FC_0742557-10.rev_1General Field Data Technician: Paul Carson Test Date: 9/9/2011 Weather: Test Results Set No. Specimens Made Ticket Time Batched Time Unloaded Slump (in) Air Content (%) Air Temp. (°F)
Concrete Temp. (°F) 0742557-10-C1 5 558410 06:06 07:10 5.25 1.30 46 68 Location & Remarks Set No. Location General Location: SOG @A-K/1-10 0742557-10-C1 Slab on grade @A-K/1-10 Mix Data
Set No. Supplier Mix Design Strength (psi) 0742557-10-C1 Holroyd 575FA25 3000 Concrete Field Report Professional Service Industries, Inc. 10025 South Tacoma Way, #H1 Tacoma, WA 98499
Phone: (253) 589-1804 Fax: (253) 589-2136 Report No: FC:0742557-10 Issue No: 1 Project: AMERICAS CREDIT UNION YELM, WA Client: AMERICAS CREDIT UNION PO BOX 33338 FT. LEWIS, WA 98433
These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may not be reproduced, except in full,
without written permission by Professional Service Industries, Inc. Approved Signatory: Donald Miller (S?????pecial Project Manager) Date of Issue: 9/15/2011 CC: DOUG PALMER GARY CARLSON
JOHN BARTHELD KATHY DEGMAN MARY TEXIDOR RICK ADAMS Form No: 18971.V1.00, Report No: FC:0742557-10 (c) 2000-2009 QESTLab by SpectraQEST.com Page 1 of 1 Notes Remarks