ATHLETIC FACILITY PROPOSED INDOOR ATHLETIC FACILITY PROPOSED INDOOR ATHLETIC FACILITY PROPOSED INDOOR ATHLETIC FACILITY PR O P O S E D OF F I C E / MU L T I P U R P O S E BU I L D I N G 23 24 22 ' 8.5' 18 '18 ' 23'23' 7.6'5' 5' 8. 5 ' 20' 5' 5' 6. 7 ' 5' 5' 20' 10 ' 5' 10' 20.4' 23 ' 30 ' 25 ' 17 ' 18' 9.2 ' 23.1 ' 8.7' 2625 22 27 28 29 31 30 REQUIRED STALLS:172 PROPOSED STANDARD STALLS:152 PROPOSED COMPACT STALLS:20 *TOTAL PROPOSED STALLS:172 *INCLUDES 6 ACCESSIBLE STALLS, ONE OF WHICH IS VAN ACCESSIBLE PARKING 35 35