Loading...
20100207 Permit Pkg 10292010City of Yelm Community Development Department Building Division Phone: (360) 458-8407 Fax: (360) 458-3144 Applicant: Name: YELM MEDICAL OFFICE BUILDING Address: 2840 CRITES ST W TUMWATER WA 98512 Property Information: site Address: 201 TAHOMA BLVD SE Permit No.: 20100207 Issue Date: 10/29/2010 (Work must be completed within 180 days) Phone: 360-292-7850 (1 Owner: YELM MEDICAL OFFICE BLDG. LLC Assessor Parcel No.: 2 1 7241 30602 Subdivision: Contractor Information Lot: Name: SMITH FIRE SYSTEMS Phone: 253-926-1880 Address: 1106 54TH AVE. SE TACOMA WA 98424 Contractor License No.: SMITHFS1360T Expires: 11/02/2010 Project Information: Project: FIRE SPRINKLER Description of Work: PROVICENCE IMAGING TI FIRE SPRINKLER Sq. Ft. per floor: First Heat Type (Electric, Gas, Other): Second Third Garage Basement Fees: Item FIRE SPRINK Contractor SMITH FIRE SYSTEMS TOTAL FEES: Fees $ 183.56 5 183.56 OFFICIAL USE ONLY # Sets of Prints: Final Inspection: Date: sy: Applicant's Affidavit: I certify that I have read and examined the information contained within the application and know the same to be true and correct. I also certify that the proposed structure is in conformity with all applicable City of Yelm regulations including those governing zoning and land subdivision, and in addition, all covenants, easements and restrictions of record. If applying as a contractor, I further certify that I am currently ~i~~ of Y~1« ~'~F,G:~ 458-840L FtEG'~: ~?~('4:~S1G 1Ci?'~'~~1.0 ~:D~ F;~ QPER: ro TERi~: ~Oi REF'S: ?B~GI TR~i~: ;~.~.000~? £~I IILI~I~IG F'E~~IT ~OlOQ?07 i8:~,.5~L~CF; YEEi~ MEDIrAt nFFICE BIJII.DI~'C 4ql TAFII~iA RLUD 5E FIRE SPRi~i:: 183.~aE~CR TENDERED: _le~.5~~ Ci~fCK ~i~~±i,E: il,lt~ CITY OF YELM COMMERCIAL BUILDING PERMIT APPLICATION FORM Project Address: dol Ta>ho,x.a_. ~\vd Ssi, t~21r. , U ~ Parcel #: at~~N i3o(poo ~.17a4 i3o5-o0, ~,1't~-N 13o(y0a Zoning; Current Use: 54.21\ coact Proposed Use: r1r~~c~l ~o~k~c~ ^ New Construction ~ Re-Model / Re-Roof /Tenant Improvement Plumbing ~ Mechanical ,4 Fire Prevent/Suppress/Alarm Other Project Description/Scope of Work: Wtod;.ly er~5~',na S~n~-lec s~~tP.n ~ n-c~ +e~t sta~ac°.~ Project Value: ~ LI I G3 • "O Building Area (sq. ft) Parking Garage~1 S' Floor I~, 35 2~d Floor_~3`~ Floor~_ Building Height Are there any environmentally sensitive areas located on the parcel? _ completed environmental checklist must accompany permit application. If yes, a BUILDING OWNER/TENANT NAME:pco ~ R t ADDRESS LIIU So~~t-vl ~ v.b2c ~~ _E AIL ~ohec^~.~ake~ ~~ov~de..cc .oc`a~ CITY- ('f.~-c-t.:\:~ STATE~4 _.ZIP ~XS31 TELEPHONE (3~) '3-so- 38c~8 ARGHITECT/ENGINEER LICENSE # ADDRESS EMAIL CITY STATE ZIP TELEPHONE GENERACCONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE_CITY LICENSE # PLUMBING CONTRACTOR TELEPHONE ADDRESS EMAIL CITY STATE ZIP FAX CONTRACTOR'S LICENSE # EXP DATE_CITY LICENSE # MECHANICAL CONTRACTOR ~rn',~-In F'„csysk.~s TELEPHONE (~-ss)~-Ng-~yl ADDRESS - +!~ EMAIL axe-lso+t+t ~' sue;-w~~;rC . ~d~ CITY ~Ta~,w~a. _STATE A ZIP ~gl/~1y FAX. (.