08026 A1.00 Architectural Site Plan OPTION 3 (2)Transmittal Report:
Created by AutoCAD eTransmit Thursday, September 11, 2008, 5:06 PM.
Drawing:
This is a transmittal based on 08026 A1.00 Architectural Site Plan OPTION 3.dwg.
Files:
Root Drawings: 08026 A1.00 Architectural Site Plan OPTION 3.dwg
AutoCAD Drawing (External) References:
7592TOPO.dwg
08026 Title-Block 24x36.dwg
08026 TP01.dwg
AutoCAD Font Map References:
acad.fmp
AutoCAD Plot Style Table File References:
PlotCfgs\Aec Standard.stb
AutoCAD Plotter Configuration File References:
PlotCfgs\DWF6 ePlot.pc3
JPEG Image References:
Textures\Finishes.Gypsum Board.Painted.White.jpg
Textures\Finishes.Metal Framing Systems.Furring.jpg
Textures\Finishes.Metal Framing Systems.Stud.jpg
Textures\Masonry.Unit Masonry.Brick.Modular.Running.jpg
Textures\Masonry.Unit Masonry.Brick.Modular.Running.Red.jpg
Textures\Masonry.Unit Masonry.CMU.Stretcher.Running.jpg
Textures\Metals.Metal Fabrications.Metal Stairs.Galvanized.jpg
AutoCAD Color-dependent Plot Style Table File References:
PlotCfgs\_TGBA.ctb
The following files were excluded from the transmittal:
Template\Aec Model (Imperial Stb).dwt
Fonts\simplex.shx
Fonts\romans.shx
Aec Sheet Set (Imperial Stb).dst
MAHI-MAHI.apj
MAHI-MAHI.dst
MAHI-MAHI.rpq
Default_Project_Image.bmp
Sample Project Bulletin Board.htm
Fonts\ARIALN.TTF
Fonts\ARIAL.TTF
Fonts\ARIALBD.TTF
Fonts\ltypeshp.shx
Fonts\txt.shx
Fonts\romand.shx
Fonts\complex.shx
The following files could not be located:
b-romans.(shx,ttf)
Textures\Doors & Windows.Door Hardware.Chrome.Satin.jpg
Textures\Doors & Windows.Metal Doors & Frames.Aluminum Frame.Anodized.Dark Bronze.Satin.jpg
Textures\Doors & Windows.Wood Doors.Ash.jpg
Textures\Woods & Plastics.Finish Carpentry.Wood.White Ash.jpg
PlotCfgs\_TGB Standard.ctb
Conversion:
All drawing files were converted to AutoCAD 2000/LT2000 format.
Notes for distribution:
.DWG external reference files:
External reference (xref) paths may be present. Make sure these paths work or that the root drawing is using the correct references.
eTransmit does not include files required by xrefs unless they are also required by the root drawing. In particular, plot style tables and overlay xrefs that are not used by the root
drawing are omitted
.PC3 printer configuration files:
Please copy these files to the AutoCAD Printer Configuration Search Path directory.
.CTB/.STB plot style tables:
Please copy these files to the AutoCAD Plot Style Table Search Path directory.
Material texture files:
Please copy these files to the AutoCAD Texture Maps Search Path directory.
The AutoCAD variable FONTALT was set to:
C:\Documents and Settings\jeremiahm\Application Data\Autodesk\ACD-A 2009\enu\Support\simplex.shx
Please make sure that the FONTALT variable is set to this file or an equivalent before opening any drawings. All text styles with missing fonts are automatically set to this font.