FC_0742557-6.rev_1General Field Data Technician: Delbert Spicer Test Date: 8/22/2011 Weather: Partly cloudy Test Results Set No. Specimens Made Ticket Time Batched Time Unloaded Cubic Yards Placed Slump
(in) Air Temp. (°F) Concrete Temp. (°F) 0742557-6-C1 4 584503 12:25 01:36 11.0 4.50 71 79 Location & Remarks Set No. Location General Location: Perimeter/spread footings 0742557-6-C1
North west corner Mix Data Set No. Supplier Mix Design Strength (psi) 0742557-6-C1 Holroyd 5051F25-3000 3000 Concrete Field Report Professional Service Industries, Inc. 10025 South Tacoma
Way, #H1 Tacoma, WA 98499 Phone: (253) 589-1804 Fax: (253) 589-2136 Report No: FC:0742557-6 Issue No: 1 Project: AMERICAS CREDIT UNION YELM, WA Client: MERIT COMPANY NW 3020 SOUTH 96TH
STREET LAKEWOOD, WA 98499 These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may not be
reproduced, except in full, without written permission by Professional Service Industries, Inc. Appr?????oved Signatory: Donald Miller (Special Project Manager) Date of Issue: 8/25/2011
CC: DOUG PALMER GARY CARLSON JOHN BARTHELD KATHY DEGMAN MARY TEXIDOR RICK ADAMS Form No: 18971.V1.00, Report No: FC:0742557-6 (c) 2000-2009 QESTLab by SpectraQEST.com Page 1 of 1 Remarks
Sampled from Revolving Drum Truck Mixer (ASTM C 172, 5.2.3) Notes