Loading...
SIDF_0742557-9_1.rev_1Page 1 of 2 Report No: SIDF:0742557-9/1 Special Inspection Daily Field Report Issue No: 1 Professional Service Industries, Inc. 10025 South Tacoma Way, #H1 Tacoma, WA 98499 Phone: (253) 589-1804 Fax: (253) 589-2136 Project: No: AMERICAS CREDIT UNION YELM WA Client: MERIT COMPANY NW 3020 SOUTH 96TH STREET LAKEWOOD, WA 98499 These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may not be reproduced, except in full, without written permission by Professional Service Industries, Inc. Approved Signatory: Thor Christensen (Project Engineer) Date of Issue: 9/7/2011 CC: DOUG PALMER, GARY CARLSON, JOHN BARTHELD, KATHY DEGMAN, MARY TEXIDOR, RICK ADAMS Date: 9/2/2011 General Contractor: Merit Permits: Yelm Weather: Clear and warm Type of Inspection Performed Reinforced Concrete Structural Masonry High Strength Bolting Fireproofing New Inspection Re-Inspection Reinforcing Steel Soils Welding Other Standby Time: Field Observations????? & Comments Special Inspection Continuous Periodic Location(s)/Item(s): BLDG slab subgrade and spread footings at grids L/4 & 7(pg#1) and re-tests (pag#2) Referenced Details/Drawings: Foundation section of the general structrual notes as applicable. Remarks: PSI on site for in place density tests of BLDGS slab subgrade, backfill of trenches, the spread footings which were excavated too deep and backfilled, and for previous failing tests at drive thru area BTWN the storm sewer manholes. See PSI report FR#074255-, tests #4 & #5. To the best of PSI’s knowledge, the work inspected to the approved construction documents are: Conforming Non-Conforming Inspector: Joe Allen Inspector Cert No.: SI 01187 Jobsite Representative: Page 2 of 2 Report No: SIDF:0742557-9/1 Special Inspection Daily Field Report Issue No: 1 Professional Service Industries, Inc. 10025 South Tacoma Way, #H1 Tacoma, WA 98499 Phone: (253) 589-1804 Fax: (253) 589-2136 Project: No: AMERICAS CREDIT UNION YELM WA Client: MERIT COMPANY NW 3020 SOUTH 96TH STREET LAKEWOOD, WA 98499 These test results apply only to the specific locations and materials noted and may not represent any other locations or elevations. This report may not be reproduced, except in full, without written permission by Professional Service Industries, Inc. Approved Signatory: Thor Christensen (Project Engineer) Date of Issue: 9/7/2011 CC: DOUG PALMER, GARY CARLSON, JOHN BARTHELD, KATHY DEGMAN, MARY TEXIDOR, RICK ADAMS Date: 9/2/2011 General Contractor: Merit Permits: Yelm Weather: Clear and warm Type of Inspection Performed Reinforced Concrete Structural Masonry High Strength Bolting Fireproofing New Inspection Re-Inspection Reinforcing Steel Soils Welding Other Standby Time: Field Observations & Comments Special Inspection Continuous Periodic Location(s)/Item(s): The BLDGS under vault slab and spread FTGS at grids L/4 & 7 Referenced Details/Drawings: The concrete section of the general structrual notes as appliable and to items listed below. Remarks: 1. Concrete-The slab and footings formwork appears to be tight, plumb, clean and free of debris. The concrete was placed to ACI standards. 2. Slab re-steel-The slabs footings re-steel, corner bars, slab dowels and WWF to DET 16/S2.2. The re-steel and concrete placed over a vapor barrier. 3. Spread FTGS re-steel to foundation plan and footing schedule on S2.1. To the best of PSI’s knowledge, the work inspected to the approved construction documents are: Conforming Non-Conforming Inspector: Joe Allen Inspector Cert No.: SI 01187 Jobsite Representative: