Loading...
FDR_0742557-21.rev_1Testing Details Tested By: Cody Pinkley Date Tested: 12/20/2011 Field Methods: ASTM D 6938 Gauge Type: Troxler Test Mode: Direct Transmission Model Number: 3430 Standard Count: Density: 2433 Serial Number: 37492 Standard Count: Moisture: 703 Proctor Information Sample ID Supplier Material Method MDD (lb/ft³) OMC (%) 0742557-2-S3 Miles Sand and Gravel 2" minus gravel borrow ASTM D 1557 (C) 135.4 8.4 Test Results Test No. Proctor Sample ID Probe Depth (in.) Wet Density (lb/ft³) Moisture Content (%) OMC Var Dry Density (lb/ft³) Comp (%) Comp Spec Results 1 0742557-2-S3 8 142.6 7.4 -1.0 132.8 98.1 ³95 A 2 0742557-2-S3 8 141.2 9.7 +1.3 128.7 95.1 ³95 A 3 0742557-2-S3 8 141.4 6.2 -2.2 133.1 98.3 ³95 A 4 0742557-2-S3 8 141.5 7.0 -1.4 132.2 97.6 ³95 A 5 0742557-2-S3 8 141.5 7.3 -1.1 131.9 97.4 ³95 A 6 0742557-2-S3 8 140.7 7.5 -0.9 130.9 96.7 ³95 A Location General Location: Top course base for back parking lot Test No. Location Material/Layer 1 CB # 1 Subgrade 2 CB#3 Subgrade 3 100' SW of CB#1 Subgrade 4 CB #2 Subgr?????ade 5 50' NE of CB#3 Subgrade 6 100' NE of CB#3 Subgrade Field Density Test Report Professional Service Industries, Inc. 10025 South Tacoma Way, #H1 Tacoma, WA 98499 Phone: (253) 589-1804 Fax: (253) 589-2136 Report No: FDR:0742557-21 Issue No: 1 Project: AMERICAS CREDIT UNION YELM, WA Client: AMERICAS CREDIT UNION PO BOX 33338 FT. LEWIS, WA 98433 These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may not be reproduced, except in full, without written permission by Professional Service Industries, Inc. If a non-compliance appears on this report, to the extent that the reported non-compliance impacts the project, the resolution is outside the PSI scope of engagement. Approved Signatory: Thor Christensen (Project Engineer) Date of Issue: 1/2/2012 CC: DOUG PALMER GARY CARLSON JOHN BARTHELD KATHY DEGMAN MARY TEXIDOR RICK ADAMS Form No: 110244, Report No: FDR:0742557-21 © 2000-2011 QESTLab by SpectraQEST.com Page 1 of 1 Comments OMC = Optimum Moisture Content MDD = Maximum Dry Density A = TEST RESULTS COMPLY WITH SPECIFICATION Legend