ACU NREC Env-Ltg2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011
Project Info Project Address AMERICA'S CREDIT UNION Date 4/5/2011
41s Ye lm Avenue For Building Department Use
Yelm, WA
Appllcant Name: ZENCZAK & PARTNERS
Applicant Address: asas S UNION AVENUE, SUITE 200
Applicant Phone: zss-ass-osao
Project Description ^ New Building ^ Addition ^ Alteration ^ Change of Use
^ Prescriptive ^ Component Performance ^ Seattle EnvStd
compliance Option (See Decision Flowchart (over) for qualifications) ^ SystemsAnalysis
Occupancy Group ~ Nonresidential ^ Multifamily Residential
Climate Zone ~ Climate Zone 1 ^ Climate Zone 2 (See WSEC 302.3 for county list)
Fenestration Area
Calculation Total Fenestration
(rough opening) Gross Exterior
These fenestration and wall values are (vertical & overhd) divided by Wall Area times 100 equals °k Fenestration
calculated perinputs provided in the
ENV-UA form. In the electronic form 5 7 6 . 0 - 4 8 71.0 )(~ 00 = 11.8 0
these cells auto-fill and cannot be edited.
Allowable if project meets all requirements as defined in section 1310.2. Only allowed as
Semi-Heated Path O no prescriptive path and must be calculated separately from other conditioned spaces. Limited to
reduced wall insulation levels. Requires other fuel heating and qualifying thermostat.
Envelope Requirements (enter values as applicable)
Minimum Insulation R-values I
Roofs -Insulation Above Deck
Roofs -Metal Building
Roofs -Single Rafter
Roofs -Attic and All Others
Walls -Mass
Walls -Metal Building
Walls -Steel Framed
Walls -Wood Framed and Other
Floors -Mass
Floors -Steel Joist
Floors -Wood Framed and Other
I Maximum F-factors I
(Slabs-on-Grade -Unheated
Slabs-on-Grade -Heated
(Envelope Requirements (continued)
Maximum U-factors I
Vertical Fenestration
Non-Metal Frame
Metal Frame
Entrance Door
Skylights -Without Curb
Skylights -With Curb
Opaque Doors -Swinging
Opaque Doors -Non-Swinging
Maximum SHGC (or SC)
Vertical Fenestration
Non-North
North
Skylights
Notes:
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011
Minimum Requirements
for Prescriptive Option Use table to determine if project qualifies for the optional
Prescriptive Option. All components must meet the stated
Climate Zone Climate Zone 1 Climate Zone 2
Occupancy Group Nonresidential Residential, Other
than Single-Family Nonresidential Residential, Other
Single-Family
Opaque Elements Insulation Min. R-Value
Roofs
Insulation Entirely above Deck R-30 c.i. R-38 c.i. R-38 c.i. R-30 c.i.
Metal Building R-25 + R-11 Ls R-25 + R-11 Ls R-25 + R-11 Ls R-25 + R-11 L~
Single-Rafter R-38 R-38 R-38 R-38
Attic and Other R-38 adv or R-49 R-38 adv or R-49 R-38 adv or R-49 R-38 adv or R-4
Walls, Above-grade
Mass R-5.7 c.i. i R-11.4 c.i. i R-7.6 c.i. R-13.3 c.i.
Metal Building R-13 + R-7.5 c.i. R-19 + R-8.5 c.i. R-13 + R-7.5 c.i. R-19 + R-16 c.i
Steel Framed R-13 + R-7.Sc.i. R-19 + R-8.5 c.i. R-13 + R-7.5 c.i. R-19 + R-14 c.i
Wood Framed and Other R-21 R-13 + R- 6 c.i. R-13 + R-7.5 c.i., or
R-21 + R-2.5 c.i. R-21 + R-5 c.i.
Below Grade Wall Same as above grade Same as above grade
Floors
Mass R-30 c.i. R-30 c.i. R-30 c.i. R-30 c.i.