~s3)~9~v-i~lrv CONTRACTOR'S LICENSE # Sw~1µF5 i3woT EXP DATE CITY LICENSE # Copy of City Mitigation documentation (TFC). I hereby certify that the above information is correct and that the construction on, and the occupancy and the use of the above described property will be in accordance with the laws, rules and regulations of the State of Washington and the City of Yelm. G~ %~ /D -/y-/a Applicant's Signature Date Owner /Contractor /Owner's Agent /Contractor's Agent /Tenant (Please circle one.) All permits are non-transferable and will expire if work authorized by such permit is not begun within 180 days of issuance, or if work is suspended or abandoned for a period of 180 days 105 Yelm Avenue PD $ox 479 Yelm, WA 98597 (360) 458-3144 FAX www.ci.yelm.wa.us FILE C':' Bulletin 014 Rev. D ~~';~~'~ Model F1 FR Series Quick Response Standard Spray Model F1 FR 56 Sprinkler Types Standard Upright Standard Pendent Conventional Vertical Sidewall Horizontal Sidewall Model F1 FR 56 Recessed Sprinkler Types Standard Pendent/F1/F21FP Horizontal Sidewall Model F1 FR 56 Concealed Sprinkler Types Standard Pendent Listing & Approvals 1. Underwriters Laboratories Inc. and Certified for Canada (cULus). 2. Factory Mutual Approvals (FM) 3. Loss Prevention Councii (LPCB, Uf<) 4. VdS Schadenverhutung GmbH UL Listing Category Sprinklers, Automatic & Open (VNIV) Quick Response Sprinkler Product Description Reliable Models F1FR Series Sprinklers are quick re- sponse sprinklers which combine the durability of a stan- dard sprinkler with the attractive low profile of a decorative sprinkler. The Models F1FR Series Recessed automatic sprinklers utilize a 3,0 mm frangible glass bulb. These sprinklers have demonstrated response times in laboratory tests which are five to ten times faster than standard response sprin- klers. This quick response enables the Model F1FR Series sprinklers to apply water to a fire much faster than standard sprinklers of the same temperature rating. The glass bulb consists of an accurately controlled amount of special fluid hermetically sealed inside a precisely manu- factured glass capsule, This glass bulb is specially con- structed to provide fast thermal response. At normal temperatures, the glass bulb contains the fluid in both the liquid and vapor phases. The vapor phase can be seen as a small bubble. As heat is applied, the liquid expands, forcing the bubble smaller and smaller as the liq- uid pressure increases. Continued heating forces the liquid to push out against the bulb, causing the glass to shatter, opening the waterway and allowing the deflector to distrib- ute the discharging water. ,.,~,_ ~: •-„~ n `~~"_ ~ ~~~~v II Vertical Sidewall Conventional Horizontal Sidewall Recessed Pendent/F1/F2 ~: ,~~ ! ~~ ', ,~ Recessed Recessed Horizontal Sidewall Pendent/FP Application Quick response sprinklers are used in fixed fire protec- tion systems: Wet, Dry, Deluge or Preaction. Care must be exercised that the orifice size, temperature rating, deflec- tor style and sprinkler type are in accordance with the lat- est published standards of the National Fire Protection As- sociation or the approving Authority Having Jurisdiction. Quick response sprinklers are intended for installation as specified in NFPA 13. Quick response sprinklers and stan- dard response sprinklers should not be intermixed. 