Loading...
FC_0742557-8.rev_1General Field Data Technician: Cody Pinkley Test Date: 8/25/2011 Weather: Clear Test Results Set No. Specimens Made Ticket Time Batched Cubic Yards Placed Slump (in) Air Temp. (°F) Concrete Temp. (°F) 0742557-8-C1 4 558133 01:47 11.0 5.00 87 76 Location & Remarks Set No. Location General Location: Stem wall concrete placement of top of footing 0742557-8-C1 Please refer to general location Mix Data Set No. Supplier Mix Design Strength (psi) 0742557-8-C1 Holroyd 5051F25-4000 4500 Concrete Field Report Professional Service Industries, Inc. 10025 South Tacoma Way, #H1 Tacoma, WA 98499 Phone: (253) 589-1804 Fax: (253) 589-2136 Report No: FC:0742557-8 Issue No: 1 Project: AMERICAS CREDIT UNION YELM, WA Client: MERIT COMPANY NW 3020 SOUTH 96TH STREET LAKEWOOD, WA 98499 These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may not be reproduced, except in full, without written permission by Professional Service Industries, Inc?????. Approved Signatory: Donald Miller (Special Project Manager) Date of Issue: 8/29/2011 CC: DOUG PALMER GARY CARLSON JOHN BARTHELD KATHY DEGMAN MARY TEXIDOR RICK ADAMS Form No: 18971.V1.00, Report No: FC:0742557-8 (c) 2000-2009 QESTLab by SpectraQEST.com Page 1 of 1 Remarks Sampled from Revolving Drum Truck Mixer (ASTM C 172, 5.2.3) Notes