Steel Joist R-38 + R-4 c.i. R-38 + R-4 c.i. R-38 + R-4 c.i. R-38.0 + R-4 c.i
Wood Framed and Other R-30 R-30 R-30 R-30
Slab-On-Grade Floors
Unheated R-10 for 24 in. (with
thermal break) R-10 for 24 in. (with
thermal break). R-10 for 24 in. (with
thermal break) R-10 for 24 in. (w
thermal break)
Heated R-10 c.i.(with thermal
break) R-10 c.i. (with thermal
break) R-10 c.i. (with thermal
break) R-10 c.i. (with ther
break)
Opaque Doors Maximum U-Factor
Swinging U-0.600 U-0.400 U-0.600 U-0.400
Non-Swinging U-0.600 U-0.400 U-0.600 U-0.400
Fenestration 0-40% o Wall Assembly Maximum U-factor (NFRC Rated)
Vertical Fenestration
Nonmetal framing U-0.32 U-0.32 U-0.32 U-0.32
Metal framing U-0.40 U-0.40 U-0.4p0 U-0.40
Entrance doors U-0.60 U-0.60 U-0.60 U-0.60
Skylights
Without curb (i.e. sloped U-0.50 U-0.50 U-0.50 U-0.50
With curb (i.e. individual unit U-0.60 U-0.60 U-0.60 U-0.60
Fenestration 0-40% o Wall Assembly Maximum SHGC Factor
Vertical Fenestration SHGC-0.40 all, OR
SHGC-0.45 all PLUS
permanent PF > 0.50 on
west, south, east No Requirement SHGC-0.40 a11, OR
SHGC-0.45 all PLUS
permanent PF > 0.50 on
west, south, east No Requirement
Sk li hts SHGC-0.35 SHGC-0.35 SHGC-0.35 SHGC-0.35
The following definitions apply: c.i. =continuous insulation, Ls =liner system (see definitions)
Footnote 1: Zone 1, nonresidential walls maybe ASTM C90 concrete block walls, ungrouted or partially grouted at 32 inches or less on center
vertically and 48 inches or less on center horizontally, with ungrouted cores filled with material having a maximum thermal conductivity of
0.44 Btu-in/h~ft2~ F.
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011
ProjectAddress AMERICA'S CREDIT UNION Date 04/05/2011
Occupancy Group ~ Nonresidential ~ Multifamily residential Clear For Building Department Use
Climate Zone ~ Zone 1 ~ Zone 2
Fenestration Area as °k gross exterior wall area 11.8 o Max. Target: 40.0 0
Notes: 1: If fenestration area exceeds maximum allowed, then calculate adjusted areas on Target Area
Adjustment sheet on the backside of the ENV-SHGC form.
2: U-factors shall come from chapter 10 or calculated per 1332.
See the ENV-CHK worksheet for example of how to complete the rows on this form.
Building Component Proposed UA Target UA
Provide assembly ID & page/plan # for each bldg. element U-factor x Area (A) = UA (U x A U-factor x Area (A) = UA (U x A)
Y R=25 ID: 0.040 4380 175.2 0.034 4380 148.9
~ R= ID: Above Deck Insulation U-0.034
0
R= ID:
w ~ R= ID: 0.031
°° R= ID: Metal Building U-0.031
~ R= ID:
R= ID: 0.027
R= ID: Single raft, attic, other U-0.027
O R= ID:
E R= ID: 0.064
~ R= ID: Steel frame/metal bldg U-0.064
R= ID:
> ~ R= ID:
~
Q t R=21 ID: 0.048 1253 59.7 0.057 4274 243.6
y ~ R=21 ID: 0.048 884 42.1 Wood Frame, other U-0.057
°° R=21 ID: 0.048 1253 59.7
° ~ R=21 ID: 0.048 884 42.1
'v
m R= ID: 0.150
~ N R= ID: Mass Wall U-0.150
~ R= ID:
~ R= ID:
Proposed assembly U-factor from Tables 10-5 thru 10-5B
w R= ID: 0.150
m
o ~
R= ID:
Assumed to be Mass Wall U-0.150
m ~ R= ID:
m
~
Proposed assembly U-factor from Tables 10-5 thru 10-5B. Do NOT us
e Table 10-1.