0 0 The Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 Model F1 FR Quick Response Upright, Pendent & Conventional Sprinklers Installation Wrench: Model D Sprinkler Wrench Installation Data: Nominal Thread Nominal K Factor Orifice Size -! -_~ ___ _ US Metric Standard-Upright (SSU) and pend ''/z" (15mm) '/z" NPT(R'/z) 5.6 80 Conventional-Install in 15mm"' ''/a" NPT(F~'/z) 5-6 ~80 "' cULus Listed corrosion resistant (Polyester coated) sprinkler '7' Polyester coaled FM approved sprinkler. .,. '~ '#~ Upright Pendent Model F1 FR 56 Quick Response Recessed Pendent Sprinkler Installation Wrench: Model GFR2 Sprinkler Wrench Installation Data: _ _ Nominal Thread K Factor Sprinkler Sprinkler Identification Number ._- Orifice ~ Size US ~ Metric Height (SIN) - - ___ ''/z" (15mm) '/z" NPT(R'/z) 5.6 80 2.25" (57mm) RA1414 "' Reter to escutcheon data table for approvals and dimensions. 1 I/1' HOLE WA- f571mmJ 1 IS/16" 0u [.a.zmm) ~- ~ L __ =-a r2___T=-~11 ' " TURN COLIAR J ~ - t X l/7 RCOUCER UNNL IILNf AGAfNSI $PRINKL ER WAENLN BOSS ~ \ 7 I ~ 1 Y C - CACC OF nFNNO /0111 AOJUSIMENIIII ~S ~ C~ F2ML ~OIMENSION -~- I/8- (3.7m.~J !U A' 1 17/71. ON. OI~FL01 j77.1mmJ (If ItEFFR !O FI h FT CSLUICNFON LIOIA /ABLE FOR APPROVALS AN0 OfNEN90NS. Model F1FR 56/F1 or F2 Sprinkler Identification Number Sprinkler Approval (SIN) Height Organization - Uoriaht ~endent ent Deflectors Marked to Indicate Position 2.25" (57mm) 1, 2, 3, 4~ RA1425'~' Upright or Pendent Position 57mm 3.4 2. RA1414''"T RA 1475 Conventional HOLE IN Cf1L1NC 1 5/16" DIA. (58.7mmJ CUP r - _~ I I ' r ~ / \ / 7" x 1/2~ REDUCER FACE OF F/TTlNC TO FACE OF CFIL INC, O1MfNSlONr1f (i~ AL7JUSTMENT ('1 A OISFWI (If REFER TO FP ESCUTCHEON L74TA TABLE FOR APPROVALS ANO O/MfNSXNJS. Model F1FR 56/FP Model F1 FR Quick Response Vertical Sidewall Sprinkler Installation Wrench: Model D Sprinkler Wrench Installation Position: Upright or Pendent Approval Type: Light Hazard Occupancy Installation Data: in l N Nominal K Factor Sprinkler Approval Sprinkler om a Orifice Thread Size US Metric Hei ht g Or anizations g Identification Numbers (SIN) ''/z" (15mm) ''/z" NPT (R1/2) 5.6 8.0 2.25" (57mm) 1,2,3,4 RA1485 15mm '/z" NPT (R1/2) 5.6 8.0 2.25" (57mm) 411 1iLPC Approval is for pendent position only. Vertical Sidewall Sprinkler Type Deflector to Ceiling Distance (Min. -Max.) Upright 4" {102mm) - 12" (305mm} Pendent 4" (102mm) - 12" (305mm) Model F1 FR Quick Response Horizontal Sidewall Sprinkler Deflector: HSW Installation Wrench: Model D Sprinkler Wrench Installation Data: Horizontal Sidewall ~ Sprinkler Approval Organizations i Nominal K Factor Height and Type of Approval Sprinkler tific Id ti Nominal Orifice Thread Size en a on ~~ US Metric Light Hazard Ordinary Numbers SIN ( ~ Hazard '/z" (15mm) ''/z" NPT (R1/2) 5.6 80 2.63" (67mm) 1,2 1 RA1435 ~~ f ,, "*1 Horizontal Sidewall FACE OF F/TTY TO FACE OF CE DIMENSION 2 1/4" HOLE OIA. [57.2mm) 7" X i/2" REDUCER 1 i/4" M/N. [J 1.8mm] (3.2mmJ [701.6mm-752.4mmJ ^\, CEILING TO DEFLECTOR plA. TURN COLLAR UNTIL ~ TIGHT AGAINST SPRINKLER WRENCH BOSS. O/JFG03 1 AOJUSTMEN7( ) (1) REFER TO ESCUTCHEON DATA TABLE FOR APPROVALS ANO DIMENSIONS. 