Loading...
HomeMy WebLinkAboutPlotPlan_YRR-000-00-018_16312-JenkinsAveSERD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RDRDRDRDRDRDRDRD RD RD RD RD RD RD RD RD RD 20 . 0 0 GARAGE CLEANOUT ROOF LINE EX. SEWER PROPOSED CONTOUR PROPOSED TREE GF: 340.4 FF: 340.9 25 . 0 0 15 . 0 0 PATIO SEWER STUB WATER METER PORCH EX. STORM EX. RECLAIMED WATER EX. WATER CONNECT TO STORM PIPE STORM CLEANOUT ROOF DRAIN LINE LOT 19 GAS METER CONTROL PANEL ELECTRIC METER JENKINS AVE SE 5' 25 . 0 0 5' BSBL 25 ' B S B L 5' BSBL 15 ' B S B L 8.83' 342 5' 5' 20 ' G A R A G E 20.5' 5' 10' P.U.E. & S.D.E. 40' 42' 50 ' LOT 17 LOT 18 4,500± SF 4.84' N52°28'39"E 50.00 N3 7 ° 3 1 ' 2 1 " W 9 0 . 0 0 N52°28'39"E 50.00 N3 7 ° 3 1 ' 2 1 " W 9 0 . 0 0 340 RMT 1250 STEP TANK SLEEVE 4/7/2026 8:09 AM CFEMLING J:\2025\25103\PLOT PLANS\LOT 18.DWG SITE 25103 DESIGN 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING SURVEYING LEGEND P.U.E.PUBLIC UTILITY EASEMENT S.D.E.PRIVATE STORM DRAIN EASEMENT NOTE NO FOOTING DRAINS USED DUE TO INFILTRATION DIRECTLY INTO THE GROUND. CONCRETE PAD LOT 18 1431 BAINBRIDGE 4/7/26 AREAS 16312 JENKINS AVE SE SITE AND UTILITY PLAN ADDRESS:16312 JENKINS AVE SE LOT#:18 PROJECT#: PERMIT#: RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RD RDRDRDRDRDRDRDRD RD RD RD RD RD RD RD RD RD 20 . 0 0 GARAGE CLEANOUT ROOF LINE EX. SEWER PROPOSED CONTOUR PROPOSED TREE GF: 340.4 FF: 340.9 25 . 0 0 15 . 0 0 PATIO SEWER STUB WATER METER PORCH EX. STORM EX. RECLAIMED WATER EX. WATER CONNECT TO STORM PIPE STORM CLEANOUT ROOF DRAIN LINE LOT 19 JENKINS AVE SE 5' 25 . 0 0 5' BSBL 25 ' B S B L 5' BSBL 15 ' B S B L 342 5' 5' 20 ' G A R A G E 20.5' 5' 10' P.U.E. & S.D.E. 40' 42' 50 ' LOT 17 LOT 18 4,500± SF 4.84' N52°28'39"E 50.00 N3 7 ° 3 1 ' 2 1 " W 9 0 . 0 0 N52°28'39"E 50.00 N3 7 ° 3 1 ' 2 1 " W 9 0 . 0 0 340 RMT 1250 STEP TANK SLEEVE 4/7/2026 8:09 AM CFEMLING J:\2025\25103\PLOT PLANS\LOT 18.DWG TESC 25103 DESIGN 12100 NE 195th St, Suite 300 Bothell, Washington 98011 425.885.7877 CIVIL ENGINEERING LANDSCAPE ARCHITECTURE PLANNING SURVEYING LEGEND P.U.E.PUBLIC UTILITY EASEMENT S.D.E.PRIVATE STORM DRAIN EASEMENT NOTE NO FOOTING DRAINS USED DUE TO INFILTRATION DIRECTLY INTO THE GROUND. CONCRETE PAD LOT 18 4/7/26 TESC PLAN CONTRACTOR SHALL INSTALL SILT FENCE USING BEST MANAGEMENT PRACTICESALL OPEN AREAS SHALL BE COVERED WITH MULCH, THICK STRAW, OR PLASTIC SHEETING TEMPORARY CONSTRUCTION ENTRANCE 1431 BAINBRIDGE 16312 JENKINS AVE SE