a~ N U= 0.6 ID: 0.600 21 12.6 0.60 21 12.6
a °
° o U= ID: All Doors U-0.60
O ~ U= ID:
,~ R= ID: 0.029
$ R= ID: Floors U-0.029
R= ID:
F-factor x Perimeter = UA(U x A) F-factor x Perimeter = UA (U x A)
°~i R=1.5 ID: 0.667 304 202.7 0.540 304 164.2
R= ID: Slab-On-Grade U-0.540
~ ~ R= ID:
° ~ R= ID: 0.360
~ R= ID: Heated Slab-On-Grade U-0.360
x
Proposed assembly F-factors can use the unheated values in Table 10-2
'gone ~ cnnu watts meeunqq iaoie ~:~-~ rootnote ~ can oe entered Area UA Area UA
with U-value of 0.15 ratherThan Table 10-5b values. Plans must
clearly state footnote requirements. Page 1
Subtotal 8979 594 8979 569
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily
Project Address AMERICA'S CREDIT UNION Date 04/05/2011
Fenestration Area as °k gross exterior wall area 11.8 o Max. Target: 40.0 o For Building Department Use
Notes: 1: If fenestration area exceeds maximum allowed, then calculate adjusted areas on Target Area
Adjustment sheet on the backside of the ENV-SHGC form.
2: Provide NFRC or Table 10-6 U-factor (See Section 1312.1) for fenestration assemby (combined
See the ENV-CHK worksheet for example of how to complete the rows on this form.
Building Component Proposed UA Target UA
Provide assembly ID & page/plan # for each bldg. element U-factor x Area (A) = UA (U x A U-factor x Area (A) = UA (U x A)
U=0.37 ID: 0
37 235 87.0 0.40 506 202.4
~ .
~ U= 0.37 ID: 0.37 101 37.4 Metal Frame
~ U= 0.37 ID: 0.37 45 16.7 U-0.40
~ ~ U= 0.37 ID: 0.37 125 46.3
o
~ ~
~ U= ID: 0.37
~ U= ID: 0.32
U= ID: Non-Metal Frame
o U= ID: U-0.32
U
a~ Z U= ID:
~ ~ U=0.45 ID: 0.45 70 31.5 0.60 70 42.0
U= ID: Metal Entance Door
°~i U= ID: U-0.60
~ U= ID:
~ U= ID: 0.50
v U= ID: Without Curb
z U= ID: U-0.50
w
U= ID:
Y a U= ID: 0.60
~ v U= ID: Including Curb
U= ID: U-0.60
~
U= ID:
Area ~ UA Area ~ UA
Page 2 Subtotal
Page 1 Subtotal
To comply:
Total
576 219
8979 594
9555 813
576 244
8979 569
9555 814
1) Proposed Total UA shall not exceed Target Total UA.
2) Proposed Total Area shall equal Target Total Area.
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011
Project Address AMERICA'S CREDIT UNION Date 04/05/2011
FeneStTatlOn Area as °~ gross exterior wall area 11.8% prop 40% Max.Target For Building Department Use
Prescriptive PF Credit O Yes O No
Vertical North Facing Credit (1323.3 Exp. 2) O Yes O No
Notes: To comply the Proposed total SHGC x A for all fenestration (vertical & skylights) shall not exceed Target
total SHGC x A. If the north facing credit is used then the north and non-north must comply separately with
skylights being included with the non-north vertical fenestration.
Skylights Proposed SHGC Target SHGC
List ID & page #, NFRC or glass only SHGC' x Area (A) = SHGC x SHGC x Area (A) = SHGC x A
ID: 0.35
ID: Criteria SHGC
I D: All 0.35
ID:
ID:
Note: Manufacturer's SC may be used in lieu of SHGC. Totals Totals
Nonresidential compliance is based upon combined skylight and vertical
fenestration performance. Residential compliance is based upon skylight
only.
All Non-North Vertical Fenestration++ Proposed SHGC Target SHGC
PF Adjusted
List ID & page #, NFRC or glass only SHGC+ PF
x Area (A) = SHGC x
" SHGC x Area (A) = SHGC x A
SHGC
Mult
ID: 0.36 1.00 0.36 101 36 0.40 341 136.4
ID: 0.36 1.00 0.36 45 16 Criteria SHGC
ID: 0.36 1.00 0.36 125 45 All 0.40
ID: 0.36 i.oo 0.36 70 25 Prescriptive PF 0.45
ID:
ID:
ID:
ID:
ID:
ID:
++Note: If projection factors or north vertical glazing credit are used Totals 341.0 122 .8 Totals 341.0 136 .4
then vertical fenestration must be entered according to orientation. If
neither are used then ventical fenestration can be entered in either section. Non-North Total 122 .8 136 .4
+ Note: Manufacturer's SC may be used in lieu of SHGC. Fenestration that
separates conditioned space from anon-conditioned orsemi-conditioned space
shall be listed here with a proposed SHGC equal to the target value.
Note: Multipliers only apply if prescriptive PF credit not used.
North Vertical Fenestration++ Proposed SHGC Target SHGC
PF Adjusted
List ID & page #, NFRC or glass only SHGC+ pF
x Area (A) = SHGC x
" SHGC x Area (A) = SHGC x A
SHGC
Mult
ID: 0.36 1.00 0.36 235 85 0.40 235 94.0
ID: Criteria Mixed North
ID: Orientation Separate
ID: All 0.40 0.45
ID: Prescrpt P 0.45 0.50
ID:
North Total 235.0 84.6 235.0 94. 0
For compliance: Proposed total SHGC x A shall not exceed Target total SHGC
x A. If north glazing credit is used then north facing vertical fenestration must Area SHGC x A Area SHGC x A
comply separately from non-north vertical fenestration and skylights. Grand Grand
576.0 207.4 576.0 230.4
Total Total
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011
Project Address AMERICA'S CREDIT UNION Date 04/05/2011
If the total fenestration area as a % of gross exterior wall area (calculated on ENV-SUM) exceeds the maximum allowed in Table 13-1,
then this calculation must be submitted Use the resulting areas in the Target UA and SHGC calculations above.
SKY= Skylight. Refered to as overhead glazing in WSEC 1333 & 1334 and equations 13-1 & 13-2.
VF =vertical fenestration. Refered to as vertical glazing in WSEC 1333 & 1334 and equations 13-1 & 13-2.
NW =net wall (excludes fenestration, BG, and doors.) DBG =Doors and below grade wall.
Total Fenestration =SKY + VF. Gross Exterior Wall Area= VF + NW +DBG
Proposed Areas
Above Grade Walls Doors & BG Walls
Fenestration -=
Opaque -~
SKY= VF= 576.0 0
NW= 4274.0 DBG= 21.0
Gross Exterior Max Fenestration % Maximum Target
Wall Area (Table 13-1) Fenestration Area
4871.0 X 40.0 - ~QQ = 1948.4
Total Fenestration Maximum Target Excess Fenestration 0 Excess Fenestration
576.0 - 1948.4 = -1372.4 - ~ lesser
-1372.4
Total Fenestration Excess Fenestration Target Fenestration Total Fenestration Target VF Multiplier Apply to all Proposed
576.0 - = 576.0 - 576.0 = 1.00 Fenestration Areas to get
Target Fenestration Area
Net AG Wall Area Excess Fenestration Target Net Wall Area Net Wall Target Net Wall Mult. Apply to all Proposed
4274.0 + = 4274.0 - 4274.0 = 1.00 Opaque AG Wall Areas to
get Target Area
Vertical Fenestration Proposed Area Target VF Mult. Target Area
metal frame 506.0 X 1.00 = 506.0
non-metal frame X =
metal entrance 7 0. 0 X 1.00 = 7 0. 0
Skylight Proposed Area Target VF Mult. Target Area
without curb X = Target areas in shaded
_ boxes shall be used as
with curb )( - target areas on ENV-UA.