3. Model F1 FR quick Response Concealed Pendent Sprinklers Installation Wrench: Model RC1 Sprinkler Wrench Technical Data: -_ - i l K" Factor T Thread ~ l ~' Temp r Rating - Bulb I~ Sprinkler Nom na Orifice - - US ,Metric Mode Size I Sprinkler pent ' Cover ~ Temp Colar Approvals I Identification ~', Number(SIN) Yz" (15mm) 5.6 80 '/z" NPT F1FR ., - - 135°F/57°C - 135°F/57°Ct 100°F138°C Orange _ _ . -- - - ---,- 1, 2 RA1414 - --_ _.. _ -___ ''/z" { 15mm) ---__-_ ----- 5.6 80 _ .._ - ''/z" NPT I F 1 FR --- + __ - 155°F168°C --_ -...__T T 135°F/57°C ~ 100°F/38°C ' Red -~- 1, 2, 4`'' RA 1414 -- '/z" (15mm) 5.6 I 80 '/z" NPT ~ FiFR 175°F/79°C 165°F/74°C 100°FJ38°C ! Yellow 1, 2 RA1414 '/z" (15mm) 5.6 80 '/z" NPT ' F1FR 200°F/93°C 165°F/74°C 100°F/38°C Green 1, 2 RA1414 '" For vdS only = 155°F/68°C Norbulb and 112" 112,7mm] adjustment. i" r 1/7" REDUCING TEE OR ELBO1WAf}~~ _ _ _ _ ~ ~ ~~ 7 5/8" DIA. 2 5/16" D1A - I HOLE /N Cfll WG CUP ~ ~ / 2^ MAX, ,~ FACE OF FITTING ~ TO FACf OF CfILlNC i T~;~„~~i'/~ DIMENSION CEILING S I - 7/2" MAX. 15/76" COVER ADJUSTMENT I covfR PLATE - -~ ASSEMBLr ,3 5/76" DrA. SPRINKLER 1 /2" ADJUSTMENT °~FC°i Figure 1 f" . 1/7" REDUCING TEE OR ELBOW ~-~ r--J 7 5/B,. DIA. 7 5/16" D1A - ROLE /N CEILING I CUP ' ~ -- 1 I/Z" MAX. ~.~ ~~// ::: %-1 I T FACE OF FITTING TD FACf OF CE/LfNG -;~ -;; L 1.. -"~" I , , ;'~ DIMENSION CEILING T - 1 " 'J •, 5/16" MAX. J I 3/4 COVER A0./USTMENT I COVER PLATE - -J I ( ASSEMBLY 3 5/16" D/A. ~ SPRINKLER -J 5/16" ADJUSTMENT o.MOm Figure 2 Installation Aid A protective cap is included for use during installation. Im op rtant: The F1 FR 56 Sprinkler with Model CCP cover plate is not an FM Approved combination. Installation Quick response sprinklers are intended for installation as specified in NFPA 13, Quick response sprinklers and standard response sprinklers should not be intermixed. The Model F1 FR 56 Recessed Quick Response Sprin- klers are to be installed as shown. The Model F1 or F2 Es- cutcheons illustrated are the only recessed escutcheons to be used with the Modei F1FR 56 Sprinklers. The use of any other recessed escutcheon will void all approvals and negate all warranties. When installing Model F1FR 56 Sprinklers, use the Model D Sprinkler Wrench. Use the Model GFR2 Wrench for installing F1 FR 56 Recessed Pendent Sprinklers. Any other type of wrench may damage these sprinklers. NOTE: A leak tight ''/z" NPT (R1/2) sprinkler joint can be obtained with a torque of 8-18 ft-Ibs (10,8 - 24,4 N-m). Do not tighten sprinklers over maximum recommended torque. It may cause leakage or impairment of the sprin- klers. The Model F1 FR 561 CCP Concealed Sprinkler uses the Yz" orifice, %z" NPT (R1/2), 135°F (57°C), 155°F (68°C), 175°F (79°C) or 200°F (93°C) Model F1 FR 56 Pendent Sprinkler with a threaded Model CCP cup which is fac- tory attached to the sprinkler. The assembly is complet- ed by the installation of the attractive, low profile, 135°F (57°C) or 165°F (74°C) rated Model CCP push on cover plate assembly. The cover plate and sprinkler cup as- semblies are joined using a cover plate skirt with flexible tabs for threaded engagement. A choice of two cover plate