AG Wall Proposed Area Target Net Wall Mult. Target Area
Steel Frame/metal X =
Wood/Other frame 4274.0 X 1.00 = 4274.0
Mass X =
Sum of Proposed 4850.0 Sum of Target 4850.0 Sum of Proposed must
equal Sum of Target.
SHGC Calculation Proposed Area Target VF Mult. Target Area
Skylights (all) X = SHGC target areas in
Non-North Vertical Fenestration 341.0 1.00 = 341.0 shaded boxes shall be
X entered as target areas
North Vertical Fenestration 235.0 X 1.00 = 235.0 on ENV-SHGC
2009 Washinaton State Enerav Code Compliance Forms for Nonresidential and Mu
Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011
Project Address AMERICA'S CREDIT UNION (Date 4/5/2011
The following information is necessary to check a building permit application for compliance with the building envelope requirements in the
Washington State Nonresidential Energy Code.
Applicability Code Location Building Department
(yes,no,na) Section Component Information Required on Plans Notes
GENERAL REQUIREMENTS (Sections 1301-1314)
1301 Scope Unconditioned spaces identified on plans if allowed
N•A• 1310.2 Semi-heated spaces Semi-heated spaces identified on plans if allowed
N.A. 1310.3 Cold Storage / refrigerat All refrigerated spaces identified on plans. ENV-RFG completed.
1311 Insulation
Yes 1311.1 General installation Indicate installation nethod, densities and clearances to achieve A4.1
intended R-value of all insulation materials A4.2
Yes 1311.2 Roof /ceiling insul. Indicate R-value on roof sections for attics and other roofs; A4.1
IndlCate ClearanC2S for attlC InSUlatlOn; A4.2
Indicate baffles if eave vents installed;
Indicate face stapling of faced Batts
Yes 1311.3 Wall insulation Indicate R-value and framing material on wall sections; A4.1
Indicate face stapling of faced Batts; HY . L
Indicate above grade exterior insulation is protected;
Indicate mass of masonry walls if mass wall claimed
Indicate loose-fill core insulation for masonry walls as necessary
Indicate frequency of grouted cores and bond beams as necessary
N.A. 1311.4 Floor insulation Indicate R-value on floor sections;
Indicate substantial contact with surface;
Indicate supports not more than 24" o.c.;
Indicate that insulation does not block airflow through foundation vents.
N.A. 1311.5 Slab-on-grade floor Indicate R-value on wall section or foundation detail;
Indicate slab insulation extends down vertically 24" from top;
Indicate above grade exterior insulation is protected
N.A. 1311.6 Radiant floor Indicate R-value on wall section or foundation detail;
Indicate slab insulation extends down vertically 36" from the top;
Indicate above grade exterior insulation is protected;
Indicate insulation also under entire slab where req'd. by Official
Yes 1312 Glazing and doors Provide calculation of vertical and overhead glazing area as percent of gross wall are ENV-UA
Yes 1312.1 U-factors Indicate glazing and door U-factors on glazing and door '
schedule (provide area-weighted calculations as necessary);
Indicate if values are NFRC or default, if default then specify
frame type, glazing layers, gapwidth, low-e coatings, gas filling
Yes 1312.2 SHGC & SC Indicate glazing solar heat gain coefficient or shading coefficient on glazing A5 • I
schedule (provide area-weighted calculations by orientation as necessary)
1313 Moisture control
Yes 1313.1 Vapor retarders Indicate vapor retarders applied to warm side of insulation A4.1
N.A. 1313.2 Roof/ceiling vap.ret. Indicate vapor retarder on roof section; or list exception
Indicate vap. retard. with sealed seams for non-wood structure
Yes 1313.3 Wall vapor retarder Indicate vapor retarder on wall section A4.1
m. A. 1313.4 Floor vapor retarder Indicate vapor retarder on floor section
N.A. 1313.5 Crawl space vap. ret. Indicate required grade ground cover with required overlapping.
1314 Air leakage
Yes 1314.1 Bldg. envel. sealing Indicate sealing, caulking, gasketing, and weatherstripping A7.I
Yes 1314.2 Glazing/door sealing Specify maximum air leakage rates for fenestration and door products A7. I
N.A. 1314.3 Assemb. as ducts Indicate sealing, caulking and gasketing
N.A. 1314.4 Recessed Lighting Fixtu Indicate IC rating, ASTM E283 cert., and gasketing or caulking to ceiling
N.A. 1314.5 Loading Dock Seal Indicate weatherseal at cargo and loading dock doors
N.A. 1314.6 Continuous Air Barrier Indicate air barrier sealing on all roof, wall & floor details
Indicate leakage testing method.
Provide testing results to building official. Max. leakage of 0.40 cfm/ft2 at 0.3 inch w.g.
PRESCRI PTIVE PERFORMANCE Sections 1320-1323
No ENV-SUM Form Completed and attached.
1323 Glazing Indicate number of glazing panes and location of emissivity coating or exception taken
COMPON ENT PERFORMANCE Sections 1330-1338
Yes ENV-SUM, ENV-UA, Completed and attached.
& ENV-SHGC Forms
If "no" is shown for any question, provide explanation:
2009 Washinaton State Enerav Code Compliance Forms for Nonresidential and Mu
X2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifarr Revised February 2011
FENESTRATION, SKYLIGHTS, & DOORS: Per Energy Code Section 1312.1,
• U-factors shall be "determined, certified, and labeled in accordance with RS-31 by a certified independent agency
licensed by the National Fenestration Rating Council (NFRC. " If using this approach, provide manufacturer,
model number and NFRC rating on the drawings.
• "Unlabeled glazing and doors shall be assigned the default U factor in Table 10-6. ". If using this approach,
provide all glazing characteristics on the drawings: list number of glazing layers, gap width, low-e coating, gas
fill, frame material thermal break details per footnote 2 to Table 10-6B.
OPAQUEASSEMBLIES: Per Energy Code Section 1332,
• "The U factors for typical construction assemblies are included in Chapter 10. These values shall be used for all
calculations." For example: see Table 10-SA for metal stud walls and metal building walls/roofs, see Table 10-7A
to E for steel truss ceilings, etc.
FURTHER INFORMATION.• Refer to the Northwest Energy Efficiency Council website at: www.neec.net
Below are examples of how the Component Information on ENV-UA-1 are to be completed
Building Component Proposed UA Typical Example
List ID & a e # code table # or calculation a e # U-factor x Area A
Roofs
Othe R= 38 ID: Rl/A1.5, T.10-7 default 0.031 532 R-38 blown-in attic insulation er default
dark R=40 Ip:R2/A1.5, T.10-7G default 0.025 9885 R-40 uniform thicknessri id insulation erdefault
Walls
~ R=13+7.5 ID:wl/A1.6, T.10-5A(1) default 0.064 7587 R-13 cavity+R-7.Srigid ins. over metal studs per default
s R=5 ID: W2/A1.6, T.10-5B (2) default 0.157 923 R-5 rigid ins. at edge of intermediate concrete floors perdef
n R= ID:
O R= ID:
O R= 11 I p: W4 /Al . 6 , T .10 - 5 (1) default 0 .0 94 512 R-11 cavity ins. between wood studs on conc. wall per def.
m R= ID:
Doors
U= 0.6 I p: Dl /Al . 3 , T .10 - 6 default 0 .6 0 12 0 Non-NFRC fire-rated exit door per default
U= 1.2 I p: D2 /Al . 3 , T .10 - 6 default 1.2 0 4 0 Non-NFRC warehouse door er default
Floors and Slabs
FIOOr R= 30 Ip: Fl/A1.7, T.10-4A default 0.031 10417 R-30 continuous ins. under concrete floor slab per default
R= ID:
Slab R= 10 I D: F A T . - e au t R-10 slab ed e ins. for 2 feet without thermal break er def.