assemblies provide either %z" (13mm) or 5/, 6" (8mm) of cover adjustment. Do not install these sprinklers in ceiling which have positive pressure in the space above. After a 2516" (67mm) diameter hole is cut in the ceil- ing, the sprinkler is easily installed with the Model RC1 Wrench. A Teflon` based thread sealant should be applied to the sprinkler threads only. The Model RC1 Wrench is then used to engage the sprinkler wrenching surfaces and to install the sprinkler in the fitting. When inserting or removing the wrench from the sprinkler/cup assembly, care should be taken to prevent damage to the sprinkler. DO NOT WRENCH ON ANY OTHER PART QF THE SPRINKLER. The cover plate is then pushed onto the cup. Final adjustment is made by hand turning the cover plate until the skirt flange makes full contact with the ceiling. Cover plate removal requires turning in the counter clockwise direction. 4. After installation, inspect all sprinklers to ensure that there is a gap between the cover plate and ceiling and that the four cup slots are open and free from any air flow impediment to the space above. Concealed cover plate/cup assemblies are listed only for use with specific sprinklers. The use of any other con- cealed cover plate/cup assembly with the Model F1FR 56 Pendent Sprinkler or the use of the Model CCP Con- cealed cover plate assembly on any sprinkler with which it is not specifically listed my prevent good fire protection and will void all guarantees, warranties, listings and ap- provals. Glass bulb sprinklers have orange bulb protectors to minimize bulb damage during shipping, handling and installation. REMOVE THIS PROTECTION AT THE TIME THE SPRINf(LER SYSTEM IS PLACED 1N SERVICE FOR FIRE PROTECTION. Removal of the protectors before this time may leave the bulb vulnerable to damage. RASCO wrenches are designed to install sprinklers when covers are in place. REMOVE PROTECTORS BY UNDOING THE CLASP BY HAND. DO NOT USE TOOLS TO REMOVE THE PROTECTORS. Temperatur ~ Classification ~ e Ratings Sprinkler Tem erature _ Max. Ambient T Bulb Color ~-- -- _ -- __.°C-- of-- . emp. Ordinary 57 135 100°F{38°C) Orange Ordinary Intermediate Intermediate Hi h "' 68 79 93 141 155 175 200 286 2 100°F{38°C) 150°F (66°C) 150°F (66°C) 25°F 107°C~ Red Yellow Green Blue "' Not available for recessed sprinklers. Escutcheon Data t') F SwDcheon ~.A,. Face of Fitting TA . Approvals Adjustment Nbdel i Dimension Ceiling or Wall -- - - Dimension-_- r 3 4 Max Recess F1 1 1'h"(381mm) ', '/,e _'sh: , Min Recess - - __- '/a°(191mm)_.i (Smm-24mm) Max Recess F2 i 3.4 2 1 %i' (38.1 mm) '/'~;' - ''h,:" , , Min Recess i __ 1_"_(25mm) _J_ _~5mm -_ 17mm]__ ~FP PushcN Max Recessed 4 1 'hF' (t tmm) 1'/z° (38.1mm) ' Min Recessed _ , Threadoft ~ _ _ ' 'shF. (24nxn)_ (25.~rrrnl Wit "'SIN: RA1435 - cULus and FM permits use with F 1 or F2 esc utcheons for light hazard only. Maintenance The Models F1FR 56 and F1FR 56 Recessed Sprinklers should be inspected quarterly and the sprinkler system maintained in accordance with NFPA 25. Do not clean sprinklers with soap and water, ammonia or any other cleaning fluids. Remove dust by using a soft brush or gentle vacuuming. Remove any sprinkler which has been painted (other than factory applied) or damaged in any way. A stock of spare sprinklers should be main- tained to allow quick replacement of damaged or oper- ated sprinklers. Prior to installation, sprinklers should be maintained in the original cartons and packaging to mini- mize the potential for damage to sprinklers that would cause improper operation or non-operation. Sprinkler Types Standard Upright Standard Pendent Conventional Recessed Pendent Vertical Sidewall Horizontal Sidewall Recessed Horizontal sidewall Concealed pendent Finishes (') Bronze Brass Chrome Plated Chrome Chrome White Polyester ;Plated White (~natorl tausi '' White PainTari Bright Brass "' I Bright Brass Bright Brass Black Plated ~ Black Plated Satin Black Paint `z' Black Paint Off White Off White'=' ,Off White Black Paint "'' Other finishes and colors are available on special order. Consult the factory for details. i2` cULus Listed only "' 200°F (93°C) maximum. 'a' cULus listed "corrosion resistance" applies to SIN Numbers RA1425 (Upright) and RA1414 (Pendent) in standard black or white. '~" FM Approvals finish as "Polyester coated" applies to SIN Number RA1414 (Pendent) in standard black or white. Ordering Information Specify: 1. Sprinkler Model 2. Sprinkler Type 3. Orifice Size 4. Deflector Type 5. Temperature Rating 6. Sprinkler Finish 7. Escutcheon Type 8. Escutcheon Finish (where applicable) 9. Cover plate Model t1?. Cover plate Thread size 11. Cover plate Temperature 12. Cover plate Adjustment 13. Cover plate Finish Note: When Model F1FR 56 Recessed sprinklers are ordered, the sprinklers and escutcheons are packaged separately, 5. Rel fable... For Com lete Protect I O r1 p Reliable offers a wide selection of sprinkler components. Following are some of the many precision-made Reliable products that guard life and property from fire around the clock. • Automatic sprinklers • Flush automatic sprinklers • Recessed automatic sprinklers • Concealed automatic sprinklers • Adjustable automatic sprinklers • Dry automatic sprinklers • Intermediate level sprinklers • Open sprinklers • Spray nozzles • Alarm valves • Retarding chambers • Dry pipe valves • Accelerators for dry pipe valves • Mechanical sprinkler alarms • Electrical sprinkler alarm switches • Water flow detectors • Deluge valves • Detector check valves • Check valves • Electrical system • Sprinkler emergency cabinets • Sprinkler wrenches • Sprinkler escutcheons and guards • Inspectors test connections • Sight drains • Ball drips and drum drips • Control valve seals • Air maintenance devices • Air compressors • Pressure gaugesldentification signs • Fire department connection The equipment presented in this bulletin is to be installed in accordance with the latest published Standards of the National Fire Protection Association, Factory Mutual Research Corporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable. Productsmanufactured and distributed by Reliable have been protecting life and property for over 90 years, and are installed and serviced by the most highly qualified and reputable sprinkler contractors located throughout the United States. Canada and foreign