Fenes tration and Sk li hts
ID:wl A1.3, NFRC certified 0.36 12307 Curtainwallrated,certified,andlabeledperNFRC
ID: W2/A1.3, T.10-6 default 0.50 5240 Non-NFRC curtainwall, 2layer, O.OSemis, argon, TB, fixed
~ ID: W3/A1.3, T.10-6 default 0.65 282 Non-NFRC curtainwall, 2layer, O.OSemis fixed
~ ID: W3/A1.3, T.10-6 default 0.78 282 Non-NFRC curtainwall, 21a er, O.OSemis o erable
~t
m ID: S1/A1.3, NFRC certified 0.50 453 Sloped glazing rated, certified, and labeled per NFRC
~~ ID: S2/A1.3, T.10-6 default 0.78 118 Non-NFRC atrium sloped glazing, 2layer, 0.05 emis., fixed
2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010
Project Info Proj Addres415 Yelm Avenue East Date 4/19/2011
Yelm, wA For Building Department Use
Name: Zenczak & Partners
Appl. Name 4s4s S. Union Ave. , Suite 200; Tacoma, wa
Appl. Phone (zs3> 47s-0380
Project Description ®New Q Addition Q Alteration Q Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Lighting Zone
(as specified by Jurisdiction) Q Zone 1 • Zone 2 Q Zone 3 Q Zone 4
Compliance Option ~ Lighting PowerAllowance Q SystemsAnalysis
Building Grounds QEfficacy> 60 IumensM/ 0 Controlled by motion sensor
(luminaires > 100 Watts)
Q Exemption (list)
Alteration Exceptions Q No changes are being made to the lighting and space use not changed.
(check appropriate box -sec. 1132.3) 0 Lessthan 60°k of fixtures are new, installed wattage not increased, & space use not changed.
Tradable Maximum Allowed Lighting Wattage Base Site Allowance: 600
Tradable Surfaces
Description
per ft~ or per If Area ( ), perimeter
(If) or # of items
x fie (or x If)
Uncovered Parking and drives parking Lots 0.06 W/ft2 14831 890
Grounds Walkways <10 wide 0.7 W/LF 252 176
Landscaping 0.05 W/ft2 11766 588
Main Entry 20 W/LF of door wid 12 240
Entry Canopies 0.25 W/ft2 105 26
Sales Canopies 0.6 W/ft2 962 577
Total Allowed Tradable Watts 2498
I~raClable 1'ropOSeCI Llghtlrig Wattage (use mfgr listed maximum input wattage for luminaire.)
Surface
Fixture Description Number of
Fixtures Watts/
Fixture Watts
Proposed
Uncovered Parking & Drives Cooper Lighting Mtl Halide 9 250 2250
Entry Canopies Recesed Cans 6 2 $ 16 $
Landscaping wall Mounted Down Light 4 78 312
Sales Canopies Soffit Down Lights 2 175 350
Total proposed tradable watts may not exceed the sum of total allowed tradable watts Total Proposed Tradable Watts 3080
plus the base site allowance. Any base site allowance not needed to make tradable watts
comply can be applied to individual non-tradable categories.