countries. Manufactured by _ The Reliable Automatic Sprinkler Co., Inc (800) 431-1588 Sales Offices {800) 848-6051 Sales Fax (914) 829-2042 Corporate Offices www.reliablesprinkler.com Internet Address Recycled Paper Revision fines ~nd~cate updated or new data EG Printed in U S A 02110 PM 9999970300 Sprinkler Drop FLEXIBLE SPRINKLER DROP c ~l vs ~~ • EasyIIex Flexible Sprinkler Drop provides fast and simple APPROVED installation. • Improved NEW TBS Brackets assures stability in the most challenging environment. FEATTJRES Hoses • Lengths: 24", 36", 48", 60", and 72" • Sizes: 1/2" or 3/4" Straight or 90° Outlet Nipples • Type: Braided (UL I FM) Upbraided (UL Brackets • TBS System (UL / FM): T-Bar Grid Commercial Suspend Ceiling • MSB System (FM): Metal Stud/Sheetrock Suspend Ceiling TECHNICAL DATA TE • Temperature: 225°F • Pressure: 175 psi • Connection: Inlet: 1" NPT Outlet: 1/2" or 3/4" NPT • Maximum Bend Radius: 4" (UL), 8" (FM) *Do not bend within 2.52 inches from connection nuts. • Maximum Number of Bend: Refer to Fiction Loss Data • K-Factor: Z/2" Outlet: 5.6 gpm 3/4" Outlet: 8.0 gpm N PRODUCT SUBMITTAL Job Name: Job Location: Submitted By; Date: Approval: Date: s5o4z Parkway Loop Un it p T:7u~ 258 z6oo / 888 577 8999 Tustin, CA 9z~8o-65zz F;7i4 z58 z6oz www.easyftexusa.com E-mail:infoC~easyftexusa.com EASYFLE~J~C prinkter Drop FRICTION LOSS DATA Length (Inch) Outlet Connection Maximum Number of 90° Bends (L]L) Equivalent Length of 1 in. Schedule 40 Pipe, ft (FM / UL) ° 1/2" I 6.8 / 18 24 314" 1 4.7118 " 1/Z" 2 11.5 / 31 36 314" 2 10.6 / 34 „ 1/2" 3 16.7 / 48 4$ 3/4" 3 12.7 / 61 1/2" ¢ 20.6 / 60 60" 3/4„ 4 17.0 / 65 „ 1/2" 4 24.0 / 71 72 3/4" 4 19.8 / 72 * Differences of Friction Loss Data axe due to the different test methods and conditions between UL ana r~rn approval. FM Approval: 8" Minimum Bend Radius, where C =100 / UL: 4" Minimum Bend Radius, where C = 120 APPLIANCE STANDARDS • American Society for Testing and Methods (ASTM) - ASTM C635 Standards Specification for the Manufacture, Performance, and Testing of Metal Suspension Systems for Acoustical Tile and Lay-in Panel Ceilings - ASTM C636 Standards Practice for Installation of Metal Ceiling Suspension Systems for Acoustical Tile and Lay-in Panels • FM Approval (F11~ - FM Class Number 1637 Approved Standard for Flexible Sprinkler Hose with Threaded End Fittings National Fire Protection Association (NFPA) - NFPA 13 Standard for the Installation of Sprinkler Systems - NFPA 13D Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes - NFPA 13R Standard for the Installation of Sprinkler Systems in Residential Occupancies Up to and Including Foux Stories in Height • Underwritings Laboratories, Inc. (UL) - UL 2443 Standards for Flexible Sprinkler Hose with Fittings for Fire Protection Service MATERIAL SPECIFICATION 1. Corrugated Flexible Hose: SS 304 2. Braid: SS 304 3. Nut and Nipple: Zinc Plated Carbon Steel 4. End Brackets: Zinc Plated Carbon Steel 5. Stock Bar: Zinc Plated Carbon Steel 6. Center Bracket: Zinc Plated Carbon Steel 7. Gasket: EPDM i5o4z Parkway Loop Unit D T:7i4 258 2600 / 888 577 $949 Tustin, CA 9z78o-b5zz F:7~ z58 z6oz www.easyftexusa.cam E-mail:infoQeasySexusa.com