2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential
Non-Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: ~ 8
Non-Tradable Surfaces
Description owe a ~
per ft~ or per If Area ( ), perimeter
(If) or # of items owe a s
x fie (or x If)
Bldg. Facade (by perim) 2.5 W/If 300 750
Automated Teller 270W + 90W per ad 2 3 60
Drive up Windows & Doors 400W per driveup 2 800
Non-Tradable Proposed Lighting Wattage
Surface
Fixture Description Number of
Fixtures Watts/
Fixture Watts
Proposed
Drive up Windows & Doors Wall mounted Down light 1 28 28
Drive up Windows & Doors Soffit Down lights 4 175 700
Automated Teller Soffit Down lights 1 175 175
Bldg. Facade (by perim) Wall mounted down light 9 78 702
Non-tradable proposed watts may not exceed allowed watts for any individual Total excess Non-Tradable watts: 0
surface unless the total excess watts for all non-tradable surfaces are less than ~ 8
the remaining site allowance. Site Allowance Balance:
2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010
TABLE 15-2B
LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS
Specific area description Zone 1 Zone 2 Zone 3 Zone 4
Base site allowances 500 W 600 W 750 W 1300 W
Tradable Surfaces z
Uncovered Parking Parking lots and drives 0.04 W/ftz 0.06 W/ftZ 0.10 W/ftz 0.13 W/ftz
Areas
Building Grounds
Walkways less than 10 ft wide 0.7 W/linear 0.7 Vv/ 0.8 W/ 1.0 W/
foot linear foot linear foot linear foot
Walkways 10 ft wide or heater 0.14 Vv/ft~ 0.14 W/ftZ 0.16 W/ft~ 0.2 W/ft~
Plaza areas
S ecialfeature areas
Exterior Stairways 0.75 W/ftz 1.0 W/ftz 1.0 W/ftz 1.0 W/ftz
Pedestrian tunnel O.li W/ft~ 0-15 W/ft~ 0.2 W/ft~ 03 W/ft~
Landscaping 0.04 W/ftz 0.05 W/ftZ 0.05 W/ftz 0.05 W/ftz
Building Entrances 20 W/lntear 20 W/linear 30 W/linear 30 W/linear
and Exits Main entries foot of door foot of door foot of door foot of door
width width width width
Other doors 20 W/linear 20 W/linear 20 W/linear 20 W/linear
foot of door foot of door foot of door foot of door
wiatlt width width width
Entry canopies 0.25 W/ft~ 0.25 W/ft~ 0.4 W/ft~ 0.4 W/ft~
Sales Canopies Free standing and attached 0.6 W/ftz 0.6 W/ftz 0.8 W/ftz 1.0 W/ftz
Outdoor Sales Open areas3 0.25 W/ft~ 0.25 W/ft~ 0.5 W/ft~ 0.7 W/ft~
Street frontage for vehicle No 10 W/linear 10 W/linear 30 W/linear
sales lots in addition to "open Allowance foot foot foot
area"" allowance
Non-Tradable Surfaces4
Building Facades No Allowance 0.1 W/ftz for 0.15 W/ftz for 0.2 W/ftZ for
each each each illuminated
ilhminated illuminated wall or stuface~
wall or surfaces wall or surface
Automated teller machines and night depositories 270 W per 270 W per 270 W per 270 W per
locations locations locations location
Entrances and gatehouse inspection stations at guarded 0.75 W/ftz of covered & uncovered area
facilities
Loading areas for law enforcement, fire, ambulance 0.5 W/ftZ of covered & uncovered area
and other emer6enc • service vehicles
Material handling and associated storage No Allowance No Allowance No Allowance 0.5 W/ftz
Drive-up Windows & Doors 400W per drive-tlu~ough
Parking near 24-hour retail entrances 800 W per main entry
FOOTNOTES FOR TABLE 15-2B:
1. Base site allowance may be used in tradable or nontradable surfaces.
2. Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and
outdoor sales areas maybe traded.
3. Including vehicle sales lots.
4. Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded
between stu~faces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in
the "Tradable Surfaces" section of this table.
5. May alternately use 2.5 watts per linear foot for each wall or surface length.
6. May alternately use 3.75 watts per linear foot for each wall or surface length.
7. Mav alternately use 5 watts per lntear foot for each wall or surface length.
8. An additiona190 watts is allowed per additional ATM location.